Section J-13F SFLC Std Spec 6341 Interior Deck Covering.pdf

PDF 522 KB Posted

Attached to
Homeland Security Cutter - Light Icebreaker (HSC-L) Solicitation
Solicitation number
70Z02326R93280004
Issued by
Not on record

About this file

SFLC Standard Specification 6341 – Install Interior Deck Covering Systems

This is a standard specification document issued by the Surface Forces Logistics Center (SFLC) for the Coast Guard that establishes requirements for installing interior deck covering systems on Coast Guard vessels. The specification outlines five authorized deck covering systems: Cosmetic Polymeric Epoxy Resin, Ceramic (Porcelain/Quarry) Tile, Fire-Retardant Tile, Electrical Insulating Sheet, and Carpeting, with corresponding appendices (A-E) providing detailed installation requirements for each type. The specification excludes removable deck covering systems such as electrical matting and anti-fatigue matting.

Installation requirements vary by application method: for new underlayment installations, contractors must remove existing deck coverings, prepare surfaces through power tool cleaning to bare metal for steel or mechanical cleaning for aluminum, apply high-build epoxy coating (5.0-6.0 mils DFT per MIL-PRF-24647 or MIL-PRF-23236), and install epoxy underlayment per MIL-PRF-3135 specifications with waterproof membranes where required. For installations over existing underlayment, contractors prepare surfaces by sanding and installing new coverings without removing the underlying material. The specification mandates compliance with multiple industry standards including ANSI A137.1 (ceramic tile), ASTM F1066 and F1700 (vinyl tiles), Fed Spec DDD-C-95 (carpeting), and MIL standards for adhesives, coating systems, and specialized underlayment materials. Table 4-1 provides comprehensive guidance for material selection across interior dry spaces, interior wet spaces, and miscellaneous spaces, with numbered recommendations prioritizing specific systems by application type. Appendix F lists authorized epoxy underlayment products from manufacturers including Illinois Tool Works Inc., Crossfield Products Corp., Kish S.P. Industries, American Hi-Tech Flooring Company, and Epmar Corporation.

View the file

Other files

File Type Posted
SF-30 Amendment A00008.pdf PDF
Attachment 5 - Government Responses to Solicitation Questions_A00008.pdf PDF
RFP_70Z02326R93280004_HSC-L_Conformed_A00008.pdf PDF
Section J-07 Pricing Schedule_A00008.xlsx XLSX spreadsheet
Section J-01 HSC-L System Specification_A00007.pdf PDF
SF-30 Amendment A00007.pdf PDF
RFP_70Z02326R93280004_HSC-L_Conformed_A00007.pdf PDF
Section J-07 Pricing Schedule_A00007.xlsx XLSX spreadsheet
SF-30 Amendment A00006.pdf PDF
Attachment 4 - Government Responses to Solicitation Questions_A00006.pdf PDF
Section J-08_Insurance_Spares_List_A00005.pdf PDF
Section J-13A ATCH 083-001-1 MECL.xlsx XLSX spreadsheet
Section J-13C ATCH 083-004-1 PPL Template.xlsx XLSX spreadsheet
Section J-13E SFLC Std Spec 6310 Requirements for Preservation of Ship Structures.pdf PDF
Section J-13I DD Form 1692 Engineering Change Proposal.pdf PDF
Section J-13J ATCH 086-001 2025-04-04 PROMULGATION FRONT MATTER WITH COPYRIGHT (IPW).pdf PDF
Section J-13L COMDTINST 9085_1D Naval Engineering Computer Aided Design Standards.pdf PDF
Section J-13M COMDTINST M5260_6A Directives System Program.pdf PDF
RFP_70Z02326R93280004_HSC-L_Conformed_A00005.pdf PDF
Section J-02 Design and Readiness Review Requirements and Criteria_A00005.pdf PDF
Section J-13G COMDTINST M5260_6A Management of Scientific and Technical Information (STINFO).pdf PDF
Section J-13N DD Form 1694 Request for Deviation-Waiver.pdf PDF
Section J-53 Sand Chart Template_A00005.xlsx XLSX spreadsheet
Section J-07 Pricing Schedule_A00005.xlsx XLSX spreadsheet
Section J-09A Technical Data Rights Table Instructions.pdf PDF
Section J-09B Tech Data Tables.xlsx XLSX spreadsheet
Section J-11 MIL-HDBK-61B.pdf PDF
Section J-13B ATCH 083-001-2 ESWBS WORKBOOK.xlsx XLSX spreadsheet
Section J-13D ATCH 085-002 3D TDP.pdf PDF
Section J-13H COMDTINST M10360_3D Colors and Coatings Manual.pdf PDF
Section J-13K ATCH 085-005-2 2D TDP.pdf PDF
Section J-52 Outfitting List.pdf PDF
SF-30 Amendment A00004.pdf PDF
Attachment 3 - Government Responses to Solicitation Questions_A00003.pdf PDF
SF-30 Amendment A00003.pdf PDF
RFP_70Z02326R93280004_HSC-L_Conformed_A00003.pdf PDF
SF-30 Amendment A00002.pdf PDF
RFP_70Z02326R93280004_HSC-L_Conformed_A00002.pdf PDF
Attachment 2 - Government Responses to Solicitation Questions_A00002.pdf PDF
Attachment 1 - Government Responses to Solicitation Questions_A00001.pdf PDF
RFP_70Z02326R93280004_HSC-L_Conformed_A00001.pdf PDF
Section J-02 Design and Readiness Review Requirements and Criteria_A00001.pdf PDF
SF-30 Amendment A00001.pdf PDF
RFP_70Z02326R93280004_HSC-L.pdf PDF
Section J-01 PPD-589-001 Detail Spec for Buoy Crane.pdf PDF
Section J-02 Design and Readiness Review Requirements and Criteria.pdf PDF
Section J-12 HSC-L Design Placemat.pdf PDF
Section J-01 HSC-L System Specification ORIG.pdf PDF
Section J-03 Past Performance Questionnaire.docx DOCX document
Section J-07 Pricing Schedule.xlsx XLSX spreadsheet
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SFLC STANDARD SPECIFICATION 6341

