18.1019.05 - Addendum 5 Dwgs - Pages 8-14.pdf

PDF 4 MB Posted

Attached to
Z2DA--Construct and Renovate Med/Surg Beds for Patient Privacy, B1 and B1C P/N:589-701
Solicitation number
36C25520R0115
Issued by

About this file

This is a pre-solicitation notice for a construction project at the Robert J. Dole VA Medical Center in Wichita, Kansas. The project involves vertically expanding an existing building by two stories and renovating patient rooms on the third floor of another building. The general scope of work includes general construction, demolition, new interior and exterior finishes, mechanical, electrical and plumbing systems, medical gas installation, casework and integration with existing building systems. The estimated cost range is $5-10 million. The NAICS code is 236220 and it is set aside for SDVOSBs. The period of performance is 730 calendar days from notice to proceed. The solicitation package will be available on or about October 20, 2020 with proposals due approximately 30 days later. An organized site visit will be scheduled. Interested offerors should monitor the Beta SAM website for any amendments and direct all questions to the point of contact listed by the deadline specified.

View the file

Other files

File Type Posted
281300 - Physical Access Control System.pdf PDF
18.1019.05 - Addendum 5 Revised AE601.pdf PDF
589-701 PRE BID SIGN IN SHEET.pdf PDF
36C25520R0115 0005.docx DOCX document
000110 Table of Contents revised for A0005.pdf PDF
022113 - Site Surveys.pdf PDF
As builts bldg 19 to bldg 2 connecting cor dwgs.pdf PDF
18.1019.05 Addendum 5 Dwgs pages 1-7.pdf PDF
P09 589-701 Revised Drawings Pg 81-90.pdf PDF
36C25520R0115 0004.docx DOCX document
230923.pdf PDF
P09 589-701 Revised Drawings Pg 1-10.pdf PDF
P09 589-701 Revised Drawings Pg 11-20.pdf PDF
P09 589-701 Revised Drawings Pg 41-50.pdf PDF
P09 589-701 Revised Drawings Pg 71-80.pdf PDF
P09 589-701 Revised Drawings Pg 91-100.pdf PDF
226300.pdf PDF
000110 Table of Contents.pdf PDF
P09 589-701 Revised Drawings Pg 31-40.pdf PDF
P09 589-701 Revised Drawings Pg 61-70.pdf PDF
P09 589-701 Revised Drawings Pg 101-117.pdf PDF
P09 589-701 Revised Drawings Pg 51-60.pdf PDF
P09 589-701 Revised Drawings Pg 21-30.pdf PDF
18.1019.05 - 2020.11.16 - List of Changes.docx DOCX document
226200.pdf PDF
36C25520R0115 0003.docx DOCX document
36C25520R0115 0002.docx DOCX document
RFI received 11-2-2020.docx DOCX document
S02 36C25520R0115_2.docx DOCX document
36C25520R0115 0001.docx DOCX document
P09 589-701 Drawings Pg 41-50.pdf PDF
P09 589-701 Drawings Pg 11-20.pdf PDF
P09 589-701 Drawings Pg 21-30.pdf PDF
P09 589-701 Drawings Pg 31-40.pdf PDF
P09 589-701 Drawings Pg 1-10.pdf PDF
P09 589-701 Drawings Pg 91-100.pdf PDF
P09 589-701 Drawings Pg 51-60.pdf PDF
P09 589-701 Drawings Pg 101-116.pdf PDF
P09 589-701 Drawings Pg 61-70.pdf PDF
P09 Bid Docs - Specs Vol 2.pdf PDF
P09 589-701 Drawings Pg 81-90.pdf PDF
P09 SOW 589-701rev_01.pdf PDF
P09 Bid Docs - Specs Vol 1.pdf PDF
36C25520R0115_2.docx DOCX document
P09 589-701 Drawings Pg 71-80.pdf PDF
Show all 45

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P-703

P-413

P-530

P-530

P-413

P-703

P-413

P-703

P-530

P-413

P-530

P-402

P-530

P-703

P-413

P-530

P-413

P-703

P-530

P-530

P-413

P-703

P-703

P-413

P-703

P-530

P-413

P-530

P-703

P-413

P-413

P-703

P-530

IN ACCORDANCE TO THE VA STANDARDS, CHAPTER 4 "WATER

SUPPLY AND DISTRIBUTION", HOT WATER SUPPLY TO BE AS SHORT

AS POSSIBLE TO THE PLUMBING FIXTURE. FROM THE RECIRCULATION

LOOP TO FIXTURE TO HAVE A MAXIMUM WATER VOLUME OF 24 OZ.

FOR SHOWERS, LAVS AND SINKS.

1/2"

3/4"

3/4"

3/4"

3/4"

3/ 4"

3/ 4"

3/ 4"

3/ 4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/ 4"

1"

1"

1"1"

1"

1"

1"

1 1/4"

1 1/4"

1 1/4"

1 1/4"

1/

4"

1/

4"

1/

4"

1/

4"

1 1/4"

1 1/4"

1/

4"

1/

4"

1 1/2"

1 1/2"

1/

2"

1/

2"

1 1/2"

1 1/2"1 1/2"

1 1/2"1 1/2"

1/

2"

1/

2"

1 1/2"

1 1/2"

1 1/2"

1 1/2"

NC

NC

NC

NC

NC

NC

1/

2"

1/

2"

1 1/2"

1/

2" 1 1/

2"

NC

NC

NC

NC

NC

NC

NC

1/ 2"

E (H

W R

2" E

(H W

1 1/2"

1 1/2"

1/

2"

1 1/2" 1 1/2"

1 1/2"

1/

2"

1 1/2"

1 1/2"

1/

2"

1/

2"

1 1/2"

1 1/2"

1 1/2"

1/

2"

1/

2"

1 1/2"

1 1/2"

1/

2"

1/

2"

1 1/2"

1/

2"

1/

2"

1 1/2"

1 1/2"

1 1/2"

1 1/2"

1 1/2"

1 1/2"

1/

2"

1/

2"

1 1/2"

1 1/2"

1 1/2"

1 1/2"

1 1/2"

1 1/2"

1 1/2"

1 1/2"

1/

2"

1 1/2"

1 1/2"

1/

2"

1/

2"

1 1/2" 1 1/2"

1/

2"

1/

2"

1/

2"

1 1/2"

1 1/2"

1/

2"

1/

2"

1/

2"

1 1/2"

1/

2"

1/

2"

1 1/2"

1/

2"

1/

2"

1 1/2"

1 1/2"

1 1/2"

1 1/2"

1/

2"

1/

2"

1/

2"

1/

2"

1 1/2"

1 1/2"

1/

2"

1/

2"

1 1/2"

P-530

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

CMTA CONSULTING ENGINEERS, INC

10411 MEETING STREET

PROSPECT, KY 40059

FULLY SPRINKLERED

C U s e rs

\c h a d \D o c u m e n ts

\V K

M R

M E

C H

R c h a d c m ta e g rs

.c o m

.r v t

/2 /2

:5

:3

P M

PL302

DOMESTIC HOT WATER RISER

DIAGRAM - RENOVATED AREAGUIDON DESIGN INC.

1221 N PENNSYLVANIA STREET

INDIANAPOLIS, IN 46202

(502)326-3085(502)326-3085

VA WICHITA - MED/SURG BEDS

FOR PATIENT PRIVACY

WICHITA, KANSAS

589-701

1 & 1C

05/22/2020

BID DOCUMENTS

Revisions: Date:

Addendum #5 11/24/2020

3'' V.T.R.

CO

P-103

P-402

FD-C

FD-C

P-809P-104

CO

P-530

P-530

P-530

P-809

P-809

FD-C

FD-C

P-413

P-413

CO

P-104

P-530

FD-C

FD-C

CO

P-413

P-103

P-104

P-413

P-104

FD-C

FD-C

P-809

FLOOR

SUMP

P-413

P-505

P-530

CO

P-104

FD-C

FD-C

P-413

P-530

P-809

P-809

P-530

P-530

P-530

P-402

FD-C

FD-C

P-413

P-104

P-809

P-530

CO

CO P-104

P-809

FD-C

FD-C

P-413

P-413

FD-C

FD-C

P-104

P-530

P-530

FD-C

FD-C

FD-C

FD-C

P-413

P-809

P-104

P-104

CO

P-809

P-530

3'' E(V.T.R.)

3'' E(V.T.R.)

3'' E(V.T.R.)

