805CM3048CNCColumBidSet_Bk_03.pdf
PDF 3 MB Posted
- Solicitation number
- 36C78625B0029
About this file
These are architectural engineering drawings for the Calverton National Cemetery Columbarium Improvements project, specifically detailing existing conditions and restoration elevations for Columbarium H. The drawings, numbered CS108-CS110, show multiple wall elevations (Walls 5A-8A) with photographic and technical representations of the columbarium structures. The documents include restoration notes indicating requirements for cleaning, joint treatment, and preservation of existing infrastructure. The drawings are part of bid documents for the U.S. Department of Veterans Affairs, prepared by The LA Group, with a project issue date of March 25, 2025, and relate to project number 805CM3048 located in Suffolk County, New York. The technical drawings provide detailed visual and technical specifications for the restoration and improvement of the columbarium walls, including precise elevation views, material annotations, and preservation instructions.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM H EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 7
CS108
9 of 99LTM BMD
COLUMBARIUM H - WALL 5A ELEVATION2 COLUMBARIUM H - WALL 5B ELEVATION3
COLUMBARIUM H - WALL 5C ELEVATION4 COLUMBARIUM H - WALL S5.1 ELEVATION5Scale: 1" = 5'
COLUMBARIUM H KEY1
CS108
CS108
CS108
CS108
2 / D
2 / D
WALL 6
W
ALL 7
W
ALL 4
W
ALL 5
W
ALL 8
WALL 6
WALL 5
2 / D
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE
DETAIL 1/CS501
D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.
SEE SPECIFICATIONS.
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 10/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. NOT APPLICABLE IN COLUMBARIUM H
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. NOT APPLICABLE IN COLUMBARIUM H
8. PITTED AND SPALLING CONCRETE FLATWORK
EXISTING CONDITIONS NOTES:
3 / C
1 / B (ALL JOINTS
IN ELEVATION)
1 / B (ALL JOINTS
IN ELEVATION)
1 / B (ALL JOINTS
IN ELEVATION)
5 / G
5 / G
1 / B (ALL JOINTS
IN ELEVATION)
2 / D
REMOVE AND SALVAGE BENCH TO ALLOW FOR
RESTORATION WORK. BENCH TO BE STORED AND
PROTECTED IN A SECURE LOCATION DESIGNATED
BY THE CEMETERY UNTIL REINSTALLATION
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
A
H
PROTECT EXISTING
PAVEMENT TO
REMAIN, TYP.
LEGEND:
REMOVE AND REPLACE CONCRETE FLATWORK
REMOVE AND REPLACE PRECAST CONCRETE CAP
A
A
H
1 & 3
CS501
CS500
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM H EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 8
CS109
10 of 99LTM BMD
COLUMBARIUM H - WALL 6A ELEVATION2 COLUMBARIUM H - WALL 6B ELEVATION3
COLUMBARIUM H - WALL S6 ELEVATION4 COLUMBARIUM H - WALL S7.1 ELEVATION5Scale: 1" = 5'
COLUMBARIUM H KEY1
CS109
COLUMBARIUM H - BACK OF WALL 7 ELEVATION6
CS109
CS109
CS109
2 / D
2 / D
5 / G
2 / D
WALL 6
W
ALL 7
W
ALL 4
W
ALL 5
W
ALL 8
WALL 6
WALL 5
2 / D
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE
DETAIL 1/CS501
D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.
SEE SPECIFICATIONS.
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 10/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. NOT APPLICABLE IN COLUMBARIUM H
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. NOT APPLICABLE IN COLUMBARIUM H
8. PITTED AND SPALLING CONCRETE FLATWORK
EXISTING CONDITIONS NOTES:
1 / B (ALL JOINTS
IN ELEVATION)
1 / B (ALL JOINTS
IN ELEVATION)
A
1 / B (ALL JOINTS
IN ELEVATION)
1 / B (ALL JOINTS
IN ELEVATION)
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
CS109
8 / H
PROTECT EXISTING
PAVEMENT TO
REMAIN, TYP.
