This document contains drawings and technical specifications for telecommunications systems. It details telecommunications symbols and their descriptions for various systems, devices, and components. These include communications outlets, floor boxes, poke-throughs, cable trays, racks, cabling types, speakers, access points, and surveillance equipment. It also provides general notes on diagrammatic representations, device locations, cabling routes, pathway fill capacities, and applicable codes and standards. Relatedly, the federal contract opportunity is a pre-solicitation for repair and equipment upgrade work at a Veterans Affairs medical facility's sterile processing service and equipment area.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ELECTRICAL:
(AFF / AFG UNLESS
NOTED OTHERWISE)
84" 48" 48" 84" 48" 80" 60"
120" 60" 36" 48" 72" 48"
144" 18" 24" 26" 48" 48"
CEILING
48" 48" 18" 84"
AUDIBLE APPLIANCES (CENTERLINE)
ALARMS
ANNUNCIATOR PANELS
CLOCK OUTLETS (CENTERLINE)
CONTROLS (TOP)
EXIT SIGNS (WALL-MOUNTED, BOTTOM)
FIRE ALARM ANNUNCIATOR PANEL (DISPLAY)
FIRE ALARM BELL (EXTERIOR)
FIRE ALARM CONTROL PANEL / UNIT (DISPLAY)
INTERCOM (AREA ONLY)
INTERCOM (TOP)
PANELS & PANELBOARDS (TOP)
PULL STATION (HANDLE)
PHOTOCELLS
RECEPTACLES (BOTTOM)
RECEPTACLES (EXTERIOR)
RECEPTACLES (GARAGES)
RECEPTACLES IN EQUIPMENT ROOMS (TOP)
REMOTE INDICATING LIGHT (EQUIPMENT ROOMS)
REMOTE INDICATING LIGHT (FINISHED AREAS)
SAFETY SWITCHES & STARTERS
SWITCHES (TOP)
TELEPHONE/DATA/TV OUTLETS (BOTTOM)
VISIBLE APPLIANCES (CENTERLINE)
SYMBOL
TELECOMMUNICATIONS SYMBOLS
DESCRIPTION
COMMUNICATIONS OUTLET, TYPE AS NOTED
#D = DATA, # = QUANTITY OF CABLES
#E = ELEVATOR, # = QUANTITY OF CABLES
#FMS = FACILITY MONITORING SYSTEM, # =
QUANTITY OF CABLES
#TV = CABLE TELEVISION, # = QUANTITY OF
CABLES
#V = VOICE, # = QUANTITY OF CABLES
COMMUNICATIONS OUTLET, FLOOR BOX, TYPE AS
NOTED
#D = DATA, # = QUANTITY OF CABLES
#TV = CABLE TELEVISION, # = QUANTITY OF
CABLES
#V = VOICE, # = QUANTITY OF CABLES
MULTI-SERVICE FLOOR BOX / POKE-THRU WITH
POWER / DATA, TYPE AS NOTED AND / OR
SCHEDULED
MULTI-SERVICE POWER POLE WITH POWER / DATA,
TYPE AS NOTED AND / OR SCHEDULED
COMMUNICATIONS OUTLET, CEILING MTD, TYPE AS
NOTED
#D = DATA, # = QUANTITY OF CABLES
#TV = CABLE TELEVISION, # = QUANTITY OF
CABLES
#D/#TV
SERVER RACK, TWO-POST, FLOOR MOUNTED
3/4"x4'x8', FIRE-RATED PLYWOOD BACKBOARD
GROUND BAR, TYPE AS NOTED
SERVER RACK, WALL MOUNTED
CABLE TRAY, TYPE AS NOTED
CABLE TELEVISION LINE
FIBEROPTIC LINE
TELEPHONE LINE
TELEPHONE/DATA LINE
DATA LINE
SPEAKER LINE
INTERCOM LINE
VOLUME CONTROL, WALL MOUNTED
UNDERGROUND COMMUNICATIONS LINE,
CABLING TYPE AS NOTED
SERVER RACK, FOUR-POST, FLOOR MOUNTED
SERVER CABINET, FLOOR MOUNTED
SPEAKER, CEILING MOUNTED, DEPARTMENT
SAFETY PUBLIC ADDRESS SYSTEM
SPEAKER, CEILING MOUNTED, BUILDING PUBLIC
ADDRESS SYSTEM
SPEAKER, WALL MOUNTED
INTERCOM, "M" DENOTES MASTER STATION
CEILING MOUNTED WIRELESS ACCESS POINT,
PROVIDE TWO (2) CAT-6A AT EVERY WAP LOCATION.
CATV
FO
T
T/D
D
S
IC
V
UC
S DS-PA
S B-PA
S
IC
M
WAP
JUNCTION BOXJ
SECURITY SYMBOLS
DOOR AUTO-CLOSER
PANIC / DURESS BUTTON MOUNTED AT 48" A.F.F.
UNLESS NOTED OTHERWISE
ACCESS CONTROL CARD READER WITH KEYPAD
COMBINATION DEVICE
DOOR CONTACT WITH ANTI-PROP/FORCED
ENTRY ALARM
ELECTRIFIED LOCKING DEVICE, LATCH BOLT
MONITOR, AND DOOR POSITION SWITCH
ELECTRIFIED LOCKING DEVICE
INTRUSION DETECTION PASSIVE INFRARED MOTION
DETECTOR - WALL MOUNTED
DOOR AUTO-OPENER
ANTI-PROP DEVICE
REQUEST TO EXIT PUSHBUTTON
DOOR BELL PUSHBUTTON
DOOR CONTACT SWITCH - WIRED TO ACCESS
CONTROL SYSTEM ONLY UNLESS OTHERWISE
NOTED
DELAYED EGRESS
GLASS BREAK DETECTOR
GATE OPENER
INTRUSION DETECTION SYSTEM KEYPAD
RFID KEY TAG READER
MAGNETIC LOCKING DEVICE
SINGLE VIEW SECURITY CAMERA
DUAL VIEW SECURITY CAMERA
180-DEGREE PANORAMIC VIEW SECURITY CAMERA
270-DEGREE PANORAMIC/MULTI-IMAGE VIEW
SECURITY CAMERA
360-DEGREE PANORAMIC/MULTI-IMAGE VIEW
SECURITY CAMERA
SECURITY SURVEILLANCE TELEVISION LINE, MIN. 1"
RACEWAY
DESK MOUNTED RADIO PHONE
RECESSED WALL MOUNTED RADIO PHONE
MOUNTED AT 48" A.F.F. UNLESS NOTED OTHERWISE
SURFACE WALL MOUNTED RADIO PHONE MOUNTED
AT 48" A.F.F. UNLESS NOTED OTHERWISE
VIDEO SURVEILLANCE MONITOR STATION
ELECTRIC POWER TRANSFER
ELECTRIC LATCH RELEASE
AC
AD
