12-25B-143 ADDENDUM 1..pdf
PDF 4 MB Posted
- Attached to
- 25B-143 GROUNDWATER SAMPLING AND ANALYSIS
- Solicitation number
- 25B-143
- Issued by
- Marion County, Florida
About this file
This document is Addendum 1 to Bid 25B-143 for Groundwater Sampling and Analysis issued by Marion County, Florida. The addendum provides clarifications and responses to bidder questions regarding a groundwater sampling contract. The solicitation involves comprehensive groundwater sampling services, including sampling of various wells (depths vary), with specific requirements for new tubing, potential infrastructure like submersible pumps, and sampling of both county and private wells. The vendor will be responsible for coordinating sampling appointments with private homeowners, using PFAS testing Method 1633 when requested, and handling site access and preparation.
The addendum removes certain line items from the original pricing sheet, such as bacteriological testing at recycling centers, and provides guidance on well cap and lock management. Marion County will provide well lists and replacement locks, while the vendor must notify the county about broken well caps. The county emphasizes that no documentation outside the formal bid submittal will be accepted, and bidders must acknowledge the addendum by signing the Proposer Requirements/Acknowledgements Form. The contract appears to be focused on detailed, site-specific groundwater sampling with flexibility for varying site conditions and well characteristics.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM TO BID 25B-143
JULY 29, 2025
TO: Participating Bidders RE: Addendum No.
Pages:99
25B-143 GROUNDWATER SAMPLING AND ANALYSIS
Please make note of the following changes, additions, deletions and clarifications to the above referenced solicitation. Whenever a conflict appears between this addendum and the initial solicitation, or plans, this addendum shall prevail, and as such shall constitute a binding portion of the contract documents. All provisions of the original specifications shall remain in force, except as specifically modified or changed herein.
A. QUESTIONS AND ANSWERS
1. Do you require new tubing for every well, it was done previously?
a. Yes.
2. Are there submersible pumps or other infrastructure already installed in these wells?
a. There are some pumps in select wells. Please review the field logs enclosed for additional information.
3. Could you confirm how many wells there are and whether they are all or mostly deep wells?
a. Well depths vary. Please refer to the ground water reports enclosed and/or field logs for the number of wells and depths of wells.
4. Regarding the sampling duration: has the total time required for each sampling event been relatively consistent across monitoring events, or does it vary significantly compared to the example reports?
a. The duration of each sampling event can vary depending on site specific conditions, well depth, and the number of wells being sampled. The field notes enclosed may provide additional information which could better answer this question.
5. The total time taken to sample all wells, do the example reports accurately reflect typical field durations, or is the total time often more or less than shown, does it vary significantly based on site conditions?
a. The reports are accurate, and our current vendor confirms that assessment. However, certain sites and wells may present additional challenges. For example, while some wells are conveniently located, you can simply drive up to the site and begin sampling others, are situated off-site behind fences.
6. I noticed there is a line-item site clearing to access wells in the pricing sheet, is that not typically handled by Marion County as part of routine maintenance?
a. Marion County does routine maintenance around wells. However, there may be occasions you come to a well that does not meet your field standards and isn’t as accessible as anticipated. In such cases, additional time may be required to properly access and prepare for sampling.
7. Is it possible to incorporate an hourly sampling rate into the pricing sheet?
a. No.
8. What testing method should be used when testing for PFAS?
a. PFAS testing will use Method 1633, when requested by the department.
9. Could you please confirm whether the replacement well cap or lock item refers to a mechanical replacement, rather than any analytical services? We want to ensure proper scope alignment, as it generally falls under field or infrastructure work not laboratory testing.
a. Marion County will remove well caps and locks from the scope and price sheet. If the vendor comes across a broken well cap, the vendor shall notify the county and provide information (site, well number, etc.) so the county can get it repaired. The county will provide the vendor with replacement locks for locks that become non-serviceable, hard to open, etc. If locks are needed, contact the county for additional locks.
10. Could you clarify whether Marion County uses a standard key system for locks accurately?
a. Yes, we do.
11. Could you confirm whether the lab or select sampling vendor should contact private well homeowners directly for sampling appointments or if Marions County’s team will coordinate access and scheduling for those private wells during standard sampling events?
a. Marion County will provide a list of private wells to be sampled. It is the vendors responsibility to coordinate with the private homeowner and coordinate sampling.
12. Regarding the private wells, do they already have an accessible sampling tap or collection point?
a. Yes, however, there is no specific standard. Some may be at the well, others in a garage, etc.
Coordination with the property owner is key.
B. Notes Regarding line item 4-1 on the pricing sheet for annual bacteriological testing at recycling centers. Marion County Utilities will be handling the testing at our recycle centers. This will be removed from the scope and pricing sheet.
It has been determined that we will not accept any documentation outside of your formal bid submittal.
Any questions or concerns related to our terms and conditions will be considered contingent upon award and may be addressed at that time, if applicable.
By signing the Proposer Requirements/Acknowledgements Form, Bidders are acknowledging receipt of this addendum. Failure to acknowledge receipt of this addendum may be cause for rejection.
CLIENT:
ADDRESS:
CITY, STATE: Site:
INITIAL CAL DATE @ TIME: @ CCV CALIBRATION DATE @ TIME: @
+ 0.02
Remarks:
Weather Conditions: clear sunny 65° - 75° F
Equipment Blank with Publix purified water
PRO Oct 15 2024 18:07 F5
EXP MAY 13 2025 PLT 12-506
Equipment Blank Collected @
COPY TO: SIGNED:
Chris Monaco
Standards prepared by USA Blue Book. All standards are potassium chloride solutions.
4GJ0937
1,000
Barometer mm/Hg
.17
± 6.5%
± 10%
2,765
METER READING
Aug-25
25.3
METER READING
.21
Zero D.O. standard is Sodium Sulfite, Cobalt Chloride Hexahydrate, Water prepared by USA Blue Book.