LEGEND:
REMOVE AND REPLACE CONCRETE FLATWORK 3
CS500
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
SUFFOLK COUNTY, NEW YORK
805CM3048
MARCH 25, 2025
U.S. Department of Veterans Affairs
STAMP
Revisions: Date:
Drawing Title
Approved:
Phase
Building Number
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CALVERTON NATIONAL CEMETERY
COLUMBARIUM IMPROVEMENTS
ARCHITECT / ENGINEER OF RECORD: Office of Construction and Facilities Management
BID DOCUMENTS
INTEGRITY FEDERAL SERVICES /
THE LA GROUP JOINT VENTURE
Integrity Federal Services 148 S. Queen Street, Suite 350 Martinsburg
WV 25401
(304)-725-8456
The LA Group 40 Long Alley Saratoga Springs
NY 12866
(518)-587-8100
COLUMBARIUM H EXISTING CONDITIONS
/ RESTORATION ELEVATIONS - SHEET 9
CS110
11 of 99LTM BMD
COLUMBARIUM H - WALL 7A ELEVATION2 COLUMBARIUM H - WALL 7B ELEVATION3
COLUMBARIUM H - WALL S8 ELEVATION4 COLUMBARIUM H - WALL 8A ELEVATION5Scale: 1" = 5'
COLUMBARIUM H KEY1
CS110
CS110
CS110
CS110
2 / D 2 / D
5 / G
2 / D
WALL 6
W
ALL 7
W
ALL 8
WALL 6
WALL 8
WALL 8
W
ALL 8
W
ALL 9
WALL 9
W
ALL 9
A. REMOVE AND RESET PRECAST PANELS. SEE DETAIL 10/CS500 AND
SPECIFICATIONS. INSPECT ANCHORAGE AT TIME OF REMOVAL. ALL
PANELS TO BE CLEANED. SEE SPECIFICATIONS.
B. REMOVE AND REPLACE JOINT SEALANT IF PANELS REMAINING IN
PLACE, NEW SEALANT IF PANELS TO BE REPLACED. SEE
SPECIFICATIONS.
C. REMOVE AND REPLACE WITH NEW PRECAST CONCRETE CAP. SEE
DETAIL 1/CS501
D. REMOVE AND REPLACE JOINT SEALANT AT CRACKED CAP JOINTS.
SEE SPECIFICATIONS.
E. CLEANING: ALL WALLS TO BE CLEANED OF MOLD AND RUST. POWER
WASHING IS PROHIBITED AND CLEANING IS WITH MILD DETERGENT
PER SPECIFICATIONS.
F. REMOVE AND RESET CAP. SEE DETAIL 1/CS501
G. REMOVE CRACKED PANEL AND REPLACE WITH NEW PANEL. SEE
DETAIL 10/CS500
H. REMOVE AND REPLACE CONCRETE PAVEMENT. SEE DETAIL 3/CS500
I. NOT APPLICABLE IN COLUMBARIUM H
RESTORATION NOTES:
1. FAILING PANEL JOINT SEALANT, TYP.
2. FAILING COPING JOINT SEALANT, TYP.
3. CRACKED PRECAST CONCRETE CAP, TYP.
4. STAINED PRECAST CONCRETE PANELS, TYP.
5. CRACKED PRECAST CONCRETE WALL PANELS, TYP.
6. ENTRY WALL PANELS NOT FIRMLY ATTACHED, TYP.
7. NOT APPLICABLE IN COLUMBARIUM H
8. PITTED AND SPALLING CONCRETE FLATWORK
EXISTING CONDITIONS NOTES:
1 / B (ALL JOINTS
IN ELEVATION)
1 / B (ALL JOINTS
IN ELEVATION)
2 / D
1 / B (ALL JOINTS
IN ELEVATION)
1 / B (ALL JOINTS
IN ELEVATION)
NOTE: ALL WALLS ON THIS SHEET TO
RECEIVE CLEANING (E)
LEGEND:
REMOVE EX. VEGETATION & MULCH. NEW GRAVEL
& DECORATIVE STONE PER SPECIFICATIONS
CS501
| 09_CS108_COLUMBARIUM H RESTORATION-H-7 |
| Sheets and Views |
| H-7 |
| 10_CS109_COLUMBARIUM H RESTORATION-H-8 |
| Sheets and Views |
| H-8 |
| 11_CS110_COLUMBARIUM H RESTORATION-H-9 |
| Sheets and Views |
| H-9 |
File details come from the government source that posted it. Updated .