1/

2"

4"

3"

4" 2"

4"

4"

3"

2"

2"

1/ 2"

3"

3"

4"

2"

2"

2" 3"

1/

2"

1/ 2"

4" 3"

3"

4"

3"

3"

4"

4"

3"

2"

1/

2"

1/

2"

1/

2"

2"

3"

1/

2"

2"

3" 3"

2"

2"

2"

3"

4"

2"

2"

1/

2"

3"

2"

3"

3"

3"

3"

1/

2"

3"

1/ 2"2"

4"

4"

2"

4"

2"

2"

2"

4"

2"

1/

2"

3"

3" 1 1/2"

1/

2"

3"

3"

2"

2"

3"

3"

3"

2"

2"

4"

2"

4"

2"

2"

2"

1/ 2"

3"

2"

1/

2"

1/

2"

2"

3"

3"

3"

4"

4"

4"

2"

3"

4"

3" 3"

2"1 1/2"

1/

2"

2"

3"

3"

2"

1 1/2"

3"

3"

2"

1/

2"

3"

1/

2"

1 1/2"

1/

2"

2"

2"

2"

1/

2"

1/ 2"

2"

1/

2"

1/

2"

2"

2"

3"

2"

1/

2"

3"

2"

4"

4"

3"

3"

3"

1/

2"

2" 4"

4"

3"

2"

2" 2"

1/

2"

3"

2"

1/

2"

2"

1/

2" 1 1/

2" 2"

4"

2"

1/

2"

2"

3"

1/

2"

4"

2"

2"

2"

1/

2"

3"

1/

2"

1/ 2"

1/

2"

1/

2"

2"2"

4"

4"

2"

2"

2"

2"

4"

4"

2"

2"

3"

3"

2"

1/

2"

2"

2"

1/

2"

CO

1/

2" V

2" SAN

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

CMTA CONSULTING ENGINEERS, INC

10411 MEETING STREET

PROSPECT, KY 40059

FULLY SPRINKLERED

C U s e rs

\c h a d \D o c u m e n ts

\V K

M R

M E

C H

R c h a d c m ta e g rs

.c o m

.r v t

/2 /2

:5

:4

P M

PL306

SANITARY WASTE AND VENT

RISER DIAGRAM - RENOVATION

AREA

GUIDON DESIGN INC.

1221 N PENNSYLVANIA STREET

INDIANAPOLIS, IN 46202

(502)326-3085(502)326-3085

VA WICHITA - MED/SURG BEDS

FOR PATIENT PRIVACY

WICHITA, KANSAS

589-701

1 & 1C

05/22/2020

BID DOCUMENTS

4' 8' 32'16'0

1/8" = 1'-0"

24'2'

SCALE:

SANITARY WASTE AND VENT RISER DIAGRAM

- RENOVATION AREA

Revisions: Date:

Addendum #5 11/24/2020

UP

UP

DN

DN

DN

DN

0.8 1.5 2.8 4.6

MM

K.2

J.3J.3

H.9H.9

F.8

F.8

6.9

6.9

6.1

6.1

E E

D D

C C

B B

A A

F F

G G

I I

HH

F.1 F.1

JJ

KK

LL

6 754

1 4.8

B.4 B.4

ICU NURSE MGR (OFA09)

C212

TOILET/SHOWER (TNPG1)

C215A

NOCTURNIST (OFA09)

C215

CHAPEL (RAS01)

C220

MED TEAM 2 (CFR02)

C204

STORAGE (SRSE1)

C201

MED TEAM 1 (CFR02)

C205

HSKP (JANC1)

FAMILY LOUNGE (WRF01)

CONSULT (OFCD2)

STAFF TLT (TNPG1)

228B

LOCKERS (LR001)

228A

STAFF LOUNGE (SL001)

PANTRY (NCWD1)

CHAPLAIN OFFICE (OFA07)

C219

RT EQUIPMENT STORAGE

C210

RT CLEAN

C211

ELEC

C207

DATA

C208

RT SOILED

C209

OAA

C217

CORR.

C2-03

CORR.

2CORR.

RT OFFICE (OFA09)

C203

RT SHARED OFFICE (OFA07)

C202

OFFICE ICU

C213

DAYTURNIST (OFA09)

C214

1-AC

2ND FLR NURSE MAN. & ASSIST.

C206

24"ø E(SA)

A6

FD

"x

E (R

A

"x

E A

A11

A10

FD

FD

36"x18" RA

S-3

"x

S A

S-2

S-2

S-2

S-1A

E-1A

S-1

S-2

S-2

S-3

S-2

E-2

E-1A

E-1

"x

S A

"x

S A

S-1

S-2

R-1

R-2

E-1

S-1

S-3

S-2

R-3

R-2

A17

20"x12" SA16"x12" SA

"x

S A

"x

S A

10"x14" SA

S-3

S-3

S-3

S-3

S-3

S-3

R-5

R-5

S-2

S-3

S-1

S-1

12"ø SA

R-1

R-3

S-1

12"x12" EA

"x

E A 1

"x

E A

"x

E A

14"x12" SA12"x12" SA

"x

S A

CLOSET

C216

R-2

R-2

FD

FD

S-2

"x

S A

S-5

"x

R A

26"x20" RA

"x

R A

"x

R A

14"x14" RA

S-2

R-4

"ø

S A

"x

R A

R-5

10"x8" RA

A18

8"x12" SA

"x

S A

R-2

R-2

R-3

1-V

2.1

1-V

2.2 1-V

2.3

1-V

2.5 1-V

2.6

1-V

2.8

1-V

2.7 1-V

2.12 1-V

2.13

1-V

2.11

1-V

2.10

1-V

2.15

1-V

2.14

1-V

2.4

"x

S A

"x

S A

S-1

A24

1-V

2.9

R-2

S-6

S-6

R-7

BAS PANEL

R-2

DSA37

DS

DS

A37

A37

A41

VAV TERMINAL

UNIT CLEARANCE.

TYPICAL.

8"x10" SA

2ND FLOOR

ADDITION

SHADE INDICATES

EXISTING AREA BEYOND

PRIMARY SCOPE OF

WORK, TYPICAL

1ST FLOOR

2ND FLOOR

3RD FLOOR

3RD FLOOR

ADDITION

AREA OF RENOVATION

BUILDING 1C

BUILDING 1

AREA OF RENOVATION

BID DEDUCTIVE ALTERNATE 4

FOR THE 3RD FLOOR OF B1C, FULLY BUILD OUT ROOMS C306, C307, C308, C309 AND C310. FOR THE 2ND FLOOR OF B1C, FULLY

BUILD OUT ROOMS C207 AND C208. THE REMAINDER OF THE INTERIOR SPACES TO BE FINISHED WITH CARPET TILE, PAINT, AND ACT CEILINGS, WITH SMALL POWER POLES FOR ELECTRIC AND DATA. THE HVAC TO BE REDUCED TO 3 ZONES IN EACH

SPACE.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

CMTA CONSULTING ENGINEERS, INC

10411 MEETING STREET

PROSPECT, KY 40059

FULLY SPRINKLERED

C U s e rs \j ri g g s \D o c u m e n ts

\V K

M R

M

E C

H R jr ig g s S

B J M

N .r v t

/2 /2

:5

:2

P M

MH101

HVAC PLAN - SECOND FLOOR

GUIDON DESIGN INC.

1221 N PENNSYLVANIA STREET

INDIANAPOLIS, IN 46202

(502)326-3085(502)326-3085

VA WICHITA - MED/SURG BEDS

FOR PATIENT PRIVACY

WICHITA, KANSAS

589-701

1 & 1C

05/22/2020

BID DOCUMENTS

4' 8' 32'16'0

1/8" = 1'-0"

24'2'

SCALE: 1/8" = 1'-0"

HVAC PLAN - SECOND FLOOR

TAGGED NOTES

A6 34" DIA. UP FROM BASEMENT. TRANSITION TO 26" DIA. AFTER

SECOND FLOOR TAKEOFF.

A10 CONNECT TO EXISTING 12"x12" EA DUCT. ROUTE 12"x12" EA UP

THRU THIRD FLOOR.

A11 CONNECT TO EXISTING 16"x12" ISOLATION EXHGAUST DUCT.

ROUTE UP THRU THIRD FLOOR.

A17 12" DIA. EA DUCT UP FROM FIRST FLOOR. PROVIDE FIRE

DAMPER AT FLOOR PENETRATION.

A18 14"x12" EA DUCT UP TO THIRD FLOOR. PROVIDE FIRE DAMPER

AT FLOOR PENETATION.

A24 24"x18" EA/RELIEF DUCT UP FROM FIRST FLOOR, CONTINUE

THRU THIRD FLOOR.

A37 DUCT SMOKE DETECTOR

A41 COORDINATE FLOOR PENETRATION WITH STRUCTURE.

OFFSET/SHIFT DUCT AS REQUIRED TO PENETRATE BETWEEN

STRUCTURAL JOISTS.

