6 2 Drawings 2 of 2.pdf

PDF 37 MB Posted

Attached to
Replace Linear Accelerator at Greater Los Angeles VAHCS Federal contract opportunity
Solicitation number
36C25821B0004
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22

About this file

This solicitation is for replacing a linear accelerator at the Greater Los Angeles Veterans Affairs Health Care System campus in West Los Angeles. The contractor will demolish the existing linear accelerator, prepare the site for installation of a new linear accelerator and Accuray Radixact system to be furnished by the equipment provider. Renovations and construction services are required, including converting a room to a control room, adding a mechanical room and data server room, replacing ceiling, flooring, and rewiring. New lead shielding, air compressor and dryer system, HVAC units, ductwork and ceiling-mounted patient lift must also be installed. Electrical power and controls for the lift, linear accelerator and associated equipment must be provided. Structural bracing, foundation and supports meeting VA, city and state seismic requirements are included. The contractor must coordinate with equipment providers and ensure all existing equipment is removed. The expected construction period is not specified. The soliciting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22.

View the file

Other files for this federal contract opportunity

Other files attached to Replace Linear Accelerator at Greater Los Angeles VAHCS, newest first.
File Type Posted
Sign in Sheet for 11 Jan Site Walk Linear Accelerator.pdf PDF
36C25821B0004 0002.pdf PDF
36C25821B0004 0001 RFI Amendment.pdf PDF
6 8Infection Control Permit_revised.pdf PDF
of0306.pdf PDF
VA0710.pdf PDF
36C25821B0004.pdf PDF
Wage Rate Determination CA20200022.docx DOCX document
Atch 1 Self Performance Calculations.pdf PDF
6 4Radixact Full Set.pdf PDF
Contractor Background Investigation Request Form (May 2019).pdf PDF
6 3Specification CSI 121.pdf PDF
6 1 Drawings1 of 2.pdf PDF
Self Certification of Continuous Service.pdf PDF
Fingerprint Record Prep Sheet BLANK.PDF PDF
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B500 KEY PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

FD-100-1

FIRE PROTECTION DEMO RCP

PLAN - GROUND FLOOR

TRIPLE C - THE A/E GROUP

4401 ATLANTIC AVENUE, SUITE 200

LONG BEACH, CA 90807

562.452.7175

MAT PERKINS

REPLACE LINEAR ACCELERATOR

11301 Wilshire Blvd, West Los Angeles, CA 90073

691-CSI-121

07/29/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

SCALE: 1/4" = 1'-0"

1 GROUND FLOOR DEMOLITION RCP PLAN

1 (E) PENDENT SPRINKLER HEAD TO BE DEMOLISHED.

(E) SIDE WALL SPRINKLER HEAD TO BE DEMOLISHED.

THE HATCHED AREA IS NOT IN SCOPE.

1. ALL EXISTING SPRINKLER HEADS TO BE DEMOLISHED PRIOR

TO DEMOLITION OF CEILING.

Revisions: Date:

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T A

T E O F

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T A

T E O F

No. M35363

M

I K H A I L F U K

S

ME C H A N I C A L

06/30/201906/30/2021

REVISION 1 11/02/20

REVISION 2 11/24/20

7/29/20

Expires 6.30.16Expires: 6/30/1821

7/2 9/2

7/2 9/2

7/2 9/2

7/2 9/2

7/2 9/2

7/2 9/2

7/2 9/2

7/2 9/2

7/2 9/2

7/2 9/2

7/2 9/2

7/2 9/2

7/2 9/2

SYMBOL DESCRIPTION

NOTE CALLOUT

DETAIL CALLOUT

- NUMBER ON TOP DENOTES DETAIL NUMBER

- NUMBER ON BOTTOM DENOTES SHEET DETAIL IS SHOWN

MECHANICAL EQUIPMENT CALLOUT, SEE MECHANICAL PLANS FOR

EXACT LOCATION AND REQUIREMENTS

SECTION CALLOUT

FEEDER CALLOUT

EXISTING FEEDER CALLCOUT

NEW LINEWORK

EXISTING LINEWORK

DEMOLISHED LINEWORK

CONDUIT CONCEALED IN WALL OR ABOVE CEILING

CONDUIT EXPOSED

CONDUIT CONCEALED UNDERGROUND OR BELOW FLOOR

CONDUIT EMERGENCY

CONDUIT TURNED UP

CONDUIT CAPPED

BRANCH CIRCUIT HOMERUN TO PANELBOARD AND CIRCUITS AS

INDICATED

3/4" CONDUIT, TICK MARKS INDICATE QUANTITY OF #12 AWG WIRES

(UNLESS NOTED OTHERWISE, NO MARKS INDICATES 2#12 & 1#12 GND

WIRES)

- SMALL MARK DENOTES HOT WIRE

- LARGE MARK DENOTES NEUTRAL WIRE

- DIAGONAL DENOTES GROUND WIRE

GENERATOR

SWITCH

CIRCUIT BREAKER

2-WAY SWITCH, TRANSFER SWITCH

FUSE

TRANSFORMER

GROUND CONNECTION

MOTOR - SINGLE PHASE FRACTIONAL OR INTEGRAL HORSEPOWER

METER

ELECTRONIC CIRCUIT MONITOR

480V DRAWOUT BREAKER

VARIABLE FREQUENCY DRIVE

FUSED DISCONNECT SWITCH

NON-FUSED DISCONNECT SWITCH

COMBINATION STARTER/DISCONNECT SWITCH

SWITCH MOTOR RATED

SPLICE

TERMINATION

EXISTING TERMINATION

MEDIUM VOLTAGE - AIR CIRCUIT BREAKER

DRAWOUT BREAKER

MEDIUM VOLTAGE FUSED

DISCONNECT SWITCH

MEDIUM VOLTAGE MODULAR SPLICE

MEDIUM VOLTAGE EXISTING MODULAR SPLICE

2X4 LIGHT FIXTURE - UPPER CASE LETTER INDICATES LIGHT FIXTURE

CALLOUT. LOWER CASE LETTER INDICATES LIGHTING CONTROL ZONE.

2X4 EMERGENCY LIGHT FIXTURE FED FROM GENERATOR/ INVERTER/

BATTERY BACKUP

2X2 LIGHT FIXTURE - UPPER CASE LETTER INDICATES LIGHT FIXTURE

CALLOUT. LOWER CASE LETTER INDICATES LIGHTING CONTROL ZONE.

2X2 EMERGENCY LIGHT FIXTURE FED FROM GENERATOR/ INVERTER/

BATTERY BACKUP

LINEAR LIGHT FIXTURE, DIMENSIONS PER PLANS - UPPER CASE LETTER

INDICATES LIGHT FIXTURE CALLOUT. LOWER CASE LETTER INDICATES

LIGHTING CONTROL ZONE.

EMERGENCY LINEAR LIGHT FIXTURE, DIMENSIONS PER PLANS - LIGHT

FIXTURE FED FROM GENERATOR/ INVERTER/ BATTERY BACKUP

LINEAR PENDANT LIGHT FIXTURE, DIMENSIONS PER PLANS - UPPER

CASE LETTER INDICATES LIGHT FIXTURE CALLOUT. LOWER CASE

LETTER INDICATES LIGHTING CONTROL ZONE.

TRACK LIGHTING - UPPER CASE LETTER INDICATES LIGHT FIXTURE

CALLOUT. LOWER CASE LETTER INDICATES LIGHTING CONTROL ZONE.

UNDERCABINET / COVE FIXTURE - UPPER CASE LETTER INDICATES

LIGHT FIXTURE CALLOUT. LOWER CASE LETTER INDICATES LIGHTING

CONTROL ZONE.

SYMBOL DESCRIPTION

DOWNLIGHT FIXTURE - UPPER CASE LETTER INDICATES LIGHT FIXTURE

CALLOUT. LOWER CASE LETTER INDICATES LIGHTING CONTROL ZONE.

EMERGENCY DOWNLIGHT FIXTURE FED FROM GENERATOR/ INVERTER/

BATTERY BACKUP

PENDANT LUMINAIRE - UPPER CASE LETTER INDICATES LIGHT FIXTURE

CALLOUT. LOWER CASE LETTER INDICATES LIGHTING CONTROL ZONE.

WALLWASH LIGHT FIXTURE - UPPER CASE LETTER INDICATES LIGHT

FIXTURE CALLOUT. LOWER CASE LETTER INDICATES LIGHTING

CONTROL ZONE.

WALL MOUNTED LIGHT FIXTURE - UPPER CASE LETTER INDICATES

LIGHT FIXTURE CALLOUT. LOWER CASE LETTER INDICATES LIGHTING

CONTROL ZONE.

EMERGENCY WALL MOUNTED LIGHT FIXTURE FED FROM GENERATOR/

INVERTER/ BATTERY BACKUP

IN GRADE LUMINAIRE

PATHWAY LUMINAIRE

LANDSCAPE FIXTURE

EXIT LIGHT FIXTURE WITH DIRECTIONAL ARROWS AS INDICATED.

