ATTACHMENT 2-DRAWINGS VOLUME 2 PLUMBING.pdf

PDF 7 MB Posted

Attached to
CONSTRUCTION: Multi-Purpose Building Renovation, FAA, MMAC, Oklahoma City, OK
Solicitation number
6973GH-18-R-00009
Issued by

About this file

ATTACHMENT 2-DRAWINGS VOLUME 2 PLUMBING (pdf)

View the file

Other files

File Type Posted
ATTACHMENT 13-ASBESTOS REPORTS.pdf PDF
ATTACHMENT 10- .html file.htm HTM file
ATTACHMENT 5-SF25.pdf PDF
ATTACHMENT 2-DRAWINGS VOLUME 1 ARCHITECTURAL.pdf PDF
ATTACHMENT 10R-BUSINESS RELATIONSHIP AFFIDAVIT.pdf PDF
ATTACHMENT 7-CONTRACTOR'S RELEASE.pdf PDF
ATTACHMENT 4-WAGE DETERMINATION OK49.pdf PDF
ATTACHMENT 15-ADDENDUM 2.pdf PDF
ATTACHMENT 2-DRAWINGS VOLUME 2 MECHANICAL.pdf PDF
ATTACHMENT 3-CHAPTER 33 CONSTRUCTION SAFETY.pdf PDF
ATTACHMENT 2-DRAWINGS VOLUME 1 CIVIL.pdf PDF
ATTACHMENT 8-OPERATIONAL CONTROL DOCUMENTS.pdf PDF
20180116 SITE VISIT ATTENDEES SIGN IN SHEET.pdf PDF
ATTACHMENT 2-DRAWINGS VOLUME 3 TELECOM AND SECURITY.pdf PDF
AMENDMENT 0001.pdf PDF
AMENDMENT 0003.pdf PDF
ATTACHMENT 5R-SF25 PERFORMANCE BOND 8/2016.pdf PDF
ATTACHMENT 12-CLIENT AUTHORIZATION LETTER.docx DOCX document
ATTACHMENT 2-DRAWINGS VOLUME 2 INTERIORS AND FIRE PROTECTION.pdf PDF
24-ATTEND Sign In Second Site Visit.pdf PDF
ATTACHMENT 6R-SF25A PAYMENT BOND 8/2016.pdf PDF
SIR 6973GH-18-R-00009.pdf PDF
ATTACHMENT 6-SF25A.pdf PDF
AMENDMENT 0002.pdf PDF
ATTACHMENT 1-SPECIFICATIONS VOLUME 2.pdf PDF
ATTACHMENT 9- .html file.htm HTM file
ATTACHMENT 9R-ANTI/NON-COLLUSION AFFIDAVIT.pdf PDF
ATTACHMENT 11-PAST PERFORMANCE SURVEY.pdf PDF
ATTACHMENT 9-OCAT 00310 ANTI/NON-COLLUSION AFFIDAVIT.pdf PDF
ATTACHMENT 1-SPECIFICATIONS VOLUME 1.pdf PDF
ATTACHMENT 2-DRAWINGS VOLUME 1 STRUCTURAL.pdf PDF
ATTACHMENT 2-DRAWINGS VOLUME 3 ELECTRICAL.pdf PDF
ATTACHMENT 14-ADDENDUM 1.pdf PDF
ATTACHMENT 10-OCAT 00320 BUSINESS RELATIONSHIP AFFIDAVIT.pdf PDF
ATTACHMENT 13-ASBESTOS REPORTS.pdf PDF
ATTACHMENT 6-SF25A.pdf PDF
ATTACHMENT 9-OCAT 00310 ANTI/NON-COLLUSION AFFIDAVIT.pdf PDF
SIR 6973GH-18-R-00009.pdf PDF
ATTACHMENT 14-ADDENDUM 1.pdf PDF
ATTACHMENT 1-SPECIFICATIONS VOLUME 2.pdf PDF
ATTACHMENT 10-OCAT 00320 BUSINESS RELATIONSHIP AFFIDAVIT.pdf PDF
ATTACHMENT 2-DRAWINGS VOLUME 3 TELECOM AND SECURITY.pdf PDF
AMENDMENT 0001.pdf PDF
ATTACHMENT 2-DRAWINGS VOLUME 1 ARCHITECTURAL.pdf PDF
20180116 SITE VISIT ATTENDEES SIGN IN SHEET.pdf PDF
ATTACHMENT 2-DRAWINGS VOLUME 2 PLUMBING.pdf PDF
ATTACHMENT 5R-SF25 PERFORMANCE BOND 8/2016.pdf PDF
ATTACHMENT 2-DRAWINGS VOLUME 1 STRUCTURAL.pdf PDF
AMENDMENT 0003.pdf PDF
ATTACHMENT 2-DRAWINGS VOLUME 2 INTERIORS AND FIRE PROTECTION.pdf PDF
Show 40 more

Latest 50 of 251 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PREVENTER

*RPBP...REDUCED PRESSURE BACKFLOW

NATURAL GAS, MEDIUM PRESSURE (50 PSIG)MG

NO..............................................NUMBER

NON-POTABLE WATER (MAKE-UP)NPW

URINAL

SERVICE SINK/BASIN

WATER CLOSET

LAVATORY

DESCRIPTION

ASME RELIEF VALVE

PRESSURE AND

REDUCER, CONCENTRIC

REDUCER, ECCENTRIC

TEMPERATURE RELIEF

SYMBOL

SINK

FLOOR DRAIN

DRINKING FOUNTAIN

SHOWER HEAD

CLEANOUT, WALL

STRAINER, "Y" TYPE

DOUBLE CHECK VALVE BACKFLOW

PREVENTION DEVICE

WATER HAMMER ARRESTOR

HOSE BIBB

PIPE ANCHOR

PIPE SLEEVE THRU

CO

HB

PIPE SLOPE IN

THERMOMETER

FLOW IN DIRECTION OF ARROW

DIRECTION OF ARROW

UNION

THERMOMETER WELL

LUBRICATED PLUG VALVE

COCK (C=COMPOUND GAUGE)

PRESSURE GAUGE WITH GAUGE

1T

TW

C

PI

WALL, FOOTING ETC

CO CLEANOUT, FLOOR

DESCRIPTIONSYMBOL

V

SS

DOMESTIC COLD WATER

DOMESTIC HOT WATER RETURN

DOMESTIC HOT WATER

SOIL OR WASTE - ABOVE FLOOR

D

G

DRAIN

NATURAL GAS, LOW PRESSURE (0.5 PSI)

FP

CD

FIRE PROTECTION MAIN

CONDENSATE DRAIN

SOIL OR WASTE VENT

CAP

BLIND FLANGE

RELIEF VALVE

COMPRESSED AIR

PIPE ROUTED TO FLOOR DRAIN

RISER DOWN (ELBOW)

RISER UP (ELBOW)

TEE DOWN

RISE OR DROP

BOTTOM CONNECTION

GATE VALVE OR ISOLATION VALVE

FOR GPM SHOWN IN ().