N

SCALE: NONE

KEYPLAN

GENERAL MECHANICAL NOTES:

A. REFER TO SHEET MM001 FOR GENERAL NOTES.

Revisions: Date:

Addendum #5 11/24/2020

TERMINAL UNIT

DUCT RUNOUT

SCHEDULE

MARK

INLET DUCT

SIZE

1-CV 08 8"

1-CV 10 10"

1-V 04 4"

1-V 05 5"

1-V 06 6"

1-V 07 7"

1-V 08 8"

1-V 09 9"

1-V 10 10"

1-V 16 16"

GRD RUNOUT

SCHEDULE

SYMBOL

RUNOUT DUCT

SIZE

S-1 6"Ø

S-1A 6"Ø

S-2 8"Ø

S-3 10"Ø

S-4 12"Ø

S-5 12"x8"

S-6 8"Ø

R-1 6"Ø

R-2 8"Ø

R-3 10"Ø

R-4 12"Ø

R-5 12"x8"

R-6 14"Ø

R-7 10"Ø

E-1 6"Ø

E-1A 6"Ø

E-2 8"Ø

E-2A 8"Ø

E-4 12"Ø

Refer to architectural sheet GI102. Plan indicates spaces for deductive Alternate No. 4. Spaces to be fully built out (1C) shall have HVAC as indicated on plans. The remaining “open” space (1C) shall be served by 3 vav terminal units providing 3 zones (approx. 900 cfm each terminal unit). Each unit shall be complete with HW piping, thermostats, low pressure supply and return duct, and grilles and diffusers to provide even airflow for space. Max. supply cfm per diffuser shall be 300 cfm. 1

DN

0.8 1.5 2.8 4.6

MM

K.2K.2

J.3J.3

H.9H.9

F.8F.8

6.9

6.9

6.1

6.1

E E

D D

C C

B B

A A

F F

G G

I I

13 14 15 16

HH

F.1 F.1

JJ

KK

LL

6 75

EXISTING 1ST

FLOOR ROOF

BELOW

EXISTING 2ND

FLOOR ROOF

BELOW

EXISTING 2ND

FLOOR ROOF

BELOW

UP

UP

INPATIENT OFFICE (OFA07)

C304

PSA OFFICE (OFA07)

C303

OFFICE (OFA07)

C302

STORAGE (SRSE1)

C301

PT TREATMENT

C307

NOD SUPER(OFA09)

C314

NOD SHARED (OFA09)

C315

HSKPG (JANC1)

CONFERENCE (CFR02)

C316

PUBLIC TLT (TNPG1)

CLEAN SUPPLY (LCCL2)

TLT (TSPG1)

355A

PATIENT ROOM (BRSM1)

PATIENT ROOM (BRSM1)

240 SF

TLT (TSPG1)

356A

PATIENT ROOM (BRSM1)

TLT (TSPG1)

357A

MOBILE X-RAY ALCOVE (XRM01)

TLT (TSPG1)

363B

AIRBORNE INF. ISO. PT RM (BRSM1)

SOILED UTILITY (SRSE1)

TLT (TSPG1)

366A

69 SF

PATIENT ROOM (BRSM1)

259 SF

PATIENT ROOM (BRSM1)

TLT (TSPG1)

367A

PATIENT ROOM (BRSM1)

TLT (TSPG1)

369A

PATIENT ROOM (BRSM1)

TLT (TSPG1)

372A

BARIATRIC PATIENT ROOM (BRMS1)

260 SF

CHARTING (OFA07)

BARIATRIC TLT (TSPG1)

371A

PATIENT ROOM (BRSM1)

NURSE STATION (NSTA1)

CONSULT (DL001)

FAMILY LOUNGE (WRF01)

CLEAN LINEN

STAFF TLT (TNPG1)

337B

LOCKERS (LR001)

337A

STAFF LOUNGE (SL001)

PANTRY (NCWD1)

GENERAL STORAGE

C305

CORR.

3-1

OFFICE

C311

ASSIST. MAN.

C312

NURSE MAN.

C313

OFFICE

C318

OFFICE

C319

CORR.

C3-02

OFFICE

C317

MED RM (MEDP1)

ELEC CLOSET

ANTE RM

363A

NOURISH (NCWD1)

360A

1-AC

DATA CLOSET

C310

ELEC CLOSET

C309

PROSTHETICS/LOGISTICS STORAGE

C308

WOUND OFFICE (4 STAFF)

C320

OFFICE

C306

26"x20" RA

WORKSTATION (OFA07)

NURSE STATION (NSTA1)

NURSE WORK ROOM (WRCH1)

EQUIP STOR

FD

30"x20" SA

"ø

S A

A5

A8

CORR.

3CORR.

CORR.

3-2

S-2

S-1

S-2

S-1

S-1

S-1A

S-3

S-3

S-1A

S-3

S-1A

S-3

S-2

S-3

S-3

S-1A

S-2

S-2

S-1A

S-1A

S-1

S-1

S-2

E-1A

S-1A

E-2A

E-1A

E-1A

E-1A

E-1A

S-3

275S-2

E-1

S-1A

E-2A

E-2A

S-2

E-1A

S-3

S-3

S-3

S-3

S-2

S-2

S-2

S-2

S-2

S-2

S-2

S-2

S-2

S-2

S-2

S-2

S-2

S-1

S-1

S-1

S-2

S-2

S-2

S-2

S-2

S-2

S-1

E-2

S-2

S-2

S-2

E-2

165E-1A

S-3

S-2

S-2

10"x12" SA

S-2

10"x12" SA

"ø

S A

S-1

"ø

S A

"ø

S A

10"x12" SA

10"x12" SA

1-V

3.32

1-CV

3.34

E-4

1-V

3.17

S-5

"x

S A

"x

S A

"x

S A

"x

S A

20"x16" SA

16"ø SA

"ø

S A

12"x10" SA BELOW

18"x12" SA

12"x10" SA

"ø

S A

"ø

S A

S-2

12"x10" SA

S-2

8"x6" SA

R-5

R-2

R-2

200 R-2

16"x14" RA

R-5

"ø

R A

R-2

10"x8" EA

R-2

R-2

E-1A

E-1A

STAFF TLT (TNPG1)

22"x18" SA

24"x20" RA

18"x12" SA

20"x16" RA

16"x16" EA

R-5

A16

R-2

"x

R A

"x

R A

S-2

S-2

20"x20" EA 30"x20" SA

8"x10" SA

10"ø SA

12"x10" SA

16"x12" SA

"x

S A

26"x20" RA

S-5

"x

S A

S-2

R-2

R-5

R-2

R-2

R-2

R-2

R-2

R-2

R-2

R-2

"x

R A

"x

R A

14"x12" RA

1-V

3.26

1-V

3.28

1-VAV

3.22

A19

FD

FD

A21

A20

A22 A23

"x

S A

12"x8" SA

24"x20" RA

10"x12" SA

HAC CLOSET

A28

TLT (TSPG1)

368A

R-2

R-2

R-3

R-2

FD

"x

R A

A29

14"x14" RA

"x

R A

E-1

R-3

8"x8" EA

"x

E A

8"x8" EA

A30

10"x14" EA

A32

A31

A31

R-2

1-V

3.12

1-V

3.13

1-V

3.3

1-V

3.16

1-V

3.15

1-V

3.35

1-V

3.18

1-V

3.31

1-V

3.30

1-V

3.27

1-V

3.29

1-V

3.11

1-V

3.14

1-V

3.21

1-V

3.23 1-V

3.24 1-V

3.25

1-CV

3.36

1-V

3.9

1-V

3.4

1-V

3.1

1-V

3.2

1-V

3.5

1-V

3.7

1-V

3.10

1-V

3.6

24"x20" SA

A35 A3614"x12" EA

S-2

S-2

FD

10"x8" EA

"x

E A1-V

3.8

1-V

3.33

R-2

8"x8" SA

1-V

3.19

"x

R A

1-V

3.20

20"x20" RA

A7

10"x10" SA

S-2

"x

R A

10"x10" RA

MEDGAS

FDFD

E-2

8"x8" EA

R-1A

BAS PANEL

BAS PANEL

A37 A37

DS DS

DS

DSA37

A37

A38

A38

A7

"x

R A

A41

VAV TERMINAL

UNIT CLEARANCE.

TYPICAL.

VAV TERMINAL

UNIT CLEARANCE.

TYPICAL.

"ø

S A

2ND FLOOR

ADDITION

SHADE INDICATES

EXISTING AREA BEYOND

PRIMARY SCOPE OF

WORK, TYPICAL

1ST FLOOR

2ND FLOOR

3RD FLOOR

3RD FLOOR

ADDITION

AREA OF RENOVATION

BUILDING 1C

BUILDING 1

AREA OF RENOVATION

FOR THE 3RD FLOOR OF B1C, FULLY BUILD OUT ROOMS C306, C307, C308, C309 AND C310. THE REMAINDER OF THE INTERIOR

SPACE TO BE FINISHED WITH CARPET TILE, PAINT, AND ACT CEILINGS, WITH SMALL POWER POLES FOR ELECTRIC AND DATA.

THE HVAC TO BE REDUCED TO 3 ZONES IN THIS SPACE. FULLY BUILD OUT THE 2ND FLOOR.

BID DEDUCTIVE ALTERNATE 3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

CMTA CONSULTING ENGINEERS, INC

10411 MEETING STREET

PROSPECT, KY 40059

FULLY SPRINKLERED

C U s e rs \j ri g g s \D o c u m e n ts

\V K

M R

M

E C

H R jr ig g s S

B J M

N .r v t

/2 /2

:5

:3

P M

MH102

HVAC PLAN - THIRD FLOOR

GUIDON DESIGN INC.

1221 N PENNSYLVANIA STREET

INDIANAPOLIS, IN 46202

(502)326-3085(502)326-3085

VA WICHITA - MED/SURG BEDS

FOR PATIENT PRIVACY

WICHITA, KANSAS

589-701

1 & 1C

05/22/2020

BID DOCUMENTS

4' 8' 32'16'0

1/8" = 1'-0"

24'2'

SCALE: 1/8" = 1'-0"

HVAC PLAN - THIRD FLOOR

TAGGED NOTES

A5 26" DIA. UP FROM SECOND FLOOR.

A7 30"x30" RA DUCT UP TO 1-RTU-1 ON ROOF.

A8 28"x28" RA DUCT UP FROM SECOND FLOOR.

A16 12"x12" EA DUCT UP FROM SECOND FLOOR. CONNECT TO 16"x16" EA.

A19 20"x20" EA UP. TRANSITION TO 22" DIA. AND ROUTE THRUU

ROOF.

