Section J-13F SFLC Std Spec 6341 Interior Deck Covering.pdf
PDF 522 KB Posted
- Solicitation number
- 70Z02326R93280004
- Issued by
- Not on record
About this file
SFLC Standard Specification 6341 – Install Interior Deck Covering Systems
This is a standard specification document issued by the Surface Forces Logistics Center (SFLC) for the Coast Guard that establishes requirements for installing interior deck covering systems on Coast Guard vessels. The specification outlines five authorized deck covering systems: Cosmetic Polymeric Epoxy Resin, Ceramic (Porcelain/Quarry) Tile, Fire-Retardant Tile, Electrical Insulating Sheet, and Carpeting, with corresponding appendices (A-E) providing detailed installation requirements for each type. The specification excludes removable deck covering systems such as electrical matting and anti-fatigue matting.
Installation requirements vary by application method: for new underlayment installations, contractors must remove existing deck coverings, prepare surfaces through power tool cleaning to bare metal for steel or mechanical cleaning for aluminum, apply high-build epoxy coating (5.0-6.0 mils DFT per MIL-PRF-24647 or MIL-PRF-23236), and install epoxy underlayment per MIL-PRF-3135 specifications with waterproof membranes where required. For installations over existing underlayment, contractors prepare surfaces by sanding and installing new coverings without removing the underlying material. The specification mandates compliance with multiple industry standards including ANSI A137.1 (ceramic tile), ASTM F1066 and F1700 (vinyl tiles), Fed Spec DDD-C-95 (carpeting), and MIL standards for adhesives, coating systems, and specialized underlayment materials. Table 4-1 provides comprehensive guidance for material selection across interior dry spaces, interior wet spaces, and miscellaneous spaces, with numbered recommendations prioritizing specific systems by application type. Appendix F lists authorized epoxy underlayment products from manufacturers including Illinois Tool Works Inc., Crossfield Products Corp., Kish S.P. Industries, American Hi-Tech Flooring Company, and Epmar Corporation.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SFLC STANDARD SPECIFICATION 6341
2022 1 6341
INSTALL INTERIOR DECK COVERING SYSTEMS
1. SCOPE
1.1 Intent. This standard specification describes the requirements for the Contractor to install interior deck covering systems onboard Coast Guard vessels.
1.2 Appendices.
AUTHORIZED SYSTEM APPENDIX
Cosmetic Polymeric Epoxy Resin A
Ceramic (Porcelain/Quarry) Tile B
Retardant Tile C
Electrical Insulating Sheet D
Carpeting E
Authorized Products List for Epoxy Underlayment F
1.3 Exclusions. This standard specification does not cover installation of electrical matting and anti-fatigue matting, as these are removable deck covering systems - normally cut and laid down (without adhesive) onto existing deck covering systems, where applicable.
2. REFERENCES
COAST GUARD DRAWINGS
None
COAST GUARD PUBLICATIONS
Surface Forces Logistics Center Standard Specification 6310 (SFLC Std Spec 6310), Latest
Revision, Requirements for Preservation of Ship Structures
OTHER REFERENCES
American National Standards Institute (ANSI), A118.10, 2019, Standard Specifications for Load
Bearing, Bonded, Waterproof Membranes for Thin-set Ceramic Tile and Dimension Stone
Installation
American National Standards Institute (ANSI), A137.1, 2019 Standard Specification for Ceramic
Tile
ASTM International (ASTM) F1066, 2018, Tile, Floor, Vinyl Composition
ASTM International (ASTM) F1700, 2020, Solid Vinyl Floor Tile
Federal Specification (Fed Spec) DDD-C-95, Mar 1972, Carpets and Rugs, Wool, Nylon, Acrylic, Modacrylic
MIL-A-21016, Jul 2019, Adhesive, Resilient Deck Covering
MIL-A-24456, Jun 1979, Adhesive for Plastic-Vibration Damping Tile
MIL-A-46106, Jun 1992, Adhesive-Sealants, Silicone, RTV, One-Component