AP
CR
RE
DB
DC
DE
DM
EL
EO
GB
GO
KP
KT
MD
ML
PB
SSTV
DR
RR
WR
M
EPT
ELR
DESCRIPTIONSYMBOL
ABBREVIATIONS
EIGHT POSITION, EIGHT CONTACT
ALARM ANNUNCIATOR PANEL
ABOVE FINISHED GRADE
ABOVE FINISHED FLOOR
AUTHORITY HAVING JURISDICTION
THE AMERICAN NATIONAL STANDARDS INSTITUTE
ARCHITECT
BATTERY
BOTTOM OF CABLE TRAY
BUILDING INDUSTRY CONSULTING SERVICE
INTERNATIONAL
8P8C
A
AAP
AFG
AFF
AHJ
ANSI
ARCH
B
BATT
BOCT
BICSI
CONDUIT
C
C
L
LIGHT EMITTING DIODE
LINEAR FEET (FOOT)
LIGHT HAZARD
LOCAL OPERATING CONSOLE
LED
LF
LH
LOC
LOW VOLTAGELV
M
MASTER ANTENNA TELEVISION SYSTEMMATV
MAXIMUMMAX
METAL-CLADMC
MAIN DISTRIBUTION FRAMEMDF
MANHOLEMH
MINIMUMMIN
MOUNTEDMTD
MOUNTINGMTG
N
NOT APPLICABLENA
NATIONAL ELECTRICAL CODENEC
NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NEMA
NATIONAL FIRE PROTECTION ASSOCIATIONNFPA
NOT IN CONTRACTNIC
NOT TO SCALENTS
O
ON CENTEROC
OUTSIDE DIAMETEROD
ORDINARY HAZARDOH
P
PUBLIC ADDRESSPA
PULL CORDPC
POWER OVER ETHERNETPOE
PATCH PANELPP
POWERPWR
R
RCDD
REGISTERED COMMUNICATIONS DISTRIBUTION
DESIGNER
REFLECTED CEILING PLANRCP
RECEPTACLERCPT
RECESSEDREC
REQUIREDREQD
RIGID GALVANIZED STEELRGS
ROOMRM
ROOT MEAN SQUARERMS
RACK UNITRU
S
SUPPLYS
SCHEDULESCHED
SMOKE DETECTORSD
SIMILARSIM
SPEAKERSP
SPECIFICATIONSPEC
SPEAKER/ STROBESP/ST
SQUARESQ
STROBEST
SHIELDED TWISTED PAIRSTP
SURFACESURF
SYSTEMSYST
T
TELECOMMUNICATIONS ENCLOSURETE
TELECOMMUNICATIONS ENCLOSURE FACILITYTEF
TELEPHONETEL
TEMPERATURETEMP
TELECOMMUNICATIONS EQUIPMENT ROOMTER
TELECOMMUNICATIONS GROUNDING BUSSBARTGB
TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION
TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSSBAR
TR TELECOMMUNICATIONS ROOM
TP TWISTED PAIR
TTB TELEPHONE TERMINAL BOARD
TYP TYPICAL
U
UNDERFLOOR DUCTUFD
UNDERGROUNDUGND
UNDERWRITERS LABORATORYUL
UNLESS NOTED OTHERWISEUNO
UNINTERRUPTIBLE POWER SUPPLYUPS
UTILITYUTIL
V
VERTICAL CABLE MANAGERVCM
W
WITHW/
WALL MOUNTEDWM
WITHOUTW/O
X
EXPLOSION PROOFXP
STANDARD MOUNTING HEIGHTS
PROJECT CODES AND STANDARDS
A. VA OFFICE OF INFORMATION & TECHNOLOGY (OIT) DESIGN
GUIDE, FEBRUARY 2011
B. VA OFFICE OF INFORMATION & TECHNOLOGY (OIT)
INFRASTRUCTURE STANDARDS FOR TELECOMMUNICATIONS
SPACES JUNE 1, 2023
C. VA PG-18-10 TELECOMMUNICATIONS AND SPECIAL
TELECOMMUNICATIONS SYSTEMS DESIGN MANUAL, FEBRUARY
D. BICSI AND EIA/TIA STANDARDS AS DEFINED IN VA-18-10
E. VA-PSRDM - PHYSICAL SECURITY AND RESILIENCY DESIGN
MANUAL 2020, 1 JUNE 2023 REVISION
GENERAL NOTES
1. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE
CONSTRUED AS ALL INCLUSIVE; FIELD VERIFY EXISTING
CONDITIONS AND ADJUST WORK AS REQUIRED TO EXECUTE
SPECIFIED WORK.
2. FINAL LOCATION OF ALL DEVICES SHALL BE COORDINATED WITH
FINAL ROOM FURNITURE CONFIGURATIONS, ACCESSORIES,
SPACE INDICATED FOR SPECIFIC DUTY.
3. ALL ICT OUTLETS WITHIN OCCUPIED SPACES SHALL BE LOCATED
WITHIN 18" MAXIMUM FROM AN ELECTRICAL OUTLET; EXCEPTION:
ICT OUTLETS INDICATED FOR SPECIFIC DUTY.
4. ELECTRICAL OUTLETS INDICATED FOR REFERENCE PURPOSES
ONLY; REFER TO ELECTRICAL PLANS FOR ELECTRICAL
REQUIREMENTS.
5. ALL LOCATIONS OF CATV CABLE, TERMINATION AND COMMON
EQUIPMENT TO BE COORDINATED WITH CATV SERVICES
PROVIDER PRIOR TO INSTALLATION.
6. ALL CABLING SHALL BE ROUTED TO AND TERMINATED IN THE
TELECOMMUNICATIONS ROOM.
7. FILL CAPACITIES: CATEGORY FILL CAPACITIES SHALL BE BASED
ON AN O.D. OF .25" OR AN AREA OF .04909 SQ. IN./CABLE;
MAINTAIN A MINIMUM 25% SPARE CAPACITY IN ALL PATHWAYS;
CONDUIT FILL CAPACITIES MAXIMUM FILL = 30%; NON-
CONTINUOUS (J-HOOK) AND CONTINUOUS (CABLE TRAY)
SUPPORTS MAXIMUM FILL = 35.5% FILL (INCLUDING SPARE
CAPACITIES); SLEEVES <24" IN LENGTH MAXIMUM FILL = 75%; IF
CABLE IS PROVIDED WITH LARGER O.D. ADJUST PATHWAYS
ACCORDINGLY, ROUNDED UP TO THE NEXT TRADE SIZE.
8. ALL CABLING SHALL HAVE A MINIMUM 10' SERVICE-LOOP AT THE
COMMUNICATION ROOM.
9. ALL CABLING SHALL HAVE A MINIMUM 3' SERVICE LOOP AT THE
OUTLET OR DEVICE.
10. MOUNTING HEIGHTS FOR DEVICES SHALL BE MEASURED FROM
FINAL FINISH FLOOR TO CENTER OF BOX.
11. VERIFY MOUNTING HEIGHT OF ALL COMMUNICATIONS DEVICES
WITH ARCHITECTURAL ELEVATIONS PRIOR TO ROUGH-IN. WHERE
CONFLICTS EXIST, CONTRACTOR SHALL NOTIFY ENGINEER AND
ARCHITECT FOR RESOLUTION.
12. VERIFY THE LOCATIONS OF ALL FIREPROOFING PRIOR TO THE
INSTALLATION OF CONDUIT AND BACKBOXES.
