6670-AS301 EXTERIOR ELEVATIONS-EXTERIOR ELEVATIONS.pdf
PDF 658 KB Posted
- Solicitation number
- 36C77623R0050
About this file
This document contains exterior elevation drawings and specifications for a Women's Health Clinic project at the Manchester VAMC. The drawings depict the building materials and colors to be used, including face brick to match the existing CSB building, precast bands and sills, fiber cement panels and vertical and horizontal metal panels to match the existing Clinical Offices building. Other materials specified are 6-inch brake metal trim, aluminum fixed windows, granite sill, and exposed foundation. Notes provide requirements for material samples, sealant colors, and painting exposed elements.
The related federal contract opportunity is solicitation number 36C77623R0050 for construction of the 608-317 Women's Health Clinic at the Manchester VAMC. The solicitation is of type DBB issued by the Department of Veterans Affairs Technology Acquisition Center Austin.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
431 2 5
2B
2D 4A
6A
TYP.TYP.
4B
TYP.
2A
FIRST FLOOR
0'-0" (367.0')
BASEMENT
-12'-0" (355.0')
ROOF LEVEL
12'-0" (379.0')
3C
3A
CROSS-BRACING
BEYOND, RE:
STRUCT. DWGS
3B
4A
4B
2C
2A TOOTH TO
EXISTING
AS302
TYP.
BASIS OF DESIGN:
MORIN "MATRIX" 1.0 PANELS
1-1/2" x 12" VERTICAL (OR
APPROVED EQUAL)
TO MATCH EXISTING
MANCHESTER VAMC
CLINICAL OFFICES BLDG.
D C A
FIRST FLOOR
0'-0" (367.0')
BASEMENT
-12'-0" (355.0')
ROOF LEVEL
12'-0" (379.0')
1A
2A
2B
3B
4A 7A
3A
TYP.
TYP.
TYP.
DECORATIVE RAILING
CONCRETE WALL
GUARDRAIL
AS302
AS302
C.1 D
1A
2A
2B
FIRST FLOOR
0'-0" (367.0')
BASEMENT
-12'-0" (355.0')
ROOF LEVEL
12'-0" (379.0')
3A
3B
PRE-FAB.
POST-SUPPORTED
CANOPY
DECORATIVE
RAILING
CONCRETE WALL
AS302
Scale:
SOUTH EXTERIOR ELEVATION
AS301
1/8"=1'-0"
Scale:
EAST EXTERIOR ELEVATION
AS301
1/8"=1'-0"Scale:
WEST EXTERIOR ELEVATION
AS301
1/8"=1'-0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 -
BID DOCUMENTS
Office of
Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Architectural Design Consultant:
16 JULY 2023Revisions: Date:
608-317
718 SMYTH RD, MANCHESTER, NH
WOMEN'S HEALTH
CLINIC
Approved: Project Director
Approved: Assoc Project Director
Approved: Chief Engineer
Approved: Safety Manager
Approved: NAL
Approved: PCC/Service Director
TAD JRB, MD
T: 401-272-1730 F: 401-273-7156 E-mail: rgbinfo@rgb.net
The Robinson Green Beretta Corporation
Architecture · Project Management · Interior Design
50 Holden Street Providence, RI 02908TRUE N
ORTH
PROJECT NORTH AS301
EXTERIOR
ELEVATIONS
EXTERIOR ELEVATIONS MATERIALS & COLOR SCHEDULE
MATERIAL / DESCRIPTIONITEM
METAL FASCIA
1. NOT ALL EXTERIOR WALL PENETRATIONS, ITEMS, &/or COMPONENTS MAY BE INDICATED &/or SHOWN. RE: ALL DRAWINGS INCLUDING THE PLUMBING, MECHANICAL, ELECTRICAL DRAWINGS.
2. NOT ALL EXTERIOR WALL ELEVATIONS MAY BE SHOWN. COORDINATE w/ PLANS
AND SECTIONS FOR ADDITIONAL EXTERIOR WORK. MATERIALS AND TEXTURES
ARE CONTINUOUS IN AREAS WHERE WALL MAY BE CONCEALED BY OTHER
BUILDING PROJECTIONS.
3. SUBMIT SAMPLES OF ALL EXTERIOR FINISH MATERIALS FOR REVIEW & APPROVAL
PRIOR TO FABRICATING/CONSTRUCTION, TYPICAL.
4. FINISH GRADES SHOWN ARE APPROXIMATE. CONTRACTOR TO REVIEW &
COORDINATE W/ SITE GRADING PLAN.
5. PAINT ALL EXPOSED EXTERIOR GALVANIZED PRIME STEEL LINTELS TO MATCH
ADJACENT EXTERIOR FINISH COLOR, U.N.O.
6. PROVIDE PREFINISHED BACK PLATE @ ALL METAL FASCIA & TRIM JOINTS. BACK
PLATE TO BE 8" MIN. WIDTH.
7. SEALANT/CAULKING COLORS TO MATCH ADJACENT FINISH LISTED IN REQUIRED
PRIORITY. ARCHITECT TO APPROVE SAMPLE IN FIELD PRIOR TO INSTALLATION.
A. SEALANT COLOR @ WINDOWS, STOREFRONT, CURTAIN WALL TO MATCH
FRAME COLOR.
B. SEALANT COLOR @ HOLLOW METAL FRAME TO MATCH FRAME COLOR.
C. SEALANT COLOR @ BRICK TO MATCH BRICK
D. SEALANT COLOR @ SYNTHETIC STONE TO MATCH STONE SYNTHETIC STONE
8. FIELD PAINT RTU TO MATCH ROOF MEMBRANE COLOR
EXTERIOR ELEVATION NOTES:
1A
2B
2D
3A
3B
4A
6B
7A
5A
6A
FACE BRICK, MATCH CSB BUILDING
PRECAST BAND
PRECAST SILL
FIBER-CEMENT PANEL - OPTIMUM BUILDING SYSTEMS LLC OR APPROVED EQUAL.
MATCH EXISTING CLINICAL OFFICES BUILDING MANCHESTER VAMC.
VERTICAL METAL PANEL/ROOF SCREEN SYSTEM
HORIZONTAL METAL PANELOPTIMUM BUILDING SYSTEMS LLC OR APPROVED
EQUAL.MATCH EXISTING CLINICAL OFFICES BUILDING MANCHESTER VAMC.
6" BRAKE METAL TRIM, COLOR: MATCH METAL PANEL
ALUMINUM FIXED WINDOW SYSTEM GRANITE STATE GLASS OR APPROVED
EQUAL.MATCH EXISTING CLINICAL OFFICES BUILDING MANCHESTER VAMC.
SPANDRAL PANEL
CONTROL JOINT
EXPANSION JOINT/COVER
EXPOSED FOUNDATION, RUBBED SMOOTH
2A
2C
3C
4B
LIGHTNING PROTECTION
BLDG 1
BLDG 15
MENTAL
HEALTH
URGENT
CARE
BLDG 18
KEY PLAN
CSB
BLDG
SCOPE
OF WORK
AREA
1 16 JUL 2023
| Sheets and Views |
| EXTERIOR ELEVATIONS |
File details come from the government source that posted it. Updated .