SHADED SIDE DENOTES NUMBER OF FACES

JUNCTION BOX

PHOTOCELL FOR EXTERIOR APPLICATIONS

DAYLIGHT SENSOR - CEILING MOUNTED

RELAY

EMERGENCY RELAY UL 924 COMPLIANT

MOTION SENSOR - CEILING MOUNTED

MOTION SENSOR - CORNER OR WALL MOUNTED

MOTION SENSOR WITH AISLE/CORRIDOR LENS - CEILING MOUNTED

COMBINATION MOTION AND DAYLIGHT SENSOR

LIGHTING CONTROL NETWORK DEVICE

DIGITAL TIMER SWITCH

MOTION SENSOR SWITCH

LOW VOLTAGE SWITCH

DIMMER MASTER SWITCH

DIGITAL DIMMING SWITCH

GRAPHICAL TOUCH SCREEN - LIGHTING CONTROL STATION

THERMOSTAT WITH A 3/4" CONDUIT TO ACCESSIBLE CEILING SPACE

MODULAR FURNITURE - BASE POWER WHIP FEED CONNECTION

MODULAR FURNITURE - FLOOR BOX FEED CONNECTION

MODULAR FURNITURE - POWER POLE FEED CONNECTION

LIGHTING CONTROL PANEL - SURFACE MOUNTED

PANELBOARD - RECESSED MOUNTED

PANELBOARD - SURFACE MOUNTED

DISTRIBUTION PANEL/ BOARD

SINGLE POLE SWITCH, DEVICE SHALL BE MOUNTED +48" MAX AND +36"

MIN FROM THE CENTER OF DEVICE:

SWITCH 3-WAY (48" AFF MAXIMUM)

TIMER SWITCH (48" AFF MAXIMUM)

DUAL SWITCH (48" AFF MAXIMUM)

PUSHBUTTON SWITCH

RECESSED ON WALL G=GFCI, WP=WEATHER PROOF

SURFACE G=GFCI, WP=WEATHER PROOF

FLOOR OR CEILING C=CEILING

20A, 125V DUPLEX RECEPTACLE

MOUNTED +15" AFF, UNLESS OTHERWISE NOTED

20A, 125V QUAD RECEPTACLE

MOUNTED +15" AFF, UNLESS OTHERWISE NOTED

20A, 125V DUPLEX RECEPTACLE

RECEPTACLE ON DEDICATED CIRCUIT

20A, 125V CONTROLLED DUPLEX RECEPTACLE

20A, 125V QUAD RECEPTACLE

(HALF) CONTROLLED RECEPTACLE

SPECIAL RECEPTACLE

REFER TO DRAWINGS FOR NEMA CONFIGURATION

JUNCTION BOX

RECESSED POKE-THROUGH

RECESSED POKE-THROUGH - POWER/TEL/DATA

RECESSED FLOOR BOX - POWER/TEL/DATA

20A, 125V DUPLEX RECEPTACLE FIRE RATED TYPE

20A, 125V QUAD RECEPTACLE FIRE RATED TYPE

W W MULTI-CHANNEL RACEWAY

ABBREVIATIONSLEGEND

SHEET INDEX

A-1

G

M

ECM

VFD

X y

X y

X y

X y

X y

X y

X y

X y

X y

X y

X y

J

PC

DS

R

ER

M

M

M

MD

N

TM

MS

LV

DM

D

G

T

J

J

JJJ

M ab

T

J

SCOPE OF WORK

1. ELECTRICAL DESIGN TO SUPPORT INSTALLATION OF NEW LINEAR ACCELERATOR AND SUPPORT AREAS.

2. DEMOLITION OF EXISTING ELECTRICAL CONNECTIONS AND SUPPORT AREAS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

E-001

GENERAL NOTES, LEGEND,

ABBREVIATIINS AND SHEET INDEX

TRIPLE C - THE A/E GROUP

4401 ATLANTIC AVENUE, SUITE 200

LONG BEACH, CA 90807

562.452.7175

MAT PERKINS

REPLACE LINEAR ACCELERATOR

11301 Wilshire Blvd, West Los Angeles, CA 90073

691-CSI-121

07/29/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

ABBREVIATION DESCRIPTION

LF LINEAR FEET

LFMC LIQUIDTIGHT FLEXIBLE METAL CONDUIT

LGST LARGEST

LIS LOAD INTERRUPTER SWITCH

LOC. LOCATION

LOTO LOCK-OUT & TAG-OUT

LSI LONG TERM, SHORT TERM,

INSTANTANEOUS

LTG LIGHTING

LV LOW VOLTAGE

M METER

MAX MAXIMUM

MCA MINIMUM CIRCUIT AMPS

MCC MOTOR CONTROL CENTER

MCP MOTOR CIRCUIT PROTECTOR

MFGR, MFR MANUFACTURER

MH MANHOLE

MI. MECHANICAL INTERLOCK

MIN MINIMUM

MOCP MAXIMUM OVERCURRENT PROTECTION

MRCT MULTI-RATIO CURRENT TRANSFORMER

MTD MOUNTED

MTG MOUNTING

MTR MOTOR

MTTB MAIN TELEPHONE TERMINAL BOARD

MV MEDIUM VOLTAGE

N NORTH

NAC NOTIFICATION APPLIANCE CIRCUIT

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NF NON-FUSED

NIC NOT IN CONTRACT

NL NIGHT LIGHT- 24HRS ON

NO. NUMBER

OC ON CENTER

OCPD OVERCURRENT PROTECTIVE DEVICE

OD OUTSIDE DIAMETER

OE OVERHEAD ELECTRICAL

OFC OIL FUSED CUTOUT

OH OVER HEAD

OL OIL LEVER SWITCH

P POLE

PAC PROGRAMMABLE AUTOMATION

CONTROLLER

PB PULL BOX

PC PHOTOCELL

PCB POLYCHLORINATED BIPHENYL

PDS PRESSURE DIFFERENTIAL SWITCH

PF POWER FACTOR

PH OR Ø PHASE

PILC PAPER INSULATED, LEAD COVER

PIV POST INDICATING VALVE

PL PLATE

PLC PROGRAMMABLE LOGIC CONTROLLER

PNL PANEL

POC POINT OF CONNECTION

PREF. PREFERRED

PRI. PRIMARY

PVC POLY-VINYL CHLORIDE

PWR POWER

REC/RECEPT RECEPTACLE

REQ'D REQUIRED

RGS RIGID GALVANIZED STEEL

RM ROOM

RMC RIGID METAL CONDUIT

RPBP REDUCED PRESSURE BACK FLOW

PREVENTER

RTAC REAL TIME

SCCR SHORT CIRCUIT CURRENT RATING

SCE SOUTHERN CALIFORNIA EDISON

SF SQUARE FEET

SHT SHEET

SIG. SIGNAL

SP SPARE

SPECS SPECIFICATIONS

ST STREET

STD STANDARD

STP SHIELDED TWISTED PAIR

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

SWST SWITCHING STATION

T.O.D. TOP OF DUCTBANK

T.O.M. TOP OF MANHOLE

TB TERMINAL BLOCK

TEL./TELE TELEPHONE

TMH TELEPHONE MANHOLE

TPS TWISTED SHIELDED PAIR

TRANSF, XFMR TRANSFORMER

TS TAMPER SWITCH

TYP TYPICAL

UG UNDERGROUND

UON UNLESS OTHERWISE NOTED

V VOLTS

VA VOLT-AMPERES

VB VIBRATION SWITCH

VFD VARIABLE FREQUENCY DRIVE

W WATTS

W/ WITH

W/O WITHOUT

WP WEATHERPROOF

Z IMPEDANCE

ABBREVIATION DESCRIPTION

& AND

1/C SINGLE CONDUCTOR

@ AT

A OR AMP AMPERES

A.C. ASPHALT CONCRETE

ABV ABOVE

AF AMPERE FUSE RATING

AFC AVAILABLE FAULT CURRENT

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISH GRADE

AIC AMPERE INTERRUPTING CAPACITY

AL ALUMINUM

APPROX. APPROXIMATE

ARCH. ARCHITECT; ARCHITECTURAL

AS AMPERE SWITCH RATING

ASCC AVAILABLE SHORT CIRCUIT CURRENT

ATC AIR TERMINAL CHAMBER

ATO AUTOMATIC THROW-OVER (SWITCH)

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AWG AMERICAN WIRE GAUGE

B.S. BARE STRANDED

BAT BATTERY

BEL BELOW

BKBD BACKBOARD

BKR BREAKER

BLDG BUILDING

C CONDUIT

C.O. CONDUIT ONLY WITH PULL WIRE

CB CIRCUIT BREAKER

CC CONSTANT CURRENT

CKT CIRCUIT

CL CENTER LINE

CLG CEILING

CMU CONCRETE MASONRY UNIT

COL COLUMN

CP COMMUNICATION PROCESSOR

CPT CONTROL POWER TRANSFORMER

CR CONTROL RELAY

CSFD COMBINATION SMOKE FIRE DAMPER

CT CURRENT TRANSFORMER

CU COPPER

CW COLD WATER

DIAG DIAGRAM

DIS DISCONNECT

DIST. DISTANCE

DL DAMP LOCATION LISTING

DM DIGITAL METER

DMM DIGITAL METER MODULE

DP DISTRIBUTION PANEL

DWG DRAWING

DWP DEPARTMENT OF WATER & POWER

EA EACH

ECM ELECTRIC CIRCUIT MONITOR

ELEC. ELECTRICAL

EM EMERGENCY

EMH ELECTRICAL MANHOLE

EMT ELECTRICAL METALLIC TUBING

EPO EMERGENCY POWER OFF

EPR ETHYLENE PROPYLENE RUBBER

EQUIP EQUIPMENT

ERR EXISTING TO BE RELOCATED AND

RECONNECTED

EXIST/(E) EXISTING

EXP EXPLOSION PROOF

FA FIRE ALARM

FACP FIRE ALARM CONTROL PANEL

FATC FIRE ALARM TERMINAL CABINET

FFE FINISHED FLOOR ELEVATION

FIN. FINISH

FIP. FIELD INTERFACE PANEL

FIXT FIXTURE

FLA FULL LOAD AMPS

FLR FLOOR

FLUOR FLUORESCENT

FMC FLEXIBLE METAL CONDUIT

FO FIBER OBTIC

FT FEET

FTG FOOTING

GEN GENERATOR

GFI GROUND FAULT INTERRUPTER

GFR GROUND FAULT RELAY

GG GREEN GROUND

GND GROUND

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HT HEIGHT

HTR HEATER

HV HIGH VOLTAGE

HZ HERTZ

ICON INTEGRATED COMMUNICATIONS OPTICAL

NETWORK

IE INVERT ELEVATION

IED INTELLEGENT ELECTRONIC DEVICE

IMC INTERMEDIATE METAL CONDUIT

INCAND INCADESCENT

ISC SHORT CIRCUIT CURRENT

J, JB, J-BOX JUNCTION BOX

KCMIL THOUSAND CIRCULAR MILS

KV KILOVOLT

KVA KILOVOLT-AMPERES

KW KILOWATT

SHEET DESCRIPTION

IN THE EVENT ABBREVIATIONS NOT MENTIONED HEREIN ARE USED, REFERENCE WILL BE MADE TO ANSI Y1.1, MILITARY

STANDARD ABBREVIATIONS AND OTHER STANDARD INDUSTRY CONVENTIONS.

