This presolicitation notice announces a planned small business set-aside procurement for construction services. The Department of Veterans Affairs intends to award a firm-fixed-price contract valued between $1 million and $5 million to renovate administration building 20 at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. Work includes office space for police staff, conference rooms, locker rooms, and finish upgrades. The solicitation is expected to post on October 20, 2021 and close on November 20, 2021. Only Service-Disabled Veteran Owned Small Businesses listed in the CVE database and SAM will be considered. Questions must be submitted in writing by the specified date.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5 6 7 8 9 10 11 12 13 144 15
NEW HANDRAIL TO BE INSTALLED
TO MATCH EXISTING RAILINGS AT
UPPER LEVELS (AT WALL BEYOND)
NEW HANDRAIL AND BALUSTERS TO BE FABRICATED
AND INSTALLED TO ACHIEVE AN OVERALL RAILING
HEIGHT OF 42" A.F.F (MATCH IN KIND TO EXISTING AT
UPPER FLOOR)1
5 6 7 8 9 10 11 12 13 144 15
E4
A-401
EXISTING NEWEL POSTS TO BE
REMOVED, RESTORED AND
REUSED
EXISTING RAILING REMOVED
AND DISPOSED
EXISTING WOOD STAIRS TO BE
REPAIRED TO MATCH EXISTING.
A .F
.F
1' - 0"
NEW HANDRAIL TO BE INSTALLED
TO MATCH EXISTING RAILINGS AT
UPPERLEVELS (AT WALL BEYOND)
EXISTING WOOD STAIRS TO
BE
REPAIRED TO MATCH
EXISTING.
42" A.F.F. 42" A.F.F.
NEW BALUSTERS TO BE FABRICATED AND
INSTALLED TO ACHIEVE AN OVERALL
RAILING HEIGHT OF 42" A.F.F (MATCH IN
KIND TO EXISTING AT UPPER FLOOR)
NEW HANDRAIL TO BE FABRICATED AND INSTALLED
TO ACHIEVE AN OVERALL RAILING HEIGHT OF 42"
A.F.F (MATCH IN KIND TO EXISTING AT UPPER
FLOOR)
EQ
EQ
1' - 0"
NEW HANDRAIL
(TO MATCH UPPER
FLOORS)
NEW BALUSTER
NEW BALUSTER TO
BE DOVETAILED INTO
TREAD
HANDRAIL HEIGHT
42" TO A.F.F.
V.I.F.
EXISTING TREAD
RETURN
EXISTING FACE
STRINGER
1' - 0"
42" A.F.F.
NEW HANDRAIL TO BE INSTALLED TO
MATCH EXISTING RAILINGS AT UPPER
LEVELS (AT WALL BEYOND)
NOTES:
1. NEW REPLACEMENT WOOD ELEMENTS TO
MATCH ORIGINAL TYPE, COLOR, SHAPE/ PROFILE,
AND SIZE.
2. ALL WOOD ELEMENTS DEEMED DAMAGED TO BE
REPLACED AND ASSOCIATED ACCESSORIES
REPLACED.
3. VERIFY MATCH OF NEW FINISH MATERIALS TO
EXISTING IN COLOR TEXTURE, THICKNESS, CUT,
ETC. TO THE STANDARD OF PRIOR TO
INSTALLATIONS.
4. SURFACES SHALL BE PREPARED TO RECEIVE
NEW SCHEDULED FINISHES BY GRINDING,
SCRAPING, FILLING, PATCHING, LEVELING, ETC.
AS REQUIRED (REFER TO INTERIOR DESIGN
DOCUMENTS).
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-401
ENLARGED PLAN, ELEVATION AND
SECTION OF INTERIOR STAIRS
HMPRKP
SCALE: 3/4" = 1'-0"B1
PLAN OF EXISTING STAIR (BASEMENT TO 1ST FLOOR)
SCALE: 3/4" = 1'-0"D1
PLAN OF NEW STAIR (BASEMENT TO 1ST FLOOR)
SCALE: 3/4" = 1'-0"B4
ELEVATION OF EXISTING STAIR ( (BASEMENT TO 1ST FLOOR)
SCALE: 3/4" = 1'-0"F1
ELEVATION OF NEW STAIR (BASEMENT TO 1ST FLOOR )
SCALE: 3/4" = 1'-0"E4
SECTION OF NEW STAIR (BASEMENT TO 1ST FLOOR )
SCALE: 1 1/2" = 1'-0"B9
SECTION OF NEW HANDRAIL
SCALE: 3/4" = 1'-0"E9
ELEVATION AT NEW STAIR
1. FIELD VERIFY ALL DIMENSIONS
2. CATALOGUE, REMOVE, STORE REFURBISH AND REUSE THE EXISTING STAIR ELEMENTS I.E.,TOP HANDRAIL AND NEWEL POSTS AT INTERIOR STAIRS.
3. PROVIDE BLOCKING, FRAMING AND SHIMS AS NECESSARY TO INSTALL AND RESTORE STAIRS.
4. EXISTING ARCHITECTURAL ELEMENTS SHOULD BE USED AS TEMPLATES FOR NEW WORK AND FOR RESTORATION OF ELEMENTS. ALL NEW AND RESTORATION RELATED WORK SHOULD MATCH PROFILES OF EXISTING MATERIALS UNLESS OTHERWISE NOTED.
GENERAL NOTES
SCALE: = 1'-0"3/4"
0 1 2 31
SCALE: = 1'-0"1 1/2"
01 1
REVISIONS DATE
6 7 8 9 10 11 12 13 14 15 16
EXISTING RAILING
HEIGHT 32" - 36"
EXISTING RAILING
HEIGHT 32" - 36"
EXISTING TOP RAIL TO BE REMOVED,
RESTORED AND REUSED
EXISTING TOP RAIL TO BE
REMOVED AND REUSED
EXISTING RAIL (AT WALL
BEYOND) TO BE REMOVED
AND REUSED
EXISTING BALUSTERS OF THE BALUSTRADE
TO BE REMOVED AND DISCARDED
EXISTING NEWEL POSTS TO BE REMOVED,
MODIFIED, RESTORED AND REUSED
EXISTING NEWEL POSTS TO BE REMOVED,
MODIFIED AND REUSED
EXISTING CARPET TO BE
REMOVED AND DISPOSED
EXISTING BALUSTERS OF THE BALUSTRADE
TO BE REMOVED AND DISPOSED
EXISTING RAIL TO BE REMOVED,
RESTORED AND REUSED
OUTER STRINGER TO BE REMOVED,
RESTORED AND REUSED
WALL STRINGER TO BE REMOVED,
RESTORED AND REUSED
x 2 x x
HANDRAIL HEIGHT
42" A.F.F.
V.I.F.
HANDRAIL HEIGHT
42" A.F.F.
V.I.F.
NEW BALUSTRADES TO BE FABRICATED AND
INSTALLED TO ACHIEVE AN OVERALL RAILING
HEIGHT OF 42" A.F.F (MATCH IN KIND)
NEW BALUSTERS TO BE FABRICATED
AND INSTALLED TO ACHIEVE AN
OVERALL RAILING HEIGHT OF 42"
A.F.F (MATCH IN KIND)
NEW BALUSTERS TO BE FABRICATED AND
INSTALLED TO ACHIEVE AN OVERALL
RAILING HEIGHT OF 42" A.F.F
EQ EQ
HANDRAIL HEIGHT
42" AFF
V.I.F.
C. ELEVATION OF RAILINGS AT FIRST FLOORB. ELEVATION AND SECTION OF RAILINGS FROM SECOND FLOOR TO FIRST FLOOR
A. ELEVATION OF RAILINGS AT SECOND FLOOR
NOTES
1. ALL NEW INSTALLATIONS, REPAIR MATERIAL AND FINISHES SHALL
MATCH EXISTING.
2. PERFORM PREPARATION AND CLEANING PROCEDURES IN
ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FOR EACH
CONDITION.
3. PATCH AND REPAIR ALL EXISTING SURFACES FOR THE
INSTALLATION OF NEW WORK AND/ OR UTILITIES, AS REQUIRED TO
MATCH ADJACENT SURFACES AND/ OR TO RECEIVE NEW
SCHEDULED FINISHES.
x x x
FIRST FLOOR SECOND FLOOR SECOND FLOOR (HALF)
NOTE: ALL NEWEL POSTS
ARE TO BE REMOVED,
RESTORED AND REUSED.
MODIFY THE BASE WITH THE
RESULT THAT THE OVERALL
HEIGHT OF THE EXISTING
RAILINGS ARE RAISED TO 42"
ABOVE FINISHED FLOOR
(A.F.F.). X REPRESENTS THE
MODIFIED HEIGHT
ADJUSTMENT TO BE MADE
TO EACH NEWEL POST BASE.
EXISTING RAILING
HEIGHT 32" - 36"
EXISTING RAILING TO BE
REMOVED AND REUSED
EXISTING CARPET TO BE
REMOVED AND DISPOSED
EXISTING WOOD STAIRS TO BE
REPAIRED TO MATCH EXISTING.
EXISTING WALL STRINGER
TO BE REMOVED, RESTORED
AND REUSED.
