S02- AMENDMENT 1 - 03 1200392 VA Bldg 20 ARCH 05 13 2021 Part 1.pdf
PDF 4 MB Posted
- Attached to
- Z2DZ-36C249-21-AP-3182 - 621-15-101 - Correct Admin Bldg. -20 Environment & Condition Deficiencies
- Solicitation number
- 36C24921B0014
About this file
This notice provides information about a forthcoming solicitation for construction services. The Department of Veterans Affairs seeks to correct environment and condition deficiencies at the Administration Building 20 at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. Work includes modifications, demolition, and replacement of finishes to modernize approximately 6,544 square feet of space for police staff offices, conference rooms, observation and interview rooms, evidence processing and storage, locker rooms, and support spaces. The estimated value is between $1 million and $5 million. The solicitation will be issued on October 20, 2021 and closed on November 20, 2021, following FAR Part 14.101 sealed bidding procedures. The procurement is reserved exclusively for Service-Disabled Veteran Owned Small Businesses. Questions must be submitted in writing by email with the project information in the subject line.
View the file
Other files
Show all 36
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A.F.F.
ACC. DR.
ADAAG
ACCESS.
ADJ.
ACOUST.
A.B.
ACT
ANOD.
A.C.
AL / ALUM.
L
APP.
APPROX.
ARCH.
AT / FP
AVG.
A.W.I.
B.H.M.I.
BM.
BLKG.
BD.
BTM.
BLDG.
CFCI
CH.
CPT.
CLG.
CLG. HT.
CTR.
CL
C. TO C.
C.T.
CLR.
C.O.
CLOS.
CO.
COL.
CONC.
CORR.
COTR
CMU
CONF.
CONST.
CONT.
CONTR.
C.J.
DET.
DIA.
DIM.
DISP.
DR.
DN.
D.S.
DESC.
DWG.
EA.
ELEC.
EL.
E.W.C.
E.R.D.
E.P.
ENGR.
EQUIP.
EQ.
EXIST.
EXP.
E.J. (EXP. JT.)
EXP. TO STRUCT.
EXT.
ETD
FAC.
FDC
FT.
F.E.
F.E.C.
F.H.C.
FIN.
F.P.
F.F.
FLR.
F.D.
FLUOR.
FV.
ABOVE FINISHED FLOOR
ACCESS DOOR / PANEL
AMERICAN WITH DISABILITIES
ACCESSIBILITY GUIDELINES
ACCESSORIES
ADJUST/ ADJUSTABLE
ACOUSTICAL
ANCHOR BOLT
ACOUSTICAL CEILING TILE
ANODIZED
AIR CONDITIONING
ALUMINUM
AND
ANGLE
APPROVED
APPROXIMATE
ARCHITECTURAL
AT
ANTI TERRORISM / FORCE PROTECTION
AVERAGE
ARCHITECTURAL WOODWORK INSTITUTE
BUILDER'S HARDWARE MANUFACTURER'S
ASSOCIATION, INC.
BEAM
BLOCKING
BOARD
BOTTOM
BUILDING
CONTRACTOR FURNISHED CONTRACTOR
INSTALLED
CHANNEL
CARPET
CEILING
CEILING HEIGHT
CENTER
CENTER LINE
CENTER TO CENTER
CERAMIC TILE
CLEAR
CLEANOUT
CLOSET
COMPANY
COLUMN
CONCRETE
CORRIDOR
CONTRACTING OFFICER'S TECHNICAL
REPRESENTATIVE
CONCRETE MASONRY UNIT
CONFERENCE
CONSTRUCTION
CONTINUOUS
CONTRACTOR
CONTROL JOINT
DETAIL
DIAMETER
DIMENSION
DISPENSER
DOOR
DOWN
DOWNSPOUT
DESCRIPTION
DRAWING
EACH
ELECTRICAL OR ELECTRIC
ELEVATION
ELECTRIC WATER COOLER
EMERGENCY ROOF DRAIN
EPOXY PAINT
ENGINEER
EQUIPMENT
EQUAL
EXISTING
EXPANSION / EXPOSED
EXPANSION JOINT
EXPOSED TO STRUCTURE
EXTERIOR
ESTIMATED TRAVEL DISTANCE
FACTORY
FIRE DEPARTMENT CONNECTION
FEET
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FIRE HOSE CABINET
FINISH
FLAT PAINT
FINISHED FLOOR
FLOOR
FLOOR DRAIN
FLUORESCENT
FIELD VERIFY
GA.
GALV.
G.B.F.
GC
GFCI
GFGI
G.L.
G.P.
GL.
GOVT.
GYP.
GYP. BD. (GWB)
HKS
HR.
HDW.
HGT.
H.
H.P.
H.M.
HORIZ.
H.V.A.C.
IN.
I.D.
INSUL.
INT.
JAN.
J.C.
JT.
JST.
K.P.
LAM.
LDG.
LAV.
L.H.
LHR
LT.
LTG.
LONG.
LVR.
L.P.
MGR.
MANUF.
MATL.
MAX.
MECH.
MTL.
M.W.P.
MIN.
MISC.
N.I.C.
NO. (#)
NTS
NFPA
O.C.
OFCI
OFGI
O.H.
OPNG.
OPP.
O.D.
OSHA
OVHD
PDU
PT
PR.
PNL.
PART.
PLAS.
PL
PLYWD.
LBS. OR #
PSF
PSI
P.M.J.F.
PRE-FAB.
Q.T.
RECEP.
REF.
REINF.
REQ'D.
REV.
