120VAC PANEL
CR-024B-08A
DSS-024-B08B
RXM-024-B08A
DSS-024-B08A
DLT-024-B08A
PS-024-B08A(2)DSS-024-B084 4
PS-024-B16G PS-024-B16B2 2
UP TO
DATA
CENTER
TO OUTSIDE CHILLER
TOWER
CR-024-0426E
RXM-024-0426E
DSS-024-0426E
DLT-024-0426E
PS-024-0426E
A. ALL CABLE FROM REMOVED ESS DEVICES SHALL BE
PULLED BACK TO CLOSET OR NETWORK SWITCH AND
DISCONNECTED.
B. RECYCLE ALL REMOVED CABLE, DO NOT PUT IN
TRASH.
C. ALL SECURITY ESS EQUIPMENT WILL BE REMOVED AS
SHOWN ON DRAWINGS AND TURNED OVER TO FAA
REPRESENTATIVE PM.
D. CONTRACTOR MUST IDENTIFY AND LABEL ALL ESS
CONDUITS BEFORE REMOVAL. THIS MUST BE VERIFIED
BY FAA PM BEFORE ANY ESS CONDUIT REMOVAL.
JOHNSON CONTROLS WILL PERFORM THIS TASK.
E. ALL ESS AND CCTV EQUIPMENT AND WIRE SHALL BE
REMOVED BY JOHNSON CONTROLS.
F. JOE BENJOCK, JOHNSON CONTROLS, WILL BE THE
CONTACT AND DO ALL REMOVAL AND INSTALLATION OF
ESS EQUIPMENT AND CABLING.
G. ELECTRICAL CONTRACTOR WILL PROVIDE ALL
CONDUIT PATHWAY FOR ESS AND TELECOM COPPER
CABLING AND FIBER.
GENERAL NOTES
1. EXISTING EQUIPMENT TO REMAIN
2. MOVE POWER SUPPLIES IN HALLWAY TO EXISTING
TEL/COMM ROOM 0305/B25. RECONNECT ALL CIRCUITS
THAT ARE NOT BEING REMOVED DURING REMODEL.
3. NEW EQUIPMENT
4. DEMO EXISTING EQUIPMENT
5. REMOVE AND REINSTALL EQUIPMENT AFTER
ELEVATOR UPGRADE
6. PIPES AND COVERED CABLE TRAY THAT COME FROM
THE TUNNEL INTO THE BASEMENT HALLWAYS WILL
NOT BE DEMOLISHED.
7. FAA IT PERSONNEL SHALL REMOVE ALL COPPER AND
FIBER FROM DEMO AREAS AS NEEDED.
8. EXISTING GENERATOR AND UPS MONITORS. RELOCATE
TO SMF STORAGE. COORDINATE FINAL LOCATION WITH
USER AND DATA CENTER PERSONNEL.
9. BEFORE REMOVAL, VERIFY AND SCHEDULE WITH DATA
CENTER AND JOHNSON CONTROLS.
10.EXIT ONLY. NO EXTERIOR HARDWARE.
11.DAS EQUIPMENT. COORDINATE FINAL LOCATION AND
CONDUIT SIZE WITH CONTRACTING OFFICER.
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
9:
:2
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
OVERALL BASEMENT DEMOLITION PLAN
RLG
WCM
JWB 533
TD100
TD100
SCALE: 1/16" = 1'-0"
OVERALL BASEMENT DEMOLITION PLAN1
N
0 8' 16' 32'
1/16" = 1'-0"
KEYPLAN
J
J J
J
JJ
J
J
J
J
J
J
J
J
J
J J
J
J
J
J
A. ALL CABLE FROM REMOVED ESS DEVICES SHALL BE
PULLED BACK TO CLOSET OR NETWORK SWITCH AND
DISCONNECTED.
B. RECYCLE ALL REMOVED CABLE, DO NOT PUT IN
TRASH.
C. ALL SECURITY ESS EQUIPMENT WILL BE REMOVED AS
SHOWN ON DRAWINGS AND TURNED OVER TO FAA
REPRESENTATIVE PM.
D. CONTRACTOR MUST IDENTIFY AND LABEL ALL ESS
CONDUITS BEFORE REMOVAL. THIS MUST BE VERIFIED
BY FAA PM BEFORE ANY ESS CONDUIT REMOVAL.
JOHNSON CONTROLS WILL PERFORM THIS TASK.
E. ALL ESS AND CCTV EQUIPMENT AND WIRE SHALL BE
REMOVED BY JOHNSON CONTROLS.
F. JOE BENJOCK, JOHNSON CONTROLS, WILL BE THE
CONTACT AND DO ALL REMOVAL AND INSTALLATION OF
ESS EQUIPMENT AND CABLING.
G. ELECTRICAL CONTRACTOR WILL PROVIDE ALL
CONDUIT PATHWAY FOR ESS AND TELECOM COPPER
CABLING AND FIBER.
GENERAL NOTES
CPS-024-141
C024-02
SSB-024-02
SFP-024-106A
PS-024-106A
SFP-024-106B
PS-024-106B
CR-024-148A
PS-024-148A
RXM-024-148A
DSS-024-148A
GTS
#04
DLT-024-148A
CR-024-148
PS-024-148
RXM-024-148
(2)DSS-024-148
(2)DLT-024-148
CR-024-148F
RXM-024-148F
DSS-024-148F
DLT-024-148F
PS-024-148F
CR-024-148-1-IN
DRS-024-148-1A
CR-024-148-1-OUT
DLX-024-148-1
PS-024-148-1
(2)DSR-024-111
GTS
#05
DSS-024-E110A
DLS-024-E110A
PS-024-E110A
(2)DSS-024-E110B
(2)DLS-024-E110B
PS-024-E110B
DSS-024-E110C
DLS-024-E110C
PS-024-E110C
(2)DSR-024-119(2)DSR-024-1EL
PANEL 1U2A
GTS
#03
CO24-01
GTS
#02
CPS-024-130
(2)DSS-024-N138B
(2)DLS-024-N138B
PS-024-N138B
PB-024-N138A OUT
(2)DSS-024-N138B
(2)DLS-024-N138A
PS-024-N138A
RXM-024-N138A4
PB-024-N138A IN4
ADO-024-N138A
DI-024-02
(2)DSR-024-W138B
(2)DLS-024-W138B
PS-024-W138B
(2)DSR-024-W138A
(2)DLS-024-W138A
PS-024-W138A
(2)DSS-024-130
DLX-024-130
PS-024-130
MFR-024-W130 4
ADO-024-W130
MA-024-W130 IN
MA-024-W130 OUT
DI-024-W130
ADO-024-W130
TD401
TD402
CR-024-130
1. EXISTING EQUIPMENT TO REMAIN
2. MOVE POWER SUPPLIES IN HALLWAY TO EXISTING
TEL/COMM ROOM 0305/B25. RECONNECT ALL CIRCUITS
THAT ARE NOT BEING REMOVED DURING REMODEL.
3. NEW EQUIPMENT
4. DEMO EXISTING EQUIPMENT
5. REMOVE AND REINSTALL EQUIPMENT AFTER
ELEVATOR UPGRADE
6. PIPES AND COVERED CABLE TRAY THAT COME FROM
THE TUNNEL INTO THE BASEMENT HALLWAYS WILL
NOT BE DEMOLISHED.
7. FAA IT PERSONNEL SHALL REMOVE ALL COPPER AND
FIBER FROM DEMO AREAS AS NEEDED.
8. EXISTING GENERATOR AND UPS MONITORS. RELOCATE
TO SMF STORAGE. COORDINATE FINAL LOCATION WITH
USER AND DATA CENTER PERSONNEL.
9. BEFORE REMOVAL, VERIFY AND SCHEDULE WITH DATA
CENTER AND JOHNSON CONTROLS.
10.EXIT ONLY. NO EXTERIOR HARDWARE.
11.DAS EQUIPMENT. COORDINATE FINAL LOCATION AND
CONDUIT SIZE WITH CONTRACTING OFFICER.
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
9:
:2
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
OVERALL FIRST FLOOR DEMOLITION PLAN
RLG
WCM
JWB 534
TD110
TD110N
0 8' 16' 32'
1/16" = 1'-0"
KEYPLAN
SCALE: 1/16" = 1'-0"
OVERALL FIRST FLOOR DEMOLITION PLAN1
J
J
J J
UP
DSS-024-253
DSS-024-201
DSS-024-218
(2)DSS-024-2ELDSS-024-236
4 4
4 4
A. ALL CABLE FROM REMOVED ESS DEVICES SHALL BE
PULLED BACK TO CLOSET OR NETWORK SWITCH AND
DISCONNECTED.
