This solicitation package describes a federal contract opportunity to improve a sub-specialty waiting area at the Dayton VA Medical Center in Ohio. The project scope involves fully renovating approximately 4,000 square feet on the first floor of Building 310, including creating 10 new exam rooms in an adjoining unfinished area of around 2,080 square feet. Additional areas will receive new finishes and plumbing, and approximately 27 existing exam rooms will be upgraded with new sinks and fire alarm and nurse call systems. Corridors in the scope area will be abated and receive finish upgrades, and most areas will get new LED light fixtures. The contract is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses, with a minimum of 15% self-performance required. The estimated value is between $2-5 million. The solicitation will be posted on July 29th, with bid opening approximately 30 days later. The duration shall not exceed 220 calendar days from notice to proceed. Bonds, insurance and security requirements apply. The Department of Veterans Affairs is the contracting agency.
View the file
Other files
Show 40 more
Latest 50 of 75 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CAST RM.
1E-115C
EXAM
1E-115D
EXAM
1E-115E
EXAM
1E-115F
EXAM
1E-116
STORAGE RM.
1E-115B
EXAM
1E-115A
EXAM
1E-115
EXAM
1E-114
EXAM
1E-113
VITALS
1E-117
EXAM
1E-118
EXAM
1E-119
EXAM
1E-120
TOILET
1E-123
EXAM
1E-121
EXAM
1E-122
PHOTO -THERAPY
1E-160D
EXAM
1E-124
EXAM
1E-126
EXAM 8
1E-127
EXAM 7
1E-128
TECHICIAN 6
1E-129
EXAM 5
1E-130
EXAM 4
1E-131
EXAM 3
1E-132
EXAM 2
1E-133
EXAM 1
1E-134
EXAM 1a
1E-134A
TOILET
1E-136H
STORAGE
1E-136G
EXAM
1E-136C
EXAM
1E-136D
EXAM
1E-136E
EXAM
1E-136F
TELE/CLOSET
1E-175
STAIRS
SWD
RELEASE OF
INFORMATION
1E-174
CHECK-IN
1E-170e
PRINTER / COPY
SUPERVISOR
1E-170d
OFFICE
1E-170c
OFFICE
1E-170b
OFFICE
1E-170a
STEAM MECH RM.
1E-171
STAIRS
SWF
TRAVEL AND
ELIGIBILITY
1E-170
WAITING AREA
1E-135
CHECK-IN 1E-142
AGENT CASHIER
1E-173
OFFICE
1E-173a
WORKROOM
1E-143
CHECK OUT
C1-21A
VITALS
C1-21
ELEVATOR
ELEVATOR
TELE/DATA
CLOSET
1E-172
TRAVEL OFFICE
1E-146
EXAM ROOM
1E-109a
EXAM ROOM
1E-109b
EXAM ROOM
1E-109c
EXAM ROOM
1E-109e
EXAM ROOM
1E-109d
ELECT. RM
1E-147
EXAM
1E-148
EXAM
1E-150
EXAM
1E-152
EXAM
1E-153
EXAM
1E-154
EXAM
1E-155
MENS
1E-158A
OUTPATIENT
NURSE MGR.
1E-161
CLEAN UTILITY
1E-162
EXAM
1E-163
EXAM
1E-164
EXAM
1E-165
EXAM
1E-166
EXAM
1E-167
EXAM
1E-168
SOILED UTILITY
1E-159
NURSE CHECK-IN
1E-160
EXAM
1E-160A
EXAM
1E-160B
EXAM
1E-160C
EXAM
1E-124A
EXAM
1E-124B
EXAM
1E-124C
TELE CLOSET
1E-176
EXAM
1E-104
EXAM
1E-105
EXAM
1E-106
ONCOLOGY
1E-156
HAC
1E-157
WOMENS
1E-158
EXAM
1E-109
EXAM /
EDUCATION
1E-109A
OFFICE
1E-109B
EXAM
1E-110
ORTHOPEDIC
1E-111
STOR
1E-111A
BREAK RM.
1E-112
STAFF LOUNGE
1E-112A
OUTPATIENT
WAITING AREA
C1-13
STAIRS
SWC
CORRIDOR
C1-31
CORRIDOR
C1-2C
C O
R R
I D
O R
CORRIDOR
C1-19
C O
R R
I D
O R
C
CORRIDOR
C1-6
CORRIDORC1-24
CORRIDOR
C1-25
C O
R R
I D
O R
C
CORRIDOR
C1-9
CORRIDOR
C1-11
CORRIDOR
C1-15
CORRIDOR
C1-12
CORRIDOR
C1-28
COMM
1E-107A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Architecture Engineering Design-Build paradigm
AutoCAD SHX Text
SWB
AutoCAD SHX Text
DN.