A20 26"x20" RA DUCT DN TO SECOND FLOOR.

A21 24"x16" SA DUCT DN TO SECOND FLOOR.

A22 50"x20" OA DUCT UP FROM FIRST FLOOR.

A23 ROUTE 50"x20" OVER AND UP THRU ROOF TO RELOCATED OA

INTAKE HOOD.

A28 16"x16" EA UP TO ATTIC. PROVIDE FIRE DAMPER AT FLOOR

PENETRATION.

A29 ROUTE 8" DIA. RA FROM BOTTOM OF DUCT TO RA GRILLE.

A30 12"x12" ISOLATION EXHAUST UP TO ATTIC. PROVIDE FIRE

DAMPER AT ATTIC FLOOR.

A31 10"x10" EA UP TO ATTIC. PROVIDE FIRE DAMPER AT ATTIC

FLOOR.

A32 16"x12" ISOLATION EXHAUST UP FROM THIRD FLOOR. PROVIDE

FIRE DAMPER AT ATTIC FLOOR.

A35 14"x12" EA UP FROM SECOND FLOOR. PROVIEDE FIRE DAMPER

AT FLOOR PENETRATION.

A36 14"x12" EA UP TO EF ON ROOF.

A37 DUCT SMOKE DETECTOR

A38 PROVIDE FIRE DAMPER AT FLOOR PENETRATION. PROVIDE

ACCESS PANEL IN WALL FOR ACCESS TO DAMPER.

A41 COORDINATE FLOOR PENETRATION WITH STRUCTURE.

OFFSET/SHIFT DUCT AS REQUIRED TO PENETRATE BETWEEN

STRUCTURAL JOISTS.

SCALE: NONE

KEYPLAN

N

GENERAL MECHANICAL NOTES:

A. REFER TO SHEET MM001 FOR GENERAL NOTES.

Revisions: Date:

Addendum #5 11/24/2020

TERMINAL UNIT

DUCT RUNOUT

SCHEDULE

MARK

INLET DUCT

SIZE

1-CV 08 8"

1-CV 10 10"

1-V 04 4"

1-V 05 5"

1-V 06 6"

1-V 07 7"

1-V 08 8"

1-V 09 9"

1-V 10 10"

1-V 16 16"

GRD RUNOUT

SCHEDULE

SYMBOL

RUNOUT DUCT

SIZE

S-1 6"Ø

S-1A 6"Ø

S-2 8"Ø

S-3 10"Ø

S-4 12"Ø

S-5 12"x8"

S-6 8"Ø

R-1 6"Ø

R-2 8"Ø

R-3 10"Ø

R-4 12"Ø

R-5 12"x8"

R-6 14"Ø

R-7 10"Ø

E-1 6"Ø

E-1A 6"Ø

E-2 8"Ø

E-2A 8"Ø

E-4 12"Ø

Refer to architectural sheet GI102. Plan indicates spaces for deductive Alternate No. 3. Spaces to be fully built out (1C) shall have HVAC as indicated on plans. The remaining “open” space (1C) shall be served by 3 vav terminal units providing 3 zones (approx. 700 cfm each terminal unit). Each unit shall be complete with HW piping, thermostats, low pressure supply and return duct, and grilles and diffusers to provide even airflow for space. Max. supply cfm per diffuser shall be 300 cfm. 1

DN

S

S

S

S

S

S

SD SD

SD

S S

S

SD

S

S

S

SD

DL

DL

PC

P C

S

F F

S

F

S

F

F

FF

F

S

S

S

S

F

F

F F

SD

CCC

C

C C

CC

CC

C C

F

ZL

F

S S S

S

S

SD

SS

S

S

CR

DS

CR

DS

C R

DS

DD

DD

DD

FS

TS

0.8 1.5 2.8 4.6

MM

K.2K.2

J.3J.3

H.9H.9

F.8

6.9

6.9

6.1

6.1

E E

D D

C C

B B

A A

F F

G G

I I

13 14 15 16

HH

F.1 F.1

JJ

KK

LL

6 754321

4.8

B.4 B.4

2D

2D

2D

2D

2D

2D

ICU NURSE MGR

(OFA09)

C212

TOILET/SHOWER

(TNPG1)

C215A

NOCTURNIST

(OFA09)

C215

CHAPEL (RAS01)

C220

RT SHARED OFFICE

(OFA07)

C202

RT OFFICE (OFA09)

C203

MED TEAM 2 (CFR02)

C204

STORAGE (SRSE1)

C201

MED TEAM 1 (CFR02)

C205

HSKP (JANC1)

229 FAMILY LOUNGE

(WRF01)

CONSULT (OFCD2)

STAFF TLT (TNPG1)

228B

LOCKERS (LR001)

228A

STAFF LOUNGE

(SL001)

PANTRY (NCWD1)

CHAPLAIN OFFICE

(OFA07)

C219

CORR.

C2-03

CORR.

C2-02

CORR.

2CORR.

ELEV. LOBBY

2-01

CORR.

2-02

ELEV.

1ELEV

TLT

282A

BEDROOM

TLT

280A

BEDROOM

MEDICATION PREP

BEDROOM

BEDROOM

STAIR

SOILED UTILITY

BEDROOM

HSK

BEDROOM

BEDROOM

TLT

256A

BEDROOM

TLT

254A

WARD SUPPLIES

LOUNGE

LAB

BEDROOM

BEDROOM

BEDROOM

TLT

ELEC. CLOSET

STAIR-E

EQUIP. ROOM

STAIR-C

ELEV.

2ELEV-2

I.T.

ELEV.

2ELEV-1

ELEC

C207

RT CLEAN

C211

RT SOILED

C209

RT EQUIPMENT

STORAGE

C210

OAA

C217

DATA

C208

CLOSET

C216

2ND FLR NURSE

MAN. & ASSIST.

C206

OFFICE ICU

C213

DAYTURNIST

(OFA09)

C214

CORR.

C2-01

2D

2D

2D

2D

2D .

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

T +5' - 0"

2D

2D

EL

ES501

2D

2D

2D

F

F

F F

2D

PRINTER

C

C

2D

T

+4' - 0"

PRINTER

2D

ES501

PT-B

P21P21

P21P21

STOR.

C219A

S15

S15

S14

1-ELLS3E-3

2ND FLOOR

ADDITION

SHADE INDICATES

EXISTING AREA BEYOND

PRIMARY SCOPE OF

WORK, TYPICAL

1ST FLOOR

2ND FLOOR

3RD FLOOR

3RD FLOOR

ADDITION

AREA OF RENOVATION

BUILDING 1C

BUILDING 1

AREA OF RENOVATION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

CMTA CONSULTING ENGINEERS, INC.

10411 MEETING STREET,

PROSPECT, KY 40059

(502)326-3085

GUIDON DESIGN, INC

1221 N PENNSYLVANIA STREET

INDIANAPOLIS, IN 46202

(317) 800-6388

BID DOCUMENTS VA WICHITA - MED/SURG

BEDS FOR PATIENT PRIVACY

589-701

1 & 1C

05/22/2020 PDY RAH

C U s e rs \m le p p in g \D o c u m e n ts \V

K M

R

E L E

C R m le p p in g

E Z

J R

.r v t

/2 /2

:0

:2

P M

ES401

SECOND FLOOR PLAN - SYSTEMS

WICHITA, KANSAS

GENERAL NOTES (SYSTEMS):

A. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS,

AND CASEWORK DETAILS FOR EXACT LOCATIONS OF ALL WALL AND

CEILING MOUNTED ELECTRICAL DEVICES.

B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS

INDICATED ON THE FLOOR PLANS, WITH A MAXIMUM OF THREE (3)

BRANCH CIRCUITS PER HOMERUN. EACH BRANCH CIRCUIT SHALL BE

PROVIDED WITH A DEDICATED NEUTRAL CONDUCTOR. DEDICATED

NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT

CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME

CONDUIT WITH THOSE INDICATED, CONTRACTOR SHALL DERATE ALL

CURRENT CARRYING CONDUCTORS PER NEC 310.15(B)(3), AND UPSIZE

CONDUIT AS REQUIRED PER NEC 300.17 AND ANNEX C. MULTIWIRE

BRANCH CIRCUITS AS DEFINED IN NEC 100 / 210.4 (CIRCUITS SHARING A

COMMON NEUTRAL CONDUCTOR) SHALL NOT BE PERMITTED.

C. IDENTIFY THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES,

SWITCHES, ETC. IN AREA OF CONSTRUCTION. PROVIDE CLEAR

ADHESIVE LABELS WITH BLACK LETTERING. IN HEALTHCARE FACILITIES,

ENGRAVE EMERGENCY DEVICE COVERPLATES IN PATIENT CARE

AREAS. MARK INSIDES OF ALL DEVICE BOXES WITH PANEL AND CIRCUIT

NUMBER.

D. REFER TO "SYSTEM INSTALLATION MATRIX" (ON SYSTEMS LEGEND

SHEET) AND SPECIFICATIONS FOR CONTRACTOR REQUIREMENTS OF

EACH SYSTEM.

E. THE CONTRACTOR SHALL ROUTE ALL ''SYSTEM CONDUIT STUB-UPS'' TO

THE NEAREST CORRIDOR CABLING PATH (SEE ''STUB-UP'' DETAILS).

