OPERATIONS AND MAINTENANCE INSPECTION REPORT
MARTIN V. BOSTETTER COURTHOUSE (VA0003ZZ)
Prepared for:
General Services Administration
Safety Environment and Fire Protection Branch National Capital Region
301 7th Street, S.W., Room 2080 Washington, DC 20407
Prepared By:
TTL-Arc Environmental, JV LLC
November 25, 2016
Contract No. GS11P-12-DC-C-0008
PDN No. PJ4NA1560 Order No. GS-P-11-15-DC-5007
Reviewed by:
Stacy Kahatapitiya, CHMM, LEED GA Jean Mlynek, CIH, Project Manager Certified Industrial Hygienist
JV
Table of Contents
1.0 INTRODUCTION
2.0 SCOPE AND OBJECTIVES
3.0 LOCATIONS OF ACBM
3.1 Previous Surveys
3.2 Current Survey (2016)
4.0 RECOMMENDATIONS
APPENDICES
APPENDIX A Asbestos-Containing Materials Inventory APPENDIX B Non-Asbestos Containing Materials Inventory APPENDIX C Laboratory Analytical Results APPENDIX D GSA Inspection Forms APPENDIX E Accreditation Information APPENDIX F Site Drawings APPENDIX G Summary of Abatement Actions
Asbestos Operations and Maintenance Inspection Report November 2016 Martin V. Bostetter Courthouse (VA0003ZZ)
1.0 INTRODUCTION
In accordance with our Industrial Hygiene Services contract with the General Services Administration (GSA), TTL-Arc Environmental, JV (TTL-Arc) completed the Asbestos Hazard Emergency Response Act (AHERA) Operations and Maintenance (O&M) inspection of the Martin V. Bostetter Courthouse (Bostetter Courthouse) (VA0003ZZ). The Bostetter Courthouse is located at 200 South Washington Street in Alexandria, Virginia. The purpose of the survey was to assess previously identified asbestos-containing materials (ACMs) and to identify and sample additional suspect ACMs not previously identified.
2.0 SCOPE AND OBJECTIVES
The principle objective of the O&M Survey was to conduct a visual inspection of known asbestos containing building materials (ACBMs) and presumed asbestos containing building materials (PACMs) within the building to verify quantities and conditions. Limited bulk sampling of previously unidentified materials which are suspect to contain asbestos were also conducted as part of the inspection; sampling was prioritized by material type and potential for disturbance. Sampling within the Bostetter Courthouse was limited to 30 samples per the contract.
3.0 LOCATIONS OF ACBM
Multiple surveys and re-inspections have been conducted over the years, with the most recent re-inspection occurring in October 2014. This section summarizes the previous survey data and analytical results made available to TTL-Arc for review. A full inventory of ACMs is provided in Appendix A; a list of sampled suspect materials which were determined to be non-asbestos containing is included in Appendix B. Laboratory analytical results for all samples collected within the building is included in Appendix C. Copies of the GSA asbestos inspections forms are provided in Appendix D.
3.1 Previous Surveys
Previous surveys have identified ACMs within the building in the form of floor tiles, thermal system insulation (TSI), and miscellaneous materials. These materials were verified during the 2016 survey and are listed in Appendix A.
3.2 Current Survey (2016)
TTL-Arc reviewed the 2014 re-inspection report provided by GSA. The areas previously identified as ACMs were inspected to verify the quantity and evaluate the condition of the materials. A visual inspection of accessible portions of the entire building was also conducted to identify and sample materials suspect to be asbestos-containing which were not previously identified; areas which were not accessible at the time of the survey included the following locations:
Suite 200 Judge’s Chamber U.S. Marshall’s Service Court Security
Per the contract language, GSA did not allow samples to be collected in rooms which were occupied. Any suspect ACMs in occupied rooms or inaccessible areas that could not be sampled were classified as Presumed ACMs (PACMs). Unless proven otherwise, PACMs must be treated as asbestos-containing.
The asbestos survey and bulk sample collection was conducted by TTL-Arc’s Asbestos Building Inspector, Mr. Derek Kwon. Mr. Kwon has received asbestos inspector training from a training provider accredited by the U.S. Environmental Protection Agency (USEPA).
3.2.1 Methodology
TTL-Arc conducted the asbestos survey under protocols established by USEPA 40 Code of Federal Regulations (CFR) 763 Asbestos Hazard Emergency Response Act (AHERA) and 40 CFR 61 Subpart M, National Emission Standards for Hazardous Air Pollutants (NESHAP). GSA-established protocols for asbestos bulk sampling were also adhered to during the survey.
Every reasonable attempt was made to locate ACMs present as TSI, surfacing material, or other miscellaneous materials which had not been previously identified. Specifically, TTL-Arc employed the following protocols while performing the survey: flooring materials were penetrated to the subfloor to determine how many layers of flooring were present; wall systems and ceiling systems were evaluated to identify suspect building materials associated with the systems themselves, as well as any accessible cavities; and mechanical insulation systems were evaluated to identify potential suspect insulation.