B. RECYCLE ALL REMOVED CABLE, DO NOT PUT IN
TRASH.
C. ALL SECURITY ESS EQUIPMENT WILL BE REMOVED AS
SHOWN ON DRAWINGS AND TURNED OVER TO FAA
REPRESENTATIVE PM.
D. CONTRACTOR MUST IDENTIFY AND LABEL ALL ESS
CONDUITS BEFORE REMOVAL. THIS MUST BE VERIFIED
BY FAA PM BEFORE ANY ESS CONDUIT REMOVAL.
JOHNSON CONTROLS WILL PERFORM THIS TASK.
E. ALL ESS AND CCTV EQUIPMENT AND WIRE SHALL BE
REMOVED BY JOHNSON CONTROLS.
F. JOE BENJOCK, JOHNSON CONTROLS, WILL BE THE
CONTACT AND DO ALL REMOVAL AND INSTALLATION OF
ESS EQUIPMENT AND CABLING.
G. ELECTRICAL CONTRACTOR WILL PROVIDE ALL
CONDUIT PATHWAY FOR ESS AND TELECOM COPPER
CABLING AND FIBER.
GENERAL NOTES
1. EXISTING EQUIPMENT TO REMAIN
2. MOVE POWER SUPPLIES IN HALLWAY TO EXISTING
TEL/COMM ROOM 0305/B25. RECONNECT ALL CIRCUITS
THAT ARE NOT BEING REMOVED DURING REMODEL.
3. NEW EQUIPMENT
4. DEMO EXISTING EQUIPMENT
5. REMOVE AND REINSTALL EQUIPMENT AFTER
ELEVATOR UPGRADE
6. PIPES AND COVERED CABLE TRAY THAT COME FROM
THE TUNNEL INTO THE BASEMENT HALLWAYS WILL
NOT BE DEMOLISHED.
7. FAA IT PERSONNEL SHALL REMOVE ALL COPPER AND
FIBER FROM DEMO AREAS AS NEEDED.
8. EXISTING GENERATOR AND UPS MONITORS. RELOCATE
TO SMF STORAGE. COORDINATE FINAL LOCATION WITH
USER AND DATA CENTER PERSONNEL.
9. BEFORE REMOVAL, VERIFY AND SCHEDULE WITH DATA
CENTER AND JOHNSON CONTROLS.
10.EXIT ONLY. NO EXTERIOR HARDWARE.
11.DAS EQUIPMENT. COORDINATE FINAL LOCATION AND
CONDUIT SIZE WITH CONTRACTING OFFICER.
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
9:
:3
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
OVERALL SECOND FLOOR DEMOLITION
PLAN
RLG
WCM
JWB 535
TD120
TD120N
0 8' 16' 32'
1/16" = 1'-0"
KEYPLAN
OVERALL SECOND FLOOR DEMOLITION PLAN1
DN UP
C024-03
CPS-024-331
SSB-024-03
UP TO
PENTHOUSE
DOWN TO SECOND
FLOOR TELECOM
ROOM
4 4
A. ALL CABLE FROM REMOVED ESS DEVICES SHALL BE
PULLED BACK TO CLOSET OR NETWORK SWITCH AND
DISCONNECTED.
B. RECYCLE ALL REMOVED CABLE, DO NOT PUT IN
TRASH.
C. ALL SECURITY ESS EQUIPMENT WILL BE REMOVED AS
SHOWN ON DRAWINGS AND TURNED OVER TO FAA
REPRESENTATIVE PM.
D. CONTRACTOR MUST IDENTIFY AND LABEL ALL ESS
CONDUITS BEFORE REMOVAL. THIS MUST BE VERIFIED
BY FAA PM BEFORE ANY ESS CONDUIT REMOVAL.
JOHNSON CONTROLS WILL PERFORM THIS TASK.
E. ALL ESS AND CCTV EQUIPMENT AND WIRE SHALL BE
REMOVED BY JOHNSON CONTROLS.
F. JOE BENJOCK, JOHNSON CONTROLS, WILL BE THE
CONTACT AND DO ALL REMOVAL AND INSTALLATION OF
ESS EQUIPMENT AND CABLING.
G. ELECTRICAL CONTRACTOR WILL PROVIDE ALL
CONDUIT PATHWAY FOR ESS AND TELECOM COPPER
CABLING AND FIBER.
GENERAL NOTES
1. EXISTING EQUIPMENT TO REMAIN
2. MOVE POWER SUPPLIES IN HALLWAY TO EXISTING
TEL/COMM ROOM 0305/B25. RECONNECT ALL CIRCUITS
THAT ARE NOT BEING REMOVED DURING REMODEL.
3. NEW EQUIPMENT
4. DEMO EXISTING EQUIPMENT
5. REMOVE AND REINSTALL EQUIPMENT AFTER
ELEVATOR UPGRADE
6. PIPES AND COVERED CABLE TRAY THAT COME FROM
THE TUNNEL INTO THE BASEMENT HALLWAYS WILL
NOT BE DEMOLISHED.
7. FAA IT PERSONNEL SHALL REMOVE ALL COPPER AND
FIBER FROM DEMO AREAS AS NEEDED.
8. EXISTING GENERATOR AND UPS MONITORS. RELOCATE
TO SMF STORAGE. COORDINATE FINAL LOCATION WITH
USER AND DATA CENTER PERSONNEL.
9. BEFORE REMOVAL, VERIFY AND SCHEDULE WITH DATA
CENTER AND JOHNSON CONTROLS.
10.EXIT ONLY. NO EXTERIOR HARDWARE.
11.DAS EQUIPMENT. COORDINATE FINAL LOCATION AND
CONDUIT SIZE WITH CONTRACTING OFFICER.
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
9:
:3
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
OVERALL THIRD FLOOR DEMOLITION PLAN
RLG
WCM
JWB 536
TD130
TD130N
0 8' 16' 32'
1/16" = 1'-0"
KEYPLAN
OVERALL THIRD FLOOR DEMOLITION PLAN1
J J
DN
A. ALL CABLE FROM REMOVED ESS DEVICES SHALL BE
PULLED BACK TO CLOSET OR NETWORK SWITCH AND
DISCONNECTED.
B. RECYCLE ALL REMOVED CABLE, DO NOT PUT IN
TRASH.
C. ALL SECURITY ESS EQUIPMENT WILL BE REMOVED AS
SHOWN ON DRAWINGS AND TURNED OVER TO FAA
REPRESENTATIVE PM.
D. CONTRACTOR MUST IDENTIFY AND LABEL ALL ESS
CONDUITS BEFORE REMOVAL. THIS MUST BE VERIFIED
BY FAA PM BEFORE ANY ESS CONDUIT REMOVAL.
JOHNSON CONTROLS WILL PERFORM THIS TASK.
E. ALL ESS AND CCTV EQUIPMENT AND WIRE SHALL BE
REMOVED BY JOHNSON CONTROLS.
F. JOE BENJOCK, JOHNSON CONTROLS, WILL BE THE
CONTACT AND DO ALL REMOVAL AND INSTALLATION OF
ESS EQUIPMENT AND CABLING.
G. ELECTRICAL CONTRACTOR WILL PROVIDE ALL
CONDUIT PATHWAY FOR ESS AND TELECOM COPPER
CABLING AND FIBER.
GENERAL NOTES
1. EXISTING EQUIPMENT TO REMAIN
2. MOVE POWER SUPPLIES IN HALLWAY TO EXISTING
TEL/COMM ROOM 0305/B25. RECONNECT ALL CIRCUITS
THAT ARE NOT BEING REMOVED DURING REMODEL.
3. NEW EQUIPMENT
4. DEMO EXISTING EQUIPMENT
5. REMOVE AND REINSTALL EQUIPMENT AFTER
ELEVATOR UPGRADE
6. PIPES AND COVERED CABLE TRAY THAT COME FROM
THE TUNNEL INTO THE BASEMENT HALLWAYS WILL
NOT BE DEMOLISHED.
7. FAA IT PERSONNEL SHALL REMOVE ALL COPPER AND
FIBER FROM DEMO AREAS AS NEEDED.
8. EXISTING GENERATOR AND UPS MONITORS. RELOCATE
TO SMF STORAGE. COORDINATE FINAL LOCATION WITH
USER AND DATA CENTER PERSONNEL.