Limit is ± 0.3 mg/L of theoretical value (see Table FT 1500-1)
.02
Oct-25
NM
AP-BLF-3213-021725ITS Work Order Number:
Standard is ORP solution, prepared by USA Blue Book. Cal Limit is ± 5% @ 25° C
200 200 4GK0436
VERIFIED VALUE mg/L
0.00
16.8
6.99
CCV
01/03/25
N/A
YSI Temperature Sensor Check Per DEP-SOP-001/01 FT 1400
METER
NUMBER
DATE PERFORMED
(Quarterly)
4GH0018
STANDARD
Standard Units
LOT NUMBER
pH Sensor Per DEP-SOP-001/01 FT 1100
CALIBRATION LOG
763.1
Aug-25
EXPIRATION DATE
5.30
Notes: NA - Not Applicable, NM - Not Measured, ICV - Initial Calibration Verification, CCV - Continuing Calibration Verification Revision 9.47 01/16/25 update cal solutions
398 399
Standard is HACH DPD Chlorine LR secondary GEL Standard. Lot A5318 Verified 12/16/24
MFGR VALUE mg/L
.91
NM
.90
Conductivity Sensor Per DEP-SOP-001/01 FT 1200
86 Oct-25
4GJ0591
1.61
Liquid Temp °C
9.97
2/17/25
METER READING
CCV (± 0.2 SU)
3.99
ICV (± 0.2 SU)
All equipment used to obtain data at this site is owned, operated, and maintained by Ideal Tech Services Inc., unless otherwise noted. All equipment was purchased new from themanufacturers or authorized distributors. Preventative maintenance will be performed at the intervals specified by the manufacturer of each piece of equipment, or when equipment calibration results are out of tolerance. Equipment maintenance logs will be maintained by Ideal Tech Services Inc.
Dissolved Oxygen Sensor Per DEP-SOP-001/01 FT 1500
Start: ORP Sensor Per DEP-SOP-001/01 FT 2100 End:
± 5.0%
± 10%
N/A
Ambient Air Temperature
No CCV Limit
INITIAL
8.17
.04
CCV METER mg/L (± 10%)
0.00
0.00
2/17/25
INITIAL
LOT NUMBER
Standards prepared by Oakton
7.00
EXP DATE
INITIAL
CC793956
YSI Multi Parameter Meter: YSI-PRO+ ITS #4
3.994.005
Fluke Infrared Thermoneter S.N. 13730781 Both Certified By Aqua Pure Once Per Year 12/16/24
N/A
01/03/2529.90 ITS YSI #4HIGH
Nephelometric Turbidity Unit (NTU) Standards are prepared by Pro Cal Set# 39845, Lot# 250132 EXP:
Dec 2026
N/M0.00 N/A
6.99 CC798874 Mar-26
ᵒ C
29.90
Baseline Landfill SA1
Jan-263.99
METER READING
7.000
ITS YSI #2
LOW
INITIAL
.06
764.4
Thermometer is N.I.S.T. certified and manufactured by ERTCO, S/N 2206. YSI is checked against ERTCO
HIGH 0.00
5.30
N/M
May-25
HF SCIENTIFIC MICRO TPW TURBIDITY METER - MODEL # 20000 SN 2021010003
Per DEP-SOP-001/01 FT 1600 ITS-3-NTU
STANDARD (ntu)
METER READING CCV
Acceptance % of standard value
0.02 .02
8,974
1.59
NMNM
2STANDARD ID
HACH POCKET COLORIMETER II S/N 06070D052733
EXPIRATION DATESTANDARD (mV)
CCV BLANK
9.97
ITS YSI #2
4GD0514
STANDARD
µmhos/cm
LOT NUMBER EXPIRATION DATE
INITIAL CCV (± 5%)
10.012 9.98 CC791198 Nov-25
16.8
ITS YSI #4
Initial Calibration and CCV Daily for D.O. Date:
LOT NUMBER
Aqua Pure Water & Sewage Service LLC
3855 East Silver Springs Blvd., Unit #107
Ocala, Florida 34470
TEMP READING ᵒC
Apr-25NM NM
2,764 2,763 4GE1364
STANDARD ᵒC
ERTCO
Thermometer
± .5 ᵒC
YSI METER
LOW
LOW HIGH
16.8 9.64
ᵒ C
CCV (± 0.3 mg/L)
STANDARD (mg/L)
25.3
CITY, STATE: Site:
INITIAL CAL DATE @ TIME: @ CCV CALIBRATION DATE @ TIME: @
+ 0.02
Remarks:
Weather Conditions: clear sunny 60° - 75° F
Equipment Blank with Publix purified water
PRO Oct 15 2024 18:07 F5
EXP MAY 13 2025 PLT 12-506
Equipment Blank Collected @
COPY TO: SIGNED:
Chris Monaco
Aqua Pure Water & Sewage Service LLC
3855 East Silver Springs Blvd., Unit #107
Ocala, Florida 34470
TEMP READING ᵒC
Apr-25NM NM
2,764 2,764 4GE1364
STANDARD ᵒC
ERTCO
Thermometer
± .5 ᵒC
YSI METER
LOW
LOW HIGH
14.6 10.11
ᵒ C
CCV (± 0.3 mg/L)
STANDARD (mg/L)
24.3
9.97
ITS YSI #2
4GD0514
STANDARD
µmhos/cm
LOT NUMBER EXPIRATION DATE
INITIAL CCV (± 5%)
10.012 9.97 CC791198 Nov-25
14.6
ITS YSI #4
Initial Calibration and CCV Daily for D.O. Date:
LOT NUMBER
May-25
HF SCIENTIFIC MICRO TPW TURBIDITY METER - MODEL # 20000 SN 2021010003
Per DEP-SOP-001/01 FT 1600 ITS-3-NTU
STANDARD (ntu)
METER READING CCV
Acceptance % of standard value
0.02 .02
8,974
1.59
NMNM
2STANDARD ID
HACH POCKET COLORIMETER II S/N 06070D052733
EXPIRATION DATESTANDARD (mV)
CCV BLANK
N/A
7.00 CC798874 Mar-26
ᵒ C
29.90
Baseline Landfill SA1
Jan-263.99
METER READING
7.000
ITS YSI #2
LOW
INITIAL
.07
764.5
Thermometer is N.I.S.T. certified and manufactured by ERTCO, S/N 2206. YSI is checked against ERTCO
HIGH 0.00
5.30
N/M
2/18/25
INITIAL
LOT NUMBER
Standards prepared by Oakton
7.00
EXP DATE
INITIAL
CC793956
YSI Multi Parameter Meter: YSI-PRO+ ITS #4
3.994.005
Fluke Infrared Thermoneter S.N. 13730781 Both Certified By Aqua Pure Once Per Year 12/16/24
N/A
01/03/2529.90 ITS YSI #4HIGH
Nephelometric Turbidity Unit (NTU) Standards are prepared by Pro Cal Set# 39845, Lot# 250132 EXP:
Dec 2026
N/M0.00
9.97
2/18/25
METER READING
CCV (± 0.2 SU)
3.99
ICV (± 0.2 SU)
All equipment used to obtain data at this site is owned, operated, and maintained by Ideal Tech Services Inc., unless otherwise noted. All equipment was purchased new from themanufacturers or authorized distributors. Preventative maintenance will be performed at the intervals specified by the manufacturer of each piece of equipment, or when equipment calibration results are out of tolerance. Equipment maintenance logs will be maintained by Ideal Tech Services Inc.