Revisions: Date:

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

No. E17012

PA

T R

I CK WA LDENFELS

09/30/2021

E L E C T R I C A L

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

E-002

NOTES

TRIPLE C - THE A/E GROUP

4401 ATLANTIC AVENUE, SUITE 200

LONG BEACH, CA 90807

562.452.7175

MAT PERKINS

REPLACE LINEAR ACCELERATOR

11301 Wilshire Blvd, West Los Angeles, CA 90073

691-CSI-121

07/29/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

GENERAL NOTES

ALL WORK SHALL COMPLY WITH THE 2019 NATIONAL ELECTRICAL CODE, AND ALL OTHER APPLICABLE

FEDERAL AND STATE. WHERE THE CONSTRUCTION DOCUMENTS INDICATE MORE RESTRICTIVE

REQUIREMENTS, THE CONSTRUCTION DOCUMENTS SHALL GOVERN BUT THE CONSTRUCTION DOCUMENTS

SHALL NOT BE INTERPRETED AS AUTHORITY TO VIOLATE ANY CODE OR REGULATION.

ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND SHALL BEAR THE UNDERWRITERS' LABEL (UL)OR OTHER NATIONALLY RECOGNIZED TESTING LABORATORY THAT IS ACCEPTABLE TO THE CITY OF L.A. AND

SHALL BE INSTALLED IN THE MANNER FOR WHICH THEY ARE DESIGNED AND APPROVED.

THE CONTRACTOR SHALL NOT BORE, NOTCH OR IN ANY WAY CUT INTO ANY STRUCTURAL MEMBER

WITHOUT WRITTEN APPROVAL FROM THE STRUCTURAL ENGINEER.

MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT ANCHORAGE NOTES:

ALL MECHANICAL, PLUMBING, AND ELECTRICAL COMPONENTS SHALL BE ANCHORED AND INSTALLED PER THE DETAILS ON THE APPROVED CONSTRUCTION DOCUMENTS. WHERE NO DETAIL IS INDICATED, THE FOLLOWING COMPONENTS SHALL BE ANCHORED OR BRACED TO MEET THE FORCES AND DISPLACEMENT

REQUIREMENTS.

A. ALL PERMANENT EQUIPMENT AND COMPONENTS.

B. TEMPORARY OR MOVABLE EQUIPMENT THAT IS PERMANENTLY ATTACHED (E.G. HARD WIRED) TO THE

BUILDING UTILITY SERVICES SUCH AS ELECTRICITY, GAS OR WATER.

C. MOVABLE EQUIPMENT WHICH IS STATIONED IN ONE PLACE FOR MORE THAN 8 HOURS AND HEAVIER

THAN 400 POUNDS ARE REQUIRED TO BE ANCHORED WITH TEMPORARY ATTACHMENTS.

THE ATTACHMENT OF THE FOLLOWING MECHANICAL AND ELECTRICAL COMPONENT SHALL BE POSITIVELY ATTACHED TO THE STRUCTURE, BUT NEED NOT BE DETAILED ON THE PLANS. THESE COMPONENTS SHALL HAVE FLEXIBLE CONNECTIONS PROVIDED BETWEEN THE COMPONENT AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT.

A. COMPONENTS WEIGHING LESS THAN 400 POUNDS AND HAVE A CENTER OF MASS LOCATED 4 FEET OR LESS ABOVE THE ADJACENT FLOOR OR ROOF LEVEL THAT DIRECTLY SUPPORTS THE COMPONENT.

B. COMPONENTS WEIGHING LESS THAN 20 POUNDS, OR IN THE CASE OF DISTRIBUTED SYSTEMS, LESS THAN 5 POUNDS PER FOOT, WHICH ARE SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A WALL.

FOR THOSE ELEMENTS THAT DO NOT REQUIRE DETAILS ON THE APPROVED DRAWINGS, THE INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER OF RECORD AND THE STRUCTURAL ENGINEER. THE PROJECT INSPECTOR WILL VERIFY THAT ALL COMPONENTS AND EQUIPMENT HAVE BEEN

ANCHORED IN ACCORDANCE WITH ABOVE REQUIREMENTS.

PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEM BRACING NOTES:

PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO COMPLY WITH THE

FORCES AND DISPLACEMENTS PRESCRIBED IN LATEST SECTIONS OF CBC AND ASCE.

THE BRACING AND ATTACHMENTS TO THE STRUCTURE SHALL BE DETAILED ON THE APPROVED DRAWINGS.

COPIES OF THE MANUAL SHALL BE AVAILABLE ON THE JOBSITE PRIOR TO THE START OF HANGING AND

BRACING OF THE PIPE, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS.

THE STRUCTURAL ENGINEER OF RECORD SHALL VERIFY THE ADEQUACY OF THE STRUCTURE TO SUPPORT

THE HANGER AND BRACE LOADS.

OBTAIN BUILDING AND LICENSING PERMITS AND PAY ASSOCIATED COSTS AND EXPENSES REQUIRED BY

FEDERAL, STATE, AND LOCAL AGENCIES.

VISIT THE SITE INCLUDING AREAS INDICATED ON THE DRAWINGS. OBTAIN AND INSPECT CONTRACT DOCUMENTS IMMEDIATELY UPON RECEIPT INCLUDING CONTRACT DOCUMENTS OF OTHER DISCIPLINES.

NOTIFY OWNER OF DISCREPANCIES WITHIN 24 HOURS.

SUBMIT A CHANGE ORDER TO THE OWNER DETAILING AND SPECIFYING REQUIRED WORK AND OBTAIN

APPROVAL BEFORE PROCEEDING WITH WORK WHERE CONDITIONS DEVELOP NOT COVERED BY THE

CONTRACT DOCUMENTS OR WHERE FINISHED WORK WILL NOT COMPLY WITH TITLE 24, CALIFORNIA

CODE OF REGULATIONS (CCR).

COORDINATE AND SCHEDULE WORK WITH OTHER TRADES AND OWNER.

MAINTAIN RECORD DRAWINGS DAILY TO REFLECTING CHANGES MADE TO THE CONTRACT DOCUMENTS DURING CONSTRUCTION. IDENTIFY AND DIMENSION UNDERGROUND CONDUIT LOCATIONS AND DEPTHS.

PROVIDE CONNECTION AND TERMINATION TO OWNER FURNISHED EQUIPMENT COMPLIANT WITH THE

LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTALLATION REQUIREMENTS AND

RECOMMENDATIONS.

NOTIFY OWNER 48 HOURS PRIOR TO PROJECT COMPLETION TO ALLOW FOR OWNER'S INSPECTION OF

WORK. PROVIDE COMPETENT PERSONNEL TO ASSIST AND DEMONSTRATE EQUIPMENT OR SYSTEM

OPERATION. FINAL ACCEPTANCE OF WORK BY THE OWNER WILL BE AFTER APPROVAL AND ACCEPTANCE

BY AHJ.

FURNISH A ONE-YEAR WRITTEN GUARANTEE FOR MATERIALS AND WORKMANSHIP FROM THE DATE OF

SUBSTANTIAL COMPLETION.

PROVIDE AND MAINTAIN REQUIRED WORKING SPACE, DEDICATED EQUIPMENT SPACE, AND EGRESS

REQUIREMENTS PER NEC 110.26.

INSTALL CONDUITS AND EQUIPMENT PLUMB AND LEVEL. ROUTE CONDUITS PARALLEL TO WALLS AND OTHER PIPING. PROVIDE CONDUIT OFF-SETS AND SADDLES TO AVOID OBSTACLES, MAINTAIN CONDUIT

PATHWAYS, AND PROVIDE CLEARANCES.

PROVIDE FIELD BENDS FOR EMT AND RIGID CONDUIT 1 INCH AND SMALLER. DO NOT KINK OR REDUCE

CROSS SECTIONAL AREA OF CONDUIT. USE BENDING EQUIPMENT APPROVED BY THE CONDUIT

MANUFACTURER. REPAIR SCRATCHES AND MARS WITH CONDUIT MANUFACTURER APPROVED PRODUCT.

AVOID CUTTING OR DAMAGING REINFORCING BARS OR TENDONS WHEN CORING OR WHEN INSTALLING DRILLED-IN ANCHORS OR POWDER DRIVEN PINS IN REINFORCED CONCRETE. LOCATE BARS AND PRE- STRESSED (PRE- OR POST-TENSIONED) TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO CORING OR INSTALLATION OF ANCHORS OR PINS. MAINTAIN MINIMUM CLEARANCE OF ONE INCH BETWEEN

REINFORCEMENT AND CORED HOLE OR DRILLED-IN ANCHOR OR PIN. COORDINATE ANY WORK IN

REINFORCED CONCRETE WITH SEOR PRIOR TO ROUGH-IN.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

CONTRACTOR SHALL FIELD DEVELOP THE CONDUIT INSTALLATION ALONG ROUTE SHOWN ON PLANS WITH PULLBOXES AND/OR LB FITTINGS INSTALLED EVERY 270 DEGREES (MAXIMUM) OF CONDUIT BENDS TO AVOID OBSTRUCTIONS. PROVIDE FIRE-RATED PENETRATIONS FOR ALL FIRE RATED WALLS AND FLOORS TO

MATCH OR EXCEED THE RATING OF WALL OR FLOOR.

PROVIDE FIRE-RATED PUTTY PADS ON ALL NEW ELECTRICAL OUTLET BOXES LOCATED IN RATED WALLS.

FUSES TO BE PROVIDED WITH REJECTION TYPE FUSE HOLDERS.

ALL CONDUITS PENETRATING CONCRETE FLOORS OR WALLS SHALL BE COORDINATED WITH SEOR PRIOR TO

COMENCEMENT OF WORK.

COMPLY WITH ARTICLE 517.13 (A) AND (B) - WIRING METHOD FOR GROUNDING OF RECEPTACLES AND FIXED ELECTRIC EQUIPMENT IN PATIENT CARE AREAS: ALL BRANCH CIRCUITS SERVING PATIENT AREA AREAS SHALL BE PROVIDED WITH A GROUND PATH FOR FAULT CURRENT BY INSTALLATION IN A METAL RACEWAY SYSTEM, OR A CABLE HAVING A METALLIC ARMOR OR SHEATH ASSEMBLY. THE METAL RACEWAY SYSTEM, OR METALLIC CABLE ARMOR, OR SHEATH ASSEMBLY SHALL ITSELF QUALIFY AS AN EQUIPMENT GROUNDING

RETURN PATH IN ACCORDANCE WITH 250.118.