9. BEFORE REMOVAL, VERIFY AND SCHEDULE WITH DATA
CENTER AND JOHNSON CONTROLS.
10.EXIT ONLY. NO EXTERIOR HARDWARE.
11.DAS EQUIPMENT. COORDINATE FINAL LOCATION AND
CONDUIT SIZE WITH CONTRACTING OFFICER.
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
(2)DSS-024-E400C
(2)DSS-024-W400C
DSS-024-N400C
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
9:
:3
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
OVERALL ROOF DEMOLITION PLAN
RLG
WCM
JWB 537
TD140
TD140N
0 8' 16' 32'
1/16" = 1'-0"
KEYPLAN
OVERALL SECURITY ROOF PLAN1
EXISTING ROOM
TD4012
A. ALL CABLE FROM REMOVED ESS DEVICES SHALL BE
PULLED BACK TO CLOSET OR NETWORK SWITCH AND
DISCONNECTED.
B. RECYCLE ALL REMOVED CABLE, DO NOT PUT IN
TRASH.
C. ALL SECURITY ESS EQUIPMENT WILL BE REMOVED AS
SHOWN ON DRAWINGS AND TURNED OVER TO FAA
REPRESENTATIVE PM.
D. JCI MUST IDENTIFY AND LABEL ALL ESS CONDUITS
BEFORE REMOVAL. THIS MUST BE VERIFIED BY FAA PM
BEFORE ANY ESS CONDUIT REMOVAL.
E. ALL ESS EQUIPMENT AND WIRE SHALL BE REMOVED
BY JOHNSON CONTROLS.
F. JOE BENJOCK, JOHNSON CONTROLS, WILL BE THE
CONTACT AND DO ALL REMOVAL AND INSTALLATION
OF ESS EQUIPMENT AND CABLING.
G. ELECTRICAL CONTRACTOR WILL PROVIDE ALL
CONDUIT PATHWAY FOR ESS AND TELECOM COPPER
CABLING AND FIBER.
H. BEFORE REMOVAL, VERFIY AND SCHEDULE WITH DATA
CENTER AND JOHNSON CONTROLS.
I. BEFORE REMOVAL, VERIFY AND SCHEDULE WITH DATA
CENTER AND JOHNSON CONTROLS.
J. BEFORE INSTALLATION OF ANY WALL MOUNTED
EQUIPMENT, COORDINATE WITH FAA IT AND JOHNSON
CONROLS.
GENERAL NOTES
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
8:
:2
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
ENLARGED DEMOLITION PLAN AND
ELEVATIONS
RLG
WCM
JWB 538
TD401
TD401
SCALE:NTS
ENLARGED DEMO PLAN1
SCALE:NTS
ENLARGED DEMO ELEVATION - WEST2
SCALE:NTS
ENLARGED DEMO ELEVATION - SOUTH3
SCALE: NTS
ENLARGED DEMO ELEVATION - PARTIAL EAST & SOUTH4
SHEET KEYNOTES
1. EXISTING SECURITY PANLES TO REMAIN. EQUIPMENT
MUST REMAIN OPERATIONAL DURING DEMOLITION AND
CONSTRUCTION.
2. EXISTING 110 BLOCK TO BE REMOVED.
EXISTING ROOM 115
TD402 23
A. ALL CABLE FROM REMOVED ESS DEVICES SHALL BE
PULLED BACK TO CLOSET OR NETWORK SWITCH AND
DISCONNECTED.
B. RECYCLE ALL REMOVED CABLE, DO NOT PUT IN
TRASH.
C. ALL SECURITY ESS EQUIPMENT WILL BE REMOVED AS
SHOWN ON DRAWINGS AND TURNED OVER TO FAA
REPRESENTATIVE PM.
D. JCI MUST IDENTIFY AND LABEL ALL ESS CONDUITS
BEFORE REMOVAL. THIS MUST BE VERIFIED BY FAA PM
BEFORE ANY ESS CONDUIT REMOVAL.
E. ALL ESS EQUIPMENT AND WIRE SHALL BE REMOVED
BY JOHNSON CONTROLS.
F. JOE BENJOCK, JOHNSON CONTROLS, WILL BE THE
CONTACT AND DO ALL REMOVAL AND INSTALLATION
OF ESS EQUIPMENT AND CABLING.
G. ELECTRICAL CONTRACTOR WILL PROVIDE ALL
CONDUIT PATHWAY FOR ESS AND TELECOM COPPER
CABLING AND FIBER.
H. BEFORE REMOVAL, VERFIY AND SCHEDULE WITH DATA
CENTER AND JOHNSON CONTROLS.
I. BEFORE REMOVAL, VERIFY AND SCHEDULE WITH DATA
CENTER AND JOHNSON CONTROLS.
J. BEFORE INSTALLATION OF ANY WALL MOUNTED
EQUIPMENT, COORDINATE WITH FAA IT AND JOHNSON
CONROLS.
GENERAL NOTES
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
8:
:3
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
ENLARGED DEMO PLAN AND ELEVATIONS
RLG
WCM
JWB 539
TD402
TD402
SCALE: NTS
ENLARGED DEMO PLAN1
SCALE: NTS
ENLARGED DEMO ELEVATION - EAST2
SHEET KEYNOTES
1. EXISTING FIBER TO MANHOLES TO REMAIN.
2. EXISTING DAS SYSTEM. UPDATE BY FAA IT.
SCALE:NTS
ENLARGED DEMO ELEVATION - WEST3
SCALE:NTS
ENLARGED DEMO ELEVATION4
SCALE:NTS
EXISTING EQUIPMENT - ROOM 1155
THREE (3) CATEGORY 6 DATA/VOICE CABLES ON 8P/8C CONNECTORS.
ONE (1) CATEGORY 6 CABLE ON A 8P/8C CONNECTOR FOR WALL PHONE ,MOUNTED @ 48" AFF.
COMMUNICATIONS CABLING SLEEVE OR CONDUIT
TELECOM GROUNDING BAR (TGB)
19"W X 84"H COMMUNICATIONS EQUIPMENT RACK WITH 6"W VERTICAL CABLE MANAGEMENT
CROSS CONNECT
CONDUIT DOWN
CONDUIT UP
COMMUNICATIONS/ELECTRICAL POWER POLE
JUNCTION BOX - 4 11/16" SQ X 2 1/8"D
WALL MOUNTED JUNCTION BOX
TELEVISION - ONE (1) CATEGORY 6 TERMINATED ON A 8P8C CONNECTOR MOUNTED @ 72" AFF. COORDINATE INSTALLATION OF
ADDITIONAL CABLING AND FACEPLATE CONFIGURATION WITH AV PLANS.
8 OUTPUT TAP
J
J
TV
1. ALL COMM/DATA COPPER/FIBER DEMO AND INSTALLATION WILL BE PERFORMED BY THE FAA IT GROUP.
2. ALL CONDUIT PATHWAYS FOR COMM AND SECURITY WILL BE PART OF THE ELECTRICAL CONTRACTORS RESPONSIBILITY.
3. ALL COPPER TERMINATION HARDWARE TO BE 110 STYLE IDC, UNO.
4. TERMINATE ALL CONDUCTORS; NO CABLE SHALL CONTAIN NON TERMINATED ELEMENTS EXCEPT THE 25TH PAIR OF BINDER
GROUPS IN MULTI-PAIR COPPER BACKBONE CABLE. MAKE TERMINATION ONLY AT INDICATED OUTLETS, TERMINALS, CROSS-
CONNECTS AND PATCH PANELS.
5. CABLE MAY NOT BE SPLICED, UNO.
6. MONITOR CABLE PULL TENSION TO ENSURE MANUFACTURER RECOMMENDATION AND INDUSTRY STANDARDS ARE NOT
EXCEEDED.
7. PROVIDE PULL STRING IN ALL EMPTY CONDUIT INNERDUCT. PULL STRING TO BE RATED FOR 200 lbs. IN ALL CONDUIT.
8. PROVIDE PULL BOXES IN CONDUITS NO MORE THAN 100' APART AND PER EVERY 180 DEGREES OF BEND.
9. FIELD COORDINATE LOCATION OF NEW EQUIPMENT IAW APPLICABLE CODES AND FAA STANDARDS DIVISION 27 01/18/2016.
10.MOUNT OUTLET BOXES SAME HEIGHT AS ELECTRICAL OUTLETS UNO.
11.NO CONDULETS OR FITTINGS SHALL BE USED.
