A312r1.pdf

PDF 394 KB Posted

Attached to
Crownpoint Staff Quarters Replacement Federal contract opportunity
Solicitation number
75H70124R00004
Issued by
Department of Health and Human Services Indian Health Service

About this file

This notice solicits proposals for construction services to replace staff quarters at the Crownpoint Healthcare Facility in Crownpoint, New Mexico. The scope of work includes demolishing twenty-five existing homes and constructing three single-family homes, six quadplex multi-family homes, and three duplex multi-family homes to provide thirty-three new housing units total. The contract value is anticipated to exceed $10 million. Interested parties must register in the System for Award Management and may attend an optional site visit on November 14, 2023. Proposals are due by a date specified in the solicitation documents. The award will be a firm fixed-price contract determined by lowest price technically acceptable evaluation. The Department of Health and Human Services Indian Health Service will administer this contract to replace substandard housing and meet increased staffing needs at the Crownpoint Healthcare Facility in Crownpoint, New Mexico.

View the file

Other files for this federal contract opportunity

Other files attached to Crownpoint Staff Quarters Replacement, newest first.
File Type Posted
B05 Amend A00006.pdf PDF
NM20240002.pdf PDF
A001r2.pdf PDF
A601r1.pdf PDF
A103r2.pdf PDF
B05 Amend A00005.pdf PDF
B05 Amend A00004.pdf PDF
A001r1.pdf PDF
A124r1.pdf PDF
B05 Amend A00004.pdf PDF
B05 Amend A00003.pdf PDF
B01 Attachment J11 - CPSQ SITEWORK PHASING C004.pdf PDF
B01 Attachment J10 - Crownpoint Staff Quarters Geotechnical Report.pdf PDF
B05 Amend A00002.pdf PDF
B05 Amend A00001.pdf PDF
B01 Attachment J07 Subcontracting Plan.docx DOCX document
B01 Attachment J05 Location Map.pdf PDF
B01 Attachment J09 PPQ.docx DOCX document
B01 Attachment J06 CPSQ Hazardous Material Report.pdf PDF
B01 RFP 75H70124R00004.pdf PDF
B01 Attachment J08 Company Specialized Experience Form Construction.docx DOCX document
B01 Attachment J03 CPSQ 100CD Specification.pdf PDF
B01 Attachment J02 CPSQ 100CD Drawings.pdf PDF
B01 Attachment J04 CPSQ Building Demolition LImits.pdf PDF
B01 Attachment J01 WD NM20230002.pdf PDF
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 Level 0"

Roof Plate 9' - 1"

A511 D2

A511 B2

09 29

08 15

09 21

07 61 06 25

C2

A511

1/8" / 1'-0"

07 25

04 01

1 Level 0"

Roof Plate 9' - 1"

Level 1 0"

Roof Plate 9' - 1"

A511 D2

A511 A2

A512 A5

08 13

07 24

07 25

06 24

06 18

06 17

07 32

07 61

06 25

07 62

SIM

C3

A511

07 74

07 25

07 61

07 62

06 25

06 17

07 25 07 33

07 42

09 21

06 25

07 39

07 50

03 19

03 19

01 40

06 17

07 61

07 62

06 25

06 20

A512 B4

06 20 t

Z

TR

I

AR

Da

EC

ni g

UONA,

.A.S.

VERNON

ROSAMOND

ee S d:

ET

I AFIC

ON

.R

EG

I S

TERED ARCH I TEC

T

EXPIRES:

RVI

HP

S

NI

D

C E

I

A

A N

HE TL H SE

E

H

N M E

AR P

T

OF

T

C D

SU

S

A

E

TAE L &H

N

VI

S E R

UM

A

H

A

B

C

D

1 2 3 4 5

1 2 3 4 5

Sheet Number:

Sheet Title:

Checked By:

Drawn By:

Scale:

Project No:

Issue Date:

Consultants:

JOHNSON SMITTHIPONG &

ROSAMOND ASSOCIATES, INC.

5210 E Williams Cir Ste 600 Tucson, AZ 85711

(520) 547-7904 www.jsrarchinc.com

U. S.

DEPARTMENT OF

HEALTH AND

HUMAN SERVICES

INDIAN HEALTH SERVICE

NAVAJO AREA OFFICE

/1

9/

:0 3:

P

M Au to de sk D oc s:

//2 1-

IH

S

C ro w np oi nt

S Q v

/2

1-

A rc h C

PS

Q

C en tra l 2

2.

rv t

1" = 1'-0"

A312

WALL SECTIONS

HARGREAVES

YAZZIE

21-050 2/22/22

100% CD

CROWNPOINT STAFF

QUARTERS

CROWNPOINT, NM 87313

KEYNOTES

KEY # KEYNOTE TEXT

01 40 WALL TYPE "P.1"

03 19 POST-TENSION CABLING. REFERENCE STRUCTURAL.

03 31 POST TENSION CONCRETE SLAB - REFERENCE

STRUCTURAL.

04 01 ANCHORED MASONRY VENEER.

06 17 WOOD TRUSS, REFERENCE STRUCTURAL.

06 18 GLUE-LAMINATED BEAM (PAINTED), REFERENCE

STRUCTURAL.

06 20 2x WOOD BLOCKING.

06 24 2x CRIPPLE WITH 1/2" PLYWOOD BACKING.

06 25 1/2" PLYWOOD SHEATHING.

07 24 CLOSED CELL FOAMED-IN-PLACE INSULATION 4" MIN

(R-24).

07 25 CLOSED CELL FOAMED-IN-PLACE INSULATION 9" MIN

(R-60).

07 32 FIBER-CEMENT SOFFIT.

07 33 FIBER-CEMENT FASCIA.

07 39 METAL COUNTER FLASHING. COLOR TO MATCH METAL

ROOF.

07 42 METAL FLASHING.

07 50 WATER STOP.

07 61 STANDING SEAM METAL ROOF.

07 62 SELF ADHERING HIGH TEMPERATURE

UNDERLAYMENT.

07 74 SEAM MOUNTED SNOW GUARD.

08 13 INSULATED EXTERIOR ENTRY DOOR WITH STORM

DOOR.

08 15 SINGLE CAR GARAGE DOOR.

09 21 ONE-COAT STUCCO.

09 29 5/8" TYPE 'X' GYPSUM BOARD.

1" = 1'-0"A1 WALL SECTION @ GARAGE DOOR

1" = 1'-0"A3 WALL SECTION @ ENTRY DOOR

No. Date Description 1 12.20.23 Revision 1

1" = 1'-0"A4 WALL @ SLAB TRANSITION

OPTION 2

File details come from the government source that posted it. Updated .