RH
RHR
GAGE OR GAUGE
GALVANIZED
GYPSUM BOARD FURRING
GENERAL CONTRACTOR
GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GOVERNMENT FURNISHED
GOVERNMENT INSTALLED
GIRT LINE
GLOSSY PAINT
GLASS
GOVERNMENT
GYPSUM
GYPSUM BOARD
HOOKS
HANDRAIL
HARDWARE
HEIGHT
HIGH
HIGH POINT
HOLLOW METAL
HORIZONTAL
HEATING VENTILATION & AIR
CONDITIONING
INCH
INSIDE DIAMETER
INSULATION
INTERIOR
JANITOR
JANITOR'S CLOSET
JOINT
JOIST
KICK PLATE
LAMINATE
LANDING
LAVATORY
LEFT HAND
LEFT HAND REVERSE
LIGHT
LIGHTING
LONGITUDINAL
LOUVER
LOW POINT
MANAGER
MANUFACTURER
MATERIAL
MAXIMUM
MECHANICAL
METAL
METAL WALL PANEL
MINIMUM
MISCELLANEOUS
NOT IN CONTRACT
NUMBER
NOT TO SCALE
NATIONAL FIRE PROTECTION
ASSOCIATION
ON CENTER
OWNER FURNISHED
CONTRACTOR INSTALLED
OWNER FURNISHED
GOVERNMENT INSTALLED
OPPOSITE HAND
OPENING
OPPOSITE
OUTSIDE DIAMETER
OCCUPATIONAL SAFETY AND
HEALTH ACT
OVERHEAD
POWER DISTRIBUTION UNIT
PAINT
PAIR
PANEL
PARTITION
PLASTER OR PLASTIC
PLATE
PLYWOOD
POUNDS
POUNDS / SQUARE FOOT
POUNDS / SQUARE INCH
PRE-MOLDED JOINT FILLER
PREFABRICATED
QUARRY TILE
RECEPTIONIST
REFERENCE
REINFORCEMENT
REQUIRED
REVISIONS / REVISED
RIGHT HAND
RIGHT HAND REVERSE
RM.
R.O.
RB
SC
SCW
SCHED.
SECT.
S.G.P.
SSK
SHT. MET.
SIM.
STC
SPEC(S)
SFRM
SQ.
ST.
S.S.
STD.
STL.
STOR.
STRUCT.
SUSP.
TOIL. / TLT
TEL.
THK.
T'HOLD
TG
T/
TOB
TOC
T/C
TOS
T/W
TU
TYP.
U.L.
UNFIN
U.N.O.
VERT.
VEST.
VCT
VCB
W.
W/ W.C.
WCO
WD.
WDW.
W.M.P.
W/O W.R.G.B.
W.S.
W.R.O.
YD.
ROOM
ROUGH OPENING
RUBBER BASE
SEALED CONCRETE
SOLID CORE WOOD
SCHEDULE
SECTION
SEMI-GLOSS PAINT
SERVICE SINK
SHEET METAL
SIMILAR
SOUND TRANSMISSION CLASS
SPECIFICATION
SPRAYED FIRE RESISTIVE
MATERIAL
SQUARE
STAIN
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STRUCTURAL
SUSPENDED
TOILET
TELEPHONE
THICK
THRESHOLD
TEMPERED GLASS
TOP OF
TOP OF BEAM
TOP OF CONCRETE
TOP OF CURB
TOP OF STEEL
TOP OF WALL
TOUCH-UP
TYPICAL
UNDERWRITERS LABORATORIES
UNFINISHED
UNLESS NOTED OTHERWISE
VERTICAL
VESTIBULE
VINYL COMPOSITION TILE
VINYL COVE BASE
WIDTH
WITH
WATER CLOSET
WALL CLEAN OUT
WOOD
WINDOW
WIRE MESH PARTITION
WITHOUT
WATER RESISTANT GYPSUM
BOARD
WEATHERSTRIPPING
WINDOW ROUGH OPENING
YARD
ARCHITECTURAL ABBREVIATIONS
NOTE: NOT ALL ARCHITECTURAL
ABBREVIATIONS ARE USED
SHEET NAMING CONVENTION
A-001A
2 DIGIT SEQUENTIAL #
(01-99) (FIRST DIGIT
INDICATES PLAN
TYPE. SECOND DIGIT
INDICATES FLOOR)
1 DIGIT SHEET TYPE DESIGNATOR
0 - GENERAL
1 - PLANS
2 - ELEVATIONS
3 - SECTIONS
4 - ENLARGED PLANS
5 - DETAILS
6 - SCHEDULES AND DIAGRAMS
7 - VARIES
8 - VARIES
9 - 3D VIEWS (ISO, PERSPECTIVES)
2 DIGIT DISCIPLINE
DESIGNATOR
(IF ONLY ONE LETTER
IS USED, THE SECOND
LETTER IS REPLACED
WITH A DASH "-" AS A
PLACEHOLDER)**
1 DIGIT AREA
DESIGNATOR
(AREA DESIGNATOR
ONLY USED WHEN
PLANS ARE SUBDIVIDED
INTO AREAS.)
SYMBOLS:
SECTION NUMBER
DWG. NO. WHERE
SECTION IS DRAWN
A1
A-101
SIM
DETAIL NUMBER
DWG. NO. WHERE
SECTION IS DRAWN
DETAIL SECTION MARK
A1
A-101
SIM
WALL SECTION MARK
ELEVATION
NUMBER (TYP.)
DWG. NO. WHERE
ELEVATION IS DRAWN
A-101
INTERIOR ELEVATION MARK
DWG. NO. WHERE
DETAIL IS DRAWN
DETAIL
NUMBER (TYP.)
AREA COVERED
BY DETAIL
A-101
SIM
CALLOUT HEAD
ROOM TAG
ROOM
NAME
DOOR TAG
WINDOW &
LOUVER TAG
A
PARTITION TYPE
X
PARTITION
TYPE
KEYNOTE
TAG
CEILING HGT.
CEILING TYPE
1t 12'-0"
CEILING TAG
(TYPE & HEIGHT)
EQUIPMENT
TAG
1i
REVISION
TAG
NORTH ARROWS
N
DETAIL IDENTIFIER (MODULE LETTER AND NUMBER)
FLOOR PLANS, ELEVATIONS OR DETAIL VIEWS TITLE
A1
ELEVATIONS, DETAILS & CALLOUTS
SCALE: 1/8" = 1'-0"
PLAN SYMBOLS:
VIEW TITLES:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-001
ABBREVIATIONS & SYMBOLS
RAPJMC
REVISIONS DATE
1. BUILDING IS VACANT.
2. NOTE THAT THERE IS VERY LIMITED PARKING AND MATERIAL STAGING
AREAS ON THE CAMPUS. COR TO COORDINATE WITH VA PROJECT
MANAGER FOR REQUIRED SPACE AVAILABILITY AND ACCESS.
3. BASED ON THE 2006 SURVEY REPORT PREPARED BY E. ROBERTS
ALLEY & ASSOCIATES, INC., THE FIRST AND SECOND FLOOR CONTAINS
ASBESTOS. VERIFY IN FIELD.