MIL-PRF-32584, Aug 2017, Deck Covering Materials, Monolithic
MIL-PRF-23236, Aug 2009, Coating Systems for Ship Structures
2022 2 6341
MIL-PRF-24647, Jan 2018, Paint System, Anticorrosive and Antifouling, Ship Hull
MIL-PRF-24667, Mar 2018, Coating system, Non-Skid, for Roll or Spray Application
MIL-DTL-15562, May 1996, Matting or Sheet, Floor Covering Insulating for High Voltage
Requirements
MIL-PRF-3135, Sep 2008, Deck Covering Underlay Materials
MIL-PRF-32170, Jun 2006, Deck Tiles, Wear-Resistant
MIL-STD-1623, Jan 2015, Fire Performance Requirements and Approved Specifications for
Interior Finish Materials and Furnishings
Society of Automotive Engineers (SAE) Aerospace Material Specification AMS-S-8802, 2019, Sealing Compound, Temperature-Resistant, Integral Fuel Tanks and Fuel Cell Cavities, High-Adhesion
Tile Council of North America (TCNA), 2020, Handbook for Ceramic, Glass, and Stone Tile
Installation
The Society for Protective Coatings (SSPC) Surface Preparation Specification No.11 (SSPC-SP
11), 2012, Power Tool Cleaning to Bare Metal
3. REQUIREMENTS
3.1 System requirement compliance. The Contractor must comply with the manufacturer's instructions in regards to suitable surface and ambient conditions, in addition to instructions for proper handling, mixing and application of paint, underlay, and deck covering system components.
3.2 Deck covering system installation particulars. The Contractor must refer to the applicable appendix herein, and install the deck covering system(s) designated in the work item. Ensure that each new deck covering system is installed over entire deck surfaces, from bulkhead to bulkhead (butted against permanently installed fixtures and furniture), with the exception of areas under enclosed built-in furniture or under equipment with enclosed foundations, unless otherwise specified in the work item.
3.2.1 Installation over new underlayment. For installation of new deck covering over new underlay, accomplish the following tasks:
3.2.1.1 Decking system removal. Completely remove and dispose of the existing deck covering system, including underlayment and cove base, as applicable, to expose the metal deck.
3.2.1.2 Surface preservation. Prepare and coat the exposed deck surfaces, including deck drains, and vertical bounding surfaces (in way of base coving removal), as applicable; as specified below:
STEEL SURFACES ALUMINUM SURFACES
Power tool cleaning to SSPC-SP 11 (to produce a 1.0 mil anchor profile)
Mechanical cleaning, using power sanders and abrasive sandpaper with no metallic contents, to remove all existing coatings and rust spots, down to bare metal.
3.2.1.2.1 Inspection. Before applying primer coating, perform a visual inspection of the prepared deck surfaces, for signs of corrosion, deterioration, defects, and other abnormalities; submit a CFR.
3.2.1.2.2 Surface coating. Coat all prepared surfaces with one coat, 5.0-6.0 mils DFT of a High Build
Epoxy coating, conforming to MIL-PRF-24647 or MIL-PRF-23236.
2022 3 6341
3.2.1.3 Underlay material.
3.2.1.3.1 General application. Prepare and apply epoxy underlay material over the entire primed deck surfaces, in accordance with Table 3-1 (Underlayment Requirements). See Appendix F (Authorized
Products List for Epoxy Underlayment). Fill in all depressions in the deck, level fair welded seams and deck irregularities, and level off underlay to a minimum thickness of 1/8-inch on the deck. Where necessary, slope the underlay material within an 18-inch radius of deck drains toward the drains. Within coaming and shower stalls, ensure a minimum underlayment thickness of 1/4 inch, with the entire area sloped toward the drain. When installing cosmetic polymeric systems, cove the underlay material up to a maximum height of four inches, to form a coved base over all vertical structures, including stiffeners bounding the deck. Sand underlay, as necessary, to provide a smooth finish.
