ATTACHMENT 1D - Drawings-Architectural.pdf

PDF 3 MB Posted

Attached to
Project# 501-21-101: Repair Sterile Processing Service (SPS) & Upgrade Equipment Area
Solicitation number
36C26224B0007
Issued by

About this file

This document package includes architectural drawings and specifications for renovations to the Sterile Processing Service department located in Building 41 at the Raymond G. Murphy VA Medical Center in Albuquerque, New Mexico. Key project details include renovating flooring, walls, casework, and plumbing fixtures in soiled receiving, sterilization preparation, equipment storage and other areas. Temporary buildings and covered walkways will be installed to facilitate continued operations during construction. Mechanical, electrical and technology systems will also be upgraded as specified in supplementary drawings and documents not provided. The pre-solicitation notice identifies Solicitation Number 36C26224B0007 for bids to repair sewer lines serving the area and perform the renovations, with an anticipated award date in late 2023.

View the file

Other files

File Type Posted
C01 Award Notice of 36C26224C0167.pdf PDF
S06 36C26224B0007 0006.pdf PDF
S06 ATTACHMENT 4 - REVISED WAGE DETERMINATION NM20240044 01-06-2024.pdf PDF
S06 36C26224B0007 0005.pdf PDF
AMENDMENT 0004 - ATTACHMENT A - GEOTECHNICAL REPORT.pdf PDF
AMENDMENT 0004 - ATTACHMENT C - ASBESTOS SURVEY REPORT.pdf PDF
AMENDMENT 0004 - ATTACHMENT B - SECTION 26 12 19.pdf PDF
AMENDMENT 0004 - ATTACHMENT 4 - REVISED WAGE DETERMINATION NM20240001.pdf PDF
S06 36C26224B0007 0004.pdf PDF
S06 36C26224B0007 0003.pdf PDF
S06 36C26224B0007 0002 01-30-2024.pdf PDF
S06 36C26224B0007 0001 01162024.pdf PDF
ATTACHMENT 4 - WAGE DETERMINATION NM20230044 06-09-2023.pdf PDF
ATTACHMENT 1H - Drawings-Electrical.pdf PDF
ATTACHMENT 1A - Drawings-General.pdf PDF
ATTACHMENT 1E - Drawings-Fire Protection.pdf PDF
ATTACHMENT 1F - Drawings-Plumbing.pdf PDF
ATTACHMENT 1C- Drawings-Structural.pdf PDF
ATTACHMENT 1B - Drawings-Civil.pdf PDF
ATTACHMENT 2 - 501-21-101 Bid Spec Complete-Updated.pdf PDF
ATTACHMENT 1G - Drawings-Mechanical.pdf PDF
ATTACHMENT 3 - RFI FORM 501-21-101.docx DOCX document
ATTACHMENT 1I - Drawings-Telecommunications.pdf PDF
S02 36C26224B0007.docx DOCX document
S02. 36C26224B0007 Pre-Solicitation Notice.docx DOCX document
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXISTING BUILDING FOOTPRINT (NOT IN SCOPE)

SITE PLAN LEGEND

SECURITY BOLLARD - REMOVABLE

EXISTING LIGHT POST

TEMPORARY VEHICLE CRASH BARRIER

EXISTING TREE TO REMAIN

CAMERA LOCATION; REFER TO TELECOM DRAWINGS FOR TYPE AND VIEWING

ANGLE

SPS TRAILER NO. 1

S P

S T

R A

IL

E

R N

O . 2

BUILDING

LO

O

P R

O A

D

MEDICAL GROUP DR.

BUILDING

US VETERANS

HOSPITAL LOOP

USAF PARKING

MEDICAL GROUP DR.

R 50'-0"

R 50'-0

'-0

R

0' -0

50'-8"

BUILDING

CR

28.01

CR

10.32

28.01

28.02

26.05

28.02

26.05

28.01

CR

28.02

8' -7

9'-4 1/2"

26.04

32.02

32.02

32.02

32.02

5 1/4" /

1'-0"

TYP.

1" / 1'-0" th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR SBBL COLLABORATIVE JN, INC.

100 N. STONE AVE STE 1102

TUCSON, AZ 85701-1524

(520) 620-0255

NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023

NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024

NM ELEC - EVANS SORDIASHIE #22917 EXP. 12/31/2023

CIVIL / STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

2519 MADISON AVE

KANSAS CITY, MO 64108

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

HEALTHCARE PLANNER

THE INNOVA GROUP

3196 NORTH SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:4

:2

A

M

SITE PLAN

NR 29 79AJS

BID DOCUMENTS

REPAIR SPS SEWER AND

UPGRADE EQUIPMENT AREA

08/11/2023

501-21-101

RAYMOND G. MURPHY VAMC

1501 SAN PEDRO DRIVE SE

ALBUQUERQUE, NM 87108

A-000

SPUR #: 1993.10

KEYNOTE LEGEND

10.32 SLIDING GATE, REFER TO CIVIL.

26.04 GENERATOR, SEE ELECTRICAL DRAWINGS

26.05 EXTERIOR LIGHT POLE, REFER TO ELECTRICAL.

28.01 DUAL-AUTHENTICATION (PIN & PIV) CARD READER, REFER TO TECHNOLOGY

28.02 CAMERA LOCATION, REFER TO TECHNOLOGY DRAWINGS FOR CAMERA TYPE AND VIEWING

ANGLE

32.02 SECURE TEMPORARY METAL FENCE

N

1" = 20'-0"

ARCHITECTURAL SITE PLAN - TEMPORARY BUILDINGS1

No. REVISION DESCRIPTION DATE

DN

16'-8 1/2"

19'-2"

BUILDING 45

BUILDING

SPS TRAILER NO. 1

S P

S T

R A

IL

E

R N

O . 2

A-001

EXISTING RAMP

67'-5"

8' -1

1/

2"

9'-4 1/2"

CORRIDOR

3B

103A

7.87 7.87

7.87

7.87

'-8

16'-0"

6'-8"

6' -8

C R

C R

CR CR

CR

28.01 28.01

28.01

28.01

11'-4 1/2"

A-001

AE300

26.04

A-001

A-001

A-001

A-001

6'-8" 8'-0"

14.08

AE401

ENTRY

5'-7"

C R28.01

CR28.01

32.02

A-001

1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT

WALL UNLESS NOTED OTHERWISE.

2. ALL WALLS ARE TYPE C3 PARTITIONS UNLESS OTHERWISE NOTED.

REFER TO PARTITION TYPE SHEET FOR WALL TYPES.

3. ALL INFILLING WALLS TO MATCH THE THICKNESS OF THE INFILLING WALL UNLESS NOTED

OTHERWISE.

4. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE300) FOR DOOR INFORMATION.

5. REFER TO GLAZING ELEVATIONS & DETAILS SHEET (AE300) FOR WINDOW INFORMATION.

6. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.

7. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW TOLERANCE

FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.

8. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.

9. CONTRACTOR TO REMOVE AND RETAIN ALL SIGNAGE FOR REINSTALLATION AFTER CONSTRUCTION.

COORDINATE WITH VA.

10. REFER TO SHEET AE102 FOR EQUIPMENT SCHEDULE.

GENERAL PLAN NOTES

B45 FINSH FLOOR

0"

SPS TRAILERS AND

TEMPORARY BUILDINGS -

3'-6"

A-001

A-001

CORRIDOR

SPS

TRAILER

NO. 2

B45 FINSH FLOOR

0"

SPS TRAILERS AND

TEMPORARY BUILDINGS -

3'-6"

A-001

10.30

7.10

6.02

7.03

9.13

9.85

6.58

9.13

7.12

7.33

7.190

7.200

CORRIDOR

9.970

9.299.40

5 1/4" / 1'-0"

6.59

R-30 R-30

R-30

R-20 R-20

7' -1

1" 3'

-6

A-001

A-001

CORRIDOR

BUILDING 45

SPS TRAILER NO. 1

S P

S T

R A

IL

E

R N

O . 2

A-001

2.14 2.14

A-001

U0007

U0006

B45 FINSH FLOOR

0"

SPS TRAILERS AND

TEMPORARY BUILDINGS -

3'-6"

CORRIDOR

TEMP SPS

TRAILER

7.87

7.87

3.01

B45 FINSH FLOOR

0"

SPS TRAILERS AND

TEMPORARY BUILDINGS -

3'-6"

10.31

A-001

5.29

B45 FINSH FLOOR

0"

SPS TRAILERS AND

TEMPORARY BUILDINGS -

3'-6"

10.31

M

IN

IM

U

M

'-0

5.29

A-001

A-001

7.190

7.210

ENCLOSED

CORRIDOR

DROP-OFF

CANOPY

1" / 1'-0"

B45 FINSH FLOOR

0"

10.31

5.29

7"

3.01

REFLECTED CEILING PLAN LEGEND

GYPSUM BOARD CEILING OR

SOFFIT

4' LED STRIP LIGHT

EXIT LIGHT OR SIGN

4' LED STRIP LIGHT

(EMERGENCY POWER)

B45 FINSH FLOOR

0"

SPS TRAILERS AND

TEMPORARY BUILDINGS -

3'-6"

A-001

10.31

5.29

26.01

A-001

B45 FINSH FLOOR

0"

SPS TRAILERS AND

TEMPORARY BUILDINGS -

3'-6"

9.13

9.970

5.30

9.40

6.60

6.61

5.18

ENTRY

B45 FINSH FLOOR

0"

SPS TRAILERS AND

TEMPORARY BUILDINGS -

3'-6"

7.210 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR SBBL COLLABORATIVE JN, INC.

