5-PRIVATE WELL SAMPLING LETTER - JULY 2023 NEWTON.pdf

PDF 6 MB Posted

Attached to
25B-143 GROUNDWATER SAMPLING AND ANALYSIS
Solicitation number
25B-143
Issued by
Marion County, Florida

About this file

This document is a private water well sampling report prepared by Andreyev Engineering, Inc. for the Marion County Solid Waste Department and the Florida Department of Environmental Protection (FDEP), focusing on groundwater sampling from eight private drinking water wells located within a half-mile of the former Newton Landfill in Ocala, Marion County, Florida. The sampling was conducted on July 26, 2023, as part of an ongoing environmental monitoring program that has been in place since the early 1990s, with the primary goal of proactively addressing water quality concerns for property owners near the landfill site.

The water quality analysis tested for multiple constituents including seven metals, arsenic, mercury, 35 volatile organic compounds (VOCs), and various water quality parameters. The results indicated that seven of the eight wells demonstrated good water quality, with no exceedances of primary drinking water standards. Only one well (NPW-35) showed a secondary drinking water standard exceedance for total dissolved solids (TDS), with concentrations of 528 and 555 mg/L against the 500 mg/L standard. Arsenic was detected in six wells but remained well below the 10 ug/L drinking water standard, with a maximum concentration of 2.2 ug/L. No volatile organic compounds were detected in any of the sampled wells, and the sampling was performed with homeowner permission, with Marion County committed to honoring homeowners' privacy preferences.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

September 20, 2023 Project No. GPEN-20-014

TO: Florida Department of Environmental Protection

3319 Maguire Boulevard Suite 232 Orlando, Florida 32803

ATTENTION: Ms. Maria Labrador, Engineering Specialist

SUBJECT: Private Water Well Sampling July 26, 2023, Vicinity of the Former

Newton Landfill, WCU Site ID: ERIC_11054 1750 NW 100th Street Ocala, Marion County, Florida

Dear Ms. Labrador:

On behalf of the Marion County Solid Waste Department, Andreyev Engineering, Inc. (AEI) is providing the results of groundwater sampling from eight (8) private drinking water wells located within ½ mile of the former Newton Landfill. This letter report includes a map of the sampling locations, sampling documentation, the laboratory results, and a summary table.

During a meeting with Florida Department of Environmental Protection (FDEP) it was requested that Marion County share the results of private water well sampling, for private wells in the vicinity of the landfill. The last time private well sampling was conducted by Marion County near the Newton Landfill was July 27, 2022, summarized in a letter to you on September 30, 2022.

Collection of groundwater samples from private wells is done with the homeowner’s understanding that the results are shared with FDEP. That said, Marion County has always strived to honor home owners’ wishes to keep private well information private.

Background

Marion County has been sampling off-site private drinking water wells since the early 1990s.

Figure 1.1 is a topographic map showing the location of the Newton Landfill. Figure 2.1 illustrates the locations of the eight private water wells sampled on July 26, 2023, and the locations of other private wells which were first sampled for the 1994 Contamination Assessment Report (CAR).

Private water well sampling was initiated before a complete network of on- and off-site monitoring wells was installed at the former Newton Landfill. Marion County has continued limited private well sampling, out of an abundance of caution, to proactively address water quality concerns for property owners in the vicinity of the former landfill.

Marion County Solid Waste Department shares private well water quality results directly with the well owners soon after receiving them. Marion County includes the private well data under a

Private Well Sampling Vicinity of the Former Newton Landfill Marion County, Florida separate letter-report, rather than include private well data with the Newton Landfill semi-annual groundwater monitoring report.

The report titled Semi-Annual Groundwater Monitoring Report Event #26 – July 2023 for the Former Newton Landfill (ERIC_11054) was submitted to FDEP the same date as this letter report.

That report describes the lateral and vertical extent of groundwater impacts from the former Newton Landfill undergoing monitored natural attenuation (MNA) at on-site and off-site wells.

Methods

Prior to the sample date, Marion County received permission forms from four homeowners to sample their private water wells. On July 26, 2022, sampling technicians from Ideal Tech Services, Inc., working on behalf of Marion County, sampled groundwater from the eight private drinking water wells identified as follows: NPW-2, NPW-12, NPW-25, NPW-31, NPW-32, NPW- 34, NPW-35 and NPW-38.

FDEP SOP #FS 2212 requires that at least one well volume of water be purged from each well prior to collection of field parameters. Field parameter measurements were made two to three minutes apart, and groundwater purging was complete when three consecutive measurements were within applicable limits. Groundwater was pumped using the dedicated electric submersible pumps which had been installed by each owner. Readings for temperature, pH, specific conductance, dissolved oxygen and turbidity were measured until these parameters had stabilized. Copies of the groundwater sampling field logs and instrument calibration forms for the July 27, 2022 sampling event are included in Appendix A. Sampling was performed, when possible, using a sampling tap located between the well and the pressure tank.

The sample kits (samples bottles and a trip blank) were provided by Pace Analytical Laboratory.

Sample bottles were filled and immediately placed in a cooler with ice. The cooler was transported to the analytical laboratory the same day that sampling occurred. Quality Control (QC) samples included a duplicate water sample and one trip blank. The duplicate sample was collected at NPW-35, immediately after collecting the regular sample. The duplicate sample was analyzed for all the constituents of the regular sample. The trip blank followed the sample kits from the laboratory to the sampling sites and back to the laboratory. The trip blank was analyzed for volatile organic compounds (VOCs) only.

The laboratory was requested to analyze for the following constituents:

• Seven metals (Cd, Cr, Fe, Pb, Mn, Na, and Zn by EPA Method 6010)

• Arsenic (As) by ICP-MS (EPA Method 6020)

• Mercury (Hg) by EPA Method 7470

• 35 VOCs by EPA Method 8260

• Color, laboratory pH, Alkalinity, TDS

• Chloride, sulfate, ammonia, nitrate, and

• Total organic carbon (TOC)

Results

The drinking water analyses for the four private wells sampled on July 27, 2022 are summarized in Table 1. These results include field and laboratory data for NPW-2, NPW-12, NPW-25, NPW- 31, NPW-32, NPW-34, NPW-35, and NPW-38, and a duplicate sample collected at NPW-35.

Arsenic was tested at each of the 8 private wells and the arsenic concentration was below the drinking water standard, or maximum contaminant level (MCL) of 10 ug/L at each of the wells.

Arsenic was detected above the laboratory method detection limit (MDL) value of 0.5 ug/L at six of the eight private wells with maximum concentration of 2.2 ug/L. Groundwater sampled from all eight private wells had arsenic concentrations well below the primary drinking water standard of 10 ug/L.