During the survey, TTL-Arc collected a total of 32 bulk samples of suspect materials from within the building. Several suspect ACMs were presumed to be asbestos-containing until such a time when additional bulk sampling is authorized. The bulk samples were submitted, along with the corresponding chain-of-custody documentation, to EMSL Analytical, Inc. (EMSL) to determine the presence of asbestos in the sampled materials. EMSL is accredited for the analysis of asbestos in bulk materials through the National Voluntary Laboratory Accreditation Program (NVLAP). A total of 43 analyses resulted from the 26 submitted samples based on requirements to analyze discrete layers present within the bulk materials. The bulk samples were analyzed using polarized light microscopy (PLM/Dispersion Staining following the EPA method 600/R-93/116, Method for the Determination of Asbestos in Bulk Building Materials). Based on the United States Environmental Protection Agency's (USEPA’s) definition, a material which contains greater than one percent (1%) asbestos, as determined using the methods specified in Appendix E, Subpart E, 40 CFR Part 763, Section 1, Polarized Light Microscopy (PLM), is considered an ACM and must be handled according to OSHA, USEPA, and Commonwealth of Virginia regulations.
3.2.2 Results
Based on the laboratory analytical results, none of the materials sampled during the current survey were determined to be asbestos-containing by PLM analysis. Additionally, thirteen (13) materials were categorized as PACMs due to conditions preventing these materials from being sampled.
Table 1, below, summarizes previously unidentified suspect materials that were determined to be asbestos-containing by laboratory analysis or assumed to be asbestos-containing during the current survey. A comprehensive list of all previously and newly identified asbestos-containing materials located within the building can be found in Appendix A; a list of materials which were tested and found to not contain asbestos are included in Appendix B.
Table 1: Asbestos-containing Materials Identified During 2016 Survey
HA Material Description Location Quantity Sample Number Result
TZ1
Brown, Grey and Beige Stone
Design Terrazzo
3rd fl. Stairwell/Elevator Lobby, 2nd fl.
Stairwell/Elevator Lobby, Men’s
Restrooms, Women’s Restroom, 3rd fl.
Mech. Room, 1st fl. Security Station, 1st
fl. Hallway, Basement Restroom
3,934 SF N/A PACM
CT1
1’x1’ Ceiling Tile with Fissure and Mastic Daub Courtroom 3 1,302 SF N/A PACM
CT2
2’x2’ Ceiling Tile with Divots and Pinholes Throughout the Building 4,544 SF N/A PACM
SI1 Beige Sink Undercoating 300 Suite Kitchen 1 EA N/A PACM
PL3 Decorative Plaster
3rd fl. Hallway, 2nd fl. Hallway, 2nd fl.
Stairwell Lobby/Elevator Lobby, Lobby outside Rm. 207, 1st fl. Security Station, 1st fl. Hallway, Suite 103 Lunch Room, 1st
fl. Old Courtroom
1,026 SF N/A PACM
FD1 Fire Door
3rd fl. Elevator Lobby, 2nd fl. Elevator Lobby, 1st fl. Elevator Lobby, Basement Telephone Closet, Basement Electrical
Closet, Chiller Room
14 EA N/A PACM
VT1
12”x12” White Floor Tile with Grey Streaks and Associated
Mastic 300 Suite Kitchen 72 SF N/A PACM
VT2
12”x12” White Floor Tile with Multi Different Color Streaks and Associated Mastic Suite 206 Judge’s Chamber Kitchen 221 SF N/A PACM
VT3
12”x12” Beige Mottled Floor Tile and Associated Mastic
Basement Hallway by Holding Cell (Cage Room), Pipe Room, Basement Storage
Room, Basement Back Hallway, Basement Main Hallway, Hallway outside large Storage Room
1,964 SF N/A PACM
Table 1: Asbestos-containing Materials Identified During 2016 Survey
HA Material Description Location Quantity Sample Number Result
VT4
12”x12” Light Grey Floor Tile with Dark Grey Streaks and Associated Mastic
Janitorial Storage Closet 156 SF N/A PACM
VT5
9”x9” Green Floor Tile underneath the carpet
Basement Storage 500 SF N/A PACM
BBM2
4” Red Baseboard and
Associated Mastic
1st fl. Back Office Suite Hallway, Back Office Suite Office 2, Office 3, Clerk
Station, Pipe Room, Basement Storage Room
378 LF N/A PACM
Noise Dampener
Noise Dampener 1st Fl. Old Court Room 800 SF N/A PACM
HA = Homogeneous Area
Asbestos Operations and Maintenance Inspection Report November 2016
4.0 RECOMMENDATIONS
The following recommendations are based on the results of the re-inspection:
All asbestos-containing or PACMs identified within this report should be maintained in good condition through the continuation of the Operations and Maintenance (O&M) Program;
Any damaged and/or significantly damaged ACBM identified during the re-inspection should be removed, enclosed, encapsulated, or repaired (Damaged materials are highlighted in yellow in Table 2); and
Materials which have not been sampled to determine asbestos-content should be treated as PACM and included in the O&M Program.
