About this file

This notice solicits proposals for a firm fixed price construction contract to replace staff quarters in Crownpoint, New Mexico. The Indian Health Service requires demolition of twenty-five existing units and construction of three single-family homes, six quadplex multi-family homes, and three duplex multi-family homes for a total of thirty-three new units. The purpose is to address a shortage of housing for non-local employees at the Crownpoint Healthcare Facility. The project location is Crownpoint, New Mexico. The period of performance is 730 calendar days from notice to proceed. The magnitude of construction is anticipated to exceed $10 million. A pre-proposal site visit will take place on November 14, 2023, with requests to attend due seven days prior. Proposals are due in accordance with Federal Acquisition Regulation Part 36 utilizing the lowest price technically acceptable evaluation method.

View the file

Other files for this federal contract opportunity

Other files attached to Crownpoint Staff Quarters Replacement, newest first.
File Type Posted
NM20240002.pdf PDF
B05 Amend A00006.pdf PDF
A103r2.pdf PDF
B05 Amend A00005.pdf PDF
A001r2.pdf PDF
A601r1.pdf PDF
B05 Amend A00004.pdf PDF
A124r1.pdf PDF
A312r1.pdf PDF
B05 Amend A00004.pdf PDF
B05 Amend A00003.pdf PDF
B01 Attachment J11 - CPSQ SITEWORK PHASING C004.pdf PDF
B01 Attachment J10 - Crownpoint Staff Quarters Geotechnical Report.pdf PDF
B05 Amend A00002.pdf PDF
B05 Amend A00001.pdf PDF
B01 Attachment J07 Subcontracting Plan.docx DOCX document
B01 Attachment J05 Location Map.pdf PDF
B01 Attachment J09 PPQ.docx DOCX document
B01 Attachment J06 CPSQ Hazardous Material Report.pdf PDF
B01 RFP 75H70124R00004.pdf PDF
B01 Attachment J02 CPSQ 100CD Drawings.pdf PDF
B01 Attachment J04 CPSQ Building Demolition LImits.pdf PDF
B01 Attachment J01 WD NM20230002.pdf PDF
B01 Attachment J08 Company Specialized Experience Form Construction.docx DOCX document
B01 Attachment J03 CPSQ 100CD Specification.pdf PDF
Show all 25

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WALL HEIGHT AND RATINGSTUD SIZE

WALL TYPE CONVENTION

.1 - ONE HOUR RATED WALL TO STRUCTURE

.2 - TWO HOUR RATED WALL TO STRUCTURE

.P - NON RATED WALL TO 6" ABOVE HIGHEST

ADJACENT CEILING

.F - NON RATED WALL TO CEILING

.C - CHASE WALL TO CEILING, GYP BD ONE

SIDE

.S - SOUND PARTITION TO CEILING

.G - GARAGE DEMISING WALL DOUBLE STUD

2 - 2x2 WOOD STUD 3 - 2x4 WOOD STUD 4 - 2x4 WOOD STUD 6 - 2x6 WOOD STUD

(ALL SIZES ARE NOMINAL)

4.F

TYPICAL WALL ASSEMBLY NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

REFER TO BUILDING ELEVATIONS FOR INFORMATION ON

LOCATIONS OF ALL CONTROL JOINTS

CONSULT ARCHITECT IF WALL TYPE CLARIFICATION IS NEEDED

PRIOR TO CONSTRUCTING THE WALL

PROVIDE FIRE STOPPING AT ALL PENETRATIONS IN ALL FIRE RATED

WALLS AND CEILINGS.

CONTRACTOR TO PROVIDE BLOCKING UNDER GYPSUM BOARD TO

SUPPORT BATH ACCESSORIES, CABINETRY, WALL HUNG SYSTEMS

FURNITURE, WALL STOPS AND OWNER FURNISHED EQUIPMENT.