2 1_
2 1_
D. HANDRAIL PROFILE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-402
ENLARGED PLAN, ELEVATION AND
SECTION OF INTERIOR STAIRS
HMPRKP
SCALE: 3/4" = 1'-0"B1
PLAN OF EXISTING STAIR (1ST FLOOR TO 2ND FLOOR)
SCALE: N.T.S.F1
ELEVATION OF EXISTING STAIR (1ST FLOOR TO 2ND FLOOR)
SCALE: 3/4" = 1'-0"F5
SECTION AND ELEVATION OF NEW STAIR (1ST TO 2ND FLOOR)
SCALE: N.T.S.B5
ELEVATIONS OF NEW NEWEL POSTS AT NEW STAIR
SCALE: N.T.S.B8
SECTION OF EXISTING STAIR (1ST TO 2ND FLOOR)
1. FIELD VERIFY ALL DIMENSIONS
2. CATALOGUE, REMOVE, STORE REFURBISH AND REUSE THE EXISTING STAIR ELEMENTS I.E.,TOP HANDRAIL AND NEWEL POSTS.
3. PROVIDE BLOCKING, FRAMING AND SHIMS AS NECESSARY TO INSTALL AND RESTORE STAIRS.
4. EXISTING ARCHITECTURAL ELEMENTS SHOULD BE USED AS TEMPLATES FOR NEW WORK AND FOR RESTORATION OF ELEMENTS. ALL NEW AND RESTORATION
RELATED WORK SHOULD MATCH PROFILES OF EXISTING MATERIALS UNLESS OTHERWISE NOTED.
GENERAL NOTES
EXTERIOR FACADE
EXTENTS
ROOF EDGE
24' - 3"
12' - 7"
15' - 3"
32' - 6"
35' - 10"
NOTE: ALL DESIGNS SHOWN HERE ARE SUBJECT TO CHANGE PENDING FIELD VERIFICATION OF EXISTING CONDITIONS.
MEMORIAL AVENUE
V E
T E
R A
N S
S T
R E
E T
N
5' - 3"
6' - 0"
4' - 0"
6' - 0"
5' - 3"
4' TYPICAL
OPENING
12" 6' - 0" 6' - 0" 6' - 0"
INTERIOR
FIRST FLOOR
22" ∅ X 3' - 0"
DEEP, TYP X4
16" ∅ X 3' - 0"
DEEP, TYP X4
22" ∅ X 3' - 0"
DEEP, TYP X4
16" ∅ X 3' - 0"
DEEP, TYP X 2
16" ∅ X 3' - 0"
DEEP, TYP X 2
22" ∅ X 3' - 0"
DEEP, TYP X 4
DN
5' -3"
5' -3"
6' - 0" 12' - 3"
2' - 0"
4' TYPICAL
OPENING
5' - 3"
6' - 0"
4' - 0"
6' - 0"
5' - 3"
INTERIOR
SCEOND FLOOR
3' - 7"
MINIMUM
3' - 7"
MINIMUM
3' - 0"
1' - 0"
TOP RAIL
TOP SECOND RAIL
26' - 6"
32' - 6" 2' - 0"
4' TYPICAL
OPENING
12 EQUAL
RISERS AT
7' - 3"
13 EQUAL
RISERS AT
7' - 10"
12 EQUAL
RISERS AT
7' - 3"
13 EQUAL
RISERS AT
7' - 10"
1' - 0"6' - 0"6' - 0"6' - 0"5' - 3"
24' - 3"
36"
HANDRAIL
42"
GUARDRAIL
63 - 7/8"
55 - 5/8" DECK WIDTH
EXTRUDED
ALUMINUM NON- SLIP
DECKING
48" CLEARANCE
2 1/4"
59 - 7/8"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-403
ENLARGED PLAN, EXTERIOR STAIR, &
ADA RAMP DETAILS
HMPRKP
SCALE: = 1'-0"3/4"
0 1 2 31
SCALE: = 1'-0"
0 4 84
1/4"
SCALE: N.T.S.
C1
PLAN OF THE EXTERIOR EGRESS STAIR AND ADA RAMP
SCALE: 1/4" = 1'-0"
C5
ENLARGED FIRST FLOOR PLAN OF THE EGRESS ADA RAMP AND STAIR
SCALE: 1/4" = 1'-0"
C8
ENLARGED SECOND FLOOR PLAN OF THE EGRESS ADA RAMP AND STAIR
SCALE: 1/4" = 1'-0"
F1
EAST ELEVATION OF EGRESS STAIR AND ADA RAMP
SCALE: 1/4" = 1'-0"
F5
EGRESS STAIR ELEVATION II
SCALE: 3/4" = 1'-0"
F8
TYPICAL RAMP SECTION
PRE-MANUFACTURED EGRESS STAIR AD ADA RAMP
NOTES:
1. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO
FABRICATION
2. INSTALLATION TO BE COMPLETED IN
ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS.
- IBC AND OSHA COMPLIANT
- HEAVY DUTY ALUMINIUM CONSTRUCTION
- EXTRA WIDE DIAMOND PLATE TREADS
- RAILING WITH BALUSTERS
- POWDER COATED FINISH
NOTES:
1. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION
2. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS.
MECHANICAL
ROOM
HOUSE
KEEPING
A-404
F3
A-404
E1
A-404
F1
LOUVER TO BE REMOVED.
SEE MECHANICAL DRAWINGS.
LOCATION OF ACCESS
LADDER TO BE
INSTALL AND SECURE
TO THE WALL.
PROVIDE 24"x24"
ACCESS PANEL AT
ATTIC ENTRANCE.
F .F
T
O T
O P
O F
D E
C K
IN
G
(V E
R
IF
Y
(B
ATTIC
FLOOR
(V E
R
IF
Y
C
WALL
BRACKET
TYP. ALUM.
SERRATED
RUNGS
SAFETY
CAP
E Q
U A
L S
P A
C E
S A
T
O .C
(V E
R
IF
Y
O V
E R
A L L L
A D
D E
R H
E
IG
H T
V A
R
IE
S
FLOOR BRACKET
(A
LEGEND:
(A) LADDER HEIGHT
(B) F.F. TO TOP OF DECKING
(C) ROOF HATCH BASE HEIGHT
(E) LADDER WIDTH
CONTRACTOR TO VERIFY ALL DIMENSIONSIN THE FIELD
FRONT ELEVATION SIDE ELEVATION
(S P
E C
IF
Y
V A
R
IE
S
C L E
A R
ALTERNATE
BRACKET
ALUM.
TUBULAR
ALUM.
LADDER
E
7" STANDARD
ALTERNATE OFF FLOOR SUPPORT
CL
LADDER
WALL BRACKET TO
CONNECTION FROM
ALUMINUM
ANCHOR BOLTS
HOLES FOR
WALL BRACKETS
AT 10' - 0" O.C. MAX.
E
M
IN
IM
U
M
LADDER STEP
ALUMINUM
TUBULAR
LADDER
LADDER DETAILS
REMOVE MECHANICAL LOUVER AND INSTALL A NEW WINDOW. REFER TO
MECHANICAL DRAWINGS. SEE WINDOW SCHEDULE
INSTALL A NEW ACCESS LADDER AND SECURE TO THE EXISTING WALL
OPENING IN CEILING ABOVE. PROVIDE 24" X 24" ACCESS PANEL.
KEYNOTES:
1. COORDINATE WITH M/E/P DRAWINGS FOR ADDITIONAL WORK AS REQUIRED TO
ACCOMODATE NEW CONSTRUCTION OR UTILITIES ON THESE FLOORS OR RELATED
ADJACENT FLOORS. PATCH/REPAIR BY EACH RESPECTIVE DISCIPLINE. COORDINATE WITH
OTHER DISCIPLINES. HOLES/ PENETRATIONS IN RATED WALLS CREATED WHEN DEMOLITION
OCCURS ARE TO BE FILLED TO MATCH THE EXISTING RATED CONDITION OR BETTER.
2. VERIFY ALL CONDITIONS AND DIMENSIONS IN THE FIELD AND ANY DISCREPENCIES SHALL
BE REPORTED TO THE ARCHITECT BEFORE PROCEEDING WITH ANY WORK
3. PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY DEMOLITION AND/ OR
INSTALLATION OF NEW WORK AND/ OR UTILITIES, AS REQUIRED TO MATCH ADJACENT
SURFACES AND/ OR TO RECEIVE NEW SCHEDULED FINISHES.
4. CONTRACTOR TO MAINTAIN/REPAIR RATING OF EXISTING PARTITIONS AS AFFECTED BY
DEMOLITION/NEW CONSTRUCTION, TYPICAL THROUGHOUT.
5. PROVIDE BLOCKING AS REQUIRED FOR ALL CABINETS, EQUIPMENT,HANDRAILS, TOILET
ACCESSORIES INDICATED ON EQUIPMENT PLANS AND FINISH PLANS.
GENERAL NOTES:
ATTIC INSULATION
WOOD TRUSS FRAMING
SHEATH INTERIOR OF
ATTIC ACCESS TO +1"
OF INSULATION LEVEL
1" RIGID INSULATION
ACCESS PANEL
DRAW ACCESS PANEL SNUG
WITH PERIMETER SCREWS
TRIM AS REQUIRED
FINISH CEILING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-404
MECHANICAL ROOM 212 ENLARGED
PLAN & ATTIC ACCESS LADDER
DETAILS
RAPJMC
SCALE: 1" = 1'-0"C1
ENLARGED PLAN - MECHANICAL ROOM 212
SCALE: NTSF3
MECHANICAL ROOM 212 PHOTO
SCALE: NTSE1
MECHANICAL ROOM 212 PHOTO
SCALE: NTSF1
MECHANICAL ROOM 212 PHOTO
SCALE: N.T.S.F6
DETAILS FOR ACCESS LADDER TO ATTIC AT 2ND FLOOR
NOTE:
1. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION
2. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
3. LADDER TO BE INSTALLED AND CERTIFIED TO MEET OSHA /ANSI STANDARDS.
4. LADDER DIMENSIONS AND CLEARANCES;16-INCH CLEAR WIDTH MINIMUM BETWEEN SIDE RAILS, 12-INCH ON CENTER, ALL RUNGS, 15 INCH MINIMUM SIDE CLEARANCE TO ANY PERMANENT OBSTRUCTION FOR LADDER,10-FEET IN
NOMINAL SPACING OF SUPPORTS.
