Document_B_-_Billings_Asbestos_Inspection.pdf

PDF 6 MB Posted

Attached to
Montana FOB/CH/PO Full Facilities Maintenance Services
Solicitation number
47PJ0018R0027
Issued by

About this file

Document C - Bozeman Asbestos Inspection (Drawings Removed)

View the file

Other files

File Type Posted
Amendment_0005_-_Q&As.pdf PDF
Amendment_0004_-_Additional_Questions_and_Answers.pdf PDF
Document_C_-_Bozeman_Asbestos_Inspection_(drawings_removed).pdf PDF
Amendment_0003_-_Correct_Deliverable_and_Submittal_Information.pdf PDF
Revised_-_Solicitation_Sections_A-M_-_Amendment_0003.pdf PDF
Document_G_-_Battin_dates_for_next_PMs.pdf PDF
Attachment_13_-_Pricing_Worksheet_-_OFFEROR_SHALL_VERIFY_TOTALS_ARE_CORRECT_-_Amendment_0002.xlsx XLSX spreadsheet
Document_I_-_Butte_dates_for_next_PMs.pdf PDF
Document_J_-_Missoula_dates_for_next_PMs.pdf PDF
Document_A_-_Site_Visit_Sign_in_Sheets.pdf PDF
Document_E_-_Missoula_Asbestos_Inspection_(drawings_removed).pdf PDF
Amendment_0002_-_Questions_and_Answers_with_Associated_Changes.pdf PDF
Document_D_-_Butte_Asbestos_Inspection_(drawings_removed).pdf PDF
Document_F_-_Excel_Equipment_List.xlsx XLSX spreadsheet
Document_H_-_Bozeman_dates_for_next_PMs.pdf PDF
Revised_-_Solicitation_Sections_A-M.pdf PDF
Attachment_14_-_Offeror_Experience_-_Amendment_0001.docx DOCX document
Amendment_0001_-_Solicitation_Changes.pdf PDF
Continuation_of_SF1449_-_Montana_FOB,_CH,_and_PO_Solicitation_-_Amendment_0001.pdf PDF
Attachment_10_-_Bozeman_FOB_and_PO_Boundary_for_Snow_Removal_and_Grounds_Maintenance.pdf PDF
Attachment_13_-_Pricing_Worksheet_-_OFFEROR_SHALL_VERIFY_TOTALS_ARE_CORRECT.xlsx XLSX spreadsheet
Attachment_14_-_Offeror_Experience.docx DOCX document
Solicitation_47PJ0018R0027.pdf PDF
Attachment_09_-_Billings_CH_Boundary_for_Snow_Removal_and_Grounds_Maintenance.pdf PDF
Attachment_01_-_Register_of_Wage_Determination_-_Collective_Bargaining_Agreement.pdf PDF
Attachment_11_-_Butte_FOB_and_CH_Boundary_for_Snow_Removal_and_Grounds_Maintennace.pdf PDF
Attachment_04_-_Secondary_Wage_Determination_2015-5399_Revision_5_dated_01.10.2018_-_Gallatin_and_Silver_Bow_County_-_Butte_and_Bozeman.pdf PDF
Attachment_12_-_Missoula_FOB_and_PO_Boundary_for_Snow_Removal_and_Gounds_Maintenance.pdf PDF
Attachment_07_-_Equipment_Inventory_List_-_Butte_FOB_and_CH,_dated_04.17.2018.pdf PDF
Attachment_05_-_Equipment_Inventory_List_-_Billings_CH,_dated_04.17.2018.pdf PDF
Attachment_06_-_Equipment_Inventory_List_-_Bozeman_FOB_and_PO,_dated_04.17.2018.pdf PDF
Attachment_15_-_Offeror_Past_Performance_Questionnaire.docx DOCX document
Attachment_03_-_Secondary_Wage_Determination_2015-5393_Revision_5_dated_01.10.2018_-_Missoula_County_-_Missoula_Builing.pdf PDF
Attachment_08_-_Equipment_Inventory_List_-_Missoula_FOB_and_PO,_dated_04.17.2018.pdf PDF
Attachment_02_-_Secondary_Wage_Determination_2015-5389_Revision_5_dated_01.10.2018_-_Yellowstone_County_-_Billings_Building.pdf PDF
2018.04.18_-_Site_Visit_Schedule_Change.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS INSPECTION REPORT

James F. Battin Federal Courthouse Billings, MT 59101

GSA Building No. MT0050 08/05/13

Prepared By:

10625 West I-70 Frontage Road North

Suite 3 Wheat Ridge, CO 80033

(303) 423-3300

GENERAL BUILDING and CONSULTANT INFORMATION

Client: General Services Administration

Facility Inspected: James F. Battin Federal Courthouse

Facility Address: 2601 2nd Ave. North

Client Telephone #: (406) 839-1930

Contact: Mike Buhman

Date of Survey: 08/05/2013

Consulting Firm Name: IHI Environmental

Consulting Firm Address: 10625 W. I-70 Frontage Rd. N.

Consulting Firm Telephone #: (303) 423-3300

Building Number: MT0050

Laboratory Address: Scientific Analytical Institute, Inc.

4604 Dundas Drive

Laboratory Telephone #: (336)292-3888

Brian Ramsell EPA Accredited Building Inspector State Accreditation No.: MTA-4278

Inspector's Signature:_______________________________________________

Reviewer's Signature:_______________________________________________ Brendan Hainsworth

Wheat Ridge, CO 80033

Greensboro, NC 27407

Date(s) of Construction: 2012

Portion of Building Inspected: 99%

Building Construction: steel frame and pre-cast panels

HVAC System: forced air

Total Building Square Footage

128,742 square feet

Billings, MT 59101

EPA Accredited Management Planner MTA-4258State Accreditation No.:

IHI Environmental

TABLE OF CONTENTS

EXECUTIVE SUMMARY

SECTION 1: INTRODUCTION AND SCOPE OF WORK

SECTION 2: INSPECTION PROCEDURES

SECTION 3: SURVEY FINDINGS

SECTION 4: CONCLUSIONS AND RECOMMENDATIONS

SECTION 6: LIMITATIONS

APPENDICES

APPENDIX A - FIGURES

Figure Set 1 - ACBM Sample and Photograph Locations Figure Set 2 - ACBM Material Locations

APPENDIX B - TABLES

Table 1 - Summary of Confirmed Asbestos-Containing Materials and Recommended Response Actions Table 2 - Summary of Materials Confirmed Not to Contain Asbestos Table 3 - Bulk Sample Analysis Results

APPENDIX C - LABORATORY ANALYSIS REPORT AND CHAIN OF CUSTODY

APPENDIX D - PHOTOGRAPHS

APPENDIX E - ABATEMENT DOCUMENTS

APPENDIX F - GENERAL INSPECTION INFORMATION

Asbestos Overview Sample Collection Requirements AHERA Assessment Categories for Friable ACBM Required Response Actions Based on AHERA Assessment Categories Material Category List Glossary

APPENDIX G - INSPECTOR CERTIFICATES

SECTION 5: REMOVAL COST ESTIMATE

Inspection and Sampling Laboratory Analysis Quality Assurance and Quality Control

Building Description Findings

Room-By-Room Table Key Table C - Implementation Table of Abatement Prioritization by Material Condition

Conclusions Recommendations

Table A - Functional Space Summary Table B - Room-By-Room Summary of Suspect and Confirmed ACBM's

IHI Environmental

EXECUTIVE SUMMARY

IHI Environmental was retained by General Services Administration to perform asbestos reinspection services of the James F. Battin Federal Courthouse, located at 2601 2nd Ave.