SIDE CONNECTION

ANGLE VALVE

TOP CONNECTION

TEE UP

CHECK VALVE (STRAIGHT)

BALL VALVE

GLOBE VALVE

PRESSURE REDUCING VALVE

U

V

VOL............................................VOLUME

*V....................................................VENT

W

X

Y

XFMR...............................TRANSFORMER

VTR............................VENT THRU ROOF

W....................................................WATT

W/...................................................WITH

W/O..........................................WITHOUT

R

M

*MA......................................MEDICAL AIR

MAINT................................MAINTENANCE

MATL.......................................MATERIAL

S

N

O

MAX..........................................MAXIMUM

MBH.............THOUSAND BTU PER HOUR

N..................................................NORTH

NA...............................NOT APPLICABLE

*NCS.............NATIONAL CAD STANDARDS

NEG..........................................NEGATIVE

NIC............................NOT IN CONTRACT

NOM...........................................NOMINAL

OC........................................ON CENTER

*s.................................................SECOND

S..................................................SOUTH

SCHED....................................SCHEDULE

REF.......................................REFERENCE

REQD.......................................REQUIRED

REV.............................REVISE, REVISION

RFI.............REQUEST FOR INFORMATION

RPM..............REVOLUTIONS PER MINUTE

RD.......................................ROOF DRAIN

T

P

Q

OD............................OUTSIDE DIAMETER

PCT..........................................PERCENT

PH................................................PHASE

PKG..........................................PACKAGE

PLBG.......................................PLUMBING

QA.........................QUALITY ASSURANCE

T&P.......TEMPERATURE AND PRESSURE

TECH.....................................TECHINICAL

TFA.............................TO FLOOR ABOVE

SF........................SQUARE FEET (FOOT)

SPEC................................SPECIFICATION

SCHEM..................................SCHEMATIC

SECT..........................................SECTION

G

H

D

DIA...........................................DIAMETER

DF...........................DRINKING FOUNTAIN

DEMO....................................DEMOLITION

D...................................................DRAIN

I

E

ELEC.........................................ELECTRIC

ETC............ET CETRA (AND SO FORTH)

EST..........................................ESTIMATE

EQUIV...................................EQUIVALENT

EQUIP....................................EQUIPMENT

EMER....................................EMERGENCY

*ELL...............................................ELBOW

EL...........................................ELEVATION

EA..................................................EACH

DIAG..................DIAGRAM, DIAGRAMATIC

A

B

C

B/B...............................BACK TO BACK

BFF...................BELOW FINISHED FLOOR

AFF..................ABOVE FINISHED FLOOR

*ABV.................................................ABOVE

J

K

L F

FCO............................FLOOR CLEANOUT

CL......................................CENTER LINE

CAP.........................................CAPACITY

*CFH....................CUBIC FEET PER HOUR

CI...........................................CAST IRON

L.....................................................LITER

*HR..................................................HOUR

HSKPG............................HOUSEKEEPING

HW.......................................HOT WATER

HWR.......................HOT WATER RETURN

ID.................................INSIDE DIAMETER

*IN.................................................INCHES

IN WC...............INCHES WATER COLUMN

G......................................NATURAL GAS

GA.....................................GAGE, GAUGE

GAL.............................................GALLON

GALV....................................GALVANIZED

GPH..........................GALLON PER HOUR

GPM.......................GALLON PER MINUTE

HB.........................................HOSE BIBB

HORIZ..................................HORIZONTAL

HP.....................................HORSEPOWER

ALT.......................................ALTERNATE

ARCH...........ARCHITECT,ARCHITECTURAL

APPROX............................APPROXIMATE

AUTO.....................................AUTOMATIC

AUX........................................AUXILIARY

AVG..........................................AVERAGE

AGA..........AMERICAN GAS ASSOCIATION

BLDG.........................................BUILDING

BFP....................BACKFLOW PREVENTER

BTU....................BRITISH THERMAL UNIT

BTUH......................................BTU/HOUR

COL............................................COLUMN

CO........................................CLEAN OUT

CLG.............................................CEILING

CW......................................COLD WATER

CORR.......................................CORRIDOR

*CP.................................CHROME PLATED

CTR.............................................CENTER

CORD.....................................CORDINATE

CONN.....................................CONNNECT

*CA...............................COMPRESSED AIR

CONC......................................CONCRETE

CONT..................CONTINUE, CONTINOUS

DWV......................DRAIN, WASTE, VENT

DN..................................................DOWN

DWH..............DOMESTIC WATER HEATER

DEG.............................................DEGREE

DWG..........................................DRAWING

EWC................ELECTRIC WATER COOLER

EXIST.........................................EXISTING

EXT..........................................EXTERIOR

F..........................................FAHRENHEIT

FD......................................FLOOR DRAIN

FDC......FIRE DEPARTMENT CONNECTION

*FF..................................FINISHED FLOOR

FFA........................FROM FLOOR ABOVE

FP...............................FIRE PROTECTION

FM..............................FACTORY MUTUAL

FLR...............................................FLOOR

FLEX..........................................FLEXIBLE

FFB........................FROM FLOOR BELOW

FLA.............................FULL LOAD AMPS

FV.....................................FLUSH VALVE

FURN.....................................FURNISHED

FTG............................................FOOTING

FT.........................................FOOT, FEET

FPM............................FEET PER MINUTE

FPS...........................FEET PER SECOND

FH....................................FIRE HYDRANT

FIG...............................................FIGURE

FIXT............................................FIXTURE

GC......................GENERAL CONTRACTOR

HP.....................................HORSEPOWER

HYD.......................................HYDRAULIC

HYD.........................................HYDRANT

HOSP.......................................HOSPITAL

HT...............................................HEIGHT

Hz.................................................HERTZ

INV EL.......................INVERT ELEVATION

INSUL....................................INSULATION

INFO...................................INFORMATION

JAN CLO...................JANITOR'S CLOSET

*IPC......INTERNATIONAL PLUMBING CODE

IPS.................................IRON PIPE SIZE

ISO.........................................ISOMETRIC

KWH..............................KILOWATT HOUR

KW...........................................KILOWATT

K............................................THOUSAND

LBS............................................POUNDS

LF..........................LINEAR FEET (FOOT)

