P
CH-1
EEQD - 1,3,5
SB-1 - 1
AH-43-S
EEQD
DEDUCT ALTERNATE - A
D E D U C T
A L T E R N A T E A
DEDUCT ALTERNATE - A
D E D U C T
A L T E R N A T E A
AP
SJ
AP
SJ
AP
AP
6 6
7 7
LOGISTICS
CLEAN SUPPLY
STORAGE
A-019b
MATERIAL
MANAGEMENT
STORAGE
A-019
DECONTAMINATION
ROOM
A-018
INSTRUMENT
PREP ROOM
B-039
BREAKDOWN
AREA
A023C
WAREHOUSE
A023
SPD OFFICE
B-039a
BREAK ROOM
B-040
STERILIZERS
B-039c
OFFICE
A023D
INCOMING
INSPECTION
A023E
OFFICE
A023B
CR
EL
SOFTWARE HOUSE
CONTROLLER IN
CEILING
PHASE II
ATS-1
PANEL EEQ
PANEL EEQA
PANEL ELP
ATS-4
PANEL EEQB
ATS-7
N1TIP-1
N1TIP-2
EEQ1SBATS-3
ATS-2
EMS
PANEL NMS
STREET
LIGHTS PANEL
ST
LIGHTS
PANEL ELS
208/120V SB-2
480/277V SB-1
EP 480/1
EP 480
ATS-A
EMS 480V
ATS-B ATS-C
ATS-9
N1TP2
EEQ1SB2
EEQC
SECTION 3
O
N
M
L
K
K.1
6 7 8 9 10 11 12 13 14 16
P
CHWP-2
CHWP-1
HRCP-1
NITIP-2 - 26,28
VFD CHWP-1
VFD CHWP-2
TEMPERATURE
CONTROL PANEL
(EEQ1SB) - (9)
EEQD - 7,9,11
EEQD - 8,10,12
EEQD - 7,9,11 EEQD - 8,10,12
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% BID DOCUMENTS
ROBLEY
REX
VA MEDICAL
CENTER
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMP
321 4 5 6 7 8 9 10
603-20-201
800 Zorn Ave., Louisville, KY
REPLACE SPS AIR HANDLER
ARCHITECT/ENGINEER OF RECORDCONSULTANT
C
U s e rs \i s s a c \D o c u m e n ts
\F F
E
L o u is v ill e
R e p la c e S
P S
A H
U is s a c h a r.
a n d e rs o n ff e
-s e rv .c o m
.r v t
/2
/2
:2
:2
A
M
EP101
BASEMENT & SUB-BASEMENT
POWER AND TECHNOLOGY PLAN
06/29/2021 JB HT
SCALE: 1/8" = 1'-0"
BASEMENT POWER PLAN
SCALE: 1/8" = 1'-0"
SUB-BASEMENT SWITCHBOARD ROOM
K E Y N O T E S
1 LOCATION OF NEW ATS-9. PROVIDE UNISTRUT SUPPORT FRAME.
2 PROVIDE NEW 200A CIRCUIT BREAKERS IN PANELS EMS-480V (SQUARE D,
I-LINE) CKT #17, 19, 21 & SB-1 (EATON) CKT. #13. RATED 65KA.
3 CONNECT RECEPTACLE TO LOCAL CIRCUIT.
4 MOUNT ON WALL BELOW. REMOVE OLD CONTROL BOX.
5 CONTRACTOR TO FIELD-VERIFY CKT IN SB-1 FOR VFD BEING DEMOLISHED
AND REUSE TO POWER NEW VFDS FOR CHWP-1 AND CHWP-2. PROVIDE
UNISTRUT SUPPORT FRAME TO MOUNT VFDS FOR CHWP-1 AND CHWP-2.
6 INSTALL NEW DUPLEX RECEPTACLE IN CEILING IN SAME LOCATION AS
DEMOLISHED RECEPTACLE. CIRCUIT TO EXISTING CIRCUIT MAINTAINED
DURING DEMOLITION.
7 RE-INSTALL EXISTING NURSE CALL STAFF LOCATORS IN SAME LOCATION.
8 RE-INSTALL EXISTING WIRELESS ACCESS POINTS IN SAME LOCATION.
9 RE-INSTALL EXISTING SPEAKER IN SAME LOCATION.
10 FIRE ALARM CONTROL PANEL IN CEILING. CONNECT TO FIRE ALARM INPUT
ADDRESSABLE MODULE IN CEILING. PROVIDE CEILING ACCESS PANEL FOR
FIRE ALARM CONTROL PANEL.
SCALE: 1/8" = 1'-0"
SUB=BASEMENT POWER PLAN
Revisions: Date:
100% BID DOCUMENTS 06/29/2021
ADDENDUM #1 09/20/2021
| Sheets |
| EP101 - BASEMENT & SUB-BASEMENT POWER AND TECHNOLOGY PLAN |