100 N. STONE AVE STE 1102

TUCSON, AZ 85701-1524

(520) 620-0255

NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023

NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024

NM ELEC - EVANS SORDIASHIE #22917 EXP. 12/31/2023

CIVIL / STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

2519 MADISON AVE

KANSAS CITY, MO 64108

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

HEALTHCARE PLANNER

THE INNOVA GROUP

3196 NORTH SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:4

:2

A

M

TEMPORARY STRUCTURES

NR 30 79AJS

BID DOCUMENTS

REPAIR SPS SEWER AND

UPGRADE EQUIPMENT AREA

08/11/2023

501-21-101

RAYMOND G. MURPHY VAMC

1501 SAN PEDRO DRIVE SE

ALBUQUERQUE, NM 87108

A-001

SPUR #: 1993.10

N

1/8" = 1'-0"

SPS TRAILERS AND TEMPORARY BUILDINGS - REFERENCE PLAN4

KEYNOTE LEGEND

2.14 EXISTING METAL LOUVERS TO BE REPLACED WITH 90 MINUTE FIRE RATED LOUVER.

CONTRACTOR TO FEILD MEASURE AND PROVIDE SAME SIZES.

3.01 CONCRETE FOOTING. SEE STRUCT. DWG'S

5.18 METAL RAILING

5.29 METAL PANEL MECHANICALLY FASTENED TO METAL FRAMING

5.30 EDGE TRIM

6.02 1/2" PLYWOOD SHEATHING

6.58 2x8 WOOD BLOCKING

6.59 2x8 WOOD STUDS

6.60 2x12 WOOD BLOCKING

6.61 2x4 WOOD STUDS

7.03 BATT INSULATION

7.10 VAPOR BARRIER

7.12 SHEET METAL FLASHING

7.33 ASPHALT SHINGLES

7.87 FLEXIBLE EXPANSION JOINT. 1" PRE-COMPRESSED FIRE RETARDANT FOAM WITH WATERPROOF

SILICON ON EACH SIDE.

7.190 ALUMINUM DOWNSPOUT

7.200 SPLASH BLOCK

7.210 ALUMINUM GUTTER

9.13 5/8" GYPSUM WALL BOARD

9.29 BASE AS SCHEDULED

9.40 FLOORING AS SCHEDULED. REFER TO FINSH SCHEDULE ON SHEET AF701.

9.85 FIBER REINFORCED PLASTIC

9.970 1 1/2 LIGHTWEIGHT CONCRETE

10.30 VINYL SIDING

10.31 PREFABRICATED STEEL CANOPY WITH A MIN CLEARANCE DIMENSION OF 18'-0". FOOTINGS AND

FOUNDATION BY GENERAL CONTRACTOR, REFER TO STRUCTURAL DRAWINGS.

14.08 WHEELCHAIR LIFT

26.01 LIGHT FIXTURE, SEE SCHEDULE

26.04 GENERATOR, SEE ELECTRICAL DRAWINGS

28.01 DUAL-AUTHENTICATION (PIN & PIV) CARD READER, REFER TO TECHNOLOGY

32.02 SECURE TEMPORARY METAL FENCE

1/8" = 1'-0"

NORTH/SOUTH SECTION5

1/2" = 1'-0" 4/ A-001

SPS TRAILER SECTION2

N

1/8" = 1'-0"

TEMPORARY COVERED WALKWAY - RCP8

No. REVISION DESCRIPTION DATE

1/2" = 1'-0"

SECTION AT TRAILER CONNECTION1

1/8" = 1'-0" 4/ A-001

WEST ELEVATION7 1/8" = 1'-0" 4/ A-001

NORTH/SOUTH SECTION6

1 1/2" = 1'-0" 6/ A-001

SECTION DETAIL11 1/8" = 1'-0" 4/ A-001

EAST/WEST SECTION10

1/2" = 1'-0" 4/ A-001

SECTION DETAIL3

3/8" = 1'-0"

NORTH/SOUTH SECTION9

FLDR

FLDR

DN

UP

DN.

UP

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT

WALL UNLESS NOTED OTHERWISE.

2. ALL WALLS ARE TYPE C3 PARTITIONS UNLESS OTHERWISE NOTED.

REFER TO PARTITION TYPE SHEET FOR WALL TYPES.

3. ALL INFILLING WALLS TO MATCH THE THICKNESS OF THE INFILLING WALL UNLESS NOTED

OTHERWISE.

4. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE300) FOR DOOR INFORMATION.

5. REFER TO GLAZING ELEVATIONS & DETAILS SHEET (AE300) FOR WINDOW INFORMATION.

6. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.

7. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW TOLERANCE

FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.

8. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.

9. CONTRACTOR TO REMOVE AND RETAIN ALL SIGNAGE FOR REINSTALLATION AFTER CONSTRUCTION.

COORDINATE WITH VA.

10. REFER TO SHEET AE102 FOR EQUIPMENT SCHEDULE.

GENERAL PLAN NOTES

1 2 3 4 5 6 7 8 9 10

44'-6" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 28'-0" 28'-0" 22'-6" 22'-6" 22'-6" 22'-6" 22'-6" 44'-6"

11 12 13 14 15

A

B

C

G

H

I

'-0

'-0

'-0

'-0

'-0

0'

-0

370'-0"

OFFICE OF

CHIEF

BIOMED

BC-125A

RECEPTION

AND PGM

ASST. BC-125

CORRIDOR

CB-25 1-A4

MECH BD-141

ELECTRICAL

CLOSET

BC-110E

SIGNAL

CLOSET

BC-110D

CLOSET

BC-110C

HALL

BC-110B

PARTS RM.

BC-126A

TECHNICAL

WORK SPACE

BC-126

MECH RM

SOILED RECV &

DECONTAMINATION

STERILIZATION

PREPARATION

EQUIP TEST & STORAGE WORK AREA & STOR

BIOMED WORK SPACE

OFFICE

BREAKDOWN

HALL

BREAK ROOM

STAFF WORK AREA

CORRIDOR

CART WASH

C O

R R

ID

O

R

SPS CHANGE AREA

HLD DECON

CORRIDOR

CORRIDOR

C O

R R

ID

O

R C

O R

R

ID

O R

RECEPTION

LOCKERS

OFFICE

HACTLT

TLT

TLT

TLT (F)

STOR

MECH

MED SUPPLY TECH

AREA IN SCOPE

REFERENCE PLAN LEGEND

AREA NOT IN SCOPE

SPS DEPARTMENT

BUILDING 41

BASEMENT LEVEL, QUAD C

N th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR SBBL COLLABORATIVE JN, INC.

100 N. STONE AVE STE 1102

TUCSON, AZ 85701-1524

(520) 620-0255

NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023

NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024

NM ELEC - EVANS SORDIASHIE #22917 EXP. 12/31/2023

CIVIL / STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

2519 MADISON AVE

KANSAS CITY, MO 64108

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

HEALTHCARE PLANNER

THE INNOVA GROUP

3196 NORTH SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:4

:2

A

M

SPS - OVERALL PLAN - B41 BASEMENT

NR 31 79AJS

BID DOCUMENTS

REPAIR SPS SEWER AND

UPGRADE EQUIPMENT AREA

08/11/2023

501-21-101

RAYMOND G. MURPHY VAMC

1501 SAN PEDRO DRIVE SE

ALBUQUERQUE, NM 87108

A-002

SPUR #: 1993.10

N

1/16" = 1'-0"

BLDG 41 - BASEMENT FLOOR PLAN1

RAYMOND G. MURPHY VA MEDICAL CENTER CAMPUS

BASE

PLAN

HEAD

METAL STUD U-TRACK (TOP AND BOTTOM)

LINE OF CEILING

(REF: RCP FOR HEIGHT & TYPE)

WALL FINISH

(REF: ROOM FINISH SCHEDULE)

WIDTH

ACTUAL

5/8"

WIDTH

STUD 5/8"

BASE

PLAN

HEAD

LINE OF CEILING

(REF: RCP FOR HEIGHT & TYPE)

WALL FINISH

(REF: ROOM FINISH SCHEDULE)

5/8" GYPSUM BOARD EACH SIDE

FIN FLOOR (REF: ROOM FINISH SCHEDULE)

BASE - (REF: ROOM FINISH SCHEDULE)

FIN FLOOR (REF: ROOM FINISH SCHEDULE)

BASE (REF: ROOM FINISH SCHEDULE)

BATT INSULATION WHERE

SPECIFIED IN SCHEDULE

BASE

PLAN

HEAD

UNDERSIDE OF STRUCTURE

METAL RUNNER (FASTENED 24" O.C. MAX)

WALL FINISH (REF: ROOM FINISH SCHEDULE)

WIDTH

ACTUAL

5/8"TYPE X

5/8"TYPE X

2 LAYERS "TYPE X" GYPSUM BOARD

METAL RUNNER "J"

(FASTENED 24" O.C. MAX)

FIN FLOOR (REF: ROOM FINISH SCHEDULE)

BASE (REF: ROOM FINISH SCHEDULE)