4. NOTE THAT ALL PERSONNEL HANDLING HAZARDOUS MATERIALS SHALL
HAVE CLASS III ASBESTOS TRAINING AS DEFINED IN THE OCCUPATIONAL
SAFETY AND HEALTH ADMINISTRATION (OSHA) ASBESTOS STANDARD
(29 CFR 1926.1101).
5. HAZARDOUS MATERIALS ABATEMENT WITHIN THE AREAS OF
RENOVATION SHALL BE PERFORMED AS PART OF THIS CONTRACT
PRIOR TO THE START OF SELECTIVE DEMOLITION.
6. IT SHALL BE UNDERSTOOD BY ALL PARTIES THAT THE SCOPE OF
SERVICES PROVIDED BY ARCHITECT DOES NOT INCLUDE ANY SERVICES
RELATED TO THE DETERMINATION OF MATERIAL OR ITEMS SUSPECTED
OF CONTAINING HAZARDOUS MATERIALS. ARCHITECT IS NOT
RESPONSIBLE IN ANY WAY FOR SAFETY PRECAUTIONS, INCLUDING
MEASURES FOR THE PROTECTION OF THE CONTRACTOR OR SUB
CONTRACTORS, NOR FOR THE PROTECT OF GOVERNMENT EMPLOYEES
AND THE PUBLIC. SUCH RESPONSIBILITY FOR SAFETY PRECAUTIONS IS
AND SHALL REMAIN THAT OF THE GOVERNMENT AND THE
CONTRACTOR.
GENERAL PROJECT ACCESS NOTES:
1. BUILDING 20 IS A TWO STORY PLUS BASEMENT AND APPROXIMATELY
6,544 S.F. IT IS PRIMARILY OFFICE SPACE WITH ASSOCIATED
MECHANICAL SPACES, A BREAK ROOM, STORAGE AND RESTEROOMS.
INTERIOR WALLS ARE PLASTER AND SHEETROCK. FLOORING SYSTEMS
ARE A MIX OF FLOOR TILE, LINOLEUM AND CARPETING OVER
HARDWOOD FLOORING.
2. THE FIRST AND SECOND FLOORS ARE CONSTRUCTED OF WOOD. THE
INTERIOR OF THE BUILDING IS PREDOMINANTLY PLASTER, ALTHOUGH
THERE HAVE BEEN WALLS ADDED WHICH ARE FINISHED WITH GYPSUM
WALL BOARD.
GENERAL BUILDING INFORMATION:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
A-002
GENERAL AND STRUCTURAL NOTES
HMPRKP
1. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME
FAMILIAR WITH SITE CONDITIONS AS THEY MAY AFFECT
ARRYING OUT THE WORK AS DESCRIBED IN THESE CONTRCAT
DOCUMENTS. THE CONTRACTR SHALL INVESTIGATE, VERIFY,
AND BE RESPONSIBLE FOR ALL CONDITIONS OF PROJECT, AND
NOTIFY THE ARCHITECT OF ANY CONDITIONS THAT REQUIRE
MODIFICATION BEFORE PROCEEDING WITH THE WORK.
2. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS,
EQUIPMENT AND LABOR AND SERVICES NECESSRAY TO
COMPLETE THE WORK.
3. ALL SUBCONTRACTORS SHALL SUBMIT SHOP DRAWINGS AS
REQUIRED FOR APPROVAL PRIOR TO COMMENCING ANY WORK.
4. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
LOCATING AND PROTECTING ALL UTILITY LINES.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY
BRACING AND SHORING REQUIRED DURING CONSTRUCTION.
6. ALL WORK AND MATERIAL SHALL BE REGARDED AS NEW
UNLESS SPECIFICALLY INDICATED AS "EXISTING" ON THE
DRAWINGS AND DESCRIBED WITHIN THE SPECIFICATIONS.
7. ALL EXTERIOR WOOD SHALL BE PRESSURE TREATED.; ALL
WOOD INSIDE BUILDING ENVELOPE'S AIR AND/ OR RAIN BARRIER
SHALL BE FIRE RETARDANT TREATED.
GENERAL NOTES
STRUCTURAL STEEL:
1. STRUCTURAL STEEL FOR THIS PROJECT HAS BEEN DESIGNED IN ACCORDANCE WITH THE FIFTEENTH EDITION OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) "STEEL CONSTRUCTION MANUAL", USING LOAD AND RESISTANCE FACTOR DESIGN.
2. STRUCTURAL STEEL SHALL COMPLY WITH THE FOLLOWING SPECIFICATIONS:
a. STRUCTURAL STEEL WIDE FLANGE SHAPES - ASTM A992, Fy = 50 ksi
b. OTHER STRUCTURAL STEEL SHAPES, PLATES, AND BARS - ASTM A36, Fy = 36 ksi
c. COLD-FORMED STRUCTURAL STEEL TUBING - ASTM A500, GRADE B, Fy = 42 ksi
d. STEEL PIPE - ASTM A53, GRADE B, TYPE E OR S, Fy = 35 ksi
e. ANCHOR RODS - ASTM F1554, Fy = 36 ksi
3. WELDING SHALL BE IN ACCORDANCE WITH AWS D.1, "STRUCTURAL WELDING CODE - STEEL", LATEST EDITION. WELD ELECTRODES SHALL BE
E70XX. PROVIDE ?" CONTINUOUS FILLET WELDS UNLESS NOTED OTHERWISE.
4. EXPOSED EXTERIOR METAL INCLUDING ALL EXTERIOR METAL FABRICATIONS SHALL BE SHOP FABRICATED, PRIMED, AND PAINTED.
5. UNLESS NOTED OTHERWISE, ALL BEAM SHEAR CONNECTIONS SHALL BE MADE USING ?"∅ A325 BOLTS, BEARING TYPE WITH THREADS EXCLUDED. ALL GRAVITY ONLY BEAMS SHALL HAVE SIMPLE SHEAR CONNECTIONS DESIGNED TO SUPPORT 1/2 THE TOTAL FACTORED UNIFORM LOAD FOR THE SUPPORTED BEAM, ITS SPAN, AND ITS GRADE OF STEEL AS SPECIFIED IN AISC LRFD.
CAST-IN-PLACE CONCRETE:
1. CAST-IN-PLACE CONCRETE FOR THIS PROJECT SHALL COMPLY WITH THE AMERICAN CONCRETE INSTITUTE (ACI) "BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE AND COMMENTARY" ACI 318-19 AND ACI 318R-19.
