(AC) Soil Report 2022b.pdf
PDF 222 KB Posted
- Solicitation number
- 5997283
About this file
This soil analysis report provides results of environmental testing conducted on samples from a site in Lebanon, Connecticut. The report identifies parameters tested including pH, ignitability, corrosivity, cyanide, sulfide, and polychlorinated biphenyls (PCBs). No exceedances of criteria were found. Testing was performed by Environmental Laboratories, Inc. in accordance with applicable EPA methods and quality control procedures were followed.
The related federal contract opportunity is for site development work at the Naval Submarine Base in New London, Connecticut. The solicitation seeks offers for construction and engineering services with an emphasis on developing the site. The Department of the Navy Naval Facilities Engineering Command is the contracting agency. No further details on submission deadlines, period of performance, or pricing are provided in the opportunity description.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Price Proposal Form.docx | DOCX document | |
| Amendment 0004.pdf | ||
| Wage Determ.docx | DOCX document | |
| (AA) Soil Report 2019.pdf | ||
| Amendment 0003.pdf | ||
| RFI Responses.pdf | ||
| (AI) Geotech Report 2023.pdf | ||
| (AD) Soil Summary.pdf | ||
| (AF) Utlility Map 2020.pdf | ||
| (AE) Soil Mgmt Plan.pdf | ||
| (AB) Soil Report 2022a.pdf | ||
| (AG) Utility Map 2021.pdf | ||
| (AH) Geotech Report 2021.pdf | ||
| (A) MACC RFP NPT NLON Rev 1.pdf | ||
| Amendment 0002.pdf | ||
| Site Visit Log.pdf | ||
| Amendment 0001.pdf | ||
| (H) General Requirements.pdf | ||
| (N) Building Contractors Guide to Taxes.pdf | ||
| (A) MACC RFP NPT NLON.docx | DOCX document | |
| (E) Site Approval.pdf | ||
| (L) ECMS.pdf | ||
| (O) 2016-R-0149.pdf | ||
| (G) Price Proposal Form.doc | DOC document | |
| (M) 52.204-24.pdf | ||
| (I) Base Map.pdf | ||
| (P) CERT-141.pdf | ||
| (C) Drawings.pdf | ||
| (B) Specifications.pdf | ||
| (D) NEPA.pdf | ||
| (K) RFI Form.pdf | ||
| (J) Map to B135.pdf | ||
| (F) DB Wages 16 JUN 2023.docx | DOCX document |
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sample Information Custody Information Matrix:
Location Code:
Rush Request:
P.O.#:
Collected by:
Received by:
Analyzed by:
SOIL
KROPP
24 Hour 21 I 105
01/27/22
CP
see "By" below
GK
Laboratory Data
PS-1
Phoenix ID: CK24253
01/27/22 9:40
12:59
Parameter Result
RL/
PQL Units Date/Time By Reference
FOR: Attn: Ms. Sally Wiese-Kropp Kropp Env. Contractors P.O. Box 258 Lebanon, CT 06249
Analysis Report January 28, 2022
Date Time
SDG ID: GCK24253
Client ID:
Project ID:
Dilution
587 East Middle Turnpike, P.O.Box 370, Manchester, CT 06045 Tel. (860) 645-1102 Fax (860) 645-0823
Environmental Laboratories, Inc.
81Percent Solid 01/27/22 Q SW846-%Solid% NegativeCorrosivity 01/28/22 MM SW846-CorrPos/Neg 1
>200Flash Point 200 01/28/22 BJA SW1010BDegree F 1 PassedIgnitability 140 01/28/22 BJA SW846-Ignitdegree F 1
5.82pH at 25C - Soil 1.00 01/28/22 00:00 MM SW846 9045DpH Units 1 < 6Reactivity Cyanide 6 01/28/22 DK SW846 7.3.3.1/90mg/Kg 1 < 20Reactivity Sulfide 20 01/28/22 DK/GD SW846 CH7mg/Kg 1
NegativeReactivity 01/28/22 DK/GD SW846-ReactPos/Neg 1
CompletedSoil Extraction for PCB 01/27/22 O/L SW3545A
Polychlorinated Biphenyls NDPCB-1016 410 01/28/22 SC SW8082Aug/Kg 10 NDPCB-1221 410 01/28/22 SC SW8082Aug/Kg 10 NDPCB-1232 410 01/28/22 SC SW8082Aug/Kg 10 NDPCB-1242 410 01/28/22 SC SW8082Aug/Kg 10 NDPCB-1248 410 01/28/22 SC SW8082Aug/Kg 10 NDPCB-1254 410 01/28/22 SC SW8082Aug/Kg 10 NDPCB-1260 410 01/28/22 SC SW8082Aug/Kg 10 NDPCB-1262 410 01/28/22 SC SW8082Aug/Kg 10 NDPCB-1268 410 01/28/22 SC SW8082Aug/Kg 10
QA/QC Surrogates
88% DCBP 01/28/22 SC 30 - 150 %% 10
84% DCBP (Confirmation) 01/28/22 SC 30 - 150 %% 10
79% TCMX 01/28/22 SC 30 - 150 %% 10
78% TCMX (Confirmation) 01/28/22 SC 30 - 150 %% 10
Page 1 of 2Ver 1
PS-1
Phoenix I.D.: CK24253
Client ID:
Project ID:
Parameter Result
RL/
PQL Units Date/Time ByDilution Reference
Comments:
Corrosivity is based solely on the pH analysis performed above.
Ignitability is based solely on the results of the closed cup flashpoint analysis performed above. Passed is >140 degree F.
The regulatory hold time for pH is immediately. This pH was performed in the laboratory and may be considered outside of hold-time.
The reactivity, reported above, is based only on the EPA Interim Guidance for Reactive Cyanide. This method is no longer listed in the current version of SW-846.
The reactivity, reported above, is based only on the EPA Interim Guidance for Reactive Sulfide. This method is no longer listed in the current version of SW-846.
All soils, solids and sludges are reported on a dry weight basis unless otherwise noted in the sample comments.
Phyllis Shiller, Laboratory Director January 28, 2022
If you are the client above and have any questions concerning this testing, please do not hesitate to contact Phoenix Client Services at ext.200.
The contents of this report cannot be discussed with anyone other than the client listed above without their written consent.
Official Report Release To Follow
RL/PQL=Reporting/Practical Quantitation Level ND=Not Detected BRL=Below Reporting Level QA/QC Surrogates: Surrogates are compounds (preceeded with a %) added by the lab to determine analysis efficiency. Surrogate results(%) listed in the report are not "detected" compounds.
Page 2 of 2Ver 1
Sample Criteria Exceedances ReportFriday, January 28, 2022 Page 1 of 1
Acode Phoenix Analyte CriteriaResult RLSampNo Analysis
UnitsCriteria
GCK24253 - KROPPCriteria: CT: GAM, RC
RL
Criteria
State: CT
#Type!*** No Data to Display ***
Phoenix Laboratories does not assume responsibility for the data contained in this exceedance report. It is provided as an additional tool to identify requested criteria exceedences. All efforts are made to ensure the accuracy of the data (obtained from appropriate agencies). A lack of exceedence information does not necessarily suggest conformance to the criteria. It is ultimately the site professional's responsibility to determine appropriate compliance.
| Analytical Report |
| Sample Criteria Exceedances Report |
| COC-GCK24253 |
File details come from the government source that posted it. Updated .