CH STUD PER SCHEDULE

ROOM SIDE SHAFT SIDE

1" TYPE X GYPSUM BOARD LINER PANEL

BASE

PLAN

HEAD

UNDERSIDE OF STRUCTURE

LINE OF CEILING

(REF: RCP FOR HEIGHT & TYPE)

WALL FINISH

(REF: ROOM FINISH SCHEDULE)

WIDTH

ACTUAL

5/8"TYPE X

WIDTH

STUD 5/8"TYPE X

5/8" "TYPE X" GYPSUM

BOARD EACH SIDE

FINISH FLOOR

(REF: ROOM FINISH SCHEDULE)

BASE (REF: ROOM FINISH SCHEDULE)

METAL STUD PER SCHEDULE

BASE

PLAN

HEAD

UNDERSIDE OF STRUCTURE

WALL FINISH

(REF: ROOM FINISH SCHEDULE)

WIDTH

ACTUAL

1"TYPE X

FIN FLOOR- (REF: ROOM FINISH SCHEDULE)

BASE - (REF: ROOM FINISH SCHEDULE)

ROOM SIDE SHAFT SIDE

BASE

PLAN

HEAD

UNDERSIDE OF STRUCTURE

LINE OF CEILING

(REF: RCP FOR HEIGHT & TYPE)

WALL FINISH

(REF: ROOM FINISH SCHEDULE)

ACTUAL

5/8"TYPE X

5/8"TYPE X

WIDTH

STUD

5/8"TYPE X

5/8"TYPE X

2 LAYERS "TYPE X" GYPSUM

BOARD EACH SIDE

FINISH FLOOR

(REF: ROOM FINISH SCHEDULE)

BASE (REF: ROOM FINISH SCHEDULE)

BATT INSULATION

BASE

PLAN

HEAD

UNDERSIDE OF STRUCTURE

LINE OF CEILING (REF: RCP FOR HEIGHT & TYPE)

WALL FINISH (REF: ROOM FINISH SCHEDULE)

WIDTH

ACTUAL

5/8"

WIDTH

STUD VARIES

WIDTH

STUD 5/8"

5/8" GYPSUM BOARD EACH SIDE

FIN FLOOR (REF: ROOM FINISH SCHEDULE)

BASE - (REF: ROOM FINISH SCHEDULE)

METAL STUD PER SCHEDULE

BATT INSULATION WHERE SPECIFIED

IN SCHEDULE

METAL STUD PER SCHEDULE

FIRE RATED SEALANT AROUND PERIMETER

FIRE RATED SEALANT AROUND PERIMETER

FIRE RATED SEALANT AROUND PERIMETER

FIRE RATED SEALANT AROUND PERIMETER

BATT INSULATION

FIRE RATED SEALANT

AROUND PERIMETER

FIRE RATED SEALANT AROUND PERIMETER

FIRE RATED SEALANT AROUND PERIMETER

ACOUSTICAL SEALANT AROUND

PERIMETER (INSULATED WALLS)

ACOUSTICAL SEALANT AROUND

PERIMETER (INSULATED WALLS)

NOTE: INSULATED WALLS AROUND

RESTROOMS EXTEND OUTSIDE LAYER

OF GYPSUM BOARD TO DECK

ACOUSTICAL SEALANT AROUND

PERIMETER (INSULATED WALLS)

WIDTH

STUD5/8"

WIDTH

ACTUAL

BATT INSULATION WHERE

SPECIFIED IN SCHEDULE

DIM DIMDIM DIMDIM DIM

DIM DIMDIM DIM

LINE OF CEILING

(REF: RCP FOR HEIGHT & TYPE)

DIM DIM DIM DIM

BASE

PLAN

HEAD

DIM DIM

WIDTH

ACTUAL

5/8"

WIDTH

STUD 5/8"

1"TYPE XWIDTH

STUD

5/8"TYPE X

WIDTH

STUD

CH STUD PER SCHEDULE

METAL STUD PER SCHEDULE METAL STUD PER SCHEDULE

5/8" GYPSUM WALLBOARD

METAL STUD U-TRACK (TOP AND BOTTOM)

METAL STUD U-TRACK (TOP AND BOTTOM)

METAL STUD U-TRACK (TOP AND BOTTOM)

1" GYPSUM SHAFT LINER

METAL STUD U-TRACK (TOP AND BOTTOM)

UNDERSIDE OF STRUCTURE

LINE OF CEILING (REF: RCP FOR HEIGHT & TYPE)

WALL FINISH (REF: ROOM FINISH SCHEDULE)

5/8" GYPSUM BOARD EACH SIDE

FIN FLOOR (REF: ROOM FINISH SCHEDULE)

BASE (REF: ROOM FINISH SCHEDULE)

METAL STUD PER SCHEDULE

FIRE-RATED SEALANT AROUND PERIMETER

METAL STUD U-TRACK (TOP AND BOTTOM)

A1 NON-INSULATED 5/8" GYPSUM BOARD ONE SIDE 7/8" HAT CHANNEL

SPACED AT 16" O.C.

1 1/2" --

TYPE MARK WALL TYPE DESCRIPTION WIDTH MIN. STC

A2 NON-INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 2 1/2" METAL

STUD AT 16" O.C.

3 1/8" --

A3 NON-INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 3 5/8" METAL

STUD AT 16" O.C.

4 1/4" --

A6 NON-INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 6" METAL STUD

AT 16" O.C.

6 5/8" --

B2 INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 2 1/2" METAL

STUD AT 16" O.C. W/ BATT INSULATION

3 1/8" --

B3 INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 3 5/8" METAL

STUD AT 16" O.C. W/ BATT INSULATION

4 1/4" --

B6 INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 6" METAL STUD

AT 16" O.C. W/ BATT INSULATION

6 5/8" --

C2 NON-INSULATED --

TYPE MARK WALL TYPE DESCRIPTION WIDTH MIN. STC

C3 NON-INSULATED

5/8" GYPSUM BOARD EACH SIDE OF 2 1/2" METAL

STUD AT 16" O.C.

3 3/4"

C6 NON-INSULATED

5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL

STUD AT 16" O.C.

4 7/8"

D2

5/8" GYPSUM BOARD EACH SIDE OF 6" METAL STUD

AT 16" O.C.

7 1/4"

D3 INSULATED

5/8" GYPSUM BOARD EACH SIDE OF 2 1/2" METAL

STUD AT 16" O.C. W/ BATT INSULATION

D6 INSULATED

5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL

STUD AT 16" O.C. W/ BATT INSULATION

INSULATED 3 3/4"

4 7/8"

7 1/4"5/8" GYPSUM BOARD EACH SIDE OF 6" METAL STUD

AT 16" O.C. W/ BATT INSULATION

E3 CARRIER --

TYPE MARK WALL TYPE DESCRIPTION WIDTH MIN. STC

E6

5/8" GYPSUM BOARD ONE SIDE OF (2) 3 5/8" METAL

STUD AT 16" O.C. WALLS W/ BATT INSULATION ONE

SIDE

1'-8"

--2'-0 3/4"CARRIER 5/8" GYPSUM BOARD ONE SIDE OF (2) 3 5/8" METAL

STUD AT 16" O.C. WALLS W/ BATT INSULATION ONE

SIDE

F3 1 HR (UL U419) 49 STC

TYPE MARK WALL TYPE DESCRIPTION WIDTH MIN. STC

4 7/8"5/8" TYPE X GYPSUM BOARD EACH SIDE OF 3 5/8"

METAL STUD AT 16" O.C.

F3 1 HR (UL XXX) XX STC4 7/8"5/8" TYPE X GYPSUM BOARD EACH SIDE OF 6"

METAL STUD AT 16" O.C.

G2 1 HR (U415/U469) 5/8" TYPE X GYPSUM BOARD ONE SIDE & 1" TYPE X

GYPSUM BOARD OPPOSITE SIDE OF 2 1/2" CH

METAL STUD AT 16" O.C. W/ BATT INSULATION

3 1/8" U415 - 45 STC

U469 - 39 STC

TYPE MARK WALL TYPE DESCRIPTION WIDTH MIN. STC

G4 1 HR (U415/U469) 5/8" TYPE X GYPSUM BOARD ONE SIDE & 1" TYPE X

GYPSUM BOARD OPPOSITE SIDE OF 4" CH METAL

STUD AT 16" O.C. W/ BATT INSULATION

4 5/8" 45 STC

G6 1 HR (U415/U469) 5/8" TYPE X GYPSUM BOARD ONE SIDE & 1" TYPE X

GYPSUM BOARD OPPOSITE SIDE OF 6" CH METAL

STUD AT 16" O.C. W/ BATT INSULATION

6 5/8" 45 STC

BATT INSULATION

5/8" TYPE X GYPSUM BOARD

H3 1 HR / SMOKE 5/8" TYPE X GYPSUM BOARD EACH SIDE OF 3 5/8"

METAL STUD AT 16" O.C.

4 7/8" 45 STC

TYPE MARK WALL TYPE DESCRIPTION WIDTH MIN. STC

H6 1 HR / SMOKE 5/8" TYPE X GYPSUM BOARD EACH SIDE OF 6"

METAL STUD AT 16" O.C.