COMPLY WITH ARTICLE 517.13(A) AND (B) - PATIENT CARE RECEPTACLE REQUIREMENTS: THE GROUNDING TERMINALS OF ALL RECEPTACLES AND ALL NON-CURRENT CARRYING CONDUCTIVE SURFACES IN PATIENT CARE AREAS SHALL BE GROUNDED BY AN INSULATED COPPER CONDUCTOR. PER SECTION 517.13(B).

ALL RECEPTACLES IN PATIENT CARE AREAS SHALL BE HOSPITAL GRADE.

33.

34.

35.

36.

37.

38.

39.

OBTAIN WRITTEN PERMISSION FROM THE STRUCTURAL ENGINEER PRIOR TO USE OF POWER DRIVEN PINS.

ORDER EQUIPMENT IN SPLITS SIZED TO ALLOW ENTRY INTO BUILDING AND SPACE.

COORDINATE AND SCHEDULE INTERRUPTIONS OF ELECTRICAL POWER WITH OWNER IN WRITING MINIMUM TWO WEEKS IN ADVANCE AND AT TIMES CONVENIENT TO THE OWNER. INCLUDE COST OF PREMIUM TIME

WORK IN BID.

CUT AND PATCH EXISTING CEILINGS AND WALLS WHERE SPECIFIED FOR INSTALLATION OF CONDUIT, OUTLET BOXES, SUPPORTS, AND EQUIPMENT. REPAIR CEILINGS AND WALLS TO MATCH EXISTING

INSTALLATION.

REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATIONS OF CEILING MOUNTED EQUIPMENT.

REFER TO ARCHITECTURAL FLOOR AND ELEVATION PLANS FOR DEVICE AND OUTLET LOCATIONS. LOCATE COUNTERTOP OUTLETS 6 INCHES ABOVE BACKSPLASH. DO NOT SCALE DEVICE AND OUTLET LOCATIONS

FROM ELECTRICAL PLANS.

VERIFY ACTUAL CONNECTION LOCATIONS OF PLUMBING AND MECHANICAL EQUIPMENT WITH EQUIPMENT

SHOP DRAWINGS. COORDINATE EXACT DISCONNECT LOCATION WITH PLUMBING AND MECHANICAL

CONTRACTORS. LOCATE ROOF PENETRATIONS AND DISCONNECT SWITCHES TO PROVIDE CODE REQUIRED CLEARANCES, ACCESS, AND LINE OF SIGHT TO EQUIPMENT. INSTALL DISCONNECT SWITCHES 30 INCHES

MINIMUM ABOVE ROOF. PROVIDE ANGLE GALVANIZED STEEL SUPPORT STRUCTURE.

CONTRACTOR TO USE FIRE BARRIER MOLDABLE PUTTY ON ELECTRICAL BOXES LOCATED IN RATED WALLS.

PROVIDE TESTED FIRE STOPPING ASSEMBLY APPROVED BY THE AHJ FOR CONDUIT PENETRATIONS OF FIRE

RATED WALLS, FLOORS, AND CEILINGS.

PROVIDE GROUNDING CONDUCTOR WITH FEEDERS AND BRANCH CIRCUITS SIZED PER CEC 250.122.

PROVIDE 3 FEET MAXIMUM LIQUIDTIGHT FLEXIBLE METAL CONDUIT (LFMC) CONNECTION TO

TRANSFORMERS AND VIBRATING EQUIPMENT. USE ARMORED CABLE OR BARE CONDUCTOR, WHERE NOT

SUBJECT TO PHYSICAL DAMAGE (4 AWG OR LARGER), FOR GROUNDING ELECTRODE CONDUCTOR

TRANSFORMER CONNECTIONS. REFERENCE NEC 250.64.

COORDINATE WORK WITH OTHER DISCIPLINES TO ALLOW FOR PHASED INSTALLATION. SCHEDULE AND

PERFORM CONSTRUCTION TO MINIMIZE AND AVOID IMPACTS TO ADJOINING SPACES.

PROVIDE COPPER CONDUCTORS. USE TYPE XHHW-2 CONDUCTOR INSULATION UNDERGROUND EXTERIOR TO BUILDING AND ON ROOF TOPS. USE TYPE THHN/THWN-2 CONDUCTOR INSULATION ABOVE GRADE EXTERIOR TO BUILDING AND UNDERGROUND INTERIOR TO BUILDING. USE TYPE THHN/THWN CONDUCTOR

INSULATION ABOVE GRADE INTERIOR TO BUILDING.

USE CIRCUITS WITH DEDICATED NEUTRALS FOR BRANCH CIRCUITS. MULTIWIRE BRANCH CIRCUITS ARE NOT

ALLOWED.

PROVIDE INSTALLATION IN PATIENT CARE AREAS USING CONDUIT APPROVED AS A GROUND RETURN

BACKBOXES IN COMMON WALLS OF PATIENT CARE AREAS.

PROVIDE RIGID METAL CONDUIT FOR EXPOSED CONDUITS BELOW 8 FEET ABOVE FINISHED FLOOR.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

27.

28.

29.

31.

32.

WORK INCLUDED: ALL LABOR, MATERIAL, APPLIANCES, TOOLS, EQUIPMENT, FACILITIES, TRANSPORTATION AND SERVICES NECESSARY AND INCIDENTAL TO PERFORMING ALL OPERATIONS IN CONNECTION WITH THE

DEMOLITION, DISPOSAL, TRANSPORTATION AND RECONNECTION OF EXISTING REMAINING

EQUIPMENT/DEVICES. COMPLETE AS INDICATED IN THE CONTRACT DOCUMENTS AS SPECIFIED HEREIN.

THE FOLLOWING IS INTENDED TO COVER THE COMPLETE DEMOLITION, DISPOSAL, TRANSPORTATION AND RECONNECTION OF EXISTING ELECTRICAL EQUIPMENT. THE OMISSION OF EXPRESSED REFERENCE TO ANY ITEM OF LABOR OR MATERIAL FOR THE PROPER EXECUTION OF THE WORK IN ACCORDANCE WITH PRESENT PRACTICE OF THE TRADE SHALL NOT RELIEVE THE CONTRACTOR FROM PROVIDING SUCH ADDITIONAL

LABOR AND MATERIALS.

REFER TO THE CONTRACT DOCUMENTS FOR ADDITIONAL DEMOLITION REQUIREMENTS WHICH AFFECT THE PROPER EXECUTION OF THIS WORK. DIAGRAMS AND SYMBOLS SHOWING ELECTRICAL CONNECTIONS ARE

DIAGRAMMATIC ONLY. WIRING DIAGRAMS DO NOT NECESSARILY SHOW THE EXACT PHYSICAL

ARRANGEMENT OF THE EQUIPMENT.

IT IS THE CONTRACTOR'S RESPONSIBILITY TO VISIT THE SITE AND BECOME THOROUGHLY FAMILIAR WITH ALL FEATURES OF THE BUILDING AND SITE WHICH MAY AFFECT THE PROPER PERFORMANCE OF THIS WORK.

PORTIONS OF THESE PLANS HAVE BEEN DERIVED FROM INFORMATION TAKEN FROM ORIGINAL ELECTRICAL PLANS. THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO PROVIDE FOR THE REMOVAL AND DISPOSAL OF ALL ELECTRICAL EQUIPMENT, LIGHTING FIXTURES, DEVICES, OUTLET BOXES, CONDUIT, WIRING, ETC. AS DEFINED HEREIN AND AS INDICATED ELSEWHERE IN THE CONTRACT DOCUMENTS.

IT IS UNDERSTOOD AND AGREED THAT THIS CONTRACT DOES NOT CONTEMPLATE THE HANDLING OF ASBESTOS, PCB OR ANY HAZARDOUS WASTE MATERIAL. IF ASBESTOS, PCB OR ANY HAZARDOUS WASTE MATERIAL IS ENCOUNTERED, NOTIFY THE ELECTRICAL ENGINEER IMMEDIATELY. DO NOT DISTURB, HANDLE

OR ATTEMPT TO REMOVE.

THE SCOPE OF DEMOLITION WORK SHALL INCLUDE, BUT IS NOT LIMITED TO THE FOLLOWING:

A. SUBMIT PROPOSED OUTAGE SCHEDULE. PROVIDE A SEQUENCE OF DEMOLITION TO INSURE

THE UNINTERRUPTED USE OF OCCUPIED PORTIONS OF THE FACILITY WHICH ARE TO

REMAIN OPERATIONAL DURING THE CONTRACT PERIOD.

B. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER, IN WRITING.

WORK WHICH COULD RESULT IN A ACCIDENTAL OUTAGE (BEYOND BRANCH CIRCUITS)

SHALL BE PERFORMED WITH THE OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH

WORK.

1) COORDINATE WITH THE OWNER AND DESIGNATE A PORTION OF THE

FACILITY FOR SAFELY STORING ALL REMOVED AND SALVAGED MATERIALS.

C. ALL REMOVED MATERIALS AND EQUIPMENT WHICH IN THE OPINION OF THE

OWNER/ARCHITECT ARE SALVAGEABLE, SHALL REMAIN THE PROPERTY OF THE OWNER.

DELIVER SUCH SALVAGED MATERIALS AND EQUIPMENT ON PREMISES AS DIRECTED, NEATLY

PILE OR STORE THEM AND PROTECT FROM DAMAGE. DO NOT REUSE MATERIALS AND

EQUIPMENT UNLESS SPECIFICALLY INDICATED ON PLANS OR SPECIFIED. REMOVE FROM

PREMISES AND DISPOSE OF ALL MATERIALS CONSIDERED BY THE OWNER/ARCHITECT TO BE

SCRAP.

D. PERFORM CUTTING AND PATCHING OF THE CONSTRUCTION WORK WHICH MAY BE

REQUIRED FOR THE PROPER DEMOLITION OF THE ELECTRICAL WORK. PATCHING SHALL BE

OF THE SAME MATERIAL, THICKNESS, WORKMANSHIP AND FINISH AS EXISTING AND

ACCURATELY MATCH SURROUNDING WORK TO THE SATISFACTION OF THE OWNER.