REVISIONS DATE
SCALE: N.T.S.C8
EXISTING ATTIC ACCESS
SCALE: N.T.S.C6
CEILING ACCESS PANEL DETAIL
BRICK COMMON 3 7/8"
AIR SPACE 1 1/2" MIN.
BRICK TIES W/ SEALANT
TAPE @ ANCHORS
THROUGH WALL FLASHING
W/WEEP 24" O.C.
EXISTING WALL
TO REMAIN
2x4 WOOD STUDS
2x3 WOOD STUDS
5/8" EXTERIOR SHEATHING
W/ AIR-WATER MEMBRANE
ON OUTER FACE
MORTAR NET
2" RIGID INSULATION
1/2" GYP. BD
EXISTING WALL
TO REMAIN
0' - 4"
T O
M A
T C
H E
X
IS
T
IN
G B
R
IC
K C
O U
R S
E
M A
S O
N R
Y O
P E
N
IN
G
SLIPTRACK SYSTEMS SLP-TRK BRAND SLOTTED TRACK
#8 WAFERHEAD FRAMING SCREWS
(TYP.)
0.5" DEFLECTION GAP
0.145"x1" POWER ACTUATED FASTENER
@ 16" O.C. (MAX.) REFERENCE
FASTENER MANUF. ICBO FOR FASTENER
CAPACITY OR PER ENGINEER OF
RECORD
EXISTING CONCRETE STRUCTURAL SLAB
/2
SCALE : NTS
4 7/8" MTL. STUD PARTITION
PLAN VIEW
SCALE : NTS
6" MTL. STUD PARTITION
SCALE : NTS
4 7/8" MTL. STUD PARTITION (2-HR.
RATED SMOKE PART.)
PLAN VIEW
SCALE : NTS
1 5/8" MTL. STUD FURRING PARTITION
PLAN VIEW
SCALE : NTS
3 5/8" MTL. STUD FURRING PARTITION
FINISH CEILING
WHERE OCCURS
(SEE SCHEDULE)
MTL. STUD
FRAMING @ 1'-4"
O.C.
(1) LAYER 5/8" GWB
(ONE SIDE ONLY)
FINISH CEILING
WHERE OCCURS
(SEE SCHEDULE)
MTL. STUD FRAMING
@ 1'-4" O.C.
(1) LAYER 5/8"
GWB (EACH
SIDE)
FINISH CEILING
WHERE
OCCURS
(SEE
SCHEDULE)
MTL. STUD
FRAMING @ 1'-4"
O.C.
RUNNER TRACK
(1) LAYER 5/8"
GWB (EACH SIDE)
RUNNER TRACK
RUNNER TRACK
SMOKE/ACOUSTICAL
SEALANT BOTH
SIDES
SCALE : NTS
4 7/8" MTL. STUD PARTITION
(1-HR. RATED FIRE BARRIER)
PLAN VIEW
FINISH CEILING
WHERE OCCURS
(SEE SCHEDULE)
MTL. STUD
FRAMING @ 1'-4"
O.C.
(1) LAYER 5/8"
TYPE "X" GWB
(EACH SIDE)
RUNNER TRACK
PACK VOID TIGHT W/
MINERAL WOOL.
PROVIDE CONT. FIRE
CAULK BOTH SIDES.
COORD. W/ UL
DESIGN REQ'S
CONT FIRE
CAULK BOTH
SIDES
B.O. SLAB B.O. SLAB
SCALE : NTS
6" MTL. STUD PARTITION (2-HR.
RATED SMOKE PART.)
SCALE : NTS
7/8" Z FURRING PARTITION
SCALE : NTS
6" MTL. STUD PARTITION
(1-HR. RATED FIRE BARRIER)
2'-0". 2'-0".
TYPE A TYPE B TYPE C TYPE D
MTL. STUD BRACING
@ 4'-0" O.C. (TYP.)
PROVIDE METAL STUD BRACING @ 4'-0" O.C. (TYP.) FROM PARTITION'S TOP
TRACK TO UNDERSIDE OF ROOF / DECK STRUCTURE. GWB TO 6" ABOVE
CEILING. U.N.O.
UNDERSIDE OF STRUCTURE
MTL. STUD FRAMING @
1'-4" O.C.
TOP MTL. TRACK
GYP. BOARD PANEL.
SEE PARTITION
TYPE
FINISH CEILING
WHERE OCCURS
(SEE SCHEDULE)
TYP. MTL. WALL
ANGLE
MTL STUD BENT AT 45 DEG.
SECURED TO TOP MTL
TRACK
1. STUD DESIGN CRITERIA: ALL INTERIOR, NON-LOAD BEARING METAL STUDS SHALL BE 25 GAUGE (MIN.) AT 16" AT O.C. UNLESS OTHERWISE NOTED. STUDS SHALL BE DESIGNED FOR A 5 PSF MIN. APPLIED LATERAL LOAD, L/240 MAX. DEFLECTION. STUD THICKNESS (GA.) AND DEPTHS INDICATED ARE MINIMUMS, WHILE STUD SPACING IS A MAXIMUM ON CENTER SPACING. WHERE REQUIRED PARTITION HEIGHTS EXCEED ALLOWABLE CRITERIA, STUD THICKNESS SHALL BE INCREASED AND/OR STUD SPACING REDUCED AS REQUIRED TO MEET STATED CRITERIA. WHERE WALL HUNG CABINETS, EQUIPMENT, OR FIXTURES ARE INDICATED, PROVIDE 20
GA. MIN. STUDS.
2. ALL FIRE RATED PARTITIONS MUST EXTEND AND SEAL TO DECK ABOVE.
3. TYPICAL FLOOR PLAN DIMENSIONS OF PARTITIONS ARE TO FACE OF STUD OR CMU UNLESS NOTED
OTHERWISE.
4. INSTALLATION OF GYPSUM BOARD, BACKER BOARD, BASE BOARD, AND ALL SEALANTS, CAULKS, ETC. SHALL
CONFORM TO REQUIREMENTS FOR FIRE RATINGS AND ACOUSTICAL RATINGS.
5. PROVIDE TILE BACKER BOARD AT ALL TILE WALLS.
6. PROVIDE 5/8" GYPSUM BOARD UNLESS OTHERWISE NOTED.
7. ALL GWB TO BE TYPE X.
8. METAL STUD GAUGE (IF NOTED) AND UL TEST NUMBERS WILL VARY DEPENDING ON THE MANUFACTURER OF
COMPONENTS ACTUALLY USED.
9. PENETRATIONS IN RATED PARTITIONS AND CONNECTIONS OF THE PARTITIONS TO OTHER PORTIONS OF THE WORK SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED DETAILS AND IN COMPLIANCE
WITH APPLICABLE TESTING AGENCY REQUIREMENTS.
10. INSTALL BLOCKING, STRAPPING AND/OR BACKER MATERIAL FOR ATTACHMENT/MOUNTING OF WALL HUNG ITEMS OR EQUIPMENT DESCRIBED IN THE DOCUMENTS AS PER MANF. RECOMMENDATIONS. COMPLY WILL ALL FED., STATE AND LOCAL CODE FOR ANCHORING REQ. OFF ALL ITEMS, ACCESSORIES, RAILINGS, ETC.
11. WHEN INSTALLING GYPSUM BOARD, CONTRACTOR SHALL COMPLY WITH REQUIREMENTS OF THE MOST CURRENT EDITION OF THE GYPSUM ASSOCIATION "GA-600" FIRE RESISTANCE DESIGN MANUAL AND THE
MOST CURRENT EDITION OF THE UL FIRE RESISTANCE DIRECTORY.
12. PARTITIONS THAT ARE REQUIRED TO EXTEND TO THE DECK ABOVE SHALL HAVE THE GYPSUM BOARD CUT TO FIT WITHIN A 1/4" MAXIMUM TOLERANCE TO THE SHAPE OF THE DECK ABOVE. GYPSUM BOARD SHALL BE CONTINUOUSLY SEALED FOR THE FULL DEPTH OF THE GYPSUM BOARD WITH FLEXIBLE SEALANT.
13. GYPSUM BOARD SHALL BE CUT SO THAT THE CLEARANCE BETWEEN METALLIC ELECTRICAL OUTLET BOXES AND THE GYPSUM BOARD DOES NOT EXCEED 1/8". SEAL WITH APPROVED SEALANT PER NFPA 101 AND FBC
14. THE BOTTOM OF THE GYPSUM BOARD AT INTERIOR PARTITIONS SHALL BE 1/4" MINIMUM AND 1/2" MAXIMUM ABOVE THE CONCRETE FLOOR SLAB AND SHALL BE SEALED FOR THE FULL DEPTH OF THE GYPSUM BOARD
WITH FLEXIBLE SEALANT.
15. REFER TO THE FLOOR PLAN FOR EXTENT OF FIRE WALL RATINGS.
16. ALL ELEMENTS OF ACOUSTIC RATED PARTITIONS SHALL EXTEND TO ROOF STRUCTURE OR FLOOR DECK
ABOVE.