7 1/4" 45 STC

J2 2 HR (UL U411) 2 LAYERS 5/8" TYPE X GYPSUM BOARD EACH SIDE

OF 2 1/2" METAL STUD AT 16" O.C.

5" 51 STC

TYPE MARK WALL TYPE DESCRIPTION WIDTH MIN. STC

J3 6 1/8"2 HR (UL W404) 2 LAYERS 5/8" TYPE X GYPSUM BOARD EACH SIDE

OF 2 1/2" METAL STUD AT 16" O.C.

J3 8 1/2"2 HR (UL W404) 2 LAYERS 5/8" TYPE X GYPSUM BOARD EACH SIDE

OF 2 1/2" METAL STUD AT 16" O.C.

51 STC

51 STC

K2 2 HR (U415/U438) 2 LAYERS 5/8" TYPE X GYPSUM BOARD ONE SIDE &

1" TYPE X GYPSUM BOARD ONE SIDE OF 2 1/2" CH

METAL STUD AT 16" O.C.

3 1/2" 47 STC

TYPE MARK WALL TYPE DESCRIPTION WIDTH MIN. STC

K4 2 HR (U415/U438) 2 LAYERS 5/8" TYPE X GYPSUM BOARD ONE SIDE &

1" TYPE X GYPSUM BOARD ONE SIDE OF 4" CH

METAL STUD AT 16" O.C.

5" 47 STC

K6 2 HR (U415/U438) 2 LAYERS 5/8" TYPE X GYPSUM BOARD ONE SIDE &

1" TYPE X GYPSUM BOARD ONE SIDE OF 6" CH

METAL STUD AT 16" O.C.

7 1/4" 47 STC

1. PAINT CONTINUOUS 4" TALL, STENCILED LETTERS, ABOVE CEILING, ON BOTH SIDES OF ALL FIRE AND

SMOKE WALLS DESIGNATING THE PARTITION RATING INDICATED ON THE LIFE SAFETY PLAN.

2. REFER TO FINISH SCHEDULE AND INTERIOR ELEVATIONS FOR LOCATIONS OF ALL WALL TILE.

PROVIDE AND INSTALL CEMENTITIOUS BACKER BOARD IN LIEU OF GWB AT ALL SCHEDULED TILE LOCATIONS. UNLESS NOTED OTHERWISE, TILE SHALL BE INSTALLED PER TILE COUNCIL OF AMERICA LATEST STANDARDS FOR EACH TYPE OF BACKING MATERIAL REPRESENTED IN WALL/PARTITION.

3. ALL SUSPENDED WALLS AND PARTITIONS SHALL HAVE GWB WHICH EXTENDS A MINIMUM OF 6" ABOVE

THE SUSPENDED CEILING UNLESS SHOWN AND/OR NOTED OTHERWISE BY THE ARCHITECT.

4. REFER TO STRUCTURAL DRAWINGS FOR ALL LOAD BEARING WALL CONDITIONS IN REGARDS TO

STRUCTURAL REQUIREMENTS.

5. "ALIGN" MEANS SIMILAR COMPONENTS OF CONSTRUCTION, E.G. WALLS, JAMBS, ETC. SHALL ALIGN

ACROSS VOIDS AND JOINTS.

6. PARTITIONS SHALL BE CONTINUOUS OVER DOORS SAME ADJACENT WALLS (UNLESS NOTED

OTHERWISE) WHERE DRYWALL CONTINUES ABOVE CEILING AND ABOVE THE CEILING LEVEL UP TO

THE STRUCTURE ABOVE. ALL GYPSUM BOARD RETURNS SHALL HAVE CORNER BEADS MINIMUM

FLOOR TO CEILING. ALL PENETRATIONS IN DRYWALL CONSTRUCTION ABOVE FINISHED CEILING SHALL BE EFFECTIVELY SEALED TO PREVENT SOUND LEAKAGE AND FIRE STOPPING TAPE/CAULK AT ALL

RATED PARTITIONS.

7. ALL MECHANICAL CHASES AND OTHER NOTED CHASES ARE TO EXTEND UP TO THE UNDERSIDE OF THE DECK STRUCTURE ABOVE. ALL PLUMBING CHASES UNLESS OTHERWISE NOTED, SHALL EXTEND

ABOVE THE HIGHEST ADJOINING CEILING AND BE BRACED TO STRUCTURE.

8. ALL CONSTRUCTION DESIGNATED TO BE SUPPORTED BY ROOF STRUCTURE SHALL BE SUPPORTED

BY TOP CHORD OF STRUCTURAL JOISTS AND NOT FROM THE METAL DECK.

9. COORDINATE WITH MILLWORK DRAWINGS FOR PLACEMENT OF BLOCKING IN WALLS/PARTITIONS. ALL

WOOD BLOCKING IS TO BE FIRE RETARDANT TREATED.

10. IMPACT RESISTANT GWB, WHERE NOTED, IS OPTIONAL ABOVE 8' AFF AND BEHIND LOCKERS.

11. SEAL THE TOP AND BOTTOM OF WALL AS WELL AS ALL PENETRATIONS WHERE SMOKE PARTITIONS

ARE DESIGNATED ON THE LIFE SAFETY PLAN TO ELIMINATE THE PASSAGE OF SMOKE.

12. USE DEFLECTION TRACKS WHERE STUD WALLS ATTACH DIRECTLY TO METAL DECK.

GENERAL PARTITION NOTES

UNDERSIDE OF STRUCTURE

FIRE RATED SEALANT AROUND PERIMETER

DIM DIM

DEFLECTION TRACK WHERE NEEDED

TYPICAL DEFLECTION TRACK

*FIRESTOP ALL PENETRATIONS

WALL PRIORITY PLAN & LEGEND

2- H

R R

A T

E D

W A

LL

NON-RATED

WALL

RATED WALL

N O

N -R

A T

E D

W

A

LL

1-HR RATED

WALL

2-HR RATED

WALL

1-HR RATED

WALL

ONE (1) LAYER

OF GYP. BD. AT

1-HR RATED

WALL

HOLLOW METAL FRAME

JAMB STUDS AS

REQUIRED

HIGHER PRIORITY WALL

METAL STUDS PER

WALL TYPE

TWO HOUR FIRE & SMOKE WALL PRIORITY 1 (HIGHEST)

TWO HOUR FIRE WALL PRIORITY 2

TWO HOUR SHAFT WALL PRIORITY 2

ONE HOUR FIRE & SMOKE WALL PRIORITY 3

ONE HOUR FIRE WALL PRIORITY 4

NON-RATED WALL PRIORITY 5 (LOWEST)

2" M

A X

2"MAX.

BASIC PARTITION

ASSEMBLY CATEGORY

FRAMING UNIT

SIZE CATEGORY

PARTITION TAG

PARTITION

PER PLAN

TYPICAL PARTITION TAG A3

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR SBBL COLLABORATIVE JN, INC.

100 N. STONE AVE STE 1102

TUCSON, AZ 85701-1524

(520) 620-0255

NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023

NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024

NM ELEC - EVANS SORDIASHIE #22917 EXP. 12/31/2023

CIVIL / STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

2519 MADISON AVE

KANSAS CITY, MO 64108

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

HEALTHCARE PLANNER

THE INNOVA GROUP

3196 NORTH SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:4

:3

A

M

PARITION TYPES

NR 32 79AJS

BID DOCUMENTS

REPAIR SPS SEWER AND

UPGRADE EQUIPMENT AREA

08/11/2023

501-21-101

RAYMOND G. MURPHY VAMC

1501 SAN PEDRO DRIVE SE

ALBUQUERQUE, NM 87108

AE021

SPUR #: 1993.10

1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS OTHERWISE NOTED

2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE CONSTRUCTION

DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL CONSTRUCTION

DOCUMENTS OF THE FACILITY.

3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE UTILIZING

HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.

4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OT AREA HAS BEEN

INSPECTED BY THE SAVAHCS SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND

THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES

5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND

CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW CONSTRUCTION.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE CAUSED BY HIS

WORK OR ANY SUBCONTRACTOR.

6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND MAINTAIN FLOOR TO

CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR DUE TO EXISTING

CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.

7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.

8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO ROOMS OUTSIDE OF

SCOPE WITH OWNER

10. CONTRACTOR TO CATALOG, RELOCATE, AND PROTECT ALL EQUIPMENT DURING CONSTRUCTION.

ALL EQUIPMENT TO BE REINSTALLED IN EXISTING LOCATIONS AFTER CONSTRUCTION. COORDINATE

WITH VA.

