Attachment D - Gen Drawings.pdf
PDF 4 MB Posted
- Solicitation number
- 36C26224B0001_1
About this file
This document package includes drawings and specifications for a roof replacement and lightning protection project. The project involves replacing the existing PVC roofing system with a new TPO roofing system at the Veterans Affairs Loma Linda Medical Center located in Loma Linda, California. Work will be performed at the main hospital building and will include roof demolition, installation of a new roof system, and installation of a new lightning protection system. Bidders are required to provide all labor, equipment, materials, and supervision to complete the project in accordance with the design drawings and specifications. The project is to be completed while the hospital remains operational, requiring infection control measures and coordination of utility shutdowns.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
PROJECT SITE MAP PROJECT LOCATION MAP
PROJECT IMAGE
/1 /2
:2
:4
P M
C U s e rs
\o m a n ts c h \D o c u m e n ts
\R e v it L o c a l\ A
G I_
-3
-V
A L o m a L in d a R e p la c e
R o o f_ o m a n ts c h
.r v t
G-001
COVER SHEET
1 3OKM
ROOF REPLACEMENT AND
LIGHTNING PROTECTION
VA LOMA LINDA HEALTHCARE SYSTEM
11201 BENTON ST, LOMA LINDA,
CA 92357 DECEMBER 20, 2023
100% BID DOCUMENTS
605-20-41121-330-Q31
ROOF REPLACEMENT AND LIGHTNING
PROTECTION
VA LOMA LINDA HEALTHCARE SYSTEM
11201 BENTON ST, LOMA LINDA,
CA 92357
VA PROJECT #: 605-20-411
TM
VA MEDICAL CENTER
DRAWING LIST
GENERAL
G-001 COVER SHEET 1 3
G-002 GENERAL INFORMATION 2 3
GC100 GENERAL SITE INFORMATION 3 3
ARCHITECTURAL
AG001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND NOTES 1 10
AD101 ROOF DEMOLITION PLAN - MAIN BUILDING 2 10
AD102 ROOF DEMOLITION PLAN - CLC & ANNEX 3 10
AE101 ROOF PLAN - MAIN BUILDING 4 10
AE102 ROOF PLAN - CLC & ANNEX 5 10
AE401 PHOTOS MAIN HOSPITAL BUILDING 6 10
AE402 PHOTOS ANNEX BUILDING 7 10
AE403 PHOTOS CLC BUILDING 8 10
AE501 TYPICAL ROOF DETAILS 9 10
AE502 TYPICAL ROOF DETAILS 10 10
ELECTRICAL
E-001 ELECTRICAL GENERAL NOTES, SYMBOL LEGENDS, AND ABBREVIATIONS 1 7
ED101 ELECTRICAL ROOF DEMOLITION PLAN 2 7
ED102 ROOF ELECTRICAL DEMOLITION PLANS - CLC & ANNEX 3 7
EG101 ROOF ELECTRICAL - LIGHTNING PROTECTION PLAN 4 7
EG102 ROOF ELECTRICAL - LIGHTNING PROTECTION PLAN - CLC & ANNEX 5 7
E-401 ELECTRICAL ENLARGEMENTS 6 7
E-501 ELECTRICAL LIGHTNING PROTECTION DETAILS 7 7
VA MEDICAL
CENTER
DocuSign Envelope ID: 6043734F-C02F-4C86-A533-C1342BFCF722
12/22/2023
WALL SECTION
SYMBOL
INTERIOR ELEVATION
SYMBOL
COLUMN GRID
ELEVATION SYMBOL
REVISION NOTE
ENLARGED DETAIL CALLOUT
ROOM DESIGNATION
SYMBOL
BREAK LINE
ROOF SLOPE
DIRECTION SYMBOL
TYPICAL GRAPHIC SCALE
DETAIL #
PAGE #
DETAIL #
PAGE #
VIEW NORTH ARROW
A8.1
EXTERIOR ELEVATION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
A8.1
BUILDING SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
A8.1
DETAIL SECTION
SYMBOL
DETAIL #
PAGE #
A8.1
WALL GRID
(REPRESENTS
FACE OF EXISTING
WALL)
XX.X
XX.X
ELEVATION
0'-0"
ROOM
NAME
101A
NORTHNORTH
0 4 8 16
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN
VOLUNTARY STANDARD BODIES.
GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS SPECIFY OTHER CODES AND
STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
VA SUSTAINABLE DESIGN MANUAL, AUGUST 2017
VA SITE DEVELOPMENT DESIGN MANUAL, FEBRUARY 2013
VA VHA DIRECTIVE 1061, FEBRUARY 2021
VA FIRE PROTECTION DESIGN MANUAL, 2021
VA PLUMBING DESIGN MANUAL, MAY 2021
VA HVAC DESIGN MANUAL, MARCH 2022
VA PHYSICAL SECURITY AND RESILIENCY DESIGN MANUAL, 2022
VA LIGHTING DESIGN MANUAL, DECEMBER 2022
VA ELECTRICAL DESIGN MANUAL, DECEMBER 2019
VA INTERIOR DESIGN MANUAL, NOVEMBER 2020
VA OFFICE OF INFORMATION & TECHNOLOGY DESIGN GUIDE, FEBRUARY 2019
VA INFRASTRUCTURE STANDARD FOR TELECOMMUNICATIONS SPACES DESIGN GUIDE, AUGUST 2020
• PG 18-13 VA BARRIER FREE DESIGN STANDARD, FEBRUARY 2022
• PG 18-4 VA STANDARD DETAILS AND SPECIFICATIONS
• INTERNATIONAL BUILDING CODE (IBC) 2021 (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES
BELOW).
• INTERNATIONAL MECHANICAL CODE 2021
• INTERNATIONAL PLUMBING CODE 2021
• INTERNATIONAL FUEL GAS CODE 2021
• ADA STANDARDS FOR ACCESSIBLE DESIGN 2010
• NFPA 99, HEALTH CARE FACILITIES CODE, 2021
• NFPA 90A, INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS, 2021
• NFPA 13, INSTALLATION OF SPRINKLER SYSTEMS, 2022
• NFPA 72, NATIONAL FIRE ALARM CODE 2022
• NFPA 101 LIFE SAFETY CODE 2021 (SEE NOTES BELOW)
• NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA 5000 AND NFPA 900
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
• VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• NFPA 70 NATIONAL ELECTRICAL CODE (NEC) 2020
• SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.
• ASME BOILER AND PRESSURE VESSEL CODE
• ASME CODE FOR PRESSURE PIPING
• BUILDING SERVICES PIPING, ASME B31.9
• ANSI/TIA/EIA 568-2019 COMMERCIAL BUILDING CABLING STANDARDS
• ANSI/TIA/EIA 569-C-2015 COMMERCIAL BUILDING STANDARDS FOR TELECOMMUNICATIONS PATHWAYS AND SPACES
• ANSI/TIA-1179-2017, TELECOMMUNICATION SPACES FOR HEALTHCARE FACILITIES
• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS) INCLUDING VA SUPPLEMENT, BARRIER FREE DESIGN
STANDARD (PG-18-13)
• BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318)
• MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE FACTOR DESIGN SPECIFICATIONS FOR STRUCTURAL STEEL
BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
• DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH- RISE RESIDENTIAL BUILDINGS AND NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.
• FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
• THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 01010 OF THE
VA MASTER CONSTRUCTION SPECIFICATION.
• VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1- 2019.
• SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15 – 2019.