TABLE 3-1 - UNDERLAYMENT REQUIREMENTS
DECK COVERING SYSTEM
REQUIRED EPOXY
UNDERLAYMENT
NEW INSTALLATIONS/COMPLETE RENEWALS
*All Deck Coverings requiring underlayment MIL-PRF-3135 Type III** or IV, Class 2
REPAIR OF EXISTING SYSTEMS
*Cosmetic Polymeric Epoxy Resin MIL-PRF-3135 Type I, Class 2
Ceramic Tile MIL-PRF-3135 Type I, Class 2
Fire-Retardant Deck Tile MIL-PRF-3135 Type II, Class 2
Carpeting MIL-PRF-3135 Type II, Class 2
Electrical Insulating Sheet MIL-PRF-3135 Type II, Class 2
* No underlayment required for Single Step Cosmetic Polymeric System (MIL-PRF-24613, Type III), unless specified in the work item. System is applied directly to over coated deck surfaces.
** A waterproof membrane must be applied to all Type III underlayment.
3.2.1.3.2 Waterproof membrane. Apply a waterproof membrane meeting the requirements of commercial standard ANSI A118.10 to all MIL-PRF-3135 Type III underlayment. Ensure that the waterproof membrane must be certified by the manufacturer to be compatible with both the underlayment and the installed deck covering. The membrane must be one continuous barrier covering the entire deck, including the cove base 4 inches up each vertical surface and must be installed in accordance with the manufacturer’s instruction.
3.2.1.3.3 Insulating underlayment. When insulating underlayment is specified in a work item, install the underlay material to a thickness of 1/2 to 3/4 inch, in lieu of what is specified above in paragraph
3.2.1.3.1 (General application), to serve as an insulating agent over deck surfaces that are subject to condensation.
NOTE
Insulation underlayment may be used to prevent condensation in certain areas - e.g., above ballast tanks and hot machinery spaces, especially where these decks form the deck tops of living spaces.
3.2.2 Installation over existing underlayment. For installation of deck covering over existing underlayment, accomplish the following tasks:
3.2.2.1 System removal. Remove the existing top deck covering, including cove base (as applicable), to expose, but not damage the existing underlayment.
2022 4 6341
3.2.2.2 Underlayment preparation. Sand the exposed underlayment, to provide a smooth surface, free of irregularities.
3.2.3 Installation over metal substrate – no underlayment required. For installation of deck covering directly over metal substrate, accomplish the following tasks:
3.2.3.1 Remove existing deck covering system, including cove base, to expose the metal deck surfaces.
3.2.3.2 Prepare and coat all exposed deck surfaces, as specified in paragraph 3.2.1.2 (Surface preservation).
3.3 New deck covering protection. After completing the installation of all deck covering systems, the
Contractor must close the work areas to all traffic for as long as is required to prevent damage to the deck coverings during curing period, when applicable. Cover all new deck coverings with suitable covers for the remainder of the availability, to protect against damage or contamination.
NOTE
Deck covering colors/color schemes will be specified in the work item.
4. NOTES
4.1 Guidance for deck covering system selection. Unless otherwise specified in the referencing work item the Contractor may use the following guidance for selecting appropriate interior deck covering systems for spaces onboard Coast Guard vessels.
TABLE 4-1 – DECK COVERING SYSTEMS AUTHORIZED ONBOARD COAST GUARD
VESSELS
INTERIOR DRY SPACES 1, 2, 3, 4, 5, 6
SPACE
MATERIAL
AFFF Station (within coaming) 1. High Build Epoxy 6
Air pressure locks 1. High Build Epoxy 6 with Slip-resistant covering
Ammunition stowage. handling room, ready service room (in traffic and working areas only)
1. High Build Epoxy 6 with Slip-resistant covering
Auxiliary Machinery Spaces 1. High Build Epoxy 6
Bath 1. Wear resistant deck tile
2. Cosmetic polymeric epoxy covering (MIL-PRF-
24613 Type III) 7, 8
DC/Machine Shops and Other Shop Spaces 1. High Build Epoxy 6
Dry Goods Storerooms with Storage Racks Installed 1. High Build Epoxy 6