12.TELECOMMUNICATIONS AND TELEVISION FACEPLATES SHALL MATCH ELECTRICAL SWITCH AND ELECTRICAL PLATE FINISHES.
13.PROVIDE COVER PLATES FOR ALL UNUSED J-BOX LOCATIONS.
14.ALL SLEEVES AND PENETRATIONS SHALL BE ACOUSTICALLY AND FIRE STOPPED TO MEET WALL AND FLOOR RATING.
15.PROVIDE TWO (2) CATEGORY 6 CABLES TERMINATED ON 8P8C CONNECTORS TO EACH SECURITY PANEL AND WAP LOCATION.
16.MAINTAIN MINIMUM SEPARATION OF 12” WHEN POWER AND COMMUNICATIONS CABLING ARE CO-LOCATED. THIS HAS TO BE
APPROVED BY FAA IT BEFORE INSTALLATION.
17.ALL CABLES SHALL BE RATED FOR THE LOCATION THEY ARE INSTALLED IN.
18.ALL COPPER CAT-6 CABLE/FIBER AND COMMUNICATION EQUIPMENT WILL BE PROVIDED AND INSTALLED BY FAA PERSONNEL
ONLY.
19.ALL CONDUIT PATHWAYS (1" MIN.) FOR WALL MOUNT AND CEILING MOUNT DEVICES SHALL BE PROVIDED BY ELECTRICAL
CONTRACTOR AND SIZED BY THE FAA IT STAFF.
20.ALL WAP AND DAS LOCATIONS AND EQUIPMENT WILL BE PROVIDED AND INSTALLED BY FAA IT STAFF.
ABO ALTERNATIVE BID OPTIONS
ACEG AC EQUIPMENT GROUND
ACS ACCESS CONTROL SYSTEM
AFF ABOVE FINISHED FLOOR
AWG AMERICAN WIRE GAUGE
BCC BACKBONE COPPER CABLE
BCT BONDING CONDUCTOR FOR
TELECOMMUNICATIONS
BKBD BACKBOARD
BSMT BASEMENT
BMS BALANCED MAGNETIC SWITCH
CAT 6 4-PAIR, CATEGORY 6 UTP CABLE
CATV COMMUNITY ANTENNA TELEVISION
CCTV CLOSED CIRCUIT TELEVISION
CD CAMPUS DISTRIBUTOR
CER COMMUNICATIONS EQUIPMENT ROOM
CFCI CONTRACTOR FURNISHED CONTRACTOR
INSTALLED
CLST CLOSET
CMH COMMUNICATIONS MAINTENANCE HOLE
COMM COMMUNICATIONS
CT CABLE TRAY
DAS DISTRIBUTED ANTENNA SYSTEM
DEMO DEMOLITION
DIST DISTRIBUTION
EES EARTH ELECTRODE SYSTEM
EF ENTRANCE FACILITY
EMT ELECTRICAL METALLIC TUBING
ENL EXISTING NEW LOCATION
ER EQUIPMENT ROOM
ETM EXISTING TO MOVE
ETR EXISTING TO REMAIN
ETBR EXISTING TO BE REMOVED
FOC FIBER OPTIC CABLE
GE GROUNDING ELECTRODE
GEC GROUNDING ELECTRODE CONDUCTOR
GFGI GOVERNMENT FURNISHED GOVERNMENT
INSTALLED
GFCI GOVERNMENT FURNISHED CONTRACTOR
INSTALLED
GICF GOVERNMENT INSTALLED CONTRACTOR
FURNISHED
GND GROUND
HDPE HIGH DENSITY POLYETHYLENE
HH HAND HOLE
IAW IN ACCORDANCE WITH
IC INTERMEDIATE CROSS-CONNECT
IDC INSULATION DISPLACEMENT CONNECTOR
IDF INTERMEDIATE DISTRIBUTION FRAME
IDS INTRUSION DETECTION SYSTEM
IMC INTERMEDIATE METAL CONDUIT
JB J-BOX
LAN LOCAL AREA NETWORK
MAX MAXIMUM
MH MAINTENANCE HOLE
MIN MINIMUM
MM MULTIMODE FIBER
MNS MASS NOTIFICATION SYSTEM
MSB MAIN SERVICE BUS
MTD MOUNTED
NEC NATIONAL ELECTRICAL CODE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OSP OUTSIDE PLANT
ONT OPTICAL NETWORK TERMINAL
OLT OPTICAL LINE TERMINAL
TELECOMMUNICATIONS - GENERAL NOTES
TELECOMMUNICATIONS/SPECIAL SYSTEMS ABBREVIATIONS LISTTELECOMMUNICATIONS SYMBOLS
V
M
S
S
S
S
AMP
AUDIO VIDEO SYMBOLS
2/4/8 WAY SPLITTER
2-WAY VIDEO AMPLIFIER
VIDEO EQUALIZER
VIDEO ATTENUATOR
COUPLER
VIDEO AMPLIFIER
VOLUME CONTROL
MICROPHONE
HORN SPEAKER MOUNTED TO WALL OR
STRUCTURE
SPEAKER
SPEAKER PENDANT
SPEAKER WALL
AUDIO AMPLIFIER
HEADEND
WIRELESS ANTENNA
LCD PROJECTOR
1 OUTPUT TAP
2 OUTPUT TAP
4 OUTPUT TAP
W
FLOOR CABINET - 84"H X 30"W X 36"D W/FRONT MOUNTED VERTICAL CABLE MANAGEMENT, UNO.
AV
AUDIO VIDEO OUTLET. 8"X8"X2 1/2"D RECESSED BOX WITH FLUSH
FLANGED SCREW COVER. INSTALL (2) 2" CONDUITS TO ACCESSIBLE
CEILING. MOUNT 18" AFF.
PCU PREMISE CONTROL UNIT
PET PROTECTED ENTRANCE
TERMINAL
POL PASSIVE OPTICAL LAN
PON PASSIVE OPTICAL NETWORK
POP POINT OF PRESENCE
PR PAIR
PT POINT
PTZ PAN, TILT, ZOOM
PVC POLY VINYL CHLORIDE
RM ROOM
RGS/RMC RIGID GALVANIZED STEEL CONDUIT
RU RACK UNIT
SCTP SCREENED TWISTED PAIR
SHT SHEET
SM SINGLEMODE FIBER
STP SHIELD TWISTED PAIR
TBB TELECOM BONDING BACKBONE
TBL TABLE
TGB TELECOM GROUNDING BAR
TMGB TELECOM MAIN GROUNDING BAR
TR TELECOM ROOM
TV TELEVISION
TYP TYPICAL
UL UNDERWRITERS LABORATORY
UM MICROMETERS
UNO UNLESS NOTED OTHERWISE
UTP UNSHIELDED TWISTED PAIR
W/ WITH
WAP WIRELESS ACCESS POINT
ZB ZONE BOX(ES)
FLOOR BOX. # DENOTES NUMBER OF OUTLETS IN BOX. REFER DETAIL 6/TT501
NUMBER OF CATEGORY 6 DATA/VOICE CABLES ON 8P/8C CONNECTORS.
TWO (2) CATEGORY 6 CABLES ON A 8P/8C CONNECTORS
WAP
TWO (2) CATEGORY 6 CABLES ON A 8P/8C CONNECTORS FOR DISTRIBUTED ANTENNA SYSTEM (DAS)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
8:
:3
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
TELECOMMUNICATIONS LEGEND,
ABBREVIATIONS & SYMBOLS
RLG
WCM
JWB 540
T-001
T-001
DN
DN
DN
DN
TV
9 9.9 10 11 11.3 12 12.6 13 13.1 13.6 14 15 16 16.1
P
N
M
L.6
L.1
L
K.6
K
J.3
J
H
MATCHLINE
SEE 1 / TT102
MATCHLINE
SEE 1 / TT102
BREAK ROOM
RR WOMEN
CONFERENCE ROOM
CORRIDOR
OPEN OFFICE
CORRIDOR
OPEN OFFICE
CORRIDOR
OPEN OFFICE
W
M
AT
C H
LI
N
E S
EE
/T T1
ELEC.
W
W
TT401
COMM.
COMPUTER WORK
ROOM
6 6 6
PRIVATE OFFICE
0108A
PHONE ROOM
0108B
PHONE ROOM
0108C
PHONE ROOM
0108D
CONFERENCE ROOM
0108E
6 66
WAP
WAP
WAP
WAP
GENERAL NOTES
A. ALL OFFICES WILL GET 3 CABLES IN EACH WORK
OUTLET.