GENERAL DEMOLITION NOTES

2 3 4 5 6 7

G

H

I

2.06

2.05

4'-2"

4'-2"

RECEPTION AND

PGM ASST

BC-125

OFFICE OF CHIEF

BIOMED

BC-125A

MECH RM

BC-126B

SOILED RECV &

DECONTAMINATION

BC-110

STOR

BC-127

STERILIZATION

PREPARATION

BC-111

EQUIP TEST &

STORAGE

BC-115D

WORK AREA &

STOR

BC-115C

BIOMED WORK

SPACE

BC-125D

OFFICE

BC-115E

BREAKDOWN

BC-115B

HALL

BC-103A

BREAK ROOM

BC-103B

TLT (F)

BC-115G

TLT

BC-104

TLT

BC-105

STOR

BC-118

RECEPTION

BC-121A

MED SUPPLY TECH

BC-121B

OFFICE

BC-123

HAC

BC-115A

STOR

BC-119

MECH

BC-115F

LOCKERS

BC-102

CORRIDOR

CB-15

CART WASH

BC-114

C O

R R

ID

O

R

C B

-1

SPS CHANGE AREA

BC-103

DUMBWAITER

X1

HLD DECON

BC-110B

FACILTY ACCESS

STAIRWELL

S11

TLT

BC-102A

CORRIDOR

CB-17

TECHNICAL WORK

SPACE

BC-126

PARTS RM

BC-126A

MED GAS

BC-121

CORRIDOR

M E

D G

A S

S T

O R

B C

-1

DOCK

CORRIDOR

CORRIDOR

112'-6"

22'-6" 22'-6" 22'-6" 22'-6" 22'-6"

8'

-0

'-0

'-0

7'-6"

2' -0

2.07

HLD ALCOVE

BC-110C

HLD ANTEROOM

BC-110A

OFFICE

BC-103C

STAFF WORK AREA

BC-115

2.03 4' -2

2.02

2.08

2.09

2.092.09

2.08

2.092.09

2.092.09

VEST

BC-111A

2.11

2.09

2.092.09

2.082.08

2.08

2.082.08

2.08

2.08

2.08

2.08

2.092.09

2.03

2.032.03

2.032.03

6"

4'-10"

2.13

2.13 2.12

EXISITING WINDOW & FRAME TO

BE DEMOLISHED IN ITS ENTIRETY

EXISITNG DOOR & FRAME TO BE

DEMOLISHED IN ITS ENTIRETY

DEMOLITION FLOOR PLAN LEGEND

EXISTING WALL TO BE

DEMOLISHED IN ITS ENTIRETY

EXISTING WALLS TO REMAIN

EXISTING CEILING TILE AND

GRID TO BE DEMOLISHED

EXISTING GYPSUM BOARD

CEILING TO BE DEMOLISHED

EXISTING LIGHT FIXTURE

TO BE DEMOLISHED

DEMOLITION CEILING PLAN LEGEND

RETURN AIR GRILLE

TO BE DEMOLISHED

EXISTING SUPPLY AIR

DIFFUSER TO BE DEMOLISHED

EXISTING EXHAUST AIR GRILLE

TO BE DEMOLISHED

EXISTING CEILING TO REMAIN

EXISTING FLOOR FINISH

TO BE DEMOLISHED

EXISTING FLOOR ACCESS

PANELS TO BE DEMOLISHED

AREA NOT IN CONTRACT

EXISTING CEILING TILE AND

GRID TO BE DEMOLISHED

EXISTING LIGHT FIXTURE

TO BE DEMOLISHED

2 3 4 5 6 7

G

H

I

RECEPTION AND

PGM ASST

BC-125

OFFICE OF CHIEF

BIOMED

BC-125A

MECH RM

BC-126B

SOILED RECV &

DECONTAMINATION

BC-110

STOR

BC-127

STERILIZATION

PREPARATION

BC-111

EQUIP TEST &

STORAGE

BC-115D

WORK AREA &

STOR

BC-115C

BIOMED WORK

SPACE

BC-125D

OFFICE

BC-115E

BREAKDOWN

BC-115B

HALL

BC-103A

BREAK ROOM

BC-103B

TLT (F)

BC-115G

TLT

BC-104

TLT

BC-105

STOR

BC-118

STAFF WORK AREA

BC-115

RECEPTION

BC-121A

MED SUPPLY TECH

BC-121B

OFFICE

BC-123

HAC

BC-115A

STOR

BC-119

MECH

BC-115F

LOCKERS

BC-102

CORRIDOR

CB-15

CART WASH

BC-114

CORRIDOR

CB-16

SPS CHANGE AREA

BC-103

DUMBWAITER

X1

HLD DECON

BC-110B

FACILTY ACCESS

STAIRWELL

S11

TLT

BC-102A

CORRIDOR

CB-17

TECHNICAL WORK

SPACE

BC-126

PARTS RM

BC-126A

MED GAS

BC-121

CORRIDOR

M E

D G

A S

S T

O R

B C

-1

DOCK

CORRIDOR

CORRIDOR

112'-6"

22'-6" 22'-6" 22'-6" 22'-6" 22'-6"

8'

-0

'-0

'-0

OFFICE

BC-103C

HLD ALCOVE

BC-110C

HLD ANTEROOM

BC-110A

SPS DEPARTMENT

BUILDING 41

BASEMENT LEVEL, QUAD C

N

BUILDING 41 - BASEMENT LEVEL KEY PLAN

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR SBBL COLLABORATIVE JN, INC.

100 N. STONE AVE STE 1102

TUCSON, AZ 85701-1524

(520) 620-0255

NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023

NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024

NM ELEC - EVANS SORDIASHIE #22917 EXP. 12/31/2023

CIVIL / STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

2519 MADISON AVE

KANSAS CITY, MO 64108

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

HEALTHCARE PLANNER

THE INNOVA GROUP

3196 NORTH SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:4

:3

A

M

SPS - DEMOLITION FLOOR AND CEILING

PLAN

NR 33 79AJS

BID DOCUMENTS

REPAIR SPS SEWER AND

UPGRADE EQUIPMENT AREA

08/11/2023

501-21-101

RAYMOND G. MURPHY VAMC

1501 SAN PEDRO DRIVE SE

ALBUQUERQUE, NM 87108

AD100

SPUR #: 1993.10

N

1/8" = 1'-0"

BLDG 41, BASEMENT QUAD C - SPS DEPARTMENT - DEMOLITION FLOOR PLAN1

KEYNOTE LEGEND

2.02 REMOVE WALL AS REQUIRED FOR NEW CONSTRUCTION

2.03 REMOVE PLUMBING FIXTURES COMPLETELY. SEE PLUMBING DRAWINGS FOR ADDITIONAL

INFORMATION. EXISTING ELECTRICAL AND TELECOM ITEMS TO REMAIN.

2.05 REMOVE EXISTING CART WASH

2.06 REMOVE EXISTING ACCESS PANELS

2.07 WALK-OFF MAT

2.08 DEMOLISH ALL EXISTING WALL TILE AND EXISTING SUBSTRATE DOWN TO STUD.

2.09 DEMOLISH ALL EXISTING WALL PROTECTION AND EXISTING SUBSTRATE DOWN TO STUD.

2.11 EXISTING WASHER DISINFECTORS. CONTRACTOR TO RELOCATE AND PROTECT DURING

CONSTRUCTION. EQUIPMENT TO BE REINSTALLED IN EXISTING LOCATIONS AFTER

CONSTRUCTION. COORDINATE WITH VA.

2.12 REMOVE EXISTING CASEWORK AND RETAIN FOR REINSTALLATION AFTER CONSTRUCTION.

COORDINATE WITH VA.

2.13 REMOVE AND SALVAGE CASEWORK FOR REINSTALLATION OR DISPOSAL, PER VA

N

1/8" = 1'-0"

BLDG 41, BASEMENT QUAD C - SPS DEPARTMENT - DEMOLITION CEILING PLAN2

RECEPTION AND

PGM ASST

BC-125

OFFICE OF CHIEF

BIOMED

BC-125A

MECH RM

BC-126B

2 3 4 5 6 7

G

H

I

SOILED RECV &

DECONTAMINATION

BC-110

STOR

BC-127

STERILIZATION

PREPARATION

BC-111

EQUIP TEST &

STORAGE

BC-115D

WORK AREA &

STOR

BC-115C

OFFICE

BC-115E

BREAKDOWN

BC-115B

HALL

BC-103A

BREAK ROOM

BC-103B

TLT (F)

BC-115G

TLT

BC-104

TLT

BC-105

STOR

BC-118

STAFF WORK AREA

BC-115

RECEPTION

BC-121A

MED SUPPLY TECH

BC-121B

OFFICE

BC-123

HAC

BC-115A

STOR

BC-119

MECH

BC-115F

LOCKERS

BC-102

CORRIDOR

CB-15

CART WASH

BC-114

C O

R R

ID

O

R

C B

-1

SPS CHANGE AREA

BC-103

B C

-1

A B

C -1

D

DUMBWAITER

X1

HLD DECON

BC-110B

FACILTY ACCESS

STAIRWELL

S11

TLT

BC-102A

CORRIDOR

CB-17

TECHNICAL WORK

SPACE

BC-126

PARTS RM

BC-126A

MED GAS

BC-121

CORRIDOR

M E

D G

A S

S T

O R

B C

-1

DOCK

CORRIDOR

CORRIDOR

112'-6"

22'-6" 22'-6" 22'-6" 22'-6" 22'-6"

8'

-0

'-0

'-0

OFFICE

BC-103C

HAC

BC-110D

AE401

BIOMED WORK

SPACE

BC-125D

HLD ANTEROOM

BC-110A

HLD ALCOVE

BC-110C

C3B C

-1

L

BC-110D

22.06

22.08

22.09

22.10

AE402

AE402

AE402

AE40

AE402 1

AE4029

AE4027

AE4024

9.95

8.94

26.06

AE401

1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT

WALL UNLESS NOTED OTHERWISE.

2. ALL WALLS ARE TYPE C3 PARTITIONS UNLESS OTHERWISE NOTED.

REFER TO PARTITION TYPE SHEET FOR WALL TYPES.