2022 1 6341

INSTALL INTERIOR DECK COVERING SYSTEMS

1. SCOPE

1.1 Intent. This standard specification describes the requirements for the Contractor to install interior deck covering systems onboard Coast Guard vessels.

1.2 Appendices.

AUTHORIZED SYSTEM APPENDIX

Cosmetic Polymeric Epoxy Resin A

Ceramic (Porcelain/Quarry) Tile B

Retardant Tile C

Electrical Insulating Sheet D

Carpeting E

Authorized Products List for Epoxy Underlayment F

1.3 Exclusions. This standard specification does not cover installation of electrical matting and anti-fatigue matting, as these are removable deck covering systems - normally cut and laid down (without adhesive) onto existing deck covering systems, where applicable.

2. REFERENCES

COAST GUARD DRAWINGS

None

COAST GUARD PUBLICATIONS

Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), Latest

Revision, Requirements for Preservation of Ship Structures

OTHER REFERENCES

American National Standards Institute (ANSI), A118.10, 2019, Standard Specifications for Load

Bearing, Bonded, Waterproof Membranes for Thin-set Ceramic Tile and Dimension Stone

Installation

American National Standards Institute (ANSI), A137.1, 2019 Standard Specification for Ceramic

Tile

ASTM International (ASTM) F1066, 2018, Tile, Floor, Vinyl Composition

ASTM International (ASTM) F1700, 2020, Solid Vinyl Floor Tile

Federal Specification (Fed Spec) DDD-C-95, Mar 1972, Carpets and Rugs, Wool, Nylon, Acrylic, Modacrylic

MIL-A-21016, Jul 2019, Adhesive, Resilient Deck Covering

MIL-A-24456, Jun 1979, Adhesive for Plastic-Vibration Damping Tile

MIL-A-46106, Jun 1992, Adhesive-Sealants, Silicone, RTV, One-Component

MIL-PRF-32584, Aug 2017, Deck Covering Materials, Monolithic

MIL-PRF-23236, Aug 2009, Coating Systems for Ship Structures

2022 2 6341

MIL-PRF-24647, Jan 2018, Paint System, Anticorrosive and Antifouling, Ship Hull

MIL-PRF-24667, Mar 2018, Coating system, Non-Skid, for Roll or Spray Application

MIL-DTL-15562, May 1996, Matting or Sheet, Floor Covering Insulating for High Voltage

Requirements

MIL-PRF-3135, Sep 2008, Deck Covering Underlay Materials

MIL-PRF-32170, Jun 2006, Deck Tiles, Wear-Resistant

MIL-STD-1623, Jan 2015, Fire Performance Requirements and Approved Specifications for

Interior Finish Materials and Furnishings

Society of Automotive Engineers (SAE) Aerospace Material Specification AMS-S-8802, 2019, Sealing Compound, Temperature-Resistant, Integral Fuel Tanks and Fuel Cell Cavities, High-Adhesion

Tile Council of North America (TCNA), 2020, Handbook for Ceramic, Glass, and Stone Tile

Installation

The Society for Protective Coatings (SSPC) Surface Preparation Specification No.11 (SSPC-SP

11), 2012, Power Tool Cleaning to Bare Metal

3. REQUIREMENTS

3.1 System requirement compliance. The Contractor must comply with the manufacturer's instructions in regards to suitable surface and ambient conditions, in addition to instructions for proper handling, mixing and application of paint, underlay, and deck covering system components.