No volatile organic compounds (VOCs) by EPA Method 8260 were detected in groundwater sampled from the four private wells (see Table 1). All testing was conducted within the prescribed hold time limits and quality control data were satisfactory.

Groundwater quality at seven of the eight wells (NPW-2, NPW-12, NPW-25, NPW-31, NPW-32, NPW-34 and NPW-38) was good and did not exceed any of the primary or secondary drinking water standards tested (see Table 1). However, the water quality results for NPW-35 and duplicate water sample “NPW-35 DUP” indicate there was an exceedance for total dissolved solids (TDS), which has a secondary drinking water standard of 500 mg/L (Chapter 62-550 F.A.C.). TDS results for the sample and duplicate sample from NPW-35 were 528 and 555 mg/L.

Except for TDS, there were no other drinking water exceedances at NPW-35. There were no exceedances for total iron, manganese, turbidity, or color (in contrast to the prior year, in July 2022). Chloride concentration at NPW-35 (88.1 and 88.7 mg/L) was elevated, but did not exceed the secondary standard of 250 mg/L.

Discussion

NPW-35 is located approximately 700 feet north of the former Newton Landfill and is considered up-gradient of the landfill and the well was previously sampled in January and July 2021, and July 2022. The recent historical data for NPW-35 show similar results for TDS and chloride in January 2021. During July 2023 the iron, manganese, color and turbidity values were similar to the values obtained in January 2021 and July 2021, and lower than the July 2022 values. At the current time we are unaware of the total depth or completion status of this well, however we suspect the well is fairly shallow.

The elevated chloride concentration at NPW-35 probably explains the secondary drinking water standard exceedance for TDS on July 26, 2023. We expect higher water level elevation (relative to July 2022) made it easier to collect a sample with low turbidity. It also appears that adequate pumping duration occurred before sampling.

Recommendations

We have no recommendations at this time.

This item has been digitally signed

Printed copies of this document are not considered signed and sealed and the signature must be verified

Should you have any questions, please do not hesitate to contact the undersigned at

(407) 330-7763.

Sincerely, ANDREYEV ENGINEERING, INC.

Raymond W. Jones, P.E. John C. Houck Vice President Senior Project Geologist FL Reg. No. 58079 ec: Ms. Lacey Larramore, Admin Manager, Marion County Solid Waste Department Mr. Mark Johnson, Director, Marion County Solid Waste Department

Mr. Jody Kirkman, P.E., Marion County; Ms. Laura Bergesi, P.E., PSM, Marion County Mr. Omar Smith, P.E., S2Li

Table 1 Water Quality Results Private Water Wells Sampled July 26, 2023 Figure 1.1 USGS Topographic Map Figure 2.1 Map of Private Wells Appendix A Instrument Calibration Sheet and Groundwater Sampling Logs Appendix B Laboratory Analytical Report

TABLES

Table 1. Water Quality Results for Private Water Wells July 26, 2023 Page 1 of 3

Analyte Standard NPW-2 NPW-12 NPW-25 Analyte Standard NPW-2 NPW-12 NPW-25 Sample Date 7/26/2023 7/26/2023 7/26/2023 Sample Date 7/26/2023 7/26/2023 7/26/2023 Field pH (Std. Units) 6.5 - 8.5** 7.14 7.0 6.88 Benzene (ug/L) 1* 0.30 U 0.30 U 0.30 U Field Temperature (deg C) -- 24.1 26.2 25.7 Bromodichloromethane (ug/L) 0.6*** 0.19 U 0.19 U 0.19 U Specific Conductance (umhos/cm) -- 389 635 596 Bromoform (ug/L) 4.4*** 0.48 U 0.48 U 0.48 U Dissolved Oxygen (mg/L) -- 2.570 4.27 4.97 Bromomethane (ug/L) 9.8*** 3.9 U 3.9 U 3.9 U REDOX or ORP (mV) -- 250.00 237.00 256.00 Carbon tetrachloride (ug/L) 3* 0.44 U 0.44 U 0.44 U Turbidity (NTU) 5* 0.20 0.20 0.30 Chlorobenzene (ug/L) 100* 0.35 U 0.35 U 0.35 U Cadmium (ug/L) 5* 0.00 U 0.33 U 0.33 U Chloroethane (ug/L) 12*** 3.7 U 3.7 U 3.7 U Chromium (ug/L) 100* 1.9 I 3.0 I 1.7 U 2-Chloroethyl vinyl ether (ug/L) -- 6.1 U 6.1 U 6.1 U Iron (ug/L) 300** 25.0 U 25.0 U 25.0 U Chloroform (ug/L) 70*** 0.56 U 0.56 U 0.56 U Lead (ug/L) 15* 2.1 U 2.1 U 2.1 U Chloromethane (ug/L) 2.7*** 0.43 U 0.43 U 0.43 U Manganese (ug/L) 50** 1.4 I 1.1 U 1.1 U Dibromochloromethane (ug/L) 0.4*** 0.45 U 0.45 U 0.45 U Sodium (mg/L) 160* 2.6 11.2 4.7 U 1,2-Dichlorobenzene (ug/L) 600* 0.60 U 0.60 U 0.60 U Zinc (ug/L) 5,000** 244.0 163 204 1,3-Dichlorobenzene (ug/L) 210*** 0.33 U 0.33 U 0.33 U Arsenic (ug/L) 10* 0.79 I 2.2 0.50 U 1,4-Dichlorobenzene (ug/L) 75* 0.28 U 0.28 U 0.28 U Mercury (ug/L) 2* 0.090 U 0.090 U 0.090 U Dichlorodifluoromethane (ug/L) 1,400*** 0.80 U 0.80 U 0.80 U Apparent Color (color units) 15** 5 10.0 10.0 1,1-Dichloroethane (ug/L) 70*** 0.34 U 0.34 U 0.34 U Alkalinity, Bicarbonate (mg/L) -- 209 248 297 1,2-Dichloroethane (ug/L) 3* 0.27 U 0.27 U 0.27 U Total Dissolved Solids (mg/L) 500** 243 426 333 1,1-Dichloroethene (ug/L) 7* 0.59 U 0.59 U 0.59 U Chloride (mg/L) 250** 3.9 I 23 8.5 cis-1,2-Dichloroethene (ug/L) 70* 0.27 U 0.27 U 0.27 U Sulfate (mg/L) 250** 2.7 I 7.4 3.1 I trans-1,2-Dichloroethene (ug/L) 100* 0.23 U 0.23 U 0.23 U Nitrogen, Ammonia (mg/L) 2.8*** 0.035 U 0.035 U 0.035 U 1,2-Dichloropropane (ug/L) 5* 0.23 U 0.23 U 0.23 U Nitrogen, Nitrate (mg/L) 10* 0.54 8.70 0.76 cis-1,3-Dichloropropene (ug/L) 0.4*** 0.17 U 0.17 U 0.17 U Total Organic Carbon (mg/L) -- 050 U 0.50 U 0.50 U trans-1,3-Dichloropropene (ug/L) 0.4*** 0.37 U 0.37 U 0.37 U

