G4 SARRTP CONSTRUCTION.pdf

PDF 322 KB Posted

Attached to
Z2DA--Repurpose 5th Floor for SARRTP Federal contract opportunity
Solicitation number
36C25921R0031
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19

About this file

This document contains construction documents and specifications for the repurposing of the fifth floor at the Grand Junction VA Medical Center in Grand Junction, Colorado. The project includes renovations to patient rooms, bathrooms, offices, and common areas to accommodate a Substance Abuse Residential Rehabilitation Treatment Program. The construction scope of work involves installing new walls, doors, flooring, plumbing fixtures, medical gas connections, and electrical upgrades. All work must be completed in accordance with the specifications and drawings provided.

This related federal contract opportunity is a presolicitation notice for construction services for the above-described repurposing project. The estimated value is between $500,000 and $1,000,000. The solicitation will be issued on or around January 21, 2021. This procurement is set aside entirely for service-disabled veteran-owned small businesses. Offerors must be verified as such by the Department of Veterans Affairs Center for Verification and Evaluation prior to award. The contracting agency is the Veterans Health Administration within the Veterans Integrated Service Network 19.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--Repurpose 5th Floor for SARRTP, newest first.
File Type Posted
36C25921R0031 0005.docx DOCX document
36C25921R0031 0004.docx DOCX document
03c Combined Specifications-3-17-2021.pdf PDF
36C25921R0031 0003.docx DOCX document
Past Performance Questionnaire.docx DOCX document
G2 SARRTP EXISTING _ ICRA.pdf PDF
G5 SARRTP EQUIPMENT.pdf PDF
010000 General Conditions.pdf PDF
RFI 1.pdf PDF
36C25921R0031 0002.docx DOCX document
G1 SARRTP FUNCTIONAL PLAN.pdf PDF
RFI 3 factor 1.pdf PDF
Instructions to Offerors - PPT-updated.pdf PDF
G3 SARRTP DEMO.pdf PDF
G6 SARRTP FIRE SYSTEM.pdf PDF
G8 SARRTP DETAIL.pdf PDF
G7 SARRTP VIDEO SYSTEM.pdf PDF
RFI 2.pdf PDF
2016-09-07 S04 -Site Visit Meeting Doc.pdf PDF
36C25921R0031 0001.docx DOCX document
20210224_575-20-114 SARRTP PreBid GC Site Walk.pdf PDF
03b Background.pdf PDF
03a Combined Drawings.pdf PDF
01b Bid Sheet.xlsx XLSX spreadsheet
36C25921R0031_1.docx DOCX document
03c Combined Specifications.pdf PDF
Show all 26

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N U

R S

E S

T A

T

IO

N

S E

C

LU

S

IO

R O

O M

T O

ILE

T

T O

ILE

T

5431X

T O

ILE

T

5419A E

LE

C

C

LO

T O

ILE

T

5431A

T O

ILE

T

D A

T A

C

LO

D A

T A

C

LO

T O

ILE

T

C

LO

S E

T 5400A

C

LO

5P

V E

S T

IB

U

LE

V

T O

ILE

T

E

LE

C . C

LO

T O

ILE

T

T

O

ILE

T

S -3

P -2

P -1

D inning / M ulti P urpose R oom

E duc / G roup R m

K itchenette

P atient R oom (2)

P atient R oom (2)

R ecreation R oom

P atient R oom (2)

P atient R oom (2)

P atient R oom (2)

P atient R oom (2)

P atient R oom (2)

P atient R oom (2)

E : D irty U tility

(P odiatry)

N urses

W orkstations (4)

O ffice, C hief (2)

T eam

W ork R oom (4)

C onsult

R oom

C onsult

R oom

C onsult

R oom

C onsult

R oom

E M

S C loset

35 S F

G roup Living R oom

T O

ILE

T

5431X56 S F

5413 M ulti Liv R m w

/B ath

E A

S T

W

IN

G N

O T

P A

R T

O F

T H

IS

C

O N

T R

A C

T

N O

T E

; 5P E

A S

T W

IN

G

S M

O K

E P

A R

T

IT

IO

N

W A

L L

D

O N

O T

P E

N E

T R

A T

E

M E

D G

A S

V A

LV

E

S

W A

L

L LIG

H T

Laundry

M E

D G

A S

V A

LV

E

S

M E

D G

A S

V A

LV

E

S

I.T

C

LO

S E

TT

H

E R

A P

Y

P atient R oom (2)

D rinking

F oun tain

D oor m oved east R oom 5420.