Dissolved Oxygen Sensor Per DEP-SOP-001/01 FT 1500
Start: ORP Sensor Per DEP-SOP-001/01 FT 2100 End:
± 5.0%
± 10%
N/A
Ambient Air Temperature
No CCV Limit
INITIAL
8.35
.06
CCV METER mg/L (± 10%)
0.00
0.00
CALIBRATION LOG
762.3
Aug-25
EXPIRATION DATE
5.30
Notes: NA - Not Applicable, NM - Not Measured, ICV - Initial Calibration Verification, CCV - Continuing Calibration Verification Revision 9.47 01/16/25 update cal solutions
399 400
Standard is HACH DPD Chlorine LR secondary GEL Standard. Lot A5318 Verified 12/16/24
MFGR VALUE mg/L
.91
NM
.90
Conductivity Sensor Per DEP-SOP-001/01 FT 1200
85 Oct-25
4GJ0591
1.61
Liquid Temp °C
AP-BLF-3213-021825ITS Work Order Number:
Standard is ORP solution, prepared by USA Blue Book. Cal Limit is ± 5% @ 25° C
199 199 4GK0436
VERIFIED VALUE mg/L
0.00
14.6
7.00
CCV
01/03/25
N/A
YSI Temperature Sensor Check Per DEP-SOP-001/01 FT 1400
METER
NUMBER
DATE PERFORMED
(Quarterly)
4GH0018
STANDARD
Standard Units
LOT NUMBER
pH Sensor Per DEP-SOP-001/01 FT 1100
Standards prepared by USA Blue Book. All standards are potassium chloride solutions.
None Collected
4GJ0937
1,000
Barometer mm/Hg
.17
± 6.5%
± 10%
2,763
METER READING
Aug-25
24.3
METER READING
.21
Zero D.O. standard is Sodium Sulfite, Cobalt Chloride Hexahydrate, Water prepared by USA Blue Book.
Limit is ± 0.3 mg/L of theoretical value (see Table FT 1500-1)
.02
Oct-25
NM
CITY, STATE: Site:
INITIAL CAL DATE @ TIME: @ CCV CALIBRATION DATE @ TIME: @
+ 0.02
Remarks:
Weather Conditions: Overcast then sunny 65° - 75° F
Equipment Blank with Publix purified water
PRO Oct 15 2024 18:07 F5
EXP MAY 13 2025 PLT 12-506
Equipment Blank Collected @
COPY TO: SIGNED:
Chris Monaco
Aqua Pure Water & Sewage Service LLC
3855 East Silver Springs Blvd., Unit #107
Ocala, Florida 34470
TEMP READING ᵒC
Apr-25NM NM
2,764 2,763 4GE1364
STANDARD ᵒC
ERTCO
Thermometer
± .5 ᵒC
YSI METER
LOW
LOW HIGH
19.6 9.20
ᵒ C
CCV (± 0.3 mg/L)
STANDARD (mg/L)
24.4
9.98
ITS YSI #2
4GD0514
STANDARD
µmhos/cm
LOT NUMBER EXPIRATION DATE
INITIAL CCV (± 5%)
10.012 9.98 CC791198 Nov-25
19.6
ITS YSI #4
Initial Calibration and CCV Daily for D.O. Date:
LOT NUMBER
May-25
HF SCIENTIFIC MICRO TPW TURBIDITY METER - MODEL # 20000 SN 2021010003
Per DEP-SOP-001/01 FT 1600 ITS-3-NTU
STANDARD (ntu)
METER READING CCV
Acceptance % of standard value
0.02 .02
8,974
1.59
NMNM
2STANDARD ID
HACH POCKET COLORIMETER II S/N 06070D052733
EXPIRATION DATESTANDARD (mV)
CCV BLANK
N/A
7.00 CC798874 Mar-26
ᵒ C
29.90
Baseline Landfill SA1
Jan-264.01
METER READING
7.000
ITS YSI #2
LOW
INITIAL
.05
760.5
Thermometer is N.I.S.T. certified and manufactured by ERTCO, S/N 2206. YSI is checked against ERTCO
HIGH 0.00
5.30
N/M
2/19/25
INITIAL
LOT NUMBER
Standards prepared by Oakton
7.01
EXP DATE
INITIAL
CC793956
YSI Multi Parameter Meter: YSI-PRO+ ITS #4
4.004.005
Fluke Infrared Thermoneter S.N. 13730781 Both Certified By Aqua Pure Once Per Year 12/16/24
N/A
01/03/2529.90 ITS YSI #4HIGH
Nephelometric Turbidity Unit (NTU) Standards are prepared by Pro Cal Set# 39845, Lot# 250132 EXP:
Dec 2026
N/M0.00
9.98
2/19/25
METER READING
CCV (± 0.2 SU)
4.00
ICV (± 0.2 SU)
All equipment used to obtain data at this site is owned, operated, and maintained by Ideal Tech Services Inc., unless otherwise noted. All equipment was purchased new from themanufacturers or authorized distributors. Preventative maintenance will be performed at the intervals specified by the manufacturer of each piece of equipment, or when equipment calibration results are out of tolerance. Equipment maintenance logs will be maintained by Ideal Tech Services Inc.