3.2 Deck covering system installation particulars. The Contractor must refer to the applicable appendix herein, and install the deck covering system(s) designated in the work item. Ensure that each new deck covering system is installed over entire deck surfaces, from bulkhead to bulkhead (butted against permanently installed fixtures and furniture), with the exception of areas under enclosed built-in furniture or under equipment with enclosed foundations, unless otherwise specified in the work item.

3.2.1 Installation over new underlayment. For installation of new deck covering over new underlay, accomplish the following tasks:

3.2.1.1 Decking system removal. Completely remove and dispose of the existing deck covering system, including underlayment and cove base, as applicable, to expose the metal deck.

3.2.1.2 Surface preservation. Prepare and coat the exposed deck surfaces, including deck drains, and vertical bounding surfaces (in way of base coving removal), as applicable; as specified below:

STEEL SURFACES ALUMINUM SURFACES

Power tool cleaning to SSPC-SP 11 (to produce a 1.0 mil anchor profile)

Mechanical cleaning, using power sanders and abrasive sandpaper with no metallic contents, to remove all existing coatings and rust spots, down to bare metal.

3.2.1.2.1 Inspection. Before applying primer coating, perform a visual inspection of the prepared deck surfaces, for signs of corrosion, deterioration, defects, and other abnormalities; submit a CFR.

3.2.1.2.2 Surface coating. Coat all prepared surfaces with one coat, 5.0-6.0 mils DFT of a High Build

Epoxy coating, conforming to MIL-PRF-24647 or MIL-PRF-23236.

2022 3 6341

3.2.1.3 Underlay material.

3.2.1.3.1 General application. Prepare and apply epoxy underlay material over the entire primed deck surfaces, in accordance with Table 3-1 (Underlayment Requirements). See Appendix F (Authorized

Products List for Epoxy Underlayment). Fill in all depressions in the deck, level fair welded seams and deck irregularities, and level off underlay to a minimum thickness of 1/8-inch on the deck. Where necessary, slope the underlay material within an 18-inch radius of deck drains toward the drains. Within coaming and shower stalls, ensure a minimum underlayment thickness of 1/4 inch, with the entire area sloped toward the drain. When installing cosmetic polymeric systems, cove the underlay material up to a maximum height of four inches, to form a coved base over all vertical structures, including stiffeners bounding the deck. Sand underlay, as necessary, to provide a smooth finish.

TABLE 3-1 - UNDERLAYMENT REQUIREMENTS

DECK COVERING SYSTEM

REQUIRED EPOXY

UNDERLAYMENT

NEW INSTALLATIONS/COMPLETE RENEWALS

*All Deck Coverings requiring underlayment MIL-PRF-3135 Type III** or IV, Class 2

REPAIR OF EXISTING SYSTEMS

*Cosmetic Polymeric Epoxy Resin MIL-PRF-3135 Type I, Class 2

Ceramic Tile MIL-PRF-3135 Type I, Class 2

Fire-Retardant Deck Tile MIL-PRF-3135 Type II, Class 2

Carpeting MIL-PRF-3135 Type II, Class 2

Electrical Insulating Sheet MIL-PRF-3135 Type II, Class 2

* No underlayment required for Single Step Cosmetic Polymeric System (MIL-PRF-24613, Type III), unless specified in the work item. System is applied directly to over coated deck surfaces.

** A waterproof membrane must be applied to all Type III underlayment.

3.2.1.3.2 Waterproof membrane. Apply a waterproof membrane meeting the requirements of commercial standard ANSI A118.10 to all MIL-PRF-3135 Type III underlayment. Ensure that the waterproof membrane must be certified by the manufacturer to be compatible with both the underlayment and the installed deck covering. The membrane must be one continuous barrier covering the entire deck, including the cove base 4 inches up each vertical surface and must be installed in accordance with the manufacturer’s instruction.

3.2.1.3.3 Insulating underlayment. When insulating underlayment is specified in a work item, install the underlay material to a thickness of 1/2 to 3/4 inch, in lieu of what is specified above in paragraph

3.2.1.3.1 (General application), to serve as an insulating agent over deck surfaces that are subject to condensation.

NOTE

Insulation underlayment may be used to prevent condensation in certain areas - e.g., above ballast tanks and hot machinery spaces, especially where these decks form the deck tops of living spaces.

3.2.2 Installation over existing underlayment. For installation of deck covering over existing underlayment, accomplish the following tasks:

3.2.2.1 System removal. Remove the existing top deck covering, including cove base (as applicable), to expose, but not damage the existing underlayment.