2. REFERENCE PROJECT SPECIFICATION SECTION 033000 "CAST-IN-PLACE CONCRETE".
3. CONCRETE SHALL HAVE THE FOLLOWING PROPERTIES:
(SEE SPECIFICATION SECTION 033000 FOR ADDITIONAL REQUIREMENTS)
4. AN INTENTIONALLY ROUGHENED SURFACE MAY BE USED INSTEAD OF A CONTINUOUS SHEAR KEY AT ALL HORIZONTAL CONSTRUCTION JOINTS.
5. ALL EXPOSED CONCRETE EDGES SHALL HAVE 3/4" CHAMFER, WHETHER SPECIFICALLY NOTED OR NOT.
6. TYPICAL SLAB FINISH SHALL BE BROOM FINISH FOR EXTERIOR SLABS AND INTERIOR WET SLABS AND STEEL TROWEL FINISH FOR INTERIOR DRY
SLABS.
7. ALL ANCHOR RODS SHALL BE BLACK OR HOT DIPPED GALVANIZED AS NOTED ON DESIGN DRAWINGS.
8. CONCRETE FORM WORK SHALL COMPLY WITH ACI 347, LATEST EDITION. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN OF ALL
FORMWORK.
9. DURING AND IMMEDIATELY AFTER PLACING, CONCRETE SHALL BE THOROUGHLY COMPACTED BY SPADING OR MECHANICAL VIBRATING TO
PROVIDE DENSE CONCRETE FREE OF HONEY COMBING.
10. DIRECTLY AFTER FORMS HAVE BEEN REMOVED, ALL EXPOSED TIE WIRES AND STAPLED ENDS SHALL BE REMOVED FROM CONCRETE SURFACES TO BE EXPOSED. CUT TIES FLUSH WITH FINISHED SURFACES FOR ALL OTHER CONCRETE. RUB SMOOTH OR CUT OFF FINS AND ROUGH PLACES. REMOVE ALL LOOSE CONCRETE AND OTHER IRREGULARITIES. PATCH AND FILL VOIDS WITH BONDING AGENT AS REQUIRED.
CONCRETE REINFORCEMENT:
1. REINFORCING STEEL SHALL CONFORM TO ASTM A615 SUPPLEMENT SI, GRADE 60, OF DOMESTIC MANUFACTURER.
2. WELDED WIRE REINFORCEMENT SHALL CONFORM TO ASTM A185. WELDED WIRE REINFORCEMENT SHALL BE SUPPLIED IN FLAT SHEETS ONLY.
LAP 9" MINIMUM.
3. REINFORCEMENT SHALL BE FABRICATED TO SHAPES AND DIMENSIONS SHOWN AND SHALL CONFORM TO THE REQUIREMENTS OF CRSI AND ACI 318. REINFORCEMENT SHALL BE COLD BENT UNLESS OTHERWISE AUTHORIZED. BENDING MAY BE ACCOMPLISHED IN THE FIELD OR AT THE
MILL. BARS SHALL NOT BE BENT AFTER EMBEDDED IN CONCRETE.
4. REINFORCEMENT SHALL BE FREE FROM LOOSE RUST AND SCALE, DIRT, OIL, OR OTHER DELETERIOUS COATING THAT COULD REDUCE BOND
WITH THE CONCRETE.
5. NO SPLICES OF REINFORCEMENT SHALL BE PERMITTED EXCEPT AS DETAILED OR AUTHORIZED. MAKE BARS CONTINUOUS AROUND CORNERS WITH CORNER BARS. WHERE PERMITTED, SPLICES MADE BY CONTACT LAPS SHALL BE CLASS "B" TENSION LAPS.
6. TENSION AND COMPRESSION REINFORCEMENT SPLICES IN CONCRETE SHALL BE MADE AS FOLLOWS:
#4 BARS - 28"
#5 BARS - 35"
#6 BARS - 46"
#7 BARS - 63"
7. WHERE HOOKS ARE SHOWN, PROVIDE STANDARD 90° HOOKS IN ACCORDANCE WITH CRSI AND ACI 318, UNLESS NOTED OTHERWISE.
8. WHERE REQUIRED, PROVIDE DOWELS TO MATCH SIZE AND SPACING OF VERTICAL REINFORCING FROM FOUNDATION. DOWELS SHALL HAVE
STANDARD 90° HOOKS.
9. MINIMUM CONCRETE REINFORCING COVER REQUIREMENTS:
a. CONCRETE CAST AGAINST EARTH:
b. FORMED CONCRETE EXPOSED TO EARTH OR WEATHER:
WALLS, SLABS:
#6 BAR AND LARGER
#5 BAR AND SMALLER
c. FORMED CONCRETE NOT EXPOSED TO WEATHER OR IN
CONTACT WITH GROUND:
WALLS, SLABS:
#11 BAR AND SMALLER
10. ALL REINFORCING STEEL AND EMBEDDED ITEMS SUCH AS ANCHOR RODS AND WELD PLATES SHALL BE PLACED TO PREVENT DISPLACEMENT
BEYOND PERMITTED TOLERANCES.
11. DETAIL BARS IN ACCORDANCE WITH "ACI DETAILING MANUAL-2004", PUBLICATION SP-66, ACI 318, AND ACI 315, OR LATEST EDITIONS.
12. PROVIDE ACCESSORIES NECESSARY TO PROPERLY SUPPORT REINFORCING AT POSITIONS SHOWN ON PLANS.
STRUCTURAL NOTES
WEIGHT STRENGTH @ 28 DAYS AIR CONTENT
NORMAL WEIGHT 3000PSI 5%
REVISIONS DATE
UP
GENERAL
STORAGE
STORAGE
CLOSET
AD901B1
AD901 B4
AD901 B7
AD901 D1
NOTE: EXISTING STEAM
LINETO BE CUT AND
CAPPED OUTSIDE OF
BLDG.
NOTE: DO NOT DEMO
RED CONDUIT WITH
FIBER OPTIC FOR FIRE
ALARM SYSTEM.
EXISTING LOUVER TO REMAIN
EXISTING
WINDOW
TO REMAIN
CONTRACTOR TO
TO CREATE 8"x6" OPENING
IN EXISTING WALL FOR NEW
HIGH WALL EXHAUST GRILL.
PROVIDE 1/4" THICK LINTEL AT
OPENING WITH MIN. 2" BEARING ON
EACH SIDE.