3. ALL INFILLING WALLS TO MATCH THE THICKNESS OF THE INFILLING WALL UNLESS NOTED

OTHERWISE.

4. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE300) FOR DOOR INFORMATION.

5. REFER TO GLAZING ELEVATIONS & DETAILS SHEET (AE300) FOR WINDOW INFORMATION.

6. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.

7. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW TOLERANCE

FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.

8. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.

9. CONTRACTOR TO REMOVE AND RETAIN ALL SIGNAGE FOR REINSTALLATION AFTER CONSTRUCTION.

COORDINATE WITH VA.

10. REFER TO SHEET AE102 FOR EQUIPMENT SCHEDULE.

GENERAL PLAN NOTES

2 3 4 5 6 7

G

H

I

RECEPTION AND

PGM ASST

BC-125

OFFICE OF CHIEF

BIOMED

BC-125A

MECH RM

BC-126B

SOILED RECV &

DECONTAMINATION

BC-110

STOR

BC-127

STERILIZATION

PREPARATION

BC-111

EQUIP TEST &

STORAGE

BC-115D

WORK AREA &

STOR

BC-115C

OFFICE

BC-115E

BREAKDOWN

BC-115B

HALL

BC-103A

BREAK ROOM

BC-103B

TLT (F)

BC-115G

TLT

BC-104

TLT

BC-105

STOR

BC-118

RECEPTION

BC-121A

MED SUPPLY TECH

BC-121B

OFFICE

BC-123

HAC

BC-115A

STOR

BC-119

MECH

BC-115F

LOCKERS

BC-102

CORRIDOR

CB-15

CART WASH

BC-114

CORRIDOR

CB-16

SPS CHANGE AREA

BC-103

DUMBWAITER

X1

HLD DECON

BC-110B

FACILTY ACCESS

STAIRWELL

S11

TLT

BC-102A

TECHNICAL WORK

SPACE

BC-126

PARTS RM

BC-126A

MED GAS

BC-121

CORRIDOR

M E

D G

A S

S T

O R

B C

-1

DOCK

CORRIDOR

CORRIDOR

112'-6"

22'-6" 22'-6" 22'-6" 22'-6" 22'-6"

8'

-0

'-0

'-0

HAC

BC-110D

EQ 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" EQ

EQ 10'-0" 10'-0" 10'-0" EQ

10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 4'-9 1/2"

3'-9" 6'-5" 6'-5" 4'-0"

EQ 9'-6" 9'-6" 9'-6" 9'-6" 9'-6" EQ

4' -7

'-6

'-0

4'

-8

/2

4' -1

7'

-0

8' -0

8'

-0

3' -1

/2

4' -1

0"

'-0

7' -9

/2

3'

-2

/2

EQ EQ

E Q

7' -6

E

Q

E Q

E Q

HLD ALCOVE

BC-110C

HLD ANTEROOM

BC-110A

OFFICE

BC-103C

2'-2 1/2"

VEST

BC-111A

E Q

E Q

EQ EQ

4' -8

7'

-1

9' -0

VESTIBULE

BC-100

E Q

E Q

E Q

E Q

EQ 6'-6" EQ

EQ EQ

EQ 6'-6" EQ

E Q

E Q

4'-0" 6'-2" 4'-0"

STAFF WORK AREA

BC-115

BIOMED WORK

SPACE

BC-125D

CORRIDOR

CB-17

EQ EQ

4' -6

3'-4"

FLOOR PLAN LEGEND

EXISTING WALLS TO REMAINAREA NOT IN CONTRACT

2 x 2 LIGHT FIXTURE

REFLECTED CEILING PLAN LEGEND

RETURN AIR GRILLE

SUPPLY AIR DIFFUSER

NOTE: ALL SYMBOLS MAY NOT BE USED.

GYPSUM BOARD CEILING OR

SOFFIT

2 x 4 LIGHT FIXTURE

EXISTING CEILING TO REMAIN

EXHAUST AIR GRILLE

EXIT LIGHT OR SIGN

ACCESS PANEL

2 x 4 LIGHT FIXTURE

(EMERGENCY POWER)

1. ALL CEILINGS 9'-0" A.F.F. U.N.O.

2. ALL SURFACES OF FURRDOWNS TO BE PAINTED P1 U.N.O.

GENERAL REFLECTED CEILING PLAN NOTES

SPS DEPARTMENT

BUILDING 41

BASEMENT LEVEL, QUAD C

N

BUILDING 41 - BASEMENT LEVEL KEY PLAN

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR SBBL COLLABORATIVE JN, INC.

100 N. STONE AVE STE 1102

TUCSON, AZ 85701-1524

(520) 620-0255

NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023

NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024

NM ELEC - EVANS SORDIASHIE #22917 EXP. 12/31/2023

CIVIL / STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

2519 MADISON AVE

KANSAS CITY, MO 64108

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

HEALTHCARE PLANNER

THE INNOVA GROUP

3196 NORTH SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:4

:3

A

M

SPS - RENOVATION FLOOR AND CEILING

PLAN

KJW 34 79NR

BID DOCUMENTS

REPAIR SPS SEWER AND

UPGRADE EQUIPMENT AREA

08/11/2023

501-21-101

RAYMOND G. MURPHY VAMC

1501 SAN PEDRO DRIVE SE

ALBUQUERQUE, NM 87108

AE100

SPUR #: 1993.10

N

1/8" = 1'-0"

BLDG 41, BASEMENT QUAD C - SPS DEPARTMENT - RENOVATION FLOOR PLAN1

N

1/8" = 1'-0"

BLDG 41, BASEMENT QUAD C - SPS DEPARTMENT - RENOVATION CEILING PLAN2

KEYNOTE LEGEND

8.94 NEW FLOOR ACCESS PANELS. CONTRACTOR TO COORDINATE WITH FLOORING SUPPLIER

TO INTEGRATE A WATER PROOF SEAL.

9.95 CONTRACTOR TO PROVIDE 3 5/8" METAL STUD SUPPORT FOR CART WASH STAINLESS

STEEL PANELS.

22.06 SINK, AS SCHEDULED, SEE PLUMBING DRAWINGS

22.08 EYE WASH, AS SCHEDULED, SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION

22.09 MOP SINK, AS SCHEDULED, SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION

22.10 SAFETY SHOWER/EYE WASH COMBO, AS SCHEDULED, SEE PLUMBING DRAWINGS FOR

ADDITIONAL INFORMATION

26.06 POWER AND DATA POLE, REFER TO ELECTRICAL.

2 3 4 5 6 7

G

H

I

RECEPTION AND

PGM ASST

BC-125

OFFICE OF CHIEF

BIOMED

BC-125A

MECH RM

BC-126B

SOILED RECV &

DECONTAMINATION

BC-110

STOR

BC-127

STERILIZATION

PREPARATION

BC-111

EQUIP TEST &

STORAGE

BC-115D

WORK AREA &

STOR

BC-115C

BIOMED WORK

SPACE

BC-125D

OFFICE

BC-115E

BREAKDOWN

BC-115B

HALL

BC-103A

BREAK ROOM

BC-103B

TLT (F)

BC-115G

TLT

BC-104

TLT

BC-105

STOR

BC-118

STAFF WORK AREA

BC-115

RECEPTION

BC-121A

MED SUPPLY TECH

BC-121B

OFFICE

BC-123

HAC

BC-115A

STOR

BC-119

MECH

BC-115F

LOCKERS

BC-102

CORRIDOR

CB-15

CART WASH

BC-114

C O

R R

ID

O

R

C B

-1

SPS CHANGE AREA

BC-103

DUMBWAITER

X1

HLD DECON

BC-110B

FACILTY ACCESS

STAIRWELL

S11

TLT

BC-102A

CORRIDOR

CB-17

TECHNICAL WORK

SPACE

BC-126

PARTS RM

BC-126A

MED GAS

BC-121

CORRIDOR

M E

D G

A S

S T

O R

B C

-1

DOCK

CORRIDOR

CORRIDOR

112'-6"

22'-6" 22'-6" 22'-6" 22'-6" 22'-6"

8'

-0

'-0

'-0

OFFICE

BC-103C

K1910

HAC

BC-110D

VESTIBULE

BC-100

HLD ALCOVE

BC-110C

HLD ANTEROOM

BC-110A

S3185

22.09

A5075

A5080

AE401

U0001U0001

U1195 U1196

A1195A1195

F0505

A5135

22.08

22.08

12.19

SPS DEPARTMENT

BUILDING 41

BASEMENT LEVEL, QUAD C

N

BUILDING 41 - BASEMENT LEVEL KEY PLAN

GENERAL EQUIPMENT NOTES

1. CONTRACTOR TO CATALOG, RELOCATE, AND PROTECT ALL EQUIPMENT DURING CONSTRUCTION UNLESS OTHERWISE NOTED ON PLAN. ALL EQUIPMENT TO BE REINSTALLED IN EXISTING LOCATIONS

AFTER CONSTRUCTION. COORDINATE WITH VA.

V / V GOVERNMENT FURNISHED / GOVERNMENT INSTALLED

V / C GOVERNMENT FURNISHED / CONTRACTOR INSTALLED

C / C CONTRACTOR FURNISHED / CONTRACTOR INSTALLED

R REUSED

ACQUISITION CODE LEGEND

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR SBBL COLLABORATIVE JN, INC.