2022 4 6341

3.2.2.2 Underlayment preparation. Sand the exposed underlayment, to provide a smooth surface, free of irregularities.

3.2.3 Installation over metal substrate – no underlayment required. For installation of deck covering directly over metal substrate, accomplish the following tasks:

3.2.3.1 Remove existing deck covering system, including cove base, to expose the metal deck surfaces.

3.2.3.2 Prepare and coat all exposed deck surfaces, as specified in paragraph 3.2.1.2 (Surface preservation).

3.3 New deck covering protection. After completing the installation of all deck covering systems, the

Contractor must close the work areas to all traffic for as long as is required to prevent damage to the deck coverings during curing period, when applicable. Cover all new deck coverings with suitable covers for the remainder of the availability, to protect against damage or contamination.

NOTE

Deck covering colors/color schemes will be specified in the work item.

4. NOTES

4.1 Guidance for deck covering system selection. Unless otherwise specified in the referencing work item the Contractor may use the following guidance for selecting appropriate interior deck covering systems for spaces onboard Coast Guard vessels.

TABLE 4-1 – DECK COVERING SYSTEMS AUTHORIZED ONBOARD COAST GUARD

VESSELS

INTERIOR DRY SPACES 1, 2, 3, 4, 5, 6

SPACE

MATERIAL

AFFF Station (within coaming) 1. High Build Epoxy 6

Air pressure locks 1. High Build Epoxy 6 with Slip-resistant covering

Ammunition stowage. handling room, ready service room (in traffic and working areas only)

1. High Build Epoxy 6 with Slip-resistant covering

Auxiliary Machinery Spaces 1. High Build Epoxy 6

Bath 1. Wear resistant deck tile

2. Cosmetic polymeric epoxy covering (MIL-PRF-

24613 Type III) 7, 8

DC/Machine Shops and Other Shop Spaces 1. High Build Epoxy 6

Dry Goods Storerooms with Storage Racks Installed 1. High Build Epoxy 6

Electrical/Electronics spaces manned 5 1. Electrical grade sheet

2. Wear resistant deck tile

3. Cosmetic polymeric epoxy covering (MIL-PRF-

24613 Type III) 7, 8

Flag Quarters, CO and XO Quarters, Wardroom and

CPO Lounges

1. Carpet

2. Wear resistant deck tile

2022 5 6341

Labs and Electrical or Electronic Workshops 5 1. Electrical grade sheet

2. Cosmetic polymeric epoxy covering (MIL-PRF-

24613 Type III) 7, 8

3. Wear resistant deck tile

Living and Working Spaces (including offices, berthing, medical spaces, manned storerooms, and passageways serving those spaces)

1. Cosmetic polymeric epoxy covering (MIL-PRF-

24613 Type III) 7, 8

2. Wear resistant deck tile

3. Vinyl composition tile or vinyl tile

Machinery Spaces 1. High Build Epoxy 6

Messing Areas 1. Porcelain tile/Quarry tile

2. Cosmetic polymeric epoxy covering (MIL-PRF-

24613 Type III) 7, 8

3. Wear resistant deck tile

Pilot House and Control Stations, Chart Room. Combat

Information Center. and Ships Store

1. Fatigue reducing deck tile

2. Cosmetic polymeric epoxy covering (MIL-PRF-

24613 Type III) 7, 8

3. Wear resistant deck tile

Shops (walking areas around power tools) 1. High Build Epoxy 6 with Slip-resistant covering

Side Passageways only serving shop spaces (not main passages)

1. High Build Epoxy 6

INTERIOR WET SPACES 1, 2

SPACE MATERIAL

Food Service Spaces (galley, scullery. food serving lines) 9

1. Porcelain/Quarry tile 6” x 6” or 8” x 8”

2. Cosmetic polymeric epoxy covering (MIL-PRF-

24613 Type III) 7, 8

Heads 1. Cosmetic polymeric epoxy covering (MIL-PRF-

24613 Type III) 7, 8

2. Porcelain tile 3” x 3” with waterproof membrane, waterproof epoxy adhesive, and waterproof grout

Laundry Facilities 1. Porcelain/Quarry tile 6” x 6” or 8” x 8” (with water-proof membrane and epoxy adhesive and grout only)

2. Cosmetic polymeric epoxy covering (MIL-PRF-

24613 Type III) 7, 8

Shower Stalls 1. Cosmetic polymeric epoxy covering (MIL-PRF-

24613 Type III) 7, 8

Small Enclosed Spaces Attached to Sanitary Spaces

(e.g. Closets Containing Hot Water Heaters)

1. High Build Epoxy 6

2. Porcelain/Quarry tile

Waste handling, trash compactor, incinerator spaces 1. Porcelain/Quarry tile 6” x 6” or 8” x 8”

Other Wet Working Spaces 1. High Build Epoxy 6 with Slip-resistant covering

MISCELLANEOUS SPACES 2

SPACE MATERIAL

At each side of door with high coaming normally used for continuous traffic, and at the head and foot of ladders.