REFER TO CABLING PATH INSTALLATION DETAIL FOR ADDITIONAL

REQUIREMENTS.

F. CONTRACTOR SHALL PAINT ALL SYSTEMS CONDUIT STUB-UPS LIGHT

BLUE FOR SYSTEMS CABLING INTO THE CORRIDOR CABLING PATH.

PROVIDE PULL STRINGS IN ALL NEW CONDUIT RUNS FOR SYSTEM

CABLING INSTALLATION.

4' 8' 32'16'0

1/8" = 1'-0"

24'2'

SCALE: 1/8" = 1'-0"

SECOND FLOOR PLAN - SYSTEMS

1" = 100'-0"

KEYPLAN

SECOND & THIRD FLOOR ALTERNATE OFFICE CUBICLE AREA

REFER TO THE ARCHITECTURAL PLANS FOR A PROPOSED ‘’OPEN OFFICE’’

AREA LAYOUT ON THE THIRD FLOOR. PROVIDE APPROXIMATELY (20) TYPE

“A2” 2X4 LIGHTS, (6) CEILING TYPE VACANCY SENSOR UNITS, (4) LOW

VOLTAGE LIGHT SWITCHES, (18) QUADRAPLEX RECEPTACLES, (4) FLOOR

FED FURNITURE POWER FEEDS, (4) FLOOR FED FURNITURE DATA FEEDS, (8)

‘4D’ DATA OUTLETS AND (2) FIRE ALARM AUDIO/VISUAL UNITS.

TAGGED NOTES

P21 PROVIDE ONE (1) 1-1/2" CONDUIT FOR DATA AND HDMI CONNECTIONS TO

TV MOUNTED ON WALL IN THIS AREA. CUT, TRENCH, AND PATCH FLOOR AS

REQUIRED. EXTEND CONDUIT TO NEAREST AVAILABLE CABLE PATH.

S14 PROVIDE FOUR (1) 2" CONDUIT SLEEVE(S) THROUGH WALL(S) INDICATED.

INSTALL SLEEVE(S) ABOVE SUSPENDED CEILING (WHERE APPLICABLE).

PROVIDE UL LISTED FIRE-RATED ASSEMBLY AT PENETRATION AS

REQUIRED. REFER TO SLEEVE PENETRATION DETAIL FOR ADDITIONAL

REQUIREMENTS (TYPICAL ALL PENETRATIONS).

S15 PROVIDE DUCT SMOKE DETECTOR. REFER TO FIRE ALARM RISER

DIAGRAM AND MECHANICAL DRAWINGS FOR ADDITIONAL REQUIREMENTS

AND INFORMATION.

Revisions: Date:

S

S S

S

S

S

S

S

S

SDS

S

S

S

S S S

S

S

S

DL

DL

DL

DL

ZL

ZL

DL

DL

DL

S

S

F

S

F

S F

F

F

F

S

F F

S

F

F

F F

SS

S

S

S

DL DL DL

PC

DL

M S

MS

S A

SA

C C

CC

CC

CC

C C

C C

C C

C C

C C

C C

S

S

S

SV

SV

SD S

CC ZL

SD

DL

ZL

CR

DS

DP

F

F F

F

SD

CR

DS

CR

DS

C R

DS

SD

SD

SD

F

S

CR

DS

F S

LPA

DD

DD

DD DD

FS

TS

F

FS

TS

0.8 1.5 2.8 4.6

MM

K.2K.2

J.3J.3

H.9H.9

F.8F.8

6.9

6.9

6.1

6.1

E E

D D

C C

B B

A A

F F

G G

I I

13 14 15 16

HH

F.1 F.1

JJ

KK

LL

6 75

2D

2D

2D

2D

T +5' - 0".

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

2D

T

+5' - 0"

T

+4' - 0"

2D

2D

2D

4D

2D/C

2D/C

2D/C

2D/C

2D/C

2D/C

2D/C

2D/C

2D/C

2D/C

2D

C

2D

2D

2D

ELEC CLOSET

C309

INPATIENT OFFICE

(OFA07)

C304

PSA OFFICE (OFA07)

C303

OFFICE (OFA07)

C302

STORAGE (SRSE1)

C301

PT TREATMENT

C307

NOD SUPER(OFA09)

C314

NOD SHARED

(OFA09)

C315

DATA CLOSET

C310

HSKPG (JANC1)

CONFERENCE

(CFR02)

C316

PUBLIC TLT (TNPG1)

CLEAN SUPPLY

(LCCL2)

TLT (TSPG1)

355A

PATIENT ROOM

(BRSM1)

PATIENT ROOM

(BRSM1)

TLT (TSPG1)

356A

PATIENT ROOM

(BRSM1)

TLT (TSPG1)

357A

NOURISH (NCWD1)

360A

MED RM (MEDP1)

STAFF TLT (TNPG1)

MOBILE X-RAY

ALCOVE (XRM01)

TLT (TSPG1)

363B

AIRBORNE INF. ISO.

PT RM (BRSM1)

SOILED UTILITY

(SRSE1)

TLT (TSPG1)

366A

PATIENT ROOM

(BRSM1)

PATIENT ROOM

(BRSM1)

TLT (TSPG1)

367A

PATIENT ROOM

(BRSM1)

TLT (TSPG1)

369A

PATIENT ROOM

(BRSM1)

TLT (TSPG1)

372A

BARIATRIC PATIENT

ROOM (BRMS1)

CHARTING (OFA07)

BARIATRIC TLT

(TSPG1)

371A

PATIENT ROOM

(BRSM1)

NURSE STATION

(NSTA1)

WORKSTATION

(OFA07)

NURSE WORK ROOM

(WRCH1)

NURSE STATION

(NSTA1)

CONSULT (DL001)

FAMILY LOUNGE

(WRF01)

CLEAN LINEN

STAFF TLT (TNPG1)

337B

LOCKERS (LR001)

337A

STAFF LOUNGE

(SL001)

PANTRY (NCWD1)

EQUIP STOR

TOILET

326A

OBSERVATION

ROOM

CORR.

3-1

OBSERVATION

ROOM

MED

TOILET

325A

EQUIP STOR

ELECT

CLEAN UTIL

ELEV

3ELEV-2

ELEV

3ELEV-1

STAIR

3STAIRC

BIOMED

STAIR

3-STAIR-E

CORR.

C3-02

CORR.

C3-01

CORR.

3CORR.

ELEV.

ELEV. LOBBY

3-01

CORR.

3-02

GENERAL STORAGE

C305

ANTE RM

363A

EQUIP STOR

OFFICE

C311

WOUND OFFICE (4

STAFF)

C320

ASSIST. MAN.

C312

NURSE MAN.

C313

OFFICE

C317

OFFICE

C318

OFFICE

C319

CORR.

3-2

CORR.

C3-03

OFFICE

C306

PROSTHETICS/LOGISTICS

STORAGE

C308

ELEC CLOSET

PT WORKSTATIONS

C307A

TLT (TSPG1)

368A

COPIER

4D

4D

4D

2D

PYXIS

2D S2

HAC CLOSET

ES501

REFER TO ENLARGED VIEWS OF

TYPICAL PATIENT ROOM

ELECTRICAL REQUIREMENTS FOR

SCOPE OF WORK IN HATCHED AREA

REFER TO ENLARGED VIEWS OF

TYPICAL PATIENT ROOM

ELECTRICAL REQUIREMENTS FOR

SCOPE OF WORK IN HATCHED AREA

REFER TO ENLARGED VIEWS OF

TYPICAL PATIENT ROOM

ELECTRICAL REQUIREMENTS FOR

SCOPE OF WORK IN HATCHED AREA

2D

PYXIS

EL

F

F

2D .

2D

F

F

F

F

2D/C

F

S14 S14

S14

S14

ES501

2D/C

1-ELLS3E-4

S17

1-ELLS3E-7

(SEE DETAIL)

1-ELLS3E-8

EXSITING

TELEMETRY/DATA

RACK TO REMAIN

C C C

C

C

C

C

C

C

C

C

C

C

2ND FLOOR

ADDITION

SHADE INDICATES

EXISTING AREA BEYOND

PRIMARY SCOPE OF

WORK, TYPICAL

1ST FLOOR

2ND FLOOR

3RD FLOOR

3RD FLOOR

ADDITION

AREA OF RENOVATION

BUILDING 1C

BUILDING 1

AREA OF RENOVATION

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

CMTA CONSULTING ENGINEERS, INC.

10411 MEETING STREET,

PROSPECT, KY 40059

(502)326-3085

GUIDON DESIGN, INC

1221 N PENNSYLVANIA STREET

INDIANAPOLIS, IN 46202

(317) 800-6388

BID DOCUMENTS VA WICHITA - MED/SURG

BEDS FOR PATIENT PRIVACY

589-701

1 & 1C

05/22/2020 PDY RAH

C U s e rs \m le p p in g \D o c u m e n ts \V

K M

R

E L E

C R m le p p in g

E Z

J R

.r v t

/2 /2

:0

:2

P M

ES402

THIRD FLOOR PLAN - SYSTEMS

WICHITA, KANSAS

4' 8' 32'16'0

1/8" = 1'-0"

24'2'

SCALE: 1/8" = 1'-0"

THIRD FLOOR PLAN - SYSTEMS

1" = 100'-0"

KEYPLAN

GENERAL NOTES (SYSTEMS):

A. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS,

AND CASEWORK DETAILS FOR EXACT LOCATIONS OF ALL WALL AND

CEILING MOUNTED ELECTRICAL DEVICES.