Dissolved Oxygen Sensor Per DEP-SOP-001/01 FT 1500
Start: ORP Sensor Per DEP-SOP-001/01 FT 2100 End:
± 5.0%
± 10%
N/A
Ambient Air Temperature
No CCV Limit
INITIAL
8.35
.05
CCV METER mg/L (± 10%)
0.00
0.00
CALIBRATION LOG
760.0
Aug-25
EXPIRATION DATE
5.30
Notes: NA - Not Applicable, NM - Not Measured, ICV - Initial Calibration Verification, CCV - Continuing Calibration Verification Revision 9.47 01/16/25 update cal solutions
400 400
Standard is HACH DPD Chlorine LR secondary GEL Standard. Lot A5318 Verified 12/16/24
MFGR VALUE mg/L
.91
NM
.90
Conductivity Sensor Per DEP-SOP-001/01 FT 1200
85 Oct-25
4GJ0591
1.61
Liquid Temp °C
AP-BLF-3213-021925ITS Work Order Number:
Standard is ORP solution, prepared by USA Blue Book. Cal Limit is ± 5% @ 25° C
200 200 4GK0436
VERIFIED VALUE mg/L
0.00
19.6
7.00
CCV
01/03/25
N/A
YSI Temperature Sensor Check Per DEP-SOP-001/01 FT 1400
METER
NUMBER
DATE PERFORMED
(Quarterly)
4GH0018
STANDARD
Standard Units
LOT NUMBER
pH Sensor Per DEP-SOP-001/01 FT 1100
Standards prepared by USA Blue Book. All standards are potassium chloride solutions.
none collected
4GJ0937
1,000
Barometer mm/Hg
.17
± 6.5%
± 10%
2,765
METER READING
Aug-25
24.4
METER READING
.21
Zero D.O. standard is Sodium Sulfite, Cobalt Chloride Hexahydrate, Water prepared by USA Blue Book.
Limit is ± 0.3 mg/L of theoretical value (see Table FT 1500-1)
.02
Site Name: Marion County Solid Waste Baseline landfill WACS ID: 20906 Site Location: Marion County, Florida
Well No: MW-2 WACS Well Number: 12803 Date: 2/18/25
Well Screen Interval (ft): NGVD
2 0.375 50 to 60 50.23 BP
Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)
= ( 59.74 Feet - 50.23 Feet) * 0.16 Gallons/Ft= 1.52 Gallons
Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)
Gallons + ( 0.006 Gallons/Ft * 60 Feet) + 0.032 FCV = 0.392 Gallons
Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):
In Well (ft): In Well (ft):
Time
Volume
Purged
(gallons)
Total
Volume
Purged
(gallons)
Purge
Rate
(gpm)
Depth to
Water
(feet) pH
(standard units)
Temp
(°C)
COND
(µS/cm)
Dissolved
Oxygen
(mg/L)
Turbidity
(NTUs)
COLOR
(describe)
ODOR
(describe)
1310 1.50 1.50 0.25 50.32 6.19 26.0 555 0.20 13.10 none none
1312 0.50 2.00 0.25 50.32 6.20 26.1 556 0.19 12.00 none none
1314 0.50 2.50 0.25 50.32 6.23 26.0 558 0.17 11.60 none none
Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:
Chris Monaco
Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:
Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)
Field Decontamination Pump: Tubing Replaced: Duplicate:
Sample ID Code # Containers Material Code Volume Preservative Final pH
MW-2 1 PE 1 L 6°C Not Required BP 946
MW-2 1 PE 250 mL H₂SO₄ <2 BP 946
MW-2 2 CG 40 mL 6°C Not Required BP 100
MW-2 1 PE 250 mL HNO₃ <2 BP 946
MW-2 3 CG 40 mL HCl Not Required BP 100
Remarks:
ORP= -47
MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)
WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88
TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
1314 1322
Dedicated BP PE
IDEAL TECH SERVICES, INC. GROUNDWATER SAMPLE LOG
Purging Data
Well Diameter
(inches):
Tubing
Diameter
(inches):
Static Depth to Water (ft):
Purge Pump
Type:
ITS Revision 1.0 Date: 11/06/19
Sample Preservation (including wet ice)
8011 EDB
App I Metals w/ Fe, Na, Hg
8260 App I VOC
Total Volume Added In Field
None
None
None
None
None
Sample Flow
Rate (milliliters per minute)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 oC Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);
optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater)
Dedicated BP Dedicated BP 1304 1314 2.50
NTU at metals sample = 7.3
Sample Container Specifications
SAMPLING DATA
Intended Analysis and/or Method Sampling
Equipment Code
Nitrate, Cl, TDS
Nitrogen, Ammonia
YES NO
YES NOYES YESNO NO
Site Name: Marion County Solid Waste Baseline landfill WACS ID: 20906 Site Location: Marion County, Florida
Well No: MW-5A WACS Well Number: 12859 Date: 2/18/25
Well Screen Interval (ft): NGVD
2 0.375 33 to 43 32.74 SS ESP
Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)
= ( 42.28 Feet - 32.74 Feet) * 0.16 Gallons/Ft= 1.53 Gallons
Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)
Gallons + ( 0.006 Gallons/Ft * 60 Feet) + 0.032 FCV = 0.392 Gallons
Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):
In Well (ft): In Well (ft):
Time
Volume
Purged
(gallons)
Total
Volume
Purged
(gallons)
Purge
Rate
(gpm)
Depth to
Water
(feet) pH
(standard units)
Temp
(°C)
COND
(µS/cm)
Dissolved
Oxygen
(mg/L)
Turbidity
(NTUs)
COLOR
(describe)
ODOR
(describe)
0948 1.50 1.50 0.30 32.85 6.34 24.6 993 0.09 1.10 none none
0950 0.60 2.10 0.30 32.85 6.34 24.6 993 0.08 1.00 none none
0952 0.60 2.70 0.30 32.85 6.33 24.6 993 0.07 1.20 none none
Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:
Chris Monaco
Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:
Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)
Field Decontamination Pump: Tubing Replaced: Duplicate:
Sample ID Code # Containers Material Code Volume Preservative Final pH
MW-5A 1 PE 1 L 6°C Not Required SS ESP 1136
MW-5A 1 PE 250 mL H₂SO₄ <2 SS ESP 1136
MW-5A 2 CG 40 mL 6°C Not Required SS ESP 100
MW-5A 1 PE 250 mL HNO₃ <2 SS ESP 1136
MW-5A 3 CG 40 mL HCl Not Required SS ESP 100
Remarks:
ORP= -114
MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)
WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88
TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
0952 0957
33.50 PE
IDEAL TECH SERVICES, INC. GROUNDWATER SAMPLE LOG
Purging Data
Well Diameter
(inches):
Tubing
Diameter
(inches):
Static Depth to Water (ft):
Purge Pump
Type:
ITS Revision 1.0 Date: 11/06/19
Sample Preservation (including wet ice)
8011 EDB
App I Metals w/ Fe, Na, Hg
8260 App I VOC
Total Volume Added In Field
None
None
None
None
None
Sample Flow
Rate (milliliters per minute)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 oC Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);
optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater)
33.50 33.50 0943 0952 2.70
Sample Container Specifications
SAMPLING DATA
Intended Analysis and/or Method Sampling
Equipment Code
Nitrate, Cl, TDS
Nitrogen, Ammonia
Site Name: Marion County Solid Waste Baseline landfill WACS ID: 20906 Site Location: Marion County, Florida
Well No: MW-6 WACS Well Number: 12829 Date: 2/18/25
Well Screen Interval (ft): NGVD
2 0.375 37 to 47 30.90 BP
Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)
= ( 46.92 Feet - 30.90 Feet) * 0.16 Gallons/Ft= 2.56 Gallons
Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)
Gallons + ( 0.006 Gallons/Ft * 50 Feet) + 0.032 FCV = 0.332 Gallons
Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):
In Well (ft): In Well (ft):
Time
Volume
Purged
(gallons)
Total
Volume
Purged
(gallons)
Purge
Rate
(gpm)
Depth to
Water
(feet) pH
(standard units)
Temp
(°C)
COND
(µS/cm)
Dissolved
Oxygen
(mg/L)
Turbidity
(NTUs)
COLOR
(describe)
ODOR
(describe)
1153 1.50 1.50 0.30 31.12 7.03 24.7 379 0.12 5.40 none none
1155 0.60 2.10 0.30 31.12 7.01 24.7 377 0.12 2.10 none none
1157 0.60 2.70 0.30 31.12 6.97 24.7 374 0.11 1.90 none none
Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:
Chris Monaco
Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:
Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)
Field Decontamination Pump: Tubing Replaced: Duplicate:
Sample ID Code # Containers Material Code Volume Preservative Final pH
MW-6 1 PE 1 L 6°C Not Required BP 1136
MW-6 1 PE 250 mL H₂SO₄ <2 BP 1136
MW-6 2 CG 40 mL 6°C Not Required BP 100
MW-6 1 PE 250 mL HNO₃ <2 BP 1136
MW-6 3 CG 40 mL HCl Not Required BP 100
Remarks:
ORP= -72
MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)
WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88
TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 oC Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);
optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater)
Dedicated BP Dedicated BP 1148 1157 2.70
Sample Container Specifications
SAMPLING DATA
Intended Analysis and/or Method Sampling
Equipment Code
Nitrate, Cl, TDS
Nitrogen, Ammonia
ITS Revision 1.0 Date: 11/06/19
Sample Preservation (including wet ice)
8011 EDB
App I Metals w/ Fe, Na, Hg
8260 App I VOC
Total Volume Added In Field
None
None
None
None
None
Sample Flow
Rate (milliliters per minute)
IDEAL TECH SERVICES, INC. GROUNDWATER SAMPLE LOG
Purging Data
Well Diameter
(inches):
Tubing
Diameter
(inches):
Static Depth to Water (ft):
Purge Pump
Type:
1157 1203
Dedicated BP PE
Site Name: Marion County Solid Waste Baseline landfill WACS ID: 20906 Site Location: Marion County, Florida
Well No: MW-7 WACS Well Number: 12829 Date: 2/17/25
Well Screen Interval (ft): NGVD
2 0.375 34 to 44 36.46 SS ESP
Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)
= ( 48.40 Feet - 36.46 Feet) * 0.16 Gallons/Ft= 1.91 Gallons
Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)
Gallons + ( 0.006 Gallons/Ft * 45 Feet) + 0.032 FCV = 0.302 Gallons
Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):
In Well (ft): In Well (ft):
Time
Volume
Purged
(gallons)
Total
Volume
Purged
(gallons)
Purge
Rate
(gpm)
Depth to
Water
(feet) pH
(standard units)
Temp
(°C)
COND
(µS/cm)
Dissolved
Oxygen
(mg/L)
Turbidity
(NTUs)
COLOR
(describe)
ODOR
(describe)
1511 2.10 2.10 0.30 36.54 6.54 25.1 486 0.61 4.10 none none
1513 0.60 2.70 0.30 36.54 6.55 25.1 491 0.65 1.70 none none
1515 0.60 3.30 0.30 36.54 6.54 25.1 494 0.57 1.10 none none
Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:
Chris Monaco
Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:
Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)
Field Decontamination Pump: Tubing Replaced: Duplicate:
Sample ID Code # Containers Material Code Volume Preservative Final pH
MW-7 1 PE 1 L 6°C Not Required SS ESP 1136
MW-7 1 PE 250 mL H₂SO₄ <2 SS ESP 1136
MW-7 2 CG 40 mL 6°C Not Required SS ESP 100
MW-7 1 PE 250 mL HNO₃ <2 SS ESP 1136
MW-7 3 CG 40 mL HCl Not Required SS ESP 100
Remarks:
ORP= 104
MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)
WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88
TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
37.50 PE
IDEAL TECH SERVICES, INC. GROUNDWATER SAMPLE LOG
Purging Data
Well Diameter
(inches):
Tubing
Diameter
(inches):
Static Depth to Water (ft):
Purge Pump
Type:
ITS Revision 1.0 Date: 11/06/19
Sample Preservation (including wet ice)
8011 EDB
App I Metals w/ Fe, Na, Hg
8260 App I VOC
Total Volume Added In Field
None
None
None
None
None
Sample Flow
Rate (milliliters per minute)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 oC Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);
optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater)
37.50 37.50 1504 1515 3.30