APPENDIX A
ASBESTOS-CONTAINING MATERIALS
INVENTORY
Table 2: Asbestos-Containing Materials Inventory
HA Sample Number Location Material
Description Quantity Friable Condition Results
Quantity of
Damage
Estimated Abatement
Costs
Recommended Response
Action
DIM1
BC-101614-02A,
BC-101614-02B,
BC-101614-02C
Attic Black Mastic on Duct Insulation
Wrap 159 LF No Damaged
Identified in 2014 Survey 14 LF $391.14 Repair
DIM2 N/A
Attic, 3rd fl. Mech.
Room
Beige Seam Sealant Mastic on Foil Duct
Wrap 82 LF No Damaged
Assumed in 2014 Survey
3 LF $201.72 Repair
DIM3 N/A
Attic, 2nd fl. Mech.
Room
Black Seam Sealant Mastic on Foil Duct
Wrap 30 LF No Damaged
Assumed in 2014 Survey
5 LF $73.80 Repair
DI1 N/A Chiller Room Duct Insulation 52 LF Yes Good Assumed in 2014 Survey
N/A $434.72 O&M
Fit1
BC-101614-04A,
BC-101614-04B,
BC-101614-04C
Attic, 3rd fl. Mech.
Room
Mudded Fitting 5 EA Yes Damaged Identified in 2014 Survey 1 EA $109.75 Remove
PI1 N/A
Attic, 2nd fl. Mech.
Room Cork Pipe Insulation with Black Mastic
235 LF No Good Assumed in 2014 Survey
N/A $1,964.60 O&M
PI2 N/A 3rd fl. Mech. Room Hard Mag Pipe
Insulation 10 LF Yes Good
Assumed in 2014 Survey
N/A $83.60 O&M
Material
Description Quantity Friable Condition Results
Quantity of
Damage
Estimated Abatement
Costs
Recommended Response
Action
PIM1 N/A
Attic, Basement Custodial Office, Pump Room, Hallway by Old
Holding Cell (Cage Room), Pipe Room, Telephone Closet 1, Electrical Closet, B13 Mech. Room, Basement Main Hallway, Chiller
Room, Large Storage Room, Computer
Storage Room, Server Room, Office next to Server Room, Janitorial Storage Closet
White Pipe Seam Sealant Mastic
1,601 LF No Damaged Assumed in 2014 Survey 26 LF $3,938.46 Repair
PIM2 N/A Attic Black Mastic on Pipe
Wrap 64 LF No Good
Assumed in 2014 Survey
N/A $157.44 O&M
PIW1 N/A Attic Paper Pipe Wrap with Foil Backing and Black Mastic
18 LF No Damaged Assumed in 2014 Survey 3 LF $44.28 Repair
VC1
BC-101614-01A,
BC-101614-01B,
BC-101614-01C
Attic Vibration Collar 26 LF No Damaged Identified in 2014 Survey 1 LF $45.00 Repair
Material
Description Quantity Friable Condition Results
Quantity of
Damage
Estimated Abatement
Costs
Recommended Response
Action
TZ1 N/A
3rd fl.
Stairwell/Elevator
Lobby, 2nd fl.
Stairwell/Elevator
Lobby, Men’s Restrooms, Women’s
Restroom, 3rd fl.
Mech. Room, 1st fl.
Security Station, 1st fl.
Hallway, Basement
Restroom
Brown, Grey and Beige Stone Design
Terrazzo 3,934 SF No Good PACM N/A $10,936.52 O&M
CT1 N/A Courtroom 3 1’x1’ Ceiling Tile with Fissure and
Mastic Daub 1,302 SF No Good
PACM N/A $2,343.60 O&M
CT2 N/A
Throughout the
Building
2’x2’ Ceiling Tile with Divots and
Pinholes 4,544 SF No Good PACM N/A $8,179.20 O&M
SI1 N/A 300 Suite Kitchen Beige Sink
Undercoating 1 EA No Good PACM N/A $307.40 O&M
PL3 N/A
3rd fl. Hallway, 2nd fl.
Hallway, 2nd fl.
Stairwell Lobby/Elevator
Lobby, Lobby outside Rm. 207, 1st fl.
Security Station, 1st fl.
Hallway, Suite 103 Lunch Room, 1st fl.