LKR.............................................LOCKER

LAV.........................................LAVATORY

MFR...............................MANUFACTURER

MFG..............................MANUFACTURING

MEZZ.....................................MEZZANINE

MECH...................................MECHANICAL

MED.............................................MEDIUM

MC................MECHANICAL CONTRACTOR

MTD..........................................MOUNTED

MOD............................................MODIFY

MISC..............................MISCELLANEOUS

MIN............................................MINIMUM

MULT........................................MULTIPLE

*MG....MEDIUM PRESSURE NATURAL GAS

NTS.................................NOT TO SCALE

OPT.........................................OPTIONAL

OPP.........................................OPPOSITE

OZ................................................OUNCE

OUT............................................OUTLET

ORIG.........................................ORIGINAL

PSI.............POUNDS PER SQUARE INCH

PRV...........PRESSURE REDUCING VALVE

PRESS....................................PRESSURE

PRELIM...............................PRELIMINARY

PPM........................PARTS PER MILLION

PSIA....POUNDS PER SQ. IN. ABSOLUTE

PSIG............POUNDS PER SQ. IN. GAGE

PVC.......................POLYVINYL CHLORIDE

PWR.............................................POWER

QTY..........................................QUANTITY

RFP................REQUEST FOR PROPOSAL

RM.................................................ROOM

RPS.............REVOLUTIONS PER SECOND

SQ..............................................SQUARE

STOR........................................STORAGE

STRUCT...............................STRUCTURAL

SYS.............................................SYSTEM

TYP............................................TYPICAL

TSTAT.................................THERMOSTAT

THRU........................................THROUGH

TFB.............................TO FLOOR BELOW

TEMP................................TEMPERATURE

Ø................................ROUND

Ø................................PHASE

Ø..........................DIAMETER

°...............................DEGREE

...................................ANGLE

%............................PERCENT

UNO.............UNLESS NOTED OTHERWISE

UL..........UNDERWRITERS LABORATORIES

WT...............................................WEIGHT

WHA............WATER HAMMER ARRESTOR

WG......................................WATER GAGE

W....................................................WEST

WC.................................WATER COLUMN

WH...............................WATER HYDRANT

WH..................................WATER HEATER

YR..................................................YEAR

YH.................................YARD HYDRANT

WC..................................WATER CLOSET

V....................................................VOLT

TEXT SYMBOLS

CHECK VALVE (SWING GATE)

REDUCED PRESSURE BACKFLOW

PREVENTER W/STRAINER

*CBV..............CIRCUIT BALANCING VALVE

CIRCUIT BALANCING VALVE - SET(1.2)

WALL HYDRANTWH

(APPLIES TO ALL SHEETS)

A. SLOPE SOIL AND WASTE PIPE 4" AND LARGER AT

1/8" PER FT. MINIMUM, SIZE LESS THAN 4" SLOPE

1/4" PER FT. MINIMUM, UNLESS NOTED

OTHERWISE.

B. ALL PIPING SHALL BE COORDINATED WITH CIVIL

UTILITY PIPING, FIRE PROTECTION, DUCTWORK,

MECHANICAL PIPING, LIGHTING, STRUCTURAL AND

ARCHITECTURAL SYSTEMS.

C. PIPE CLEANOUTS SHALL BE LINE SIZE (6" MAX.).

LOCATE 100' APART MAXIMUM FOR SIZES UP

THROUGH 6".

D. PLUMBING VENTS THROUGH ROOF (VTR) SHALL

BE 3" MINIMUM. SMALLER VTR'S INDICATED SHALL

INCREASE TO 3" PIPE, 12" BELOW ROOF. INSTALL

VENT THRU ROOF (VTR) PENETRATIONS PER

ARCHITECTURAL.

E. ACCESS PANELS SHALL BE PROVIDED FOR ALL

WATER HAMMER ARRESTORS LOCATED IN WALLS

TO ACCESS EQUIPMENT. PANEL SHALL BE AS

LARGE AS PRACTICAL FOR THE FUNCTION THEY

ARE INTENDED.

F. PROVIDE TRAP PRIMERS FOR ALL TRAPS

REPLACED ON FLOOR DRAINS. PROVIDE ACCESS

PANEL TO SERVICE TRAP PRIMER.

G. MATERIALS WITHIN RETURN AIR PLENUM SHALL

MEET ALL REQUIREMENTS OF APPLICABLE

CODES. INCLUDING IBC.

H. ALL EXISTING SANITARY WASTE, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING ABOVE

BASEMENT FLOOR TO BE DEMOLISHED UNLESS

NOTED OTHERWISE.

I. DEMOLITION OF ANY EXISTING CONSTRUCTION

REQUIRED BY PLUMBING CONTRACTOR TO

PROPERLY COMPLETE THEIR WORK SHALL BE

ACCOMPLISHED AS A PART OF THEIR WORK AND

SHALL BE PART OF THE PRIME CONTRACT.

J. ALL RISERS, STACKS, LEADERS, RUNOUTS OR

BRANCHES THROUGH FLOOR LEVELS SHALL BE

SLEEVED AND FIRE CAULKED. SLEEVES SHALL

EXTEND MINIMUM OF 2" ABOVE FLOOR LEVEL.

K. ALL EXISTING SANITARY DRAIN PIPING THAT

REMAINS TO BE ROOTED OUT AFTER

CONSTRUCTION TO REMOVE RUST AND

BLOCKAGES.

L. REMOVE EXISTING CLEAN-OUTS, FLOOR DRAINS,

FIXTURE CONNECTIONS LOCATED ON

ABANDONED PIPING AND COVER OVER WITH

OTHER SURFACES.

M. LOCATE CLEAN-OUTS IN WALLS INSTEAD OF

FLOORS WHERE POSSIBLE.

N. GENERAL CONTRACTOR RESPONSIBLE FOR

FLOOR SLAB SAWCUT, BACKFILL AND PATCH

WHERE APPLICABLE.

A COMPRESSED AIR - ABOVE FLOOR

A

COMPRESSED AIR

OUTLET STATION

ABBREVIATIONS GENERAL NOTES

IE................................INVERT ELEVATION

COMB.................................COMBINATION

NPW.....................NONPOTABLE WATER

SS SOIL OR WASTE - BELOW

FLOOR OR GRADE

A COMPRESSED AIR - BELOW

FLOOR OR GRADE

DSN.....................DOWNSPOUT NOZZLE

ORD.............OVERFLOW ROOF DRAIN

OSD.............OVERFLOW STORM DRAIN

PCO..............................PIPE CLEANOUT

WCO..............................WALL CLEANOUT

WF....................................WATER FILTER

RH...................................ROOF HYDRANT

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

8:

:2

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

LEGEND & ABBREVIATIONS

RDR

BAS

RDR 297

P-001

P-001

M

AT

C H

LI

N

E S

EE

1/

P D

MATCH LINE

SEE 1/PD102

H H

J J

K K

L L

M M

N N

P P

P.1 P.1

EXISTING UNDERFLOOR

SANITARY SEWER. TYP.

EXISTING STORM

DRAIN PIPING UP

HIGH (TYP)

3 3

8 8

EXISTING SSD

PERIMETER

DRAIN (TYP)

EXISTING SUB-SURFACE

DRAINAGE (TYP)

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

8:

:4

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

BASEMENT FLOOR PLUMBING DEMOLITION

PLAN - AREA 1

RDR

BAS

RDR 298

PD101

PD101

KEYPLAN

SCALE: 1/8" = 1'-0"

1 BASEMENT FLOOR PLUMBING DEMOLITION PLAN - AREA 1 0 4' 8' 16'

N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN PIPING TO BE DEMOLISHED.

3. EXISTING SANITARY SEWER PIPING TO BE ABANDON

BELOW GRADE. FLOOR CLEANOUTS, FLOOR DRAINS,

FIXTURES AND PIPING PENETRATIONS TO BE CAPPED

AND COVER WITH FLOOR SURFACE.