13. IF FIELD CONDITIONS VARY FROM THE DRAWINGS, THE
CONTRACTOR SHALL DOCUMENT THE VARIATION AND REPORT IT
TO THE GENERAL CONTRACTOR FOR RESOLUTION WITH THE
ENGINEER OF RECORD.
14. COORDINATE THE INSTALLATION REQUIREMENTS OF SYSTEM
DEVICES, EQUIPMENT, PATHWAYS, AND OTHER COMPONENTS
WITH THE GENERAL CONTRACTOR AND OTHER BUILDING TRADES
PRIOR TO INSTALLATION.
15. COORDINATE GROUNDING REQUIREMENTS WITH THE
ELECTRICAL CONTRACTOR AND ENSURE THE COMMUNICATIONS
GROUNDING MEETS SYSTEM REQUIREMENTS AND TIA J-STD-607A
STANDARDS PRIOR TO ENERGIZING AND SYSTEMS EQUIPMENT.
16. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS
SHALL NOT BE SHUTDOWN WITHOUT WRITTEN AUTHORIZATION;
ALL REQUESTS SHALL BE SUBMITTED IN WRITING A MINIMUM OF
TEN (10) WORKING-DAYS PRIOR TO PROPOSED ACTIVITY DATE OR
NEED UNLESS DIRECTED OTHERWISE.
COMMUNITY ANTENNA TELEVISION
CLOSED CIRCUIT TELEVISION
CEILING
CEILING MOUNTED
COMPUTER MACHINE ROOM
COAXIAL CABLE
CATV
CCTV
CLG
CM
CMR
COAX
COMMUNICATIONCOMM
CONTINUE/ CONTINUOUSCONT
CENTERCTR
COPPERCU
D
DECIBEL OR DIRECT BURIALDB
DIRECT CURRENTDC
DEMOLISH/ DEMOLITIONDEMO
DIAMETERDIA
DIMENSIONDIM
DOME LIGHTDL
DRAWINGDWG
E
EACHEA
EXTRA HAZARDEH
ELEVATIONEL
ELEVATORELEV
EMERGENCYEMER
ELECTROMAGNETIC INTERFERENCEEMI
ELECTRICAL METALLIC TUBINGEMT
EQUIPMENTEQUIP
EQUIPMENTEQPM
EXISTING TO REMAINETR
EXISTINGEX
F
FIRE ALARMFA
FINISHED FLOOR ELEVATIONFFE
FLEXIBLE METALLIC CONDUITFLEX
FLOORFLR
FEETFT
FIBER-OPTICFO
G
GAUGEGA
GENERAL CONTRACTORGC
GROUNDGND
H
HORIZONTAL CABLE MANAGERHCM
HEIGHTHGT
HANDHOLEHH
HERTZHZ
I
INSIDE DIAMETERID
INTERMEDIATE DISTRIBUTION FRAMEIDF
INFRAREDIR
J
JUNCTION BOXJB
K
KILOWATTKW
CONTRACTOR PROVIDED, CONTRACTOR INSTALLED.C/C
PLAN LEGEND
DESCRIPTIONSYMBOL
OUT OF SCOPE AREA
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR SBBL COLLABORATIVE JN, INC.
100 N. STONE AVE STE 1102
TUCSON, AZ 85701-1524
(520) 620-0255
NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023
NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024
NM ELEC - EVANS SORDIASHIE #22817 EXP. 12/31/2023
CIVIL / STRUCTURAL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
2519 MADISON AVE
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
HEALTHCARE PLANNER
THE INNOVA GROUP
3196 NORTH SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #: 1993.10
/9
/2
:1
:2
A
M
ABBREVIATIONS, SYMBOLS, LEGENDS,
& NOTES
JPH Drawing # 71 OF 75KGH
BID DOCUMENTS
REPAIR SPS SEWER AND
UPGRADE EQUIPMENT AREA
08/11/2023
501-21-101
RAYMOND G. MURPHY VAMC
1501 SAN PEDRO DRIVE SE
ALBUQUERQUE, NM 87108
T-000
N/A
No. REVISION DESCRIPTION DATE
STAMP:
PA
RK
IN
G
PA
RK
IN
G
PA
RK
IN
G
PA
RK
IN
G
PA
RK
IN
G
M E D
IC
A L
G R O U P
D R
N O R T H
V E T E R A N S
L O O P
R O A D
S U P P O R T
D R
BU
S
ST
OP
SM
OK
IN
G
SH
EL
TE
R
A. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE
CONSTRUED AS ALL INCLUSIVE; REFER TO PERTINENT SPECIFICATION
SECTIONS, FIELD VERIFY EXISTING CONDITIONS AND ADJUST WORK AS
REQUIRED TO EXECUTE SPECIFIED WORK.
B. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD
NOTES AND HISTORICAL DATA AND DOCUMENTATION AND ARE FOR
REFERENCE PURPOSES ONLY TO DEFINE SCOPE OF WORK; FIELD
VERIFY ALL CONDITIONS.
C. ELECTRICAL OUTLET/ DEVICES INDICATED ARE FOR COORDINATION &
REFERENCE PURPOSES; REFER TO ELECTRICAL, E-SERIES DRAWINGS
FOR ELECTRICAL WORK REQUIREMENTS AND SPECIFICATIONS.
D. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS SHALL
NOT BE SHUTDOWN WITHOUT WRITTEN AUTHORIZATION; ALL
REQUESTS SHALL BE SUBMITTED IN WRITING A MINIMUM OF TEN (10)
WORKING-DAYS PRIOR TO PROPOSED ACTIVITY DATE OR NEED
UNLESS DIRECTED OTHERWISE.
E. SEE T-000 ABBREVIATIONS, SYMBOLS, LEGENDS & NOTES FOR
SYMBOLS DEFINITION:
1. SYMBOLS GRAYED/ HALFTONE: INDICATED FOR REFERENCE AND/OR
INDICATING EXISTING UNLESS SPECIFICALLY NOTED OTHERWISE.
2. SYMBOLS DASHED OR SPECIFICALLY KEYED NOTED: INDICATES
DEMOLITION WORK.
F. SECURITY CONTRACTOR SHALL PROVIDE ALL POWER REQUIREMENTS
ASSOCIATED WITH ELECTRONIC SECURITY SYSTEMS.
G. COORDINATE TELECOMMUNICATIONS WORK WITH ALL OTHER
TRADES. VERIFY ALL EXISTING CONDITIONS BEFORE THE START OF
WORK.
H. COORDINATE WORK AND PHASING SCHEDULE WITH THE
CONTRACTING OFFICER'S REPRESENTATIVE.
I. GENERAL CONTRACTOR SHALL PROVIDE HANDHOLES EVERY 400 FEET
MINIMUM.
J. FOR DUCTBANK INFORMATION REFER TO SHEET TY500, DETAIL 12.
TELECOMMUNICATIONS GENERAL NOTES
BUILDING 45
BUILDING 41
B U
IL
D
IN
G
BUILDING 47
TY401
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR SBBL COLLABORATIVE JN, INC.