1. Slip-resistant covering treads (3-treads)

Dry side of doors to weather decks 1. Door mats, portable

Unmanned spaces (wet or dry) 1. High Build Epoxy 6

Working areas around steering gear, electrical machinery (except where rubber matting is installed), and as necessary to ensure safe footing around power tools

1. High Build Epoxy 6 with Slip-resistant covering

2022 6 6341

NOTES:

1. Recommended material systems are numbered sequentially in priority order.

2. Non-skid pads (MIL-PRF-24667, Type XI, Composition PS) must be applied as needed to provide slip resistance.

3. Anti-fatigue matting, such as Nomad Brand matting manufactured by 3M Co. or equal, may be used as needed.

4. Install slip-resistant covering in working areas around machinery where possible lubricant or hydraulic fluid spills or leakage can occur. Application of slip-resistant covering is not required where nonslip plates or gratings are installed.

5. Install electrical grade mats or sheets around all electrical switchboards, operating and servicing areas, electric and electronic equipment as required for prevention of electronic shock.

6. Spaces calling for High Build Epoxy must be prepared and painted in accordance with SFLC

Standard Specification 6310 – “DECKS, METAL INTERIOR AND NON-SKID AREAS / Metal

Decks – No application of deck coverings.”

7. An initial seal coat must be applied to the MIL-PRF-24613 Type III cosmetic polymeric.

8. MIL-PRF-24613 Type I Class 1-3 can be used for repair of existing MIL-PRF-24613 Type I, Class 1-3 cosmetic polymeric systems.

9. Install CRES pan within coaming under steam kettle.

2022 A-1 6341

APPENDIX A

REQUIREMENTS FOR COSMETIC POLYMERIC EPOXY RESIN DECK

COVERING SYSTEMS

A1. SCOPE

A1.1 Intent. This appendix describes the particular requirements for the Contractor to install cosmetic polymeric epoxy resin deck covering systems.

A2. REQUIREMENTS

A2.1 General. The Contractor must mix and prepare the epoxy resin deck covering system designated in the work item, in accordance with manufacture’s recommendations; trowel-apply the prepared system to a thickness as specified below in Table A-1 (Cosmetic Polymeric Epoxy Resin Systems), over deck underlayment or coated deck surfaces, as specified in the work item. Only use Type I, Class 1-3 systems when repairing or renewing a Type I, Class 1-3 systems; do not mix other systems with existing Type I, Class 1 or Class 3 systems.

TABLE A-1 - COSMETIC POLYMERIC RESIN SYSTEMS

EPOXY RESIN TYPE AND CLASS

(MIL-PRF-24613)

THICKNESS (Inch)

Type I, Class 1 (Epoxy, with Broadcast Quartz) 1/8

Type I, Class 2 (Epoxy, with Color Flake Topping) 1/16

Type I, Class 3 (Epoxy, with Marble Chip Aggregate)

1/4

Type III (Single Step – Epoxy Only) 1/8

A2.1.1 Cove base. Include a cove base, using the same epoxy resin deck covering system material, to a maximum height of four inches at all adjacent vertical bounding surfaces, where applicable. .

A2.1.2 Sealing requirements.

A2.1.2.1 Type I system. For “Type I” system installation, seal the system in accordance with the deck covering system manufacturer's instructions.

WARNING

Application of sealer coats in excess of what is recommended by the manufacturer of Type I Cosmetic Polymeric Systems is not in compliance with MIL-PRF-24613, and may also reduce the effectiveness of the systems’ non-slip properties.

2022 A-2 6341

A2.1.2.2 Type III system. For “Type III”/”Single Step” system installation, seal the system in accordance with the deck covering system manufacturer's instructions.

NOTES

1. The “Type III”/”Single Step” Cosmetic Polymeric Systems are formulated as low maintenance systems – not requiring periodic re-sealing. A single seal coat is typically applied per manufacturer’s instructions as part of installation or repair. No additional seal coats may be applied for installation or maintenance.

2. Additional slip resistance can be provided to all cosmetic polymeric resin systems by adding an aggregate (e.g. white aluminum oxide or glass beads) to the final seal coat per the deck covering system manufacturer’s recommendation.

A2.1.2.3 Slip-resistant additives.

A3. NOTES

A3.1 Authorized product list. The following products are authorized for use.