CUTTING OF STRUCTURAL MEMBERS SHALL NOT BE DONE WITHOUT FIRST OBTAINING

APPROVAL FROM THE OWNER AND/OR STRUCTURAL ENGINEER OF RECORD.

1) PATCHING OF OPENINGS IN RATED PARTITIONS, BARRIERS, FLOORS,

CEILINGS,ETC. SHALL BE EXECUTED USING UL AND NEPA FIRE STOP

MATERIAL EQUAL TO THE FIRE RATINGS OF THE PENETRATED SURFACE.

2) WHERE MATERIALS AND EQUIPMENT HAVE BEEN REMOVED AND NOT

REPLACED THE EXPOSED SURFACE SHALL BE PAINTED TO MATCH

SURROUNDING SURFACE COLOR.

E. AS INDICATED, DISCONNECT AND REMOVE EXISTING ELECTRICAL EQUIPMENT, DISCONNECT

SWITCHES, RECEPTACLES, MOUNTING HARDWARE AND ASSOCIATED RACEWAYS,

CONDUCTORS AND OUTLET BOXES. WHERE OUTLET BOXES ARE FLUSH AND CONDUITS ARE

CONCEALED IN EXISTING REMAINING WALLS, REMOVE WIRING AND ABANDON CONDUIT IN

PLACE.

F. EXCEPT AS NOTED OTHERWISE DISCONNECT AND REMOVE EXISTING FIRE ALARM SYSTEM

EQUIPMENT, DEVICES, MOUNTING HARDWARE AND ASSOCIATED RACEWAYS, CONDUCTORS

AND OUTLET BOXES. WHERE OUTLET BOXES ARE FLUSH AND CONDUITS ARE CONCEALED

IN EXISTING REMAINING WALLS, REMOVE WIRING AND ABANDON CONDUITS IN PLACE.

G. WHERE INDICATED BY THE DRAWINGS REMOVE EXISTING ELECTRICAL DISTRIBUTION

EQUIPMENT INCLUDING SWITCHBOARDS, DISTRIBUTION BOARDS, PANELBOARDS, MOTOR

CONTROL CENTERS, TRANSFORMERS, LOAD CENTERS, ETC. MODIFICATIONS TO THE MAIN

SWITCHBOARD SHALL NOT TAKE PLACE UNTIL THE SERVING UTILITY POWER COMPANY IS

NOTIFIED. COMPLY WITH ALL POWER OUTAGE RESTRICTIONS INDICATED ELSEWHERE IN THE

CONTRACT DOCUMENTS.

H. EXCEPT AS NOTED OTHERWISE REMOVE EXISTING TIME SWITCHES CONTACTORS,

RELAYS AND ASSOCIATED CONDUITS AND CONDUCTORS CONTROLLING HVAC SYSTEMS.

I. WHERE EXISTING WALL AND CEILINGS ARE TO REMAIN, PROVIDE BLANK COVER PLATES FOR

OUTLETS WHERE EQUIPMENT OR DEVICES ARE REMOVED UNDER THIS CONTRACT. PRIME

BLANK PLATES AND PAINT TO MATCH SURROUNDING AREA.

J. REFER TO THE DRAWINGS FOR ALL EQUIPMENT TO BE RELOCATED AND REUSED.

K. THE CONTRACTOR SHALL FIELD VERIFY EXISTING EQUIPMENT, DEVICES, AND/OR CIRCUITS

THAT ARE REMAINING. CIRCUITS SHALL BE RECONNECTED TO NEW OR EXISTING POWER

DISTRIBUTION EQUIPMENT AND FUNCTION IN THE MANNER THEY WERE ORIGINALLY

DESIGNED. PROVIDE ADDITIONAL EQUIPMENT, DEVICES, OUTLET BOXES, CONDUIT, WIRING,

ETC. AS REQUIRED TO RESTORE CONTINUITY TO THESE CIRCUITS.

L. WHERE FIXTURES, EQUIPMENT, DEVICES, ETC. ARE SPECIFIED BY THE CONTRACT

DOCUMENTS FOR REMOVAL, THE CONTRACTOR SHALL REMOVE ALL CIRCUIT

CONDUCTORS/CABLING BACK TO THE NEAREST REMAINING JUNCTION BOX AND/OR POINT

OF TERMINATION.

M. PROVIDE ADDITIONAL CONDUIT, CONDUCTORS, CABLING, OUTLET BOXES, ETC. AS

REQUIRED FOR THE RELOCATION OF ELECTRICAL APPARATUS.

N. RELOCATION AND/OR REMOVAL OF EXISTING EQUIPMENT, DEVICES, OUTLET BOXES,

CONDUIT, WIRING, ETC. MAY AFFECT THE OPERATION OF EXISTING, REMAINING ELECTRICAL

EQUIPMENT /DEVICES. THE CONTRACTOR SHALL PROVIDE ADDITIONAL MATERIALS AS

REQUIRED TO MAINTAIN AND/OR RESTORE CONTINUITY OF SERVICE TO EXISTING,

REMAINING ELECTRICAL/DEVICES.

O. PROVIDE ALL NECESSARY DEMOLITION TO REMOVE EXISTING UNUSED RACEWAYS,

CONDUCTORS, CABLING, OUTLET BOXES, RECEPTACLES, SWITCHES, EQUIPMENT, ETC.

P. WHERE IT IS NOT FEASIBLE TO REMOVE UNUSED FLUSH MOUNTED OUTLET BOXES AND

CONCEALED RACEWAYS IN EXISTING, REMAINING WALLS AND/OR CEILINGS REMOVE ALL

WIRING AND PROVIDE BLANK COVER PLATES OVER OUTLET BOXES.

Q. ALL CONDUITS RISING FROM BELOW GRADE TO AREAS WHERE PARTITIONS, WALLS, AND/OR

OTHER CONSTRUCTION ENTITIES ARE INDICATED AS BEING REMOVED SHALL BE CUT TO

BELOW FINISH FLOOR, CAPPED AND ABANDONED. PROVIDE PATCHING AS REQUIRED. SEAL

IN A MANNER ACCEPTABLE TO THE OWNER.

R. COVER UNUSED AND/OR ABANDONED OUTLETS WITH BLANK COVER PLATES.

S. SEAL ALL ABANDONED FLOOR PENETRATIONS IN A MANNER ACCEPTABLE TO THE OWNER.

T. DISCONNECT ABANDONED CIRCUITS AT EXISTING PANELBOARDS AND REMOVE WIRE TO

LAST REMAINING DEVICE. LABEL ALL ABANDONED CIRCUIT BREAKERS "SPARE".

U. PROVIDE WEATHERPROOF CAPS ON ABANDONED CONDUITS PENETRATING THE ROOF.

REPAIR ROOFING DAMAGED BY REMOVAL OF EXISTING ELECTRICAL EQUIPMENT.

V. PROVIDE NEW TYPEWRITTEN DIRECTORIES FOR RE-USED PANELBOARDS THAT ARE ALTERED

AS PART OF THE DEMOLITION.

W. EXISTING CIRCUITS THAT ARE REMOVED AND NOT RE-USED SHALL BE IDENTIFIED ON THE

PANEL DIRECTORIES AS "SPARE".

X. THE CONTRACTOR SHALL PROVIDE CIRCUIT NUMBERS AND LOADS FOR ALL EXISTING

REMAINING EQUIPMENT. PRIOR TO RECONNECTION, REASSIGN CIRCUITS AS REQUIRED TO

BALANCE LOADS EVENLY ACROSS PHASES WHEN RECONNECTED. PROVIDE COMPLETE "AS-

BUILTS" DRAWINGS.

1.

2.

3.

4.

5.

6.

7.

DEMOLITION NOTES

LOW VOLTAGE NOTES

1.

2.

3.

ELECTRICAL CONTRACTOR TO PROVIDE 120V TO POWER SUPPLIES FOR NURSE CALL, FIRE ALARM, SECURITY AND AV SYSTEMS AS REQUIRED BY TECHNOLOGY DRAWINGS.

ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT FOR VOICE/DATA, NURSE CALL, FIRE ALARM, SECURITY

AND AV SYSTEMS AS REQUIRED BY TECHNOLOGY DRAWINGS.

NURSE CALL AND FIRE ALARM DRAWINGS SUBMITTED UNDER DEFERRED APPROVAL.

PRECONSTRUCTION NOTES

1.

2.

CONTRACTOR SHALL PROVIDE A 30 DAY LOAD MEASUREMENT OF EQUIPMENT INDICATED AND PROVIDE THE RESULTS TO THE ENGINEER OF RECORD (EEOR) TO VERIFY THE EQUIPMENT HAS CAPACITY TO SUPPORT ADDITIONAL LOAD. LOAD MEASUREMENTS SHALL BE SUBMITTED PRIOR TO OR ALONG WITH EQUIPMENT SUBMITTALS. EQUIPMENT SUBMITTALS WITHOUT LOAD MEASUREMENTS SHALL BE RETURNED

AND NOT REVIEWED.

CONTRACTOR SHALL PROVIDE A SUBMITTAL INDICATING CIRCUIT TRACING OF ALL EXISITNG CIRCUITS THAT ARE BEING REUSED. ALONG WITH OR PRIOR TO EQUIPMENT SUBMITTALS. EQUIPMENT SUBMITTALS

SUBMITTED WITHOUT CIRCUIT TRACING SHALL BE RETURNED AND NOT REVIEWED.

Revisions: Date:

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

No. E17012

PA

T R

I CK WA LDENFELS

09/30/2021

E L E C T R I C A L

LIGHT FIXTURE SCHEDULE

TYPE FIXTURE DESCRIPTION MANUFACTURER & MODEL TOTAL

V-A

LAMP

TYPE LUMENS COLOR

TEMP CRI VOLTAGE MTG CEILING TYPE REMARKS

L1 6" LED SEALED, RECESSED DOWNLIGHT

MRI RATED FIXUTRE.

KENALL

MRIDL6-PAFW-23L-35K9-RIMRI6-

24V-DIM1

23 LED 1504 3500 90 24 R - NOTES : 1, 2

L2 6" LED SEALED, RECESSED DOWNLIGHT

WITH FLUSH LENS TRIM.