North in Billings, MT 59101.

The building was constructed in 2012. The facility inspected is a 5-story steel frame and pre-cast panels structure with basement garage. It encompasses a total of 128,742 square feet of building space.

Asbestos Findings

The James F. Battin Building has a structural framework consisting of steel columns and I-beams. The exterior of the building, including the west facing formal colonnade and classic portico, are finished with stone veneer faced pre-cast concrete panels. The roof consists of corrugated metal decking overlaid with a thermoplastic membrane roof and the west roof of the building includes a garden terrace. The building is comprised of court rooms, holding cells, office space, restrooms, a mechanical penthouse, mechanical rooms, storage space and a subterranean parking garage.

The building’s interior contains a variety of building materials. Flooring materials include terrazzo, resilient vinyl floor tiles and/or carpeting in the halls and common areas, ceramic tiles, in the restrooms, carpeting, resilient floor tile and/or vinyl sheet flooring in the office spaces and work-rooms, and bare concrete floors in the mechanical rooms. Wall materials in the building include bare concrete, CMU block, ceramic tile, wood paneling, stone veneer paneling, and/or gypsum wallboard systems and most are generally associated with vinyl cove base. Ceilings in the structure include metal corrugated decks, bare concrete, suspended ceiling tiles, and/or gypsum wallboard.

The heating and cooling is supplied by a forced air heating, ventilation and air-conditioning (HVAC) system with air handing units located in the mechanical penthouse and mechanical spaces located on first floor and in the basement. The air handling unit main ductwork part of this system is covered outside with fiberglass insulation. Branch ductwork servicing individual vents are insulated with fiberglass. The interior of the ductwork was inaccessible at the time of the inspection, due to usage. Circulatory system and domestic hot water piping were insulated with fiberglass on straight runs and fittings. Pipe gaskets were found to be inaccessible; system shut-down and/or removal of insulation would have been necessary to disassemble flanges for access to obtain samples of the pipe gaskets. Pipe gaskets were assumed to contain asbestos.

Miscellaneous materials such as ceramic tile grout, ceramic tile adhesive, sink undercoats, fire door insulation, elevator brake shoes, and roofing materials were also observed in and on the building. Ceramic tile grout, ceramic tile adhesive, fire door insulation, elevator brake shoes, and roofing materials (to preserve the integrity of the roof seal) were not sampled and are assumed to contain asbestos.

There exists the potential for adhesives to be present behind wood, stone, metal, polymer and fabric covered panels affixed to the walls. Should adhesive(s) be encountered during the removal of any of these panels, the adhesive(s) should be treated as an assumed asbestos containing material until it can be proven otherwise by a State of Montana certified asbestos building inspector.

Abatement History

Nearly new building. No significant renovations and/or associated abatements performed to date.

IHI Environmental 1

IHI Environmental conducted an asbestos reinspection at the James F. Battin Federal Courthouse on 8/5/2013. Materials assumed to contain asbestos were not sampled to protect structural integrity. The following suspect homogeneous materials were confirmed or assumed to contain asbestos:

Recommendations Based on the results of laboratory analysis of bulk samples and visual and tactile assessment of building materials confirmed to contain asbestos, IHI recommends the following specific management actions:

Material Description Material Number and Additional Comments Management

Recommendations M1.1 - Roofing Materials, Assumed ACM O&MRoofing Materials

M16.19 - Elevator Brake Shoes, Assumed ACM O&MOther

M16.2 - Ceramic Tile Grout and Adhesive, Assumed ACM

O&MOther

M9.1 - Fire Door Insulation, Assumed ACM O&MFire Door Insulation

Material Description Material Number and Additional Comments M1.1 - Roofing Materials, Assumed ACMRoofing Materials

M16.19 - Elevator Brake Shoes, Assumed ACMOther

M16.2 - Ceramic Tile Grout and Adhesive, Assumed ACMOther

M9.1 - Fire Door Insulation, Assumed ACMFire Door Insulation

IHI Environmental 2

SECTION 1: INTRODUCTION AND SCOPE OF WORK

IHI Environmental was retained by General Services Administration to perform a re-inspection asbestos survey of the James F. Battin Federal Courthouse located at 2601 2nd Ave. North, in Billings, MT. The purpose of this survey was to identify friable and nonfriable suspect asbestos-containing building materials (ACBM).

The scope of this inspection included the following activities:

• Surveying, identifying, and sampling suspect friable and non-friable ACBM.

• Preparing this comprehensive report documenting the sampling procedures and results of the ACBM survey.

To accomplish this survey, all accessible areas of the building were identified by name and a room number assigned. A summary of identified functional spaces is presented in Table A.

Within each space, suspect building materials were identified. IHI uses a standardized numbering format to identify suspect building materials, and to identify bulk samples. A comprehensive list of this standardized numbering format is described in the Material Summary List found in Appendix F.

IHI Environmental 3

SECTION 2: INSPECTION PROCEDURES

The asbestos survey was performed using the applicable portions of the currently recognized standard protocol developed for schools under AHERA, as promulgated in Title 40, Code of Federal Regulations (40 CFR), Part 763 and as amended in the Federal Register. Since the primary concern for this investigation was to identify potential asbestos hazards in the entire building, IHI representatives visually inspected existing conditions within the entire facility. An overview of asbestos and current regulations and a glossary of common terms is presented inAppendix F - General Inspection Information.

Inspection and Sampling

The inspection was conducted by our accredited inspectors, and consisted of a detailed visual survey of surfacing materials, thermal system insulation, and miscellaneous materials throughout the building. Suspect ACBM was then grouped into homogeneous materials and sampling plans developed. Components of the inspection included:

• Identification of homogeneous suspect materials on a room by room basis. A summary of the suspect materials identified and all bulk sample analysis results is presented in Appendix B - Tables. Locations of bulk samples confirmed ACBM (if any) is shown in Appendix A - Figures.

• An assessment of known or assumed ACBM, generally classifying the materials using categories defined in the AHERA and National Emission Standards of Hazardous Air Pollutants (NESHAP), for asbestos. AHERA assessment categories are summarized in Appendix F. A description of NESHAP categories is presented in the Section 3 Room-By-Room Table Key.

• Homogeneous suspect ACBM's were, for the purposes of this study, placed into the following four material type categories: thermal system insulation (TSI), surfacing materials, miscellaneous materials, and floor covering. AHERA sampling protocol specifies sampling procedures for each material type.

A description of the AHERA sampling protocol is summarized in Appendix F.

Sample locations for this survey were chosen in a non-random fashion, with emphasis placed on obtaining samples of each type of accessible, suspect material and minimizing damage to the material being sampled. Samples were collected by carefully removing small portions of the suspect material in a non-abrasive manner. If possible, samples from existing damaged areas or loose pieces of material were collected. Immediately after collection, samples were placed in pre-labeled plastic containers. Containers with samples were then placed in a large resealable plastic bag for transportation to the laboratory. Sample locations are shown on Figure Set 1, Appendix A.

Samples were obtained by using techniques such as wet slicing, wet boring or similar methods designed to limit contamination of the area during sampling. The sampled area was sealed using patching compounds, duct tape, or spray encapsulates as appropriate to the material being sampled.

Photographs of each suspect ACBM were taken during the inspection. Photographs of confirmed or assumed ACBM are presented in Appendix D.