TABLE A-2 – MIL-PRF-24613 QUALIFIED PRODUCTS

TYPE AND

CLASS

MANUFACTURER DESIGNATION SOURCE

Type I, Class 1 Dex-O-Tex Terrazzo "M" Fine Crossfield Products Corp. /

Dex-O-Tex Floor Coverings

Polyspec Twede Epoxy Underlayment Illinois Tool Works Inc.

Polymer Technologies

Polyspec Twede Levelite Latex Underlayment Illinois Tool Works Inc.

Polymer Technologies

Stonhard HF I (TM4, BQ4, PR4, QS4) Stoncor Group, Inc.

Stonhard

Type I, Class 2 CF-100 Illinois Tool Works Inc.

Polymer Technologies

American Oceanic Coatings Corp.

Dex-O-Tex Colorflake "M" Crossfield Products Corp./

Dex-O-Tex Floor Coverings

Polyspec Flex Fr Illinois Tool Works Inc.

Polymer Technologies

Polyspec Flor Epoxy Underlayment Illinois Tool Works Inc.

Polymer Technologies

Polyspec Flor Levelite Latex Underlayment Illinois Tool Works Inc.

Polymer Technologies

SS1290 Ultra Lightweight Deco System Epmar Corporation

Type I, Class 3 Dex-O-Tex Terrazzo 'M' Crossfield Products Corp./

Coloron Marine Terrazzo-Plate 101 Kish, S. P. Industries, Inc.

American Oceanic Coatings Corp.

Dex-O-Tex Terracolor Crossfield Products Corp./

2022 A-3 6341

Phoenix Epoxy Two-Step Deck Covering American Hi-Tech Flooring Company

Polyspec Lux Illinois Tool Works Inc.

Polymer Technologies

ST-100 Illinois Tool Works Inc.

Polymer Technologies

American Oceanic Coatings Corp.

Type III Phoenix Epoxy One-Step Deck Covering American Hi-Tech Flooring Company

Dex-O-Tex Terrazo "M" (Quick-Step) Crossfield Products Corp./

Dex-O-Tex Floor Coverings

ST-100 Illinois Tool Works Inc.

American Oceanic Coatings Corp.

2022 B-1 6341

APPENDIX B

REQUIREMENTS FOR CERAMIC TILE DECK COVERING SYSTEMS

B1. SCOPE

B1.1. Intent. This appendix describes the particular requirements for the Contractor to install particular ceramic tile deck covering systems.

B2. REQUIREMENTS

B2.1. General. The Contractor must install the designated ceramic tiles (ANSI A137.1), over deck underlayment or coated deck surfaces, as specified in the work item, in accordance with the TCA

Handbook for Ceramic Tile Installation. Tile sizes are listed in Table B-1.

TABLE B-1 - CERAMIC TILE PARTICULARS

TYPE OF CERAMIC TILE

(ANSI A137.1)

TILE SIZE

(inches)

Quarry Tiles 6 x 6

8 x 8

Porcelain Tiles *3 x 3

**6 x 6 or 8 x 8

* Head Spaces only

**All Other Wet Spaces

B2.1.1. Trim units. Where applicable, install 4-inch high base ceramic tile trim units (bullnosed at the top edge and coved at the bottom edge) at all vertical projections through the deck. Install bullnosed trim units around depressions in the deck, and rounded internal and external matching corner units.

B2.1.2. Grouting. After the tiles have been firmly set in place, prepare and apply a suitable epoxy grout material to fill all joints even with the surface of the tiles.

B2.2. Surface cleanliness. Upon completion of tile installation and grouting, the Contractor must ensure that all tile surfaces are clean and free of grout and other debris.

B3. NOTES

B3.1. Authorized product list. Most major ceramic tile manufacturers provide acceptable products that meet the requirements of ANSI A137.1.

2022 C-1 6341

APPENDIX C

REQUIREMENTS FOR FIRE-RETARDANT DECK TILE COVERING

SYSTEMS

C1. SCOPE

C1.1. Intent. This appendix describes the requirements for the Contractor to install particular fire-retardant deck tile covering systems.

C2. REQUIREMENTS

C2.1. General. The Contractor must install the type of tile deck covering system designated in the work item, and listed in Table C-1 (Flooring System Particulars), secured with suitable adhesive, over deck underlayment or coated deck surfaces, as specified in the work item.