Old Courtroom
Decorative Plaster 1,026 SF No Good PACM N/A $10,218.96 O&M
Material
Description Quantity Friable Condition Results
Quantity of
Damage
Estimated Abatement
Costs
Recommended Response
Action
FD1 N/A
3rd fl. Elevator Lobby, 2nd fl. Elevator Lobby, 1st fl. Elevator Lobby, Basement Telephone
Closet, Basement Electrical Closet, Chiller Room
Fire Door 14 EA No Good PACM N/A $4,303.60 O&M
VT1 N/A 300 Suite Kitchen
12”x12” White Floor Tile with Grey
Streaks and Associated Mastic
72 SF No Good PACM N/A $200.16 O&M
VT2 N/A
Suite 206 Judges’ Chamber Kitchen
12”x12” White Floor Tile with Multi Different Color
Streaks and Associated Mastic
221 SF No Good PACM N/A $614.38 O&M
VT3 N/A
Basement Hallway by Holding Cell (Cage Room), Pipe Room, Basement Storage
Room, Basement Back Hallway, Basement
Main Hallway, Hallway outside large
Storage Room
12”x12” Beige Mottled Floor Tile and Associated Mastic
1,964 SF No Good PACM N/A $5,459.92 O&M
VT4 N/A
Janitorial Storage
Closet
12”x12” Light Grey Floor Tile with Dark
Grey Streaks and Associated Mastic
156 SF No Good PACM N/A $433.68 O&M
VT5 N/A Basement Storage 9”x9” Green Floor Tile underneath the carpet 500 SF No Good PACM N/A $1,390.00 O&M
Material
Description Quantity Friable Condition Results
Quantity of
Damage
Estimated Abatement
Costs
Recommended Response
Action
BBM2 N/A
1st fl. Back Office Suite Hallway, Back Office Suite Office 2, Office3, Clerk Station, Pipe Room, Basement
Storage Room
4” Red Baseboard and Associated
Mastic 378 LF No Good PACM N/A $929.88 O&M
Noise Dampe ner N/A 1st fl. Old Court Room Noise Dampener 800 SF No Good PACM N/A $1,440.00 O&M
Note: Estimated abatement costs are applicable to large scale abatement projects.
Table 3: Estimated Abatement Cost Unit Price Table
RS Means Basis of Abatement Cost
Estimates Cost Per Unit Locality Adjustment
General Conditions Adjustment
Contingency Adjustment
Total Estimated Unit Price
Flooring $2.26 / SF
0.972 1.15 1.1
$2.78 Pipe/Duct Insulation $6.80 / LF $8.36
Pipe Fittings $17.85 / EA $21.95 Caulking $5.35 / LF $6.58
Ceiling Tile / Wall Board $1.46 / SF $1.80 Thermal Insulation $11.40 / SF $14.02 Industry Normal Abatement Cost
Estimates Cost Per Unit Locality Adjustment
General Conditions Adjustment
Contingency Adjustment
Total Estimated Unit Price
Pipe/Duct Mastic $2.00 / LF
0.972 1.15 1.1
$2.46 Baseboard Mastic $2.00 / LF $2.46
Fire Door $250.00 / EA $307.40 Sink Under Coating $250 / EA $307.40 Elevator Brake Pads $20.00 / EA $24.59
Mastic Daubs $2.00 / SF $2.46 Vibration Dampener Cloth $15.00 / EA $18.44
Transite Materials $2.75 / SF $3.38
APPENDIX B
PREVIOUSLY SAMPLED, NON-ASBESTOS
CONTAINING MATERIALS
Table 4: Previously Sampled Non-Asbestos Containing Materials
Homogenous
Area Material Sample Location Color Results Sample Date
BC-101614 Black AHU Wrap Mastic Sealant AHU in Attic Black None Detected 10/16/2014
PL1 Plaster Wall 3rd fl. Mech. Room, 2nd Fl. Mech., 3rd fl. Restroom, 2nd fl. Restroom White None Detected 6/20/2016
PL2 Plaster Ceiling 3rd fl. Mech. Room, 2nd fl. Mech.
Room White None Detected 6/20/2016
CT3
2’x4’ Ceiling Tile with Pinholes and
Fissures
103 Suite Lunch Room, Suite 103
Storage Room, Basement Back
Storage
White None Detected 6/20/2016
BBM1
4” Black Baseboard and Associated
Mastic Rm. 203, 202, 203 Black None Detected 6/20/2016
CM1 Yellow Carpet Mastic
Office Next to Server Room, Computer Storage Room, Server
Room
Yellow None Detected 6/20/2016
APPENDIX C
LABORATORY ANALYTICAL RESULTS FOR
2016 SURVEY
EMSL Analytical, Inc.