S ink m oved w est.

S A

R R

T P

C

LE

A N

C

O V

ID

C

LE

A

N S

T O

R A

G E

T O

ILE

T

5431A 35 S

F

F rig

M icrow ave

Ice M aker

D rinking W ater

93 S F

DIRTY UTILITY,

WASHER & DRYER

D ryer

W asher

54 S F

SMART BOARD

5P

S A

R R

T P

C

LE

A N

LIN

E

N S

T O

R A

G E

Ice M aker

D rinking W ater

M. GAS HEADWALL

28" x 8"

M E

D G

A S

H E

A D

W A

LL

6" x 8" M

E D

G A

S H

E A

D W

A

LL

6" x 8"

M. GAS HEADWALL

28" x 8"

M. GAS HEADWALL

28" x 8"

M. GAS HEADWALL

28" x 8"

MED GAS HEADWALL

36" x 8"

MED GAS HEADWALL

36" x 8"

M E

D G

A S

H E

A D

W A

LL

0" x 8"

MED GAS HEADWALL

40" x 8"

MED GAS HEADWALL

40" x 8"

M. GAS HEADWALL

28" x 8"

M. GAS HEADWALL

28" x 8"

M. GAS HEADWALL

28" x 8"

MEDICAL GAS HEADWALL 100" x 12"

M E

D G

A S

H E

A D

W A

LL

6" x 8"

M E

D G

A S

H E

A D

W A

LL

6" x 8"

M. GAS HEADWALL

28" x 8"

M E

D G

A S

H E

A D

W A

LL

6" x 8" M

E D

G A

S H

E A

D W

A

LL

6" x 8"

M. GAS HEADWALL

28" x 8"

M. GAS HEADWALL

28" x 8"

M. GAS HEADWALL

28" x 8"

MED GAS HEADWALL

36" x 8"

MED GAS HEADWALL

36" x 8"

M E

D G

A S

H E

A D

W A

LL

0" x 8"

MED GAS HEADWALL

40" x 8"

MED GAS HEADWALL

40" x 8"

M. GAS HEADWALL

28" x 8"

M. GAS HEADWALL

28" x 8"

M. GAS HEADWALL

28" x 8"

MEDICAL GAS HEADWALL 100" x 12"

M E

D G

A S

H E

A D

W A

LL

6" x 8"

M E

D G

A S

H E

A D

W A

LL

6" x 8"

MED GAS HEADWALL

36" x 8"

MED GAS HEADWALL

36" x 8"

N E

W 36" B

A T

H D

O O

R

N ew Steel Fram ed W alls 2 X 6 (From

Finished Floor To Concrete Structural Deck Above).

N ew for Patient room to secure/cover the m edical gas headw all for future use; install .080 gauge m etal panel w ith STD W hite painted finish (SEE DETAIL SHEET G 8).

N ew for Patient room to secure/cover the m edical gas headw all for future use; install 2x4 m etal fram ed w all w ith 58 " dryw all, w all finish to m atch existing dryw all, paint & base trim

N ew Controlled Access D oor 48" W d X 84" w ith Lam inated G lass View Panel include; Rem ote Control From Reception 5005 &

Card Reader access (SEE D

ETAIL SHEET G

8).

N ew 24" x 24" x 12 " Lam inated G lass View

Panel w ith keypad locks (SEE D

ETAIL SH

EET G

8).

N ew D oor 48" W d X 8G

8).4" H t, 5" x 30" x 1/2" Lam inated G lass View

Panel. To Include; keyed lock and overhead concealed door closer w ith door hold open (SEE DETAIL SHEET G

8).

N ew Patient Room

Door(s) 48" W d X 84" H

t. Include; privacy lock and overhead concealed door closer w ith door hold open.

N ew Bath Room

D oor(s) 36" W d X 84" Ht. To Include; privacy lock and overhead concealed door closer w ith door hold open.

N ew keypad lock for new storage room 5419.

N ew D oor Hardw are, Lever W ith Privacy Lock To M atch Existing Patient Bathroom s, Brush N ickel Finish. Privacy Lever & door closer.

N ew door handle keypad and card control access for I.T. Closet(s), brush nickel finish.

N ew Stand Alone Panic Alarm w ith keypad w ith card reader access.

N ew Surface M ounted D oor Closers &

Door Stop To M atch Existing Patient Room s, Clear Anodized Finish.