Ethylbenzene (ug/L) 700* 0.30 U 0.30 U 0.30 U Note: Methylene Chloride (ug/L) 5* 1.7 U 1.7 U 1.7 U

* Primary Drinking Water Standard (FL Chapter 62-550) Methyl-tert-butyl ether (ug/L) 20*** 1.2 U 1.2 U 1.2 U ** Secondary Drinking Water Standard (FL Chapter 62-550) 1,1,2,2-Tetrachloroethane (ug/L) 1.3*** 0.59 U 0.59 U 0.59 U *** FL Chapter 62-777 Groundwater Cleanup Target Level (GCTL) Tetrachloroethene (ug/L) 5* 0.38 U 0.38 U 0.38 U --- No Standard or Criteria Available Toluene (ug/L) 1,000* 0.33 U 0.33 U 0.33 U Results from Pace Analytical Report to Aqua Pure W&SS, LLC dated February 9, 2022 1,1,1-Trichloroethane (ug/L) 200* 0.30 U 0.30 U 0.30 U "(I)" The reported value is between the lab's method detection limit (MDL) and the practical quantitation limit (PQL). 1,1,2-Trichloroethane (ug/L) 5* 0.30 U 0.30 U 0.30 U "U" Indicates the element or compound was analyzed for, but not detected. Trichloroethene (ug/L) 3* 0.36 U 0.36 U 0.36 U ug/L micrograms per liter Trichlorofluoromethane (ug/L) 2,100*** 0.72 U 0.72 U 0.72 U mg/L miligrams per liter Bold indicates an exceedance of secondary drinking water standard. Vinyl chloride (ug/L) 1* 0.39 U 0.39 U 0.39 U

Red Indicates an exceedance of primary drinking water standard. Xylene (Total) (ug/L) 10,000* 2.1 U 2.1 U 2.1 U

Table 1. Water Quality Results for Provate Water Wells July 26, 2023 Page 2 of 3

Analyte Standard NPW-31 NPW-32 NPW-34 Analyte Standard NPW-31 NPW-32 NPW-34 Sample Date 7/26/2023 7/26/2023 7/26/2023 Sample Date 7/26/2023 7/26/2023 7/26/2023 Field pH (Std. Units) 6.5 - 8.5** 6.96 7.22 7.11 Benzene (ug/L) 1* 0.30 U 0.30 U 0.30 U Field Temperature (deg C) -- 22.9 23.6 23.3 Bromodichloromethane (ug/L) 0.6*** 0.19 U 0.19 U 0.19 U Specific Conductance (umhos/cm) -- 612 317 428 Bromoform (ug/L) 4.4*** 0.48 U 0.48 U 0.48 U Dissolved Oxygen (mg/L) -- 4.810 1.3 2.9 Bromomethane (ug/L) 9.8*** 3.9 U 3.9 U 3.9 U REDOX or ORP (mV) -- 239.00 221.00 239.00 Carbon tetrachloride (ug/L) 3* 0.44 U 0.44 U 0.44 U Turbidity (NTU) 5* 0.80 1.60 0.20 Chlorobenzene (ug/L) 100* 0.35 U 0.35 U 0.35 U Cadmium (ug/L) 5* 0.33 U 0.33 U 0.33 U Chloroethane (ug/L) 12*** 3.7 U 3.7 U 3.7 U Chromium (ug/L) 100* 1.7 U 2.3 I 1.7 U 2-Chloroethyl vinyl ether (ug/L) -- 6.1 U 6.1 U 6.1 U Iron (ug/L) 300** 135 164 25.0 U Chloroform (ug/L) 70*** 0.56 U 0.56 U 0.56 U Lead (ug/L) 15* 2.1 U 2.1 U 2.1 U Chloromethane (ug/L) 2.7*** 0.43 U 0.43 U 0.43 U Manganese (ug/L) 50** 2.4 I 2.3 I 1.1 U Dibromochloromethane (ug/L) 0.4*** 0.45 U 0.45 U 0.45 U Sodium (mg/L) 160* 10 4.5 8.4 1,2-Dichlorobenzene (ug/L) 600* 0.60 U 0.60 U 0.60 U Zinc (ug/L) 5,000** 655.0 213 21.0 1,3-Dichlorobenzene (ug/L) 210*** 0.33 U 0.33 U 0.33 U Arsenic (ug/L) 10* 1.9 0.63 I 1.9 1,4-Dichlorobenzene (ug/L) 75* 0.28 U 0.28 U 0.28 U Mercury (ug/L) 2* 0.090 U 0.090 U 0.090 U Dichlorodifluoromethane (ug/L) 1,400*** 0.80 U 0.80 U 0.80 U Apparent Color (color units) 15** 10.0 10.0 5.0 1,1-Dichloroethane (ug/L) 70*** 0.34 U 0.34 U 0.34 U Alkalinity, Bicarbonate (mg/L) -- 271 143 195 1,2-Dichloroethane (ug/L) 3* 0.27 U 0.27 U 0.27 U Total Dissolved Solids (mg/L) 500** 262 180 264 1,1-Dichloroethene (ug/L) 7* 0.59 U 0.59 U 0.59 U Chloride (mg/L) 250** 28.2 11.0 13.2 cis-1,2-Dichloroethene (ug/L) 70* 0.27 U 0.27 U 0.27 U Sulfate (mg/L) 250** 3.4 I 4.8 I 12.4 trans-1,2-Dichloroethene (ug/L) 100* 0.23 U 0.23 U 0.23 U Nitrogen, Ammonia (mg/L) 2.8*** 0.035 U 0.052 0.035 U 1,2-Dichloropropane (ug/L) 5* 0.23 U 0.23 U 0.23 U Nitrogen, Nitrate (mg/L) 10* 1.6 0.54 2.40 cis-1,3-Dichloropropene (ug/L) 0.4*** 0.17 U 0.17 U 0.17 U Total Organic Carbon (mg/L) -- 0.50 U 0.50 U 0.50 U trans-1,3-Dichloropropene (ug/L) 0.4*** 0.37 U 0.37 U 0.37 U