17. REFER TO "PARTITION TYPE SUBSCRIPT KEY" FOR SYMBOLS USED TO IDENTIFY ADDITIONAL REQUIREMENTS
AND MODIFICATIONS TO BASIC PARTITION TYPES.
18. PARTITION TYPES DESCRIBE GENERAL REQUIREMENTS FOR PARTITIONS. REFER TO THE MANUFACTURER'S SPECIFICATIONS AND REQUIREMENTS OF APPLICABLE TESTING AGENCIES FOR SPECIFICS OF PARTITION
CONSTRUCTION.
19. WHERE A CLEAR DIMENSION OR OPENING IS REQUIRED OR NOTED, MEASURE DIMENSION TO FACE OF
PARTITION FINISH.
20. REFER TO INTERIOR FINISH SCHEDULE FOR ALL WALL FINISHES.
21. PROVIDE DEFLECTION TRACK AT ALL WALL HEADS.
22. SEE U.L. ASSEMBLY LISTINGS FOR ADDITIONAL INFORMATION.
23. REFER TO FINISH AND MATERIAL SCHEDULES FOR ADDITIONAL FINISH INFORMATION AND LOCATIONS.
24. ALL ACOUSTIC BATT INSULATION SHOULD HAVE AN AIR RESISTIVITY OF R > 10 kPa s/m
25. PROVIDE (FRT) FIRE RETARDANT TREATED WOOD AT ALL WOOD LOCATIONS.
26. PROVIDE ADDITIONAL SOUND ATTENUATION MATERIALS AS NECESSARY TO SPECIFIED AREAS DESIGNATED BY THE OWNER, TO MEET ALL FED, STATE AND LOCAL CODE REQ. (INCLUDING FGI, ETC). CONTRACTOT TO
COORDINATE AND CONFIRM THE SPRCIFIED AREAS.
27. SUBMIT LIGHT GAUGE METAL FRAMING SHOP DRAWINGS SIGNED AND SEALED BY A PROFESSIONAL
ENGINEER LICENSED IN THE STATE OF TENNESSEE FOR REVIEW.
28. SEAL ALL SMALL GAPS IN WINDOW AND DOOR MOUNTING POINTS WITH ACOUSTIC SEALANT TO PREVENT
SOUND TRANSMITTANCE.
29. PROVIDE OVERSIZED WALL PENETRATIONS IN ACOUSTIC WALL ASSEMBLIES THAN NEEDED BY DUCTWORK TO ACOUSTICALLY ISOLATE THE DUCT FROM THE WALL ASSEMBLY. FILL GAPS BETWEEN WALL AND DUCT WITH ACOUSTIC SEALANT UL APPROVED (FIRE RATED IN RATED ASSEMBLIES). SEE MEP DRAWINGS FOR
ADDITIONAL INFORMATION - TYP.
30. SEAL ALL GAPS BETWEEN DIFFERENT WALL CONSTRUCTIONS AND PENETRATIONS WITH ACOUSTIC SEALANT UL APPROVED (FIRE RATED AS NECESSARY). SEE MEP DRAWINGS FOR ADDITIONAL INFORMATION - TYP.
31. PROVIDE APPROVED FIRE-RESISTANT JOINT SYSTEM AT ALL FIRE RATED UL ASSEMBLIES. CONTRACTOR TO
VERIFY SYSTEM AND INTEGRITY (TYP. AT ALL JOINTS IN RATED WALLS).
GENERAL PARTITION NOTES:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-501
PARTITION TYPES & DETAILS
RAPJMC
SCALE: 1 1/2" = 1'-0"F3
HEAD OF WALL CONNECTION DETAIL
SCALE: 1 1/2" = 1'-0"F1
STUD BRACING DETAIL
SCALE: = 1'-0"1 1/2"
01 1
SCALE: 1 1/2" = 1'-0"F5
BRICK INFILL DETAIL
COMPRESSION POST TO STRUCTURE
NOTE:
FOR FIXTURES WEIGHING 56LBS OR MORE,
INSTALL #12 GAUGE HANGER WIRE ATTACHED
TO STRUCTURE ABOVE - ONE AT EACH CORNER
OF FIXTURE FOR A TOTAL OF FOUR. HANGER
WIRES MUST BE INSTALLED VERTICAL BUT NOT
MORRE THAN 1 IN 6 OUT OF PLUMB. FOR
FIXTURES WEIGHING LESS THAN 56 LBS,
WIRES MAY BE INSTALLED SLACK AT TWO
CONERS ONLY.
TYPICAL LAY-IN
FLUORESCENT
TROFFER
# 12 SUPPORT WIRE TO STRUCTURE
EARTHQUAKE CLIP-ONE ON
EACH CORNER FOR A TOTAL OF FOUR
TYPICAL GRID
"TEE" CEILING
MAIN RUNNER
8" MAX 8" MAX PLAY BRACING DETAIL
(REQUIRED @ ROOMS OVER 1000 SF)
12 GA HANGER WIRE. INSTALL EITHER SLOPED
(1:6 MAX) OR VERTICALLY
1 IN 6
MAX
12 GA HANGER WIRE.
INSTALL EITHER
SLOPED (1:6 MAX) OR VERTICALLY
1 IN 6
MAX
ATTACHMENT NOTES:
3/4" MIN
TEE END RETAINING CUP 3/4" MIN
CEILING MOUNTED AIR TERMINALS
OR SERVICES WEIGHING 20 LBS. OR
LESS SHALL BE POSITIVELY
ATTACHED TO THE CEILING
SUSPENSION MAIN RUNNERS OR
CROSS RUNNERS.
SCREW ATTACH
GRID TO CLIP
2".
WALL ANGLE, ATTACH TO
WALL
ATTACH ALL TEES TO WALL ANGLE
2".
WALL ANGLE, ATTACH TO WALL
AIR TERMINALS OR SERVICES
WEIGHING MORE THAN 20 LBS AND
LESS THAN 56 LBS SHALL HAVE,
IN ADDITION TO THE ATTACHMENTS
NOTED ABOVE, TWO NO. 12 GAUGE
HANGERS CONNECTED TO THE CEILING
SYSTEM HANGERS OR TO THE
STRUCTURE ABOVE. WIRES MAY BE
SLACK.
AIR TERMINALS OR SERVICES
WEIGHING MORE THAN 56 LBS
SHALL BE SUPPORTED DIRECTLY
FROM THE STRUCTURE ABOVE BY
APPROVED HANGERS.
B.1
A.1 DETAIL @ TWO ADJACENT
WALLS WITH GRID ATTACHED
TO WALL ANGLE
DETAIL @ TWO ADJACENT
WALLS WITH GRID ATTACHED
TO WALL ANGLE
AIR TERMINAL/ SERVICES SEISMIC
RESTRAINT DETAIL
NO SCALE
NO. 12 GAUGE HANGER
WIRE. TYPICAL OF 2.
OR
8" MAX
12 GA HANGER WIRE.
INSTALL EITHER
SLOPED (1:6 MAX) OR VERTICALLY
1 IN 6
MAX
12 GA HANGER WIRE.
INSTALL EITHER
SLOPED (1:6 MAX) OR VERTICALLY
8" MAX
12 GA HANGER WIRE.
INSTALL EITHER
SLOPED (1:6 MAX) OR
VERTICALLY
3/4" MIN
TEE END RETAINING CLIP 3/4" MIN
CEILING GRID MAIN
RUNNER (TYPICAL)
NO ATTACHMENT- GRID TO CLIP
2".
WALL ANGLE, ATTACH TO WALL
SPACER BAR BETWEEN ALL TEES
2".
WALL ANGLE, ATTACH TO WALL
1 IN 6
MAX CEILING GRID CLIPS AND/OR
METAL CLIPS FASTENED WITH
MECHANICAL FASTENERS TO
GRILLES, TERMINAL DEVICES AND
CEILING GRID MAIN RUNNERS
LAY-IN CEILING
GRILLE OR TERMINAL
HANGER WIRE
A.2 DETAIL @ TWO ADJACENT
WALLS WITH NO ATTACHMENT
TO WALL ANGLES
B.2 DETAIL @ TWO ADJACENT
WALLS WITH NO ATTACHMENT
TO WALL ANGLES
D
E G
R E
E M
A X
2" M
AX)
2'-0" U.N.O.
8'-0"
CEILING PLAN
5" U.N.O.
CONTINUOUS CORNER BEAD
(1) LAYER, 5/8" GYPSUM BOARD ON
3 1/2" WOOD STUDS @ 16" O.C. TYP.
(1) LAYER, 5/8" GYPSUM BOARD ON
3 1/2" WOOD STUDS @ 16" O.C. TYP.
CONTINUOUS CORNER BEAD
8'-0"
CEILING PLAN
SEE REFLECTED
CEILING PLAN
SEE REFLECTED
CEILING PLAN
1'-0" TYP.
WOOD STUD BRACE @ 48" O.C.
TO UNDERSIDE OF STRUCTURE ABOVE
ACOUSTICAL CEILING SYSTEM, SEE FINISH
SCHEDULE FOR HEIGHT AND SPECIFICATIONS
EXTEND WOOD STUDS TO UNDERSIDE
OF STRUCTURE ABOVE
1''-0" TYP.
ACOUSTICAL CEILING SYSTEM, SEE FINISH
SCHEDULE FOR HEIGHT AND SPECIFICATIONS
WOOD STUD BRACE @ 48" O.C.
TO UNDERSIDE OF STRUCTURE ABOVE
O C
C U
R S
A T
W
IN
D O
W C
O N
D
IT
IO
N
S
M
IN
M
IN
W A
L L T
Y P
E S
S E
E F
L O
O R
P L A
N S
M
IN
M
IN
45° MIN.