• VENTILATION FOR HEALTH CARE FACILITIES – ASHRAE STANDARD 170- 2021
• ENERGY STANDARDS FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS – ASHRAE 90.1 – 2019
• ASHRAE HANDBOOKS, 2017 FUNDAMENTALS, 2019 HVAC APPLICATIONS, 2020 HVAC SYSTEMS AND EQUIPMENT
• INTERNATIONAL STANDARDS FOR HEMATOPOIETIC CELLULAR THERAPY THERAPY PRODUCT COLLECTION, PROCESSING, AND
ADMINISTRATION, EIGHTH EDITION
• ILLUMINATING ENGINEERING SOCIETY (IES) LIGHTING HANDBOOK, 10TH EDITION
• FACILITIES GUIDELINES INSTITUTE: GUIDELINES FOR THE DESIGN AND CONSTRUCTION OF HOSPITALS, 2018
• SMACNA, HVAC DUCT CONSTRUCTION STANDARDS, METAL AND FLEXIBLE
• SMACNA, HVAC AIR DUCT LEAKAGE TEST MANUAL
• BICSI, TELECOMMUNICATIONS DISTRIBUTIONS METHODS MANUAL, 2014
• FEDERAL INFORMATION PROCESSING STANDARDS-FIBS-201-1: PERSONAL IDENTITY VERIFICATION (PIV) OF FEDERAL
EMPLOYEES AND CONTRACTORS
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN. DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING
JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
REMOVE ALL WORK ASSOCIATED WITH REPAINTING OF STEEL HANDRAILS AROUND THE FOUR COURTYARD AREAS ON TOP OF MAIN HOSPITAL ROOF AND THE TWO
COURTYARD AREAS OF THE CLC BUILDING ROOF.
REMOVE THE LIGHTNING PROTECTION REPLACEMENT FROM CONTRACTOR'S SCOPE OF WORK.
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1 /2
:2
:4
P M
C U s e rs
\o m a n ts c h \D o c u m e n ts
\R e v it L o c a l\ A
G I_
-3
-V
A L o m a L in d a R e p la c e
R o o f_ o m a n ts c h
.r v t
G-002
GENERAL INFORMATION
2 3OKM
ROOF REPLACEMENT AND
LIGHTNING PROTECTION
VA LOMA LINDA HEALTHCARE SYSTEM
11201 BENTON ST, LOMA LINDA,
CA 92357 DECEMBER 20, 2023
100% BID DOCUMENTS
605-20-41121-330-Q31
TM
GENERAL SYMBOL LEGEND CODE STANDARDS AND EXECUTIVE ORDERS
DEDUCTIVE ALTERNATES
2 3
1 2
2 4
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1 /2
:2
:4
P M
C U s e rs
\o m a n ts c h \D o c u m e n ts
\R e v it L o c a l\ A
G I_
-3
-V
A L o m a L in d a R e p la c e
R o o f_ o m a n ts c h
.r v t
GC100
GENERAL SITE INFORMATION
3 3OKM
ROOF REPLACEMENT AND
LIGHTNING PROTECTION
VA LOMA LINDA HEALTHCARE SYSTEM
11201 BENTON ST, LOMA LINDA,
CA 92357 DECEMBER 20, 2023
100% BID DOCUMENTS
605-20-41121-330-Q31
TM
N
KEY PLAN
SCALE: NO SCALE
1 POSSIBLE LOCATION OF CRANE FOR LIFTING
SUPPLIES TO THE ROOF, OR REMOVING DEBRIS
FROM ROOF.
2 POSSIBLE LOCATION OF DUMPSTERS AND TRASH
CHUTES, COORDINATE WITH COR PRIOR TO
LOCATING ITEMS.
3 POSSIBLE SUPPLY LAY DOWN AREA FOR
CONTRACTOR.
4 AREAS OF EXISTING BUILDINGS TO BE REROOFED
AS PART OF THIS PROJECT, SEE ROOF
DEMOLITION PLANS AD-101 AND AD-102 FOR
SPECIFIC AREAS OF ROOF WORK.
A. CONTRACTOR TO COORDINATE LOCATION AND
SCHEDULING OF CRANE TO LIFT SUPPLIES ONTO
ROOF WITH COR PRIOR TO CRANE OPERATIONS
STARTING. MINIMUM TWO WEEKS PRIOR TO
CRANE ARRIVAL. PROVIDE CRANE LIFT PLAN TO
THE COR PRIOR TO START OF CONSTRUCTION
FOR REVIEW.
B. CONTRACTOR WILL PERFORM CRANE OPERATION
AT HOSPITAL MINIMAL OPERATIONAL TIMES,
MAINLY WEEKENDS, COORDINATED EXACT
TIMES/DATES AND DURATIONS WITH COR PRIOR
TO COMMENCING CRANE OPERATIONS.
C. CONTRACTOR RESPONSIBLE TO PROTECT ALL
PAVING, CONCRETE, LANDSCAPE, ETC IN AREAS
WHERE CRANE WILL BE LOCATED. INDLUDING
CRANE TRANSIT ON SITE TO AND FROM THOSE
LOCATIONS.