B. TELECOMMUNICATIONS AND TELEVISION FACEPLATES
SHALL MATCH ELECTRICAL SWITCH AND ELECTRICAL
PLATE FINISHES.
C. PROVIDE COVER PLATES FOR ALL UNUSED J-BOX
LOCATIONS.
D. ALL SLEEVES AND PENETRATIONS SHALL BE
ACOUSTICALLY AND FIRE STOPPED TO MEET WALL
RATING.
E. ALL COMM/DATA COPPER/FIBER INSTALLATION WILL BE
PERFORMED BY THE FAA IT GROUP.
F. ALL CONDUIT PATHWAYS FOR COMM AND SECURITY
WILL BE PART OF THE ELECTRICAL CONTRACTOR'S
RESPONSIBILITY.
G. ALL AREAS WILL RECEIVE NEW COMM DROPS TO
MATCH NEW INFRASTRUCTURE.
H. COMM/DATA OUTLETS IN ACCESS FLOOR SHALL BE
WITHIN FLOOR BOXES.
1. PROVIDE (4) - 4" EMT CONDUITS TO 1ST FLOOR COMM
ROOM 1119B.
2. RELOCATE ALL EXISTING CAT-6 CABLE TO
TELECOM ROOM 0113.
3. PROVIDE PHONE LINE TO NEW ELEVATOR
EQUIPMENT.
4. ALL ELEVATORS SHALL HAVE A SINGLE NEW CAT-6
CABLE TO NEAREST PATCH PANEL LOCATION.
CONNECT TO NEW VOICE SYSTEM.
5. (2) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
6. (4) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR..
7. (5) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
8. (4) - 4" CONDUITS UP TO COMM. ROOM 1305.
9. PROVIDE 1" CONDUIT WITH PULL STRING FROM
NEAREST COMM. ROOM TO JUNCTION BOX FOR
WIRELESS ACCESS POINT.
10.EXTEND EXISTING FIBER RUN FROM 0305 TO NEW
FACP
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
8:
:2
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
BASEMENT TELECOMMUNICATIONS PLAN -
AREA 1
RLG
WCM
JWB 541
TT101
TT101N
KEYPLAN
SCALE: 1/8" = 1'-0"
BASEMENT TELECOMMUNICATIONS PLAN - AREA 11
0 4' 8' 16'
1/8" = 1'-0"
DN
DN
9 9.9 10 11 11.3 12 12.6 13 13.1 13.6 14 15 16 16.1
G
F
E
D
C
B
A
MATCHLINE
SEE 1 / TT101
MATCHLINE
SEE 1 / TT101
CORRIDOR
OPEN OFFICE
ELEV. EQUIP
CORRIDOR
0206 SERVICE ELEV
EXISTING LAB
CORR.
CORRIDOR
EXISTING LOADING
DOCK
EXISTING STAIR
STORAGE
JAN.
RR WOMEN
SECURE STORAGE
SECURE SHREDDER
M
AT
C H
LI
N
E S
EE
/T T1
EXISTING STORAGE
0216RECORD STORAGE
STORAGE
STORAGE
W
WAP
WAP
WAP
GENERAL NOTES
A. ALL OFFICES WILL GET 3 CABLES IN EACH WORK
OUTLET.
B. TELECOMMUNICATIONS AND TELEVISION FACEPLATES
SHALL MATCH ELECTRICAL SWITCH AND ELECTRICAL
PLATE FINISHES.
C. PROVIDE COVER PLATES FOR ALL UNUSED J-BOX
LOCATIONS.
D. ALL SLEEVES AND PENETRATIONS SHALL BE
ACOUSTICALLY AND FIRE STOPPED TO MEET WALL
RATING.
E. ALL COMM/DATA COPPER/FIBER INSTALLATION WILL BE
PERFORMED BY THE FAA IT GROUP.
F. ALL CONDUIT PATHWAYS FOR COMM AND SECURITY
WILL BE PART OF THE ELECTRICAL CONTRACTOR'S
RESPONSIBILITY.
G. ALL AREAS WILL RECEIVE NEW COMM DROPS TO
MATCH NEW INFRASTRUCTURE.
H. COMM/DATA OUTLETS IN ACCESS FLOOR SHALL BE
WITHIN FLOOR BOXES.
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
8:
:3
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
BASEMENT TELECOMMUNICATIONS PLAN -
AREA 2
RLG
WCM
JWB 542
TT102
TT102N
KEYPLAN
SCALE: 1/8" = 1'-0"
BASEMENT TELECOMMUNICATIONS PLAN - AREA 21
SHEET KEYNOTES
1. THIS ROOM SHALL NOT GO OFF THE NETWORK DURING
THE REMODEL. KEEP ALL EXISTING NETWORK AND
POWER LIVE.
2. VERIFY PHONE LINE STAYS ACTIVE AND WORKING AT
ALL TIMES.
3. PROVIDE 1" CONDUIT WITH PULL STRING FROM
NEAREST COMM. ROOM TO JUNCTION BOX FOR
WIRELESS ACCESS POINT.
0.6 0.7 0.8 1 2 3 4 5 6 7 8
G
F
E
D
C
B
A
M
AT
C H
LI
N
E S
EE
/T T1
RR WOMEN
RR WOMEN
EXISTING ELEC
CORRIDOR
EXISTING SPRAY
ROOM
SECURE STORAGE
BREAK ROOM
0310 SECURE SHREDDER
PRINT SHOP
EXISTING BOILER
EXISTING ELEC
EXISTING BATTERY
BACK UP
0308 CORR.
EXISTING TEL/COM
AREA-WAY
ELEC VAULT
RR MEN
W
W
W
W
W
W
W
W
MATCHLINE
SEE 1 / TT104
STORAGE
W 8
SYSTEMS
0322A
8'-0"
6' -0
WAP
WAP
GENERAL NOTES
A. ALL OFFICES WILL GET 3 CABLES IN EACH WORK
OUTLET.
B. TELECOMMUNICATIONS AND TELEVISION FACEPLATES
SHALL MATCH ELECTRICAL SWITCH AND ELECTRICAL
PLATE FINISHES.
C. PROVIDE COVER PLATES FOR ALL UNUSED J-BOX
LOCATIONS.
D. ALL SLEEVES AND PENETRATIONS SHALL BE
ACOUSTICALLY AND FIRE STOPPED TO MEET WALL
RATING.
E. ALL COMM/DATA COPPER/FIBER INSTALLATION WILL BE
PERFORMED BY THE FAA IT GROUP.
F. ALL CONDUIT PATHWAYS FOR COMM AND SECURITY
WILL BE PART OF THE ELECTRICAL CONTRACTOR'S
RESPONSIBILITY.
G. ALL AREAS WILL RECEIVE NEW COMM DROPS TO
MATCH NEW INFRASTRUCTURE.
H. COMM/DATA OUTLETS IN ACCESS FLOOR SHALL BE
WITHIN FLOOR BOXES.
1. PROVIDE (4) - 4" EMT CONDUITS TO 1ST FLOOR COMM
ROOM 1119B.
2. RELOCATE ALL EXISTING CAT-6 CABLE TO
TELECOM ROOM 0113.
3. PROVIDE PHONE LINE TO NEW ELEVATOR
EQUIPMENT.
4. ALL ELEVATORS SHALL HAVE A SINGLE NEW CAT-6
CABLE TO NEAREST PATCH PANEL LOCATION.
CONNECT TO NEW VOICE SYSTEM.
5. (2) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
6. (4) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR..
7. (5) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
8. (4) - 4" CONDUITS UP TO COMM. ROOM 1305.
9. PROVIDE 1" CONDUIT WITH PULL STRING FROM
NEAREST COMM. ROOM TO JUNCTION BOX FOR
WIRELESS ACCESS POINT.