V A
R
IE
S
LIGHTOLIER FLUORESCENT,
LYTETUBE RT622182,
3-1/2" MET. STUDS
STRUCT. ABOVE
LIGHT BEYOND
INCANDESCENT DOWN
FRAMED TO
1/2" GWB REVEAL
PT. CEIL. WHITE
16" O.C.
PT. CEIL. WHITE
6" MET. STUDS @
1/2" GWB. OVER
(2) 8' SECTIONS
ATTACHED SIDE UNATTACHED SIDE
6 #12 HANGER WIRE
ANCHORED TO
STRUCTURE
ABOVE8" MAX.
STABILIZER BAR
TWO ADJACENT SIDES
0' - 1" MIN.
NOTE: WHERE CEILING IS MORE THAN 144 SQUARE FEET, THE GRID MUST BE CONNECTED TO THE PERIMETER ON TWO ADJACENT SIDES
#12 HANGER
WIRE ANCHORED
TO STRUCTURE
ABOVE
8" MAX.
STABILIZER BAR
ENDPLATE
INSIDE
LINE
OF
LINTEL
S T
R U
C T
U R
A L O
P E
N
IN
G
B E
T W
E E
N E
N D
P L A
T E
S
B E
T W
E E
N G
U
ID
E S
ENDPLATE
CHAIN
WHEEL
HAND
CHAIN
INSIDE
H E
A D
R O
O M
O P
E N
IN
G
H E
IG
H
T
SECURE
FIXINGS
SECTION
PLAN
NOTES:
1. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION
2. MANUAL CLOSING IS ACHIEVED BY RELEASING A PULL CHORD OR PULLING ON HAND CHAIN, WHICH ALLOWS A
CONTROLLED DECENT VIA A GEAR UNIT
3. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
4. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN
PROFESSIONALS FOR PLANNING PURPOSES ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.
5. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED
AND APPROVED BY THE PRODUCT MANUFACTURER TO BE CONSIDERED ACCURATE.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-502
REFLECTED CEILING DETAILS
RAPJMC
SCALE: = 1'-0"3"
SCALE: 1/8" = 1'-0"F1
CEILING SEISMIC INFO
SCALE: 3" = 1'-0"B1
CEILING WD SPECIAL SOFFIT
SCALE: = 1'-0"1 1/2"
01 1
SCALE: 3" = 1'-0"B6
SEISMIC 7/8" ANGLE DETAIL
SCALE: 1 1/2" = 1'-0"D8
DRYWALL CEILING DETAIL IN WAITING ROOM
SCALE: = 1'-0"
0 8 168
1/8"
SCALE: N.T.S.F8
DETAILS FOR FIRE PROTECTED SMOKE CURTAIN
SEE REFLECTED
CEILING PLAN
SEE REFLECTED
ACOUSTICAL CEILING SYSTEM, SEE FINISH
SCHEDULE FOR HEIGHT AND SPECIFICATIONS,
TYP.
VARIES, SEE REF. CEILING PLAN
CONTINUOUS CORNER
BEAD
ORIENTATIONS PER
RCP
(1) LAYER , 5/8" GYPSUM BOARD ON
3 1/2" STUDS @ 16" O.C. TYP.
SEE REFLECTED
CEILING PLAN
3 1/2" WOOD STUD DIAGONAL BRACING
@ 48" O.C.
EXTEND WOOD STUDS
TO UNDERSIDE OF
STRUCTURE ABOVE
M
IN
CEILING PLAN
2" C/S GROUP
EXP. JT. MODEL HC
2" C/S GROUP
EXP. JT. MODEL HC
WALL
SUSPENDED CEILING SYSTEM
CEILING STRUCTURE
ANCHOR @ 2'-0" O.C.
NOTE: USE NEAR BUILDING EXTERIOR WALL
STRUCTURAL SOFFIT
WALL
PERIMETER CHANNEL
PRESSED STEEL
CEILING SECTION
CEILING FINISH
THICK PLASTERBOARD
SCREWED TO CEILING
SECTIONS
MILD STEEL CHANNELS
ANGLE CLEATS
SLOTTED BOLT FIXINGS
TO PROVIDE LEVELING
ADJUSTMENT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-503
REFLECTED CEILING DETAILS
RAPJMC
SCALE: = 1'-0"3"
SCALE: 3" = 1'-0"B3
CEILING WD BULK HEAD AT TRANSITION
SCALE: 3" = 1'-0"B7
CEILING SUSPENDED CEILING EXP. JOINTS
SCALE: 3" = 1'-0"B1
SUSPENDED DRYWALL CEILING DETAIL
EXPOSED CABINET EDGES:
3MM PVCT MOLD TO MATCH
ADJACENT LAMINATE, TYP.
PL-1 BASE AS
SCHEDULED.
1/4" PLYWOOD ON
1 X 4 BLOCKING
BULLNOSE EDGE.
SP-1 COUNTERTOP
(SOLID SURFACE)
NEOPRENE PIPE
COVER ACCEPTABLE
TO ADA.
1' - 3"
RECESSED ADJUSTABLE
METAL STANDARDS
1X4 BLOCKING
ADJUSTABLE
PL-1 SHELVING, TYP.
PL-1 CABINET.
" SOFFIT; LIGHT GAUGE
METAL FRAMING
M A
X
2' - 0"
1/2" PLYWOOD
INTEGRAL BACKSPLASH
NOTE: REFER TO ELEVATIONS TO CONFIRM LOCATION.
COUNTERTOP - REFER
TO ELEVATIONS & DETAILS
FOR MORE INFORMATION
METAL SUPPORT BRACKET
(SEE ARCHITECTURAL SPECIFICATIONS)
1 1/2"
SPLASH AT BACK AND ENDS;
HEIGHT & LOCATIONS AS
INDICATED ON ELEVATIONS
R E
F E
R T
O E
L E
V A
T
IO
N S
F O
R H
E
IG
H
T2' - 0"TYP. 1"
FLUSH BOTTOM AT
KNEE SPACES
SQUARE EDGE; TYP.
/2
3/4"
SPLASH AT BACK AND ENDS; HEIGHT &
LOCATIONS AS INDICATED ON ELEVATIONS,
NO SOLID SURFACE BACK SPLASH WHERE
TILE BACK SPLASH IS USED, SEE
ELEVATIONS
COUNTERTOP DEPTH = 2'-1" TYPICAL AND 1'-9" AT
LAVATORIES U.N.O., REFER TO PLANS AND ELEVATIONS.
R E
F E
R T
O E
L E
V A
T
IO
N S
F O
R H
E
IG
H T
2' - 0"TYP; 1"
1/2"
FLUSH BOTTOM AT
KNEE SPACES
SQUARE EASED EDGE; TYP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-504
MILLWORK DETAILS
RAPJMC
SCALE: 3" = 1'-0"B1
TYP. CABINET DETAILS
SCALE: 1 1/2" = 1'-0"F1
SECTION @ ADA SINK
SCALE: 3" = 1'-0"F3
BASE CABINET
GENERAL MILLWORK NOTES
1. PROVIDE FRT BLOCKING FOR MILLWORK AND TRIM AS REQUIRED FOR RIGID
CONDITION. ALL CABINETS TO BE SUPPORTED AT BASE AND OTHER AREAS AS
REQUIRED FOR FULLY RIGID CONDITION. PROVIDE STIFFNERS PRE SUPPORT AS
REQUIRED VERIFY W/ OWNER PFOVIDED EQUIP.
2. CONTRACTOR TO FIELD VERIFY ALL RELEVANT EXISTING DIMENSIONS AND
CONDITIONS PRIOR TO FABRICATION OF BUILT-IN CABINETRY, TYP.
3. SUBMIT SHOP DRAWINGS SHOWING LOCATION OF EACH ITEM, DIMENSIONS OF
PLANS AND ELEVATIONS, LARGE SCALE DETAILS, SAMPLES, CUT SHEETS,
ATTACHMENT DEVICES AND OTHER COMPONENTS FOR REVIEW AND APPROVAL BY
ARCHITECT.
4. PROVIDE FIRE RETARDANT TYPE WOOD BLOCKING IN WALLS WHERE REQUIRED FOR
NEW MILLWORK AND OTHER WALL MOUNTED ITEMS. COORDINATE WITH WALL
TYPES, TYPCIAL.
5. LOCATIONS FOR OWNER-PROVIDED EQUIPMENT SHOWN ARE APPROXIMATE. VERIFY
EQUIPMENT SIZES & FINAL LOCATIONSNF PRIOR TO MILLWORK
FABRICATION.
6. ELEC. & DATA OUTLET LOCATIONS SHOWN ARE APPROXIMATE. COORDINATE &
VERIFY LOCATIONS W/ OWNER-PROVIDED EQUIPMENT VENDOR PRIOR TO
INSTALLATION.
7. ALL FASTENERS SHALL BE CONCEALED.
8. FIELD INSTALL GROMMET HOLES IN ALL BUILT IN CABINETS FOR ELECTRIAL CORDS
ALONG WITH PROVIDING ADDITIONAL GROMMETS WHERE INDICATED. ALL HOLES
SHALL BE 2" DIAMETER. ALL GROMMET HOLES SHALL RECEIVE PLASTIC TRIM.
9. COORDINATE ALL MILLWORK WITH PLUMBING, ELECTRIAL EQUIP. AND PIPING AS
REQUIRED FOR FULLY OPERATIONAL CONDITION.