100 N. STONE AVE STE 1102
TUCSON, AZ 85701-1524
(520) 620-0255
NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023
NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024
NM ELEC - EVANS SORDIASHIE #22817 EXP. 12/31/2023
CIVIL / STRUCTURAL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
2519 MADISON AVE
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
HEALTHCARE PLANNER
THE INNOVA GROUP
3196 NORTH SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #: 1993.10
/9
/2
:1
:2
A
M
ESS SITE PLAN
JPH Drawing # 72 OF 75KGH
BID DOCUMENTS
REPAIR SPS SEWER AND
UPGRADE EQUIPMENT AREA
08/11/2023
501-21-101
RAYMOND G. MURPHY VAMC
1501 SAN PEDRO DRIVE SE
ALBUQUERQUE, NM 87108
TS101
SITE
N
1" = 40'-0"
ESS SITE PLAN1
# TELECOMMUNICATIONS KEYNOTES
1 PROJECT AREA FOR SPS TRAILERS.
S A
N
P
ED
R O
DR
I V E
DR
IV
E
R
I DG
EC RE
ST
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
CR
ML
CR
ML
ML
CR
DM
DM
DM
CR
ML
DM
ML
DM
CR
RE
RE
RE
RE
A. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE
CONSTRUED AS ALL INCLUSIVE; REFER TO PERTINENT SPECIFICATION
SECTIONS, FIELD VERIFY EXISTING CONDITIONS AND ADJUST WORK AS
REQUIRED TO EXECUTE SPECIFIED WORK.
B. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD
NOTES AND HISTORICAL DATA AND DOCUMENTATION AND ARE FOR
REFERENCE PURPOSES ONLY TO DEFINE SCOPE OF WORK; FIELD
VERIFY ALL CONDITIONS.
C. ELECTRICAL OUTLET/ DEVICES INDICATED ARE FOR COORDINATION &
REFERENCE PURPOSES; REFER TO ELECTRICAL, E-SERIES DRAWINGS
FOR ELECTRICAL WORK REQUIREMENTS AND SPECIFICATIONS.
D. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS SHALL
NOT BE SHUTDOWN WITHOUT WRITTEN AUTHORIZATION; ALL
REQUESTS SHALL BE SUBMITTED IN WRITING A MINIMUM OF TEN (10)
WORKING-DAYS PRIOR TO PROPOSED ACTIVITY DATE OR NEED
UNLESS DIRECTED OTHERWISE.
E. SEE T-000 ABBREVIATIONS, SYMBOLS, LEGENDS & NOTES FOR
SYMBOLS DEFINITION:
1. SYMBOLS GRAYED/ HALFTONE: INDICATED FOR REFERENCE AND/OR
INDICATING EXISTING UNLESS SPECIFICALLY NOTED OTHERWISE.
2. SYMBOLS DASHED OR SPECIFICALLY KEYED NOTED: INDICATES
DEMOLITION WORK.
F. SECURITY CONTRACTOR SHALL PROVIDE ALL POWER REQUIREMENTS
ASSOCIATED WITH ELECTRONIC SECURITY SYSTEMS.
G. COORDINATE TELECOMMUNICATIONS WORK WITH ALL OTHER
TRADES. VERIFY ALL EXISTING CONDITIONS BEFORE THE START OF
WORK.
H. COORDINATE WORK AND PHASING SCHEDULE WITH THE
CONTRACTING OFFICER'S REPRESENTATIVE.
I. GENERAL CONTRACTOR SHALL PROVIDE HANDHOLES EVERY 400 FEET
MINIMUM.
J. FOR DUCTBANK INFORMATION REFER TO SHEET TY500, DETAIL 12.
TELECOMMUNICATIONS GENERAL NOTES
RAYMOND G. MURPHY VA
MEDICAL CENTER CAMPUS
N
B45
B41
TY500
TY500
TY500
TY500
H
H
H
H
H H
4 4
H
103A
C-04
C-03
C-01
C-02
B
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
BUILDING 77
BUILDING 45
C-02
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR SBBL COLLABORATIVE JN, INC.
100 N. STONE AVE STE 1102
TUCSON, AZ 85701-1524
(520) 620-0255
NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023
NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024
NM ELEC - EVANS SORDIASHIE #22817 EXP. 12/31/2023
CIVIL / STRUCTURAL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
2519 MADISON AVE
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
HEALTHCARE PLANNER
THE INNOVA GROUP
3196 NORTH SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #: 1993.10
/9
/2
:1
:2
A
M
ESS TEMPORARY SPS TRAILER
ENLARGED PLAN
JPH Drawing # 73 OF 75KGH
BID DOCUMENTS
REPAIR SPS SEWER AND
UPGRADE EQUIPMENT AREA
08/11/2023
501-21-101
RAYMOND G. MURPHY VAMC
1501 SAN PEDRO DRIVE SE
ALBUQUERQUE, NM 87108
TY401
TEMPORARY SPS TRAILERS
1 PROVIDE FIBER OPTIC TERMINATION AND MEDIA CONVERSION. PROVIDE
CATEGORY PATCH CABLING FROM FIBER OPTIC TERMINATION TO VA
PROVIDED AND INSTALLED NETWORK SWITCHES. REFER TO SHEET TY600,
INFRASTRUCTURE RISER DIAGRAM.
2 PROVIDE CATEGORY PATCH CABLING FROM FIBER OPTIC TERMINATION TO
STERIS PROVIDED NETWORK SWITCHES. REFER TO SHEET TY600, RISER 3.
3 PROVIDE THREE (3) 2" CONDUITS WITH INNERDUCT IN CONCRETE ENCASED
DUCTBANK. ONE (1) CONDUIT WITH 12-STRAND SINGLEMODE FIBER
DEDICATED FOR SPS TRAILER TELECOMMUNICATIONS CONNECTIVITY, ONE
(1) CONDUIT WITH MULTI-CONDUCTOR CABLE DEDICATED FOR SITE PACS
HARDWARE, AND ONE (1) SPARE CONDUIT WITH PULLCORD.
4 PROVIDE TRAFFIC RATED HANDHOLE. REFER TO TY500, DETAIL 7.
5 PROVIDE DUAL-AUTHENTICATION (PIV & PIN) CARD READER ON VEHICLE
PEDESTAL FOR GATE OPERATION.
6 PROVIDE DUAL-AUTHENTICATION (PIV & PIN) WALL MOUNTED CARD
READER.
7 PROVIDE DUAL-AUTHENTICATION (PIV & PIN) CARD READER SURFACE
MOUNTED ON FENCE.
8 PROVIDE ONE (1) 2" CONDUIT WITH INNERDUCT IN CONCRETE ENCASED
DUCTBANK WITH 1-STRAND SINGLE MODE FIBER FOR CAMERA.
9 PROVIDE TWO (2) 2" CONDUITS WITH INNERDUCT IN CONCRETE ENCASED
DUCTBANK. ONE (1) CONDUIT WITH 2-STRAND SINGLE MODE FIBER FOR
CAMERA AND ONE (1) 2" CONDUIT WITH MULTI-CONDUCTOR CABLE FOR
PACS HARDWARE.
10 PROVIDE ONE (1) 2" CONDUIT WITH INNERDUCT IN CONCRETE ENCASED
DUCTBANK WITH MULTI-CONDUCTOR CABLE FOR PACS HARDWARE.