100 N. STONE AVE STE 1102

TUCSON, AZ 85701-1524

(520) 620-0255

NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023

NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024

NM ELEC - EVANS SORDIASHIE #22917 EXP. 12/31/2023

CIVIL / STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

2519 MADISON AVE

KANSAS CITY, MO 64108

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

HEALTHCARE PLANNER

THE INNOVA GROUP

3196 NORTH SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:4

:4

A

M

SPS - RENOVATION PLANS - EQUIPMENT

KJW 35 79NR

BID DOCUMENTS

REPAIR SPS SEWER AND

UPGRADE EQUIPMENT AREA

08/11/2023

501-21-101

RAYMOND G. MURPHY VAMC

1501 SAN PEDRO DRIVE SE

ALBUQUERQUE, NM 87108

AE102

SPUR #: 1993.10

N

1/8" = 1'-0"

BLDG 41, BASEMENT QUAD C - SPS DEPARTMENT - EQUIPMENT FLOOR PLAN1

EQUIPMENT SCHEDULE

TYPE DESCRIPTION ACQUISITION CODE

A1195 COUNTER, CLEANUP, WITH 2 OR 3 SINKS C / C

A5075 DISPENSER, SOAP, DISPOSABLE V / V

A5080 DISPENSER, PAPER TOWEL, SS, SURFACE MOUNTED C / C

A5135 SHELF, UTLILITY W/ MOP/ BROOM HOLDERS, SS, SURF MNTD C / C

F0505 BUCKET, MOP, WITH WRINGER, 26 QUART V / V

K1910 TABLE, WORK, STAINLESS STEEL V / V

M2600 VACUUM, WET/DRY, HEPA FILTRATION V / V

S3185 WASHER, CART & UTENSIL, 2 DO, PIT MNTD, RCSD 2 WLL C / C

U0001 CLEANER/OILER, DENTAL V / V

U0003 DISPENSING SYSTEM, CLEANING PRODUCT V / V

U0004 VERTICAL PLATFORM LIFT C / C

U0005 SAFETY CHAIN C / C

U0006 FULL DOME SAFETY MIRROR C / C

U0007 QUARTER DOME SAFETY MIRROR C / C

U1195 COUNTER, CLEANUP, WITH 2 SINKS C / C

U1196 COUNTER, CLEANUP, WITH 3 SINKS C / C

KEYNOTE LEGEND

12.19 REINSTALL STAINLESS STEEL CASEWORK. COORDINATE WITH VA.

22.08 EYE WASH, AS SCHEDULED, SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION

22.09 MOP SINK, AS SCHEDULED, SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION

F

SCHED. DIM.

S C

H E

D . D

IM

FFE

FLUSH

NOTES

1. 1/4" FIRE GLASS AT RATED DOORS

- TEMPERED GLAZING

SCHED. DIM.

S C

H E

D . D

IM

. 2' -0

4'

-0

6" 4"

S C

H E

D . D

IM

4' -0

2'

-6

6" VARIES 6"

SCHED. DIM.

NL

NARROW LITE

PAIR - HL

HALF LITE

A

2" 5/

8"

1 15/16" VARIES 1 9/16"

1/2"

INT. STUD WALLS

WALL THICKNESS AT 1/2"

RE: DOOR SCHEDULE

FRAME DEPTH

HM-1

2" S

C H

E D

. D

IM

2"

DIM.

SCHED. 2"

FFE

STANDARD FRAME

INTERIOR DETAILS:

HEAD:

JAMB:

EXTERIOR DETAILS:

HEAD:

JAMB:

2.01

8.95

F V

FV FV

F V

8.95 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR SBBL COLLABORATIVE JN, INC.

100 N. STONE AVE STE 1102

TUCSON, AZ 85701-1524

(520) 620-0255

NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023

NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024

NM ELEC - EVANS SORDIASHIE #22917 EXP. 12/31/2023

CIVIL / STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

2519 MADISON AVE

KANSAS CITY, MO 64108

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

HEALTHCARE PLANNER

THE INNOVA GROUP

3196 NORTH SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:4

:4

A

M

DOOR DETAILS AND EXTERIOR

ELEVATION

KJW 36 79NR

BID DOCUMENTS

REPAIR SPS SEWER AND

UPGRADE EQUIPMENT AREA

08/11/2023

501-21-101

RAYMOND G. MURPHY VAMC

1501 SAN PEDRO DRIVE SE

ALBUQUERQUE, NM 87108

AE300

SPUR #: 1993.10

DOOR SCHEDULE

MARK ROOM NAME

DOOR- TYPE

DOOR PANEL WALL

THICKNESS

FRAME HARDWA

RE SET

COMMENTS

MATERIAL WIDTH HEIGHT FIRE RATING TYPE FINISH

103A ENTRY PAIR-F MTL 6'-0" 7'-0" - 10" HM-1 PAINTED ACM714 MIN U VALUE OF U-03.70

103B CORRIDOR F MTL 3'-0" 7'-0" - 10" HM-1 PAINTED CM715

BC-110D HAC F MTL 3'-0" 7'-0" - 4 7/8" HM-1 PAINTED 201

BC-115A SPS CHANGE AREA F MTL 4'-0" 7'-0" - 5" HM-1 PAINTED 201W

BC-115D WORK AREA & STOR F MTL 4'-0" 7'-0" - 5" HM-1 PAINTED 101W

BC-115L

SOILED RECV &

DECONTAMINATION

PAIR-HL

MTL 6'-0" 7'-0" - 4 7/8" HM-1 PAINTED A800G

1/4" = 1'-0"

DOOR TYPES4

3" = 1'-0"

DOOR FRAME PROFILES3 1/4" = 1'-0"

HOLLOW METAL FRAME TYPES2

No. REVISION DESCRIPTION DATE

3/8" = 1'-0" 4/ A-001

BUILDING 45 EXTERIOR ELEVATION1

KEYNOTE LEGEND

2.01 EXISTING TO REMAIN

8.95 EXISTING METAL LOUVERS TO BE REPLACED WITH 90-MINUTE FIRE RATED LOUVERS.

CONTRACTOR TO VERIFY SIZE AND INSTALL PER MANUFACTURER RECOMMENDATIONS.

AE4016 3

BC-110D

HAC

BC-110D

F0505

A5135

M2600

22.09

9"

C3

C3

A3

A5075

A5080

U0003 6"

4' -0

4'

-6

9' -0

A5135

CT1

P1

RES1

22.09

4' -6

4'

-6

9"

4'-0" 4'-3"

FV

8'-3"

22.08

3'-0"

4' -6

4'

-0

6"

9' -0

CT1

P1

RES1

22.09

4' -6

4'

-6

1'-2"3'-7"

FV

4'-9"

6" 4'

-0

4' -6

9' -0

CT1

P1

RES1

4' -6

4'

-6

FV

4'-9"

B C

-1

D

6" 4'

-0

4' -6

CT1

P1

RES1

22.08

9' -0

4' -6

4'

-6

1. REFERENCE SHEET G1001 - GENERAL INFORMATION - FOR ACCESSORY MOUNTING HEIGHTS

GENERAL ELEVATION NOTES

V / V GOVERNMENT FURNISHED / GOVERNMENT INSTALLED

V / C GOVERNMENT FURNISHED / CONTRACTOR INSTALLED

C / C CONTRACTOR FURNISHED / CONTRACTOR INSTALLED

R REUSED

ACQUISITION CODE LEGEND

3A

6" 3'

-6

4' -0

6" 4'

-0

"RWC1

WSF1

P1

WSF1

8'-3 1/2" 4'-7"

FV

12'-10 1/2"

9.33

4' -0

6"

3' -6

RWC1

WSF1

P1

RWC1

WSF1

RWC1

WSF1

P1

CG2

U0005

U0007

4' -0

6"

6" 3'

-6

4' -0

5'-2" 8'-3 1/2"

RWC1

WSF1

P1

WSF1

U0004

WSF1

FV

13'-6"

RWC1

9.33

AE4019 10

CORRIDOR

103A

ENTRY

11 U0004

U0005

AE401

6" 3'

-6

4' -0

FV

9'-10 1/2"

RWC1

WSF1

P1

9.33

4' -0

6"

4' -6

" RWC1

P1

9.29

RES1 (RESINOUS FLOOR

INTEGRAL BASE)

ELEVATION LEGEND

RWC1 (RIGID VINYL

WALLCOVERING)

CT1 (CERAMIC TILE)

SWC1 (STAINLESS STEEL

WALLCOVERING)

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR SBBL COLLABORATIVE JN, INC.