10768 Baltimore Avenue Beltsville, MD 20705
Tel/Fax: (301) 937-5700 / (301) 937-5701 http://www.EMSL.com / beltsvillelab@emsl.com
191606873EMSL Order:
Customer ID: ARCE78
Customer PO:
Project ID:
Attention: Phone:Stacy Kahatapitiya (443) 864-7464
Fax:Arc Environmental (410) 962-1065
Received Date:1311 Haubert Street 06/24/2016 1:10 PM
Analysis Date:Baltimore, MD 21230 06/27/2016
Collected Date: 06/20/2016
Project: MARTIN V BOSTTETOR
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
PL1-1-Skim Coat
191606873-0001
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
5%
45%
50%
White
Non-Fibrous
Homogeneous
PLASTER WALL
PL1-1-Rough Coat
191606873-0001A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
18%
Cellulose2%Tan/Various
Fibrous
Homogeneous
PLASTER WALL
PL1-2-Skim Coat
191606873-0002
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
5%
45%
50%
White
Non-Fibrous
Homogeneous
PLASTER WALL
PL1-2-Rough Coat
191606873-0002A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
16%
Cellulose4%Tan/Various
Fibrous
Homogeneous
PLASTER WALL
PL1-3-Skim Coat
191606873-0003
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
5%
45%
50%
White
Non-Fibrous
Homogeneous
PLASTER WALL
PL1-3-Rough Coat
191606873-0003A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
16%
Cellulose4%Tan/Various
Fibrous
Homogeneous
PLASTER WALL
PL1-4-Skim Coat
191606873-0004
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
5%
45%
50%
White
Non-Fibrous
Homogeneous
PLASTER WALL
PL1-4-Rough Coat
191606873-0004A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
17%
Cellulose3%Tan/Various
Fibrous
Homogeneous
PLASTER WALL
PL1-5-Skim Coat
191606873-0005
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
5%
45%
50%
White
Non-Fibrous
Homogeneous
PLASTER WALL
PL1-5-Rough Coat
191606873-0005A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
18%
Cellulose2%Tan/Various
Fibrous
Homogeneous
PLASTER WALL
PL1-6-Skim Coat
191606873-0006
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
5%
45%
50%
White
Non-Fibrous
Homogeneous
PLASTER WALL
PL1-6-Rough Coat
191606873-0006A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
17%
Cellulose3%Tan/Various
Fibrous
Homogeneous
PLASTER WALL
PL1-7-Skim Coat
191606873-0007
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
5%
45%
50%
White
Non-Fibrous
Homogeneous
PLASTER WALL
PL1-7-Rough Coat
191606873-0007A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
16%
Cellulose4%Tan/Various
Fibrous
Homogeneous
PLASTER WALL
PL2-8-Skim Coat
191606873-0008
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
5%
45%
50%
White
Non-Fibrous
Homogeneous
PLASTER CEILING
PL2-8-Rough Coat
191606873-0008A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
17%
Cellulose3%Tan/Various
Fibrous
Homogeneous
PLASTER CEILING
Initial Report From: 06/28/2016 10:46:44
Page 1 of 3ASB_PLM_0008 - 1.71 Printed: 6/28/2016 10:46 AM
Tel/Fax: (301) 937-5700 / (301) 937-5701 http://www.EMSL.com / beltsvillelab@emsl.com
191606873EMSL Order:
Customer ID: ARCE78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
PL2-9-Skim Coat
191606873-0009
Insufficient MaterialPLASTER CEILING
PL2-9-Rough Coat
191606873-0009A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
17%
Cellulose3%Tan/Various
Fibrous
Homogeneous
PLASTER CEILING
PL2-10-Skim Coat
191606873-0010
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
5%
45%
50%
White
Non-Fibrous
Homogeneous
PLASTER CEILING
PL2-10-Rough Coat
191606873-0010A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
16%
Cellulose4%Tan/Various
Fibrous
Homogeneous
PLASTER CEILING
PL2-11-Skim Coat
191606873-0011
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
5%
45%
50%
White
Non-Fibrous
Homogeneous
PLASTER CEILING
PL2-11-Rough Coat
191606873-0011A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
18%
Cellulose2%Tan/Various
Fibrous
Homogeneous
PLASTER CEILING
PL2-12-Skim Coat
191606873-0012
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
5%
45%
50%
White
Non-Fibrous
Homogeneous
PLASTER CEILING
PL2-12-Rough Coat
191606873-0012A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
17%
Cellulose3%Tan/Various
Fibrous
Homogeneous
PLASTER CEILING
PL2-13-Skim Coat
191606873-0013
Insufficient MaterialPLASTER CEILING
PL2-13-Rough Coat
191606873-0013A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
16%
Cellulose4%Tan/Various
Fibrous
Homogeneous
PLASTER CEILING
PL2-14-Skim Coat
191606873-0014
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
5%
45%
50%
White
Non-Fibrous
Homogeneous
PLASTER CEILING
PL2-14-Rough Coat
191606873-0014A
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
60%
20%
17%
Cellulose3%Tan/Various
Fibrous
Homogeneous
PLASTER CEILING
CT3-15
191606873-0015
None DetectedPerlite
Non-fibrous (Other)
35%
10%
Cellulose
Min. Wool
30%
25%
Gray/White
Fibrous
Heterogeneous
2X4 FISSURED &
PINHOLE CEILING
TILE
CT3-16
191606873-0016
None DetectedPerlite
Non-fibrous (Other)
35%
10%
Cellulose
Min. Wool
30%
25%
Gray/White
Fibrous
Heterogeneous
2X4 FISSURED &
PINHOLE CEILING
TILE
CT3-17
191606873-0017
None DetectedPerlite
Non-fibrous (Other)
35%
10%
Cellulose
Min. Wool
30%
25%
Gray/White
Fibrous
Heterogeneous
2X4 FISSURED &
PINHOLE CEILING
TILE
DM1-18
191606873-0018
None DetectedCa Carbonate
Non-fibrous (Other)
30%
70%
Gray
Non-Fibrous
Homogeneous
DUCT SEAM
SEALANT ON BARE
METAL DUCT
DM1-19
191606873-0019
None DetectedCa Carbonate
Non-fibrous (Other)
30%
70%
Gray
Non-Fibrous
Homogeneous
DUCT SEAM
SEALANT ON BARE
METAL DUCT
DM1-20
191606873-0020
None DetectedCa Carbonate
Non-fibrous (Other)
30%
70%
Gray
Non-Fibrous
Homogeneous
DUCT SEAM
SEALANT ON BARE
METAL DUCT
BBM1-21-Cove Base
191606873-0021
None DetectedCa Carbonate
Non-fibrous (Other)
45%
55%
Gray/Black
Non-Fibrous
Heterogeneous
4" BLK.