11 PROVIDE ONE (1) 2" CONDUIT WITH INNERDUCT IN CONCRETE ENCASED
DUCTBANK WITH CATEGORY-6A CABLING DEDICATED FOR SPS TRAILER
TELECOMMUNCIATIONS CONNECTIVITY.
12 STUB CONDUIT UP TO ABOVE DOOR TO CONNECT TO PACS HARDWARE.
13 PROVIDE VEHICLE DETECTION LOOP. COORDINATE CONNECTION INTO
GATE OPERATING SYSTEM CONTROLS. PROVIDE 3/4" CONDUIT FROM
TELECOMMUNICATIONS HANDHOLE FOR SENSE CABLING.
14 UTILIZE EXISTING HEAD-END EQUIPMENT LOCATED WITHIN EXISTING
TELECOMMUNICATIONS ROOM "IT-103" ON THE FIRST FLOOR OF BUILDING
77.
N
1/8" = 1'-0"
ESS TEMPORARY SPS TRAILER ENLARGED PLAN1
TELECOMMUNICATIONS KEYNOTES
CAMERA PER
SCHEDULE.
CORNER MOUNT ADAPTER AND BOTTOM
ENTRY ARM FOR CAMERA. SECURELY
FASTEN CORNER MOUNT ADAPTER TO
BUILDING STRUCTURE.
MINIMUM 3/4" LIQUID-TIGHT FLEXIBLE METAL
CONDUIT TO JUNCTION BOX WITH STAINLESS
STEEL COVER, SECURITY SCREWS, AND GASKET.
MINIMIZE CONDUIT LENGTH AND LOCATE JUNCTION
BOX ON SIDE OR REAR OF BUILDING.
EXTERIOR WALL CORNER.
1" CONDUIT TO SYSTEM HEAD-END. CABLING
PER RISER DIAGRAM.
MOUNTING HEIGHT
PER SCHEDULE OR
AS NOTED ON
DRAWINGS.
MOUNTING HEIGHT
PER SCHEDULE OR AS
NOTED ON DRAWINGS
CABLING PER RISER
DIAGRAM
EXPANSION ANCHORS
WITH STAINLESS STEEL
SECURITY FASTENERS
FLUSH MOUNTED OUTLET
BOX. COORDINATE
LOCATION TO MATCH
CAMERA WIRING LOCATION
ACCESS.
1" CONDUIT TO
NEAREST CABLE TRAY
WALL
CAMERA PER
SCHEDULE
MOUNTING HEIGHT
PER SCHEDULE OR AS
NOTED ON DRAWINGS.
LIGHT POLE SHAFT.
CABLING PER RISER
DIAGRAM.
POLE ADAPTER PLATE
AND ARM FOR CAMERA.
CAMERA POLE ADAPTER
MOUNTING STRAPS.
MINIMUM 3/4" LIQUID-TIGHT
FLEXIBLE METAL CONDUIT
WITH STRAIN RELIEF IN
POLE.
CAMERA PER
SCHEDULE.
HANDHOLE REQUIREMENTS
1. HOUSING SHALL BE POLYMER CONCRETE REINFORCED WITH A HEAVY WEAVE FIBERGLASS-REINFORCED POLYMER
WITH COMPRESSIVE STRENGTH OF NO LESS THAN 10,000 PSI.
2. COVER AND BOX SHALL WITHSTAND A SERVICE LOAD OF NO LESS THAN 22,500 LBS OVER A 10" x 10" AREA.
3. STRAIGHT-WALL OPEN BOTTOM CONSTRUCTION. CONDUITS SHALL ENTER FROM BOTTOM AND NOT SIDES OF
HANDHOLE.
4. PROVIDE STAINLESS STEEL BOLTS AND INSERTS.
5. PROVIDE WITH (2) 2 1/2" MOUSEHOLES.
6. PROVIDE LABEL "ELECTRICAL" FOR POWER HANDHOLES OR "TELECOMMUNICATIONS" FOR TELECOMMUNICATIONS
HANDHOLES, OR AS INDICATED.
22 24" X 36" X 24" DEEP
CONCRETE
RING AROUND BOX
BOX
AND
COVER
COMPACTED
EARTH
SECTIONAL BOX
WHEN REQUIRED
SKID
RESISTANT
SURFACE
STAINLESS
STEEL HEX
BOLT AND
WASHER
LABEL
PULL SLOT
CRUSHED ROCK
TYPE HANDHOLE SIZING
10"
6"
6"
6"
BELOW BOX
22 13" X 24" X 24" DEEP
22 24" X 24" X 24" DEEP
SIDE VIEW FRONT VIEW
WEATHER PROOF,
VANDAL RESISTANT
TALKBACK PUSH
BUTTON, BASIS OF
DESIGN IS VALCOM SIP
WITH INTERCOM
SYSTEM. RELATED
CABLING SHALL
ORIGINATE FROM
SECURITY EQUIPMENT
ROOM.
WEATHER GUARD HOOD.
KEYPAD/CARD READER
INTERFACED WITH ACCESS
CONTROL SYSTEM, GATE
CONTROLLER AND STOP/GO
LIGHT SYSTEM. SECURITY
SIGNAL CABLING SHALL
ORIGINATE FROM SECURITY
EQUIPMENT ROOM. REFER
TO CIVIL DRAWING FOR GATE
CONTROLLER
SPECIFICATION.
MOUNTED CAMERA
MOUNTED WITHIN 18'-0" FROM BASE OF POLE
TELECOM
MANUFACTURER PROVIDED ACCESS FOR TELECOM CABLING COVER
LFMC CONDUIT FOR TELECOM CABLING SEPARATION
GROUNDING LUG (CONNECT GROUNDS TO BUSHINGS AND POLE)
HANDHOLE
6" WITH GRAVEL FILL
ANCHOR BOLTS AND BASE PER MANUFACTURER
#4 BARE COPPER
1/3 HEIGHT OF POLE
UNLESS NOTED
OTHERWISE
CONNECTION TO BE EXOTHERMIC WELD WELDED
GROUND ROD 3/4"x10' COPPER CLAD STEEL
CAMERA/TELECOM
CONCRETE BASE
NOTES:
1. REFER TO SITE PLANS FOR POLE LOCATION AND CAMERA ORIENTATION.
INTERFACE BOX, FOR MORE
INFORMATION REFER TO SHEET
TY500, DETAIL 1. FIELD VERIFY
MOUNTING LOCATION AT JOB SITE.
1" LMFC, CAT 6 CABLING TO
POLE MOUNTED CAMERA(S)
16" x 16" x 8" SURFACE
MOUNTED NEMA 4X
ENCLOSURE WITH
BACKPANEL AND HINGED
KEYLOCKED DOOR.