TABLE C-1 - FLOORING SYSTEM PARTICULARS

TILE TYPE ADHESIVE REQUIREMENT

*Vinyl Composition Tile (ASTM F1066) or Vinyl Tile

(ASTM F1700)

Latex Adhesive (MIL-A-21016) – Dry Areas

Epoxy Adhesive (MIL-24456) – Wet and Damp Areas

Wear Resistant Deck Tile (MIL-PRF-32170, Type I, Class 1)

Epoxy Adhesive (MIL-24456) – Wet , Damp, and Dry

Areas

Rubber (Fatigue Reducing) Deck Tile (MIL-PRF-

32170, Type I, Class 2)

Latex Adhesive (MIL-A-21016) – Dry Areas

Epoxy Adhesive (MIL-24456) – Wet and Damp Areas

* Must meet fire performance requirement of MIL-STD 1623.

C2.1.1. Cove base. Install a 4-inch high vinyl cove base molding, or cove up the sheet edges to a maximum height of four inches at all bulkhead boundaries, where applicable.

C2.1.2. Seam sealing. Use a silicone sealer (MIL-A-46106, Type I) or polysulfide sealant (SAE-AMS-S-

8802, Type 2, Class B), to waterproof all seams against bulkheads, stationary furniture, pipes, and other deck fittings. Where weld lines (beads) prevent deck covering from butting tightly against structure, use a suitable caulking compound in place of tile adhesive; paint the caulking to blend with the deck covering or bulkhead (after the caulking compound has skinned over).

C2.1.3. Protective edging. Where an exposed edge fails to butt up against a fitting or bulkhead, install a

1-inch x 0.08-inch stainless steel or brass strip, or a vinyl bevel-edged strip, screwed or cemented to the deck to protect the edge.

C2.2. Adhesion enhancement. Immediately after the deck covering has been cemented to the deck, the

Contractor must thoroughly roll a 150-pound sectional roller over the deck covering to facilitate adhesion.

2022 C-2 6341

C3. NOTES

C3.1. Authorized product list. The following products are authorized for use.

TABLE C-2 – AUTHORIZED PRODUCTS

TILE TYPE MANUFACTURER

DESIGNATION

SOURCE

Vinyl Composition Tile (ASTM

F1066) or Vinyl Tile (ASTM F1700)

No Qualified Products List (QPL) exists for this type of tile. Most major vinyl tile manufacturers provide products that will meet the requirements of the standard.

Wear Resistant Deck Tile (MIL-

PRF-32170, Type I, Class 1)

Stratica® Tiles (discontinued) Amtico International Inc.

Spacia Tiles (temporarily approved for use until the QPL for MIL-PRF-

32170 is repopulated).

Amtico International Inc.

Rubber (Fatigue Reducing) Deck

Tile (MIL-PRF-32170, Type I, Class

2)

Norament 992 And 992 Grano Tiles Nora Systems, Inc.

Freudenberg Bausysteme Kg

TABLE C-3 AUTHORIZED ADHESIVES

ADHESIVE TYPE MANUFACTURER

DESIGNATION

SOURCE

Latex Adhesive (MIL-A-21016) –

Dry Areas

No QPL exists for this type of adhesive. Most major adhesive manufacturers provide products that will meet the requirements of the standard.

Epoxy Adhesive (MIL-24456) –

Wet , Damp, and Dry Areas

Lord 306 Lord Corporation

Chemical Products Division

ML-D2 Illinois Tool Works Inc.

Polymer Technologies

Phillybond TA-30 Illinois Tool Works Inc.

2022 D-1 6341

APPENDIX D

REQUIREMENTS FOR ELECTRICAL INSULATING SHEET SYSTEMS

D1. SCOPE

D1.1. Intent. This appendix describes the particular requirements for the Contractor to install electrical insulating sheet deck covering systems.

D2. REQUIREMENTS

D2.1. General. The Contractor must fit and install new electrical grade sheet confirming to MIL-DTL-

15562, Type I. When specified in the work item, secure with a latex adhesive conforming to MIL-A-

21016, over deck underlayment or coated deck surfaces.

D2.1.1. Cove base. Install a 4-inch high vinyl cove base molding, or cove up the sheet edges to a maximum height of four inches at all bulkhead boundaries.

D2.1.2. Seam sealing. Use a silicone sealer (MIL-A-46106, Type I) or polysulfide sealant (SAE-AMS-S-

8802, Type 2, Class B), to waterproof all seams against bulkheads, stationary furniture, pipes, and other deck fittings. Where weld lines (beads) prevent deck covering from butting tightly against structure, use a suitable caulking compound in place of tile adhesive; paint the caulking to blend with the deck covering or bulkhead (after the caulking compound has skinned over). Ensure that there are no seams within three feet of electrical hazards. Where this is not possible, accomplish one of the following tasks:

Seal seams between sheets or mats with a thermoplastic deck covering such as vinyl sheet, fused chemically, or heat welded or heat fused with a special hot air gun; or

Install a 3-4 inch wide strip of 20 mil thick polyvinyl chloride (PVC) tape, or 1-foot wide strip of the same electrical grade deck covering system under the seams, to prevent a direct path to ground via seams.