4. EXISTING SUB-SURFACE DRAINAGE TO REMAIN.

5. EXISTING SUB-SURFACE PERIMETER DRAINAGE TO

REMAIN.

6. EXISTING SUB-SURFACE DRAINAGE TO BE

ABANDONED.

7. EXISTING SUB-SURFACE PERIMETER DRAINAGE TO BE

DEMOLISHED.

8. DEMOLISH SUB-SURFACE PERIMETER DRAINAGE

BEYOND THIS POINT FOR NEW FOUNDATION. REFER

TO P-101 FOR NEW WORK..

9. DEMOLISH SUB-SURFACE DRAINAGE BEYOND THIS

POINT FOR NEW FOUNDATION. REFER TO P-101 FOR

NEW WORK..

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY WASTE, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING ABOVE BASEMENT

FLOOR TO BE DEMOLISHED AND ALL PLUMBING TO BE

NEW UNLESS NOTED OTHERWISE.

C. ALL EXISTING UNDERFLOOR SANITARY SEWER PIPING

BELOW BASEMENT IS BE ABANDONED IN PLACE

UNLESS NOTED OTHERWISE.

D. FIELD VERIFY LOCATION AND SIZE OF EXISTING

CONNECTIONS TO SANITARY SEWER AND DOMESTIC

WATER ON SITE PRIOR TO CONSTRUCTION.

E. REFER TO PLANS P-101 THRU P-134 FOR NEW WORK.

UP

DN

MATCH LINE

SEE 1/PD101

M

AT

C H

LI

N

E S

EE

1/

P D

A A

B B

C C

D D

E E

F F

G G

16.1

16.1

EXISTING UNDERFLOOR

SANITARY SEWER, TYP.

EXISTING STORM

DRAIN PIPING UP

HIGH (TYP)

EXISTING DOCK

DRAIN PIPING TO

REMAIN (TYP)

EXISTING

SUB-SURFACE

DRAINAGE (TYP)

EXISTING SSD

PERIMETER

DRAINS (TYP)

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

8:

:4

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

BASEMENT FLOOR PLUMBING DEMOLITION

PLAN - AREA 2

RDR

BAS

RDR 299

PD102

PD102

KEYPLAN

SCALE: 1/8" = 1'-0"

1 BASEMENT FLOOR PLUMBING DEMOLITION PLAN - AREA 2

0 4' 8' 16' N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING DUPLEX SUMP PUMPS TO BE DEMOLISHED.

BASIN TO REMAIN.

3. EXISTING STORM DRAIN PIPING TO BE DEMOLISHED.

4. EXISTING SANITARY SEWER PIPING TO BE ABANDON

BELOW GRADE. FLOOR CLEANOUTS, FLOOR DRAINS,

FIXTURES AND PIPING PENETRATIONS TO BE CAPPED

AND COVERED WITH FLOOR SURFACE.

5. EXISTING SUB-SURFACE DRAINAGE TO REMAIN.

6. EXISTING SUB-SURFACE PERIMETER DRAINS TO

REMAIN.

7. DEMOLISH SUB-SURFACE DRAIN PIPE BEYOND THIS

POINT FOR NEW FOUNDATION. REFER TO P-102 FOR

NEW WORK.

8. EXISTING STORM DRAINAGE PIPE AT LOADING DOCK

TO REMAIN.

9. EXISTING STORM DRAINAGE DISCHARGE PIPE FROM

SUMP PUMPS TO REMAIN.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY WASTE, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING ABOVE BASEMENT

FLOOR TO BE DEMOLISHED AND ALL PLUMBING TO BE

NEW UNLESS NOTED OTHERWISE.

C. ALL EXISTING UNDERFLOOR SANITARY SEWER PIPING

BELOW BASEMENT IS BE ABANDONED IN PLACE

UNLESS NOTED OTHERWISE.

D. FIELD VERIFY LOCATION AND SIZE OF EXISTING

CONNECTIONS TO SANITARY SEWER AND DOMESTIC

MATCH LINE

SEE 1/PD104

M

AT

C H

LI

N

E S

EE

1/

P D

A A

B B

C C

D D

E E

F F

G G

EXISTING

UNDERFLOOR

SANITARY

SEWER. TYP.

EXISTING WATER

HEATER TO BE

REMOVED.

1 1

EXISTING

STORM DRAIN

PIPING UP

HIGH (TYP)

EXISTING BOILER &

CHILLER DRAIN

PIPING & FLOOR

DRAINS THIS

AREA TO REMAIN

25 5

5 5

EXISTING SUB-

SURFACE DRAINAGE

(TYP)

EXISTING SUB-SURFACE

PERIMETER DRAINAGE

(TYP)

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

8:

:5

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

BASEMENT FLOOR PLUMBING DEMOLITION

PLAN - AREA 3

RDR

BAS

RDR 300

PD103

PD103

KEYPLAN

SCALE: 1/8" = 1'-0"

1 BASEMENT FLOOR PLUMBING DEMOLITION PLAN - AREA 3

0 4' 8' 16' N

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING DUPLEX SUMP PUMPS TO BE DEMOLISHED.

EXISTING SUMP BASIN TO REMAIN.

3. EXISTING STORM DRAIN PIPING TO BE DEMOLISHED.

4. EXISTING DRAIN PIPING TO BE ABANDONED BEYOND

THIS POINT FOR NEW FOUNDATION. REFER TO P-103

FOR NEW WORK.

5. EXISTING SUB-SURFACE DRAINS TO REMAIN.

6. EXISTING SANITARY SEWER PIPING TO BE ABANDON

BELOW GRADE. FLOOR CLEANOUTS, FLOOR DRAINS,

FIXTURES AND PIPING PENETRATIONS TO BE CAPPED

AND COVERED WITH FLOOR SURFACE.

7. EXISTING DRAIN PIPING TO BE ABANDON AND FLOOR

CLEANOUTS TO BE CAPPED.

8. EXISTING SUB-SURFACE PERIMETER DRAIN TO

REMAIN.

9. DEMOLISH SUB-SURFACE DRAIN BEYOND THIS POINT

FOR NEW FOUNDATION. REFER TO P-103 FOR NEW

WORK.

10.EXISTING SUB-SURFACE PERIMETER PIPE UP TO

CLEANOUT AT GRADE TO REMAIN.

GENERAL NOTES

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY WASTE, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING ABOVE BASEMENT

FLOOR TO BE DEMOLISHED AND ALL PLUMBING TO BE

NEW UNLESS NOTED OTHERWISE.

C. ALL EXISTING UNDERFLOOR SANITARY SEWER PIPING

BELOW BASEMENT IS BE ABANDONED IN PLACE

UNLESS NOTED OTHERWISE.

D. FIELD VERIFY LOCATION AND SIZE OF EXISTING

CONNECTIONS TO SANITARY SEWER AND DOMESTIC

C H

LI

N

E S

EE

1/

P D

MATCH LINE

SEE 1/PD103

H H

J J

K K

L L

M M

N N

P P

0.9

0.9

EXISTING UNDERFLOOR

SANITARY SEWER. TYP.