CAT-6A CABLING
SURGE
SUPPRESSION
CAT-6A CABLING
PS
SMFO TO
ETHERNET MEDIA
CONVERTER
FIBER FURCATION
FAN-OUT KIT
ENCLOSURE
24VAC LV POWER CABLING
#10 GROUNDING CONDUCTOR
GROUND BAR
2 #12 AWG, 1 #12 GND
TO NEAREST AVAILABLE SPARE
CIRCUIT, REFER TO ELECTRICAL
24VAC LV POWER CABLING
120V DEVICE POWER SUPPLY
HIGH POE
INJECTOR
1"C, 6 STRAND
SMFO TO SOURCE #8 GROUNDING
CONDUCTOR TO
GROUND ROD
DRIVEN TO
EARTH
1"C 1"C
FINISH FLOOR
FINISH CEILING
J-BOX
A F
F
DETAIL NOTES:
1. ELEVATION VIEW FROM SECURED SIDE OF DOOR.
2. DETAIL IS DIAGRAMMATIC IN NATURE AND NOT TO BE
CONSTRUED AS ALL INCLUSIVE. COORDINATE WITH
ARCHITECTURAL DOOR HARDWARE, PLANS, AND DETAILS
FOR LOCATION OF DEVICES.
3. PROVIDE 18" SERVICE LOOP WITHIN EACH ROUGH-IN BOX.
LABEL/INSTALL ALL CABLES.
4. PROVIDE ROUGH-IN BOXES AND CONDUIT. PROVIDE PULL-
STRING IN ALL ROUGH-IN CONDUIT; PULL-STRING IN
FRAMES SHALL BE PROVIDED WITH WEIGHTED ENDS.
J-BOX
DETAIL NOTES:
1. ELEVATION VIEW FROM SECURED SIDE OF DOOR.
2. DETAIL IS DIAGRAMMATIC IN NATURE AND NOT TO BE
CONSTRUED AS ALL INCLUSIVE. COORDINATE WITH
ARCHITECTURAL DOOR HARDWARE, PLANS, AND DETAILS
FOR LOCATION OF DEVICES.
3. PROVIDE 18" SERVICE LOOP WITHIN EACH ROUGH-IN BOX.
LABEL/INSTALL ALL CABLES.
4. PROVIDE ROUGH-IN BOXES AND CONDUIT. PROVIDE PULL-
STRING IN ALL ROUGH-IN CONDUIT; PULL-STRING IN
FRAMES SHALL BE PROVIDED WITH WEIGHTED ENDS.
FINISH FLOOR
FINISH CEILING
A F
F
A. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE
CONSTRUED AS ALL INCLUSIVE; REFER TO PERTINENT SPECIFICATION
SECTIONS, FIELD VERIFY EXISTING CONDITIONS AND ADJUST WORK AS
REQUIRED TO EXECUTE SPECIFIED WORK.
B. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD
NOTES AND HISTORICAL DATA AND DOCUMENTATION AND ARE FOR
REFERENCE PURPOSES ONLY TO DEFINE SCOPE OF WORK; FIELD
VERIFY ALL CONDITIONS.
C. ELECTRICAL OUTLET/ DEVICES INDICATED ARE FOR COORDINATION &
REFERENCE PURPOSES; REFER TO ELECTRICAL, E-SERIES DRAWINGS
FOR ELECTRICAL WORK REQUIREMENTS AND SPECIFICATIONS.
D. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS SHALL
NOT BE SHUTDOWN WITHOUT WRITTEN AUTHORIZATION; ALL
REQUESTS SHALL BE SUBMITTED IN WRITING A MINIMUM OF TEN (10)
WORKING-DAYS PRIOR TO PROPOSED ACTIVITY DATE OR NEED
UNLESS DIRECTED OTHERWISE.
E. SEE T-000 ABBREVIATIONS, SYMBOLS, LEGENDS & NOTES FOR
SYMBOLS DEFINITION:
1. SYMBOLS GRAYED/ HALFTONE: INDICATED FOR REFERENCE AND/OR
INDICATING EXISTING UNLESS SPECIFICALLY NOTED OTHERWISE.
2. SYMBOLS DASHED OR SPECIFICALLY KEYED NOTED: INDICATES
DEMOLITION WORK.
F. SECURITY CONTRACTOR SHALL PROVIDE ALL POWER REQUIREMENTS
ASSOCIATED WITH ELECTRONIC SECURITY SYSTEMS.
G. COORDINATE TELECOMMUNICATIONS WORK WITH ALL OTHER
TRADES. VERIFY ALL EXISTING CONDITIONS BEFORE THE START OF
WORK.
H. COORDINATE WORK AND PHASING SCHEDULE WITH THE
CONTRACTING OFFICER'S REPRESENTATIVE.
I. GENERAL CONTRACTOR SHALL PROVIDE HANDHOLES EVERY 400 FEET
MINIMUM.
J. FOR DUCTBANK INFORMATION REFER TO SHEET TY500, DETAIL 12.
TELECOMMUNICATIONS GENERAL NOTES
HORIZONTAL
SLEEVE THROUGH
WALL
FIRE RATED PATHWAY
ICT CABLES
PROVIDE BEND-RADIUS PROTECTION; EACH SIDE
TYPICAL WALL ASSEMBLY; SEE ARCHITECTURAL
PLANS FOR CONSTRUCTION AND RATINGS; FIELD
VERIFY EXISTING CONDITIONS
VERTICAL SLEEVE
THROUGH FLOOR
FIRE/SMOKE-RATED SLEEVE
FINISH FLOOR
FIRESTOP GANGPLATE AND GANGPLATE CAP
MAINTAIN A MINIMUM 3/4" CLEARANCE AROUND CORE DRILL
OPENING.
PROVIDE A 4" CORE DRILL AT EACH RISER
LOCATION REQUIRED OR INDICATED.
ICT SYSTEM SLEEVE - DETAIL NOTES:
1. QUANTITIES SHALL BE AS DESIGNATED ON FLOOR PLANS AND ENLARGED PLANS.
2. PROVIDE MULTI-SLEEVE GANG KITS WHERE MORE THAN ONE SLEEVE IS SPECIFIED.
3. PROVIDE KICK-IN FLOOR PLATE KIT FOR 4" CORE DRILLED FLOOR
APPLICATIONS. INSTALL IN STRICT ACCORDANCE WITH MANUFACTURERS
INSTALLATION INSTRUCTIONS/RECOMMENDATIONS.
4. COMPLETE AND APPLY ALL FIRE-RATED LABELING PROVIDED WITH SLEEVES.
FINISH FLOOR
A F
F
DETAIL NOTES:
1. ELEVATION VIEW FROM SECURED SIDE OF DOOR.
2. DETAIL IS DIAGRAMMATIC IN NATURE AND NOT TO BE
CONSTRUED AS ALL INCLUSIVE. COORDINATE WITH
ARCHITECTURAL DOOR HARDWARE, PLANS, AND DETAILS
FOR LOCATION OF DEVICES.
3. PROVIDE 18" SERVICE LOOP WITHIN EACH ROUGH-IN BOX.
LABEL/INSTALL ALL CABLES.
4. PROVIDE ROUGH-IN BOXES AND CONDUIT. PROVIDE PULL-
STRING IN ALL ROUGH-IN CONDUIT; PULL-STRING IN
FRAMES SHALL BE PROVIDED WITH WEIGHTED ENDS.