IHI Environmental 4

Laboratory Analysis

Bulk samples obtained during the inspection were assigned bulk sample numbers and entered on sample summary/chain-of-custody forms. The samples were transported to the laboratory by overnight courier under standard chain-of-custody procedures. The analysis was performed in accordance with EPA Interim Method 600/M4-82-020 and 600/R-93-116, July 1993, which employ polarized light microscopic techniques with dispersion staining for identification of mineral forms of asbestos. The quantification of asbestos in the sample is intended to be an estimate only and the limit of detection for this method is approximately 1% by volume.

Sample analysis results are presented in Appendix C - Laboratory Analysis Report and Chain of Custody.

Quality Assurance and Quality Control

Quality Assurance and quality control (QA/QC) measures adopted by IHI involved field and office components. Key parameters are summarized below:

Field QA/QC

• Review inspection forms for completeness;

• Check Homogeneous Materials Listing for sufficient number of collected samples;

• Verify locations of major mechanical components;

Office QA/QC

• Review lab results for completeness;

• Ensure appropriate cross-referencing of results, forms for given ACBM;

• Ensure drawings are updated as necessary following field QC;

• Verify approximate quantities of ACBM based on drawing review;

• Review recorded field comments for meaning, incorporate as necessary into report.

IHI Environmental 5

SECTION 3: SURVEY FINDINGS

The James F. Battin Federal Courthouse was constructed in 2012. The facility is a 5-story steel frame and pre-cast panels structure with basement garage. It encompasses a total of 128,742 square feet of building space.

The James F. Battin Building has a structural framework consisting of steel columns and I-beams. The exterior of the building, including the west facing formal colonnade and classic portico, are finished with stone veneer faced pre-cast concrete panels. The roof consists of corrugated metal decking overlaid with a thermoplastic membrane roof and the west roof of the building includes a garden terrace. The building is comprised of court rooms, holding cells, office space, restrooms, a mechanical penthouse, mechanical rooms, storage space and a subterranean parking garage.

The building’s interior contains a variety of building materials. Flooring materials include terrazzo, resilient vinyl floor tiles and/or carpeting in the halls and common areas, ceramic tiles, in the restrooms, carpeting, resilient floor tile and/or vinyl sheet flooring in the office spaces and work-rooms, and bare concrete floors in the mechanical rooms. Wall materials in the building include bare concrete, CMU block, ceramic tile, wood paneling, stone veneer paneling, and/or gypsum wallboard systems and most are generally associated with vinyl cove base. Ceilings in the structure include metal corrugated decks, bare concrete, suspended ceiling tiles, and/or gypsum wallboard.

The heating and cooling is supplied by a forced air heating, ventilation and air-conditioning (HVAC) system with air handing units located in the mechanical penthouse and mechanical spaces located on first floor and in the basement. The air handling unit main ductwork part of this system is covered outside with fiberglass insulation. Branch ductwork servicing individual vents are insulated with fiberglass. The interior of the ductwork was inaccessible at the time of the inspection, due to usage. Circulatory system and domestic hot water piping were insulated with fiberglass on straight runs and fittings. Pipe gaskets were found to be inaccessible; system shut-down and/or removal of insulation would have been necessary to disassemble flanges for access to obtain samples of the pipe gaskets. Pipe gaskets were assumed to contain asbestos.

Miscellaneous materials such as ceramic tile grout, ceramic tile adhesive, sink undercoats, fire door insulation, elevator brake shoes, and roofing materials were also observed in and on the building. Ceramic tile grout, ceramic tile adhesive, fire door insulation, elevator brake shoes, and roofing materials (to preserve the integrity of the roof seal) were not sampled and are assumed to contain asbestos.

There exists the potential for adhesives to be present behind wood, stone, metal, polymer and fabric covered panels affixed to the walls. Should adhesive(s) be encountered during the removal of any of these panels, the adhesive(s) should be treated as an assumed asbestos containing material until it can be proven otherwise by a State of Montana certified asbestos building inspector.

Nearly new building. No significant renovations and/or associated abatements performed to date.

Building Description

Findings

IHI identified suspect homogeneous materials within the building. Of these and including the

Table A summarizes each room by floor, room number, description of the functional space, and additional comments as necessary.

Abatement History

IHI Environmental 6

Table B provides a Room-by-Room summary of identified suspect and confirmed asbestos containing building materials (ACBM). A Room-By-Room Table Key is provided at the end of this section to provide explanative information for the column headings found in Table B. Locations of confirmed ACBM's are shown on Figure Set 2, Appendix A. Confirmed asbestos and non-asbestos containing materials are displayed in Table 1 and Table 2 in Appendix B. Bulk sample results are presented in Table 3, Appendix B.

results of the previous inspections, asbestos was confirmed or assumed to be present in quantities greater than 1% in the following materials:

Material Description Material Number and Additional Comments M1.1 - Roofing Materials, Assumed ACMRoofing Materials

M16.19 - Elevator Brake Shoes, Assumed ACMOther

M16.2 - Ceramic Tile Grout and Adhesive, Assumed ACMOther

M9.1 - Fire Door Insulation, Assumed ACMFire Door Insulation

IHI Environmental 7

TABLE A: Functional Space Summary

Floor: Room: Comments:Desc of Functional Space:

1000 ENTRANCES AND EXIT AREAS Entry Vestibule1 1001 OTHER Security Queuing1 1002 OTHER Lobby Security1

1002B OTHER Locker1 1003 OTHER Fire Command Room1 1101 LOBBIES Main Building/Elevator lobby1

1101A HALLWAYS Vestibule to Probation Reception1 1101B HALLWAYS West side, South Vestibule1 1102 STAIRWELLS Stairwell #31 1103 STAIRWELLS Stairwell #11 1104 STAIRWELLS Stairwell #21 1105 RESTROOM Women's Restroom1 1106 RESTROOM Men's Restroom1 1107 JANITOR CLOSET Custodial Room1 1201 OFFICES Office1 1202 OFFICES Office1 1203 MEETING ROOMS Computer Training1 1204 OFFICES Office1 1205 WORK-ROOM Work Room1

1205B WORK-ROOM Work Room1 1205C OFFICES Open Office1 1205I HALLWAYS East End, South Corridor1 1205J HALLWAYS East End, East of Judges Elevator1 1206 STORAGE Bulk Storage1 1207 RESTROOM Staff Toilet, North1 1208 RESTROOM Staff Toilet, South1 1210 OFFICES Office1 1211 STORAGE Storage1 1212 OFFICES Office1 1213 VAULTS Vault1 1214 OFFICES Office1 1215 MEETING ROOMS Conference Room1 1216 OTHER Break Room1 1217 OFFICES Office1

1217A OFFICES Office1 1217B COMPUTER ROOM Joint Server Room1 1218 VAULTS Vault1 1219 TELEPHONE/ELEC. ROOMS Communications Room1 1220 ELECTRICAL CLOSET Electrical Room1

1300A HALLWAYS Hallway1 1300B HALLWAYS Hallway1 1300C HALLWAYS Hallway1 1300D HALLWAYS Hallway1 1301 LOBBIES Probation Reception1 1302 RESTROOM Urinalysis Room1 1303 MEETING ROOMS Interview Room1 1304 OFFICES Office1 1305 TELEPHONE/ELEC. ROOMS Communications Room1 1306 OFFICES Office1 1307 ELECTRICAL CLOSET Electrical Room1 1308 OFFICES Office1