N ew w all m ounted stainless steel sink w ith m irror near door 5001. Provide m etal access panel for abandoned sink.

N ew location / relocate w all m ounted sinks to new steel fram ed w all betw een room s 5415 & 5416.

N ew w all m ounted porcelain sink w ith stainless steel fram e m irror to bathroom (s).

N ew flooring for entire room

5410 - M

ATCH

EXISTIN

G

PATIEN

T RO

O M

FLO

O

RIN

G

N ew ice m aker w ith drinking w ater, include plum bing for fresh w ater line and drain piping.

N ew

(1) Sink, SS, single bow l, (1)24" sink base cab w ith (2)doors, (1)36" base w ith (3)draw ers &

(1)60" solid surface countertop w ith 4" backsplash.

N ew

(2) Bathroom

Sinks, SS, single bow l, (2) 30" sink base cab w ith (2)doors, &

(1) 60" solid surface countertop w ith 4" backsplash.

N ew Sink, SS, single bow l, (1)30" sink base cab w ith (2) doors, (1) 18" base cabinet, (2) 36" base cabinets and 12 LF of solid surface counter top(s).

N ew Show er Insert W ith Fixtures exhaust fan w ith light connected to existing duct w ork. Resilient Flooring To M atch Existing Room s.

N ew W asher / D ryer Hookup Plg, Elec W ith Code Com pliant dryer venting thru south exterior w all.

N ew interior w indow in hallw ay w all 36" x 24" x 1/2" lam inated glass, sill to be 54" above the finished floor.

N ew 220v O utlet For Clothes Dryer.

N ew W asher hot/cold w ater hookup and drain.

N ew

LED

Ceiling Light Fixture Panel (2' X 4')

N ew dryw all Repairs For D em o And W ork Adjacent To Any N ew Construction.

N ew Floor Replace &

Repair As N eeded For N ew Construction. N ote all of 5410 needs flooring.

N ew O utlets For TV (84" A.F.F.), w all backing & adustable TV bracket.

N ew 120V Electrical O utlet - electrical panel located in Room #5423.

N ew

IT D

ata O utlet - data closet located in Room

#5409.

N ew Paint for W alls And W all Rails.

N ew Signage For Room s (20 Room Signs &

4 Directional Signs)

P atient R oom (2)

N E

W 48" D

O O

R

N ew

T V

O utlets 84" A

.F .F

N ew

T V

O utlets 84" A

.F .F

15 15

202020

W A

L L

M O

U N

T E

D

LIG

H T

W A

L

L LIG

H T

W A

L L

M O

U N

T E

D

LIG

H T

W A

L L

M O

U N

T E

D

LIG

H T

WALL MOUNTED LIGHTWALL LIGHT

WALL LIGHT

W A

L L

M O

U N

T E

D

LIG

H T

W A

L L

M O

U N

T E

D

LIG

H T

WALL LIGHT

M E

D . E

X A

M

R N

R O

O M

M E

C H

R O

O M

C

O V

ID

S

T O

R A

G E

N E

W O

U T

LE

T

O R

S W

IT

C

H . N

O T

E P

R O

V

ID

E

(1) N

E W

O U

T

LE

T A

T A

LL C

O

V E

R E

D H

E A

D W

A

LLS

O R

P R

O V

ID

E

A C

C E

S S

T O

A T

LE

A

S T

(1)E X

IS

T

IN

G

H E

A D

W A

LLL

O

U T

LE

T

C O

V E

R E

D B

Y N

E W

C O

N S

T R

U C

T

IO

N

M O

V E

E X

IS

T

IN

G

O U

T

LE

T O

R S

W

IT

C H

C onstruction

G

575-20-114 R epurpose 5th F loor for S A

R R

T P

C onstruction

D ocum ents 10/10/2020

R E

V

IS

IO

N

S

1520 161718192126 222324253944 4041424345464748 2732 282930313338 34353637

N ew T

V

O utlets 84"

A .F

.F

G roup T herapy R oom

P H

A S

E 1 - S

O U

T H

W

IN

G

P H

A S

E 2 - W

E S

T W

IN

G

P H

A S

E 1 - S

O U

T H

W

IN

G

P H

A S

E 2 - W

E S

T W

IN

G

Final Construction Clean for scope above - ALL RO

O M

S &

HALLW

AYS.

Buff &

Final Clean all floors for scope above - ALL RO O

M S &

H

ALLW

AYS.

S C

A

LE

0' 5'

10'

File details come from the government source that posted it. Updated .