36C25018B0807-0005006.pdf

PDF 1 MB Posted

Attached to
Relocate PM&R to Basement of Building #2 Project 539-17-102
Solicitation number
36C25018B0807
Issued by

About this file

36C25018B0807 0005 Amend 5 New Drawing.pdf

View the file

Other files

File Type Posted
36C25018B0807-0005007.pdf PDF
36C25018B0807-0005004.docx DOCX document
36C25018B0807-0005005.pdf PDF
36C25018B0807-0004001.pdf PDF
36C25018B0807-0004000.docx DOCX document
36C25018B0807-0004002.pdf PDF
36C25018B0807-0003001.docx DOCX document
36C25018B0807-0002004.docx DOCX document
36C25018B0807-0002005.pdf PDF
36C25018B0807-014.docx DOCX document
36C25018B0807-0001001.pdf PDF
36C25018B0807-0001002.pdf PDF
36C25018B0807-0001000.docx DOCX document
36C25018B0807-013.docx DOCX document
36C25018B0807-011.pdf PDF
36C25018B0807-005.pdf PDF
36C25018B0807-004.pdf PDF
36C25018B0807-009.pdf PDF
36C25018B0807-012.pdf PDF
36C25018B0807-002.pdf PDF
36C25018B0807-006.docx DOCX document
36C25018B0807-003.pdf PDF
36C25018B0807-001.docx DOCX document
36C25018B0807-010.pdf PDF
36C25018B0807-007.docx DOCX document
36C25018B0807-008.pdf PDF
36C25018B0807-000.docx DOCX document
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REF.

UP

REF.

UP

D D

DDD

DDD

D D D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

DD

D

D

D D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D 46"

D

D

84" V

84" V

84" V

W P

SC

SC

SC

SC

SC

SC

SC

SC

SC

SC

AP

AP

AP

AP

AP

AP

AP

AP

AP

SC

SC

CR

CR

DM

DM

RX

RX

ES

ES

CC

CC

CC

CC

AP

D

T

T

T

T

D

D

D

D

D

D D

D

D

D

D

D

AP

F

D

D

D

D

D

D

D

D

D

D

D

D

D

84" V

W P

84" V

WP

P

DD

D

D

D

D

D

D

D

D

W P

F F

F

F

F F

F

F

D

F

F

FF

F

L

F

F

L

F

L

F F

F

F

F

F

L

T

T

84" V

M

F

F

L

L

FF

F

F

F

L

L

F

L

S R

S S

SR SR

WV

D

S

S

SC

S

S

SC S

SC

S

S

S

S

S

S

S

S

S

S

SC

S

S

S

S

S

S

D

TT

T

T

T

T

T

H

AC

R

ES

DM

DM

DM

DM

ES

CR

RX

RX

HA

HD

84" V

T

D

D

S

D

D

S R

SR

F

F

D

D

T

CC

SC

SC

SC

SC

SC

SC

SC

D

D F

D

T

T

T

T

D

F

HA

HA

HD

D

D

DA

T

A S

T A

T

IO

N X

-Y

DA

T

A S

T A

T

IO

N X

-Y

D

T

T

T

T

T

EX/WP

P

T

DA

T

A S

T A

T

IO

N X

-Y

AP

AP

XX"

P

D

DA

T

A S

T A

T

IO

N X

-Y

DA

T

A S

T A

T

IO

N X

-Y

0114-2

0107A

0114-1

0137 0114-1 S1.0

01180113

0112 0112A

0114-1

01190117A

0117B

0114-3

CY0

DEDUCT

ALTERNATE

#1

DEDUCT

ALTERNATE

#1

WP

DESK

MOUNTED

EX

EX

Z

I

Z

2-4"C.

2-4"C.

2-4"C.

REFER TO 1/4" PLANS AND ELEVATIONS,

SHEET E7, FOR ADDITIONAL INFORMATION.

12x4

12x4 x4

46"

46"

FACP

FUTURE A.H. UNIT

VERT.

C

EXIST

SIGNALS

CLOSET

EX

EX

EX

Z

Z

EXEX

EX

EX

EX

EX

EXEXEX EX

EX

EX

EX

Z

EX

EX

0107B

0107A

4 4

Drawing Title

Approved: Project Director

Location

Building Number

Project Title

Checked DrawnDate

Project No.

Drawing Number on e-ei gh th in ch o ne fo ot on e-qu ar te r i nc h on e fo ot th re e-ei gh th s in ch o ne fo ot on e-ha lf in ch o ne fo ot th re e-qu ar te rs in ch o ne fo ot on e in ch o ne fo ot on e an d on e-ha lf in ch es o ne fo ot th re e in ch es o ne fo ot

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

F E

D C

B A

CONSULTANTS:ARCHITECT/ENGINEERS:

Office of Construction and Facilities Management

F E

D C

B A

HEAPY PROJECT No.: 2016-05121 FIRM LICENSE No.: 01528

VA Project No. 539-17-102

Champlin Project No. 177-5668

/1

/2

:4

:0

A

M

RELOCATE SHORT TERM REHAB

COMMUNITY LIVING CENTER - RELOCATE

P.M.&R. TO BASEMENT OF BUILDING # 2

01/26/2018

BASEMENT FLOOR PLAN - SIGNALS

2-E3

CLMMSG

Cincinnati, Ohio

1/8" = 1'-0"2-E3

1 BASEMENT FLOOR PLAN - SIGNALS

NOTES

1 PROVIDE EMPTY OUTLET BOX FOR AV CABLING TO LOCAL PROJECTOR.

2 PROVIDE FIRE ALARM MONITORING MODULE FOR HOOD SUPPRESSION SYSTEM.

3 UNDER DEDUCT ALTERNATE #1, DELETE ALL WORK IN THIS AREA. PROVIDE FIRE

ALARM SPEAKER/STROBE IN EACH SHELL SPACE FOR ADEQUATE

COVERAGE.