100 N. STONE AVE STE 1102

TUCSON, AZ 85701-1524

(520) 620-0255

NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023

NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024

NM ELEC - EVANS SORDIASHIE #22917 EXP. 12/31/2023

CIVIL / STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

2519 MADISON AVE

KANSAS CITY, MO 64108

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

HEALTHCARE PLANNER

THE INNOVA GROUP

3196 NORTH SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:4

:4

A

M

INTERIOR ELEVATIONS AND ENLARGED

PLANS

CLW 37 79NR

BID DOCUMENTS

REPAIR SPS SEWER AND

UPGRADE EQUIPMENT AREA

08/11/2023

501-21-101

RAYMOND G. MURPHY VAMC

1501 SAN PEDRO DRIVE SE

ALBUQUERQUE, NM 87108

AE401

SPUR #: 1993.10

N

3/8" = 1'-0"

HAC BC-110D ENLARGED PLAN13/8" = 1'-0" 1/ AE401

HAC BC-110D EAST ELEVATION33/8" = 1'-0" 1/ AE401

HAC BC-110D NORTH ELEVATION43/8" = 1'-0" 1/ AE401

HAC BC-110D SOUTH ELEVATION5

3/8" = 1'-0" 1/ AE401

HAC BC-110D WEST ELEVATION6

KEYNOTE LEGEND

9.29 BASE AS SCHEDULED

9.33 APPLY COLOR MATCHED CAULK AT JOINTS

22.08 EYE WASH, AS SCHEDULED, SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION

22.09 MOP SINK, AS SCHEDULED, SEE PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION

EQUIPMENT SCHEDULE

TYPE DESCRIPTION ACQUISITION CODE

A1195 COUNTER, CLEANUP, WITH 2 OR 3 SINKS C / C

A5075 DISPENSER, SOAP, DISPOSABLE V / V

A5080 DISPENSER, PAPER TOWEL, SS, SURFACE MOUNTED C / C

A5135 SHELF, UTLILITY W/ MOP/ BROOM HOLDERS, SS, SURF MNTD C / C

F0505 BUCKET, MOP, WITH WRINGER, 26 QUART V / V

K1910 TABLE, WORK, STAINLESS STEEL V / V

M2600 VACUUM, WET/DRY, HEPA FILTRATION V / V

S3185 WASHER, CART & UTENSIL, 2 DO, PIT MNTD, RCSD 2 WLL C / C

U0001 CLEANER/OILER, DENTAL V / V

U0003 DISPENSING SYSTEM, CLEANING PRODUCT V / V

U0004 VERTICAL PLATFORM LIFT C / C

U0005 SAFETY CHAIN C / C

U0006 FULL DOME SAFETY MIRROR C / C

U0007 QUARTER DOME SAFETY MIRROR C / C

U1195 COUNTER, CLEANUP, WITH 2 SINKS C / C

U1196 COUNTER, CLEANUP, WITH 3 SINKS C / C

No. REVISION DESCRIPTION DATE

3/8" = 1'-0" 2/ AE401

ENTRY 101 WEST ELEVATION9

3/8" = 1'-0" 2/ AE401

ENTRY 101 NORTH ELEVATION8

3/8" = 1'-0" 2/ AE401

ENTRY 101 EAST ELEVATION10

N

3/8" = 1'-0"

ENTRY 101 ENLARGED PLAN2

3/8" = 1'-0" 2/ AE401

ENTRY 101 SOUTH ELEVATION11

3/8" = 1'-0" 1/ AE100

TYPICAL RIGID VINYL WALL (RWC1) PROTECTION7

G

F V

9' -0

3'-8" 2'-7 1/2" 1'-11 1/2"

FV

6'-3 1/2"

6" 8'

-6

SWC1

G

FV

8'-0"

VIEW

ANGLED

6" 8'

-6

F V

9' -0

CG1

SWC1

VIEW

ANGLED

FV

4'-4 1/2"

F V

9' -0

6" 8'

-6

SWC1

S3185

F V

9' -0

9.95

FV

13'-0 1/2"

19'-8"22'-2 1/2"

VIEW

ANGLED

FV

41'-10 1/2"

F V

9' -0

6" 8'

-6

SWC1

11.04 11.04 11.04

FV

5'-5"

F V

9' -0

6" 8'

-6

SWC1

S3185

3'-0" 13'-0" 3'-1"

6" 8'

-6

F V

9' -0

FV

19'-1"

9.95

SWC1SWC1

VIEW

ANGLED FV

9'-6"

F V

9' -0

6" 8'

-6

SWC1

F V

9' -0

FV

41'-4 1/2"

8' -6

6"

9'-6" 10'-0" 21'-11"

SWC1

11.04 11.0411.0411.04

1. REFERENCE SHEET G1001 - GENERAL INFORMATION - FOR ACCESSORY MOUNTING HEIGHTS

GENERAL ELEVATION NOTES

VIEW

ANGLED

FV

3'-3 1/2"

F V

9' -0

6" 8'

-6

SWC1

V / V GOVERNMENT FURNISHED / GOVERNMENT INSTALLED

V / C GOVERNMENT FURNISHED / CONTRACTOR INSTALLED

C / C CONTRACTOR FURNISHED / CONTRACTOR INSTALLED

R REUSED

ACQUISITION CODE LEGEND

RES1 (RESINOUS FLOOR

INTEGRAL BASE)

ELEVATION LEGEND

RWC1 (RIGID VINYL

WALLCOVERING)

CT1 (CERAMIC TILE)

SWC1 (STAINLESS STEEL

WALLCOVERING)

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR SBBL COLLABORATIVE JN, INC.

100 N. STONE AVE STE 1102

TUCSON, AZ 85701-1524

(520) 620-0255

NM ARCH - SETH CAVIN #005667 EXP. 12/31/2023

NM MECH - JAMES R. MYLES #25930 EXP. 12/31/2024

NM ELEC - EVANS SORDIASHIE #22917 EXP. 12/31/2023

CIVIL / STRUCTURAL ENGINEER

H2B, INC.

1225 N. LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

2519 MADISON AVE

KANSAS CITY, MO 64108

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

HEALTHCARE PLANNER

THE INNOVA GROUP

3196 NORTH SWAN ROAD

TUCSON, AZ 85712

(520) 886-8650

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:4

:4

A

M

INTERIOR ELEVATIONS AND ENLARGED

PLANS

CLW 38 79NR

BID DOCUMENTS

REPAIR SPS SEWER AND

UPGRADE EQUIPMENT AREA

08/11/2023

501-21-101

RAYMOND G. MURPHY VAMC

1501 SAN PEDRO DRIVE SE

ALBUQUERQUE, NM 87108

AE402

SPUR #: 1993.10

3/8" = 1'-0" 1/ AE100

STAINLESS STEEL WALL PROTECTION ELEVATION 11

3/8" = 1'-0" 1/ AE100

STAINLESS STEEL WALL PROTECTION ELEVATION 99

3/8" = 1'-0" 1/ AE100

STAINLESS STEEL WALL PROTECTION ELEVATION 77

3/8" = 1'-0" 1/ AE100

STAINLESS STEEL WALL PROTECTION ELEVATION 33

3/8" = 1'-0" 1/ AE100

STAINLESS STEEL WALL PROTECTION ELEVATION 66

3/8" = 1'-0" 1/ AE100

STAINLESS STEEL WALL PROTECTION ELEVATION 55

3/8" = 1'-0" 1/ AE100

STAINLESS STEEL WALL PROTECTION ELEVATION 88

3/8" = 1'-0" 1/ AE100

STAINLESS STEEL WALL PROTECTION ELEVATION 22

3/8" = 1'-0" 1/ AE100

STAINLESS STEEL WALL PROTECTION ELEVATION 1010

KEYNOTE LEGEND

9.95 CONTRACTOR TO PROVIDE 3 5/8" METAL STUD SUPPORT FOR CART WASH STAINLESS STEEL

PANELS.

11.04 COORDINATE REINSTALLATION OF EQUIPMENT WITH VA.

EQUIPMENT SCHEDULE

TYPE DESCRIPTION ACQUISITION CODE

A1195 COUNTER, CLEANUP, WITH 2 OR 3 SINKS C / C

A5075 DISPENSER, SOAP, DISPOSABLE V / V

A5080 DISPENSER, PAPER TOWEL, SS, SURFACE MOUNTED C / C

A5135 SHELF, UTLILITY W/ MOP/ BROOM HOLDERS, SS, SURF MNTD C / C

F0505 BUCKET, MOP, WITH WRINGER, 26 QUART V / V

K1910 TABLE, WORK, STAINLESS STEEL V / V

M2600 VACUUM, WET/DRY, HEPA FILTRATION V / V

S3185 WASHER, CART & UTENSIL, 2 DO, PIT MNTD, RCSD 2 WLL C / C

U0001 CLEANER/OILER, DENTAL V / V

U0003 DISPENSING SYSTEM, CLEANING PRODUCT V / V

U0004 VERTICAL PLATFORM LIFT C / C

U0005 SAFETY CHAIN C / C

U0006 FULL DOME SAFETY MIRROR C / C

U0007 QUARTER DOME SAFETY MIRROR C / C

U1195 COUNTER, CLEANUP, WITH 2 SINKS C / C

U1196 COUNTER, CLEANUP, WITH 3 SINKS C / C

3/8" = 1'-0" 1/ AE100

STAINLESS STEEL WALL PROTECTION ELEVATION 44

WSF1 (WELDED SHEET FLOOR)

FLOOR FINISH LEGEND

RES1 (RESINOUS FLOOR) AREA NOT IN CONTRACT

CG1 (CORNERGUARD)

ETR (EXISTING TO REMAIN)

CG1 (CORNERGUARD)

CG2

RECEPTION AND

PGM ASST

BC-125

OFFICE OF CHIEF

BIOMED

BC-125A

MECH RM

BC-126B

SOILED RECV &

DECONTAMINATION

BC-110

STOR

BC-127

STERILIZATION

PREPA…