B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS

INDICATED ON THE FLOOR PLANS, WITH A MAXIMUM OF THREE (3)

BRANCH CIRCUITS PER HOMERUN. EACH BRANCH CIRCUIT SHALL BE

PROVIDED WITH A DEDICATED NEUTRAL CONDUCTOR. DEDICATED

NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT

CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME

CONDUIT WITH THOSE INDICATED, CONTRACTOR SHALL DERATE ALL

CURRENT CARRYING CONDUCTORS PER NEC 310.15(B)(3), AND UPSIZE

CONDUIT AS REQUIRED PER NEC 300.17 AND ANNEX C. MULTIWIRE

BRANCH CIRCUITS AS DEFINED IN NEC 100 / 210.4 (CIRCUITS SHARING A

COMMON NEUTRAL CONDUCTOR) SHALL NOT BE PERMITTED.

C. IDENTIFY THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES,

SWITCHES, ETC. IN AREA OF CONSTRUCTION. PROVIDE CLEAR

ADHESIVE LABELS WITH BLACK LETTERING. IN HEALTHCARE FACILITIES,

ENGRAVE EMERGENCY DEVICE COVERPLATES IN PATIENT CARE

AREAS. MARK INSIDES OF ALL DEVICE BOXES WITH PANEL AND CIRCUIT

NUMBER.

D. REFER TO "SYSTEM INSTALLATION MATRIX" (ON SYSTEMS LEGEND

SHEET) AND SPECIFICATIONS FOR CONTRACTOR REQUIREMENTS OF

EACH SYSTEM.

E. THE CONTRACTOR SHALL ROUTE ALL ''SYSTEM CONDUIT STUB-UPS'' TO

THE NEAREST CORRIDOR CABLING PATH (SEE ''STUB-UP'' DETAILS).

REFER TO CABLING PATH INSTALLATION DETAIL FOR ADDITIONAL

REQUIREMENTS.

F. CONTRACTOR SHALL PAINT ALL SYSTEMS CONDUIT STUB-UPS LIGHT

BLUE FOR SYSTEMS CABLING INTO THE CORRIDOR CABLING PATH.

PROVIDE PULL STRINGS IN ALL NEW CONDUIT RUNS FOR SYSTEM

CABLING INSTALLATION.

SECOND & THIRD FLOOR ALTERNATE OFFICE CUBICLE AREA

REFER TO THE ARCHITECTURAL PLANS FOR A PROPOSED ‘’OPEN OFFICE’’

AREA LAYOUT ON THE THIRD FLOOR. PROVIDE APPROXIMATELY (20) TYPE

“A2” 2X4 LIGHTS, (6) CEILING TYPE VACANCY SENSOR UNITS, (4) LOW

VOLTAGE LIGHT SWITCHES, (18) QUADRAPLEX RECEPTACLES, (4) FLOOR

FED FURNITURE POWER FEEDS, (4) FLOOR FED FURNITURE DATA FEEDS, (8)

‘4D’ DATA OUTLETS AND (2) FIRE ALARM AUDIO/VISUAL UNITS.

TAGGED NOTES

S2 ROUTE ONE (1) 1-1/4" CONDUIT FROM POKE-THRU TO STUB UP INSIDE

WALL FOR A/V, HDMI, DATA, ETC. CONNECTIONS BETWEEN POKE THRU

AND TV. COORDINATE EXACT POKE THRU AND TV LOCATION PRIOR TO

ROUGH-IN.

S14 PROVIDE FOUR (1) 2" CONDUIT SLEEVE(S) THROUGH WALL(S) INDICATED.

INSTALL SLEEVE(S) ABOVE SUSPENDED CEILING (WHERE APPLICABLE).

PROVIDE UL LISTED FIRE-RATED ASSEMBLY AT PENETRATION AS

REQUIRED. REFER TO SLEEVE PENETRATION DETAIL FOR ADDITIONAL

REQUIREMENTS (TYPICAL ALL PENETRATIONS).

S17 PROVIDE CONNECTION TO FIRE ALARM SYSTEM FOR AUTOMATIC

RELEASE OF ALL MECHANICALLY HELD DOORS UPON FIRE ALARM

SYSTEM ACTIVATION. REFER TO FIRE ALARM RISER DIAGRAM FOR

ADDITIONAL REQUIREMENTS AND INFORMATION.

Revisions: Date:

JJ

C B

S P C

J

S P C

P C

B I

J J

J J

S

P C

SD

SD

J

J

PC

SPC

CB

BI

SD

S

J J

J

PC

J

J

SPC

CB

BI

PC

S

SD

J J

J

J

J

PC

J

J

.Dc

D6-20(b)

D6-20(a)

D6-20(a)

D6-20(d)

.De

.Df,g

D3-10(e)

D3-10(e)

.Dd

.U

U1U2

(TYP)

L1

B2(f,g)

D6-20

.OS

ST(c)

ST(c)

DS-15

V1

.EL

L5 L5 g f

(TYP)

L12

Da

Dc

.Db

.Da

.Da

GFI/E

+3' - 0"

E

E +4' - 0"

E

E

PATIENT LIFT

CONNECTION

(TYP)

USB

EP

P6

P6

T +7' - 0"

PATIENT ROOM

(BRSM1)

P2

P4

P4

NP

(TYP)

P10

4' - 0"

S1

S1

2D

GFI/E

+3' - 0"

3D/1V

S16

E

D

F

G

I

13 14 15 16

F.1

1EF

1EF

1VFD

1EF12

D9

1-ELEQ3E-4

P23

1-ELEQ3E-5

TLT (TSPG1)

363B

AIRBORNE INF. ISO.

PT RM (BRSM1)

ANTE RM

363A

D6-20(a)

D6-20(d)

D6-20(a)

D6-20(b)

D3-10(e) D3-10(e)

.De .Df,g

B2(f,g) g f

D6-20(a)

.NL

.EL

.Da

.Dc

.Db

ST(c)

ST(c)

.OS

DS-15

D6-20

V1

.Dd

U1

U2 .U

L1

ST(c)

Da

Dc

L5

L5

.Da

Da

GFI/E

GFI/E

+3' - 0"

+3' - 0"

S1

S1

T

+7' - 0"

PATIENT LIFT

CONNECTION

(TYP)

E

E

P4P4

E

EP

P6

P6

NP

P2

E

+4' - 0"

4' - 0" 2D

3D/1V

S16

(TYP)

P10

B B

A A

13 14

E

GFI/E

GFI/E

E

T +7' - 0"

PATIENT LIFT

CONNECTION

(TYP)

S1 S1 E

+4' - 0"

USB

P2.

E

P4 P4

NP

3D/1V

S16

P6

P6

EP

(TYP)

P10

B B

A A

13 14 g f

Da

D6-20(a)

D6-20(b)

.EL

.NL

.Da .Db

.Dc

Db

ST(c)

ST(c)

D6-20(a)

Dc

U2

U2

.De .Da

.Df,g

B2(f,g)

D3-10(e)

D3-10(e)

.Dd

L5

L5

.OS

V1

DS-15

D6-20

D6-20(a)

D6-20(d)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

CMTA CONSULTING ENGINEERS, INC.

10411 MEETING STREET,

PROSPECT, KY 40059

(502)326-3085

GUIDON DESIGN, INC

1221 N PENNSYLVANIA STREET

INDIANAPOLIS, IN 46202

(317) 800-6388

BID DOCUMENTS VA WICHITA - MED/SURG

BEDS FOR PATIENT PRIVACY

589-701

1 & 1C

05/22/2020 PDY RAH

C U s e rs \m le p p in g \D o c u m e n ts \V

K M

R

E L E

C R m le p p in g

E Z

J R

.r v t

/2 /2

:0

:2

P M

ES502

ENLARGED PLANS

WICHITA, KANSAS

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

ENLARGED 3RD FLOOR PLAN - TYPICAL

PATIENT ROOM - LIGHTING

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

ENLARGED 3RD FLOOR PLAN - TYPICAL

PATIENT ROOM - POWER / SYSTEMS

GENERAL NOTES (ENLARGED AND TYPICAL):

A. ALL ROOM LAYOUTS ARE TYPICAL AND MAY VARY OR MIRROR OTHER

ASSOCIATED ROOMS. CONTRACTOR SHALL REFER TO ARCHITECTURAL

ELEVATIONS AND COORDINATE EACH ROOM PRIOR TO ROUGH-IN.

GENERAL NOTES (LIGHTING):

A. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS,

AND CASEWORK DETAILS FOR EXACT LOCATIONS OF ALL WALL AND

CEILING MOUNTED ELECTRICAL DEVICES.

B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS

INDICATED ON THE FLOOR PLANS, WITH A MAXIMUM OF THREE (3)

BRANCH CIRCUITS PER HOMERUN. EACH BRANCH CIRCUIT SHALL BE

PROVIDED WITH A DEDICATED NEUTRAL CONDUCTOR. DEDICATED

NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT

CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME

CONDUIT WITH THOSE INDICATED, CONTRACTOR SHALL DERATE ALL

CURRENT CARRYING CONDUCTORS PER N.E.C. #310.15(B)(3), AND

UPSIZE CONDUIT AS REQUIRED PER N.E.C. #300.17 AND ANNEX

C. MULTIWIRE BRANCH CIRCUITS AS DEFINED IN N.E.C #100 / 210.4

(CIRCUITS SHARING A COMMON NEUTRAL CONDUCTOR) SHALL NOT BE

PERMITTED.