Electrical/Electronics spaces manned 5 1. Electrical grade sheet
2. Wear resistant deck tile
3. Cosmetic polymeric epoxy covering (MIL-PRF-
24613 Type III) 7, 8
Flag Quarters, CO and XO Quarters, Wardroom and
CPO Lounges
1. Carpet
2. Wear resistant deck tile
2022 5 6341
Labs and Electrical or Electronic Workshops 5 1. Electrical grade sheet
2. Cosmetic polymeric epoxy covering (MIL-PRF-
24613 Type III) 7, 8
3. Wear resistant deck tile
Living and Working Spaces (including offices, berthing, medical spaces, manned storerooms, and passageways serving those spaces)
1. Cosmetic polymeric epoxy covering (MIL-PRF-
24613 Type III) 7, 8
2. Wear resistant deck tile
3. Vinyl composition tile or vinyl tile
Machinery Spaces 1. High Build Epoxy 6
Messing Areas 1. Porcelain tile/Quarry tile
2. Cosmetic polymeric epoxy covering (MIL-PRF-
24613 Type III) 7, 8
3. Wear resistant deck tile
Pilot House and Control Stations, Chart Room. Combat
Information Center. and Ships Store
1. Fatigue reducing deck tile
2. Cosmetic polymeric epoxy covering (MIL-PRF-
24613 Type III) 7, 8
3. Wear resistant deck tile
Shops (walking areas around power tools) 1. High Build Epoxy 6 with Slip-resistant covering
Side Passageways only serving shop spaces (not main passages)
1. High Build Epoxy 6
INTERIOR WET SPACES 1, 2
SPACE MATERIAL
Food Service Spaces (galley, scullery. food serving lines) 9
1. Porcelain/Quarry tile 6” x 6” or 8” x 8”
2. Cosmetic polymeric epoxy covering (MIL-PRF-
24613 Type III) 7, 8
Heads 1. Cosmetic polymeric epoxy covering (MIL-PRF-
24613 Type III) 7, 8
2. Porcelain tile 3” x 3” with waterproof membrane, waterproof epoxy adhesive, and waterproof grout
Laundry Facilities 1. Porcelain/Quarry tile 6” x 6” or 8” x 8” (with water-proof membrane and epoxy adhesive and grout only)
2. Cosmetic polymeric epoxy covering (MIL-PRF-
24613 Type III) 7, 8
Shower Stalls 1. Cosmetic polymeric epoxy covering (MIL-PRF-
24613 Type III) 7, 8
Small Enclosed Spaces Attached to Sanitary Spaces
(e.g. Closets Containing Hot Water Heaters)
1. High Build Epoxy 6
2. Porcelain/Quarry tile
Waste handling, trash compactor, incinerator spaces 1. Porcelain/Quarry tile 6” x 6” or 8” x 8”
Other Wet Working Spaces 1. High Build Epoxy 6 with Slip-resistant covering
MISCELLANEOUS SPACES 2
SPACE MATERIAL
At each side of door with high coaming normally used for continuous traffic, and at the head and foot of ladders.
1. Slip-resistant covering treads (3-treads)
Dry side of doors to weather decks 1. Door mats, portable
Unmanned spaces (wet or dry) 1. High Build Epoxy 6
Working areas around steering gear, electrical machinery (except where rubber matting is installed), and as necessary to ensure safe footing around power tools
1. High Build Epoxy 6 with Slip-resistant covering
2022 6 6341
NOTES:
1. Recommended material systems are numbered sequentially in priority order.
2. Non-skid pads (MIL-PRF-24667, Type XI, Composition PS) must be applied as needed to provide slip resistance.
3. Anti-fatigue matting, such as Nomad Brand matting manufactured by 3M Co. or equal, may be used as needed.
4. Install slip-resistant covering in working areas around machinery where possible lubricant or hydraulic fluid spills or leakage can occur. Application of slip-resistant covering is not required where nonslip plates or gratings are installed.
5. Install electrical grade mats or sheets around all electrical switchboards, operating and servicing areas, electric and electronic equipment as required for prevention of electronic shock.
6. Spaces calling for High Build Epoxy must be prepared and painted in accordance with SFLC
Standard Specification 6310 – “DECKS, METAL INTERIOR AND NON-SKID AREAS / Metal
Decks – No application of deck coverings.”
7. An initial seal coat must be applied to the MIL-PRF-24613 Type III cosmetic polymeric.
8. MIL-PRF-24613 Type I Class 1-3 can be used for repair of existing MIL-PRF-24613 Type I, Class 1-3 cosmetic polymeric systems.