Ethylbenzene (ug/L) 700* 0.30 U 0.30 U 0.30 U Note: Methylene Chloride (ug/L) 5* 1.7 U 1.7 U 1.7 U

* Primary Drinking Water Standard (FL Chapter 62-550) Methyl-tert-butyl ether (ug/L) 20*** 1.2 U 1.2 U 1.2 U ** Secondary Drinking Water Standard (FL Chapter 62-550) 1,1,2,2-Tetrachloroethane (ug/L) 1.3*** 0.59 U 0.59 U 0.59 U *** FL Chapter 62-777 Groundwater Cleanup Target Level (GCTL) Tetrachloroethene (ug/L) 5* 0.38 U 0.38 U 0.38 U --- No Standard or Criteria Available Toluene (ug/L) 1,000* 0.33 U 0.33 U 0.33 U Results from Pace Analytical Report to Aqua Pure W&SS, LLC dated February 9, 2022 1,1,1-Trichloroethane (ug/L) 200* 0.30 U 0.30 U 0.30 u "(I)" The reported value is between the lab's method detection limit (MDL) and the practical quantitation limit (PQL). 1,1,2-Trichloroethane (ug/L) 5* 0.30 U 0.30 U 0.30 U "U" Indicates the element or compound was analyzed for, but not detected. Trichloroethene (ug/L) 3* 0.36 U 0.36 U 0.36 u ug/L micrograms per liter Trichlorofluoromethane (ug/L) 2,100*** 0.72 U 0.72 U 0.72 U mg/L miligrams per liter Bold indicates an exceedance of secondary drinking water standard. Vinyl chloride (ug/L) 1* 0.39 U 0.39 U 0.39 U

Red Indicates an exceedance of primary drinking water standard. Xylene (Total) (ug/L) 10,000* 2.1 U 2.1 U 2.1 U

Taable 1. Water Quality Results for Private Water Wells July 26, 2023 Page 3 of 3

Analyte Standard NPW-35 NPW-35 DUP NPW-38 Analyte Standard NPW-35 NPW-35 DUP NPW-38 Sample Date 7/26/2023 7/26/2023 7/26/2023 Sample Date 7/26/2023 7/26/2023 7/26/2023 Field pH (Std. Units) 6.5 - 8.5** 7.0 7.0 7.2 Benzene (ug/L) 1* 0.30 U 0.30 U 0.30 U Field Temperature (deg C) -- 23.4 23.4 22.5 Bromodichloromethane (ug/L) 0.6*** 0.19 U 0.19 U 0.19 U Specific Conductance (umhos/cm) -- 927 927 404 Bromoform (ug/L) 4.4*** 0.48 U 0.48 U 0.48 U Dissolved Oxygen (mg/L) -- 3.270 3.27 0.76 Bromomethane (ug/L) 9.8*** 3.9 U 3.9 U 3.9 U REDOX or ORP (mV) -- 232.00 232.00 228.00 Carbon tetrachloride (ug/L) 3* 0.44 U 0.44 U 0.44 U Turbidity (NTU) 5* 1.20 1.20 0.20 Chlorobenzene (ug/L) 100* 0.35 U 0.35 U 0.35 U Cadmium (ug/L) 5* 0.33 U 0.33 U 0.33 U Chloroethane (ug/L) 12*** 3.7 U 3.7 U 3.7 U Chromium (ug/L) 100* 1.7 U 1.7 U 1.7 U 2-Chloroethyl vinyl ether (ug/L) -- 6.1 U 6.1 U 6.1 U Iron (ug/L) 300** 109 120 25.0 U Chloroform (ug/L) 70*** 0.56 U 0.56 U 0.56 U Lead (ug/L) 15* 2.1 U 2.1 U 2.1 U Chloromethane (ug/L) 2.7*** 0.43 U 0.43 U 0.43 U Manganese (ug/L) 50** 2.1 I 2.2 I 1.1 U Dibromochloromethane (ug/L) 0.4*** 0.45 U 0.45 U 0.45 U Sodium (mg/L) 160* 25.9 256 5.3 1,2-Dichlorobenzene (ug/L) 600* 0.60 U 0.60 U 0.60 U Zinc (ug/L) 5,000** 54.3 53.9 96.7 1,3-Dichlorobenzene (ug/L) 210*** 0.33 U 0.33 U 0.33 U Arsenic (ug/L) 10* 0.50 U 0.50 U 0.75 I 1,4-Dichlorobenzene (ug/L) 75* 0.28 U 0.28 U 0.28 U Mercury (ug/L) 2* 0.090 U 0.090 U 0.090 U Dichlorodifluoromethane (ug/L) 1,400*** 0.80 U 0.80 U 0.80 U Apparent Color (color units) 15** 15.0 10 10.0 1,1-Dichloroethane (ug/L) 70*** 0.34 U 0.34 U 0.34 U Alkalinity, Bicarbonate (mg/L) -- 289 289 200 1,2-Dichloroethane (ug/L) 3* 0.27 U 0.27 U 0.27 U

Total Dissolved Solids (mg/L) 500** 528 555 248 1,1-Dichloroethene (ug/L) 7* 0.59 U 0.59 U 0.59 U Chloride (mg/L) 250** 88.1 88.7 9 cis-1,2-Dichloroethene (ug/L) 70* 0.27 U 0.27 U 0.27 U Sulfate (mg/L) 250** 5.3 5.3 10.4 trans-1,2-Dichloroethene (ug/L) 100* 0.23 U 0.23 U 0.23 U Nitrogen, Ammonia (mg/L) 2.8*** 0.035 U 0.035 U 0.035 U 1,2-Dichloropropane (ug/L) 5* 0.23 U 0.23 U 0.23 U Nitrogen, Nitrate (mg/L) 10* 1.2 1.10 0.52 cis-1,3-Dichloropropene (ug/L) 0.4*** 0.17 U 0.17 U 0.17 U Total Organic Carbon (mg/L) -- 0.50 U 0.50 U 0.50 U trans-1,3-Dichloropropene (ug/L) 0.4*** 0.37 U 0.37 U 0.37 U

Ethylbenzene (ug/L) 700* 0.30 U 0.30 U 0.30 U Note: Methylene Chloride (ug/L) 5* 1.7 U 1.7 U 1.7 U 7