10. ALL CABINETS TO BE SUPPORTED AT BASE AND OTHER AREAS AS REQUIRED FOR
FULLY RIGID CONDITION. PROVIDE STIFFENERS FOR SUPPORT AS REQUIRED.
11. CABINET FACE TYPES SHALL BE FLUSH OVERLAY, UNLESS NOTED OTHERWISE.
12. ALL BASE CABINETS, WALL CABINETS, AND TALL CABINETS SHALL HAVE FINISHED
END PANELS AT ENDS UNLESS NOTED OTHERWISE. SHOP DRAWINGS TO INDICATE
THIS.
13. CABINET BASE AT FLOOR TO HAVE FINISH AS INDICATED FOR ROOM OR AS
DETAILED.
14. PROVIDE BACKING PLATES, ANCHORS, FASTNERS, ETC. AS NESSESARY TO PROVIDE
A SECURE AND RIGID CONNECTION FOR ALL MILLWORK TO WALLS, ETC.
15. TYPICAL CABINETRY PROFILES SHOWN TO CONVEY CRITICAL DIMENSIONS. REFER
TO ELEVATIONS FOR SPECIFIC CONFIGURATIONS. REFER TO SPECIFICATIONS FOR
JOINERY AND QUALITY REQUIREMENTS.
16. MINIMIZE OPEN JOINTS IN COUNTERTOPS. SEAL ANY OPEN JOINTS WITH FDA
APPROVED SILICONE SEALANT COLOR AS SELECTED BY ARCHITECT FROM FULL
RANGE OF COLORS (INCLUDING CUSTOM MIXED COLORS).
17. COUNTERTOPS TO HAVE 2" RADIUS AT ALL EXPOSED HORIZ. OUTSIDE CORNERS,
UNLESS NOTED OTHERWISE.
18. GROMMETS - PROVIDE A STAINLESS STEEL GROMMET SAT EACH LOCATION WHERE
POWER AND/OR SIGNAL DEVICE OCCUR BELOW A COUNTERTOP, UNLESS NOTED
OTHERWISE.
19. FIELD VERIFY ALL MILLWORK LOCATION DIMENSIONS PRIOR TO MAT. ORDER,
FABRICATION AND CONSTRUCTION.
20. CONTRACTOR TO PROVIDE CABINET HARDWARE AND ACCESSORY MATERIALS
ASSOCIATED WITH CABINETWORK.
21. SEE CASEWORK FINISH SCHEDULE ON IG603 FOR FINISHED MATERIAL.
SCALE: 1 1/2" = 1'-0"F9
COUNTERTOP SUPPORT BRACKET
SCALE: 1 1/2" = 1'-0"D6
TYP. LAMINATE COUNTERTOP
SCALE: 1 1/2" = 1'-0"B6
TYP. SOLID SURFACE COUNTERTOP
SCALE: = 1'-0"3"
SCALE: = 1'-0"1 1/2"
01 1
SCALE: = 1'-0"3/4"
0 1 2 31
SCALE: 3/4" = 1'-0"F6
RECEPTION STATION
/4
1 1/4"
/4
CORNER GUARD
ON 5/8" GWB ON
3 1/2" MTL STUD
RB - 1
(SEE FINISH SCHEDULE)
C E
IL
IN
G H
E
IG
H T
-S E
E S
C H
E D
U L
E
CEILING AS
SCHEDULED
BASE AS
SCHEDULED
CG-1
DOOR FRAME
CG-1
GC TO PROVIDE CONT.
BLOCKING AS REQUIRED
FOR RIGID CONDITION
CG-1
GC TO PROVIDE CONT.
BLOCKING AS REQUIRED
FOR RIGID CONDITION
5/8" GWB ON 3 5/8"
MTL STUD
END WALL
CORNER WALL
REMOVE EXCESS MORTAR FROM COLLAR JOINT,
100% PARGE (MIN 5/8") AND FLOAT SMOOTH
ENTIRE SURFACE OF EXPOSED BACK UP
LIQUID BARRIER; PROVIDE PER MANUFACTURERS
SPECIFICATIONS, INCLUDING ALL JOINT/ CORNER/
TRANSITION REINFORCEMENT
RECESS NEW MORTAR 3/4"" AND REPOINT 3
DAYS AFTER BRICK HAVE BEEN REPLACED
S/S TIES ANCHORED TO BACK -UP WALL W/ S.S
ZAMAC ANCHORS @ 16" O.C. STAGGER BRICK
TIES (HORIZONTALLY AND VERTICALLY)
FACE BRICK TO MATCH
EXISTING FACE BRICK
NOTE: ALL MASONRY REPAIRS
TO COMPLY AND ADHERE TO
B.I.A TECHNICAL NOTES AND
PROCEDURES.
OPEN
WEEPS AT
16" O.C. NO
PLASTIC
TUBES
GROUND OUT
MIN. 3/4" DEEP
INTO MORTAR
JOINTS
TUCK POINT
MORTAR
JOINTS IN 1/4"
LAYERS
TOOL JOINTS
W/ CONCAVE
PROFILE
2"
BRICK REPLACEMENT W/ AIR WATER BARRIER BRICK REPOINTING AND SAMPLE WEEP
TUCK POINT MORTAR
JOINTS IN 1/4" LAYERS
TOOL JOINTS W/
CONCAVE PROFILE
GROUND OUT MIN. 3/4"
DEEP INTO MORTAR JOINTS
EXISTING STONE BANDING
NEOPRENE PADDING.
REMOVE ALL MORTAR AND
DEBRIS WITHIN JOINT
S/S JOINT STABILIZERS @ 12" O.C.
CAULKING W/ BACKER ROD AND
NEOPRENE PADDING, TYP.
3/4"
1/2"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-505
CORNER GUARD AND
MISCELLANEOUS DETAILS
RAPJMC
SCALE: NTSA8
CORNER GUARD DETAIL
SCALE: 6" = 1'-0"C2
CORNER GUARD WALL DETAIL
SCALE: NTSC5
TYP. CORNER GUARD ELEVATION DETAIL
SCALE: 3" = 1'-0"C8
TYP. CORNER GUARD DETAIL PLAN
TARKETT VBG-XX-C CORNER GUARD
BRAND: TARKETT/ JOHNSONITE
HEIGHT: 1-1/4" MILLWORK TPR
CHEMICAL RESISTANCE: GOOD
SLIP RESISTANCE: SCOF ≥ 0.5
FLAMMABILITY: CLASS 1 (≥ 0.45 W/CM²)
SMOKE DENSITY: < 450
FLAME SPREAD/SMOKE DENSITY: CLASS B < 450 SMOKE
SCALE: = 1'-0"6"
SCALE: = 1'-0"3"
SCALE: N.T.S.F1
BRICK REPLACEMENT/ REPOINTING / WEEP DETAILS
SCALE: N.T.S.F5
STONE REPOINTING DETAIL
SCALE: N.T.S.F8
EXPANSION JOINT STABILIZER
1 1/2" TYP.
MDF BACKER BOARD.
SEE DETAIL C4/A-506
SOLID SURFACE WAINSCOT BEYOND
MIRROR
1' - 9"
1/4" TYP.
/2
T Y
P
MDF BACKERBOARD TO MATCH S-3
THICKNESS. EDGES PAINTED BLACK.
PROVIDE SECURE WALL ATTACHMENT
SETTING BED
MDF BACKER BOARD PAINTED TO MATCH WALL COLOR
MIRROR
1/4" THICK SOLID SURFACE WAINSCOT
3"
O .C
. 2"
DRYWALL/
MILLWORK
AS
SPECIFIED
4" WIDE BATTER STRIP AT
EACH ARMORCORE SEAM
STEEL OR WOOD STUDS,
AS SPECIFIED
ARMORCORE® BULLET
RESISTANT PANEL
DRYWALL/MILLWORK SEAM
TO BE PLACED OFFSET
FROM ARMORCORE PANEL
DRYWALL/MILLWORK AS
SPECIFIED
STEEL OR WOOD STUDS,
AS SPECIFIED
ARMORCORE® BULLET
RESISTANT PANEL
DRYWALL/MILLWORK, AS
SPECIFIED
DRYWALL/MILLWORK, SEAM
TO BE PLACED OFFSET
FROM ARMORCORE PANEL
4" WIDE BATTEN STRIP AT
EACH ARMORCORE SEAM
ARMORCORE® BULLET
RESISTANT PANEL
STEEL OR WOOD STUDS,
AS SPECIFIED
ISOMETRIC VIEWSECTION VIEW
PLAN VIEW
NOTES: (PROTECTION LEVEL 5)
1. INSTALLATION TO BE COMPLETED IN ACCORDANCE
WITH MANUFACTURER'S SPECIFICATIONS.
2. DO NOT SCALE DRAWING.
3. THIS DRAWING IS INTENDED FOR USE BY
ARCHITECTS, ENGINEERS, CONTRACTORS,
CONSULTANTS AND DESIGN PROFESSIONALS FOR
PLANNING PURPOSES ONLY. THIS DRAWING MAY
NOT BE USED FOR CONSTRUCTION.
4. ALL INFORMATION CONTAINED HEREIN WAS
CURRENT AT THE TIME OF DEVELOPMENT BUT MUST
BE REVIEWED AND APPROVED BY THE PRODUCT
MANUFACTURER TO BE CONSIDERED ACCURATE.