CONTRACTOR TO
TO CREATE 8"x6" OPENING
IN EXISTING WALL FOR NEW
HIGH WALL EXHAUST GRILL.
PROVIDE 1/4" THICK LINTEL AT
OPENING WITH MIN. 2" BEARING ON
EACH SIDE.
PROVIDE 24"x 24"
OPENING WITH ACCESS
DOOR FOR PLUMBING
VALVE ACCESS. PLACE
1/4" THICK LINTEL AT
OPENING.
CRAWL SPACE
(PARTIALLY UNEXCAVATED)
CRAWL SPACE
(PARTIALLY UNEXCAVATED)
CRAWL SPACE
(PARTIALLY UNEXCAVATED)
FILL IN UP TO CONC. FL. ABOVE
CRAWL SPACE
(PARTIALLY UNEXCAVATED)
1. DEMOLITION WORK SHALL BE EXCUTED IN CONFORMANCE WITH
ALL CODES AND ORDINANCES.
2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY
ARCHITECT OF ANY DISCREPENCIES.
3. LIMIT REMOVAL AND DEMOLITION TO THAT SPECIFICALLY CALLED
FOR IN THE INSTALLATION OF NEW WORK. PROTECT ALL
EXISTING ITEMS TO REMAIN FROM DAMAGE. NEW WORK SHALL
ALIGN WITH AND MATCH EXISTING WORK EXCEPT WHERE
OTHERWISE DIMENSIONED OR DETAILED.
4. REMOVE ALL EXISTING CONSTRUCTIONS AND FINISHES
NECESSARY FOR THE COMPLETION OF THE WORK AS INDICATED.
INCLUDING BUT NOT LIMITED TO ITEMS SHOWN ON THE PLANS
WITH DASHED LINES NECESSARY DISCONNECTS AND
ALTERATIONS TO EXISTING MECHANICAL AND ELECTRICAL
SYSTEMS SHALL BE INCLUDED.
5. WHERE CONTRACTOR IS DESIGNATED TO MAKE REMOVALS,
DISPOSITION OF MATERIALS IS THE RESPONSIBILITY OF THE
CONTRACTOR. VERIFY WITH OWNER, THE DISPOSITION AND
REMOVAL OF ANY COMPONENTS OF SALVAGEABLE VALUE.
6. EXISTING SURFACES SHALL BE PREPARED TO RECEIVE NEW
SCHEDULED FINISHES BY GRINDING, SCRAPING, FILLING,
PATCHING, LEVELING, ETC. AS REQUIRED (REFER TO INTERIOR
DESIGN DOCUMENTS).
7. REMOVE ONLY NON-LOAD BEARING CONSTRICTION AND
PARTITIONS. CONTRACTOR TO VERIFY, PRIOR TO REMOVAL, THAT
NO STRUCTURAL COMPONENTS, I.E. BEARING WALLS, BEAMS,
HEADERS, ETC. CONTACT THE ARCHITECT PRIOR TO REMOVAL OF
ANY CONSTRUCTION IN QUESTION OR DEVIATING FROM THE
DESIGN INTENT.
8. ALL STRUCTURAL SYSTEMS SHALL BE MAINTAINED. THE
CONTRACTOR SHALL BRACE ALL EXISTING STRUCTURES AND ALL
STRUCTRURAL ELEMENTS NECESSARY DURING DEMOLITION.
9. PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY
DEMOLITION AND/ OR INSTALLATION OF NEW WORK AND/ OR
UTILITIES, AS REQUIRED TO MATCH ADJACENT SURFACES AND/
OR TO RECEIVE NEW SCHEDULED FINISHES.
10. WHERE DEMOLITION OR RELATED WORK LEAVES FLOOR
SURFACES WITH IMPERFECTIONS OR NOT LEVEL TO
TOLERANCES SPECIFIED FOR NEW WORK,
PROVIDE SELFLEVELING UNDERLAYMENT.
11. ALL PENETRATIONS OF EXISTING FLOORS AND FIRE RATED
WALL OR SMOKE PARTITIONS SHALL BE PATCHED & REPAIRED
(EXTEND, RESTORE, AND/OR CLOSE OPENING) AS REQUIRED TO
MAINTAIN THE EXISTING FIRE RATING.
12. VERIFY MATCH OF NEW FINISH MATERIALS TO EXISTING IN
COLOR TEXTURE, THICKNESS, CUT, ETC. TO THE STANDARD OF
PRIOR TO INSTALLATIONS.
13. CONTRACTOR IS RESPONSIBLE FOR DEMOLISHING AND
REMOVING ALL MATERIALS FROM PREMISES IN ORDER TO
ACCOMPLISH THE SCOPE OF THE NEW WORK.KEEP PREMISES
CLEAN AT ALLL TIMES ENSURING THAT THERE ARE NO LOOSE
MATERIAS OR ITEMS WHICH MAY CAUSE INJURY.
14. HAZARDOUS MATERIALS: IT IS NOT EXPECTEDTED THAT
HAZARDOUS MATERIALS WILL BE ENCOUNTEERED IN THE WORK.
IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS
MATERIALS ARE ENCOUNTERED, DO NOT DISTURB AND
IMMEDIATELY NOTIFY THE OWNER.
DEMOLITION NOTES:
DEMOLITION PLAN LEGEND
EXISTING STAIRCASE TREADS AND RISERS TO
BE REMOVED AND REPLACED, SEE SHEET A-401.
EXISTING CMU AND / OR STUD WALLS /
PARTITIONS TO BE DEMOLISHED
EXISTING DOOR & DOOR FRAME
ACCESSORIES TO REMAIN (B)
EXISTING DOOR, FRAME AND
ACCESSORIES TO BE DEMOLISHED
EXISTING WINDOW SYSTEM AND
ACCESSORIES TO REMAIN
EXISTING WINDOW, FRAME AND
ACCESSORIES TO BE DEMOLISHED
EXISTING WALLS / PARTITIONS TO REMAIN
PLAN LEGEND
AREA OF NO ARCHITECTURAL WORK
1. REFER TO G-002 FOR GENERAL PROJECT NOTES.
2. REFER TO A-001 FOR GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
SHEET NOTES:
3. SEE SHEET A-501 FOR PARTITION TYPES AND DETAILS.
4. SEE SHEET A-601 FOR DOOR SCHEDULE, TYPES, AND FRAMES.
5. SEE SHEET A-602 FOR WINDOW SCHEDULE AND DETAILS.
6. CEILINGS HEIGHT AT 8'-5" UNLESS NOTED OTHERWISE.
PROVIDE OPENING IN MASONRY WALL FOR ACCESS
PANEL(FIXED).