10.EXTEND EXISTING FIBER RUN FROM 0305 TO NEW
FACP
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
8:
:4
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
BASEMENT TELECOMMUNICATIONS PLAN -
AREA 3
RLG
WCM
JWB 543
TT103
TT103N
KEYPLAN
SCALE: 1/8" = 1'-0"
BASEMENT TELECOMMUNICATIONS PLAN - AREA 31 0 4' 8' 16'
0.7 0.8 1 2 3 4 5 6 7 8
P.2
P.1
P
N
M
L.6
L.1
L
K.6
K
J.3
J
H
G.9
M
AT
C H
LI
N
E S
EE
/T T1
MATCHLINE
SEE 1 / TT103
M
AT
C H
LI
N
E S
EE
/T T1
WORK ROOM
EXISTING STUDIO
EXISTING OFFICE
CORRIDOR
RR MEN
PRINT SHOP
EXISTING
CONFERENCE ROOM
OPEN OFFICE
CORRIDOR
EXISTING OFFICE
EXISTING WORK
AREA
EXISTING OPEN
OFFICE
EXISTING
CIRCULATION
EXISTING OFFICE
EXISTING OFFICE
EXISTING OFFICE
EXISTING OFFICE
EXISTING OFFICE
EXISTING STUDIO
EXISTING OFFICE
EXISTING OFFICE
EXISTING STORAGE
EXISTING. TEL/COM
RR MEN
12 12
WAP
GENERAL NOTES
A. ALL OFFICES WILL GET 3 CABLES IN EACH WORK
OUTLET.
B. TELECOMMUNICATIONS AND TELEVISION FACEPLATES
SHALL MATCH ELECTRICAL SWITCH AND ELECTRICAL
PLATE FINISHES.
C. PROVIDE COVER PLATES FOR ALL UNUSED J-BOX
LOCATIONS.
D. ALL SLEEVES AND PENETRATIONS SHALL BE
ACOUSTICALLY AND FIRE STOPPED TO MEET WALL
RATING.
E. ALL COMM/DATA COPPER/FIBER INSTALLATION WILL BE
PERFORMED BY THE FAA IT GROUP.
F. ALL CONDUIT PATHWAYS FOR COMM AND SECURITY
WILL BE PART OF THE ELECTRICAL CONTRACTOR'S
RESPONSIBILITY.
G. ALL AREAS WILL RECEIVE NEW COMM DROPS TO
MATCH NEW INFRASTRUCTURE.
H. COMM/DATA OUTLETS IN ACCESS FLOOR SHALL BE
WITHIN FLOOR BOXES.
1. PROVIDE (4) - 4" EMT CONDUITS TO 1ST FLOOR COMM
ROOM 1119B.
2. RELOCATE ALL EXISTING CAT-6 CABLE TO
TELECOM ROOM 0113.
3. PROVIDE PHONE LINE TO NEW ELEVATOR
EQUIPMENT.
4. ALL ELEVATORS SHALL HAVE A SINGLE NEW CAT-6
CABLE TO NEAREST PATCH PANEL LOCATION.
CONNECT TO NEW VOICE SYSTEM.
5. (2) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
6. (4) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR..
7. (5) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
8. (4) - 4" CONDUITS UP TO COMM. ROOM 1305.
9. PROVIDE 1" CONDUIT WITH PULL STRING FROM
NEAREST COMM. ROOM TO JUNCTION BOX FOR
WIRELESS ACCESS POINT.
10.EXTEND EXISTING FIBER RUN FROM 0305 TO NEW
FACP
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
8:
:5
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
BASEMENT TELECOMMUNICATIONS PLAN -
AREA 4
RLG
WCM
JWB 544
TT104
TT104N
KEYPLAN
SCALE: 1/8" = 1'-0"
BASEMENT TELECOMMUNICATIONS PLAN - AREA 41
DN
DN
DN
DN
TV
TV
TV
9 9.9 10 11 11.3 12 12.6 13 13.1 13.6 14 15 16
P.4
P.3
P.2
P.1
P
N
M
L.6
L.1
L
K.6
K
J.3
J
H
G.9
MATCHLINE
SEE 1 / TT112
M
AT
C H
LI
N
E S
EE
/T T1
ENTRYWAY
ELEV 1
STORAGE
STAIR 1
LOUNGE
CIRCULATION
CORRIDOR
WOMENS
JAN.
MENS
SYSTEMS
ELEC.
1112BREAK ROOM
OPEN OFFICE
EXISTING MECH
CONFERENCE
SMF STORAGE
CORRIDOR
CORRIDOR
A/V
VEST.
W
W
W
W
W
TT4034
TT401
EXISTING
TT401
COMM
1119E
WAP
WAP
WAP
WAP
WAP
6 3
TT403
GENERAL NOTES
A. ALL OFFICES WILL GET 3 CABLES IN EACH WORK
OUTLET.
B. TELECOMMUNICATIONS AND TELEVISION FACEPLATES
SHALL MATCH ELECTRICAL SWITCH AND ELECTRICAL
PLATE FINISHES.
C. PROVIDE COVER PLATES FOR ALL UNUSED J-BOX
LOCATIONS.
D. ALL SLEEVES AND PENETRATIONS SHALL BE
ACOUSTICALLY AND FIRE STOPPED TO MEET WALL
RATING.
E. ALL COMM/DATA COPPER/FIBER INSTALLATION WILL BE
PERFORMED BY THE FAA IT GROUP.
F. ALL CONDUIT PATHWAYS FOR COMM AND SECURITY
WILL BE PART OF THE ELECTRICAL CONTRACTOR'S
RESPONSIBILITY.
G. ALL AREAS WILL RECEIVE NEW COMM DROPS TO
MATCH NEW INFRASTRUCTURE.
H. COMM/DATA OUTLETS IN ACCESS FLOOR SHALL BE
WITHIN FLOOR BOXES.
1. PROVIDE (4) - 4" EMT CONDUITS TO 1ST FLOOR COMM
ROOM 1119B.
2. RELOCATE ALL EXISTING CAT-6 CABLE TO
TELECOM ROOM 0113.
3. PROVIDE PHONE LINE TO NEW ELEVATOR
EQUIPMENT.
4. ALL ELEVATORS SHALL HAVE A SINGLE NEW CAT-6
CABLE TO NEAREST PATCH PANEL LOCATION.
CONNECT TO NEW VOICE SYSTEM.
5. (2) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
6. (4) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR..
7. (5) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
8. (4) - 4" CONDUITS UP TO COMM. ROOM 1305.
9. PROVIDE 1" CONDUIT WITH PULL STRING FROM
NEAREST COMM. ROOM TO JUNCTION BOX FOR
WIRELESS ACCESS POINT.
10.EXTEND EXISTING FIBER RUN FROM 0305 TO NEW
FACP
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
8:
:0
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
FIRST FLOOR TELECOMMUNICATIONS PLAN
- AREA 1
RLG
WCM
JWB 545
TT111
TT111N
KEYPLAN
SCALE: 1/8" = 1'-0"
FIRST FLOOR TELECOMMUNICATIONS PLAN - AREA 11
DN
DN
DN
DN
DN
9 9.9 10 11 11.3 12 12.6 13 13.1 13.6 14 15 16
G
F
E
D
C
B
A
M
AT
C H
LI
N
E S
EE
/T T1
MATCHLINE
SEE 1 / TT111
M
AT
C H
LI
N
E S
EE
/T T1
SMF STORAGE
CORRIDOR
VEST.
EXISTING TELECOM
EXISTING SMF DATA
ROOM
ENTRY
EXISTING MECH
EXISTING ATO ROOM
SERVICE ELEV
OPEN OFFICE
WOMENS
COMM.
ELEC.
VENDING
STOR.
EXISTING STAIR
W
W
WW
TT401
EXISTING
TT4016
6 6
WAP
WAP
WAP
WAP
WAP
WAP
MENS
GENERAL NOTES
A. ALL OFFICES WILL GET 3 CABLES IN EACH WORK
OUTLET.
B. TELECOMMUNICATIONS AND TELEVISION FACEPLATES
SHALL MATCH ELECTRICAL SWITCH AND ELECTRICAL
PLATE FINISHES.
C. PROVIDE COVER PLATES FOR ALL UNUSED J-BOX
LOCATIONS.
D. ALL SLEEVES AND PENETRATIONS SHALL BE
ACOUSTICALLY AND FIRE STOPPED TO MEET WALL
RATING.
E. ALL COMM/DATA COPPER/FIBER INSTALLATION WILL BE
PERFORMED BY THE FAA IT GROUP.
F. ALL CONDUIT PATHWAYS FOR COMM AND SECURITY
WILL BE PART OF THE ELECTRICAL CONTRACTOR'S
RESPONSIBILITY.
G. ALL AREAS WILL RECEIVE NEW COMM DROPS TO
MATCH NEW INFRASTRUCTURE.
H. COMM/DATA OUTLETS IN ACCESS FLOOR SHALL BE
WITHIN FLOOR BOXES.
1. PROVIDE (4) - 4" EMT CONDUITS TO 1ST FLOOR COMM
ROOM 1119B.
2. RELOCATE ALL EXISTING CAT-6 CABLE TO
TELECOM ROOM 0113.
