S06 - A0005 - Attachment 8 - AD141 - DEMOLITON REFLECTED CEILING PLAN - Add 1 (1).pdf
PDF 1 MB Posted
- Solicitation number
- 36C24921R0108
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OS
OS
OSOS
MM
MM
O
N
M
L
K
K.1
7 8 9 10 11 12 13 14 16
P
LOGISTICS
CLEAN SUPPLY
STORAGE
A-019b
INSTRUMENT
PREP ROOM
B-039
DECONTAMINATION
ROOM
A-018
MATERIAL
MANAGEMENT
STORAGE
A-019
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
SPD OFFICE
B-039a
WOMEN'S
SHOWER
B-041
MEN'S SHOWER
B-042
BREAK ROOM
B-040
VESTIBULE
B039
HOLDING
B-043
CART WASH
A-018b
EQUIP
A-019a
BREAKDOWN
AREA
A023C
OFFICE
A023B
WAREHOUSE
A023
OFFICE
A023DINCOMING
INSPECTION
A023E
TYP.
TYP.
/4
TYP.
1 1010
PHASE II
G E N E R A L N O T E S
2' X 4' LIGHT FIXTURE TO BE REMOVED.
ACCESS PANEL
GYPSUM BOARD CEILING
ACOUSTIC TILE CEILING
HVAC SUPPLY
EXIT SIGN
HVAC RETURN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% BID DOCUMENTS
ROBLEY
REX
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
603-20-201
800 Zorn Ave., Louisville, KY
REPLACE SPS AIR HANDLER
ARCHITECT/ENGINEER OF RECORDCONSULTANT
C U s e rs
\c ra ig \D o c u m e n ts
\F F
E
L o u is v ill e
R e p la c e S
P S
A H
U c ra ig .l ie g ib e l@ ff e -s e rv
.c o m
.r v t
/2
/2
:4
:4
A
M
AD141
DEMOLITON REFLECTED CEILING
PLAN
06/29/2021 PQ DB
SCALE: 1/4" = 1'-0"
BASEMENT - DEMOLITION REFLECTED CEILING PLAN
D E M O L I T I O N N O T E S
1 REMOVE EXISTING GYPSUM BOARD CEILING AND ASSOCIATED FRAMING MEMBERS.
2 NO WORK IN THIS AREA. PROTECT AREAS DURING ALL PHASES OF CONSTRUCTION.
3 REMOVE EXISTING ACT CEILING AND ASSOCIATED CONSTRUCTION.
4 REMOVE EXISTING LIGHT FIXTURE.
5 EXISTING ACCESS PANEL TO BE REMOVED.
6 REMOVE EXISTING GYPSUM BOARD CEILING AS REQUIRED FOR INSTALLATION OF NEW SUPPLY
AND RETURN DIFFUSERS.
7 CEILING EXPOSED TO STRUCTURE - NO WORK NEEDED
8 REMOVE EXISTING SUPPORT POLES, ESCUTCHEON PLATES, AND ELECTRICAL OUTLET,
9 EXISTING SANITATION EQUIPMENT TO REMAIN.
10 REMOVE EXISTING SLOPED METAL CEILING.
11 PROVIDE PREFABRICATED TEMPORARY CONSTRUCTION SMOKE PARTITION WALL TO
TERMINATE AT EXISTING CEILING - EXISTING CEILING SHALL REMAIN - SEE ICRA REQUIREMENTS IN SPECIFICATIONS FOR INSTRUCTIONS AT PARTITION AND DOOR - REMOVE AT COMPLETION OF
WORK - IF ADJACENT SURFACES ARE DISTURBED, CONTRACTOR SHALL PATCH AND REPAIR TO
MATCH EXISTING.
RCP LEGEND
A. PROTECT / REPAIR EXISTING WALLS DURING ENTIRETY OF CONSTRUCTION
B. SEE ELECTRICAL DRAWINGS FOR CEILING-MOUNTED ELECTRICAL ITEMS
N.T.S.Scale:
KEY PLAN
1616637 Exp:12/31/2021
PATRICK R. QUINN
Revisions: Date:
100% BID DOCUMENTS 07/13/2021
ADDENDUM #1 09/20/20211
| Sheets |
| AD141 - DEMOLITON REFLECTED CEILING PLAN |
| AE101 - BASEMENT FLOOR PLAN |
| AE141 - REFLECTED CEILING PLAN |
| AE501 - PLAN DETAILS, DOOR SCHEDULE, AND FINISH LEGEND |
File details come from the government source that posted it. Updated .