* Primary Drinking Water Standard (FL Chapter 62-550) Methyl-tert-butyl ether (ug/L) 20*** 1.2 U 1.2 U 1.2 U ** Secondary Drinking Water Standard (FL Chapter 62-550) 1,1,2,2-Tetrachloroethane (ug/L) 1.3*** 0.59 U 0.59 U 0.59 U *** FL Chapter 62-777 Groundwater Cleanup Target Level (GCTL) Tetrachloroethene (ug/L) 5* 0.38 U 0.38 U 0.38 U --- No Standard or Criteria Available Toluene (ug/L) 1,000* 0.33 U 0.33 U 0.33 U Results from Pace Analytical Report to Aqua Pure W&SS, LLC dated February 9, 2022 1,1,1-Trichloroethane (ug/L) 200* 0.30 U 0.30 U 0.30 U "(I)" The reported value is between the lab's method detection limit (MDL) and the practical quantitation limit (PQL). 1,1,2-Trichloroethane (ug/L) 5* 0.30 U 0.30 U 0.30 U "U" Indicates the element or compound was analyzed for, but not detected. Trichloroethene (ug/L) 3* 0.36 U 0.36 U 0.36 U ug/L micrograms per liter Trichlorofluoromethane (ug/L) 2,100*** 0.72 U 0.72 U 0.72 U mg/L miligrams per liter Bold indicates an exceedance of secondary drinking water standard. Vinyl chloride (ug/L) 1* 0.39 U 0.39 U 0.39 U

Red Indicates an exceedance of primary drinking water standard. Xylene (Total) (ug/L) 10,000* 2.1 U 2.1 U 2.1 U

FIGURES

PROJECT

AREA

Andreyev Engineering, Inc.0

GRAPHIC SCALE: 1"=2000'

2000 40001000

FORMER NEWTON LANDFILL

NPW-33

NPW-35

NPW-34 NPW-38

NPW-32NPW-2

Andreyev Engineering, Inc.0

GRAPHIC SCALE: 1"=1000'

1000 2000500

FORMER NEWTON LANDFILL

APPENDIX A

INSTRUMENT CALIBRATION SHEET AND

GROUNDWATER SAMPLING LOGS

JULY 26, 2023

CLIENT:

ADDRESS:

CITY, STATE: Site:

INITIAL CAL DATE @ TIME: @ CCV CALIBRATION DATE @ TIME: @

± 0.00

Remarks:

Weather Conditions: clear sunny 90° - 95° F Late Day Rain

Equipment Blank with Publix purified water

PRO MAY 10 2023 11:22 F5

EXP DEC 06 2023 PLT 12-506

Equipment Blank Collected @

COPY TO: Lisa Saupp SIGNED:

Chris Monaco or Karen LeBeau

Standards prepared by USA Blue Book. All standards are potassium chloride solutions.

NONE COLLECTED

2GL026

1,000

Barometer mm/Hg

.18

± 6.5%

± 10%

2,766

METER READING

Dec-23

33.4

METER READING

.21

Zero D.O. standard is Sodium Sulfite, Cobalt Chloride Hexahydrate, Water prepared by USA Blue Book.

Limit is ± 0.3 mg/L of theoretical value (see Table FT 1500-1)

.02

Feb-24

NM

AP-NPW-3005-072623ITS Work Order Number:

Standard is ORP solution, prepared by USA Blue Book. Cal Limit is ± 5% @ 25° C

199 202 3GC626

VERIFIED VALUE mg/L

0.00

25.7

6.99

CCV

01/30/23

N/A

YSI Temperature Sensor Check Per DEP-SOP-001/01 FT 1400

METER

NUMBER

DATE PERFORMED

(Quarterly)

3GD638

STANDARD

Standard Units

LOT NUMBER

pH Sensor Per DEP-SOP-001/01 FT 1100

CALIBRATION LOG

759.7

Apr-24

EXPIRATION DATE

6.30

Notes: NA - Not Applicable, NM - Not Measured, ICV - Initial Calibration Verification, CCV - Continuing Calibration Verification Revision 9.39 05/30/23 update standards and D.I. water

399 401

Standard is HACH DPD Chlorine LR secondary GEL Standard. Lot A5318 Verified 01/30/23

MFGR VALUE mg/L

.92

NM

.90

Conductivity Sensor Per DEP-SOP-001/01 FT 1200

87 Dec-23

3GB255

1.61

Liquid Temp °C

9.98

7/26/23

METER READING

CCV (± 0.2 SU)

3.99

ICV (± 0.2 SU)

All equipment used to obtain data at this site is owned, operated, and maintained by Ideal Tech Services Inc., unless otherwise noted. All equipment was purchased new from themanufacturers or authorized distributors. Preventative maintenance will be performed at the intervals specified by the manufacturer of each piece of equipment, or when equipment calibration results are out of tolerance. Equipment maintenance logs will be maintained by Ideal Tech Services Inc.

Dissolved Oxygen Sensor Per DEP-SOP-001/01 FT 1500

Start: ORP Sensor Per DEP-SOP-001/01 FT 2100 End:

± 5.0%

± 10%

N/A

Ambient Air Temperature

No CCV Limit

INITIAL

7.15

.04

CCV METER mg/L (± 10%)

0.00

0.00

7/26/23

INITIAL

LOT NUMBER

Standards prepared by Oakton

7.00

EXP DATE

INITIAL

CC767905

YSI Multi Parameter Meter: YSI-PRO+ ITS #4

3.994.005

Fluke Infrared Thermoneter S.N. 13730781 Both Certified By Aqua Pure Once Per Year 1/3/23

N/A

01/30/2330.00 ITS YSI #4HIGH

Nephelometric Turbidity Unit (NTU) Standards are prepared by Pro Cal Set# 39845, Lot# 221225

EXP: Nov / 2024 1000 EXP: Dec / 2024, .02 and 10.

N/M0.00 N/A

6.99 CC771499 Feb-25

ᵒ C

30.00

Newton Landfill PW's

Dec-244.02

METER READING

7.000

ITS YSI #2

LOW

INITIAL

.05

761.8

Thermometer is N.I.S.T. certified and manufactured by ERTCO, S/N 2206. YSI is checked against ERTCO

HIGH 0.00

6.30

N/M

Feb-24

HF SCIENTIFIC MICRO TPW TURBIDITY METER - MODEL # 20000 SN 2021010003

Per DEP-SOP-001/01 FT 1600 ITS-3-NTU

STANDARD (ntu)

METER READING CCV

Acceptance % of standard value

0.02 .02

8,974

1.60

NMNM

2STANDARD ID

HACH POCKET COLORIMETER II S/N 06070D052733

EXPIRATION DATESTANDARD (mV)

CCV BLANK

9.98

ITS YSI #2

2GE397

STANDARD

µmhos/cm

LOT NUMBER EXPIRATION DATE

INITIAL CCV (± 5%)

10.012 10.00 CC756199 Jun-24

25.7

ITS YSI #4

Initial Calibration and CCV Daily for D.O. Date:

LOT NUMBER

Aqua Pure Water & Sewage Service LLC

3855 East Silver Springs Blvd., Unit #107

Ocala, Florida 34470

TEMP READING ᵒC

May-23NM NM

2,764 2,763 3GB1133

STANDARD ᵒC

ERTCO

Thermometer

± .5 ᵒC

YSI METER

LOW

LOW HIGH

25.7 8.10

ᵒ C

CCV (± 0.3 mg/L)

STANDARD (mg/L)

33.4

Site

Name: Site Location: Marion County, Florida

Well No: NPW-2 1935 NW 100th Street WACS Well Number: Not provided18891 Date: 7/26/2023

Well Screen Interval (ft):

4 NA unknown to unkown NA in place plumbing

Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)

= ( Feet - NA Feet) * 0.16 Gallons/Ft= Gallons

Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)

Gallons + ( 0.006 Gallons/Ft * Feet) + 0.032 FCV = Gallons

Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):

In Well (ft): In Well (ft):

Time

Volume

Purged

(gallons)

Total

Volume

Purged

(gallons)

Purge

Rate

(gpm)

Depth to

Water

(feet) pH

(standard units)

Temp

(°C)

COND

(µS/cm)

Dissolved

Oxygen

(mg/L)

Turbidity

(NTUs)

COLOR

(describe)

ODOR

(describe)

1410 1.50 7.50 7.50 in place plumbing 7.14 24.1 389 2.57 .20 none none

Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:

Chris Monaco or Karen LeBeau

Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:

Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)

Field Decontamination Pump: Tubing Replaced: Duplicate:

Sample ID Code # Containers Material Code Volume Preservative Final pH

NPW-2 1 PE 1 L 6°C Not Required in place plumbing 946

NPW-2 3 CG 40 ml HCL Not Required in place plumbing 100

NPW-2 2 CG 40 ml HCL Not Required in place plumbing 946

NPW-2 1 PE 250 ml H₂SO₄ <2 in place plumbing 946

NPW-2 1 PE 250 ml HNO₃ <2 in place plumbing 946

Remarks:

ORP = 250.00

MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)

SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;

SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)

WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88

TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016

NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.

2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 o C Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);

optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater) in place plumbing in place plumbing 1405 1410 7.50

Began sampling by locating hose bib closest to well then turning it on allowing it to flow wide open for 5 minutes then the flow was slowed to 1.5 GPM. Once water quality parameters were stable one set of well stabilization readings were collected. After completing stabilization the water flow was reduced again for sampling. The flow rate while sampling all but 40ml vials was .25 GPM, and less than .03 GPM for 40 ml vials.

Sample Container Specifications

SAMPLING DATA

Intended Analysis and/or Method Sampling

Equipment Code

Cl,TDS,SO4,NO3, bic-alk, color

601 / 602 by 8260

ITS Revision 1.0 Date: 11/06/19

Sample Preservation (including wet ice)

TOC (Total Organic Carbon)

Nitrogen, Ammonia

6010 Metals

Total Volume Added In Field

None

None

None

None

None

Sample Flow

Rate (milliliters per minute)

1410 1415 in place plumbing HDPE

IDEAL TECH SERVICES, INC. GROUND WATER SAMPLE LOG

Purging Data

Well Diameter

(inches):

Tubing

Diameter

(inches):

Static Depth to Water (ft):

Purge Pump

Type:

Newton Landfill, Marion County Solid Waste

WACS facility ID 20902

YES NO

YES NOYES YESNO NO

Well No: NPW-12 2275 NW 90th Street WACS Well Number: Not provided21835 Date: 7/26/2023

Well Screen Interval (ft):

4 NA unknown to unkown NA in place plumbing

Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)

= ( Feet - NA Feet) * 0.16 Gallons/Ft= Gallons

Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)

Gallons + ( 0.006 Gallons/Ft * Feet) + 0.032 FCV = Gallons

Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):

In Well (ft): In Well (ft):

Time

Volume

Purged

(gallons)

Total

Volume

Purged

(gallons)

Purge

Rate

(gpm)

Depth to

Water

(feet) pH

(standard units)

Temp

(°C)

COND

(µS/cm)

Dissolved

Oxygen

(mg/L)

Turbidity

(NTUs)

COLOR

(describe)

ODOR

(describe)

1521 1.50 7.50 7.50 in place plumbing 7.00 26.2 635 4.27 .20 none none

Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:

Chris Monaco or Karen LeBeau

Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:

Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)

Field Decontamination Pump: Tubing Replaced: Duplicate:

Sample ID Code # Containers Material Code Volume Preservative Final pH

NPW-12 1 PE 1 L 6°C Not Required in place plumbing 946

NPW-12 3 CG 40 ml HCL Not Required in place plumbing 100

NPW-12 2 CG 40 ml HCL Not Required in place plumbing 946

NPW-12 1 PE 250 ml H₂SO₄ <2 in place plumbing 946

NPW-12 1 PE 250 ml HNO₃ <2 in place plumbing 946

Remarks:

ORP = 237.00

MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)

SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;

SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)

WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88

TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016

IDEAL TECH SERVICES, INC. GROUND WATER SAMPLE LOG

Purging Data

Well Diameter

(inches):

Tubing

Diameter

(inches):

Static Depth to Water (ft):

Purge Pump

Type:

Newton Landfill, Marion County Solid Waste

WACS facility ID 20902

1521 1526 in place plumbing PE

ITS Revision 1.0 Date: 11/06/19

Sample Preservation (including wet ice)

TOC (Total Organic Carbon)

Nitrogen, Ammonia

6010 Metals

Total Volume Added In Field

None

None

None

None

None

Sample Flow

Rate (milliliters per minute)

NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.

2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 o C Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);

optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater) in place plumbing in place plumbing 1516 1521 7.50

Began sampling by locating hose bib closest to well then turning it on allowing it to flow wide open for 5 minutes then the flow was slowed to 1.5 GPM. Once water quality parameters were stable one set of well stabilization readings were collected. After completing stabilization the water flow was reduced again for sampling. The flow rate while sampling all but 40ml vials was .25 GPM, and less than .03 GPM for 40 ml vials.