3. PROVIDE PHONE LINE TO NEW ELEVATOR
EQUIPMENT.
4. ALL ELEVATORS SHALL HAVE A SINGLE NEW CAT-6
CABLE TO NEAREST PATCH PANEL LOCATION.
CONNECT TO NEW VOICE SYSTEM.
5. (2) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
6. (4) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR..
7. (5) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
8. (4) - 4" CONDUITS UP TO COMM. ROOM 1305.
9. PROVIDE 1" CONDUIT WITH PULL STRING FROM
NEAREST COMM. ROOM TO JUNCTION BOX FOR
WIRELESS ACCESS POINT.
10.EXTEND EXISTING FIBER RUN FROM 0305 TO NEW
FACP
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
8:
:2
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
FIRST FLOOR TELECOMMUNICATIONS PLAN
- AREA 2
RLG
WCM
JWB 546
TT112
TT112N
KEYPLAN
SCALE: 1/8" = 1'-0"
FIRST FLOOR TELECOMMUNICATIONS PLAN - AREA 21
DN DN
0.8 1 2 3 4 5 6 7 8
G
F
E
D
C
B
A
M
AT
C H
LI
N
E S
EE
/T T1
MATCHLINE
SEE 1 / TT114
M
AT
C H
LI
N
E S
EE
/T T1
BREAK ROOM
EXISTING MECH
CORRIDOR
JAN.
ELEC.
COMM.
MENS
WOMENS
OPEN OFFICE
EXISTING DATA
ROOM CAGE
EXISTING SMF DATA
ROOM
CIRCULATION
VEST.
W
W
W
W
TT402
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
GENERAL NOTES
A. ALL OFFICES WILL GET 3 CABLES IN EACH WORK
OUTLET.
B. TELECOMMUNICATIONS AND TELEVISION FACEPLATES
SHALL MATCH ELECTRICAL SWITCH AND ELECTRICAL
PLATE FINISHES.
C. PROVIDE COVER PLATES FOR ALL UNUSED J-BOX
LOCATIONS.
D. ALL SLEEVES AND PENETRATIONS SHALL BE
ACOUSTICALLY AND FIRE STOPPED TO MEET WALL
RATING.
E. ALL COMM/DATA COPPER/FIBER INSTALLATION WILL BE
PERFORMED BY THE FAA IT GROUP.
F. ALL CONDUIT PATHWAYS FOR COMM AND SECURITY
WILL BE PART OF THE ELECTRICAL CONTRACTOR'S
RESPONSIBILITY.
G. ALL AREAS WILL RECEIVE NEW COMM DROPS TO
MATCH NEW INFRASTRUCTURE.
H. COMM/DATA OUTLETS IN ACCESS FLOOR SHALL BE
WITHIN FLOOR BOXES.
1. PROVIDE (4) - 4" EMT CONDUITS TO 1ST FLOOR COMM
ROOM 1119B.
2. RELOCATE ALL EXISTING CAT-6 CABLE TO
TELECOM ROOM 0113.
3. PROVIDE PHONE LINE TO NEW ELEVATOR
EQUIPMENT.
4. ALL ELEVATORS SHALL HAVE A SINGLE NEW CAT-6
CABLE TO NEAREST PATCH PANEL LOCATION.
CONNECT TO NEW VOICE SYSTEM.
5. (2) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
6. (4) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR..
7. (5) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
8. (4) - 4" CONDUITS UP TO COMM. ROOM 1305.
9. PROVIDE 1" CONDUIT WITH PULL STRING FROM
NEAREST COMM. ROOM TO JUNCTION BOX FOR
WIRELESS ACCESS POINT.
10.EXTEND EXISTING FIBER RUN FROM 0305 TO NEW
FACP
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
8:
:3
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
FIRST FLOOR TELECOMMUNICATIONS PLAN
- AREA 3
RLG
WCM
JWB 547
TT113
TT113N
KEYPLANSCALE: 1/8" = 1'-0"
FIRST FLOOR TELECOMMUNICATIONS PLAN - AREA 31
DN
TV
TV
0.5 0.6 0.7 0.8 1 2 3 4 5 6 7 8
P.1
P
N
M
L.6
L.1
L
K.6
K
J.3
J
H
G.9
MATCHLINE
SEE 1 / TT113
M
AT
C H
LI
N
E S
EE
/T T1
MATCHLINE
SEE 1 / TT113
M
AT
C H
LI
N
E S
EE
/T T1
COMM.
ELEC.
NURSING
MENS
1409 WOMENS
ELEV 3
1403 STORAGE
ENTRYWAY
STAIR 3
LOUNGE
CORRIDOR
EXISTING MECH
CONFERENCE
OPEN OFFICE
CIRCULATION
W
W
6 6
TT403
W
TT402
PRIVATE OFFICE
1417B
CONFERENCE ROOM
1417C
PRIVATE OFFICE
1417D
9 9
WAP
WAP
WAP
WAP
WAP
GENERAL NOTES
A. ALL OFFICES WILL GET 3 CABLES IN EACH WORK
OUTLET.
B. TELECOMMUNICATIONS AND TELEVISION FACEPLATES
SHALL MATCH ELECTRICAL SWITCH AND ELECTRICAL
PLATE FINISHES.
C. PROVIDE COVER PLATES FOR ALL UNUSED J-BOX
LOCATIONS.
D. ALL SLEEVES AND PENETRATIONS SHALL BE
ACOUSTICALLY AND FIRE STOPPED TO MEET WALL
RATING.
E. ALL COMM/DATA COPPER/FIBER INSTALLATION WILL BE
PERFORMED BY THE FAA IT GROUP.
F. ALL CONDUIT PATHWAYS FOR COMM AND SECURITY
WILL BE PART OF THE ELECTRICAL CONTRACTOR'S
RESPONSIBILITY.
G. ALL AREAS WILL RECEIVE NEW COMM DROPS TO
MATCH NEW INFRASTRUCTURE.
H. COMM/DATA OUTLETS IN ACCESS FLOOR SHALL BE
WITHIN FLOOR BOXES.
1. PROVIDE (4) - 4" EMT CONDUITS TO 1ST FLOOR COMM
ROOM 1119B.
2. RELOCATE ALL EXISTING CAT-6 CABLE TO
TELECOM ROOM 0113.
3. PROVIDE PHONE LINE TO NEW ELEVATOR
EQUIPMENT.
4. ALL ELEVATORS SHALL HAVE A SINGLE NEW CAT-6
CABLE TO NEAREST PATCH PANEL LOCATION.
CONNECT TO NEW VOICE SYSTEM.
5. (2) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
6. (4) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR..
7. (5) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
8. (4) - 4" CONDUITS UP TO COMM. ROOM 1305.
9. PROVIDE 1" CONDUIT WITH PULL STRING FROM
NEAREST COMM. ROOM TO JUNCTION BOX FOR
WIRELESS ACCESS POINT.
10.EXTEND EXISTING FIBER RUN FROM 0305 TO NEW
FACP
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
8:
:4
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
FIRST FLOOR TELECOMMUNICATIONS PLAN
- AREA 4
RLG
WCM
JWB 548
TT114
TT114N
KEYPLANSCALE: 1/8" = 1'-0"
FIRST FLOOR TELECOMMUNICATIONS PLAN - AREA 41
DN
DN
DN
TV
TV
9 9.9 10 11 11.3 12 12.6 13 13.1 13.6 14 15 16 16.1
P.4
P.3
P.2
P.1
P
N
M
L.6
L.1
L
K.6
K
J.3
J
H
G.9
M
AT
C H
LI
N
E S
EE
/T T1
OPEN OFFICE
STAIR 1
ENTRYWAY
ELEV 1
LOUNGE
CONFERENCE ROOM
LOUNGE
OUTDOOR AREA
OPEN OFFICE
STORAGE
STORAGE
SYSTEMS
ELEC.
WOMENS
MENS
COMM.
MATCHLINE
SEE 1 / TT122
W
WW
8 8
PHONE ROOM
2113A
PHONE ROOM
2113B
PHONE ROOM
2113C
PHONE ROOM
2113D
PRIVATE OFFICE
2113G
PRIVATE OFFICE
2113F
CONFERENCE ROOM
2113H
6 6 6 6
BREAK ROOM
WAP
WAP
WAP
WAP
TT401
SIM
GENERAL NOTES
A. ALL OFFICES WILL GET 3 CABLES IN EACH WORK
OUTLET.