BASEBOARD &
MASTIC
Page 2 of 3ASB_PLM_0008 - 1.71 Printed: 6/28/2016 10:46 AM
Tel/Fax: (301) 937-5700 / (301) 937-5701 http://www.EMSL.com / beltsvillelab@emsl.com
191606873EMSL Order:
Customer ID: ARCE78
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
BBM1-21-Mastic
191606873-0021A
None DetectedNon-fibrous (Other)100%Brown/Yellow
Non-Fibrous
Heterogeneous
4" BLK.
BASEBOARD &
MASTIC
BBM1-22-Cove Base
191606873-0022
None DetectedCa Carbonate
Non-fibrous (Other)
45%
55%
Gray/Black
Non-Fibrous
Heterogeneous
4" BLK.
BASEBOARD &
MASTIC
BBM1-22-Mastic
191606873-0022A
None DetectedNon-fibrous (Other)100%Brown/Yellow
Non-Fibrous
Heterogeneous
4" BLK.
BASEBOARD &
MASTIC
BBM1-23-Cove Base
191606873-0023
None DetectedCa Carbonate
Non-fibrous (Other)
45%
55%
Gray/Black
Non-Fibrous
Heterogeneous
4" BLK.
BASEBOARD &
MASTIC
BBM1-23-Mastic
191606873-0023A
None DetectedNon-fibrous (Other)100%Brown/Yellow
Non-Fibrous
Heterogeneous
4" BLK.
BASEBOARD &
MASTIC
CM1-27
191606873-0024
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
CARPET MASTIC
CM1-28
191606873-0025
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
CARPET MASTIC
CM1-29
191606873-0026
None DetectedNon-fibrous (Other)100%Yellow
Non-Fibrous
Homogeneous
CARPET MASTIC
Analyst(s)
William Chrobak (41) Joe Centifonti, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Beltsville, MD NVLAP Lab Code 200293-0
Page 3 of 3ASB_PLM_0008 - 1.71 Printed: 6/28/2016 10:46 AM
OrderID: 191606873
OrderID: 191606873
APPENDIX D
GSA INSPECTION FORMS
Asbestos Assessment Data Form
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): _159 LF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______DIM1__________________
(Assign HSA Number)
HSA DESCRIPTION: __Black Mastic on Duct Insulation Wrap _______
LOCATION(S) OF HSA IN BLDG: ____Attic ___
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material __ Significant _ High
_ Thermal Systems Insulation _X Minor __ Medium
_X Miscellaneous Material _ None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
__ High _ High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _X Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____1_____
Sample Number Sample Location Result
(Include percent and type of asbestos in result, e.g. 50% Chrysotile)
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and definitions.
BC‐101614‐02A Attic 6% Chrysotile
BC‐101614‐02B Attic Not Analyzed, Positive Stop
BC‐101614‐02C Attic Not Analyzed, Positive Stop
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): _82 LF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______DIM2__________________
(Assign HSA Number)
HSA DESCRIPTION: __Beige Seam Sealant Mastic on Foil Duct Wrap _______
LOCATION(S) OF HSA IN BLDG: ____Attic, 3rd Fl. Mech. Room ___
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material __ Significant _ High
_ Thermal Systems Insulation _X Minor __ Medium
_X Miscellaneous Material _ None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
__ High _ High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _X Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____1_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): _30 LF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______DIM3__________________
(Assign HSA Number)
HSA DESCRIPTION: __Black Seam Sealant Mastic on Foil Duct Wrap _______
LOCATION(S) OF HSA IN BLDG: ____Attic, 2nd Fl. Mech. Room ___
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material __ Significant _ High
_ Thermal Systems Insulation _X Minor __ Medium
_X Miscellaneous Material _ None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
__ High _ High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _X Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____1_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): _52 LF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______DI1 _________________
(Assign HSA Number)
HSA DESCRIPTION: _Duct Insulation _ _______
LOCATION(S) OF HSA IN BLDG: ____Chiller Room ___
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material __ Significant _ High
X Thermal Systems Insulation _ Minor __ Medium
_ Miscellaneous Material _X None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_X High _ High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_ Low _X Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): _5 EA__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______Fit1__________________
(Assign HSA Number)
HSA DESCRIPTION: __Mudded Fitting _______
LOCATION(S) OF HSA IN BLDG: ____Attic, 3rd Fl. Mech. Room ___
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material _X Significant _ High
X Thermal Systems Insulation _ Minor __ Medium
_ Miscellaneous Material _ None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_X High _ High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_ Low _X Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____1_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
BC‐101614‐04A Attic 20% Chrysotile
BC‐101614‐04B Attic Not Analyzed, Positive Stop
BC‐101614‐04C Attic Not Analyzed, Positive Stop
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): _235 LF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______PI1__________________
(Assign HSA Number)
HSA DESCRIPTION: _Cork Pipe Insulation with Black Mastic _______
LOCATION(S) OF HSA IN BLDG: ____Attic, 2nd Fl. Mech. Room ___
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material _ Significant _ High
X Thermal Systems Insulation _ Minor __ Medium