LITHONIA LIGHTING

LDN6-35/30-LO6-WR-MVOLT 35 LED 3139 3500 90 MVOLT R - NOTES : 1, 2

L3 2 X 4 LED FIXTURE. LITHONIA LIGHTING

2BLT4-30L-ADSM-MVOLT-LP935 24 LED 3000 3500 90 MVOLT R - NOTES : 1, 2

NOTES: MOUNTING ABBREVIATIONS:

P = PENDANT

R = RECESSED

S = SURFACE

U = UNDERCABINET

1. COLOR/FINISH AS SELECTED BY ARCHITECT.

GENERAL

NOTES:

1. LIGHTING FIXTURE TYPE SHALL BE TYPE AS INDICATED ON FIXTURE SCHEDULE

AND SHALL BE U.L APPROVED.

2.

IT IS THE CONTRACTORS RESPONSIBILITY TO DETERMINE ACTUAL CEILING

CONSTRUCTION TYPE AS DEFINED ON THE ARCHITECTURAL DRAWINGS AND

FURNISH ALL LIGHTING FIXTURES WITH THE CORRECT MOUNTING DEVICES AND

PROPER OPERATING VOLTAGE.

3. LAMPS SHALL BE TYPE AS INDICATED ON DRAWINGS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

E-003

SCHEDULES

TRIPLE C - THE A/E GROUP

4401 ATLANTIC AVENUE, SUITE 200

LONG BEACH, CA 90807

562.452.7175

MAT PERKINS

REPLACE LINEAR ACCELERATOR

11301 Wilshire Blvd, West Los Angeles, CA 90073

691-CSI-121

07/29/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

TOTAL PANEL = 20,028 VA @ 208V, 3Ø = 56 AMPS

LCL = 0 VOLT-AMPS

TOTAL ØC = 3,620 VOLT-AMPS

TOTAL ØB = 7,448 VOLT-AMPS 1.

TOTAL ØA = 8,960 VOLT-AMPS * "L" DENOTES LONG CONTINUOUS LOAD

NOTES:

SPACE 41 - - * 42 SPACE

SPACE 39 - * - 40 SPACE

SPACE 37 * - - 38 SPACE

SPACE 35 - - * 36 SPACE

SPACE 33 - * - 34 SPACE

SPACE 31 * - - 32 SPACE

SPACE 29 - - * 30 SPACE

SPARE 27 20/1 - * - 28 SPACE

SPARE 25 20/1 * - - 26 SPACE

SPARE 23 20/1 - - * 24 SPACE

RM.0687 REC. 3 540 21 20/1 - * - 20/1 22 SPARE

RM.0689 REC. 4 720 19 20/1 * - - 20/1 20 SPARE

RM.0689 S-4 2 17 20/1 - - * 20/1 18 SPARE

RM.0689 S-3 2 1,000 15 20/1 - * - 20/1 16 540 3 TREATMENT REC.

RM.0689 S-2 2 1,000 13 20/1 * - - 14 1,000 3 DATA ROOM-4

RM.0689 PRINT-1 1 500 11 20/1 - - * - 12 -

RM.0689 S-1 2 1,000 9 20/1 - * - 20/2 10 1,248 1 DATA ROOM-3

- 1,872 7 - * - - - 8 1,248 -

OU-2 1,872 5 25/2 - - * 20/2 6 1,248 1 DATA ROOM-2

- 1,872 3 - - * - - 4 1,248 -

OU-1 1,872 1 25/2 * - - 20/2 2 1,248 1 DATA ROOM-1

LOADS NOTE LTG REC MISC A B C CKT POLE A B C POLE CKT A B C LTG REC MISC NOTE LOADS

SEE * OU... VOLT... BKR/ BKR/ VOLT... OU... * SEE

MOUNTING : FLU... MAIN BREAKER : 100A/3P

FLOOR : FIRST FLOOR BUS AMPS : 100A MINIMUM BUS BRACING : 10KIAC

LOCATION : RM. 0689 VOLTAGE/PHASE : 120/208V, 3Ø, 4W FED FROM : XMFR "TL"

PANEL: (N)LIN2

TOTAL PANEL = 98,532 VA @ 480V, 3Ø = 119 AMPS

LCL = 0 VOLT-AMPS

TOTAL ØC = 32,844 VOLT-AMPS

TOTAL ØB = 32,844 VOLT-AMPS

TOTAL ØA = 32,844 VOLT-AMPS * "L" DENOTES LONG CONTINUOUS LOAD

NOTES:

SPACE 41 - - * - 42 10,000 -

SPACE 39 - * - - 40 10,000 -

SPACE 37 * - - 50/3 38 10,000 TRANSFORMER "TL"

SPACE 35 - - * 36 SPACE

SPACE 33 - * - 34 SPACE

SPACE 31 * - - 32 SPACE

SPACE 29 - - * 30 SPACE

SPACE 27 - * - 28 SPACE

SPACE 25 * - - 26 SPACE

SPACE 23 - - * 24 SPACE

SPACE 21 - * - 22 SPACE

SPACE 19 * - - 20 SPACE

SPACE 17 - - * 20/1 18 SPARE

SPACE 15 - * - 20/1 16 SPARE

SPACE 13 * - - 20/1 14 SPARE

SPARE 11 20/1 - - * - 12 3,878 -

SPARE 9 20/1 - * - - 10 3,878 -

SPARE 7 20/1 * - - 20/3 8 3,878 AC-1

- 16,666 5 - - - * - 6 2,300 -

- 16,666 3 - - * - - 4 2,300 -

PDU 16,666 1 70/3 * - - 20/3 2 2,300 FCU-1

LOADS NOTE LTG REC MISC A B C CKT POLE A B C POLE CKT A B C LTG REC MISC NOTE LOADS

SEE * OU... VOLT... BKR/ BKR/ VOLT-A... OU... * SEE

MOUNTING : FLUSH MAIN BREAKER : 200/3P

FLOOR : BASEMENT BUS AMPS : 225A MINIMUM BUS BRACING : 22KIAC

LOCATION : BASEMENT VOLTAGE/PHASE : 277/480V, 3Ø, 4W FED FROM : US #3

PANEL: (N)LIN1

1 AIC RATING OF THE PANEL IS PRELIMINARY. CONTRACTOR SHALL UPDATED THE AIC RATING ONCE THE SHORT CIRCUIT, OVERCURRENT COORDINATION AND ARC FLASH STUDY IS COMPLETED. REFER TO SINGLE LINE DIAGRAM ON SHEET E-601 FOR MORE DETAILS.

1 1

1 AIC RATING OF THE PANEL IS PRELIMINARY. CONTRACTOR SHALL UPDATED THE AIC RATING ONCE THE SHORT CIRCUIT, OVERCURRENT COORDINATION AND ARC FLASH STUDY IS COMPLETED. REFER TO SINGLE LINE DIAGRAM ON SHEET E-601 FOR MORE DETAILS.

Revisions: Date:

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

No. E17012

PA

T R

I CK WA LDENFELS

09/30/2021

E L E C T R I C A L

'(E) LA''(E) BXR2-3'

(E)(E)(E)(E)

(E)

(E)

(ER)

(ER)

(ER)

(E)

(E)

(E)

(E)

(E)

1 (TYPICAL)

2(TYPICAL)

(ER)

(ER)

(ER)

(ER)

(ER)

B500 KEY PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ED100-0

ELECTRICAL DEMO PLAN - GROUND

FLOOR

TRIPLE C - THE A/E GROUP

4401 ATLANTIC AVENUE, SUITE 200

LONG BEACH, CA 90807

562.452.7175

MAT PERKINS

REPLACE LINEAR ACCELERATOR

11301 Wilshire Blvd, West Los Angeles, CA 90073

691-CSI-121

07/29/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

1 EXISTING DEVICE TO REMAIN.

REFER TO DEMOLITION NOTED SHEET E-002 FOR ADDITIONAL

REQUIREMENTS.

ALL REMAINING ABOVE CEILING CONDUITS SERVING AREAS

OUTSIDE OF THE PROJECT AREA THAT OBSTRUCT THE

INSTALLATION OF THE NEW CEILING AND HVAC ELEMENTS ARE TO

BE INTERCEPTED, RE-ROUTED AND RECONNECTED. CONTRACTOR

TO CIRCUIT TRACE AND DOCUMENT THE FOLLOWING TO

COORDINATE WITH OWNER TO MINIMIZE DISRUPTIONS TO THE

FACILITY.

ALL DEVICES OUTSIDE THE PROJECT AREA TO REMAIN IN

SERVICE.

PROVIDE SUBMITTAL INDICATING CIRCUIT TRACING ALONG WITH

OR PRIOR TO EQUIPMENT SUBMITTALS. EQUIPMENT SUBMITTALS

SUBMITTED WITHOUT CIRCUIT TRACING SHALL BE RETURNED AND

NOT REVIEWED.

1.

2.

3.

4.

RELOCATE EXISTING PANEL TO NEW LOCATION SHOWN

ON PLAN. EXTEND EXISTING CONDUIT/FEEDERS TO NEW

LOCATION.

2 DEMOLISH EXISTING DEVICE BACK TO LAST EXISTING

JUNCTION BOX OUTSIDE OF THE SCOPE OF WORK.

COORDINATE EXTENT OF DEMOLITION WITH ARCHITECTURAL

DRAWINGS.

DEMOLISH EXISTING FEEDERS SERVING THE EXISTING

LINER ACCELERATOR BACK TO THE SOURCE.

DEMOLISH EXISTING POWER DISTRIBUTION UNIT (PDU),

AND FEEDERS BACK TO THE SOURCE.

Revisions: Date:

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

No. E17012

PA

T R

I CK WA LDENFELS

09/30/2021

E L E C T R I C A L

1 (TYPICAL)

1 (TYPICAL)

1 (TYPICAL)

2(TYPICAL)

2(TYPICAL)

GLB-20

GLAE-3

GLB-22

B500 KEY PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ED100-1

ELECTRICAL DEMO RCP PLAN -

GROUND FLOOR

TRIPLE C - THE A/E GROUP

4401 ATLANTIC AVENUE, SUITE 200

LONG BEACH, CA 90807

562.452.7175

MAT PERKINS

REPLACE LINEAR ACCELERATOR

11301 Wilshire Blvd, West Los Angeles, CA 90073

691-CSI-121

07/29/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

EXISTING LIGHTING FIXTURE TO BE DISCONNECTED AND

REMOVED. EXISTING LIGHTING CIRCUIT TO REMAIN TO BE

REUSED.

