G3 SARRTP DEMO.pdf
PDF 340 KB Posted
- Attached to
- Z2DA--Repurpose 5th Floor for SARRTP Federal contract opportunity
- Solicitation number
- 36C25921R0031
About this file
This document includes a floor plan diagram and demolition instructions for repurposing the fifth floor of the Grand Junction VA Medical Center in Grand Junction, Colorado. Products and services required include construction services to complete the repurposing project, which involves demolishing and removing various fixtures from patient rooms, common areas, and medical gas systems. Key tasks involve relocating sinks, medical equipment, doors, walls and other infrastructure to configure the floor for its new purpose. The related federal contract opportunity is a pre-solicitation notice for solicitation number 36C25921R0031 for the fifth floor repurposing project. The project magnitude is between $500,000 to $1,000,000 and is fully set aside for service-disabled veteran-owned small businesses. The Department of Veterans Affairs is the contracting agency.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25921R0031 0005.docx | DOCX document | |
| 36C25921R0031 0004.docx | DOCX document | |
| 03c Combined Specifications-3-17-2021.pdf | ||
| 36C25921R0031 0003.docx | DOCX document | |
| Instructions to Offerors - PPT-updated.pdf | ||
| G6 SARRTP FIRE SYSTEM.pdf | ||
| G8 SARRTP DETAIL.pdf | ||
| G4 SARRTP CONSTRUCTION.pdf | ||
| G7 SARRTP VIDEO SYSTEM.pdf | ||
| Past Performance Questionnaire.docx | DOCX document | |
| G2 SARRTP EXISTING _ ICRA.pdf | ||
| G5 SARRTP EQUIPMENT.pdf | ||
| 010000 General Conditions.pdf | ||
| RFI 1.pdf | ||
| 36C25921R0031 0002.docx | DOCX document | |
| G1 SARRTP FUNCTIONAL PLAN.pdf | ||
| RFI 3 factor 1.pdf | ||
| RFI 2.pdf | ||
| 2016-09-07 S04 -Site Visit Meeting Doc.pdf | ||
| 36C25921R0031 0001.docx | DOCX document | |
| 20210224_575-20-114 SARRTP PreBid GC Site Walk.pdf | ||
| 36C25921R0031_1.docx | DOCX document | |
| 03b Background.pdf | ||
| 03a Combined Drawings.pdf | ||
| 01b Bid Sheet.xlsx | XLSX spreadsheet | |
| 03c Combined Specifications.pdf |
Show all 26
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N U
R S
E S
T A
T
IO
N
S E
C
LU
S
IO
R O
O M
T O
ILE
T
T O
ILE
T
T O
ILE
T
5431X
T O
ILE
T
5419A
E
LE
C . C
LO
T O
ILE
T
5431A
T O
ILE
T
T O
ILE
T
D A
T A
C
LO
D A
T A
C
LO
T O
ILE
T
LA
U N
D R
Y
C
LO
S E
T 5400A
V E
S T
IB
U
LE
V
T O
ILE
T
E
LE
C . C
LO
S -3
P -2
P -1
H A
C
E A
S T
W
IN
G N
O T
P A
R T
O F
T H
IS
C
O N
T R
A C
T
E A
S T
W
IN
G N
O T
P A
R T
O F
T H
IS
C
O N
T R
A C
T
M E
D G
A S
V A
LV
E
S
M E
D G
A S
V A
LV
E
S
M E
D G
A S
V A
LV
E
S
IC
E
M A
K E
R
EXISTNG
COUNTER TOP
W A
L
L LIG
H T
54 S F
R E
C E
P T
IO
N
IT
C
LO
S
E T
D rinking
F oun tain
M. GAS HEADWALL
28" x 8"
M E
D G
A S
H E
A D
W A
LL
6" x 8" M
E D
G A
S H
E A
D W
A
LL
6" x 8"
M. GAS HEADWALL
28" x 8"
M. GAS HEADWALL
28" x 8"
M. GAS HEADWALL
28" x 8"
MED GAS HEADWALL
36" x 8"
MED GAS HEADWALL
36" x 8"
M E
D G
A S
H E
A D
W A
LL
0" x 8"
MED GAS HEADWALL
40" x 8"
MED GAS HEADWALL
40" x 8"
M. GAS HEADWALL
28" x 8"
M. GAS HEADWALL
28" x 8"
M. GAS HEADWALL
28" x 8"
MEDICAL GAS HEADWALL 100" x 12"
M E
D G
A S
H E
A D
W A
LL
6" x 8"
M. GAS HEADWALL
28" x 8"
M E
D G
A S
H E
A D
W A
LL
6" x 8" M
E D
G A
S H
E A
D W
A
LL
6" x 8"
M. GAS HEADWALL
28" x 8"
M. GAS HEADWALL
28" x 8"
M. GAS HEADWALL
28" x 8"
MED GAS HEADWALL
36" x 8"
MED GAS HEADWALL
36" x 8"
M E
D G
A S
H E
A D
W A
LL
0" x 8"
MED GAS HEADWALL
40" x 8"
MED GAS HEADWALL
40" x 8"
M. GAS HEADWALL
28" x 8"
M. GAS HEADWALL
28" x 8"
M. GAS HEADWALL
28" x 8"
MEDICAL GAS HEADWALL 100" x 12"
M E
D G
A S
H E
A D
W A
LL
6" x 8"
M E
D G
A S
H E
A D
W A
LL
6" x 8"
MED GAS HEADWALL
36" x 8"
MED GAS HEADWALL
36" x 8"
E xistin g co ntrolled a cce ss doo r w ith a la rm
R E
L O
C A
T E
R M
5416 S
IN
K E
A S
T A
N D
A T
T A
C H
T O
N E
W S
T E
E L
F R
A M
E D
W A
LL.