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN.
AutoCAD SHX Text
UP
AutoCAD SHX Text
RAMP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text 1A-100
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN.
AutoCAD SHX Text
UP
AutoCAD SHX Text
FEC EX.
AutoCAD SHX Text
FEC EX.
AutoCAD SHX Text
FEC EX.
AutoCAD SHX Text
FEC EX.
AutoCAD SHX Text
FEC
AutoCAD SHX Text
FEC EX.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TU-1
AutoCAD SHX Text
TU-2
AutoCAD SHX Text
TU-3
AutoCAD SHX Text
TU-4
AutoCAD SHX Text
TU-5
AutoCAD SHX Text
TU-6
AutoCAD SHX Text
TU-7
AutoCAD SHX Text
TU-8
AutoCAD SHX Text
TU-9
AutoCAD SHX Text
TU-10
AutoCAD SHX Text
TU-11
AutoCAD SHX Text
TU-12
AutoCAD SHX Text
TU-13
AutoCAD SHX Text 200 Envoy Circle, Suite 201, Louisville, KY 40299 www.paradigmusa.com
AutoCAD SHX Text
BID DOCUMENTS FOR CONSTRUCTION
AutoCAD SHX Text
FULLY SPRINKLERED
AutoCAD SHX Text
IMPROVE SUB-SPECIALTY WAITING AREA B310
AutoCAD SHX Text 552-19-103
AutoCAD SHX Text 03-20-2020
AutoCAD SHX Text
4100 W THIRD ST, DAYTON, OH 45428
AutoCAD SHX Text
DAYTON VA MEDICAL CENTER
AutoCAD SHX Text
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text C
AutoCAD SHX Text A
AutoCAD SHX Text F
AutoCAD SHX Text I
AutoCAD SHX Text Exp. 6-30-21
AutoCAD SHX Text No. M 35425
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text D
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text H
AutoCAD SHX Text L.
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text MECHANICAL PIPING GENERAL NOTES A. REFER TO DWG. M-001 FOR MECHANICAL ABBREVIATIONS, SYMBOLS, REFER TO DWG. M-001 FOR MECHANICAL ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES RELATED TO THIS SHEET. B. ALL EXISTING PIPING, DUCTWORK, SPRINKLERS, CONDUIT, LIGHTING ALL EXISTING PIPING, DUCTWORK, SPRINKLERS, CONDUIT, LIGHTING OR OTHER CONSTRUCTION SHALL BE RELOCATED AS REQUIRED FOR ALL DEMOLITION AND INSTALLATION WORK. C. COMPLETE LAYOUT DRAWINGS SHALL BE REQUIRED BY PARAGRAPH COMPLETE LAYOUT DRAWINGS SHALL BE REQUIRED BY PARAGRAPH 1.4 SUBMITTALS OF ALL SPECIFICATION SECTIONS. CONSTRUCTION WORK SHALL NOT START ON ANY SYSTEM UNTIL THE LAYOUT DRAWINGS HAVE BEEN APPROVED. D. REFER TO MH104 FOR MECHANICAL HVAC PLAN. REFER TO MH104 FOR MECHANICAL HVAC PLAN. E. ALL PIPES SHALL BE A MINIMUM OF 3/4". PIPE BRANCHES TO ALL PIPES SHALL BE A MINIMUM OF 3/4". PIPE BRANCHES TO TERMINAL UNITS PER THE AIR TERMINAL UNITS SIZING SCHEDULE. F. NOT ALL OFFSETS ARE SHOWN. CONTRACTOR SHALL MAKE NOT ALL OFFSETS ARE SHOWN. CONTRACTOR SHALL MAKE MODIFICATIONS TO LAYOUT TO COORDINATE WITH EXISTING TRUSSES, CATWALKS, MECHANICAL ROOM FLOORS AND OTHER DUCTS, PIPING AND ELECTRICAL WORK WITHIN THE SPACE.
AutoCAD SHX Text
MECHANICAL PIPING PLAN FIRST FLOOR
AutoCAD SHX Text
MP101
AutoCAD SHX Text
SCALE 1/8'' = 1'-0''
AutoCAD SHX Text F3
AutoCAD SHX Text
MECHANICAL PIPING PLAN FIRST FLOOR
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text M
AutoCAD SHX Text L
AutoCAD SHX Text K
AutoCAD SHX Text J
AutoCAD SHX Text H
AutoCAD SHX Text G
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DH
AutoCAD SHX Text
RN
| Sheets and Views |
| MP101 |
File details come from the government source that posted it. Updated .