EXISTING LIGHTING CONTROLS TO BE DISCONNECTED

AND REMOVED.

REFER TO DEMOLITION NOTED SHEET E-002 FOR ADDITIONAL

REQUIREMENTS.

ALL REMAINING ABOVE CEILING CONDUITS SERVING AREAS

OUTSIDE OF THE PROJECT AREA THAT OBSTRUCT THE

INSTALLATION OF THE NEW CEILING AND HVAC ELEMENTS ARE TO

BE INTERCEPTED, RE-ROUTED AND RECONNECTED. CONTRACTOR

TO CIRCUIT TRACE AND DOCUMENT THE FIXTURE CIRCUITS TO

COORDINATE WITH OWNER TO MINIMIZE DISRUPTIONS TO THE

FACILITY.

PROVIDE SUBMITTAL INDICATING CIRCUIT TRACING ALONG WITH

OR PRIOR TO EQUIPMENT SUBMITTALS. EQUIPMENT SUBMITTALS

SUBMITTED WITHOUT CIRCUIT TRACING SHALL BE RETURNED AND

NOT REVIEWED.

1.

2.

3.

3 INTERCEPT EXISTING CONDUIT AND EXISTING CIRCUIT.

REUSE AND EXTEND EXISTING CIRCUIT TO NEW LOCATION.

REFER TO RENOVATION PLANS FOR NEW LOCATION.

CONTRACTOR TO CIRCUIT TRACE EXISTING CIRCUIT AND

FIELD VERIFY EXISTING CONDUCTOR SIZE AND PROVIDE

SHOP DRAWINGS AND SUBMIT TO EEOR FOR REVIEW

PRIOR TO START OF WORK.

PROVIDE SUBMITTAL INDICATING CIRCUIT TRACING ALONG

WITH OR PRIOR TO EQUIPMENT SUBMITTALS. EQUIPMENT

SUBMITTALS SUBMITTED WITHOUT CIRCUIT TRACING

SHALL BE RETURNED AND NOT REVIEWED.

Revisions: Date:

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

No. E17012

PA

T R

I CK WA LDENFELS

09/30/2021

E L E C T R I C A L

(E)(E)(E)(E)

(E)

(E)

'BXR2-3'

'LA'

(E)

(E)

(E)

(E)

(E)

PDU PULL BOX

PULL BOX

PULL BOX

EMERGENCY OFF BUTTON

MAIN POWER DISCONNECT "MB"

LIN2-1,3

LIN2-5,7

LIN1-2,4,6

LIN2-10,12

LIN2-6,8

LIN2-2,4

OU-1

OU-2

LIN2-14

FCU-1

5 6

'LIN2' 7

LIN2-9

9 9

LIN2-11

LIN2-13

13 13

LIN2-15

LIN2-17

TRENCH

ES

RL

ES

DS

RL

181716

ES

RL

ES

+48"

LIN2-16

191919

19 LIN2-19

+48"

LIN2-21

POWER CONDITIONER 21

LIN1-8,10,1222 14

AC-1

B500 KEY PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

E-100-0

ELECTRICAL RENOVATION PLAN -

GROUND FLOOR

TRIPLE C - THE A/E GROUP

4401 ATLANTIC AVENUE, SUITE 200

LONG BEACH, CA 90807

562.452.7175

MAT PERKINS

REPLACE LINEAR ACCELERATOR

11301 Wilshire Blvd, West Los Angeles, CA 90073

691-CSI-121

07/29/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

1 RELOCATE EXISTING PANEL TO NEW LOCATION SHOWN ON

PLAN. EXTEND EXISTING CONDUIT/FEEDERS AND BRANCH

CIRCUITS TO NEW LOCATION. COORDINATED SHUTDOWNS

WITH THE OWNER/USER.

ALL CONDUITS PENETRATING CONCRETE FLOORS OR WALLS

SHALL BE COORDINATED WITH SEOR PRIOR TO COMMENCEMENT

OF WORK.

ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS

OF ALL CONNECTION POINTS WITH EQUIPMENT INSTALLER PRIOR

TO ROUGH-IN.

ELECTRICAL CONTRACTOR SHALL REFER TO MECHANICAL AND

ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND

CHARACTERISTICS OF ALL MECHANICAL EQUIPMENT.

CONTRACTOR TO PROVIDE DETAILED METHOD OF PROCEDURE

(MOP) WITH CONTINGENCY PLAN FOR THE REVIEW BY OWNER,

ARCHITECT AND EEOR PRIOR TO POWER SHUT DOWN.

VERIFY ALL VERIFY ALL REQUIREMENTS ASSOCIATED WITH THE

LINEAR ACCELERATOR EQUIPMENT WITH THE LINEAR

ACCELERATOR VENDOR PRIOR TO ROUGH-IN.

2 PER VENDOR DRAWING SHEET E101 PDU PULL BOX

(FLOOR). PROVIDE 2'-0" X 1'-6" X 1'-0" WITH COVER PLATE.

LAST 6" OPEN TO REMAIN OPEN. COVER RATED FOR WEIGHT

OF PDU.

3 PER VENDOR DRAWING SHEET E101 PROVIDE CONDUIT

FLOOR PULL BOX 1'-0" X 8" X 8".

4 PER VENDOR DRAWING SHEET E101 PROVIDE 6" X 6" X 6"

PATIENT TABLE PULL BOX WITH DIVIDER.

5 REFER TO SINGLE LINE DIAGRAM FOR REQUIREMENTS.

6 PROVIDE STRUCTURAL SUPPORT PER SEISMIC ANCHORAGE

SPECIFICATION REQUIREMENTS.

7 PER VENDOR DRAWING SHEET E101 PROVIDE NEMA L6-20

RECEPTACLE.

8 PROVIDE 208V, 30AS, 25AF,2P DISCONNECT SWITCH IN THE

INTERSTITIAL SPACE. PROVIDE UNISTRUT MOUNTING FOR

DISCONNECT SWITCH AS REQUIRED. COORDINATE EXACT

LOCATION IN FIELD.

1.

2.

3.

4.

5.

9 PROVIDE 480V, 30AS, 20AF,3P DISCONNECT SWITCH IN THE

INTERSTITIAL SPACE. PROVIDE UNISTRUT MOUNTING FOR

DISCONNECT SWITCH AS REQUIRED. COORDINATE EXACT

LOCATION IN FIELD.

10 PER VENDOR DRAWING SHEET E101 APOLLO LASER WALL

POWER SWITCH PROVIDED BY VENDOR.

11 PER VENDOR DRAWING SHEET E101 PROVIDE EMERGENCY

OFF BUTTON.

12 PER VENDOR DRAWING SHEET E101 PROVIDE EMERGENCY

STOP BUTTON.

13 PER VENDOR DRAWING SHEET E101 PROVIDE DOOR

INTERLOCK SWITCH.

14 PER VENDOR DRAWING SHEET E101 PROVIDE RADIATION

WARNING LIGHT.

15 PER VENDOR DRAWING SHEET E101 PROVIDE 4#4 + 1#8 GND.

IN 4" CONDUIT.

16 PER VENDOR DRAWING SHEET E101 PROVIDE 2#12 IN 1"C

FROM EMERGENCY STOP SWITCHES TO PDU.

17 PER VENDOR DRAWING SHEET E101 PROVIDE 2#12 IN 1"C

FROM RADIATION WARNING LIGHTS TO PDU.

18 PER VENDOR DRAWING SHEET E101 PROVIDE 2#12 IN 1"

PROVIDE 1"C FROM DOOR INTERLOCK SWITCH TO PDU.

19 PER VENDOR DRAWING SHEET E101 PROVIDE (4) 4" CONDUIT.

20 PER VENDOR DRAWING SHEET E101 PROVIDE 4" PHYSICS

PORT CONDUIT.

Revisions: Date:

21 PER VENDOR DRAWING PROVIDE NEW POWER CONDITIONER.

COORDINATE EXACT LOCATION IN FIELD.

22 PROVIDE 480V, 30AS, 20AF,3P DISCONNECT SWITCH IN THE

PROVIDE UNISTRUT MOUNTING FOR DISCONNECT SWITCH AS

REQUIRED. COORDINATE EXACT LOCATION IN FIELD.

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

No. E17012

PA

T R

I CK WA LDENFELS

09/30/2021

E L E C T R I C A L

L1

L1

L1

L1

L1

L1

L1

L1 L1

GLAE-3

L1 L1

L1

L1L1

L1

L3

L2

L2

L3

L2 L2

L2 L2

GLB-20

GLB-22

B500 KEY PLAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

E-100-1

ELECTRICAL RENOVATION RCP

PLAN - GROUND FLOOR

TRIPLE C - THE A/E GROUP

4401 ATLANTIC AVENUE, SUITE 200

LONG BEACH, CA 90807

562.452.7175

MAT PERKINS

REPLACE LINEAR ACCELERATOR

11301 Wilshire Blvd, West Los Angeles, CA 90073

691-CSI-121

07/29/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

1 INSTALL AND CONNECT NEW FIXTURE TO EXISTING

LIGHTING CIRCUIT AND NEW LIGHTING CONTROLS. MATCH

EXISTING CONDUCTOR TYPE AND SIZE WHEN MODIFYING

AND EXTENDING EXISTING CIRCUITS.

ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS

OF ALL CONNECTION POINTS WITH EQUIPMENT INSTALLER PRIOR

TO ROUGH-IN.

ALL DEVICES OUTSIDE THE PROJECT AREA TO REMAIN IN SERVICE.

1.

2.