_ Miscellaneous Material _X None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_ High _ High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _X Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): _10 LF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______PI2__________________
(Assign HSA Number)
HSA DESCRIPTION: __Mudded Pipe Insulation _______
LOCATION(S) OF HSA IN BLDG: ___3rd Fl. Mech. Room ___
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material _ Significant _ High
X Thermal Systems Insulation _ Minor __ Medium
_ Miscellaneous Material _X None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_X High _ High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_ Low _X Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 1,601 LF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______PIM1__________________
(Assign HSA Number)
HSA DESCRIPTION: __White Pipe Seam Sealant Mastic _______
LOCATION(S) OF HSA IN BLDG: __Attic, Basement Custodial Office, Pump Room, Hallway by Old Holding Cell (Cage Room), Pipe
Room, Telephone Closet 1, Electrical Closet, B13 Mech. Room, Basement Main Hallway, Chiller Room, Large Storage Room, Computer Storage Room, Server Room, Office next to Server Room, Janitorial Storage Closet __
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material __ Significant _ High
_ Thermal Systems Insulation _X Minor __ Medium
_X Miscellaneous Material _ None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
__ High _ High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _X Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_______
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 64 LF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______PIM2__________________
(Assign HSA Number)
HSA DESCRIPTION: __Black Mastic on Pipe Wrap _______
LOCATION(S) OF HSA IN BLDG: __Attic __
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material __ Significant _ High
_ Thermal Systems Insulation _ Minor __ Medium
_X Miscellaneous Material _X None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
__ High _ High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _X Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 18 LF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______PIW1_________________
(Assign HSA Number)
HSA DESCRIPTION: __Paper Pipe Wrap with Foil Backing and Black Mastic _______
LOCATION(S) OF HSA IN BLDG: __Attic __
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material __ Significant _ High
_ Thermal Systems Insulation _ Minor __ Medium
_X Miscellaneous Material _X None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
__ High _ High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _X Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 26 LF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______VC1_________________
(Assign HSA Number)
HSA DESCRIPTION: __Canvas Vibration Collar _______
LOCATION(S) OF HSA IN BLDG: __Attic __
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material __ Significant _ High
_ Thermal Systems Insulation _X Minor __ Medium
_X Miscellaneous Material _ None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
__ High _ High _X High __ High
__ Medium __ Medium _ Medium __ Medium
_X Low _X Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
BC‐101614‐01A Attic 60% Chrysotile
BC‐101614‐01B Attic Not Analyzed, Positive Stop
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 3,934 SF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______TZ1_______________
(Assign HSA Number)
HSA DESCRIPTION: __Brown, Grey and Beige Stone Design Terrazzo ______
LOCATION(S) OF HSA IN BLDG: __ 3rd fl. Stairwell/Elevator Lobby, 2nd fl. Stairwell/Elevator Lobby, Men’s Restrooms, Women’s
Restroom, 3rd fl. Mech. Room, 1st fl. Security Station, 1st fl. Hallway, Basement Restroom __
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material __ Significant _X High
_ Thermal Systems Insulation _ Minor __ Medium
_X Miscellaneous Material _X None _ Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
__ High _X High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _ Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 1,302 SF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______CT1______________
(Assign HSA Number)
HSA DESCRIPTION: __1’x1’ Ceiling Tile with Fissure and Associated Mastic Daub ______
LOCATION(S) OF HSA IN BLDG: __ Courtroom 3 __
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material __ Significant _ High
_ Thermal Systems Insulation _ Minor __ Medium
_X Miscellaneous Material _X None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_X High _ High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_ Low _ X Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 4,544 SF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______CT2______________
(Assign HSA Number)
HSA DESCRIPTION: __2’x2’ Ceiling Tile with Pinholes and Divots ______
LOCATION(S) OF HSA IN BLDG: _ Throughout the Building __
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material __ Significant _ High
_ Thermal Systems Insulation _ Minor __ Medium
_X Miscellaneous Material _X None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_X High _X High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_ Low _ Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 1 EA__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______SI1______________
(Assign HSA Number)
HSA DESCRIPTION: __Beige Sink Undercoating ______
LOCATION(S) OF HSA IN BLDG: _ 300 Suite Kitchen __