EXISTING STORM

DRAIN PIPING UP

HIGH (TYP)

SS

SS

2"

2"

2"

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

8:

:0

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

BASEMENT FLOOR PLUMBING DEMOLITION

PLAN - AREA 4

RDR

BAS

RDR 301

PD104

PD104

KEYPLAN

SCALE: 1/8" = 1'-0"

1 BASEMENT FLOOR PLUMBING DEMOLITION PLAN - AREA 4

0 4' 8' 16' N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN PIPING TO BE DEMOLISHED.

3. EXISTING SUB-SURFACE DRAIN PIPING TO REMAIN.

4. EXISTING SANITARY SEWER PIPING TO BE ABANDON

BELOW GRADE. FLOOR CLEANOUTS, FLOOR DRAINS,

FIXTURES AND PIPE PENETRATIONS TO BE CAPPED

COVER WITH FLOOR SURFACE.

5. EXISTING SANITARY SEWER PIPING TO REMAIN.

6. EXISTING SUB-SURFACE PIPING TO BE DEMOLISHED

BETWEEN THESE POINTS FOR NEW FOUNDATION.

REFER TO P-104 FOR NEW WORK.

7. EXISTING SANITARY SEWER TO BE DEMOLISHED AT

THIS POINT. REFER TO P-104 FOR NEW WORK.

8. EXISTING SUB-SURFACE PERIMETER DRAINAGE TO

REMAIN.

9. EXISTING SUB-SURFACE PERIMETER DRAINAGE TO BE

DEMOLISHED.

10.DEMOLISH EXISTING SUB-SURFACE PERIMETER

DRAIN BEYOND THIS POINT FOR NEW FOUNDATION.

REFER TO P-104 FOR NEW WORK.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY WASTE, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING ABOVE BASEMENT

FLOOR TO BE DEMOLISHED AND ALL PLUMBING TO BE

NEW UNLESS NOTED OTHERWISE.

C. ALL EXISTING UNDERFLOOR SANITARY SEWER PIPING

BELOW BASEMENT IS BE ABANDONED IN PLACE

UNLESS NOTED OTHERWISE.

D. FIELD VERIFY LOCATION AND SIZE OF EXISTING

CONNECTIONS TO SANITARY SEWER AND DOMESTIC

C H

LI

N

E S

EE

1/

P D

H H

J J

K K

L L

M M

N N

P P

P.1 P.1

MATCH LINE

SEE 1/PD112

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

8:

:0

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

FIRST FLOOR PLUMBING DEMOLITION PLAN

- AREA 1

RDR

BAS

RDR 302

PD111

PD111

KEYPLAN

SCALE: 1/8" = 1'-0"

1 FIRST FLOOR PLUMBING DEMOLITION PLAN - AREA 1

0 4' 8' 16' N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN RISER PIPE TO BE

DEMOLISHED.

GENERAL NOTES

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY SEWER, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING ABOVE BASEMENT

FLOOR TO BE DEMOLISHED AND ALL PLUMBING TO BE

NEW.

C. REFER TO PLANS P-101 THRU P-134 FOR NEW WORK.

M

AT

C H

LI

N

E S

EE

1/

P D

MATCH LINE

SEE 1/PD111

A A

B B

C C

D D

E E

F F

G G

16.1

16.1

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

8:

:1

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

FIRST FLOOR PLUMBING DEMOLITION PLAN

- AREA 2

RDR

BAS

RDR 303

PD112

PD112

KEYPLAN

SCALE: 1/8" = 1'-0"

1 FIRST FLOOR PLUMBING DEMOLITION PLAN - AREA 2

0 4' 8' 16' N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN RISER PIPE TO BE

DEMOLISHED.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY SEWER, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING TO BE DEMOLISHED

AND ALL PLUMBING TO NEW.

SEE 1/PD114

M

AT

C H

LI

N

E S

EE

1/

P D

A A

B B

C C

D D

E E

F F

G G

1 1

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

8:

:2

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

FIRST FLOOR PLUMBING DEMOLITION PLAN

- AREA 3

RDR

BAS

RDR 304

PD113

PD113

KEYPLAN

SCALE: 1/8" = 1'-0"

1 FIRST FLOOR PLUMBING DEMOLITION PLAN - AREA 3

0 4' 8' 16' N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN RISER PIPE TO BE

DEMOLISHED.

3. EXISTING STORM DRAIN PIPE AND RISER TO BE

DEMOLISHED.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY SEWER, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING TO BE

DEMOLISHED AND ALL PLUMBING TO BE NEW.

C H

LI

N

E S

EE

1/

P D

MATCH LINE

SEE 1/PD113

H H

J J

K K

L L

M M

N N

P P

0.9

0.9

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

8:

:2

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

FIRST FLOOR PLUMBING DEMOLITION PLAN

- AREA 4

RDR

BAS

RDR 305

PD114

PD114

KEYPLAN

SCALE: 1/8" = 1'-0"

1 FIRST FLOOR PLUMBING DEMOLITION PLAN - AREA 4 0 4' 8' 16'

N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN RISER PIPE TO BE

DEMOLISHED.

3. EXISTING STORM DRAIN PIPE AND RISER TO BE

DEMOLISHED.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY SEWER, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING TO BE DEMOLISHED

AND ALL PLUMBING TO BE NEW.

C H

LI

N

E S

EE

1/

P D

MATCH LINE

SEE 1/PD122

H H

J J

K K

L L

M M

N N

P P

P.1 P.1

1 1

1 1

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

9:

:4

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

SECOND FLOOR PLUMBING DEMOLITION

PLAN - AREA 1

RDR

BAS

RDR 306

PD121

PD121

KEYPLAN

SCALE: 1/8" = 1'-0"

1 SECOND FLOOR PLUMBING DEMOLITION PLAN - AREA 1

0 4' 8' 16' N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN RISER PIPE TO BE

DEMOLISHED.

3. EXISTING ROOF DRAIN TO BE DEMOLISHED.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY SEWER, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING TO BE

SEE 1/PD121

M

AT

C H

LI

N

E S

EE

1/

P D

A A

B B

C C

D D

E E

F F

G G

16.1

16.1

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

9:

:4

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

SECOND FLOOR PLUMBING DEMOLITION

PLAN - AREA 2

RDR

BAS

RDR 307

PD122

PD122

KEYPLAN

SCALE: 1/8" = 1'-0"

1 SECOND FLOOR PLUMBING DEMOLITION PLAN - AREA 2 0 4' 8' 16'

N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN RISER PIPE TO BE

DEMOLISHED.

3. EXISTING ROOF DRAIN TO BE DEMOLISHED.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY SEWER, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING TO BE DEMOLISHED

SEE 1/PD124

M

AT

C H

LI

N

E S

EE

1/

P D

A A

B B

C C

D D

E E

F F

G G

1 1

1 1

1 1

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

9:

:5

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

SECOND FLOOR PLUMBING DEMOLITION

PLAN - AREA 3

RDR

BAS

RDR 308

PD123

PD123

KEYPLAN

SCALE: 1/8" = 1'-0"

1 SECOND FLOOR PLUMBING DEMOLITION PLAN - AREA 3

0 4' 8' 16' N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN RISER PIPE TO BE

DEMOLISHED.