J-BOX
6 2
TIE WIRE
INNERDUCT, SEE NOTE 5
DUCT BANK NOTES:
1. CONCRETE SHALL BE 3000 P.S.I. @ 28 DAYS, OR AS SPECIFIED.
2. PROVIDE REINFORCING RODS ON TOP AND BOTTOM OF DUCTS WHEN CROSSING
OR PLACED UNDER ROADWAYS OR PARKING AREAS.
3. MINIMUM COVER TO TOP OF ENVELOPE SHALL BE 36" [610MM].
4. PROVIDE MINIMUM 12" [152mm] SPACE BETWEEN POWER AND
TELECOMMUNICATION DUCTS. INCREASE SIZE AS REQUIRED.
5. INNERDUCT QUANTITY AND SIZE AS INDICATED ON PLANS.
6. PROVIDE MAGNETICALLY-DETECTABLE WARNING-TAPE.
7. INSTALL A MINIMUM OF (3) SPACERS PER 10 LINER FEET OF CONDUIT.
2-WAY DUCT LINE
MAGNETIC
WARNING
TAPE
RED DYE ADDED
TO TOP OF
CONCRETE
PLASTIC SPACER
RESTORE SURFACE
DUCT [SIZE AS INDICATED ON DWGS.]
6-WAY DUCT LINE 4-WAY DUCT LINE
BACKFILL
[76mm]
3" UNO
[152mm]
6" UNO (NOTE #4)
[76mm]
3" UNO
[76mm]
3" UNO
[7 m m
U N
O
[7 m m
U O
N
[7 m m
U
[76mm]
3" UON
[76mm]
3" UON
[76mm]
3" UON
[7 m m
U
[7 m m
U N
O
[7 m m
U N
O
[76mm]
3" UNO
[76mm]
3" UNO
[7 m m
U N
O [7 m m
U N
O[76mm]
3" UNO
36" MIN
M
IN
DUCT LINE TYPICAL
AS REQ'D
A S
R E
Q 'D th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR SBBL COLLABORATIVE JN, INC.
100 N. STONE AVE STE 1102
TUCSON, AZ 85701-1524
(520) 620-0255
NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023
NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024
NM ELEC - EVANS SORDIASHIE #22817 EXP. 12/31/2023
CIVIL / STRUCTURAL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
2519 MADISON AVE
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
HEALTHCARE PLANNER
THE INNOVA GROUP
3196 NORTH SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #: 1993.10
/9
/2
:1
:3
A
M
ESS DETAILS
JPH Drawing # 74 OF 75KGH
BID DOCUMENTS
REPAIR SPS SEWER AND
UPGRADE EQUIPMENT AREA
08/11/2023
501-21-101
RAYMOND G. MURPHY VAMC
1501 SAN PEDRO DRIVE SE
ALBUQUERQUE, NM 87108
TY500
N/A
NTS
EXTERIOR WALL MOUNT SECURITY CAMERA3NTS
EXTERIOR POLE-MOUNTED SINGLE CAMERA DETAIL4 NTS
EXTERIOR WALL CORNER MOUNT CAMERA DETAIL2
NTS
HANDHOLE (TRAFFIC)7
NTS
PERIMETER SECURITY ACCESS CONTROL PEDESTAL5NTS
CAMERA POLE BASE DETAIL6
NTS
INTERFACE BOX DETAIL1
NTS
SECURITY DOOR HARDWARE ELEVATION HW-CM7159NTS
SECURITY DOOR HARDWARE ELEVATION HW-ACM71410
1 PROVIDE NEW DUAL-AUTHENTICATION CARD READER WITH KEYPAD
COMBINATION DEVICE. CONNECT NEW DUAL-AUTHENTICATION CARD
READER WITH KEYPAD TO NEW CIRCUIT AND PATHWAY. CARD READER
MOUNTED ON NON-SECURED SIDE OF DOOR.
2 PROVIDE MAGNETIC LOCK. FIELD VERIFY MOUNTING AND CABLING
REQUIREMENTS.
3 PROVIDE MINIMUM 1-1/4" CONDUIT. FIELD VERIFY ROUTING AT JOB SITE.
4 PROVIDE INTEGRATED DOOR CONTACT WITH ANTI-PROP/FORCED ENTRY
ALARM. FIELD VERIFY MOUNTING AND CABLING REQUIREMENTS.
5 TO C/C PACS HEAD-END EQUIPMENT ENCLOSURE, DOOR CONTROLLERS
AND POWER SUPPLIES. REFER TO ELECTRICAL FOR DEDICATED 120V
POWER.
6 PROVIDE MULTI-CONDUCTOR CABLE(S). COORDINATE REQUIREMENTS WITH
MANUFACTURERS' RECOMMENDATIONS.
7 PROVIDE NEW REQUEST TO EXIT PUSH BUTTON DEVICE. FIELD VERIFY
EXACT MOUNTING LOCATION AT JOB SITE.
TELECOMMUNICATIONS KEYNOTES#
NTS
FIRE PROOF WALL PENETRATION DETAIL8
NTS
SECURITY GATE HARDWARE ELEVATION11NTS
ESS AND ICT DUCT BANK DETAILS12
A. DRAWING IS DIAGRAMMATIC IN NATURE AND IS NOT TO BE
CONSTRUED AS ALL INCLUSIVE; REFER TO PERTINENT SPECIFICATION
SECTIONS, FIELD VERIFY EXISTING CONDITIONS AND ADJUST WORK AS
REQUIRED TO EXECUTE SPECIFIED WORK.
B. EXISTING CONDITIONS INDICATED ARE BASED ON GENERAL FIELD
NOTES AND HISTORICAL DATA AND DOCUMENTATION AND ARE FOR
REFERENCE PURPOSES ONLY TO DEFINE SCOPE OF WORK; FIELD
VERIFY ALL CONDITIONS.
C. ELECTRICAL OUTLET/ DEVICES INDICATED ARE FOR COORDINATION &
REFERENCE PURPOSES; REFER TO ELECTRICAL, E-SERIES DRAWINGS
FOR ELECTRICAL WORK REQUIREMENTS AND SPECIFICATIONS.
D. THIS SITE IS AN ACTIVE WORKING ENVIRONMENT; SYSTEMS SHALL
NOT BE SHUTDOWN WITHOUT WRITTEN AUTHORIZATION; ALL
REQUESTS SHALL BE SUBMITTED IN WRITING A MINIMUM OF TEN (10)
WORKING-DAYS PRIOR TO PROPOSED ACTIVITY DATE OR NEED
UNLESS DIRECTED OTHERWISE.
E. SEE T-000 ABBREVIATIONS, SYMBOLS, LEGENDS & NOTES FOR
SYMBOLS DEFINITION:
1. SYMBOLS GRAYED/ HALFTONE: INDICATED FOR REFERENCE AND/OR
INDICATING EXISTING UNLESS SPECIFICALLY NOTED OTHERWISE.
2. SYMBOLS DASHED OR SPECIFICALLY KEYED NOTED: INDICATES
DEMOLITION WORK.
F. SECURITY CONTRACTOR SHALL PROVIDE ALL POWER REQUIREMENTS
ASSOCIATED WITH ELECTRONIC SECURITY SYSTEMS.