R E
L O
C A
T E
R M
5415 S
IN
K W
E S
T A
N D
A T
T A
C H
T O
N E
W S
T E
E L
F R
A M
E D
W A
LL.
R
E M
O V
E R
M
D
IS
P
O S
A L
S
IN
K
P R
O V
ID
E
P
LU
M B
IN
G
A C
C E
S S
P A
N E
L.
M O
V E
R M
0 D O
O R
S O
U T
H
A D
D N
E W
S T
E E
L F
R A
M E
D W
A
LL
A N
D C
U T
D O
W N
W A
LL LIG
H
T
R E
L O
C A
T E
R O
O M
1 S
IN
K W
E S
T
" F
R O
M E
N T
R Y
D O
O R
REMOVE PATIENT LIFT
& CEILING TRACK
REMOVE PATIENT LIFT
& CEILING TRACK
1 Rem ove Privacy Curtain And Ceiling Track; Return Equipm ent To VA.
Rem ove Patient Lift & Associated Ceiling Supports, Provide &
Label O utlet Box For Term inated Electric. Return Equipm ent To VA.
Rem ove Patient Room Ceiling Cam eras. Provide & Label O utlet Box At Term inated W ire. Return Equipm ent To VA.
Repair Drop Ceiling M etal & Replace 2' X 4' Ceiling Tiles if dam aged during dem olition.
Rem ove W all M ounted TV's, Provide O utlet Box &
Label Term inated Cable. Leave 110 O utlet, Return TV & Equipm ent To VA.
Rem ove W all, Rem ove D oor &
Fram
e. Rem ove W all (8.5' x 65'). Resize hallw ay 5200 w all m ounted light for new door openings to room s 5419A &
5420 and entry from elevator lobby.
Rem ove/D em o G lass Storefront W indow
D oor.
Relocate N urse Call equipm ent, rem ove patient room bathroom pull cords and cover nurse call outlets w ith blank plates for possible future use. Coordinate relocation of N urse Call w ith VA Engineering and Sterling Com m unications 303-384-3404.
Rem ove patient room 5001 sink, counter top and w ardrobe cabinet. Provide m etal access panel for abandoned sink.
Rem ove existing nurses station, cabinets and counter tops. Return all equipm ent to VA.
Rem ove disposal sink near exterior w all and provide m etal access panel for abandoned plum bing.
R em ove all existing patient room chair w all hooks, sharps containers, glove dispensers and alcohol hand w ash stations. Return all the rem oved item s and equipm ent to the G
J V A
Engineering .
Rem ove / Seal 2' x 2' O pening In Concrete Floor O f Electrical Room 5423.
Rem ove m etal shelving
51 Rem ove / abate & dispose of any hazardous m aterial see the attached bid package 2018 report - the G
JVA m ust give direction.
Infection control m easures - SEE PLAN
SH
EET G
2.
Construction trash - Roll O ff Bin furnished by contractor, coordinate bin location w ith G
JVA.
R E
M O
V E
6" D
O O
R A
D D
" D O
O R
14 E xisting V ideo S ystem 3
W A
L L
M O
U N
T E
D
LIG
H T
W A
L L
M O
U N
T E
D
LIG
H T
W A
L L
M O
U N
T E
D
LIG
H T
W A
L L
M O
U N
T E
D
LIG
H T
W A
L L
M O
U N
T E
D
LIG
H T
WALL MOUNTED LIGHTWALL MOUNTED LIGHT
WALL LIGHT
D em olition G
575-20-114 R epurpose 5th F loor for S
A R
R T
P C onstruction D ocum ents
10/10/2020
R E
V
IS
IO
N
S 11051 11121314 23456789
P H
A S
E 1 - S
O U
T H
W
IN
G
P H
A S
E 2 - W
E S
T W
IN
G
P H
A S
E 1 - S
O U
T H
W
IN
G
P H
A S
E 2 - W
E S
T W
IN
G
E xisting N urse
C all E quipm ent
S C
A
LE
0' 5'
10'