PROVIDE MOISTURE RESISTANT GYPSUM BOARD (NON-PAPER) IN

ALL TOILETS AND JANITOR CLOSETS AND BACKER BOARD UNDER

CERAMIC TILE WHERE OCCURS

REFER TO INTERIOR ELEVATIONS FOR INFORMATION ON WALL

FINISHES

ALL WALLS WITH SOUND ATTENUATION BLANKETS ARE DESIGNED

FOR AN STC RATING OF 52. SOUND ATTENUATION BLANKETS ARE A

MINIMUM OF 3 1/2" U.N.O.

PROVIDE ACOUSTIC SEAL AT PERIMETER AND PENETRATION OF ALL

SOUND RATED PARTITIONS AND OTHER CONSTRUCTION AS

REQUIRED.

PROVIDE TYPE " X" GYPSUM BOARD AT ALL LOCATIONS AND

THROUGHOUT.

INTERIOR WALLS:

.1 - SINGLE 2x4 WOOD STUD

.2 - DOUBLE 2x4 WOOD STUD

FINISH:

E - STUCCO/CMU

EXTERIOR WALLS:

INTERIORINTERIOR

WALL TYPE '4.x'

.F = STANDARD FULL HEIGHT WALLS:

.B = STRUCTURAL BEARING OR SHEAR WALL + 1/2 HOUR RATED WALLS:

2x4 WOOD STUDS AT 16" O.C. WITH TYPE "X" GYPSUM BOARD ONE SIDE, FIRE STOP AND SEAL ALL PENETRATIONS TO MAINTAIN THE FIRE RATING

SIM TO U.L. DESIGN NO. U305.

.1=ONE HOUR RATED WALLS:

TYPE "X" GYPSUM BOARD BOTH SIDES, FIRE STOP AND SEAL ALL

PENETRATIONS TO MAINTAIN THE FIRE RATING PER U.L. DESIGN NO. U314.

SOUND BATT INSULATION

2x4 WOOD STUDS @ 24" O.C.

5/8" TYPE 'X' GYPSUM

BOARD BOTH SIDES

INTERIORINTERIOR

WALL TYPE '4.S'

3.5" SOUND BATT INSULATION

2x4 WOOD STUDS @ 24" O.C.

5/8" TYPE 'X' GYPSUM BOARD

BOTH SIDES

INTERIORCHASE

WALL TYPE '4.C'

2x4 WOOD STUDS @ 24" O.C.

5/8" TYPE 'X' GYPSUM

BOARD (ROOM SIDE)

INTERIORINTERIOR

WALL TYPE '6.x'

.F = STANDARD FULL HEIGHT WALLS:

.1=ONE HOUR RATED WALLS:

TYPE "X" GYPSUM BOARD BOTH SIDES, FIRE STOP

AND SEAL ALL PENETRATIONS TO MAINTAIN THE FIRE

RATING PER U.L. DESIGN NO. U314.

2x6 WOOD STUDS @ 24" O.C.

5/8" TYPE 'X' GYPSUM

BOARD BOTH SIDES

INTERIORGARAGE

WALL TYPE '4.G'

DOUBLE 2x4 WOOD STUDS @

24" O.C. STAGGERED

5/8" TYPE 'X' GYPSUM BOARD

8"

SPRAY FOAM INSULATION

SECTION

FLOOR

CEILING

ROOF DECK

SILL SEAL GASKET CONT. AT 1

BASE PLATE (GARAGE SIDE)

CONT SEAL AT ROOF DECK

& WALL

FULL HEIGHT GYPSUM

BOARD (GARAGE SIDE) TAPE

& BED SEAL ALL JOINTS

INTERIOREXTERIOR

WALL TYPE 'E.1'

2x4 WOOD STUDS @ 16" O.C.

5/8" TYPE 'X' GYPSUM BOARD

1/2" PLYWOOD SHEATHING

WEATHER BARRIER

STUCCO FINISH OVER METAL

LATH & 1" RIGID INSULATION

INTERIOREXTERIOR

WALL TYPE 'E.2'

(2) 2x4 WOOD STUDS @ 16" O.C. W/ 1" GAP

5/8" TYPE 'X' GYPSUM BOARD

1/2" PLYWOOD SHEATHING

WEATHER BARRIER

STUCCO FINISH OVER METAL

LATH & 1" RIGID INSULATION

SPRAY FOAM INSULATION

INTERIOR

CEILING

ROOF DECK

SECTIONINTERIOR

8"

PLAN

W.S.P

DOUBLE 2x4 WOOD

STUDS @ 16" O.C.