3. EXISTING ROOF DRAIN TO BE DEMOLISHED.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY SEWER, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING TO BE DEMOLISHED

C H

LI

N

E S

EE

1/

P D

MATCH LINE

SEE 1/PD123

H H

J J

K K

L L

M M

N N

P P

0.9

0.9

1 1

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

9:

:5

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

SECOND FLOOR PLUMBING DEMOLITION

PLAN - AREA 4

RDR

BAS

RDR 309

PD124

PD124

KEYPLAN

SCALE: 1/8" = 1'-0"

1 SECOND FLOOR PLUMBING DEMOLITION PLAN - AREA 4 0 4' 8' 16'

N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN RISER PIPE TO BE

DEMOLISHED.

3. EXISTING ROOF DRAIN TO BE DEMOLISHED.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY SEWER, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING TO BE

C H

LI

N

E S

EE

1/

P D

MATCH LINE

SEE 1/PD132

H H

J J

K K

L L

M M

N N

P P

P.1 P.1

1 1

1 1

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

9:

:0

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

THIRD FLOOR PLUMBING DEMOLITION

PLAN - AREA 1

RDR

BAS

RDR 310

PD131

PD131

KEYPLAN

SCALE: 1/8" = 1'-0"

1 THIRD FLOOR PLUMBING DEMOLITION PLAN - AREA 1 0 4' 8' 16'

N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN RISER PIPE TO BE

DEMOLISHED.

3. EXISTING ROOF DRAIN TO BE DEMOLISHED.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY SEWER, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING TO BE

DN UP

AT

C H

LI

N

E S

EE

1/

P D

MATCH LINE

SEE 1/PD131

A A

B B

C C

D D

E E

F F

G G

16.1

16.1

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

9:

:1

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

THIRD FLOOR PLUMBING DEMOLITION

PLAN - AREA 2

RDR

BAS

RDR 311

PD132

PD132

KEYPLAN

SCALE: 1/8" = 1'-0"

1 THIRD FLOOR PLUMBING DEMOLITION PLAN - AREA 2 0 4' 8' 16'

N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN PIPE AND RISER TO BE

DEMOLISHED.

3. EXISTING ROOF DRAIN TO BE DEMOLISHED.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY SEWER, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING TO BE DEMOLISHED

SEE 1/PD134

M

AT

C H

LI

N

E S

EE

1/

P D

A A

B B

C C

D D

E E

F F

G G

1 1

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

9:

:1

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

THIRD FLOOR PLUMBING DEMOLITION

PLAN - AREA 3

RDR

BAS

RDR 312

PD133

PD133

KEYPLAN

SCALE: 1/8" = 1'-0"

1 THIRD FLOOR PLUMBING DEMOLITION PLAN - AREA 3

0 4' 8' 16' N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN PIPE AND RISER TO BE

DEMOLISHED.

3. EXISTING ROOF DRAIN TO BE DEMOLISHED.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING SANITARY SEWER, VENT, DOMESTIC

WATER STORM DRAIN PIPING TO BE DEMOLISHED AND

ALL PLUMBING TO BE NEW.

SEE 1/PD133

M

AT

C H

LI

N

E S

EE

1/

P D

H H

J J

K K

L L

M M

N N

P P

0.9

0.9

1 1

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

9:

:2

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

THIRD FLOOR PLUMBING DEMOLITION

PLAN - AREA 4

RDR

BAS

RDR 313

PD134

PD134

KEYPLAN

SCALE: 1/8" = 1'-0"

1 THIRD FLOOR PLUMBING DEMOLITION PLAN - AREA 4

0 4' 8' 16' N

GENERAL NOTES

SHEET KEYNOTES

1. EXISTING PLUMBING FIXTURE TO BE DEMOLISHED.

CAP OR REWORK AS REQUIRED FOR NEW

CONSTRUCTION.

2. EXISTING STORM DRAIN RISER PIPE TO BE

DEMOLISHED.

3. EXISTING ROOF DRAIN TO BE DEMOLISHED.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS

AND GENERAL NOTES.

B. ALL EXISTING SANITARY SEWER, VENT, DOMESTIC

WATER AND STORM DRAIN PIPING TO BE

DEMOLISHED AND ALL PLUMBING TO BE NEW.

C. REFER TO PLANS P-101 THRU P-134 FOR NEW

WORK.

DN

DN

DN

DN

H H

J J

K K

L L

M M

N N

P P

P.1 P.1

2" SS UP

TO WCO

4" SS UP

TO WCO

ESP-1

MATCH LINE

SEE 1/P-102

M

AT

C H

LI

N

E S

EE

1/

P -1

NEW

FOUNDATION

(TYP)

SS

SS

4"

4"

2"

2"

2" SS

UP

4" SSD

4" SSD

4" SSD UP

TO FCO

4" SSD

4" EXISTNG SUB-

SURFACE DRAINAGE

ON PERIMETER (TYP)

0108A

0108B 0108C 0108D

0108E

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

:3 9:

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

BASEMENT UNDERFLOOR PLUMBING PLAN

- AREA 1

RDR

BAS

RDR 314

P-101

P-101

KEYPLAN

0 4' 8' 16' N

GENERAL NOTES

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING UNDERFLOOR SANITARY SEWER PIPING

BELOW BASEMENT IS BE ABANDONED IN PLACE

UNLESS NOTED OTHERWISE.

C. FIELD VERIFY LOCATION AND SIZE OF EXISTING

CONNECTIONS TO SANITARY SEWER, SUB-SURFACE

DRAINAGE, VENTS AND DOMESTIC WATER ON SITE

PRIOR TO CONSTRUCTION.

D. SUB-SURFACE DRAINAGE IS TO BE LEFT

UNDISTURBED OR REPAIRED IF BROKEN DURING

INSTALLATION OF NEW SANITARY SEWER PIPING OR

FOUNDATION WORK.

E. REFER TO PLANS P-101 THRU P-134 FOR NEW WORK.

SCALE: 1/8" = 1'-0"

1 BASEMENT UNDERFLOOR PLUMBING PLAN - AREA 1

SHEET KEYNOTES

1. EXISTING SUB-SURFACE DRAINAGE TO REMAIN.

2. EXISTING SUB-SURFACE PERIMETER DRAINAGE TO

REMAIN.

3. CONNECT NEW 4" SSD TO EXISTING AT THIS GENERAL

LOCATION.