IHI Environmental 8

1309 OFFICES Office1 1310 OFFICES Office1 1311 STORAGE File Cabinets1 1312 OFFICES Office1 1313 OFFICES Office1 1314 OFFICES Office1 1315 OFFICES Office1 1316 OFFICES Office1 1317 OFFICES Office1 1318 OFFICES Office1 1319 OFFICES Office1 1320 OFFICES Office1 1321 OFFICES Office1 1322 OFFICES Office1 1323 OFFICES Office1 1324 OFFICES Office1 1326 OTHER Conference Room/Staff Lounge1 1327 OFFICES Work area1 1328 OFFICES Office1

1328A OFFICES Office1 1329 OFFICES Office1

1329A COPY ROOM Copy Room1 1330 STORAGE Storage1 1331 RESTROOM Staff Restroom1 1332 RESTROOM Staff Restroom1 1333 LOCKER ROOM Staff Lockers1 1400 GARAGES-PARKING AREAS Vehicle Sallyport1 1401 HALLWAYS Interlock1 1402 STORAGE Storage1 1403 HALLWAYS Sallyport for Prisoner Elevator1 1500 MAIL ROOM Mail Room1

1500A HALLWAYS Vestibule1 1500B HALLWAYS Loading Corridor1 1500C HALLWAYS Hallway1 1500D HALLWAYS Hallway1 1501 STORAGE Storage1 1502 MECHANICAL Chiller Room1 1503 MECHANICAL Generator Room1 1504 OFFICES Maintenance Office1

1504A RESTROOM Maintainace Restroom1 1505 MECHANICAL Gas Meter room1 1506 MECHANICAL Shaft - No Access1 2101 LOBBIES Elevator Lobby2

2101A HALLWAYS East End, South Corridor2 2101B HALLWAYS East End, East of Center Corridor2 2101C HALLWAYS North Side Corridor at Stairwell #32 2101D HALLWAYS Building Offices Corridor2 2102 STAIRWELLS Stairwell #32 2103 STAIRWELLS Stairwell #12 2104 STAIRWELLS Stairwell #22 2105 RESTROOM Women's Restroom2

IHI Environmental 9

2106 RESTROOM Men's Restroom2 2107 OFFICES Cleaning Office2

2107A JANITOR CLOSET Custodial Room2 2108 ELECTRICAL CLOSET Electrical Room2 2201 OFFICES Open Office2 2202 OFFICES Office2 2203 OFFICES Office2 2204 MEETING ROOMS Conference Room2 2205 STORAGE Storeroom / Copier2 2206 STORAGE Storage2 2301 OFFICES Office2 2302 OTHER File Room/Work/Mail2 2303 OFFICES Office2 2304 MEETING ROOMS Conference Room/Training Room2 2305 OFFICES Office2

2305A RESTROOM Restroom2 2305B CLOSET Closet2 2306 HALLWAYS West End, South Corridor2 2307 HALLWAYS West End, West Corridor2 2308 OFFICES Office2

2308A RESTROOM Restroom2 2308B CLOSET Closet2 2309 OFFICES Office2 2310 OFFICES Office2 2311 OFFICES Office2 2312 OFFICES Additional Office2 2313 STORAGE Storage2 2314 HALLWAYS West End, North Corridor2 2315 OTHER Break Room2 2316 ELECTRICAL CLOSET Electrical Room2 2317 TELEPHONE/ELEC. ROOMS Communications Room2 2318 HALLWAYS Interview Rooms Corridor2 2319 HALLWAYS Hallway2 2320 OFFICES Office2 2321 OFFICES Office2 2322 OFFICES Office2 2323 OFFICES Office2 2324 OTHER Isolation Cell #22

2324A HALLWAYS Sallyport for Isolation Cell #22 2325 OTHER Isolation Cell #12

2325A HALLWAYS Sallyport for Isolation Cell #12 2326 OTHER Main Detention Cell Block #12 2327 HALLWAYS Corridor between Cells and Interview Area2

2327B HALLWAYS Interlock2 2327C HALLWAYS Prisoner Lobby2 2327D HALLWAYS Sallyport2 2328 OTHER Isolation Cell #32

2328A HALLWAYS Sallyport for Isolation Cell #12 2329 OTHER Main Detention Cell Block #22 2330 OTHER Main Detention Cell Block #32 2331 OTHER Main Detention Cell Block #42

IHI Environmental 10

2332 OFFICES Processing2 2333 STORAGE Storage2 2334 HALLWAYS Sallyport to Lock-up2 2335 STORAGE Storage2 2336 HALLWAYS Corridor North of Stair #12 2337 FITNESS CENTER Fitness Room2

2337A OTHER North lockers2 2337B OTHER South lockers2 2337C OTHER North Shower2 2337D OTHER South Shower2 2338 STORAGE Storage2 2339 KITCHEN Prisoner Galley2 2340 WORK-ROOM Work Room2 2341 OFFICES Office2 2342 OFFICES Squad Room2 2343 OFFICES Office2 2344 MEETING ROOMS Conference Room2 2345 OFFICES Office2 2346 TELEPHONE/ELEC. ROOMS Communications Room2 2347 STORAGE Storage2 2348 OTHER Command and Control2 2349 OTHER Security Equipment Room2 2350 TELEPHONE/ELEC. ROOMS Communications Room2 2351 STORAGE Storage2 2352 RESTROOM Staff Restroom2 2353 RESTROOM Staff Restroom2

2354A HALLWAYS Corridor South of Reception2 2354B HALLWAYS Corridor South of Elevator Lobby2 2354C HALLWAYS East Side, South Corridor2 2354D HALLWAYS East Side Corridor2 3101 LOBBIES Visitor Waiting/Elevator Lobby3

3101A LOBBIES Public Elevator Lobby3 3101B HALLWAYS South Side of Elevator Lobby3 3101C HALLWAYS Corridor3 3101D HALLWAYS Corridor, North Side Center3 3102 STAIRWELLS Stairwell #33 3103 STAIRWELLS Stairwell #13 3104 STAIRWELLS Stairwell #23 3105 RESTROOM North Toilet3 3106 RESTROOM South Toilet3 3107 JANITOR CLOSET Custodial Room3 3108 HALLWAYS Corridor, East of Elevators3 3109 ELECTRICAL CLOSET Electrical Room3 3110 TELEPHONE/ELEC. ROOMS Communications Room3 3201 OFFICES Office3 3202 OFFICES Office3 3203 OFFICES Office3 3204 OFFICES Office3

3204A OFFICES Office3 3204B COPY ROOM Copy Room3 3205 OFFICES Office3

IHI Environmental 11

3206 OFFICES Office3 3207 OFFICES Office3 3208 OFFICES Office3

3208A HALLWAYS West Side, South Corridor3 3209 OFFICES Office3 3210 OFFICES Office3 3211 OFFICES Office3 3212 COPY ROOM Copy Room3 3213 MEETING ROOMS Conference Room3 3214 COPY ROOM Copy Room3 3215 MEETING ROOMS Waiting Room3

3215A HALLWAYS West Side, West Corridor3 3216 OFFICES Office3

3216A RESTROOM Restroom3 3217 OFFICES Office3 3218 OFFICES Office3 3219 STORAGE File Room3 3220 TELEPHONE/ELEC. ROOMS Communications Room3 3221 OFFICES Office3

3221A HALLWAYS West Side, North Corridor3 3222 OFFICES Office3 3223 MEETING ROOMS Conference Room3 3224 OFFICES Office3 3225 STORAGE Storage3 3226 OFFICES Office3 3227 OFFICES Office3 3228 OFFICES Office3 3229 OFFICES Office3 3230 ELECTRICAL CLOSET Electrical Room3 3231 OFFICES Office3 3232 TELEPHONE/ELEC. ROOMS Communications Room3 3233 LIBRARY Library3 3234 MEETING ROOMS Conference Room3

