This document provides the results of a lead based paint survey conducted at a VA Medical Center building. The survey identified various components at the building that tested positive for lead based paint, including wooden baseboards, doors, windows, walls and other components on the exterior of the building as well as in the basement, first and second floors. The report provides the approximate linear footage and locations of affected components. This information will support planning for the removal and abatement of lead based paint at the specified building.
A related federal contract opportunity notice seeks proposals for a construction project to correct environment and condition deficiencies at the VA Medical Center's Administration Building 20. The project scope includes modifications to existing areas, demolition, and replacement of finish materials. The requirement has an estimated value between $1-5 million. Proposals are due by November 20, 2021. This is a 100% SDVOSB set-aside to be awarded under FAR Part 14 sealed bidding procedures. Offerors must be verified in CVE and registered in SAM.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VA Medical Center Lead Based Paint Survey Results Page 1 of 5
4.6 Building 20
E. Roberts Alley & Associates, Inc. U.S. Dept of Veterans Affairs December 2005 Project No. 2005-0731 VA Contract GS-10F-0165R
VA Project No. 621-05-115
Introduction:
Building 20 houses the Human Resources offices. It is constructed on a partial basement and crawlspace foundation. It is a two-story rectangular building with a brick exterior with wood doors, windows, and soffitt. It was originally a jail. The basement has brick walls and a concrete floor. A small room on the east side of the basement is constructed of concrete block.
The first and second floors are constructed of wood. The interior of the building is predominantly plaster, although there have been some walls added which are finished with gypsum wallboard. Many of the first floor’s walls are finished in a white texture material, both on plaster walls and on gypsum walls. Suspended ceiling tiles have also been installed on both the first and second floor.
Summary of results:
1. Exterior: All wooden components tested positive for lead-based paint.
2. Basement: Three walls and some wood components of the stairs tested positive for lead-based paint.
3. First floor: Many wooden components and one wall tested positive for lead-based paint.
4. Second floor: Many wooden components and several walls tested positive for lead-based paint.
Within Building 20, the linear feet of each component containing lead based paint were calculated from the CAD drawings. The approximate quantities are listed as follows:
Component Approximate Quantity, in linear feet (lf) Baseboards 205 lf Stairs/Railings* 1 Staircase, Basement floor Inner Walls 145 lf Windows 37 lf Doors 24 lf
*Linear footage could not be computed for wood components on staircases; quantities are designated for number of staircases, by floor.
Specific locations are given in the table below.
Testing data is located in Appendix A, Section A.6
VA Medical Center Lead Based Paint Survey Results Page 2 of 5
E. Roberts Alley & Associates, Inc. U.S. Dept of Veterans Affairs December 2005 Project No. 2005-0731 VA Contract GS-10F-0165R
VA Project No. 621-05-115
LEAD BASED PAINT COMPONENTS:
ROOM
EQUIVALENT1 SIDE DESIGNATION2 COMPONENT3 SUBSTRATE4,5
EXTERIOR
Rafters Wood
Roof Boards Wood Door Casing Wood
Skylight over Door Wood Basement Door Wood
Door Casing Wood Window – Left Side Wood
Window Casing Wood Window – Left Side Wood
Window Casing Wood Window – Right Side Wood
Window Casing Wood Window – Right Side Wood
Wall A
Window Casing Wood Rafters Rafters5
Roof Boards Roof Boards5 Window (3) Wood5 Wall B
Window Casing (3) Wood5 Rafters Wood
Roof Boards Wood Window Wood
Window Casing Wood Window Wood
Window Casing Wood Window Wood
Window Casing Wood Window (3) Wood5
Wall C