Sample Container Specifications
SAMPLING DATA
Intended Analysis and/or Method Sampling
Equipment Code
Nitrate, Cl, TDS
Nitrogen, Ammonia
Site Name: Marion County Solid Waste Baseline landfill WACS ID: 20906 Site Location: Marion County, Florida
Well No: MW-8D WACS Well Number: 12819 Date: 2/17/25
Well Screen Interval (ft): NGVD
2 0.375 48 to 58 46.90 SS ESP
Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)
= ( 71.14 Feet - 46.90 Feet) * 0.16 Gallons/Ft= 3.88 Gallons
Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)
Gallons + ( 0.006 Gallons/Ft * Feet) + 0.032 FCV = 0.032 Gallons
Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):
In Well (ft): In Well (ft):
Time
Volume
Purged
(gallons)
Total
Volume
Purged
(gallons)
Purge
Rate
(gpm)
Depth to
Water
(feet) pH
(standard units)
Temp
(°C)
COND
(µS/cm)
Dissolved
Oxygen
(mg/L)
Turbidity
(NTUs)
COLOR
(describe)
ODOR
(describe)
1425 4.00 4.00 0.40 47.18 6.36 26.9 1,070 0.07 0.60 Brown none
1428 1.20 5.20 0.40 47.18 6.37 26.9 1,069 0.07 0.80 Brown none
1431 1.20 6.40 0.40 47.18 6.38 26.9 1,060 0.07 1.30 Brown none
Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:
Chris Monaco
Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:
Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)
Field Decontamination Pump: Tubing Replaced: Duplicate:
Sample ID Code # Containers Material Code Volume Preservative Final pH
MW-8D 2 PE 1 L 6°C Not Required SS ESP 1136
MW-8D 2 PE 250 mL H₂SO₄ <2 / <2 SS ESP 1136
MW-8D 4 CG 40 mL 6°C Not Required SS ESP 100
MW-8D 2 PE 250 mL HNO₃ <2 / <2 SS ESP 1136
MW-8D 6 CG 40 mL HCl Not Required SS ESP 100
Sample/DUP
Remarks:
ORP= -110
MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)
WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88
TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
1431 1442
48.00 PE
IDEAL TECH SERVICES, INC. GROUNDWATER SAMPLE LOG
Purging Data
Well Diameter
(inches):
Tubing
Diameter
(inches):
Static Depth to Water (ft):
Purge Pump
Type:
ITS Revision 1.0 Date: 11/06/19
Sample Preservation (including wet ice)
8011 EDB
App I Metals w/ Fe, Na, Hg
8260 App I VOC
Total Volume Added In Field
None
None
None
None
None
Sample Flow
Rate (milliliters per minute)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 oC Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);
optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater)
48.00 48.00 1415 1431 6.40 cloudy tan sheen on purge water.
Sample Container Specifications
SAMPLING DATA
Intended Analysis and/or Method Sampling
Equipment Code
Nitrate, Cl, TDS
Nitrogen, Ammonia
Site Name: Marion County Solid Waste Baseline landfill WACS ID: 20906 Site Location: Marion County, Florida
Well No: MW-9 WACS Well Number: 12812 Date: 2/18/25
Well Screen Interval (ft): NGVD
2 0.375 53 to 63 45.64 BP
Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)
= ( 61.47 Feet - 45.64 Feet) * 0.16 Gallons/Ft= 2.53 Gallons
Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)
Gallons + ( 0.006 Gallons/Ft * 65 Feet) + 0.032 FCV = 0.422 Gallons
Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):
In Well (ft): In Well (ft):
Time
Volume
Purged
(gallons)
Total
Volume
Purged
(gallons)
Purge
Rate
(gpm)
Depth to
Water
(feet) pH
(standard units)
Temp
(°C)
COND
(µS/cm)
Dissolved
Oxygen
(mg/L)
Turbidity
(NTUs)
COLOR
(describe)
ODOR
(describe)
1347 1.20 1.20 0.30 45.87 6.42 24.7 907 0.29 5.20 none none
1349 0.60 1.80 0.30 45.87 6.43 24.7 907 0.27 3.60 none none
1351 0.60 2.40 0.30 45.87 6.43 24.6 908 0.25 3.40 none none
Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:
Chris Monaco
Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:
Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)
Field Decontamination Pump: Tubing Replaced: Duplicate:
Sample ID Code # Containers Material Code Volume Preservative Final pH
MW-9 1 PE 1 L 6°C Not Required BP 1136
MW-9 1 PE 250 mL H₂SO₄ <2 BP 1136
MW-9 2 CG 40 mL 6°C Not Required BP 100
MW-9 1 PE 250 mL HNO₃ <2 BP 1136
MW-9 3 CG 40 mL HCl Not Required BP 100
Remarks:
ORP= 71
MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)
WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88
TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 oC Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);
optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater)
Dedicated BP Dedicated BP 1343 1351 2.40
Sample Container Specifications
SAMPLING DATA
Intended Analysis and/or Method Sampling
Equipment Code
Nitrate, Cl, TDS
Nitrogen, Ammonia
ITS Revision 1.0 Date: 11/06/19
Sample Preservation (including wet ice)
8011 EDB
App I Metals w/ Fe, Na, Hg
8260 App I VOC
Total Volume Added In Field
None
None
None
None
None
Sample Flow
Rate (milliliters per minute)
IDEAL TECH SERVICES, INC. GROUNDWATER SAMPLE LOG
Purging Data
Well Diameter
(inches):
Tubing
Diameter
(inches):
Static Depth to Water (ft):
Purge Pump
Type:
1351 1359
Dedicated BP PE
Site Name: Marion County Solid Waste Baseline landfill WACS ID: 20906 Site Location: Marion County, Florida
Well No: MW-11 WACS Well Number: 12831 Date: 2/19/25
Well Screen Interval (ft): NGVD
2 0.375 54 to 64 47.10 BP
Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)
= ( 71.49 Feet - 47.10 Feet) * 0.16 Gallons/Ft= 3.90 Gallons
Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)
Gallons + ( 0.006 Gallons/Ft * 66 Feet) + 0.032 FCV = 0.428 Gallons
Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):
In Well (ft): In Well (ft):
Time
Volume
Purged
(gallons)
Total
Volume
Purged
(gallons)
Purge
Rate
(gpm)
Depth to
Water
(feet) pH
(standard units)
Temp
(°C)
COND
(µS/cm)
Dissolved
Oxygen
(mg/L)
Turbidity
(NTUs)
COLOR
(describe)
ODOR
(describe)
1007 1.20 1.20 0.30 47.46 6.59 24.8 1,035 0.15 9.60 none none
1009 0.60 1.80 0.30 47.46 6.57 24.8 1,022 0.17 3.80 none none
1011 0.60 2.40 0.30 47.46 6.56 24.8 1,020 0.16 2.60 none none
Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:
Chris Monaco
Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:
Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)
Field Decontamination Pump: Tubing Replaced: Duplicate:
Sample ID Code # Containers Material Code Volume Preservative Final pH
MW-11 1 PE 1 L 6°C Not Required BP 1136
MW-11 1 PE 250 mL H₂SO₄ <2 BP 1136
MW-11 2 CG 40 mL 6°C Not Required BP 100
MW-11 1 PE 250 mL HNO₃ <2 BP 1136
MW-11 3 CG 40 mL HCl Not Required BP 100
Remarks:
ORP= 48
MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)
WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88
TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
1011 1017
Dedicated BP PE
Purging Data
Well Diameter
(inches):
Tubing
Diameter
(inches):
Static Depth to Water (ft):
Purge Pump
Type:
ITS Revision 1.0 Date: 11/06/19
Sample Preservation (including wet ice)
8011 EDB
App I Metals w/ Fe, Na, Hg
8260 App I VOC
Total Volume Added In Field
None
None
None
None
None
Sample Flow
Rate (milliliters per minute)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 oC Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);
optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater)
Dedicated BP Dedicated BP 1003 1011 2.40
Sample Container Specifications
SAMPLING DATA
Intended Analysis and/or Method Sampling
Equipment Code
Nitrate, Cl, TDS
Nitrogen, Ammonia
Site Name: Marion County Solid Waste Baseline landfill WACS ID: 20906 Site Location: Marion County, Florida
Well No: MW-12 WACS Well Number: 12832 Date: 2/18/25
Well Screen Interval (ft): NGVD
2 0.375 47 to 57 40.39 BP
Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)
= ( 57.22 Feet - 40.39 Feet) * 0.16 Gallons/Ft= 2.69 Gallons
Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)
Gallons + ( 0.006 Gallons/Ft * 60 Feet) + 0.032 FCV = 0.392 Gallons
Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):
In Well (ft): In Well (ft):
Time
Volume
Purged
(gallons)
Total
Volume
Purged
(gallons)
Purge
Rate
(gpm)
Depth to
Water
(feet) pH
(standard units)
Temp
(°C)
COND
(µS/cm)
Dissolved
Oxygen
(mg/L)
Turbidity
(NTUs)
COLOR
(describe)
ODOR
(describe)
1227 1.00 1.00 0.20 40.72 6.53 25.0 773 0.29 19.90 none none
1229 0.40 1.40 0.20 40.72 6.53 25.0 773 0.28 17.60 none none
1231 0.40 1.80 0.20 40.72 6.53 25.0 771 0.32 13.20 none none
Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:
Chris Monaco
Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:
Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)
Field Decontamination Pump: Tubing Replaced: Duplicate:
Sample ID Code # Containers Material Code Volume Preservative Final pH
MW-12 1 PE 1 L 6°C Not Required BP 757
MW-12 1 PE 250 mL H₂SO₄ <2 BP 757
MW-12 2 CG 40 mL 6°C Not Required BP 100
MW-12 1 PE 250 mL HNO₃ <2 BP 757
MW-12 3 CG 40 mL HCl Not Required BP 100
Remarks:
ORP= 100
MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)
WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88
TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 oC Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);
optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater)
Dedicated BP Dedicated BP 1222 1231 1.80
Purge starts orange then clears. NTU at metals sample = 5.5
Sample Container Specifications
SAMPLING DATA
Intended Analysis and/or Method Sampling
Equipment Code
Nitrate, Cl, TDS
Nitrogen, Ammonia
ITS Revision 1.0 Date: 11/06/19
Sample Preservation (including wet ice)
8011 EDB
App I Metals w/ Fe, Na, Hg
8260 App I VOC
Total Volume Added In Field
None
None
None
None
None
Sample Flow
Rate (milliliters per minute)
IDEAL TECH SERVICES, INC. GROUNDWATER SAMPLE LOG
Purging Data
Well Diameter
(inches):
Tubing
Diameter
(inches):
Static Depth to Water (ft):
Purge Pump
Type:
1231 1239
Dedicated BP PE
Site Name: Marion County Solid Waste Baseline landfill WACS ID: 20906 Site Location: Marion County, Florida
Well No: MW-13 WACS Well Number: 12833 Date: 2/18/25
Well Screen Interval (ft): NGVD
2 0.375 60 to 70 31.16 BP
Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)
= ( 70.10 Feet - 31.16 Feet) * 0.16 Gallons/Ft= 6.23 Gallons
Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)
Gallons + ( 0.006 Gallons/Ft * 70 Feet) + 0.032 FCV = 0.452 Gallons
Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):
In Well (ft): In Well (ft):
Time
Volume
Purged
(gallons)
Total
Volume
Purged
(gallons)
Purge
Rate
(gpm)
Depth to
Water
(feet) pH
(standard units)
Temp
(°C)
COND
(µS/cm)
Dissolved
Oxygen
(mg/L)
Turbidity
(NTUs)
COLOR
(describe)
ODOR
(describe)
1442 1.20 1.20 0.30 32.21 4.73 24.2 71 4.64 0.90 none none
1444 0.60 1.80 0.30 32.21 4.72 24.2 70 4.63 0.60 none none
1446 0.60 2.40 0.30 32.21 4.71 24.2 69 4.62 0.90 none none
Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:
Chris Monaco
Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:
Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)