3234A CLOSET Bulk Storage3 3234B CLOSET Bulk Storage3 3235 RESTROOM Men's Restroom3

3235A RESTROOM Men's Shower3 3236 HALLWAYS Corridor3

3236A HALLWAYS East End, West Corridor3 3236B HALLWAYS East End, North Corridor3 3236C HALLWAYS East Side, East Corridor3 3236D HALLWAYS East End, South Corridor3 3236E HALLWAYS South Side, East of Center3 3236F HALLWAYS South USAO Corridor3 3237 COPY ROOM Copy Room3 3238 OFFICES Office3 3239 OFFICES Office3 3240 OFFICES Office3 3241 OFFICES Office3 3242 STORAGE File Room3 3243 OFFICES Office3

IHI Environmental 12

3244 STORAGE File Room3 3245 OFFICES Office3 3246 OFFICES Office3 3247 OFFICES Office3 3248 MEETING ROOMS Conference Room3 3249 OFFICES Office3 3250 OFFICES Office3 3251 OFFICES Office3 3252 MAIL ROOM Mail Room3 3253 COPY ROOM Copy Room3 3254 STORAGE Storage Room3 3255 OFFICES Office3 3256 OFFICES Office3 3257 OFFICES Office3 3258 OFFICES Office3

3258A OFFICES Office3 3259 OFFICES Office3 3260 MEETING ROOMS Conference Room3 3261 OFFICES Office3 3262 OFFICES Office3 3263 OFFICES Office3 3264 OFFICES Office3 3265 OFFICES Office3 3266 OTHER ADP Room3

3266A TELEPHONE/ELEC. ROOMS Communications Room3 3267 OFFICES Office3 3268 OFFICES Office3 3270 WORK-ROOM Work Room3 3271 STORAGE File Room3 3272 STORAGE Storage3 3273 COPY ROOM Copy Room3 3274 OFFICES Office3 3275 RESTROOM Women's Restroom3

3275A RESTROOM Women's Shower3 3276 OTHER Break Room3 3277 CLOSET Closet3 4101 LOBBIES Public Waiting Area and Elevator Lobby4

4101A OTHER Public Waiting Area4 4101B HALLWAYS Corridor by Stair #34 4101C HALLWAYS Public Corridor4 4101D HALLWAYS Women's Restroom Entryway4 4101E HALLWAYS To Stairwell #24 4101F HALLWAYS Stairwell #2 Exit Corridor4 4102 STAIRWELLS Stairwell #34 4103 STAIRWELLS Stairwell #14 4104 STAIRWELLS Stairwell #24 4105 RESTROOM Women's Restroom4 4106 RESTROOM Men's Restroom4 4107 JANITOR CLOSET Custodial Room4 4108 STAIRWELLS Stairwell #44 4201 MEETING ROOMS Jury Assembly Room4

IHI Environmental 13

4201A MEETING ROOMS Jury Assembly Room, Reception4 4202 OFFICES Office4 4203 CLOSET Closet4 4204 RESTROOM Restroom4 4205 RESTROOM Restroom4 4206 OTHER Jury Lounge4 4207 OTHER Vending Area4

4207A CLOSET Supply Room4 4208 LIBRARY Stack Area/Circulation4

4208A OFFICES Circulation/Reference Desk4 4208B CLOSET Storage for Stack Area4 4209 OFFICES Court Reporter4 4210 HALLWAYS Entry Corridor4

4210B CLOSET Closet4 4211 OTHER Security Station4 4212 OFFICES Witness Room4 4213 RESTROOM Grand Jury area4 4214 OFFICES Witness Room4 4216 RESTROOM Grand Jury Restroom4 4217 MEETING ROOMS Grand Jury Hearing Room4

4217A OTHER AV Room4 4218 HALLWAYS Secure Holding Sallyport4 4219 OTHER Secure Holding4 4220 OTHER Secure Holding4 4221 HALLWAYS Secure Holding Soundlock to Courtroom4

4221A CLOSET Storage4 4222 HALLWAYS Secure Holding Soundlock to Grand Jury

Room

4601 OFFICES Reception Office4 4601A CLOSET Closet4 4602 HALLWAYS Vestibule4 4603 OFFICES Office4

4603A RESTROOM Office4 4603B HALLWAYS Hallway4 4603C CLOSET Closet4 4604 OFFICES Clerk4 4605 OFFICES Clerk4 4606 MEETING ROOMS Conference Room4 4607 COPY ROOM Copy Room4

4607A OTHER Service Unit4 4608 MEETING ROOMS Conference Room4 4801 HALLWAYS Soundlock to Courtroom4 4802 MEETING ROOMS Conference Room4 4803 MEETING ROOMS Conference Room4 4804 MEETING ROOMS Conference Room4 4805 OTHER Magistrate Courtroom4 4806 OTHER AV Room4 4807 HALLWAYS Judge's Exit4

4807A HALLWAYS Corridor4 4807B HALLWAYS Corridor4 4807C HALLWAYS South Corridor4 4807D HALLWAYS Hallway4

IHI Environmental 14

4808 OTHER AV Room4 4809 OFFICES Sworn Jury Custodian / Soundlock4 4810 MEETING ROOMS Jury Room4

4810A RESTROOM Jury Room Restroom4 4810B RESTROOM Jury Room Restroom4 4810C CLOSET Closet4 4811 TELEPHONE/ELEC. ROOMS Communications Room4

4811A STORAGE Storage4 4812 RESTROOM Staff Restroom4 4813 RESTROOM Staff Restroom4 4814 HALLWAYS Vestibule4 4815 OFFICES Magistrate Chamber4

4815A RESTROOM Restroom4 4815B CLOSET Closet4 4816 OFFICES Clerk4 4817 COPY ROOM Copy Room4

4817A OTHER Service Unit4 4818 MEETING ROOMS Conference room4 4819 OFFICES Reception Office4 4820 TELEPHONE/ELEC. ROOMS Communications Room4 4821 ELECTRICAL CLOSET Electrical Room4 5101 LOBBIES Public Waiting Area and Elevator Lobby5

5101A HALLWAYS Hallway5 5101B HALLWAYS Men's Restroom Entryway5 5101C HALLWAYS Women's Restroom Entryway5 5101D HALLWAYS Hallway5 5102 STAIRWELLS Stairwell #35 5103 STAIRWELLS Stairwell #15 5104 STAIRWELLS Stairwell #25 5105 RESTROOM Women's Restroom5 5106 RESTROOM Men's Restroom5

5106A JANITOR CLOSET Custodial Room5 5106B HALLWAYS North Corridor5 5201 OTHER Soundlock to Courtroom5 5202 MEETING ROOMS Conference Room5 5203 OTHER District Courtroom5 5204 HALLWAYS Judges Exit5 5205 STORAGE Storage5 5206 OTHER A/V Room5 5207 OFFICES Sworn Jury Custodian / Soundlock5 5210 MEETING ROOMS North Jury Room5

5210A RESTROOM Jury Restroom5 5210B RESTROOM Jury Restroom5 5210C CLOSET Closet5 5211 STORAGE Storage5 5212 OFFICES Office5 5213 HALLWAYS Vestibule5 5214 OFFICES District Judge5

