G6 SARRTP FIRE SYSTEM.pdf

PDF 348 KB Posted

Attached to
Z2DA--Repurpose 5th Floor for SARRTP Federal contract opportunity
Solicitation number
36C25921R0031
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19

About this file

This document includes a federal contract opportunity solicitation and related construction project documents. The Department of Veterans Affairs is soliciting proposals for construction services to repurpose the fifth floor of the Grand Junction VA Medical Center in Colorado for a Substance Abuse Residential Rehabilitation Treatment Program. The project scope involves fire alarm and detection system upgrades throughout the floor. Proposed construction is estimated to cost between $500,000 and $1,000,000. The solicitation will be issued on January 21, 2021, and the opportunity is reserved exclusively for Service-Disabled Veteran-Owned Small Businesses. Submitted proposals must come from firms verified and listed in the Vendor Information Pages database.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--Repurpose 5th Floor for SARRTP, newest first.
File Type Posted
36C25921R0031 0005.docx DOCX document
36C25921R0031 0004.docx DOCX document
03c Combined Specifications-3-17-2021.pdf PDF
36C25921R0031 0003.docx DOCX document
Past Performance Questionnaire.docx DOCX document
G2 SARRTP EXISTING _ ICRA.pdf PDF
G5 SARRTP EQUIPMENT.pdf PDF
010000 General Conditions.pdf PDF
RFI 1.pdf PDF
36C25921R0031 0002.docx DOCX document
Instructions to Offerors - PPT-updated.pdf PDF
G3 SARRTP DEMO.pdf PDF
G8 SARRTP DETAIL.pdf PDF
G4 SARRTP CONSTRUCTION.pdf PDF
G7 SARRTP VIDEO SYSTEM.pdf PDF
G1 SARRTP FUNCTIONAL PLAN.pdf PDF
RFI 3 factor 1.pdf PDF
RFI 2.pdf PDF
2016-09-07 S04 -Site Visit Meeting Doc.pdf PDF
36C25921R0031 0001.docx DOCX document
20210224_575-20-114 SARRTP PreBid GC Site Walk.pdf PDF
36C25921R0031_1.docx DOCX document
03b Background.pdf PDF
03a Combined Drawings.pdf PDF
01b Bid Sheet.xlsx XLSX spreadsheet
03c Combined Specifications.pdf PDF
Show all 26

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N U

R S

E S

T A

T

IO

N

S E

C

LU

S

IO

R O

O M

T O

ILE

T

T O

ILE

T

T O

ILE

T

5431X

T O

ILE

T

5419A

E

LE

C . C

LO

T O

ILE

T

5431A

T O

ILE

T

D A

T A

C

LO

D A

T A

C

LO

T O

ILE

T

LA

U N

D R

Y

C

LO

S E

T 5400A

V E

S T

IB

U

LE

V

E

LE

C . C

LO

S -3

P -2

P -1

167 S F

158 S F

234 S F

321 S F

164 S F

221 S F

174 S F

93 S F

115 S F

182 S F

182 S F

186 S F

39 S F

121 S F

191 S F

51 S F

54 S F

78 S F

89 S F

117 S F

319 S F

123 S F32 S

F

106 S F

109 S F

32 S F

124 S F

158 S F

125 S F

141 S F

143 S F

H A

C

W A

L L

M O

U N

T E

D

LIG

H T

E A

S T

W

IN

G N

O T

P A

R T

O F

T H

IS

C

O N

T R

A C

T

E A

S T

W

IN

G N

O T

P A

R T

O F

T H

IS

C

O N

T R

A C

T

T V

M E

D G

A S

V A

LV

E

S

M E

D G

A S

V A

L V

E S

M E

D G

A S

V A

LV

E

S

IC

E

M A

K E

R

D .E

. C lg

D .E

. C lg

D .E

. C lg

S D

E xistin g S m oke D etector

N ew

S m oke D etector to be w ithin 15' of egress door.