9. Install CRES pan within coaming under steam kettle.
2022 A-1 6341
APPENDIX A
REQUIREMENTS FOR COSMETIC POLYMERIC EPOXY RESIN DECK
COVERING SYSTEMS
A1. SCOPE
A1.1 Intent. This appendix describes the particular requirements for the Contractor to install cosmetic polymeric epoxy resin deck covering systems.
A2. REQUIREMENTS
A2.1 General. The Contractor must mix and prepare the epoxy resin deck covering system designated in the work item, in accordance with manufacture’s recommendations; trowel-apply the prepared system to a thickness as specified below in Table A-1 (Cosmetic Polymeric Epoxy Resin Systems), over deck underlayment or coated deck surfaces, as specified in the work item. Only use Type I, Class 1-3 systems when repairing or renewing a Type I, Class 1-3 systems; do not mix other systems with existing Type I, Class 1 or Class 3 systems.
TABLE A-1 - COSMETIC POLYMERIC RESIN SYSTEMS
EPOXY RESIN TYPE AND CLASS
(MIL-PRF-24613)
THICKNESS (Inch)
Type I, Class 1 (Epoxy, with Broadcast Quartz) 1/8
Type I, Class 2 (Epoxy, with Color Flake Topping) 1/16
Type I, Class 3 (Epoxy, with Marble Chip Aggregate)
1/4
Type III (Single Step – Epoxy Only) 1/8
A2.1.1 Cove base. Include a cove base, using the same epoxy resin deck covering system material, to a maximum height of four inches at all adjacent vertical bounding surfaces, where applicable. .
A2.1.2 Sealing requirements.
A2.1.2.1 Type I system. For “Type I” system installation, seal the system in accordance with the deck covering system manufacturer's instructions.
WARNING
Application of sealer coats in excess of what is recommended by the manufacturer of Type I Cosmetic Polymeric Systems is not in compliance with MIL-PRF-24613, and may also reduce the effectiveness of the systems’ non-slip properties.
2022 A-2 6341
A2.1.2.2 Type III system. For “Type III”/”Single Step” system installation, seal the system in accordance with the deck covering system manufacturer's instructions.
NOTES
1. The “Type III”/”Single Step” Cosmetic Polymeric Systems are formulated as low maintenance systems – not requiring periodic re-sealing. A single seal coat is typically applied per manufacturer’s instructions as part of installation or repair. No additional seal coats may be applied for installation or maintenance.
2. Additional slip resistance can be provided to all cosmetic polymeric resin systems by adding an aggregate (e.g. white aluminum oxide or glass beads) to the final seal coat per the deck covering system manufacturer’s recommendation.
A2.1.2.3 Slip-resistant additives.
A3. NOTES
A3.1 Authorized product list. The following products are authorized for use.
TABLE A-2 – MIL-PRF-24613 QUALIFIED PRODUCTS
TYPE AND
CLASS
MANUFACTURER DESIGNATION SOURCE
Type I, Class 1 Dex-O-Tex Terrazzo "M" Fine Crossfield Products Corp. /
Dex-O-Tex Floor Coverings
Polyspec Twede Epoxy Underlayment Illinois Tool Works Inc.
Polymer Technologies
Polyspec Twede Levelite Latex Underlayment Illinois Tool Works Inc.
Polymer Technologies
Stonhard HF I (TM4, BQ4, PR4, QS4) Stoncor Group, Inc.
Stonhard
Type I, Class 2 CF-100 Illinois Tool Works Inc.
Polymer Technologies
American Oceanic Coatings Corp.
Dex-O-Tex Colorflake "M" Crossfield Products Corp./
Dex-O-Tex Floor Coverings
Polyspec Flex Fr Illinois Tool Works Inc.
Polymer Technologies
Polyspec Flor Epoxy Underlayment Illinois Tool Works Inc.
Polymer Technologies
Polyspec Flor Levelite Latex Underlayment Illinois Tool Works Inc.
Polymer Technologies
SS1290 Ultra Lightweight Deco System Epmar Corporation
Type I, Class 3 Dex-O-Tex Terrazzo 'M' Crossfield Products Corp./
Coloron Marine Terrazzo-Plate 101 Kish, S. P. Industries, Inc.
American Oceanic Coatings Corp.