5214A CLOSET Closet5 5214B RESTROOM Restroom5 5215 OFFICES Clerk5

IHI Environmental 15

5216 OFFICES Clerk5 5217 COPY ROOM Copy Room5 5218 MEETING ROOMS Conference Room5 5219 OFFICES Reception Office5

5219A CLOSET Closet5 5219B HALLWAYS Judicial Office Hallway5 5501 HALLWAYS Soundlock to Courtroom5 5502 MEETING ROOMS Conference Room5 5503 OTHER District Courtroom5 5504 STORAGE Storage5 5505 HALLWAYS Judge's Exit5

5506A HALLWAYS Hallway5 5506B HALLWAYS Hallway5 5506C HALLWAYS Hallway5 5506D HALLWAYS Hallway5 5507 OTHER Communications Room5 5508 HALLWAYS Hallway5 5509 RESTROOM Staff Restroom5 5510 STORAGE A/V Room5 5511 RESTROOM Staff Restroom5 5512 HALLWAYS South Corridor5 5513 OFFICES Sworn Jury Custodian / Soundlock5 5514 MEETING ROOMS South Jury Room5

5514A RESTROOM Jury Restroom5 5514B RESTROOM Jury Restroom5 5514C CLOSET Closet5 5515 HALLWAYS Vestibule5 5516 OFFICES District Judge5

5516A CLOSET Closet5 5516B RESTROOM Restroom5 5517 OFFICES Clerk5 5518 OFFICES Clerk5 5519 COPY ROOM Copy Room5 5520 MEETING ROOMS Conference Room5 5521 OFFICES Reception Office5

5521A CLOSET Closet5 5521B HALLWAYS Judicial Office Hallway5 5522 TELEPHONE/ELEC. ROOMS Communications Room5 5523 ELECTRICAL CLOSET Electrical Room5 5902 HALLWAYS Secure Holding Soundlock to Courtroom5 5903 HALLWAYS Secure Holding Soundlock to Courtroom5 5904 OTHER Secure Holding Cell5

5904A OTHER Secure Holding Sallyport5 5905 OTHER Secure Holding Cell5 5906 OTHER Secure Holding Cell5 5M PENTHOUSE Mechanical Systems and Water TreatmentPH 5M

B001 GARAGES-PARKING AREAS ParkingB B002 STORAGE StoreroomB B003 ELECTRICAL CLOSET SwitchgearB B004 STORAGE StoreroomB B005 MECHANICAL Elevator Pit - Secure ElevatorB

IHI Environmental 16

B006 STORAGE StoreroomB B007 STORAGE Maintenance StorageB B008 LOBBIES Judges Elevator LobbyB B009 LOBBIES Service Elevator LobbyB B010 MECHANICAL Elevator Control RoomB B011 STORAGE Demarc RoomB B012 MECHANICAL East Mechanical ShaftB B013 STORAGE Chain Link Fenced Storage CageB B014 STORAGE Chain Link Fenced Storage CageB B015 STORAGE Chain Link Fenced Storage CageB B016 STORAGE Chain Link Fenced Storage CageB B017 STORAGE Chain Link Fenced Storage CageB B018 MECHANICAL Fire Pump RoomB B019 MECHANICAL Domestic Pump RoomB B020 STORAGE Chain Link Fenced Storage CageB B021 MECHANICAL MechanicalB B022 MECHANICAL StoreroomB B023 STORAGE Chain Link Fenced Storage CageB B024 STORAGE Maintenance Storage RoomB B025 ELECTRICAL CLOSET Domestic Hot Water RoomB B101 LOBBIES Public Elevator LobbyB B102 STAIRWELLS Stairwell #1B CA30 ELEVATOR ROOM/HOISTWAYS Judges Elevator #4 (Serves Floors B to 5)B

E Roof ROOFS Main Roof and Screened Mechanical AreasRoof MD3.1 ELEVATOR ROOM/HOISTWAYS Prisoner Elevator #5 (Serves Floors 1, 2, 4, and 5)

W Roof ROOFS Garden TerraceRoof ZA MECHANICAL Elevator Machine Room (Elevator Cars # 1

& #2)

PH 5M

ZA19.2 MECHANICAL Vertical Mechanical Chase from 2/F to Penthouse

ZA-2 MECHANICAL Elevator Machine Room (Elevator Cars # 3, #4 & #5)

PH 5M

ZA33 MECHANICAL Mechanical PenthousePH 5M ZE1A ELEVATOR ROOM/HOISTWAYS Public Elevator #1 (Serves Floors B to 5)B ZE2A ELEVATOR ROOM/HOISTWAYS Public Elevator #2 (Serves Floors B to 5)B ZE3A ELEVATOR ROOM/HOISTWAYS Service Elevator #3 (Serves Floors B to 5A)B

IHI Environmental 17

TABLE B: Room-by-Room Summary of Suspect and Confirmed ACBM's

Facility Name: James F. Battin Federal Courthouse Address: 2601 2nd Ave. North City, State, ZIP Code: Billings, MT 59101

MT0050

Date of Inspection: 08/05/2013 Site Inspected By: Brian RamsellBuilding Number:

NESHAP

CategoryUNIT

Floor No.

Room No. Room Description

Material Type

Homogeneous Material

Description Sample No. AHERA

Category*

ACBM

QTY ACBM Friable Material Number and Comments

M Wallboard/Taping Material

1000 No No 01 Entry Vestibule M3.1 - Drywall and taping mud

N/A N/A1000 No No 01 Entry Vestibule Glass - Non-Suspect

N/A N/A1000 No No 01 Entry Vestibule Metal - Non-suspect

F Other Flooring1000 No No 01 Entry Vestibule Terrazzo - Non-Suspect

S Spray-on Fireproofing1000 No Yes 01 Entry Vestibule S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities and above ceilings, as well as the decking above the ceiling.

Both types / colors were sampled and found to be non-asbestos

N/A Straight Pipe Insulation1000 No No 01 Entry Vestibule Fiberglass - Non-Suspect - on pipes and pipe fittings

M Other1000 No No 01 Entry Vestibule M16.8 - Dark Gray Duct Sealant

M Caulking1000 No No 01 Entry Vestibule M8.1 -Red Fire Caulk

M Other1000 No No 01 Entry Vestibule M16.7 - Gray Duct Sealant

18IHI Environmental

*An AHERA Category of more than zero (0) means that the material is regulated friable asbestos. In the AHERA Column 'N/A' means that the material is non-friable and is not ranked per AHERA.

NESHAP

CategoryUNIT

Floor No.

Room No. Room Description

Material Type

Homogeneous Material

Description Sample No. AHERA

Category*

ACBM

QTY ACBM Friable Material Number and Comments

M Other1000 No No 01 Entry Vestibule M16.1 - White Sealant - found on pipe insulation ends and joints

F Other Flooring1001 No No 01 Security Queuing Terrazzo - Non-Suspect

M Wallboard/Taping Material

1001 No No 01 Security Queuing M3.1 - Drywall and taping mud

S Spray-on Fireproofing1001 No Yes 01 Security Queuing S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities and above ceilings, as well as the decking above the ceiling.

Both types / colors were sampled and found to be non-asbestos

M Other1001 No No 01 Security Queuing Plastic (Polymer) Wall Panels - Non-suspect - Note: Wood, stone, metal, polymer and fabric covered panels are affixed to walls by means unknown to the inspector(s). Should adhesive(s) be encountered during the removal of any of these panels, the adhesive(s) should be treated as an assumed asbestos containing material until it can be proven otherwise.