BASEMENT AREA 1

Number Name

0101 RR WOMEN

0103 BREAK ROOM

0104 CONFERENCE ROOM

0105 CORRIDOR

0106 OPEN OFFICE

0107 CORRIDOR

0108 OPEN OFFICE

0108A PRIVATE OFFICE

0108B PHONE ROOM

0108C PHONE ROOM

0108D PHONE ROOM

0108E CONFERENCE ROOM

0112 ELEC.

0113 COMM.

0115 COMPUTER WORK

ROOM

DN

DN

A A

B B

C C

D D

E E

F F

G G

16.1

16.1

EXISTING

SUMP PIT

4" SS UP

TO WCO

ESP-3

SP-2

MATCH LINE

SEE 1/P-101

M

AT

C H

LI

N

E S

EE

1/

P -1

SS

SS

4" SS UP

TO FS

3" SS UP

3" UP TO

WCO

4"

4"

4"

3" SS UP

TO WCO

NEW

FOUNDATION

(TYP)

4" SS UP

TO FS

4"

4"

SS

SS

2" SS UP

3"

4" SS UP

TO WCO

EXISTING

DOCK DRAIN

PIPING (TYP)

2"

2"

6"

4" SSD

4" SSD

2" V UP

2" V UP

0211 0208

0203E

0203D

0203C

0203A 0203B

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

:3 9:

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

BASEMENT UNDERFLOOR PLUMBING PLAN

- AREA 2

RDR

BAS

RDR 315

P-102

P-102

KEYPLAN

0 4' 8' 16' N

SCALE: 1/8" = 1'-0"

1 BASEMENT UNDERFLOOR PLUMBING PLAN - AREA 2

GENERAL NOTES

SHEET KEYNOTES

1. SUMP DRAIN PIPING TO REMAIN. ALL SUMP DRAIN

PIPING THAT REMAINS TO BE ROOTED OUT AFTER

CONSTRUCTION TO REMOVE RUST AND BLOCKAGES.

2. EXISTING 6" SUMP DISCHARGE PIPE UP THAT

CONNECTS TO SITE STORM SEWER SYSTEM TO

REMAIN. ROOT OUT AFTER CONSTRUCTION TO

REMOVE RUST AND BLOCKAGES.

3. EXISTING SUB-SURFACE DRAINAGE TO REMAIN.

4. EXISTING SUB-SURFACE PERIMETER DRAINAGE TO

REMAIN.

5. CONNECT NEW 4" SSD TO EXISTING AT THIS GENERAL

LOCATION.

6. 4" SSD UP TO FCO.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING UNDERFLOOR SANITARY SEWER PIPING

BELOW BASEMENT IS BE ABANDONED IN PLACE

UNLESS NOTED OTHERWISE.

C. FIELD VERIFY LOCATION AND SIZE OF EXISTING

CONNECTIONS TO SANITARY SEWER, SUB-SURFACE

DRAINAGE, VENTS AND DOMESTIC WATER ON SITE

PRIOR TO CONSTRUCTION.

D. SUB-SURFACE DRAINAGE IS TO BE LEFT

UNDISTURBED OR REPAIRED IF BROKEN DURING

INSTALLATION OF NEW SANITARY SEWER PIPING OR

FOUNDATION WORK.

E. REFER TO PLANS P-101 THRU P-134 FOR NEW WORK.

BASEMENT AREA 2

Number Name

0201 CORRIDOR

0202 CORRIDOR

0203 OPEN OFFICE

0203A PHONE ROOM

0203B PHONE ROOM

0203C PRIVATE OFFICE

0203D PRIVATE OFFICE

0203E CONFERENCE ROOM

0204 ELEV. EQUIP

0205 SERVICE ELEV

0206 CORRIDOR

0207 CORRIDOR

0208 EXISTING LOADING

DOCK

0209 EXISTING STAIR

0210 EXISTING LAB

0211 STORAGE

0212 RECORD STORAGE

0213 CORR.

0214 STORAGE

0215 STORAGE

0216 EXISTING STORAGE

A A

B B

C C

D D

E E

F F

G G

EXISTING

SUMP PIT

SP-3

SP-4

SP-1

M

AT

C H

LI

N

E S

EE

1/

P -1

MATCH LINE

SEE 1/P-104

SS

SS

SS

2" SS

UP

SS UNDERFLOOR

PIPING TO AVOID

STRUCTURAL

GRADE BEAMS

(TYP)

4" SD

4"

4"

4"

4"

4"

4" SS UP

TO FCO

3" SS UP

TO FCO

3"

4"

SS

4" SS UP

2" SS UP

NEW

FOUNDATION

(TYP)

NEW AREAWAY

3" SS UP

TO FD

EXISTING

SUB-SURFACE

DRAIN PIPE.

(TYP)

2"

SS

SS

SS

2"

2"

4"

SS

SS

4"

4"

2" SS UP

TO FD

2 2

4"

HIGH

POINT

4" SD

3 3

4" SSD

4"

4" SS UP

TO FS

FD

114"

0309 0308

0322A

0322B

3" UP

TO FS

3"

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

:3 9:

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

BASEMENT UNDERFLOOR PLUMBING PLAN

- AREA 3

RDR

BAS

RDR 316

P-103

P-103

KEYPLAN

0 4' 8' 16' N

SCALE: 1/8" = 1'-0"

1 BASEMENT UNDERFLOOR PLUMBING PLAN - AREA 3

GENERAL NOTES

SHEET KEYNOTES

1. CONNECT NEW 4" SANITARY DRAINAGE PIPING TO

EXISTING BELOW BOILER ROOM FLOOR. VERIFY

EXISTING SIZE AND LOCATION PRIOR TO

CONSTRUCTION.

2. EXISTING DRAIN PIPING UNDER EQUIPMENT IN

BOILER ROOM TO REMAIN.

3. EXISTING SUB-SURFACE DRAIN PIPING TO REMAIN.

4. EXISTING SUB-SURFACE PERIMETER DRAINAGE TO

REMAIN.

5. CONNECT NEW 4" SSD TO EXISTING AT THIS

GENERAL LOCATION.

6. 4" SSD UP TO FCO.

7. EXISTING 4" SSD PERIMETER PIPE UP TO CLEANOUT

AT GRADE TO REMAIN.

8. 4" SS UP TO FCO.

9. EXISTING SUMP PUMP DISCHARGE PIPING TO REMAIN.

ALL SUMP DRAIN PIPING THAT REMAINS TO BE

ROOTED OUT AFTER CONSTRUCTION TO REMOVE

RUST AND BLOCKAGES.

10.EXISTING 2" DISCHARGE PIPING UP TO BE

DEMOLISHED ABOVE FINISH FLOOR AND REPLACED

WITH NEW PIPE.

11.4" SS UP TO FS.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING UNDERFLOOR SANITARY SEWER PIPING

BELOW BASEMENT IS BE ABANDONED IN PLACE

UNLESS NOTED OTHERWISE.

C. FIELD VERIFY LOCATION AND SIZE OF EXISTING

CONNECTIONS TO SANITARY SEWER, SUB-SURFACE

DRAINAGE, VENTS AND DOMESTIC WATER ON SITE

PRIOR TO CONSTRUCTION.

D. SUB-SURFACE DRAINAGE IS TO BE LEFT

UNDISTURBED OR REPAIRED IF BROKEN DURING

INSTALLATION OF NEW SANITARY SEWER PIPING OR

FOUNDATION WORK.