G. COORDINATE TELECOMMUNICATIONS WORK WITH ALL OTHER
TRADES. VERIFY ALL EXISTING CONDITIONS BEFORE THE START OF
WORK.
H. COORDINATE WORK AND PHASING SCHEDULE WITH THE
CONTRACTING OFFICER'S REPRESENTATIVE.
I. GENERAL CONTRACTOR SHALL PROVIDE HANDHOLES EVERY 400 FEET
MINIMUM.
J. FOR DUCTBANK INFORMATION REFER TO SHEET TY500, DETAIL 12.
TELECOMMUNICATIONS GENERAL NOTES
ACS-CP
ACS-CP
PS
PS
x5 x5
IT 103
x4 x2 x1 x3
103A 103B VEHICLE
GATE
ENTRANCE
PERIMETER
GATE NORTH
PERIMETER
GATE WEST
CR ML DM CR ML DMDM DM MLCR ML CRRE CR ML DM RE RE RE
FIRST FLOOR
IT 103
EXTERIOR
C-04
C-02
C-01
C-02
C-03
BUILDING 77 IT ROOM 103 SPS TRAILER WEST
LEVEL 1
NOTES:
1. DIAGRAM DOES NOT REFLECT ACTUAL PATHWAY CONDITIONS. REFER TO
TY401.
2. DIAGRAM DOES NOT REFLECT EXACT COMMUNICATION RACK LOCATIONS OR
QUANTITIES.
5 21
SPS TRAILER EAST
20 20 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
VA Health Care System Approval:
ARCHITECT:
SPUR SBBL COLLABORATIVE JN, INC.
100 N. STONE AVE STE 1102
TUCSON, AZ 85701-1524
(520) 620-0255
NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023
NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024
NM ELEC - EVANS SORDIASHIE #22817 EXP. 12/31/2023
CIVIL / STRUCTURAL ENGINEER
H2B, INC.
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
2519 MADISON AVE
KANSAS CITY, MO 64108
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
HEALTHCARE PLANNER
THE INNOVA GROUP
3196 NORTH SWAN ROAD
TUCSON, AZ 85712
(520) 886-8650
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #: 1993.10
/9
/2
:1
:3
A
M
ESS RISERS AND DIAGRAMS
JPH Drawing # 75 OF 75KGH
BID DOCUMENTS
REPAIR SPS SEWER AND
UPGRADE EQUIPMENT AREA
08/11/2023
501-21-101
RAYMOND G. MURPHY VAMC
1501 SAN PEDRO DRIVE SE
ALBUQUERQUE, NM 87108
TY600
N/A
1 EXISTING ACS POWER SUPPLY. FIELD VERIFY SPARE CAPACITY AND
ADJUST WORK AS NECESSARY TO PROVIDE FULLY FUNCTIONAL SYSTEM.
2 EXISTING ACS CONTROL PANEL. FIELD VERIFY SPARE CAPACITY AND
ADJUST WORK AS NECESSARY TO PROVIDE FULLY FUNCTIONAL SYSTEM.
3 PROVIDE RS-232 22 AWG/4C.
4 PROVIDE MULTICONDUCTOR CABLE.
5 EXISTING TELECOMMUNICATIONS EQUIPMENT RACK/ CABINET.
6 EXISTING CATEGORY-6A CABLE.
7 PROVIDE ACS CONTROL PANEL. FIELD VERIFY SPARE CAPACITY AND
ADJUST WORK AS NECESSARY TO PROVIDE FULLY FUNCTIONAL SYSTEM.
8 PROVIDE ACS POWER SUPPLY. FIELD VERIFY SPARE CAPACITY AND
ADJUST WORK AS NECESSARY TO PROVIDE FULLY FUNCTIONAL SYSTEM.
9 120V POWER REFER TO ELECTRICAL.
10 PROVIDE CATEGORY-6A CABLING DEDICATED FOR ACS CONTROL PANEL.
11 PROVIDE FIBER OPTIC CABLING.
12 PROVIDE FIBER OPTIC TO CATEGORY-6A CONVERTER.
13 PROVIDE CATEGORY-6A CABLING.
14 PROVIDE LAN SWITCH.
15 PROVIDE VMS/ NVR.
16 INSTALL NEW HANDHOLE; SEE SHEET TY500 DETAIL 7.
17 PROVIDE SINGLE MODE OS2 FIBER-OPTIC CABLING AND PATHWAY.
18 VA FURNISHED AND INSTALLED NETWORK SWITCH, CONTRACTOR SHALL
COORDINATE INSTALLATION OF VA PROVIDED SWITCH WITH VA OI&T.
19 PROVIDE 12 PAIR OF COPPER CABLING FROM WEST SPS TRAILER TO EAST
SPS TRAILER.
20 PROVIDE SURGE SUPPRESSION DEVICES BEFORE ENTERING SWITCHES
FOR ALL EXTERIOR ROUTED COPPER CABLING.
21 NEW TELECOMMUNICATIONS EQUIPMENT RACK/ CABINET BY OTHERS.
TELECOMMUNICATIONS KEYNOTES#
NTS
SITE ESS RISER DIAGRAM1NTS
SITE SECURITY AND SURVEILLANCE TELEVISION RISER2
NTS
ESS OSP INFRASTRUCTURE RISER3
1. PROVIDE ALL ACCESSORIES AS REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM COMPATIBLE WITH THE EXISTING CAMPUS SSTV SYSTEM. PROVIDE ALL UPGRADES TO EXISTING VASS SYSTEM TO INCORPORATE NEW SURVEILLANCE CAMERAS.
NOTES:
SECURITY AND SURVEILLANCE TELEVISION (SSTV) CAMERA SCHEDULE
TYPE DESCRIPTION MOUNTING TYPE
MOUNTING
HEIGHT
LOCATION MODELS
IMAGER SIZE,
RESOLUTION
LENS TYPE POWER COLOR COMMENTS NOTES
C-01
90-Degree Camera, programmed with behavior analytics to detect fighting/ running, gunshot, facial recognition, and license plate scanning.
Wall 9'-0" Outdoor Compatible with VA campus head-end security surveillance system.
1 x 1/3" / 12MP (min)
Remote focus, Verifocal Lens
Power over ethernet
Black
C-02
360-Degree Camera, programmed with behavior analytics to detect fighting/ running, gunshot, facial recognition, and license plate scanning.
Light Pole 16'-0" Outdoor Compatible with VA campus head-end security surveillance system.
4 x 1/3" / 12MP (min)
Remote focus, Verifocal Lens
Power over ethernet
Black
C-03
270-Degree Camera, programmed with behavior analytics to detect fighting/ running, gunshot, facial recognition, and license plate scanning.
Parapet 16'-0" Outdoor Compatible with VA campus head-end security surveillance system.
3 x 1/3" / 12MP (min)
Remote focus, Verifocal Lens
Power over ethernet
Black
C-04
180-Degree Camera, programmed with behavior analytics to detect fighting/ running, gunshot, facial recognition, and license plate scanning.
Wall 9'-0" Outdoor Compatible with VA campus head-end security surveillance system.
2 x 1/3" / 12MP (min)
Remote focus, Verifocal Lens
Power over ethernet
Black