Dex-O-Tex Terracolor Crossfield Products Corp./
2022 A-3 6341
Phoenix Epoxy Two-Step Deck Covering American Hi-Tech Flooring Company
Polyspec Lux Illinois Tool Works Inc.
Polymer Technologies
ST-100 Illinois Tool Works Inc.
Polymer Technologies
American Oceanic Coatings Corp.
Type III Phoenix Epoxy One-Step Deck Covering American Hi-Tech Flooring Company
Dex-O-Tex Terrazo "M" (Quick-Step) Crossfield Products Corp./
Dex-O-Tex Floor Coverings
ST-100 Illinois Tool Works Inc.
American Oceanic Coatings Corp.
2022 B-1 6341
APPENDIX B
REQUIREMENTS FOR CERAMIC TILE DECK COVERING SYSTEMS
B1. SCOPE
B1.1. Intent. This appendix describes the particular requirements for the Contractor to install particular ceramic tile deck covering systems.
B2. REQUIREMENTS
B2.1. General. The Contractor must install the designated ceramic tiles (ANSI A137.1), over deck underlayment or coated deck surfaces, as specified in the work item, in accordance with the TCA
Handbook for Ceramic Tile Installation. Tile sizes are listed in Table B-1.
TABLE B-1 - CERAMIC TILE PARTICULARS
TYPE OF CERAMIC TILE
(ANSI A137.1)
TILE SIZE
(inches)
Quarry Tiles 6 x 6
8 x 8
Porcelain Tiles *3 x 3
**6 x 6 or 8 x 8
* Head Spaces only
**All Other Wet Spaces
B2.1.1. Trim units. Where applicable, install 4-inch high base ceramic tile trim units (bullnosed at the top edge and coved at the bottom edge) at all vertical projections through the deck. Install bullnosed trim units around depressions in the deck, and rounded internal and external matching corner units.
B2.1.2. Grouting. After the tiles have been firmly set in place, prepare and apply a suitable epoxy grout material to fill all joints even with the surface of the tiles.
B2.2. Surface cleanliness. Upon completion of tile installation and grouting, the Contractor must ensure that all tile surfaces are clean and free of grout and other debris.
B3. NOTES
B3.1. Authorized product list. Most major ceramic tile manufacturers provide acceptable products that meet the requirements of ANSI A137.1.
2022 C-1 6341
APPENDIX C
REQUIREMENTS FOR FIRE-RETARDANT DECK TILE COVERING
SYSTEMS
C1. SCOPE
C1.1. Intent. This appendix describes the requirements for the Contractor to install particular fire-retardant deck tile covering systems.
C2. REQUIREMENTS
C2.1. General. The Contractor must install the type of tile deck covering system designated in the work item, and listed in Table C-1 (Flooring System Particulars), secured with suitable adhesive, over deck underlayment or coated deck surfaces, as specified in the work item.
TABLE C-1 - FLOORING SYSTEM PARTICULARS
TILE TYPE ADHESIVE REQUIREMENT
*Vinyl Composition Tile (ASTM F1066) or Vinyl Tile
(ASTM F1700)
Latex Adhesive (MIL-A-21016) – Dry Areas
Epoxy Adhesive (MIL-24456) – Wet and Damp Areas
Wear Resistant Deck Tile (MIL-PRF-32170, Type I, Class 1)
Epoxy Adhesive (MIL-24456) – Wet , Damp, and Dry
Areas
Rubber (Fatigue Reducing) Deck Tile (MIL-PRF-
32170, Type I, Class 2)
Latex Adhesive (MIL-A-21016) – Dry Areas
Epoxy Adhesive (MIL-24456) – Wet and Damp Areas
* Must meet fire performance requirement of MIL-STD 1623.
C2.1.1. Cove base. Install a 4-inch high vinyl cove base molding, or cove up the sheet edges to a maximum height of four inches at all bulkhead boundaries, where applicable.
C2.1.2. Seam sealing. Use a silicone sealer (MIL-A-46106, Type I) or polysulfide sealant (SAE-AMS-S-
8802, Type 2, Class B), to waterproof all seams against bulkheads, stationary furniture, pipes, and other deck fittings. Where weld lines (beads) prevent deck covering from butting tightly against structure, use a suitable caulking compound in place of tile adhesive; paint the caulking to blend with the deck covering or bulkhead (after the caulking compound has skinned over).