REMOVE EXISTING PIPE WITH ASBESTOS.
SEAL EXISTING ARC OPENING INMASONRY WALL WITH
ACCESS PANEL (FIXED).
REPAIR, PATCH AND SEAL EXISTING OPENING AND SEAL
WITH ACCESS PANEL (LATCH). SEE DETAILS.
REMOVE EXISTING ELECTRICAL PANEL.
EXISTING COLUMN TO REMAIN. CLEAN AND PAINT TO
MATCH SURROUNDING WALLS.
RESTORE EXISTING STAIRCASE TREADS AND INSTALL
NEW RAILINGS, SEE SHEET A-401 DETAILS.
REMOVE EXISTING CONSTRUCTION (INCLUDING DOOR,
FRAME AN WALLS)
REMOVE EXISTING DOOR AND FRAME TO ACCOMMODATE
NEW DOOR.
PATCH AS REQUIRED TO MATCH ADJACENT MATERIAL IN
KIND (ALL CONSTRUCTIONS TO REMAIN).
REMOVE EXSTING WINDOWS AND INFILL OPENING TO
MATCH AJACENT MATERIAL IN KIND.
KEYNOTES:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
AD100
BASEMENT DEMOLITION PLAN
RAPJMC
SCALE: 3/8" = 1'-0"F1
BASEMENT DEMOLITION PLAN
SCALE: = 1'-0"3/8"
0 2 4 62
DN
OFFICE
TYP
TYP
UP
DN
10 10
TYP
OFFICE
STORAGE
TOILET
107106
COPY RM
OFFICE
OFFICE
OFFICE
HSK
OFFICE
OFFICE
OFFICE
RECEPTION
OFFICE
OFFICE
STORAGE
EQUIP RM
101A
CORRIDOR
LOBBY
CORRIDOR CORRIDOR
AD901 D7
AD901
F1
AD901
F4
IG201
C8
DEMO EXISTING DOOR AND WALL
TO EXPAND OPENING SIZE
4' - 5" 7' - 9" 3' - 4" 5' - 11" 3' - 4" 0' - 7"
1. REFER TO G-002 FOR GENERAL PROJECT NOTES.
2. REFER TO A-001 FOR GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS.
SHEET NOTES:
3. SEE SHEET A-501 FOR PARTITION TYPES AND DETAILS.
4. SEE SHEET A-601 FOR DOOR SCHEDULE, TYPES, AND FRAMES.
5. SEE SHEET A-602 FOR WINDOW SCHEDULE AND DETAILS.
6. CEILINGS HEIGHT AT 8'-5" UNLESS NOTED OTHERWISE.
DEMOLITION PLAN LEGEND
EXISTING STAIRCASE TREADS AND RISERS TO
BE REMOVED AND REPLACED, SEE SHEET A-401.
EXISTING CMU AND / OR STUD WALLS /
PARTITIONS TO BE DEMOLISHED
EXISTING DOOR & DOOR FRAME
ACCESSORIES TO REMAIN (B)
EXISTING DOOR, FRAME AND
ACCESSORIES TO BE DEMOLISHED
EXISTING WINDOW SYSTEM AND
ACCESSORIES TO REMAIN
EXISTING WINDOW, FRAME AND
ACCESSORIES TO BE DEMOLISHED
EXISTING WALLS / PARTITIONS TO REMAIN
PATCH AS REQUIRED TO MATCH ADJACENT CONSTRUCTION
IN KIND WHERE ALL CONSTRUCTIONS TO REMAIN.
REMOVE AND REPLCE EXISTING ELECTRICAL PANEL.
REMOVE AND REPLACE EXISTING WINDOW.
REMOVE DOOR AND FRAME TO ACCOMMODATE NEW DOOR.
REMOVE EXISTING WINDOW AND PORTION OF EXTERIOR
WALL TO ACCOMMODATE NEW 3'-0" DOOR.
DEMOLISH EXISTING EXTERIOR RAMP.
CLEAN AND PAINT EXISTING RAILING.
REMOVE DOOR. PATCH AND INFILL OPENING TO MATCH
EXISTING ADJACENT CONSTRUCTION.
REMOVE, AND RESTORE DOOR FOR FUTURE USE.
REMOVE PLUMBING FIXTURES.
REMOVE DRINKING FOUNTAIN.
RESTORE EXISTING STAIRCASE AND INSTALL NEW
RAILINGS, SEE SHEET A-402 FOR DETAILS.
REMOVE AND SALVAGE ARCH TO BE USED AS INDICATED
ON IG201
KEYNOTES:
1. DEMOLITION WORK SHALL BE EXCUTED IN CONFORMANCE WITH
ALL CODES AND ORDINANCES.
2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY
ARCHITECT OF ANY DISCREPENCIES.
3. LIMIT REMOVAL AND DEMOLITION TO THAT SPECIFICALLY CALLED
FOR IN THE INSTALLATION OF NEW WORK. PROTECT ALL
EXISTING ITEMS TO REMAIN FROM DAMAGE. NEW WORK SHALL
ALIGN WITH AND MATCH EXISTING WORK EXCEPT WHERE
OTHERWISE DIMENSIONED OR DETAILED.
4. REMOVE ALL EXISTING CONSTRUCTIONS AND FINISHES
NECESSARY FOR THE COMPLETION OF THE WORK AS INDICATED.
INCLUDING BUT NOT LIMITED TO ITEMS SHOWN ON THE PLANS
WITH DASHED LINES NECESSARY DISCONNECTS AND
ALTERATIONS TO EXISTING MECHANICAL AND ELECTRICAL
SYSTEMS SHALL BE INCLUDED.
5. WHERE CONTRACTOR IS DESIGNATED TO MAKE REMOVALS,
DISPOSITION OF MATERIALS IS THE RESPONSIBILITY OF THE
CONTRACTOR. VERIFY WITH OWNER, THE DISPOSITION AND
REMOVAL OF ANY COMPONENTS OF SALVAGEABLE VALUE.