D. CONTRACTOR SHALL REPAIR ALL DAMAGE
CAUSED AS A RESULT OF CONSTRUCTION WORK
ASSOCIATED WITH THIS PROJECT TO THIS SITE ,
LANDSCAPING, BUILDINGS OR ANY OTHER AREA
BACK TO ORIGINAL CONDITION.
E. CONTRACTOR SHALL ENSURE PROPER SAFETY
BARRIERS AND ENCLOSURES ARE PROVIDED AT
ALL ENTRY/EXIT POINTS FROM BUILDING OR
PATHWAYS BELOW WHERE WORK IS BEING
PERFORMED ABOVE. SAFETY BARRIER TO
INCLUDE COVERED WALKWAYS BELOW AREAS
WHERE ROOF WORK IS BEING PERFORMED.
SIGNAGE AND BARRIERS TO RESTRICT
PEDESTRIAN TRAFFIC IN AREAS WHERE WORK IS
BEING PERFORMED AND ANY PROTECTIVE
MEASURES REQUIRED TO PROTECT PATIENTS,
STAFF, VISITOR OR OTHER PERSONNEL FROM
THE ROOF WORK BEING PERFORMED.
F. CONTRACTOR TO SET UP AND MAINTAIN
TEMPORARY GUARDS AT EDGE OF ROOF WHERE
WORK IS BEING PERFORMED AND ALL
PERSONNEL TO WEAR PROPER SAFETY
DEVICES/FALL PROTECTION PER OSHA
STANDARDS.
G. CONTRACTOR SHALL PROVIDE SCAFFOLDING
FOR ROOF ACCESS AS NECESSARY TO PERFORM
WORK. FINAL LOCATION TO BE COORDINATED
WITH COR. IF REQUIRED, ROOF ACCESS IS
AVAILABLE.
H. CONTRACTOR SHALL ENSURE SCAFFOLDING AND
PROTECTIVE MEASURES COMPLY WITH ALL OSHA
REQUIREMENTS. CONTRACTOR SHALL BE
RESPONSIBLE FOR DESIGN AND ENGINEERING OF
SCAFFOLDING AND PROTECTIVE MEASURES.
I. DUMPSTER AND TRASH CHUTE LOCATIONS ARE
TO BE COORDINATED WITH THE COR PRIOR TO
LOCATION ON SITE. SEE SHEET GC101 FOR
SUGGESTED LOCATIONS OF LAY DOWN AREAS.
J. CONTRACTOR SHALL PROTECT THE LANDSCAPE
IRRIGATION SYSTEM IN THE CONSTRUCTION
AREA FROM DAMAGE. CONTRACTOR TO REPAIR
ANY DAMAGE TO IRRIGATION SYSTEM AND
ADJUST ALL HEADS AFFECTED BY
CONSTRUCTION.
K. CONTRACTOR SHALL PREPARE A PLAN SHOWING
LAY DOWN AREA, SECURITY FENCE, DUMPSTER,
LOCATION, SCAFFOLDING AND ACCESS FOR COR
REVIEW AND APPROVAL.
L. CONTRACTOR SHALL ENSURE ALL SCAFFOLDING
IS LOCKED AT ALL TIMES WHEN IT IS NOT IN USE
BY THE CONTRACTOR.
M. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
WORK AT AREAS NOTED AS HAZARDOUS OR
RADIATION HAZARD AREAS. THERE IS A
RADIATION HAZARD FOR WORKERS WORKING ON
TOP OF ALL SEVEN (7) PENTHOUSES LOCATED ON
TOP OF THE MAIN HOSPITAL ROOF. THE
CONTRACTOR SHALL COORDINATE WITH THE
COR AND FACILITY SAFETY PERSON FOR ALL
REQUIREMENTS FOR WORK IN THESE AREAS.
| Sheets |
| G-001 - COVER SHEET |
| G-002 - GENERAL INFORMATION |
| GC100 - GENERAL SITE INFORMATION |
| 2023-12-22T11:04:23-0800 | |
| Digitally verifiable PDF exported from www.docusign.com |