1a: 3 SPEAKER/STROBES 1b: 1 SPEAKER/STROBE

2: 3 SPEAKER/STROBES

4 EXISTING DROP TO BE RE-CABLED WITH CATEGORY 6 CABLE.

BASEMENT SPACE SCHEDULE

Number Name

0-BASEMENT

001 Space

002 Space

0103 PT/OT CONDENSED STORAGE

0104 PT/OT SUPERVISOR OFFICE

0105 REHAB COORDINATOR OFFICE

0106 DISH MACHINE

0107A WAITING

0109 MAT / PRIVATE RM

0110 EXERCISE

0111 PT OFFICE

0112 RECEPTION / CHECK-IN

0112A OFFICE - PROGRAM SUPPORT REHAB

0113 TELEHEALTH / PMR EXAM/TREATMENT

0114-1 OCCUPATIONAL THERAPY-1

0114-2 OCCUPATIONAL THERAPY-2

0114-3 OCCUPATIONAL THERAPY-3

0115 OT OFFICE

0116 KILN ROOM

0117A ACTIVITIES FOR DAILY LIVING - KITCHEN

0117B ACTIVITIES FOR DAILY LIVING - BATH

0118 PMR EXAM/TREATMENT

0119 MEDIA CENTER

0120 PMR EXAM/TREATMENT

0121 HORTICULTURE THERAPY

0122 PMR EXAM/TREATMENT

0123 RECREATION GROUP ROOM

0124 RT OFFICE

0125 MECHANICAL (EXISTING)

0126 RT STORAGE

0129 PMR EXAM/TREATMENT

0130 PMR EXAM/TREATMENT

0131 PMR EXAM/TREATMENT

0132 STAFF TOILET

0133 HOUSEKEEPING CLOSET

0134 RCL OFFICE

0135 ELECTRICAL (EXISTING)

0136 RCL OFFICE

0137 CLEAN LINEN

0138 PATIENT CARE STORAGE

0139 SOILED LINEN

0140 PATIENT MEN'S

0141 PATIENT WOMEN'S

CY0 COURTYARD (EXISTING)

S1.0 STAIR (EXISTING)

N

GENERAL NOTES

A ALL NEW VOICE/DATA TO BE CABLED TO DATA ROOM 002.

B REFER TO ARCHITECTURAL PHASING PLAN AND INCLUDE ALL WORK NECESSARY TO

ACCOMMODATE PHASING.

C REFER TO ARCHITECTURAL DRAWINGS FOR RATED WALL LOCATIONS.

D INCLUDE ALL WORK NECESSARY TO ACCOMMODATE PHASING. REFER TO

ARCHITECTURAL DRAWINGS AND GENERAL REQUIREMENTS SECTION 01 00 00.

E COORDINATE ALL NEW FIRE ALARM/FIRE SUPPRESSION ZONES WITH COTR.

F REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATIONS OF DEVICES

MOUNTED ABOVE OR BELOW CASEWORK, FURNITURE, LAVATORIES, ETC.

G REQUIRED SHUT-DOWNS OF THE SMOKE DETECTION SYSTEM AND FIRE

SUPPRESSION SPRINKLER SYSTEM SHALL NOT OCCUR CONCURRENTLY AND SHALL

COMPLY WITH THE JOINT COMMISSION ON ACCREDITATION OF HEALTHCARE

ORGANIZATIONS (JCAHO) INTERIM LIFE SAFETY MEASURES (ILSM). COORDINATION

BETWEEN COTR AND ALL TRADES SHALL BE REQUIRED BEFORE SHUT-DOWN OF

THE SMOKE DETECTION SYSTEM OR FIRE SUPPRESSION SPRINKLER SYSTEM.

H PROVIDE ALL NEW FIRE ALARM BOOSTER PANELS, TRANSPONDER PANELS,

FIBER/COPPER BACKBONE, 120V POWER CIRCUITS, CONDUIT, ETC. AS REQUIRED

TO SERVE NEW DEVICES. COORDINATE ALL NEW EQUIPMENT WITH

MANUFACTURER.

I NURSE CALL SYSTEM SHALL BE SOLE SOURCED TO NEWTECH SYSTEMS. CONTACT TODD

SEIPLE (PHONE #: 614-350-8301)

Revisions Date

1 BID DOCUMENTS 01.26.18

2 BULLETIN #1 09.12.18

Sheets
2-E3 - BASEMENT FLOOR PLAN - SIGNALS

File details come from the government source that posted it.