C. ALL DEVICE COVERPLATES SHALL BE #302 STAINLESS STEEL. IDENTIFY

THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES, SWITCHES,

ETC. IN AREA OF CONSTRUCTION. ENGRAVE DEVICE COVERPLATES

FOR IDENTIFICATION. ALL JUNCTION BOXES (LABEL INTERIOR OF BOX

WHERE "IN WALL" SWITCHES AND OUTLET BOXES) SHALL BE LABELED

WITH THE VOLTAGE, PHASE, CIRCUIT NUMBER AND PANEL OF ORIGIN. A

BLACK MARKER SHALL BE ACCEPTABLE FOR JUNCTION BOX LABELING.

ALL CONDUCTORS IN A SINGLE CONDUIT / CONDUIT BODY SHALL

ORIGINATE FROM THE SAME PANEL. THE GROUND CONDUCTOR SHALL

BE BONDED TO THE BOX AT ANY DEVICE OR JUNCTION BOX WHICH HAS

CONNECTIONS IN IT.

D. LOCATE CHAIN-HUNG INDUSTRIAL FIXTURES IN MECHANICAL ROOMS TO

AVOID DUCTWORK AND PIPING, TO MAXIMIZE AVAILABLE LIGHT. SPACE

AROUND EQUIPMENT, AIR HANDLERS, ETC. TO PROVIDE ADEQUATE

LIGHTING TO ALL AREAS OF ROOM. PROVIDE ADDITIONAL FIXTURES OF

SAME TYPE AS NEEDED TO FULFILL THIS REQUIREMENT.

E. LOCATE EXIT SIGNS FOR MAXIMUM VIEWING AREA TO IDENTIFY EGRESS

PATHS AS INDICATED ON PLANS. COORDINATE LOCATIONS SUCH THAT

ARCHITECTURAL FEATURES OR EQUIPMENT FROM OTHER TRADES DO

NOT OBSTRUCT VIEW.

F. WHERE EXIT SIGNS OR EMERGENCY BATTERY PACKS ARE PROVIDED,

THEY SHALL BE CONNECTED TO AN UNSWITCHED LINE.

G. LUMINAIRES INDICATED WITH MULTI-LEVEL SWITCHING SHALL HAVE

SIMILAR LAMPS CONTROLLED TOGETHER, I.E. INBOARD AND OUTBOARD

LAMPS OR RIGHT AND LEFT HAND LAMPS.

H. ALL LIGHTING FIXTURE LENSES, PARABOLIC LOUVERS, DOWNLIGHTING

ALZAK CONES AND "PARACUBE" LOUVERS SHALL BE HANDLED WITH

COTTON GLOVES DURING INSTALLATION AND LAMPING TO AVOID

FINGERPRINTS OR DIRT DEPOSITS. IT IS PREFERRED THAT FIXTURES

BE SHIPPED AND INSTALLED WITH CLEAR PLASTIC BAGS TO PROTECT

LOUVERS. AT CLOSE OF PROJECT, AND AFTER CONSTRUCTION AIR

FILTERS ARE CHANGED, REMOVE BAGS. ANY LOUVER OR CONE

SHOWING DIRT OR FINGER PRINTS SHALL BE CLEANED WITH SOLVENT

RECOMMENDED BY THE MANUFACTURER, OR REPLACED AS

NECESSARY IN ORDER TO TURN OVER TO THE OWNER NEW FIXTURES

AT OCCUPANCY.

I. RECESSED LUMINAIRES SHALL BE SECURED SUCH THAT THE FORCE

REQUIRED INSERTING LAMPS, TRIMS, LENSES, LOUVERS, OR DOOR

FRAMES DOES NOT SHIFT HOUSING. ALL TRIMS SHALL BE COMPLETELY

FLUSH WITH FINISHED CEILINGS AT COMPLETION OF CONSTRUCTION.

J. CONTRACTOR SHALL PROVIDE UNSWITCHED CONDUCTOR TO ALL EXIT

SIGNS, EMERGENCY INVERTER BATTERY PACKS, AND NIGHT LIGHTS AS

REQUIRED.

GENERAL NOTES (POWER / SYSTEMS):

A. THIN SOLID LINES INDICATE EXISTING ITEMS TO REMAIN (U.O.N.) AND THICK

SOLID LINES INDICATE NEW WORK.

B. ALL NEW WIRING SHALL BE #12 WITH A #12 INSULATED GROUND WIRE (U.O.N.).

CONDUIT SHALL BE 3/4'' MINIMUM.

C. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS, AND

CASEWORK DETAILS FOR EXACT LOCATIONS OF ALL WALL AND CEILING

MOUNTED ELECTRICAL DEVICES.

D. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS INDICATED

ON THE FLOOR PLANS, WITH A MAXIMUM OF THREE (3) BRANCH CIRCUITS PER

HOMERUN. EACH BRANCH CIRCUIT SHALL BE PROVIDED WITH A DEDICATED

NEUTRAL CONDUCTOR. DEDICATED NEUTRAL CONDUCTORS SHALL BE

CONSIDERED CURRENT CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN

THE SAME CONDUIT WITH THOSE INDICATED, CONTRACTOR SHALL DERATE

ALL CURRENT CARRYING CONDUCTORS PER NEC 310.15(B)(3), AND UPSIZE

CONDUIT AS REQUIRED PER NEC 300.17 AND ANNEX C. MULTIWIRE BRANCH

CIRCUITS AS DEFINED IN NEC 100 / 210.4 (CIRCUITS SHARING A COMMON

NEUTRAL CONDUCTOR) SHALL NOT BE PERMITTED.

E. IDENTIFY THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES,

SWITCHES, ETC. IN AREA OF CONSTRUCTION. PROVIDE CLEAR ADHESIVE

LABELS WITH BLACK LETTERING. IN HEALTHCARE FACILITIES, ENGRAVE

EMERGENCY DEVICE COVERPLATES IN PATIENT CARE AREAS. MARK INSIDES

OF ALL DEVICE BOXES WITH PANEL AND CIRCUIT NUMBER.

F. RECEPTACLES THAT ARE CONTROLLED BY AN AUTOMATIC MEANS SUCH AS

OCCUPANCY SENSOR OR ENERGY MANAGEMENT SYSTEM SHALL BE MARKED

IN ACCORDANCE WITH NEC 406.3(E).

G. LOCATIONS OF ELECTRICAL CONNECTIONS AND LOCAL DISCONNECTS SHALL

BE COORDINATED WITH MECHANICAL AND PLUMBING CONTRACTORS TO

ENSURE ACCESS AND WORKING CLEARANCE IS MAINTAINED PER NEC.

NOTIFY OTHER TRADES OF REQUIRED CLEARANCE AREAS TO AVOID

ROUTING OF OTHER SYSTEMS IN THESE AREAS. DO NOT INSTALL ELECTRICAL

EQUIPMENT OVER EQUIPMENT NAMEPLATES OR ACCESS PANELS OR

THROUGH ACCESS/MAINTENANCE CLEARANCES OF EQUIPMENT BY OTHER

TRADES.

H. NO CONDUIT SHALL BE INSTALLED UNDERGROUND, EXCEPT FOR

DISTRIBUTION EQUIPMENT FEEDERS, UNLESS REQUIRED FOR THE

APPLICATION (FLOOR BOXES, ISLANDS, ETC,) OR SPECIFICALLY INDICATED AS

SUCH IN CONSTRUCTION DOCUMENTS. NO CONDUIT SHALL BE INSTALLED

WITHIN CONCRETE SLABS.

I. ALL DEVICE COVERPLATES SHALL BE #302 STAINLESS STEEL. IDENTIFY THE

PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES, SWITCHES, ETC. IN

AREA OF CONSTRUCTION. ENGRAVE DEVICE COVERPLATES FOR

IDENTIFICATION. ALL JUNCTION BOXES (LABEL INTERIOR OF BOX WHERE "IN

WALL"SWITCHES AND OUTLET BOXES) SHALL BE LABELED WITH THE

VOLTAGE, PHASE, CIRCUIT NUMBER AND PANEL OF ORIGIN. A BLACK MARKER

SHALL BE ACCEPTABLE FOR JUNCTION BOX LABELING. ALL CONDUCTORS IN A

SINGLE CONDUIT / CONDUIT BODY SHALL ORIGINATE FROM THE SAME PANEL.

THE GROUND CONDUCTOR SHALL BE BONDED TO THE BOX AT ANY DEVICE

OR JUNCTION BOX WHICH HAS CONNECTIONS IN IT.

J. ALL CEILING MOUNTED DEVICES, FIXTURES, ETC. SHALL BE INSTALLED

COMPLETELY FLUSH WITH FINISHED CEILING. CAREFULLY COORDINATE WITH

DRYWALL CONTRACTOR TO ENSURE A FLUSH INSTALLATION. DRYWALL

CONTRACTOR SHALL TAPE, MUD, AND SAND AS NEEDED. NO GAP BETWEEN

DEVICE/FIXTURE AND CEILING WILL BE ACCEPTABLE. IF DEEMED THE ONLY

SOLUTION BY THE ARCHITECT OR ENGINEER, THIS CONTRACTOR SHALL

PROVIDE AN APPROVED SEALANT TO SEAL ANY SUCH GAPS THAT EXIST. A

FINAL WALK-THROUGH SHALL BE SCHEDULED WITH THE OWNER TO

APPROVE THE FINISHED CEILING CONDITION.