Window Casing (3) Wood5 Rafters Rafters5
Roof Boards Roof Board5 Door Wood
Door Casing Wood Window Wood
Window Casing Wood Window (2) Wood5
Exterior
Wall D
Window Casing (2) Wood5
VA Medical Center Lead Based Paint Survey Results Page 3 of 5
E. Roberts Alley & Associates, Inc. U.S. Dept of Veterans Affairs December 2005 Project No. 2005-0731 VA Contract GS-10F-0165R
VA Project No. 621-05-115
ROOM
EQUIVALENT1 SIDE DESIGNATION2 COMPONENT3 SUBSTRATE4,5
BASEMENT
Right Stringer Wood Stairway Left Stringer Wood
Wall A Wall Plaster Wall B Wall Plaster
Basement
Wall C Wall Plaster
FIRST FLOOR
Door Casing Wood Wall A Baseboard Wood5 Wall B Baseboard Wood5 Wall C Baseboard Wood5
Entryway
Wall D Baseboard Wood Window Wood Room 101 Wall A Window Casing Wood
Wall A Baseboard Wood Wall B Baseboard Wood5
Baseboard Wood5 Wall C Door Casing Wood Room 101A
Wall D Baseboard Wood5 Window Casing Wood Wall A Baseboard Wood
Wall B Baseboard Wood5 Wall C Baseboard Wood5
Room 103
Wall D Baseboard Wood5 Wall A Baseboard Wood5 Wall B Baseboard Wood5 Wall C Baseboard Wood Room 105
Wall D Baseboard Wood5 Wall Plaster
Window Wood Room 106 Wall B Window Casing Wood
Window WoodRoom 107 Wall A Window Casing Wood Room 108 Wall C Door Casing Wood Room 109 Wall C Door Casing Wood Room 110 Wall C Window Casing Wood
Window WoodWall C Window Casing Wood Room 111 Wall D Door Casing Wood
VA Medical Center Lead Based Paint Survey Results Page 4 of 5
E. Roberts Alley & Associates, Inc. U.S. Dept of Veterans Affairs December 2005 Project No. 2005-0731 VA Contract GS-10F-0165R
VA Project No. 621-05-115
ROOM
EQUIVALENT1 SIDE DESIGNATION2 COMPONENT3 SUBSTRATE4,5
Wall A Door Casing Wood Wall C Trim Wood Room 113 Wall D Window Casing Wood Wall A Door Casing Wood
Door Casing Wood Window WoodWall B
Window Casing Wood Window Wood
Room 112
Wall C Window Casing Wood Baseboard Wood Window WoodWall A
Window Casing Wood Room 117
Wall D Door Casing Wood Window WoodRoom 103 Wall A Window Casing Wood
SECOND FLOOR
Baseboard WoodWall A Window Casing` Wood
Wall B Baseboard Wood5 Wall C Baseboard Wood5
Entry Hallway
Wall D Baseboard Wood5 Main Hallway Wall C Wall Plaster
Janitorial Room Wall D Window Casing Wood Wall PlasterRoom 202 Wall A Window Casing Wood
Room 204 Wall C Upper Wall Plaster Wall C Upper Wall Plaster Room 206 Wall D Upper Wall Plaster
206A Wall A Door Wood Wall A Door Wood Wall B Chair Rail Wood 206B Wall D Chair Rail Wood Wall A Door Casing Wood Room 208 Wall C Wall Drywall
Room 209 Wall C Door Wood Room 210 Wall D Wall Drywall Room 212 Wall A Door Wood
VA Medical Center Lead Based Paint Survey Results Page 5 of 5
E. Roberts Alley & Associates, Inc. U.S. Dept of Veterans Affairs December 2005 Project No. 2005-0731 VA Contract GS-10F-0165R
VA Project No. 621-05-115
ROOM
EQUIVALENT1 SIDE DESIGNATION2 COMPONENT3 SUBSTRATE4,5
Wall A Baseboard Wood5 Wall B Baseboard Wood5 Wall C Baseboard Wood Room 213
Wall D Baseboard Wood5
1) Room equivalent is an identifiable part of a building, such as a room, exterior, foyer, staircase, hallway, etc. All four exterior sides of a building are considered as a single room equivalent if the paint history appears to be similar.
2) Side “A” is the side or wall facing the front of the building. The other sides, “B”,”C”, and “D”, are designated in a clockwise pattern.
3) Component is the particular material that has been painted, such as windows, doors, trim columns, crown molding, etc.
4) Substrate is the material underneath the paint. There are six common types of substrates: brick, concrete, drywall, metal, plaster, or wood.
5) These components are presumed positive. Similar building components with identical substrates that exhibit similar painting history can be assumed to be lead based paint provided that sufficient testing (usually at least five room equivalents) has been performed on other locations of this same component within the same building.
File details come from the government source that posted it. Updated .