N/A Straight Pipe Insulation1001 No No 01 Security Queuing Fiberglass - Non-Suspect - on pipes and pipe fittings

M Other1001 No No 01 Security Queuing M16.7 - Gray Duct Sealant

M Other1001 No No 01 Security Queuing M16.8 - Dark Gray Duct Sealant

M Caulking1001 No No 01 Security Queuing M8.1 -Red Fire Caulk

M Other1001 No No 01 Security Queuing M16.1 - White Sealant - found on pipe insulation ends and joints

M Other1002 No No 01 Lobby Security M16.1 - White Sealant - found on pipe insulation ends and joints

19IHI Environmental

*An AHERA Category of more than zero (0) means that the material is regulated friable asbestos. In the AHERA Column 'N/A' means that the material is non-friable and is not ranked per AHERA.

NESHAP

CategoryUNIT

Floor No.

Room No. Room Description

Material Type

Homogeneous Material

Description Sample No. AHERA

Category*

ACBM

QTY ACBM Friable Material Number and Comments

S Spray-on Fireproofing1002 No Yes 01 Lobby Security S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities and above ceilings, as well as the decking above the ceiling.

Both types / colors were sampled and found to be non-asbestos

M Wallboard/Taping Material

1002 No No 01 Lobby Security M3.1 - Drywall and taping mud

F Other Flooring1002 No No 01 Lobby Security Terrazzo - Non-Suspect

M Other1002 No No 01 Lobby Security Plastic (Polymer) Wall Panels - Non-suspect - Note: Wood, stone, metal, polymer and fabric covered panels are affixed to walls by means unknown to the inspector(s). Should adhesive(s) be encountered during the removal of any of these panels, the adhesive(s) should be treated as an assumed asbestos containing material until it can be proven otherwise.

S Spray-on Fireproofing1002 No Yes 01 Lobby Security S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities and above ceilings, as well as the decking above the ceiling.

Both types / colors were sampled and found to be non-asbestos

N/A N/A1002 No No 01 Lobby Security Metal - Non-suspect

M Other1002 No No 01 Lobby Security M16.8 - Dark Gray Duct Sealant

M Other1002 No No 01 Lobby Security M16.7 - Gray Duct Sealant

M Caulking1002 No No 01 Lobby Security M8.1 -Red Fire Caulk

N/A Straight Pipe Insulation1002 No No 01 Lobby Security Fiberglass - Non-Suspect - on pipes and pipe fittings

20IHI Environmental

*An AHERA Category of more than zero (0) means that the material is regulated friable asbestos. In the AHERA Column 'N/A' means that the material is non-friable and is not ranked per AHERA.

NESHAP

CategoryUNIT

Floor No.

Room No. Room Description

Material Type

Homogeneous Material

Description Sample No. AHERA

Category*

ACBM

QTY ACBM Friable Material Number and Comments

N/A N/A1002 No No 01 Lobby Security Glass - Non-Suspect

M Wallboard/Taping Material

1002 No No 01 Lobby Security M3.1 - Drywall and taping mud

F Other Flooring1002 No No 01 Lobby Security Terrazzo - Non-Suspect

S Spray-on Fireproofing1003 No Yes 01 Fire Command Room S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities and above ceilings, as well as the decking above the ceiling.

Both types / colors were sampled and found to be non-asbestos

M Baseboard/Mastic1003 No No 01 Fire Command Room M12.1 -Tan Cove Base Mastic

M Wallboard/Taping Material

1003 No No 01 Fire Command Room M3.1 - Drywall and taping mud

F 12" x 12" Floor Tile1003 No No 01 Fire Command Room F2.1 - 12" x 12" Off White Speckled Floor Tile and Yellow Adhesive

M Ceiling Tiles1003 No Yes 01 Fire Command Room M6.1 - 2' x 2' and 2' x 6' Ceiling Panels with Sandpaper-like Texture, White

M Other1101 No No 01 Main Building/Elevator lobby

M16.1 - White Sealant - found on pipe insulation ends and joints

S Spray-on Fireproofing1101 No Yes 01 Main Building/Elevator lobby

S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities and above ceilings, as well as the decking above the ceiling.

Both types / colors were sampled and found to be non-asbestos

M Adhesive1101 No No 01 Main Building/Elevator lobby

M16.9 - Tan Wall Panel Adhesive - for vinyl wall panels

M Wallboard/Taping Material

1101 No No 01 Main Building/Elevator lobby

M3.1 - Drywall and taping mud

21IHI Environmental

*An AHERA Category of more than zero (0) means that the material is regulated friable asbestos. In the AHERA Column 'N/A' means that the material is non-friable and is not ranked per AHERA.

NESHAP

CategoryUNIT

Floor No.

Room No. Room Description

Material Type

Homogeneous Material

Description Sample No. AHERA

Category*

ACBM

QTY ACBM Friable Material Number and Comments

M Other1101 No No 01 Main Building/Elevator lobby

Plastic (Polymer) Wall Panels - Non-suspect - Note: Wood, stone, metal, polymer and fabric covered panels are affixed to walls by means unknown to the inspector(s). Should adhesive(s) be encountered during the removal of any of these panels, the adhesive(s) should be treated as an assumed asbestos containing material until it can be proven otherwise.

N/A N/A1101 No No 01 Main Building/Elevator lobby

Wood - Non-Suspect - Note: Wood, stone, metal, polymer and fabric covered panels are affixed to walls by means unknown to the inspector(s). Should adhesive(s) be encountered during the removal of any of these panels, the adhesive(s) should be treated as an assumed asbestos containing material until it can be proven otherwise.

F Other Flooring1101 No No 01 Main Building/Elevator lobby

Terrazzo - Non-Suspect

M3.2-A, M3.2-B, M3.2-C

M Wallboard/Taping Material

1101 No No 01 Main Building/Elevator lobby

M3.2 - Foil backed drywall and taping mud

M Caulking1101 No No 01 Main Building/Elevator lobby

M8.1 -Red Fire Caulk

N/A Straight Pipe Insulation1101 No No 01 Main Building/Elevator lobby

Fiberglass - Non-Suspect - on pipes and pipe fittings

M Other1101 No No 01 Main Building/Elevator lobby

M16.8 - Dark Gray Duct Sealant

M Other1101 No No 01 Main Building/Elevator lobby

M16.7 - Gray Duct Sealant

NoneM Fire Door Insulation1101A 1 Yes No 71 Vestibule to Probation Reception

Category 2EAM9.1 - Fire Door Insulation, Assumed ACM -all fire rated doors shall be assumed to have asbestos containing cores unless labeled as being non-asbestos containing or sampled and proven to be non-asbestos containing.

M Wallboard/Taping Material

1101A No No 01 Vestibule to Probation Reception

M3.1 - Drywall and taping mud

22IHI Environmental

*An AHERA Category of more than zero (0) means that the material is regulated friable asbestos. In the AHERA Column 'N/A' means that the material is non-friable and is not ranked per AHERA.

NESHAP

CategoryUNIT

Floor No.

Room No. Room Description

Material Type

Homogeneous Material

Description Sample No. AHERA

Category*

ACBM

QTY ACBM Friable Material Number and Comments

M Wallboard/Taping Material

1101A No No 01 Vestibule to Probation Reception

M3.2 - Foil backed drywall and taping mud

S Spray-on Fireproofing1101A No Yes 01 Vestibule to Probation Reception

S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities and above ceilings, as well as the decking above the ceiling.