E. REFER TO PLANS P-101 THRU P-134 FOR NEW WORK.

BASEMENT AREA 3

Number Name

0301 RR WOMEN

0303 RR MEN

0304 JAN.

0305 EXISTING TEL/COM

0306 CORR.

0308 EXISTING BATTERY

BACK UP

0309 EXISTING ELEC

0310 BREAK ROOM

0311 EXISTING BOILER

0312 ELEC VAULT

0313 AREA-WAY

0314 EXISTING SPRAY

ROOM

0315 EXISTING ELEC

0316 RR WOMEN

0318 SECURE STORAGE

0319 SECURE SHREDDER

0320 CORRIDOR

0321 FOLDER/ INSERTER

0322 STORAGE

0322A SYSTEMS

0322B JAN.

H H

J J

K K

L L

M M

N N

P P

0.9

0.9

ESP-2

M

AT

C H

LI

N

E S

EE

1/

P -1

MATCH LINE

SEE 1/P-103

4" SS UP

2" SS UP

4"

NEW

FOUNDATION

(TYP)

EXISTING

SUB-SURFACE

DRAIN PIPE.

(TYP)

4" SS UP

TO WCO

2" SS

(EXIST)

2" SS

(EXIST)

SS

4" SS

UP

2" SS

UP

4"

4" SS UP

TO FCO

4" SSD

4" SSD

3 3

4" SSD

4" SSD

4" SSD

4" SSD

4" SSD

4" SSD

0419 0421

0416 0417

0425 0427

0419 0421 0422

0416 0417

0425 0427

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

:4 0:

AM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

BASEMENT UNDERFLOOR PLUMBING PLAN

- AREA 4

RDR

BAS

RDR 317

P-104

P-104

KEYPLAN

0 4' 8' 16'

NSCALE: 1/8" = 1'-0"

1 BASEMENT UNDERFLOOR PLUMBING PLAN - AREA 4

GENERAL NOTES

SHEET KEYNOTES

1. CONNECT NEW 4" SANITARY SEWER PIPING TO

EXISTING SS THIS GENERAL AREA. VERIFY EXISTING

SIZE AND LOCATION PRIOR TO CONSTRUCTION.

2. EXISTING SUB-SURFACE DRAIN PIPING TO REMAIN.

3. EXISTING SUB-SURFACE PERIMETER DRAINAGE TO

REMAIN.

4. CONNECT NEW 4" SSD TO EXISTING IN THIS

GENERAL LOCATION.

5. CONNECT NEW 4" SSD PERIMETER DRAINAGE TO

EXISTING TO THIS GENERAL LOCATION.

6. EXISTING 4" SSD PERIMETER UP TO CLEANOUT AT

GRADE TO REMAIN.

7. 4" SSD UP TO WALL CLEANOUT.

A. REFER TO P-001 FOR LEGENDS, ABBREVIATIONS AND

GENERAL NOTES.

B. ALL EXISTING UNDERFLOOR SANITARY SEWER PIPING

BELOW BASEMENT IS BE ABANDONED IN PLACE

UNLESS NOTED OTHERWISE.

C. FIELD VERIFY LOCATION AND SIZE OF EXISTING

CONNECTIONS TO SANITARY SEWER, SUB-SURFACE

DRAINAGE, VENTS AND DOMESTIC WATER ON SITE

PRIOR TO CONSTRUCTION.

D. SUB-SURFACE DRAINAGE IS TO BE LEFT

UNDISTURBED OR REPAIRED IF BROKEN DURING

INSTALLATION OF NEW SANITARY SEWER PIPING OR

FOUNDATION WORK.

E. REFER TO PLANS P-101 THRU P-134 FOR NEW WORK.

BASEMENT AREA 4

Number Name

0401 RR MEN

0402 CORRIDOR

0403 WORK ROOM

0404 EXISTING OFFICE

0405 EXISTING STUDIO

0406 EXISTING OFFICE

0407 PRINT SHOP

0408 EXISTING OFFICE

0409 EXISTING CORRIDOR

0411 EXISTING STUDIO

0412 EXISTING OPEN OFFICE

0413 EXISTING OFFICE

0414 EXISTING WORK AREA

0415 EXISTING OPEN OFFICE

0416 EXISTING OFFICE

0417 EXISTING OFFICE

0418 EXISTING CORRIDOR

0419 EXISTING OFFICE

0421 EXISTING OFFICE

0422 EXISTING CONFERENCE

ROOM

0423 EXISTING CIRCULATION

0425 EXISTING OFFICE

0426 EXISTING. TEL/COM

0427 EXISTING STORAGE

0428 RR MEN

DN

DN

DN

DN

MATCH LINE

SEE 1/P-106

M

AT

C H

LI

N

E S

EE

1/

P -1

H H

J J

K K

L L

M M

N N

P P

P.1 P.1

ESP-1

P-6 P-1

P-2 P-5

P-5

4" SS UP TO TWO-

WAY CLEANOUT AT

GRADE

6" SS. REFER TO CIVIL

PLAN CU101 FOR CONT.

P-401

C W

H W

H W

R

SS

2 1/2"

1 1/2"

3/4"

CW

HW

HWR

3/4"

1 1/2"

2 1/2" 3"

3"

2" 2"

SS PIPING UP

HIGH (TYP)

PCO

4" V

6"

4"

4"

4"

SS

SS

IE= 94'-11"

6" SD UP 6" SD 6" SD

6" SD UP

8" SD

REFER TO CIVIL PLAN

CU101 FOR CONT.

6" SD UP 6" SD

REFER TO CIVIL

PLAN CU101

FOR CONT.

SS

SS

2"

2"

2"

SS UP HIGH (TYP)

2" 3"

SS

6" SD UP

PCO

PCO

PCO

0103 0104

0108A

0108B 0108C

0108D 0108E

8" SD

3"

DESIGNED BY:

DRAWN BY:

WORK ORDER NO.

OFFICE OF

ISSUED BY

DRAWING NO.

DATE

PREPARED BYREVIEWED BY

REV DATE

APPROVED BY

DESCRIPTION

OF

SHEET NO.

APP'DCHECK

FACILITY MANAGEMENT

AMP-400

MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA

FEDERAL AVIATION ADMINISTRATION

DECEMBER 20, 2017

405/840-2931 www.fsb-ae.com

13-007860 AMP-400-E-

FRANKFURT SHORT BRUZA

DEPARTMENT OF TRANSPORTATION

5801 BROADWAY EXT., SUITE 500

OKLAHOMA CITY, OKLAHOMA

Work Request Construction No: 13-007860

MPB-24 (MULTI-PURPOSE BUILDING)

RENOVATION

M.OWENSBY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

S E

D

PRO FES S IO NA L

ENG

IN

EER

/2

0/

:5 0:

PM

C :\U se rs

\rd r\D oc um en ts

\M y

Re vi t\6

_P lb g_ rd r.r vt

BASEMENT FLOOR PLUMBING PLAN -

AREA 1

RDR

BAS

RDR 318

P-105

P-105

SCALE: 1/8" =…