C2.1.3. Protective edging. Where an exposed edge fails to butt up against a fitting or bulkhead, install a
1-inch x 0.08-inch stainless steel or brass strip, or a vinyl bevel-edged strip, screwed or cemented to the deck to protect the edge.
C2.2. Adhesion enhancement. Immediately after the deck covering has been cemented to the deck, the
Contractor must thoroughly roll a 150-pound sectional roller over the deck covering to facilitate adhesion.
2022 C-2 6341
C3. NOTES
C3.1. Authorized product list. The following products are authorized for use.
TABLE C-2 – AUTHORIZED PRODUCTS
TILE TYPE MANUFACTURER
DESIGNATION
SOURCE
Vinyl Composition Tile (ASTM
F1066) or Vinyl Tile (ASTM F1700)
No Qualified Products List (QPL) exists for this type of tile. Most major vinyl tile manufacturers provide products that will meet the requirements of the standard.
Wear Resistant Deck Tile (MIL-
PRF-32170, Type I, Class 1)
Stratica® Tiles (discontinued) Amtico International Inc.
Spacia Tiles (temporarily approved for use until the QPL for MIL-PRF-
32170 is repopulated).
Amtico International Inc.
Rubber (Fatigue Reducing) Deck
Tile (MIL-PRF-32170, Type I, Class
2)
Norament 992 And 992 Grano Tiles Nora Systems, Inc.
Freudenberg Bausysteme Kg
TABLE C-3 AUTHORIZED ADHESIVES
ADHESIVE TYPE MANUFACTURER
DESIGNATION
SOURCE
Latex Adhesive (MIL-A-21016) –
Dry Areas
No QPL exists for this type of adhesive. Most major adhesive manufacturers provide products that will meet the requirements of the standard.
Epoxy Adhesive (MIL-24456) –
Wet , Damp, and Dry Areas
Lord 306 Lord Corporation
Chemical Products Division
ML-D2 Illinois Tool Works Inc.
Polymer Technologies
Phillybond TA-30 Illinois Tool Works Inc.
2022 D-1 6341
APPENDIX D
REQUIREMENTS FOR ELECTRICAL INSULATING SHEET SYSTEMS
D1. SCOPE
D1.1. Intent. This appendix describes the particular requirements for the Contractor to install electrical insulating sheet deck covering systems.
D2. REQUIREMENTS
D2.1. General. The Contractor must fit and install new electrical grade sheet confirming to MIL-DTL-
15562, Type I. When specified in the work item, secure with a latex adhesive conforming to MIL-A-
21016, over deck underlayment or coated deck surfaces.
D2.1.1. Cove base. Install a 4-inch high vinyl cove base molding, or cove up the sheet edges to a maximum height of four inches at all bulkhead boundaries.
D2.1.2. Seam sealing. Use a silicone sealer (MIL-A-46106, Type I) or polysulfide sealant (SAE-AMS-S-
8802, Type 2, Class B), to waterproof all seams against bulkheads, stationary furniture, pipes, and other deck fittings. Where weld lines (beads) prevent deck covering from butting tightly against structure, use a suitable caulking compound in place of tile adhesive; paint the caulking to blend with the deck covering or bulkhead (after the caulking compound has skinned over). Ensure that there are no seams within three feet of electrical hazards. Where this is not possible, accomplish one of the following tasks:
Seal seams between sheets or mats with a thermoplastic deck covering such as vinyl sheet, fused chemically, or heat welded or heat fused with a special hot air gun; or
Install a 3-4 inch wide strip of 20 mil thick polyvinyl chloride (PVC) tape, or 1-foot wide strip of the same electrical grade deck covering system under the seams, to prevent a direct path to ground via seams.
D2.1.3. Protective edging. Where an exposed edge fails to butt up against a fitting or bulkhead, install a
1-inch x 0.08-inch stainless steel or brass strip, or a vinyl bevel-edged strip, screwed or cemented to the deck to protect the edge.
D2.2. Adhesion enhancement. Immediately after the deck covering has been cemented to the deck, the
Contractor must thoroughly roll a 150-pound sectional roller over the deck covering to facilitate adhesion.