B. TELECOMMUNICATIONS AND TELEVISION FACEPLATES
SHALL MATCH ELECTRICAL SWITCH AND ELECTRICAL
PLATE FINISHES.
C. PROVIDE COVER PLATES FOR ALL UNUSED J-BOX
LOCATIONS.
D. ALL SLEEVES AND PENETRATIONS SHALL BE
ACOUSTICALLY AND FIRE STOPPED TO MEET WALL
RATING.
E. ALL COMM/DATA COPPER/FIBER INSTALLATION WILL BE
PERFORMED BY THE FAA IT GROUP.
F. ALL CONDUIT PATHWAYS FOR COMM AND SECURITY
WILL BE PART OF THE ELECTRICAL CONTRACTOR'S
RESPONSIBILITY.
G. ALL AREAS WILL RECEIVE NEW COMM DROPS TO
MATCH NEW INFRASTRUCTURE.
H. COMM/DATA OUTLETS IN ACCESS FLOOR SHALL BE
WITHIN FLOOR BOXES.
1. PROVIDE (4) - 4" EMT CONDUITS TO 1ST FLOOR COMM
ROOM 1119B.
2. RELOCATE ALL EXISTING CAT-6 CABLE TO
TELECOM ROOM 0113.
3. PROVIDE PHONE LINE TO NEW ELEVATOR
EQUIPMENT.
4. ALL ELEVATORS SHALL HAVE A SINGLE NEW CAT-6
CABLE TO NEAREST PATCH PANEL LOCATION.
CONNECT TO NEW VOICE SYSTEM.
5. (2) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
6. (4) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR..
7. (5) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
8. (4) - 4" CONDUITS UP TO COMM. ROOM 1305.
9. PROVIDE 1" CONDUIT WITH PULL STRING FROM
NEAREST COMM. ROOM TO JUNCTION BOX FOR
WIRELESS ACCESS POINT.
10.EXTEND EXISTING FIBER RUN FROM 0305 TO NEW
FACP
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
8:
:5
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
SECOND FLOOR TELECOMMUNICATIONS
PLAN - AREA 1
RLG
WCM
JWB 549
TT121
TT121N
KEYPLAN
SCALE: 1/8" = 1'-0"
SECOND FLOOR TELECOMMUNICATIONS PLAN - AREA 13 0 4' 8' 16'
DN
DN
DN
9 9.9 10 11 11.3 12 12.6 13 13.1 13.6 14 15 16 16.1
G
F
E
D
C
B
A
M
AT
C H
LI
N
E S
EE
/T T1
OUTDOOR AREA
OPEN OFFICE
EXISTING STAIR
OPEN OFFICE
STORAGE
SERVICE ELEV
MENS
WOMENS
COMM.
ELEC.
JAN.
OPEN OFFICE
MATCHLINE
SEE 3 / TT121
W
W
TT401
CONFERENCE ROOM
2113H
PRIVATE OFFICE
2304D
PRIVATE OFFICE
2304E
PHONE ROOM
2304G
PHONE ROOM
2304F
6 6
WAP
WAP
WAP
GENERAL NOTES
A. ALL OFFICES WILL GET 3 CABLES IN EACH WORK
OUTLET.
B. TELECOMMUNICATIONS AND TELEVISION FACEPLATES
SHALL MATCH ELECTRICAL SWITCH AND ELECTRICAL
PLATE FINISHES.
C. PROVIDE COVER PLATES FOR ALL UNUSED J-BOX
LOCATIONS.
D. ALL SLEEVES AND PENETRATIONS SHALL BE
ACOUSTICALLY AND FIRE STOPPED TO MEET WALL
RATING.
E. ALL COMM/DATA COPPER/FIBER INSTALLATION WILL BE
PERFORMED BY THE FAA IT GROUP.
F. ALL CONDUIT PATHWAYS FOR COMM AND SECURITY
WILL BE PART OF THE ELECTRICAL CONTRACTOR'S
RESPONSIBILITY.
G. ALL AREAS WILL RECEIVE NEW COMM DROPS TO
MATCH NEW INFRASTRUCTURE.
H. COMM/DATA OUTLETS IN ACCESS FLOOR SHALL BE
WITHIN FLOOR BOXES.
1. PROVIDE (4) - 4" EMT CONDUITS TO 1ST FLOOR COMM
ROOM 1119B.
2. RELOCATE ALL EXISTING CAT-6 CABLE TO
TELECOM ROOM 0113.
3. PROVIDE PHONE LINE TO NEW ELEVATOR
EQUIPMENT.
4. ALL ELEVATORS SHALL HAVE A SINGLE NEW CAT-6
CABLE TO NEAREST PATCH PANEL LOCATION.
CONNECT TO NEW VOICE SYSTEM.
5. (2) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
6. (4) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR..
7. (5) - 4" CONDUITS. COORDINATE LOCATION WITH ALL
DISCIPLINES. REFER DETAIL 10/TT501FOR CABLE
TRANSITION TO RAISED FLOOR.
8. (4) - 4" CONDUITS UP TO COMM. ROOM 1305.
9. PROVIDE 1" CONDUIT WITH PULL STRING FROM
NEAREST COMM. ROOM TO JUNCTION BOX FOR
WIRELESS ACCESS POINT.
10.EXTEND EXISTING FIBER RUN FROM 0305 TO NEW
FACP
SHEET KEYNOTES
(ALL NOTES MAY NOT BE USED)
DESIGNED BY:
DRAWN BY:
WORK ORDER NO.
OFFICE OF
ISSUED BY
DRAWING NO.
DATE
PREPARED BYREVIEWED BY
REV DATE
APPROVED BY
DESCRIPTION
OF
SHEET NO.
APP'DCHECK
FACILITY MANAGEMENT
AMP-400
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
FEDERAL AVIATION ADMINISTRATION
DECEMBER 20, 2017
405/840-2931 www.fsb-ae.com
13-007860 AMP-400-E-
FRANKFURT SHORT BRUZA
DEPARTMENT OF TRANSPORTATION
5801 BROADWAY EXT., SUITE 500
OKLAHOMA CITY, OKLAHOMA
Work Request Construction No: 13-007860
MPB-24 (MULTI-PURPOSE BUILDING)
RENOVATION
M.OWENSBY
JASON K.
BLUBAUGH
25269
O K L A H O M A
LI
C
EN
S E
D
PRO FES S IONA L
ENG
I NEER
1/ 3/
8:
:1
AM
C
:\U se rs \jk b\ Do cu m en ts
\M y
Re vi t\6
_S ec ur
_j kb
.rv t
SECOND FLOOR TELECOMMUNICATIONS
PLAN - AREA 2
RLG
WCM
JWB 550
TT122
TT122N
KEYPLANSCALE: 1/8" = 1'-0"
SECOND FLOOR TELECOMMUNICATIONS PLAN - AREA 21
0.8 1 2 3 4 5 6 7 8
G
F
E
D
C
B
A
OPEN OFFICE
2308 STORAGE
LOBBY
NURSING
SYSTEMS
ELEC.
COMM.
MENS
WOMENS
OPEN OFFICE
OUTDOOR AREA
OPEN OFFICE
M
AT
C H
LI
N
E S
EE
/T T1
M
AT
C
H
LI
N E
S
EE
/T
T1
MATCHLINE
SEE 1 / TT124
W
TT401
CONFERENCE ROOM
2304C
PRIVATE OFFICE
2304A
PRIVATE OFFICE
2304B
6 6 W
WAP
WAP
WAP
6WAP
GENERAL NOTES
A. ALL OFFICES WILL GET 3 CABLES IN EACH WORK
OUTLET.
B. TELECOMMUNICATIONS AND TELEVISION FACEPLATES
SHALL MATCH ELECTRICAL SWITCH AND ELECTRICAL
PLATE FINISHES.
C. PROVIDE COVER PLATES FOR ALL UNUSED J-BOX
LOCATIONS.
D. ALL SLEEVES AND PENETRATIONS SHALL BE
ACOUSTICALLY AND FIRE STOPPED TO MEET WALL
RATING.
E. ALL COMM/DATA COPPER/FIBER INSTALLATION WILL BE
PERFORMED BY THE FAA IT GROUP.
F. ALL CONDUIT PATHWAYS FOR COMM AND SECURITY
WILL BE PART OF THE ELECTRICAL CONTRACTOR'S
RESPONSIBILITY.
G. ALL AREAS WILL RECEIVE NEW COMM DROPS TO
MATCH NEW INFRASTRUCTURE.
H. COMM/DATA OUTLETS IN…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.