D2.1.3. Protective edging. Where an exposed edge fails to butt up against a fitting or bulkhead, install a

1-inch x 0.08-inch stainless steel or brass strip, or a vinyl bevel-edged strip, screwed or cemented to the deck to protect the edge.

D2.2. Adhesion enhancement. Immediately after the deck covering has been cemented to the deck, the

Contractor must thoroughly roll a 150-pound sectional roller over the deck covering to facilitate adhesion.

D3. NOTES

D3.1. Authorized product list. There is no Qualified Products List. Use products that comply with MIL-

DTL-15562, Type I.

2022 E-1 6341

APPENDIX E

REQUIREMENTS FOR CARPETING

E1. SCOPE

E1.1. Intent. This appendix describes the particular requirements for the Contractor to install new carpeting.

E2. REQUIREMENTS

E2.1. General. The Contractor must cut, fit, and install new carpeting meeting or exceeding the requirements specified in Table E-1 (Carpeting Particulars), install the carpet by the tackless procedure or by cementing it to the primed deck with an adhesive as recommended by the carpet manufacturer over deck underlayment or coated deck surfaces, as specified in the work item. No padding must be applied under carpet.

TABLE E-1 - CARPETING PARTICULARS

MATERIAL SPECIFICATION CONSTRUCTION

Wool (With a Velvet Weave, Woven through the Back -

Certified as Meeting the Requirements of Cancelled Fed Spec

DDD-C-95 Type II Class 1,2, or 4; and Conforming to the Fire

Requirements of MIL-STD-1623.

Single Cut Pile (52 Oz. Per Sq. Yd. Pile)

Single Level Loop Pile (42 Oz. Per Sq.

Yd. Pile)

Multilevel Loop Pile - Woven Through

Back (44 Oz. Per Sq. Yd. Pile)

E2.2. Protective edging. The Contractor must install a bright CRES or aluminum strip, where the carpet abuts other deck covering in foot traffic areas

E3. NOTES

E3.1 Carpeting procurement sources. Carpeting approved for installation onboard Coast Guard vessels may be procured from the following sources:

NAME CONTACT INFORMATION

Marine Carpet Sales

800 Albion Road, Columbia, SC 29205

803-254-9970 / Fax: 803-254-9985 http://www.marinecarpetsales.com/marine-carpet-products.cfm

Continental Flooring Company

9319 N. 94th Way, Suite 1000, Scottsdale, AZ 85258

800- 825-1221 / Fax: 866-553-8892 http://www.continentalflooring.com

Baltimore Abby Carpet

6917 Golden Ring Road, Baltimore, MD 21237

443-460-4600 http://baltimore.abbeycarpet.com/ http://www.marinecarpetsales.com/marine-carpet-products.cfm

2022 F-1 6341

APPENDIX F

AUTHORIZED PRODUCTS LIST FOR EPOXY UNDERLAYMENT

F1. SCOPE

F1.1 Intent. The following products are authorized to be used for underlayment and associated adhesives, as discussed in Section 3.2.1.3.

TABLE F-1 MIL-PRF-3135 QUALIFIED PRODUCTS

TYPE AND CLASS * MANUFACTURER

DESIGNATION

SOURCE

Type I, Class 2

3135 Deck Covering Underlay

Material

Kish, S. P. Industries, Inc.

Phoenix Epoxy One-Step Deck

Covering

American Hi-Tech Flooring

Company

STA-CRETE Regular Underlayment

System

Epmar Corporation

Type I, Class 2

Type II, Class 2

EU-100 Illinois Tool Works Inc.

Polymer Technologies

American Oceanic Coatings Corp.

Dex-O-Tex Terrazzo 'M'

Underlayment

Crossfield Products Corp./

Dex-O-Tex Division

Polyspec Clad Epoxy Underlayment Illinois Tool Works Inc.

Polymer Technologies

SS 1280 One-Step Light Weight

Polymer Underlayment

Epmar Corporation

SS1290FC Ultra-Light Weight

Terrazzo

Epmar Corporation

Type I, Class 2

Type II, Class 2

Type III, Class 2

Dex-O-Tex VLW Lightweight

Underlayment

Crossfield Products Corp./

Dex-O-Tex Division

EU-100 Lite Illinois Tool Works Inc.

Polymer Technologies

American Oceanic Coatings Corp.

SS1290FC Ultra Lightweight

Terrazzo/Underlayment

Epmar Corporation

* Two-part polyurethane primers and underlayments are not allowed, even if listed on QPL-3135.

File details come from the government source that posted it. Updated .