Sample Container Specifications

SAMPLING DATA

Intended Analysis and/or Method Sampling

Equipment Code

Cl,TDS,SO4,NO3, bic-alk, color

601 / 602 by 8260

Well No: NPW-25 2180 NW 100th Street WACS Well Number: Not provided19127 Date: 7/26/2023

Well Screen Interval (ft):

4 NA unknown to unkown NA in place plumbing

Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)

= ( Feet - NA Feet) * 0.16 Gallons/Ft= Gallons

Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)

Gallons + ( 0.006 Gallons/Ft * Feet) + 0.032 FCV = Gallons

Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):

In Well (ft): In Well (ft):

Time

Volume

Purged

(gallons)

Total

Volume

Purged

(gallons)

Purge

Rate

(gpm)

Depth to

Water

(feet) pH

(standard units)

Temp

(°C)

COND

(µS/cm)

Dissolved

Oxygen

(mg/L)

Turbidity

(NTUs)

COLOR

(describe)

ODOR

(describe)

1424 1.50 7.50 7.50 in place plumbing 6.88 25.7 596 4.97 .30 none none

Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:

Chris Monaco or Karen LeBeau

Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:

Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)

Field Decontamination Pump: Tubing Replaced: Duplicate:

Sample ID Code # Containers Material Code Volume Preservative Final pH

NPW-25 1 PE 1 L 6°C Not Required in place plumbing 946

NPW-25 3 CG 40 ml HCL Not Required in place plumbing 100

NPW-25 2 CG 40 ml HCL Not Required in place plumbing 946

NPW-25 1 PE 250 ml H₂SO₄ <2 in place plumbing 946

NPW-25 1 PE 250 ml HNO₃ <2 in place plumbing 946

Remarks:

ORP = 256.00

MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)

SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;

SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)

WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88

TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016

NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.

2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 o C Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);

optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater) in place plumbing in place plumbing 1419 1424 7.50

Began sampling by locating hose bib closest to well then turning it on allowing it to flow wide open for 5 minutes then the flow was slowed to 1.5 GPM. Once water quality parameters were stable one set of well stabilization readings were collected. After completing stabilization the water flow was reduced again for sampling. The flow rate while sampling all but 40ml vials was .25 GPM, and less than .03 GPM for 40 ml vials.

Sample Container Specifications

SAMPLING DATA

Intended Analysis and/or Method Sampling

Equipment Code

Cl,TDS,SO4,NO3, bic-alk, color

601 / 602 by 8260

ITS Revision 1.0 Date: 11/06/19

Sample Preservation (including wet ice)

TOC (Total Organic Carbon)

Nitrogen, Ammonia

6010 Metals

Total Volume Added In Field

None

None

None

None

None

Sample Flow

Rate (milliliters per minute)

1424 1429 in place plumbing PE

IDEAL TECH SERVICES, INC. GROUND WATER SAMPLE LOG

Purging Data

Well Diameter

(inches):

Tubing

Diameter

(inches):

Static Depth to Water (ft):

Purge Pump

Type:

Newton Landfill, Marion County Solid Waste

WACS facility ID 20902

Well No: NPW-31 1311 NW 100th Street WACS Well Number: Not provided20769 Date: 7/26/2023

Well Screen Interval (ft):

4 NA unknown to unkown NA in place plumbing

Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)

= ( Feet - NA Feet) * 0.16 Gallons/Ft= Gallons

Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)

Gallons + ( 0.006 Gallons/Ft * Feet) + 0.032 FCV = Gallons

Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):

In Well (ft): In Well (ft):

Time

Volume

Purged

(gallons)

Total

Volume

Purged

(gallons)

Purge

Rate

(gpm)

Depth to

Water

(feet) pH

(standard units)

Temp

(°C)

COND

(µS/cm)

Dissolved

Oxygen

(mg/L)

Turbidity

(NTUs)

COLOR

(describe)

ODOR

(describe)

1443 7.50 7.50 1.50 in place plumbing 6.96 22.9 612 4.81 .80 none none

Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:

Chris Monaco or Karen LeBeau

Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:

Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)

Field Decontamination Pump: Tubing Replaced: Duplicate:

Sample ID Code # Containers Material Code Volume Preservative Final pH

NPW-31 1 PE 1 L 6°C Not Required in place plumbing 946

NPW-31 3 CG 40 ml HCL Not Required in place plumbing 100

NPW-31 2 CG 40 ml HCL Not Required in place plumbing 946

NPW-31 1 PE 250 ml H₂SO₄ <2 in place plumbing 946

NPW-31 1 PE 250 ml HNO₃ <2 in place plumbing 946

Remarks:

ORP = 239.00

MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)

SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;

SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)

WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88

TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016

NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.

2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 o C Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);

optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater) in place plumbing in place plumbing 1438 1443 7.50

Began sampling by locating hose bib closest to well then turning it on allowing it to flow wide open for 5 minutes then the flow was slowed to 1.5 GPM. Once water quality parameters were stable one set of well stabilization readings were collected. After completing stabilization the water flow was reduced again for sampling. The flow rate while sampling all but 40ml vials was .25 GPM, and less than .03 GPM for 40 ml vials.

Sample Container Specifications

SAMPLING DATA

Intended Analysis and/or Method Sampling

Equipment Code

Cl,TDS,SO4,NO3, bic-alk, color

601 / 602 by 8260

ITS Revision 1.0 Date: 11/06/19

Sample Preservation (including wet ice)

TOC (Total Organic Carbon)

Nitrogen, Ammonia

6010 Metals

Total Volume Added In Field

None

None

None

None

None

Sample Flow

Rate (milliliters per minute)

1443 1448 in place plumbing PE

IDEAL TECH SERVICES, INC. GROUND WATER SAMPLE LOG

Purging Data

Well Diameter

(inches):

Tubing

Diameter

(inches):

Static Depth to Water (ft):

Purge Pump

Type:

Newton Landfill, Marion County Solid Waste

WACS facility ID 20902

Well No: NPW-32 851 NW 100th St WACS Well Number: Not provided Date: 7/26/2023

Well Screen Interval (ft):

4 NA unknown to unkown NA in place plumbing

Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)

= ( Feet - NA Feet) * 0.16 Gallons/Ft= Gallons

Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)

Gallons + ( 0.006 Gallons/Ft * Feet) + 0.032 FCV = Gallons

Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):

In Well (ft): In Well (ft):

Time

Volume

Purged

(gallons)

Total

Volume

Purged

(gallons)

Purge

Rate

(gpm)

Depth to

Water

(feet) pH

(standard units)

Temp

(°C)

COND

(µS/cm)

Dissolved

Oxygen

(mg/L)

Turbidity

(NTUs)

COLOR

(describe)

ODOR

(describe)

1459 7.50 7.50 1.50 in place plumbing 7.22 23.6 317 1.30 1.60 none none

Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:

Chris Monaco or Karen LeBeau

Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:

Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)

Field Decontamination Pump: Tubing Replaced: Duplicate:

Sample ID Code # Containers Material Code Volume Preservative Final pH

NPW-32 1 PE 1 L 6°C Not Required in place plumbing 946

NPW-32 3 CG 40 ml HCL Not Required in place plumbing 100

NPW-32 2 CG 40 ml HCL Not Required in place plumbing 946

NPW-32 1 PE 250 ml H₂SO₄ <2 in place plumbing 946

NPW-32 1 PE 250 ml HNO₃ <2 in place plumbing 946

Remarks:

ORP = 221.00

MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)

SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;

SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)

WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88

TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016

IDEAL TECH SERVICES, INC. GROUND WATER SAMPLE LOG

Purging Data

Well Diameter

(inches):

Tubing

Diameter

(inches):

Static Depth to Water (ft):

Purge Pump

Type:

Newton Landfill, Marion County Solid Waste

WACS facility ID 20902

1459 1504 in place plumbing PE

ITS Revision 1.0 Date: 11/06/19

Sample Preservation (including wet ice)

TOC (Total Organic Carbon)

Nitrogen, Ammonia

6010 Metals

Total Volume Added In Field

None

None

None

None

None

Sample Flow

Rate (milliliters per minute)

NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.