N ew

S m oke D etector to be w ithin 15' of egress door.

N ew

S m oke D etector to be w ithin 30' of new corridor sm oke detectors to east & w est.

F S

F S

F A

F A

E xistin g F ire

A la rm w ith S trob e Light

E xistin g F ire

S trob e Light

E xistin g F ire

S trob e Light

E xistin g F ire

A larm w ith S tro be

Light

E xistin g F ire

A larm w ith S tro be

Light E xistin g F ire A larm w ith S tro be Light

E xistin g F ire

A larm w ith S tro be

Light

L S

56 S F

E xisting

S urve illa nce

C am era

C

E xisting

S urve illa nce

C am era

C

F

IR

E A

LA

R

M S

Y S

T E

M B

ID

IT

E M

S

Provide patient room s w ith new fire alarm speakers (12 each total). Additional sm oke detectors to be addressable as show n on draw ing.

Provide bath room s w ith new fire alarm strobe lights (6 each total).

N ew fire alarm strobe light w ith speaker in room

5424 (1 each total).

N ew corridor fire alarm sm oke detectors (3 each total).

Contractor to provide fire alarm w iring diagram

, program ing and graphic updates for new fire alarm system

FIRE ALARM

SYSTEM

N O

TES;

A

N ew corridor ceiling m ounted sm oke detector sym bol (3 each) = S

D B

N ew patient room w all m ounted fire alarm speaker sym bol= F

S C

N ew bath room w all m ounted fire alarm strobe light sym bol = F

L D

P rovide patient room s w ith new fire alarm speakers (12 each total).

E

P rovide bath room s w ith new fire alarm strobe lights (6 each total).

F

N ew fire alarm strobe light w ith speaker in room

5424 (1 each total), sym bol = LS

G

N ew fire alarm equipm ent to m atch the existing 5th floor; corridor photo sensor sm oke detectors, fire alarm speakers and fire alarm strobe lights.

H

Install new fire sm oke detectors in ceiling tiles used by existing equipm ent so ceiling access is not reduced by new equipm ent.

I.

N ew sm oke detectors cannot be w ithin 3'-0" from the outside edge of any hvac venting.

J.

N ew corridor fire alarm sm oke detectors (3 ea total) m ust w ithin 15'-0" from the egress doors and a m axim um distance of 30'-0" apart.

K

F ire alarm speakers & fire alarm strobe lights to be m ounted 80" a.f.f. or 6" from ceiling, w hich ever is low er.

L.

C ontractor to provide fire alarm w iring diagram

, program ing and graphic updates for new fire alarm equipm ent.

F S

F S

F S

F L

F S

S D

F A

F L

F S

S D

F S

F A

S D

F S

F S

E xistin g S m oke D etector

S D

F A

F L

F L

F L

F L

F S

F S

E xistin g S m oke D etector

S D

E xistin g S m oke D etector

S D

E xistin g F ire

A larm w ith S tro be

Light

F A

F A

E xistin g S m oke D etector

S D

E xistin g S m oke D etector

S D

E xistin g S m oke D etector

S D

E xistin g S m oke D etector

S D

F A

E xistin g F ire

S trob e Light F

A

E xistin g F ire

S trob e Light

F A

E xistin g F ire

S trob e Light

F S

E xistin g F ire

S trob e Light in existing restroom

F S

F ire A larm S ystem M odifications G

575-20-114 R epurpose 5th F loor for S

A R

R T

P C onstruction D ocum ents

10/10/2020

R E

V

IS

IO

N

S

6869707172

P H

A S

E 1 - S

O U

T H

W

IN

G

P H

A S

E 2 - W

E S

T W

IN

G

P H

A S

E 1 - S

O U

T H

W

IN

G

P H

A S

E 2 - W

E S

T W

IN

G

S C

A

LE

0' 5'

10'

File details come from the government source that posted it. Updated .