STAGGERED AT CORE

SHEAR WALL PLATE

W.S.P

5/8" TYPE 'C' GYPSUM

BOARD

5/8" TYPE 'X' GYPSUM

BOARD

2x4 WOOD STUDS @

24" O.C. EACH SIDE

UTILIZE FOR PLUMBING

& ELECTRICAL

.1=ONE HOUR RATED WALLS:

INNER 8" WALL SHALL BE TYPE "C" GYPSUM BOARD

BOTH SIDES, FIRE STOP AND SEAL ALL

PENETRATIONS TO MAINTAIN THE FIRE RATING PER

U.L. DESIGN NO. U341. (NO PENETRATIONS).

STC = 54 PER NGC2198

NOTE: RATED WALLS TO BOTTOM OF ROOF DECK.

OUTER WALLS TO BOTTOM OF TRUSS.

FLOOR

SILL SEAL GASKET CONT.

AT 1 BASE PLATE

FIRE CAULK

1/ 2"

INTERIORINTERIOR

WALL TYPE 'P.5'

2x4 WOOD STUDS @ 16" O.C.

5/8" TYPE 'X' GYPSUM BOARD

1/2" PLYWOOD SHEATHING

VARIES

AS REQUIRED FOR ALIGNMENT

SPRAY FOAM INSULATION

INTERIORCHASE

WALL TYPE '4.W'

2x4 WOOD STUDS @ 24" O.C.

5/8" TYPE 'X' GLASS-MAT

WATER RESISTANT GYPSUM

BOARD (ROOM SIDE)

t

Z

TR

I

AR

Da

EC

ni g

UONA,

.A.S.

VERNON

ROSAMOND

ee S d:

ET

I AFIC

ON

.R

EG

I S

TERED ARCH I TEC

T

EXPIRES:

RVI

HP

S

NI

D

C E

I

A

A N

HE TL H SE

E

H

N M E

AR P

T

OF

T

C D

SU

S

A

E

TAE L &H

N

VI

S E R

UM

A

H

A

B

C

D

1 2 3 4 5

1 2 3 4 5

Sheet Number:

Sheet Title:

Checked By:

Drawn By:

Scale:

Project No:

Issue Date:

Consultants:

JOHNSON SMITTHIPONG &

ROSAMOND ASSOCIATES, INC.

5210 E Williams Cir Ste 600 Tucson, AZ 85711

(520) 547-7904 www.jsrarchinc.com

U. S.

DEPARTMENT OF

HEALTH AND

HUMAN SERVICES

INDIAN HEALTH SERVICE

NAVAJO AREA OFFICE

/1

9/

:0 3:

P

M Au to de sk D oc s:

//2 1-

IH

S

C ro w np oi nt

S Q v

/2

1-

A rc h C

PS

Q

C en tra l 2

2.

rv t

As indicated

A001

WALL TYPES

HARGREAVES

HARGREAVES

21-050 2/22/22

100% CD

CROWNPOINT STAFF

QUARTERS

CROWNPOINT, NM 87313

1" = 1'-0"3.x WALL TYPE 4.x

1" = 1'-0"4.S WALL TYPE 4.S

1" = 1'-0"4.C WALL TYPE 4.C

1" = 1'-0"6.x WALL TYPE 6.x

1" = 1'-0"4.G WALL TYPE 4.G

1" = 1'-0"E.1 WALL TYPE E.1

1" = 1'-0"E.2 WALL TYPE E.2

1" = 1'-0"P.1 WALL TYPE P.1

1" = 1'-0"P.5 WALL TYPE P.5

1" = 1'-0"4.W WALL TYPE 4.W

No. Date Description 1 12.20.23 Revision 1