Both types / colors were sampled and found to be non-asbestos

M Adhesive1101A No No 01 Vestibule to Probation Reception

M16.9 - Tan Wall Panel Adhesive - for vinyl wall panels

M Other1101A No No 01 Vestibule to Probation Reception

Plastic (Polymer) Wall Panels - Non-suspect - Note: Wood, stone, metal, polymer and fabric covered panels are affixed to walls by means unknown to the inspector(s). Should adhesive(s) be encountered during the removal of any of these panels, the adhesive(s) should be treated as an assumed asbestos containing material until it can be proven otherwise.

F Other Flooring1101A No No 01 Vestibule to Probation Reception

Terrazzo - Non-Suspect

NoneM Fire Door Insulation1101B 1 Yes No 71 West side, South Vestibule

Category 2EAM9.1 - Fire Door Insulation, Assumed ACM -all fire rated doors shall be assumed to have asbestos containing cores unless labeled as being non-asbestos containing or sampled and proven to be non-asbestos containing.

S Spray-on Fireproofing1101B No Yes 01 West side, South Vestibule

S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities and above ceilings, as well as the decking above the ceiling.

Both types / colors were sampled and found to be non-asbestos

F Other Flooring1101B No No 01 West side, South Vestibule

Terrazzo - Non-Suspect

23IHI Environmental

*An AHERA Category of more than zero (0) means that the material is regulated friable asbestos. In the AHERA Column 'N/A' means that the material is non-friable and is not ranked per AHERA.

NESHAP

CategoryUNIT

Floor No.

Room No. Room Description

Material Type

Homogeneous Material

Description Sample No. AHERA

Category*

ACBM

QTY ACBM Friable Material Number and Comments

M Other1101B No No 01 West side, South Vestibule

Plastic (Polymer) Wall Panels - Non-suspect - Note: Wood, stone, metal, polymer and fabric covered panels are affixed to walls by means unknown to the inspector(s). Should adhesive(s) be encountered during the removal of any of these panels, the adhesive(s) should be treated as an assumed asbestos containing material until it can be proven otherwise.

M Wallboard/Taping Material

1101B No No 01 West side, South Vestibule

M3.2 - Foil backed drywall and taping mud

M Wallboard/Taping Material

1101B No No 01 West side, South Vestibule

M3.1 - Drywall and taping mud

NoneM Fire Door Insulation1102 1 Yes No 71 Stairwell #3 Category 2EAM9.1 - Fire Door Insulation, Assumed ACM -all fire rated doors shall be assumed to have asbestos containing cores unless labeled as being non-asbestos containing or sampled and proven to be non-asbestos containing.

N/A N/A1102 No No 01 Stairwell #3 CMU - Non-Suspect - walls

S Spray-on Fireproofing1102 No Yes 01 Stairwell #3 S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities, stairwells, and above ceilings, as well as the decking above the ceiling. Both types / colors were sampled and found to be non-asbestos

M Wallboard/Taping Material

1102 No No 01 Stairwell #3 M3.1 - Drywall and taping mud

N/A N/A1102 No No 01 Stairwell #3 Metal - Non-suspect - stairs

M Fire Door Insulation1103 1 Yes No 71 Stairwell #1 Category 2EAM9.1 - Fire Door Insulation, Assumed ACM -all fire rated doors shall be assumed to have asbestos containing cores unless labeled as being non-asbestos containing or sampled and proven to be non-asbestos containing.

24IHI Environmental

*An AHERA Category of more than zero (0) means that the material is regulated friable asbestos. In the AHERA Column 'N/A' means that the material is non-friable and is not ranked per AHERA.

NESHAP

CategoryUNIT

Floor No.

Room No. Room Description

Material Type

Homogeneous Material

Description Sample No. AHERA

Category*

ACBM

QTY ACBM Friable Material Number and Comments

S Spray-on Fireproofing1103 No Yes 01 Stairwell #1 S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities, stairwells, and above ceilings, as well as the decking above the ceiling. Both types / colors were sampled and found to be non-asbestos

M Wallboard/Taping Material

1103 No No 01 Stairwell #1 M3.1 - Drywall and taping mud

N/A N/A1103 No No 01 Stairwell #1 Metal - Non-suspect - stairs

N/A N/A1103 No No 01 Stairwell #1 CMU - Non-Suspect - walls

NoneM Fire Door Insulation1104 1 Yes No 71 Stairwell #2 Category 2EAM9.1 - Fire Door Insulation, Assumed ACM -all fire rated doors shall be assumed to have asbestos containing cores unless labeled as being non-asbestos containing or sampled and proven to be non-asbestos containing.

M Wallboard/Taping Material

1104 No No 01 Stairwell #2 M3.1 - Drywall and taping mud

N/A N/A1104 No No 01 Stairwell #2 CMU - Non-Suspect - walls

N/A N/A1104 No No 01 Stairwell #2 Metal - Non-suspect - stairs

S Spray-on Fireproofing1104 No Yes 01 Stairwell #2 S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities, stairwells, and above ceilings, as well as the decking above the ceiling. Both types / colors were sampled and found to be non-asbestos

NoneM Other1105 386 Yes No N/A1 Women's Restroom Category 2SFM16.2 - Ceramic Tile Grout and Adhesive, Assumed ACM - floor and walls

25IHI Environmental

*An AHERA Category of more than zero (0) means that the material is regulated friable asbestos. In the AHERA Column 'N/A' means that the material is non-friable and is not ranked per AHERA.

NESHAP

CategoryUNIT

Floor No.

Room No. Room Description

Material Type

Homogeneous Material

Description Sample No. AHERA

Category*

ACBM

QTY ACBM Friable Material Number and Comments

S Spray-on Fireproofing1105 No Yes 01 Women's Restroom S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities, stairwells, and above ceilings, as well as the decking above the ceiling. Both types / colors were sampled and found to be non-asbestos

M Wallboard/Taping Material

1105 No No 01 Women's Restroom M3.1 - Drywall and taping mud - walls and ceiling

M Other1106 386 Yes No N/A1 Men's Restroom Category 2SFM16.2 - Ceramic Tile Grout and Adhesive, Assumed ACM - floor and walls

M Wallboard/Taping Material

1106 No No 01 Men's Restroom M3.1 - Drywall and taping mud - walls and ceiling

S Spray-on Fireproofing1106 No Yes 01 Men's Restroom S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities, stairwells, and above ceilings, as well as the decking above the ceiling. Both types / colors were sampled and found to be non-asbestos

M Other1107 110 Yes No N/A1 Custodial Room Category 2SFM16.2 - Ceramic Tile Grout and Adhesive, Assumed ACM - floor and walls

M6.2-AM Ceiling Tiles1107 No Yes 01 Custodial Room M6.2 - 2' x 2' Ceiling Panels with Spray Texture, White

S Spray-on Fireproofing1107 No Yes 01 Custodial Room S2.1 - Beige Fireproofing - Fireproofing, either beige or grey, is present on all structural members in wall cavities, stairwells, and above ceilings, as well as the decking above the ceiling. Both types / colors were sampled and found to be non-asbestos

M Wallboard/Taping Material

1107 No No 01 Custodial Room M3.1 - Drywall and taping mud

NoneM Fire Door Insulation1201 2 Yes No 71 Office Category 2EAM9.1 - Fire Door Insulation, Assumed ACM -all fire rated doors shall be assumed to have asbestos containing cores unless labeled as being non-asbestos containing or sampled and proven to be non-asbestos containing.

26IHI Environmental

*An AHERA Category of more than zero (0) means that the material…