Field Decontamination Pump: Tubing Replaced: Duplicate:
Sample ID Code # Containers Material Code Volume Preservative Final pH
MW-13 1 PE 1 L 6°C Not Required BP 1136
MW-13 1 PE 250 mL H₂SO₄ <2 BP 1136
MW-13 2 CG 40 mL 6°C Not Required BP 100
MW-13 1 PE 250 mL HNO₃ <2 BP 1136
MW-13 3 CG 40 mL HCl Not Required BP 100
Remarks:
ORP= 247
MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)
WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88
TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 oC Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);
optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater)
Dedicated BP Dedicated BP 1438 1446 2.40
Sample Container Specifications
SAMPLING DATA
Intended Analysis and/or Method Sampling
Equipment Code
Nitrate, Cl, TDS
Nitrogen, Ammonia
ITS Revision 1.0 Date: 11/06/19
Sample Preservation (including wet ice)
8011 EDB
App I Metals w/ Fe, Na, Hg
8260 App I VOC
Total Volume Added In Field
None
None
None
None
None
Sample Flow
Rate (milliliters per minute)
IDEAL TECH SERVICES, INC. GROUNDWATER SAMPLE LOG
Purging Data
Well Diameter
(inches):
Tubing
Diameter
(inches):
Static Depth to Water (ft):
Purge Pump
Type:
1446 1452
Dedicated BP PE
Site Name: Marion County Solid Waste Baseline landfill WACS ID: 20906 Site Location: Marion County, Florida
Well No: MW-14 WACS Well Number: 12834 Date: 2/18/25
Well Screen Interval (ft): NGVD
2 0.375 100 to 110 36.63 SS ESP
Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)
= ( 108.30 Feet - 36.63 Feet) * 0.16 Gallons/Ft= 11.47 Gallons
Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)
Gallons + ( 0.006 Gallons/Ft * 110 Feet) + 0.032 FCV = 0.692 Gallons
Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):
In Well (ft): In Well (ft):
Time
Volume
Purged
(gallons)
Total
Volume
Purged
(gallons)
Purge
Rate
(gpm)
Depth to
Water
(feet) pH
(standard units)
Temp
(°C)
COND
(µS/cm)
Dissolved
Oxygen
(mg/L)
Turbidity
(NTUs)
COLOR
(describe)
ODOR
(describe)
1023 1.20 1.20 0.30 37.23 6.12 25.3 400 0.11 1.20 yellow none
1025 0.60 1.80 0.30 37.23 6.15 25.3 413 0.10 1.00 yellow none
1027 0.60 2.40 0.30 37.23 6.20 25.3 414 0.10 1.10 yellow none
Sampled By: Ideal Tech Services, Inc. Signature: Sampling Initiated At: Sampling Ended At:
Chris Monaco
Pump or Tubing Depth in Tubing Material Field Filtered: Filter Size:
Well (ft): Code: Filtration Equipment Type: polyethersulphone (mm)
Field Decontamination Pump: Tubing Replaced: Duplicate:
Sample ID Code # Containers Material Code Volume Preservative Final pH
MW-14 1 PE 1 L 6°C Not Required SS ESP 1136
MW-14 1 PE 250 mL H₂SO₄ <2 SS ESP 1136
MW-14 2 CG 40 mL 6°C Not Required SS ESP 100
MW-14 1 PE 250 mL HNO₃ <2 SS ESP 1136
MW-14 3 CG 40 mL HCl Not Required SS ESP 100
Remarks:
ORP= -68
MATERIAL CODES: AG = Amber Glass; CG = Clear Glass; HDPE = High Density Polyethylene; LDPE = Low Density Polyethylene; PP = Polypropylene; S = Silicone; T = Teflon; O = Other (Specify)
SAMPLING EQUIPMENT CODES: APP = After (Through) Peristaltic Pump; B = Bailer; BP = Bladder Pump; ESP = Electric Submersible Pump;
SS ESP = Stainless Steel Electric Submersible Pump; RFPP = Reverse Flow Peristaltic Pump; SM = Straw Method (Tubing Gravity Drain); O = Other (Specify)
WELL CAPACITY (Gallons Per Foot): 0.75” = 0.02; 1” = 0.04; 1.25” = 0.06; 2” = 0.16; 3” = 0.37; 4” = 0.65; 5” = 1.02; 6” = 1.47; 12” = 5.88
TUBING INSIDE DIA. CAPACITY (Gal./Ft.): 1/8" = 0.0006; 3/16" = 0.0014; 1/4" = 0.0026; 5/16" = 0.004; 3/8" = 0.006; 1/2" = 0.010; 5/8" = 0.016
1027 1033
105.00 PE
IDEAL TECH SERVICES, INC. GROUNDWATER SAMPLE LOG
Purging Data
Well Diameter
(inches):
Tubing
Diameter
(inches):
Static Depth to Water (ft):
Purge Pump
Type:
ITS Revision 1.0 Date: 11/06/19
Sample Preservation (including wet ice)
8011 EDB
App I Metals w/ Fe, Na, Hg
8260 App I VOC
Total Volume Added In Field
None
None
None
None
None
Sample Flow
Rate (milliliters per minute)
NOTES: 1. The above do not constitute all of the information required by Chapter 62-160, F.A.C.
2. STABILIZATION CRITERIA FOR RANGE OF VARIATION OF LAST THREE CONSECUTIVE READINGS (SEE FS 2212, SECTION 3) pH: ± 0.2 units Temperature: ± 0.2 oC Specific Conductance: ± 5% Dissolved Oxygen: all readings ≤ 20% saturation (see Table FS 2200-2);
optionally, ± 0.2 mg/L or ± 10% (whichever is greater) Turbidity: all readings ≤ 20 NTU; optionally ± 5 NTU or ± 10% (whichever is greater)
105.00 105.00 1019 1027 2.40
Sample Container Specifications
SAMPLING DATA
Intended Analysis and/or Method Sampling
Equipment Code
Nitrate, Cl, TDS
Nitrogen, Ammonia
Site Name: Marion County Solid Waste Baseline landfill WACS ID: 20906 Site Location: Marion County, Florida
Well No: MW-15 WACS Well Number: 12862 Date: 2/19/25
Well Screen Interval (ft): NGVD
2 0.375 52 to 62 37.92 BP
Well Volume Purge: 1 Well Volume = (Total Well Depth - Static Depth To Water) * Well Capacity (gal/ft)
= ( 61.55 Feet - 37.92 Feet) * 0.16 Gallons/Ft= 3.78 Gallons
Equipment Volume Purge: 1 Equipment Vol. = Pump Volume + (Tubing Capacity * Tubing Length) + Flow Cell Volume (FCV)
Gallons + ( 0.006 Gallons/Ft * 62 Feet) + 0.032 FCV = 0.404 Gallons
Initial Pump or Tubing Depth Final Pump or Tubing Depth Purging Initiated At: Purging Ended At: Total Volume Purged (gal):
In Well (ft): In Well (ft):
Time
Volume
Purged
(gallons)
Total
Volume
Purged
(gallons)
Purge
Rate
(gpm)
Depth to
Water
(feet) pH