D3. NOTES
D3.1. Authorized product list. There is no Qualified Products List. Use products that comply with MIL-
DTL-15562, Type I.
2022 E-1 6341
APPENDIX E
REQUIREMENTS FOR CARPETING
E1. SCOPE
E1.1. Intent. This appendix describes the particular requirements for the Contractor to install new carpeting.
E2. REQUIREMENTS
E2.1. General. The Contractor must cut, fit, and install new carpeting meeting or exceeding the requirements specified in Table E-1 (Carpeting Particulars), install the carpet by the tackless procedure or by cementing it to the primed deck with an adhesive as recommended by the carpet manufacturer over deck underlayment or coated deck surfaces, as specified in the work item. No padding must be applied under carpet.
TABLE E-1 - CARPETING PARTICULARS
MATERIAL SPECIFICATION CONSTRUCTION
Wool (With a Velvet Weave, Woven through the Back -
Certified as Meeting the Requirements of Cancelled Fed Spec
DDD-C-95 Type II Class 1,2, or 4; and Conforming to the Fire
Requirements of MIL-STD-1623.
Single Cut Pile (52 Oz. Per Sq. Yd. Pile)
Single Level Loop Pile (42 Oz. Per Sq.
Yd. Pile)
Multilevel Loop Pile - Woven Through
Back (44 Oz. Per Sq. Yd. Pile)
E2.2. Protective edging. The Contractor must install a bright CRES or aluminum strip, where the carpet abuts other deck covering in foot traffic areas
E3. NOTES
E3.1 Carpeting procurement sources. Carpeting approved for installation onboard Coast Guard vessels may be procured from the following sources:
NAME CONTACT INFORMATION
Marine Carpet Sales
800 Albion Road, Columbia, SC 29205
803-254-9970 / Fax: 803-254-9985 http://www.marinecarpetsales.com/marine-carpet-products.cfm
Continental Flooring Company
9319 N. 94th Way, Suite 1000, Scottsdale, AZ 85258
800- 825-1221 / Fax: 866-553-8892 http://www.continentalflooring.com
Baltimore Abby Carpet
6917 Golden Ring Road, Baltimore, MD 21237
443-460-4600 http://baltimore.abbeycarpet.com/ http://www.marinecarpetsales.com/marine-carpet-products.cfm
2022 F-1 6341
APPENDIX F
AUTHORIZED PRODUCTS LIST FOR EPOXY UNDERLAYMENT
F1. SCOPE
F1.1 Intent. The following products are authorized to be used for underlayment and associated adhesives, as discussed in Section 3.2.1.3.
TABLE F-1 MIL-PRF-3135 QUALIFIED PRODUCTS
TYPE AND CLASS * MANUFACTURER
DESIGNATION
SOURCE
Type I, Class 2
3135 Deck Covering Underlay
Material
Kish, S. P. Industries, Inc.
Phoenix Epoxy One-Step Deck
Covering
American Hi-Tech Flooring
Company
STA-CRETE Regular Underlayment
System
Epmar Corporation
Type I, Class 2
Type II, Class 2
EU-100 Illinois Tool Works Inc.
Polymer Technologies
American Oceanic Coatings Corp.
Dex-O-Tex Terrazzo 'M'
Underlayment
Crossfield Products Corp./
Dex-O-Tex Division
Polyspec Clad Epoxy Underlayment Illinois Tool Works Inc.
Polymer Technologies
SS 1280 One-Step Light Weight
Polymer Underlayment
Epmar Corporation
SS1290FC Ultra-Light Weight
Terrazzo
Epmar Corporation
Type I, Class 2
Type II, Class 2
Type III, Class 2
Dex-O-Tex VLW Lightweight
Underlayment
Crossfield Products Corp./
Dex-O-Tex Division
EU-100 Lite Illinois Tool Works Inc.
Polymer Technologies
American Oceanic Coatings Corp.
SS1290FC Ultra Lightweight
Terrazzo/Underlayment
Epmar Corporation
* Two-part polyurethane primers and underlayments are not allowed, even if listed on QPL-3135.
File details come from the government source that posted it. Updated .