2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 o C Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);

optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater) in place plumbing in place plumbing 1454 1459 1.50

Began sampling by locating hose bib closest to well then turning it on allowing it to flow wide open for 5 minutes then the flow was slowed to 1.5 GPM. Once water quality parameters were stable one set of well stabilization readings were collected. After completing stabilization the water flow was reduced again for sampling. The flow rate while sampling all but 40ml vials was .25 GPM, and less than .03 GPM for 40 ml vials.

Sample Container Specifications

SAMPLING DATA

Intended Analysis and/or Method Sampling

Equipment Code

Cl,TDS,SO4,NO3, bic-alk, color

601 / 602 by 8260

Well No: NPW-34 1821 NW 100th Street WACS Well Number: Not provided Date: 7/26/2023

Well Screen Interval (ft):

4 NA unknown to unkown NA in place plumbing

Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)

= ( Feet - NA Feet) * 0.16 Gallons/Ft= Gallons

Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)

Gallons + ( 0.006 Gallons/Ft * Feet) + 0.032 FCV = Gallons

Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):

In Well (ft): In Well (ft):

Time

Volume

Purged

(gallons)

Total

Volume

Purged

(gallons)

Purge

Rate

(gpm)

Depth to

Water

(feet) pH

(standard units)

Temp

(°C)

COND

(µS/cm)

Dissolved

Oxygen

(mg/L)

Turbidity

(NTUs)

COLOR

(describe)

ODOR

(describe)

1353 7.50 7.50 1.50 in place plumbing 7.11 23.3 428 2.90 .20 none none

Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:

Chris Monaco or Karen LeBeau

Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:

Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)

Field Decontamination Pump: Tubing Replaced: Duplicate:

Sample ID Code # Containers Material Code Volume Preservative Final pH

NPW-34 1 PE 1 L 6°C Not Required in place plumbing 946

NPW-34 3 CG 40 ml HCL Not Required in place plumbing 100

NPW-34 2 CG 40 ml HCL Not Required in place plumbing 946

NPW-34 1 PE 250 ml H₂SO₄ <2 in place plumbing 946

NPW-34 1 PE 250 ml HNO₃ <2 in place plumbing 946

Remarks:

ORP = 239.00

MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)

SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;

SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)

WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88

TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016

NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.

2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 o C Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);

optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater) in place plumbing in place plumbing 1348 1353 7.50

Began sampling by locating hose bib closest to well then turning it on allowing it to flow wide open for 5 minutes then the flow was slowed to 1.5 GPM. Once water quality parameters were stable one set of well stabilization readings were collected. After completing stabilization the water flow was reduced again for sampling. The flow rate while sampling all but 40ml vials was .25 GPM, and less than .03 GPM for 40 ml vials.

Sample Container Specifications

SAMPLING DATA

Intended Analysis and/or Method Sampling

Equipment Code

Cl,TDS,SO4,NO3, bic-alk, color

601 / 602 by 8260

ITS Revision 1.0 Date: 11/06/19

Sample Preservation (including wet ice)

TOC (Total Organic Carbon)

Nitrogen, Ammonia

6010 Metals

Total Volume Added In Field

None

None

None

None

None

Sample Flow

Rate (milliliters per minute)

1353 1358 in place plumbing PE

IDEAL TECH SERVICES, INC. GROUND WATER SAMPLE LOG

Purging Data

Well Diameter

(inches):

Tubing

Diameter

(inches):

Static Depth to Water (ft):

Purge Pump

Type:

Newton Landfill, Marion County Solid Waste

WACS facility ID 20902

Well No: NPW-35 10124 NW 17th Avenue WACS Well Number: Not provided Date: 7/26/2023

Well Screen Interval (ft):

4 NA unknown to unkown NA in place plumbing

Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)

= ( Feet - NA Feet) * 0.16 Gallons/Ft= Gallons

Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)

Gallons + ( 0.006 Gallons/Ft * Feet) + 0.032 FCV = Gallons

Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):

In Well (ft): In Well (ft):

Time

Volume

Purged

(gallons)

Total

Volume

Purged

(gallons)

Purge

Rate

(gpm)

Depth to

Water

(feet) pH

(standard units)

Temp

(°C)

COND

(µS/cm)

Dissolved

Oxygen

(mg/L)

Turbidity

(NTUs)

COLOR

(describe)

ODOR

(describe)

1316 7.50 7.50 1.50 in place plumbing 7.00 23.4 927 3.27 1.20 none none

Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:

Chris Monaco or Karen LeBeau

Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:

Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)

Field Decontamination Pump: Tubing Replaced: Duplicate: NPW-DUP

Sample ID Code # Containers Material Code Volume Preservative Final pH

NPW-35 2 PE 1 L 6°C Not Required in place plumbing 946

NPW-35 6 CG 40 ml HCL Not Required in place plumbing 100

NPW-35 4 CG 40 ml HCL Not Required in place plumbing 946

NPW-35 2 PE 250 ml H₂SO₄ <2 in place plumbing 946

NPW-35 2 PE 250 ml HNO₃ <2 in place plumbing 946

Remarks:

ORP = 232.00

MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)

SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;

SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)

WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88

TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016

NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.

2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 o C Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);

optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater) in place plumbing in place plumbing 1311 1316 7.50

Began sampling by locating hose bib closest to well then turning it on allowing it to flow wide open for 5 minutes then the flow was slowed to 1.5 GPM. Once water quality parameters were stable one set of well stabilization readings were collected. After completing stabilization the water flow was reduced again for sampling. The flow rate while sampling all but 40ml vials was .25 GPM, and less than .03 GPM for 40 ml vials.

Sample Container…

This is the start of the file's text. The full file is on GovTribe.