(Include Functional Space)
HSA Category Damage Accessibility
__ Surfacing Material __ Significant _ High
_ Thermal Systems Insulation _ Minor __ Medium
_X Miscellaneous Material _X None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_ High _ High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _ X Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 1,026 SF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______PL3______________
(Assign HSA Number)
HSA DESCRIPTION: __Decorative Plaster ______
LOCATION(S) OF HSA IN BLDG: _ 3rd fl. Hallway, 2nd fl. Hallway, 2nd fl. Stairwell Lobby/Elevator Lobby, Lobby outside Rm. 207, 1st
fl. Security Station, 1st fl. Hallway, Suite 103 Lunch Room, 1st fl. Old Courtroom __
(Include Functional Space)
HSA Category Damage Accessibility
_X Surfacing Material __ Significant _ High
_ Thermal Systems Insulation _ Minor __ Medium
_ Miscellaneous Material _X None _X Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_ High _X High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _ Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 14 EA__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______FD1____________
(Assign HSA Number)
HSA DESCRIPTION: __Fire Door ______
LOCATION(S) OF HSA IN BLDG: _ 3rd fl. Elevator Lobby, 2nd fl. Elevator Lobby, 1st fl. Elevator Lobby, Basement Telephone
Closet, Basement Electrical Closet, Chiller Room __
(Include Functional Space)
HSA Category Damage Accessibility
_ Surfacing Material __ Significant _X High
_ Thermal Systems Insulation _ Minor __ Medium
_X Miscellaneous Material _X None _ Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_ High _X High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _ Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 72 SF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______VT1____________
(Assign HSA Number)
HSA DESCRIPTION: _12”x12” White Floor Tile with Grey Streaks and Associated Mastic ______
LOCATION(S) OF HSA IN BLDG: _ 300 Suite Kitchen __
(Include Functional Space)
HSA Category Damage Accessibility
_ Surfacing Material __ Significant _X High
_ Thermal Systems Insulation _ Minor __ Medium
_X Miscellaneous Material _X None _ Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_ High _X High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _ Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 221 SF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______VT2____________
(Assign HSA Number)
HSA DESCRIPTION: _12”x12” White Floor Tile with Multi Color Streaks and Associated Mastic ______
LOCATION(S) OF HSA IN BLDG: _ Suite 206 Judges’ Chamber Kitchen __
(Include Functional Space)
HSA Category Damage Accessibility
_ Surfacing Material __ Significant _X High
_ Thermal Systems Insulation _ Minor __ Medium
_X Miscellaneous Material _X None _ Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_ High _X High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _ Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 1,964 SF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______VT3____________
(Assign HSA Number)
HSA DESCRIPTION: _12”x12” Beige Mottled Floor Tile and Associated Mastic ______
LOCATION(S) OF HSA IN BLDG: _ Basement Hallway by Holding Cell (Cage Room), Pipe Room, Basement Storage Room, Basement Back Hallway, Basement Main Hallway, Hallway outside large Storage Room __
(Include Functional Space)
HSA Category Damage Accessibility
_ Surfacing Material __ Significant _X High
_ Thermal Systems Insulation _ Minor __ Medium
_X Miscellaneous Material _X None _ Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_ High _X High __ High __ High
__ Medium __ Medium _X Medium __ Medium
_X Low _ Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 156 SF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______VT4____________
(Assign HSA Number)
HSA DESCRIPTION: _12”x12” Light Grey Floor Tile with Dark Grey Streaks and Associated Mastic __
LOCATION(S) OF HSA IN BLDG: _ Janitorial Storage Closet __
(Include Functional Space)
HSA Category Damage Accessibility
_ Surfacing Material __ Significant _X High
_ Thermal Systems Insulation _ Minor __ Medium
_X Miscellaneous Material _X None _ Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_ High _ High __ High __ High
__ Medium _X Medium _X Medium __ Medium
_X Low _ Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 500 SF__
ASBESTOS INSPECTOR: __Derek Kwon ______________________________________________________________
HOMOGENOUS SAMPLING AREA #: ______VT5____________
(Assign HSA Number)
HSA DESCRIPTION: _9”x9” Green Floor Tile and Associated Mastic under the carpet ______
LOCATION(S) OF HSA IN BLDG: _ Basement Storage Room __
(Include Functional Space)
HSA Category Damage Accessibility
_ Surfacing Material __ Significant _X High
_ Thermal Systems Insulation _ Minor __ Medium
_X Miscellaneous Material _X None _ Low
Air Plenum __
(Y or N)
Friability Traffic Vibration Potential for Air Erosion
_ High _ High __ High __ High
__ Medium _X Medium _X Medium __ Medium
_X Low _ Low __ Low _X Low
Comments:_________________________________________________________________________________________
AHERA Classification (see instructions): ____5_____
NOTE: Use one form per homogeneous sampling area. Consult 40 CFR Part 763 for sampling and analytical protocols and
Bldg. Name: _Martin V Bostetter Courthouse_ ASSESSMENT DATE: _6/20/2016_____
Address: _200 South Washington St. Alexandria, VA_
GSA BLDG. NO.: _VA0003ZZ_______ AMOUNTS (S.F./L.F./CU.F.): 378 LF__