AMENDMENT 5 TO SOLICITATION 36C26026R0076
This is Standard Form 30, an Amendment to Solicitation issued by the NCO 20 Network Contracting Office on June 4, 2026, with an effective date of June 16, 2026. The amendment clarifies requirements for Blast Resistant Door Assemblies under specification section 08 11 13. The contracting officer clarifies that while door assemblies must be constructed to specification, a fully blast-resistant door is not required. Door panels shall be a minimum of 14 gauge and are not required to be explicitly designed for blast. However, door panels must bear against a continuous stop and frame designed and anchored for blast, as specified in subsection 2.1.A.2. Contractors may alternatively provide a fully blast-resistant door that exceeds the specification requirements if they choose to do so.
The proposal submission deadline remains unchanged, with proposals due no later than 1200 PM Pacific Time on June 17, 2026. Offerors/bidders must acknowledge receipt of this amendment prior to the deadline by completing and returning the amendment, acknowledging receipt on each copy of the offer submitted, or by separate letter or electronic communication referencing the solicitation and amendment numbers. Failure to provide timely acknowledgment may result in rejection of the offer. The requisition/purchase requisition number is 653-23-100, and the contract ID code is 36C26026R0076. Stephen Slaby is the Contracting Officer administering this amendment.
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5. PROJECT NUMBER (if applicable)
CODE 7. ADMINISTERED BY
2. AMENDMENT/MODIFICATION NUMBER
CODE
6. ISSUED BY
8. NAME AND ADDRESS OF CONTRACTOR
4. REQUISITION/PURCHASE REQ. NUMBER 3. EFFECTIVE DATE
9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED
PAGE OF PAGES
10A. MODIFICATION OF CONTRACT/ORDER NUMBER
10B. DATED
BPA NO. 1. CONTRACT ID CODE
FACILITY CODE CODE
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
E. IMPORTANT:
is extended,
(a) By completing Items 8 and 15, and returning __________ copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY is not extended.
12. ACCOUNTING AND APPROPRIATION DATA
(REV. 11/2016)
is required to sign this document and return ___________ copies to the issuing office. is not, A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO. IN ITEM 10A.
15C. DATE SIGNED
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER
Contractor
16C. DATE SIGNED
14. DESCRIPTION OF AMENDMENT/MODIFICATION
16B. UNITED STATES OF AMERICA
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER 16A. NAME AND TITLE OF CONTRACTING OFFICER
15B. CONTRACTOR/OFFEROR
STANDARD FORM 30 PREVIOUS EDITION NOT USABLE
Prescribed by GSA - FAR (48 CFR) 53.243
(Type or print) (Type or print)
(Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
(Number, street, county, State and ZIP Code)
(If other than Item 6)
(Specify type of modification and authority)
(such as changes in paying office, appropriation date, etc.)
(If required)
(SEE ITEM 11)
(SEE ITEM 13)
(X)
CHECK
ONE
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
(Signature of person authorized to sign) (Signature of Contracting Officer)
1 1
0005 06-16-2026
653-23-100
NCO 20 Network Contracting Office
ATTN: V4CONT
1601 E. Fourth Plain Blvd Bldg.17, Suite B428 Vancouver WA 98661
NCO 20 Network Contracting Office
ATTN: V4CONT
1601 E. Fourth Plain Blvd Bldg.17, Suite B428 Vancouver WA 98661
To all Offerors/Bidders
36C26026R0076
04-29-2026
X
X X
The purpose of Amendment 5 is to further clarify the requirements for the Blast Resistant Door Assemblies as follows:
The door must be constructed to the specification, but we do not require a fully blast resistent door. As stated in specification section 08 11 13, subparagraph 2.1.A.2.c door panels shall be a minimum of 14 gauge and “are not required to be explicitly designed for blast.” However, as stated in 2.1.A.2.a door panels shall bear against a continuous stop and frame designed and anchored for blast. Please refer to subsection 2.1.A.2 in its totality for all door blast requirements. The contractor may alternatively provide a fully blast resistant door that exceeds spec section 08 11 13 requirements, if they so choose.
The proposal due date and time remains unchanged. Proposals are due no later than 1200 PM Pacific Time on 17 June 2026.
Stephen Slaby Contracting Officer