Revisions: Date:

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

No. E17012

PA

T R

I CK WA LDENFELS

09/30/2021

E L E C T R I C A L

GROUND FLOOR

GROUND FLOOR

INTERSTITIAL

(E) DIST. SECTION BXR-2

2500A, 480/277V, 3PH, 4W

PANEL

"BXR2-3"

(E)

(E) 150A 3P

BASEMENT FLOOR

(E) "T1"

15KVA

480-120/208,3PH,4W

x.x%IMP

PANEL

"LA"

(E)

PANEL

"LIN2"

(N)

PANEL

"LIN1"

(N)

(N) "TL"

30KVA

480-120/208,3PH,4W

TO (E) T3

(E)

1500KVA

4.16KV-

480/277V,3PH,4W

6.7%IMP

(E) 2500A 3P

(E) UNIT SUBSTATION #3 (E) DIST. SECTION 2500A, 480/277V, 3PH, 4W

(E)

600AS

600AT

3P

(E)

800AS

800AT

3P

(E)

600AS

600AT

3P

(E)

600AS

600AT

3P

(N)

200AS

200AT

3P

(N) 80A 3P

ENCLOSED CIRCUIT

BREAKER "MB"4

(N)30AS

20AF

3P

2"C.-4#3/0 & 1#6 GND

2"C.4#1+1#8 GND

FCU

8HP

8.3FLA

3/4"C.-3#12 & 1#10 GND.

1"C.-4#6 & 1#10 GND

(N)100AS

100AF

3P

OU

OU

(N)30AS

25AF

2P

(N)30AS

25AF

2P

3/4"C.-3#12 & 1#12 GND.

(N) POWER

CONDITIONER

(N)30AS

20AF

3P

AC

10HP

14FLA

3/4"C.-3#12 & 1#10 GND.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

E-601

SINGLE LINE DIAGRAM

TRIPLE C - THE A/E GROUP

4401 ATLANTIC AVENUE, SUITE 200

LONG BEACH, CA 90807

562.452.7175

MAT PERKINS

REPLACE LINEAR ACCELERATOR

11301 Wilshire Blvd, West Los Angeles, CA 90073

691-CSI-121

07/29/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

ALL NEW FEEDER CONDUCTORS SHALL BE CONTINUOUS WITH NO

SPLICES.

ALL FEEDERS SHALL BE COPPER WITH 90° C. (THHN/THWN)

INSULATION.

NEW CIRCUIT BREAKERS SHALL BE TYPE TO MATCH EXISTING,

UON. PROVIDE ALL REQUIRED MOUNTING HARDWARE, LUGS AND

COVERPLATES FOR A COMPLETE INSTALLATION.

PROVIDE SCHNEIDER SURFACE WALL MOUNTED ENCLOSED

80A CIRCUIT BREAKER WITH 277V SHUNT TRIP AND BUILT-IN

EPO SWITCH ON NEMA 1 ENCLOSURE.

REFER TO SHEETS E-602 FOR ADDITIONAL REQUIREMENTS.4

CONTRACTOR SHALL PROVIDE A 30 DAY LOAD MEASUREMENT

OF EQUIPMENT INDICATED AND PROVIDE THE RESULTS TO

THE ENGINEER OF RECORD (EEOR) TO VERIFY THE

EQUIPMENT HAS CAPACITY TO SUPPORT ADDITIONAL LOAD.

LOAD MEASUREMENTS SHALL BE SUBMITTED PRIOR TO OR

ALONG WITH EQUIPMENT SUBMITTALS. EQUIPMENT

SUBMITTALS WITHOUT LOAD MEASUREMENTS SHALL BE

RETURNED AND NOT REVIEWED.

PROVIDE NEW CIRCUIT BREAKER INDICATED IN AVAILABLE

SPACE. TYPE AND RATING TO MATCH EXISTING. PROVIDE ALL

REQUIRED MOUNTING HARDWARE, LUGS AND COVERPLATES

FOR A COMPLETE INSTALLATION.

3/4"C.-1#6 GND. WIRE TO EXISTING GROUNDING SYSTEM.5

1"C.-4#4 & 1#6 GND.6

PER VENDOR DRAWING SHEET E101 PROVIDE 4#4 + 1#6

GND. IN 4" CONDUIT.

CONTRACTOR TO PROVIDE SHORT CIRCUIT, OVERCURRENT

PROTECTIVE DEVICE COORDINATION AND ARC FLASH ANALYSIS

FOR ALL NEW PANELS, SWITCHBOARDS AND SWITCHGEAR. STUDY

SHALL INCLUDE EXISTING SYSTEM TO THE EXTENT THAT THE FAULT

CURRENT, COORDINATION AND ARC FLASH PREPARED IN

COMPLIANCE WITH 2018 NFPA 70E FOR THE NEW PANELS CAN BE

CALCULATED. CONTRACTOR IS RESPONSIBLE FOR ALL DATA

COLLECTION REQUIRED TO COMPLETE THE ANALYSIS. REPORT OF

THE ANALYSIS SHALL BE PREPARED SUMMARIZING THE INPUT

DATA, SINGLE-LINE USED IN CALCULATION, AND RESULTS

INCLUDING ARC FLASH LABELS. REPORT SHALL BE STAMPED AND

SIGNED BY PROFESSIONAL ENGINEER UNDER WHOSE DIRECTION

THE STUDY WAS PERFORMED. CONTRACTOR TO INSTALL ARC

FLASH LABELS ON PANELS IN COMPLIANCE WITH 2018 NFPA 70E.

ELECTRICAL EQUIPMENT SUBMITTALS SHALL REFLECT RESULTS OF

SHORT CIRCUIT ANALYSIS. CONTRACTOR SHALL SET ALL

ADJUSTABLE CIRCUIT BREAKERS PER OVERCURRENT PROTECTIVE

DEVICE STUDY. MINIMAL INFORMATION INCLUDED ON ARC FLASH

LABELS INCLUDE:

1. NOMINAL SYSTEM VOLTAGE

2. ARC FLASH BOUNDARY

3. AT LEAST ONE OF THE FOLLOWING:

a.EITHER THE AVAILABLE INCIDENT ENERGY AND

THE CORRESPONDING WORKING DISTANCE, OR

THE ARC FLASH PPE CATEGORY FOR THE

EQUIPMENT, BUT NOT BOTH.

b.MINIMUM ARC RATING OF CLOTHING.

c.SITE-SPECIFIC LEVEL OF PPE.

ANALYSIS SHALL BE PREPARED PRIOR TO OR CONCURRENT WITH

ELECTRICAL SWITCHGEAR, SWITCHBOARDS AND PANEL

SUBMITTALS. EQUIPMENT SUBMITTALS WITHOUT ANALYSIS SHALL

BE REJECTED AND NOT REVIEWED.

EEOR CAN NOT BE RESPONSIBLE FOR ANALYSIS UNLESS

SEPARATELY AND SPECIFICALLY CONTRACTED TO DO SO.

1.

2.

3.

Revisions: Date:

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

No. E17012

PA

T R

I CK WA LDENFELS

09/30/2021

E L E C T R I C A L

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

E-602

LINAC EQUIPMENT DRAWINGS

TRIPLE C - THE A/E GROUP

4401 ATLANTIC AVENUE, SUITE 200

LONG BEACH, CA 90807

562.452.7175

MAT PERKINS

REPLACE LINEAR ACCELERATOR

11301 Wilshire Blvd, West Los Angeles, CA 90073

691-CSI-121

07/29/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

LINEAR ACCELERATOR EQUIPMENT INFORMATION BASED ON THE

LATEST PROVIDED BY ACCURAY. LATER REVISIONS PROVIDED BY

ACCURAY MAY REQUIRE CHANGES TO THE CONTRACT

DOCUMENTS. REFER TO ACCURAY DRAWINGS FOR ADDITIONAL

REQUIREMENTS.

ELECTRICAL CONTRACTOR TO PROVIDE COORDINATION DRAWINGS

INDICATING ALL REQUIREMENTS FOR ACCURAY LINEAR

ACCELERATOR EQUIPMENT AS INDICATED ON LATEST DRAWINGS

PROVIDED BY THE ACCURAY DESIGN TEAM, OWNER, AND VENDOR

TO REVIEW WITH NO EXCEPTION TAKEN PRIOR TO CONSTRUCTION.

ELECTRICAL CONTRACTOR TO COORDINATE SPECIFIC RACEWAY,

CONDUIT, DEVICE, JUNCTION BOX, ETC. , REQUIREMENTS WITH

SUPPLIER/VENDOR ( ACCURAY) FOR LINEAR ACCELERATOR

EQUIPMENT. RATING OF DEVICES, CONDUCTORS, AND CONDUIT TO

BE COORDINATED WITH VENDORS SITE SPECIFIC DOCUMENTS.

1.

2.

3.

Revisions: Date:

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

EFORP

DE

R E

T

SI

G E

R R E

E

NI

G

NE

LANOISS

C A L I F ORN

I AS

T

A T E O F

No. E17012

PA

T R

I CK WA LDENFELS

09/30/2021

E L E C T R I C A L

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of Construction and Facilities Management

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

E-603

LINAC EQUIPMENT DRAWINGS

TRIPLE C - THE A/E GROUP

4401 ATLANTIC AVENUE, SUITE 200

LONG BEACH, CA 90807

562.452.7175

MAT PERKINS

REPLACE LINEAR ACCELERATOR

11301 Wilshire Blvd, West Los Angeles, CA 90073

691-CSI-121

07/29/2020 Checker Author

100% CONSTRUCTION

DOCUMENTS

LINEAR ACCELERATOR EQUIPMENT INFORMATION BASED ON THE

LATEST PROVIDED BY ACCURAY. LATER REVISIONS PROVIDED BY

ACCURAY MAY REQUIRE CHANGES TO THE CONTRACT

DOCUMENTS. REFER TO ACCURAY DRAWINGS FOR ADDITIONAL

REQUIREMENTS.

ELECTRICAL CONTRACTOR TO PROVIDE COORDINATION DRAWINGS

INDICATING ALL REQUIREMENTS FOR ACCURAY LINEAR

ACCELERATOR EQUIPMENT AS INDICATED ON LATEST DRAWINGS

PROVIDED BY THE ACCURAY DESIGN TEAM, OWNER, AND VENDOR

TO REVIEW WITH NO EXCEPTION TAKEN PRIOR TO CONSTRUCTION.

ELECTRICAL CONTRACTOR TO COORDINATE SPECIFIC RACEWAY,

CONDUIT,…