6. EXISTING SURFACES SHALL BE PREPARED TO RECEIVE NEW
SCHEDULED FINISHES BY GRINDING, SCRAPING, FILLING,
PATCHING, LEVELING, ETC. AS REQUIRED (REFER TO INTERIOR
DESIGN DOCUMENTS).
7. REMOVE ONLY NON-LOAD BEARING CONSTRICTION AND
PARTITIONS. CONTRACTOR TO VERIFY, PRIOR TO REMOVAL, THAT
NO STRUCTURAL COMPONENTS, I.E. BEARING WALLS, BEAMS,
HEADERS, ETC. CONTACT THE ARCHITECT PRIOR TO REMOVAL OF
ANY CONSTRUCTION IN QUESTION OR DEVIATING FROM THE
DESIGN INTENT.
8. ALL STRUCTURAL SYSTEMS SHALL BE MAINTAINED. THE
CONTRACTOR SHALL BRACE ALL EXISTING STRUCTURES AND ALL
STRUCTRURAL ELEMENTS NECESSARY DURING DEMOLITION.
9. PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY
DEMOLITION AND/ OR INSTALLATION OF NEW WORK AND/ OR
UTILITIES, AS REQUIRED TO MATCH ADJACENT SURFACES AND/
OR TO RECEIVE NEW SCHEDULED FINISHES.
10. WHERE DEMOLITION OR RELATED WORK LEAVES FLOOR
SURFACES WITH IMPERFECTIONS OR NOT LEVEL TO
TOLERANCES SPECIFIED FOR NEW WORK,
PROVIDE SELFLEVELING UNDERLAYMENT.
11. ALL PENETRATIONS OF EXISTING FLOORS AND FIRE RATED
WALL OR SMOKE PARTITIONS SHALL BE PATCHED & REPAIRED
(EXTEND, RESTORE, AND/OR CLOSE OPENING) AS REQUIRED TO
MAINTAIN THE EXISTING FIRE RATING.
12. VERIFY MATCH OF NEW FINISH MATERIALS TO EXISTING IN
COLOR TEXTURE, THICKNESS, CUT, ETC. TO THE STANDARD OF
PRIOR TO INSTALLATIONS.
13. CONTRACTOR IS RESPONSIBLE FOR DEMOLISHING AND
REMOVING ALL MATERIALS FROM PREMISES IN ORDER TO
ACCOMPLISH THE SCOPE OF THE NEW WORK.KEEP PREMISES
CLEAN AT ALLL TIMES ENSURING THAT THERE ARE NO LOOSE
MATERIAS OR ITEMS WHICH MAY CAUSE INJURY.
14. HAZARDOUS MATERIALS: IT IS NOT EXPECTEDTED THAT
HAZARDOUS MATERIALS WILL BE ENCOUNTEERED IN THE WORK.
IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS
MATERIALS ARE ENCOUNTERED, DO NOT DISTURB AND
IMMEDIATELY NOTIFY THE OWNER.
DEMOLITION NOTES:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
AD101
FIRST FLOOR DEMOLITION PLAN
RAPJMC
SCALE: 3/8" = 1'-0"F1
FIRST FLOOR DEMOLITION PLAN
SCALE: = 1'-0"3/8"
0 2 4 62
TYP
TYP
OFFICE
CLOSET
204A
CONFERENCE RM
KITCHEN
203A
OFFICE
CLOSET
CORRIDOR
LOBBY
CORRIDOR
STORAGE
TOILET
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MECH RM
HSK
AD901 D4
3' - 4"
0' - 5"
1. DEMOLITION WORK SHALL BE EXCUTED IN CONFORMANCE WITH
ALL CODES AND ORDINANCES.
2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY
ARCHITECT OF ANY DISCREPENCIES.
3. LIMIT REMOVAL AND DEMOLITION TO THAT SPECIFICALLY CALLED
FOR IN THE INSTALLATION OF NEW WORK. PROTECT ALL
EXISTING ITEMS TO REMAIN FROM DAMAGE. NEW WORK SHALL
ALIGN WITH AND MATCH EXISTING WORK EXCEPT WHERE
OTHERWISE DIMENSIONED OR DETAILED.
4. REMOVE ALL EXISTING CONSTRUCTIONS AND FINISHES
NECESSARY FOR THE COMPLETION OF THE WORK AS INDICATED.
INCLUDING BUT NOT LIMITED TO ITEMS SHOWN ON THE PLANS
WITH DASHED LINES NECESSARY DISCONNECTS AND
ALTERATIONS TO EXISTING MECHANICAL AND ELECTRICAL
SYSTEMS SHALL BE INCLUDED.
5. WHERE CONTRACTOR IS DESIGNATED TO MAKE REMOVALS,
DISPOSITION OF MATERIALS IS THE RESPONSIBILITY OF THE
CONTRACTOR. VERIFY WITH OWNER, THE DISPOSITION AND
REMOVAL OF ANY COMPONENTS OF SALVAGEABLE VALUE.
6. EXISTING SURFACES SHALL BE PREPARED TO RECEIVE NEW
SCHEDULED FINISHES BY GRINDING, SCRAPING, FILLING,
PATCHING, LEVELING, ETC. AS REQUIRED (REFER TO INTERIOR
DESIGN DOCUMENTS).
7. REMOVE ONLY NON-LOAD BEARING CONSTRICTION AND
PARTITIONS. CONTRACTOR TO VERIFY, PRIOR TO REMOVAL, THAT
NO STRUCTURAL COMPONENTS, I.E. BEARING WALLS, BEAMS,
HEADERS, ETC. CONTACT THE ARCHITECT PRIOR TO REMOVAL OF
ANY CONSTRUCTION IN QUESTION OR DEVIATING FROM THE
DESIGN INTENT.
8. ALL STRUCTURAL SYSTEMS SHALL BE MAINTAINED. THE
CONTRACTOR SHALL BRACE ALL EXISTING STRUCTURES AND ALL
STRUCTRURAL ELEMENTS NECESSARY DURING DEMOLITION.
9. PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED BY
DEMOLITION AND/ OR INSTALLATION OF NEW WORK AND/ OR
UTILITIES, AS REQUIRED TO MATCH ADJACENT SURFACES AND/
OR TO RECEIVE NEW SCHEDULED FINISHES.
10. WHERE DEMOLITION OR RELATED WORK LEAVES FLOOR
SURFACES WITH IMPERFECTIONS OR NOT LEVEL TO
TOLERANCES SPECIFIED FOR NEW WORK,
PROVIDE SELFLEVELING UNDERLAYMENT.