BEARING BAR
CROSS BAR
WIDTH OF NEW GRATING TO BE INSTALLED
CORNER POST
CONNECTION
TWO - WAY
POST
CONNECTION
PERIMETER ANGLE
SWING GATE AT BASEMENT LEVEL CONNECTED TO
OVERHEAD NEW GRATING AND CONCRETE FLOORING
BELOW
FINISH SPECIFICATION
BLACK POLYESTER POWDER COAT - STANDARD
HOT DIP GALVANIZE - OPTIONAL
STAINLESS STEEL - OPTIONAL
SHOP BLACK - STANDARD
GALVANIZED STEEL BANDED BAR GRATE - #EG-1436-HGBG
STAINLESS STEEL BANDED BAR GRATE - #EG-1436-HSBG
PAINTED STEEL BANDED BAR GRATE - #EG-1436-HPBG (STANDARD)
17' - 11"
S P
A N
1 1/4 X 3/16 GALVANIZED STEEL BAR GRATING
CORNER POST CONNECTION
FOR CONNECTION OF PERIMETER
ANGLE AT A CORNER
TWO -WAY POST CONNECTION
FOR CONNECTION AT AN INTERSECTION
TYPICAL WALL CONNECTION
FOR CONNECTING PERIMETER ANGLE OR
PANELS TO WALL. USE APPROPRIATE
ANCHOR IN CONCRETE / MASONRY WALL
TYPICAL FLOOR ANCHORING
CONNECTION
FOR CONNECTING STANDARD POSTS TO A
CONCRETE FLOOR
NOTE: PROVIDE BRACKETS, BLOCKING, & ANCHOR AS REQUIRED FOR RIGID CONDITION.
1/2"
HEIGHT OF GRATING
E X
IS
T
IN
G
M A
S O
N R
Y W
A L L
EXISTING COPING
PERIMETER ANGLE
CONNECTION POST
TRENCH WIDTH
NOTES FOR GRATING INSTALLATION:
1. GRATINGS MUST BE INSTALLED WITH CROSS BARS ON TOP
SIDE
2. NOTCHING OF BEARING BARS AT SUPPORTS TO MAINTAIN
PROPER ELEVATION IS GENERALLY NOT RECOMMENDED. IF
NOTCHING IS REQUIRED FOR INSTALLATION,
MANUFACTURER SHOULD BE CONSULTED.
3. METAL SHOULD ALWAYS BE USED FOR ALL GRATING
SUPPORTS
4. A MINIMUM OF 1" BEARING SHALL BE PROVIDED FOR
ALUMINUM AND LIGHT DUTY STEEL GRATING. FOR HEAVY
DUTY STEEL GRATING 1" MINIMUM BEARING BAR DEPTHS
UP TO 2-1/4", AND 2" MINIMUM BEARING SHALL BE PROVIDED
FOR DEPTHS OF 2- 1/2" AND OVER. THIS BEARING SURFACE
DOES NOT INCLUDE THE SUPPORT ANGLE FILLET RADIUS
NOTED.
E X
IS
T
IN
G
C O
N C
R E
T E
1/2" ∅ ADH ANCHOR W/ 3"
EMBEDMENTS @ 24" O.C. TYP.,
USING HILTI HY 20 OR APPROVED
ALT. USE MESH TUBE @ HOLLOW
MASONRY
L 4 X 3 X 3/16 (LONG VERTICAL), TYP.
SWING GATE
EXISTING COPING
E X
IS
T
IN
G
M A
S O
N R
Y W
A L L
CONNECTION POST
PERIMETER
ANGLE HEIGHT OF GRATING
USE APPROPRIATE ANCHOR IN
CONCRETE / MASONRY WALL
FILLER
CONNECTING POSTS TO
CONCRETE FLOOR
NOTES:
1. THE OPENING SHALL BE BUILT TO ACCOMODATE THE DOOR JAMB
PER THE OWNERS SPECIFICATIONS.
2. KEYED ACCESS FROM SWING GATE. NOT ALL HARWARE IS SHOWN,
REFER TO PRODUCT/ MANUFACTURER'S SEPECIFICATIONS.
3. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH
MANUFACTURERS SPECIFICATIONS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-506
MISCELLANEOUS DETAILS
RAPJMC
SCALE: 1 1/2" = 1'-0"D1
MIRROR AT SOLID SURFACE WAINSCOT
SCALE: 3" = 1'-0"B1
SECTION THROUGH MIRROR AT SOLID SURFACE WAINSCOT
SCALE: = 1'-0"3"
SCALE: = 1'-0"1 1/2"
01 1
SCALE: = 1'-0"3/8"
0 2 4 62
SCALE: N.T.S.F1
BULLET RESISTANT CONSTRUCTION
SCALE: 1/2" = 1'-0"C4
PLAN OF GRATING AT BASEMENT STAIRWELL
SCALE: 3/4" = 1'-0"C8
TYPICAL CONNECTIONS AT NEW GRATING
SCALE: 1 1/2" = 1'-0"F4
SECTION AT GRATING
SCALE: 1" = 1'-0"F8
DETAILS FOR SWING GATE AT BASEMENT LEVEL
WALL OPENING
MOUNTING
HOLES 1/4"
OPTIONAL
MASONRY
ANCHOR
STRIP
FINISH LINE OF
WALL SURFACE1-1/2" MINIMUM CLEARANCE
B
A
WALL OPENING
WALL OPENING
MOUNTING
HOLES 1/4"
OPTIONAL
MASORY
ANCHOR
STRIP
FINISH LINE OF
WALL SURFACE
B
A
WALL OPENING
LATCH
HINGE
FRONT ELEVATION SECTION DETAIL
FRONT ELEVATION SECTION DETAIL
NOTES:
1. VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FABRICATION
2. CONTRACTOR RESPONSIBLE TO COORDINATE ALL ALUMINUM FRAMES WITH ALL RELEVANT DETAILS DEPICTED THROUGHOUT DRAWINGS.
3. COORDINATE ALL ALUMINUM FRAMES WITH SPECIFICATION REQUIREMENTS, INCLUDING BUT NOT LIMITED TO PROVIDING ENGINEERING TO VERIFY WIND LOADING CRITERIA IS MET IN
ALL CASES. SEE STRUCTURAL DRAWINGS.
4. SEE STRUCTURAL DRAWINGS FOR REQUIREMENTS FOR LINTELS IN MASONRY WALLS AND FOR SUPPORT REQUIREMENTS AT OPENINGS IN STEEL FRAMING
5. DRAWINGS REPRESENT DESIGN INTENT. SHOP DRAWINGS ARE REQUIRED PRIOR TO FABRICATION.
6. COORDINATE ALL HARDWARE WITH SPECIFICATIONS
7. HOLLOW METAL FRAMES SHALL BE ANCHORED TO THE STRUCTURAL SURROUNDINGS WITH A MINIMUM OF TWO (2) ANCHOR BOLTS.
8. HOLLOW METAL FRAMES IN MASONRY WALLS SHALL BE FILLED WITH GROUT
OPTION (A): TURN KEY/ LATCH
OPTION (B): FIXED
EXISTING ARC OPENING AT MASONRY WALL
EXISTING ROUGH OPENING AT MASONRY WALL TO BE FILLED
TO A FIXED DIMENSION OF 24" X 24".
NOTES:
1. ALL NEW WORK SHALL BE IMPLEMENTED SO AS
TO PROVIDE A SMOOTH AND CONTINUOUS
SURFACE WITH ALL EXISTING CONDITIONS.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
WORK NECESSARY TO ACHIEVE THIS THIS
REQUIREMENT, EVEN THOUGH PROCEDURES
ARE NOT DETAILED FOR EACH SPECIFIC
CONDITION OR COMBINATION OF CONDITIONS.
2. PATCH AND REPAIR (EXTEND, RESTORE,
AND/OR CLOSE OPENING) ALL EXISTING
SURFACES DAMAGED BY DEMOLITION AND/ OR
INSTALLATION OF NEW WORK AND/ OR
UTILITIES, AS REQUIRED TO MATCH ADJACENT
SURFACES
3. SLECTIVELY REMOVE CRACKED BRICK OR
SPALLS GREATER THAN 1" AREA AND 1/4" DEPTH.
REMOVALS TO BE FIELD MARKED FOR
APPROVAL BY THE ARCHITECT PRIOR TO
REMOVAL. INSTALL NEW BRICK TO MATCH
EXISTING, NEW BRICK TIES AND ANCHRS AS
REQUIRED AND REMORTAR.