K. NO CONDUIT, SUPPORTS, ETC. SHALL BE RUN THROUGH ACCESS

CLEARANCES OF EQUIPMENT BY OTHER TRADES (I.E. VAV BOXES).

COORDINATE WITH ALL TRADES PRIOR TO CONSTRUCTION.

L. WHERE ANY RECEPTACLE IS LOCATED WITHIN 6'-0" OF SINK, CONTRACTOR

SHALL PROVIDE "GFCI" TYPE OUTLET OR CONNECT CIRCUIT TO A 20A/1P GFCI

TYPE CIRCUIT BREAKER. REFER TO ARCHITECTURAL PLANS FOR SINK

LOCATIONS.

M. PROVIDE COORDINATION DRAWINGS FOR REVIEW (BETWEEN FURNITURE

VENDOR, LAB EQUIPMENT VENDORS & CONTRACTOR) PRIOR TO ROUGH-IN(S).

TAGGED NOTES

D9 EXISTING EQUIPMENT INDICATED TO REMAIN AS IS.

L1 PROVIDE 120V/1Ø POWER FROM RECEPTACLE CIRCUIT SERVING

COUNTER TOP RECEPTACLES BELOW.

L5 REFER TO FLOOR PLANS FOR LIGHTING CIRCUIT CONTINUATION.

L12 REFER TO ARCHITECT'S DRAWINGS, DETAILS, ELEVATIONS, ETC. FOR

ADDITIONAL REQUIREMENTS, EQUIPMENT LOCATIONS, ETC. FOR ALL

TYPICAL PATIENT ROOMS.

P2 PROVIDE 120V/1Ø CONNECTION FOR PATIENT LIFT. VERIFY EXACT

REQUIREMENTS WITH MANUFACTURER'S RECOMMENDATIONS PRIOR TO

ROUGH-IN.

P4 JUNCTION BOX MOUNTED ABOVE ACCESSIBLE CEILING DIRECTLY ABOVE

PATIENT BED HEAD WALL UNIT. CONNECT NORMAL AND EMERGENCY

CRITICAL BRANCH POWER CIRCUITS TO HEAD WALL UNIT AS REQUIRED.

REFER TO ARCHITECT'S PATIENT HEADWALL UNIT DETAIL FOR

ADDITIONAL REQUIREMENTS AND INFORMATION.

P6 REFER TO FLOOR PLANS FOR POWER CIRCUITING CONTINUATION.

P10 REFER TO ARCHITECT'S DRAWINGS, DETAILS, ELEVATIONS, ETC. FOR

ADDITIONAL REQUIREMENTS, EQUIPMENT LOCATIONS, ETC. FOR ALL

TYPICAL PATIENT ROOMS.

P23 ROUTE THROUGH MANUFACTURER'S INTEGRAL DISCONNECT SWITCH.

REFER TO MECHANICAL SCHEDULES FOR ADDITIONAL REQUIREMENTS

AND INFORMATION.

S1 NURSE CALL PATIENT BED INTERFACE AND CODE BLUE STATION TO BE

INSTALLED IN PRE-MANUFACTURED HEAD WALL. COORDINATE EXACT

REQUIREMENTS WITH FINAL HEADWALL SELECTIONS AND

MANUFACTURER'S SPECIFICATIONS. REFER TO ARCHITECT'S PATIENT

HEADWALL UNIT DETAIL FOR ADDITIONAL REQUIREMENTS AND

INFORMATION.

S16 PROVIDE JUNCTION BOX MOUNTED ABOVE ACCESSIBLE CEILING

DIRECTLY ABOVE PATIENT BED HEAD WALL UNIT FOR DATA CONNECTION

AS REQUIRED. REFER TO ARCHITECT'S PATIENT HEADWALL UNIT DETAIL

FOR ADDITIONAL REQUIREMENTS AND INFORMATION.

GENERAL NOTES (ROOF):

A. REFER TO POWER, SYSTEMS, AND LIGHTING PLANS FOR GENERAL

NOTES APPLICABLE TO INTERIOR SPACES SHOWN ON THIS PLAN.

B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS

INDICATED ON THE FLOOR PLANS, WITH A MAXIMUM OF THREE (3)

BRANCH CIRCUITS PER HOMERUN. EACH BRANCH CIRCUIT SHALL BE

PROVIDED WITH A DEDICATED NEUTRAL CONDUCTOR. DEDICATED

NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT

CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME

CONDUIT WITH THOSE INDICATED, CONTRACTOR SHALL DERATE ALL

CURRENT CARRYING CONDUCTORS PER NEC 310.15(B)(3), AND UPSIZE

CONDUIT AS REQUIRED PER NEC 300.17 AND ANNEX C. MULTIWIRE

BRANCH CIRCUITS AS DEFINED IN NEC 100 / 210.4 (CIRCUITS SHARING A

COMMON NEUTRAL CONDUCTOR) SHALL NOT BE PERMITTED.

C. IDENTIFY THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES,

SWITCHES, ETC. IN AREA OF CONSTRUCTION. PROVIDE ENGRAVED

LAMACOID LABLES FOR ALL EXTERIOR DEVICES. MARK INSIDES OF ALL

DEVICE BOXES WITH PANEL AND CIRCUIT NUMBER.

D. PROVIDE UNI-STRUT AS REQUIRED FOR MOUNTING OF ALL DEVICES ON

ROOF. COORDINATE WITH ROOFING CONTRACTOR PRIOR TO

CONSTRUCTION FOR ALL PENETRATIONS. SEAL PENETRATIONS AS

REQUIRED PER ROOFING CONTRACTOR AND ROOFING

MANUFACTURER'S RECOMMENDATIONS AS REQUIRED TO MAINTAIN

ROOF WARRANTY. PROVIDE CURBS AND/OR FLASHED BOOTS AT ALL

DEVICES AND PENETRATIONS.

E. CONDUITS SHALL PENETRATE ROOF FROM BELOW AS CLOSE TO FINAL

ROOF EQUIPMENT TERMINATION POINT AS POSSIBLE. SUPPORT ALL

ROOF MOUNTED CONDUITS AT INTERVALS NOT EXCEEDING 10 FEET

WITH STRUT-BASED SUPPORT SYSTEM. SUPPORT SYSTEM TO BE

CADDY PYRAMID ST SERIES OR APPROVED EQUAL.

F. ALL CONDUIT EXPOSED TO DIRECT SUNLIGHT SHALL BE AT LEAST 12''

ABOVE THE ROOF-TOP. NO CONDUIT SHALL BE EXPOSED TO DIRECT

SUNLIGHT BELOW THIS HEIGHT.

G. WHERE RACEWAY OR CONDUCTORS ARE INSTALLED EXPOSED ON

ROOF, DERATE AMPACITY OF CONDUCTORS IN ACCORDANCE WITH

NEC.

H. LOCATIONS OF ELECTRICAL CONNECTIONS AND LOCAL DISCONNECTS

SHALL BE COORDINATED WITH MECHANICAL AND PLUMBING

CONTRACTORS TO ENSURE ACCESS AND WORKING CLEARANCE IS

MAINTAINED PER NEC. NOTIFY OTHER TRADES OF REQUIRED

CLEARANCE AREAS TO AVOID ROUTING OF OTHER SYSTEMS IN THESE

AREAS. DO NOT INSTALL ELECTRICAL EQUIPMENT OVER EQUIPMENT

NAMEPLATES OR ACCESS PANELS OR THROUGH

ACCESS/MAINTENANCE CLEARANCES OF EQUIPMENT BY OTHER

TRADES.

I. PROVIDE MAINTENANCE RECEPTACLE WITHIN 25 FT OF EACH

MECHANICAL UNIT AS REQUIRED BY NEC. COORDINATE INSTALLATION

LOCATIONS WITH FINAL EQUIPMENT LAYOUT PROVIDE BY MECHANICAL

CONTRACTOR.

J. CONDUIT FOR ROOF MOUNTED EQUIPMENT SHALL BE ROUTED IN

CEILING SPACE BELOW ROOF DECK UNO.

4' 8' 32'16'0

1/8" = 1'-0"

24'2'

SCALE: 1/8" = 1'-0"

ATTIC PLAN - ELECTRICAL

Revisions: Date:

Addendum #5 11/24/2020

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

ENLARGED 3RD FLOOR PLAN - TYPICAL

ISOLATION PATIENT ROOM - LIGHTING

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

ENLARGED 3RD FLOOR PLAN - TYPICAL

ISOLATION PATIENT ROOM - POWER /

SYSTEMS

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

ENLARGED 3RD FLOOR PLAN - TYPICAL

BARIATRIC PATIENT ROOM - POWER /

SYSTEMS

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

ENLARGED 3RD FLOOR PLAN - TYPICAL

BARIATRIC PATIENT ROOM - LIGHTING

Sheets
GI000 - COVER SHEET
AE104 - 3RD FLOOR ARCHITECTURAL PLAN
AI601 - FINISH SCHEDULE

File details come from the government source that posted it. Updated .