NEW BRICK TO BE INSTALLED TO FILL THE
EXISTING ROUGH OPENING AT MASONRY
NEW ACCESS PANEL FRAME AT FIXED
DIMENSIONS 24" X 24"
CRACKS LINES
REMOVE DAMAGED OR CRACKED
MASONRY BRICK. INSTALL NEW BRICK TO
MATCH EXISTING. REFER TO BRICK
REPAIR NOTES ON SHEET C5/ A-512
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-507
ACCESS WALL OPENING DETAILS
HMPRKP
SCALE: N.T.S.F6
DETAILS FOR ACCESS WALL OPENINGS
SCALE: N.T.S.C1
A. EXISTING ARC OPENING AT BRICK MASONRY - FIXED OPTION
SCALE: N.T.S.F1
C. EXISTING ROUGH OPENING AT BRICK MASONRY - FIXED OPTION
1. THERE ARE THREE (3) LOCATIONS AT THE BASEMENT LEVEL WHERE AN ACCESS PANEL HAS BEEN CALLED OUT;
A. EXISTING ARC OPENING AT BRICK MASONRY
B. NEW OPENING (24" X 24") AT BRICK MASONRY
C. EXISTING ROUGH OPENING TO BE FILLED AND/ OR PATCHED TO A FIXED DIMENSION OF 24" X 24"
GENERAL NOTES
NOTE: SIMILAR DETAIL AT BASE (OPPOSITE END)
AT FIRE DAMPERS WITH SHAFT WALL CONSTRUCTION
NOTE: OWNER TO SPECIFY LOCATION(S)
OF FEC. CONTRACTOR TO CONFIRM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-508
STANDARD FIRE PROTECTION DETAILS
RAPJMC
SCALE: N.T.S.B1
DETAIL WALL WITHIN 12 OF BEAM
SCALE: N.T.S.C1
RATED WALL UNDER BEAM
SCALE: N.T.S.E1
RATED WALLS OR SMOKE WALL UNDER BEAM (JOIST SIM)
SCALE: N.T.S.D4
SCHEMATIC ABUTMENT OF DISSIMILIAR PARTITIONS
SCALE: N.T.S.E4
PARTITION PRIORITY LEGEND
SCALE: N.T.S.C6
TYP STUD LOCATIONS AT FIRE DAMPERS IN RATED WALLS
SCALE: N.T.S.F1
TYPICAL RATED PARTITION DETAIL
SCALE: N.T.S.F4
TYP 5 8 GB PATCHES AT NEW AND EXISTING OPENINGS
SCALE: N.T.S.E6
SCHEMATIC RATED WALL TO EXTERIOR WALL
SCALE: N.T.S.F6
DRYWALL RATED PARTITIONS
SCALE: N.T.S.B8
STUD LOCATIONS
SCALE: N.T.S.B4
RECESSED FIRE EXTINGUISHER CABINET
SCALE: N.T.S.B6
TYP RECESSED CABINET IN RATED PARTITION
STONE BANDING:
100% CLEAN AND 100%
INSTALLATION OF NEW
MORTAR JOINTS
120"
90"
85"
23 1_
37"
REMOVE
AND
DISCARD
EXITING
METAL
RAILINGS
REMOVE AND DISCARD
EXITING METAL RAILINGS
16 1_ " 39 3_
12 1_
12 3_
11 1_
49"
FRONT ELEVATION SIDE ELEVATION
39 3_
12 1_
12 3_
11 1_
49"
1/2" EXPANSION JOINT
NEW METAL RAILING
TO BE INSTALLED
AND POWDER COATED.
NEW 4" CONCRETE
PAVEMENT SLAB
EXISTING STONE TO BE
CLEANED AND REPAIRED
NEW CONCRETE
STAIR TO MATCH
STONE IN COLOR.
V.I.F.
1/2" EXPANSION JOINT
SLOPE
6"
TOOL JOINT
TOOL EDGE
1' - 0"
1/2" EXPANSION JOINT
NEW METAL RAILING
TO BE INSTALLED AND
POWDER COATED .
NEW 4" CONCRETE
PAVEMENT SLAB
EXISTING MASONRY
TO REMAIN
EXISTING STONE TO BE
CLEANED AND REPAIRED
EXISTING STONE BANDING
TO BE CLEANED AND 100%
REPOINTING OF ALL STONE
JOINTS
NEW CONCRETE STAIR
TO MATCH STONE IN
COLOR. V.I.F.
42" 1' - 0"
KEY JOINT OR
SLIP DOWELS
3"
MIN
REINFORCEMENT STEEL
1/2" EXP. JOINT
REMOVE AND DISCARD
EXITING METAL RAILINGS
REMOVE AND DISCARD
EXITING METAL
RAILINGS
35"
12"
12"
12"
24"
80 3_
73"
16"
33 1_
STONE
BANDING:
100% CLEAN
AND 100%
INSTALLATION
OF NEW MORTAR
JOINTS
FRONT ELEVATION SIDE ELEVATION
1/2" EXPANSION JOINT
NEW 4" CONCRETE PAVEMENT SLAB
EXISTING STONE TO BE CLEANED AND REPAIRED
EXISTING STONE BANDING TO BE CLEANED AND
100% REPOINTING OF ALL STONE JOINTS
NEW METAL RAILING TO BE INSTALLED AND
POWER COATED .
1/2" EXPANSION JOINT
SLOPE
6"
TOOL JOINT
TOOL EDGE
1' - 0"
1/2" EXPANSION JOINT
NEW METAL RAILING
TO BE INSTALLED AND
POWDER COATED .
NEW 4" CONCRETE
PAVEMENT SLAB
EXISTING MASONRY
TO REMAIN
EXISTING STONE TO BE
CLEANED AND REPAIRED
EXISTING STONE BANDING
TO BE CLEANED AND 100%
REPOINTING OF ALL STONE
JOINTS
NEW CONCRETE STAIR
TO MATCH STONE IN
COLOR. V.I.F.
42" 1' - 0"
KEY JOINT OR
SLIP DOWELS
3"
MIN
REINFORCEMENT STEEL
1/2" EXP. JOINT
3' OR 4" POST
MORTAR CAP
12" DIAMETER HOLE
6" POST SLEEVE
CRUSHED GRAVEL IN
BOTTOM OF THE HOLE
CONCRETE AROUND
POST SLEEVE (PVC)
CRUSHED GRAVEL
BACKFILL
APPROVED POST BASE
WITH POST ANCHOR
GRADE
3' - 0"
POURED
CONCRETE PIER
AND FOOTING
NOTE:
1. POSTS MUST BE CENTERED ON FOOTINGS
2. FOOTINGS MUST BEAR ON SOLID GROUND
-4"
3 - #3 TIES
EQ. SPACED
#4 TYP
-2"
4 - #4
#3 TIE
SONOTUBE
SEE SHEET
C5/A-403
FOR DIA.
CL, TYP.
PLAN
SECTION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-509
CONCRETE DETAILS
HMPRKP
SCALE: 3/4" = 1'-0"B1
ELEVATION OF EXISTING EXTERIOR SOUTH STAIR
SCALE: 3/8" = 1'-0"D1
PLAN OF NEW SOUTH EXTERIOR STAIR
SCALE: 3/4" = 1'-0"D3
SECTION DETAIL OF NEW SOUTH EXTERIOR STAIR
SCALE: 3/4" = 1'-0"F1
ELEVATION OF EXISTING EXTERIOR NORTH STAIR
SCALE: 1/2" = 1'-0"B6
PLAN OF NEW NORTH EXTERIOR STAIR
SCALE: 3/4" = 1'-0"D6
SECTION DETAIL OF NEW NORTH EXTERIOR STAIR
SCALE: 3/4" = 1'-0"F6
RAILING POST EMBEDMENT DETAIL
SCALE: 3/4" = 1'-0"F8
TYPICAL POST DETAIL
SCALE: = 1'-0"3/4"
0 1 2 31
SCALE: = 1'-0"
0 2 42
1/2"SCALE: = 1'-0"3/8"
0 2 4 62
DOWNSPOUT
FLASHING
SPLASH BLOCK
1. ALL WORK SHALL BE COMPLETE AND OPERATIONAL.
2. ALL DIMENSIONS TO BE VERIFIED IN FIELD. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS PRIOR TO STARTING WORK.
3. PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY DEMOLITION AND/ OR INSTALLATION OF NEW WORK, AS REQUIRED TO MATCH ADJACENT SURFACES AND/ OR TO RECEIVE NEW SCHEDULED
FINISHES.
4. REMOVE ALL EXISTING CONSTRUCTIONS AND FINISHES NECESSARY FOR THE COMPLETION OF THE
WORK AS INDICATED.
5. CONTRACTOR SHALL INVESTIGATE EXISTING CONDITIONS PRIOR TO STARTING WORK. WHEN SUCH
ITEMS ARE SCHEDULED TO BE DEMOLISHED, SHORE UP SYSTEM PROPERLY PRIOR TO REMOVING
THEM. WHEN IN DOUBT, CONTACT ARCHITECT PRIOR TO REMOVING ANY ITEMS IN QUESTION.
6. NEW WORK TO MATCH EXISTING HISTORICAL LOOK OF GUTTER, DOWNSPOUTS, STRAPS AND ALL
ASSOCIATED ACCESSORIES IN KIND (COLOR, SHAPE, PROFILE TEXTURE, MATERIAL ETC.)
GENERAL NOTES:HOLE EA. SIDE
5/16 " X 1/8 " SLOTTED
SIZE AS SHOWN
ELSEWHERE
ELSEWHERE
SIZE AS SHOWN
DIA. BOLT IN
CHOR. SEE
DRILL FOR 1/4 "
LEAD EXP. AN-
NOTE.
LEAD WASHER
DOWNSPOUT & SHOE
.024" ALUM. OR .012"
FRONT, ALLOPTIONS
STAINLESS STEEL
DOWNSPOUT STRAPS
TO BE 48 oz. COLD
ROLLED BRASS, .060"
TO BE 16 oz. COPPER, ALUM. OR .050" STAIN-
SCREWS- 1 EA. SIDE &
FOR ALUM. OPTION)
LESS STL. (SEE SPECS.
BRASS, ALUM. OR
1/4 " DIA. X 5/8 " BOLT -
STAINLESS STEEL
#14 S.S. SHEET METAL
OUTLET TUBE
SOLDERED
FLANGE
GUTTER LINING
DOWNSPOUT
STRAP
AT 30" O.C.
GUTTER
BRASS BAR
DOWNSPOUT
BRACKET
AT 30" O.C.
BOLT W/ NUT
GUTTER-END
BASE FLASHING
4"M
IN.
6" MIN.
NOTE: STRAPS AND BRACKETS TO BE COMPATIBLE
REPAIR OR REPLACE COPPER
DOWNSPOUT ASSEMBLIES AS