11. ALL PENETRATIONS OF EXISTING FLOORS AND FIRE RATED
WALL OR SMOKE PARTITIONS SHALL BE PATCHED & REPAIRED
(EXTEND, RESTORE, AND/OR CLOSE OPENING) AS REQUIRED TO
MAINTAIN THE EXISTING FIRE RATING.
12. VERIFY MATCH OF NEW FINISH MATERIALS TO EXISTING IN
COLOR TEXTURE, THICKNESS, CUT, ETC. TO THE STANDARD OF
PRIOR TO INSTALLATIONS.
13. CONTRACTOR IS RESPONSIBLE FOR DEMOLISHING AND
REMOVING ALL MATERIALS FROM PREMISES IN ORDER TO
ACCOMPLISH THE SCOPE OF THE NEW WORK.KEEP PREMISES
CLEAN AT ALLL TIMES ENSURING THAT THERE ARE NO LOOSE
MATERIAS OR ITEMS WHICH MAY CAUSE INJURY.
14. HAZARDOUS MATERIALS: IT IS NOT EXPECTEDTED THAT
HAZARDOUS MATERIALS WILL BE ENCOUNTEERED IN THE WORK.
IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS
MATERIALS ARE ENCOUNTERED, DO NOT DISTURB AND
IMMEDIATELY NOTIFY THE OWNER.
DEMOLITION NOTES:
DEMOLITION PLAN LEGEND
EXISTING STAIRCASE TREADS AND RISERS TO
BE REMOVED AND REPLACED, SEE SHEET A-401.
EXISTING CMU AND / OR STUD WALLS /
PARTITIONS TO BE DEMOLISHED
EXISTING DOOR & DOOR FRAME
ACCESSORIES TO REMAIN (B)
EXISTING DOOR, FRAME AND
ACCESSORIES TO BE DEMOLISHED
EXISTING WINDOW SYSTEM AND
ACCESSORIES TO REMAIN
EXISTING WINDOW, FRAME AND
ACCESSORIES TO BE DEMOLISHED
EXISTING WALLS / PARTITIONS TO REMAIN
PATCH AS REQUIRED TO MATCH ADJACENT
CONSTRUCTION IN KIND WHERE ALL CONSTRUCTIONS TO
REMAIN.
REMOVE AND REPLACE EXISTING ELECTRICAL PANEL.
REMOVE AND REPLACE EXISTING WINDOWS.
REMOVE EXISTING WINDOW AND PORTION OF EXTERIOR
WALL TO ACCOMMODATE NEW 3'-0" DOOR.
REMOVE, RESTORE AND MODIFY THE EXISTING STAIR
HANDRAIL. NEW HANDRAIL SHALL BE 42" ABOVE FINISHED
FLOOR.
REMOVE EXISTING PLUMBING FIXTURES.
REMOVE MILLWORK.
DEMOLISH EXISTING LOUVER AND REPLACE WITH NEW
WINDOW. SEE WINDOW SCHEDULE.
REMOVE FOLDING PARTITION.
KEYNOTES:
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
AD102
SECOND FLOOR DEMOLITION PLAN
RAPJMC
SCALE: 3/8" = 1'-0"F1
SECOND FLOOR DEMOLITION PLAN
SCALE: = 1'-0"3/8"
AD901F7
DEMOLITION PLAN LEGEND
EXISTING STAIRCASE TREADS AND RISERS TO
BE REMOVED AND REPLACED, SEE SHEET A-401.
EXISTING CMU AND / OR STUD WALLS /
PARTITIONS TO BE DEMOLISHED
EXISTING DOOR & DOOR FRAME
ACCESSORIES TO REMAIN (B)
EXISTING DOOR, FRAME AND
ACCESSORIES TO BE DEMOLISHED
EXISTING WINDOW SYSTEM AND
ACCESSORIES TO REMAIN
EXISTING WINDOW, FRAME AND
ACCESSORIES TO BE DEMOLISHED
EXISTING WALLS / PARTITIONS TO REMAIN
DEMOLITION NOTES:
1. DEMOLITION WORK SHALL BE EXCUTED IN
CONFORMANCE WITH ALL CODES AND ORDINANCES.
2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS
AND NOTIFY ARCHITECT OF ANY DISCREPENCIES.
3. LIMIT REMOVAL AND DEMOLITION TO THAT
SPECIFICALLY CALLED FOR IN THE INSTALLATION OF
NEW WORK. PROTECT ALL EXISTING ITEMS TO REMAIN
FROM DAMAGE. NEW WORK SHALL ALIGN WITH AND
MATCH EXISTING WORK EXCEPT WHERE OTHERWISE
DIMENSIONED OR DETAILED.
4. REMOVE ALL EXISTING CONSTRUCTIONS AND FINISHES
NECESSARY FOR THE COMPLETION OF THE WORK AS
INDICATED. INCLUDING BUT NOT LIMITED TO ITEMS
SHOWN ON THE PLANS WITH DASHED LINES NECESSARY
DISCONNECTS AND ALTERATIONS TO EXISTING
MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE
INCLUDED.
5. WHERE CONTRACTOR IS DESIGNATED TO MAKE
REMOVALS, DISPOSITION OF MATERIALS IS THE
RESPONSIBILITY OF THE CONTRACTOR. VERIFY WITH
OWNER, THE DISPOSITION AND REMOVAL OF ANY
COMPONENTS OF SALVAGEABLE VALUE.
6. EXISTING SURFACES SHALL BE PREPARED TO RECEIVE
NEW SCHEDULED FINISHES BY GRINDING, SCRAPING,
FILLING, PATCHING, LEVELING, ETC. AS REQUIRED
(REFER TO INTERIOR DESIGN DOCUMENTS).
7. REMOVE ONLY NON-LOAD BEARING CONSTRICTION AND
PARTITIONS. CONTRACTOR TO VERIFY, PRIOR TO
REMOVAL, THAT NO STRUCTURAL COMPONENTS, I.E.
BEARING WALLS, BEAMS, HEADERS, ETC. CONTACT THE
ARCHITECT PRIOR TO REMOVAL OF ANY CONSTRUCTION
IN QUESTION OR DEVIATING FROM THE DESIGN INTENT.
8. ALL STRUCTURAL SYSTEMS SHALL BE MAINTAINED. THE
CONTRACTOR SHALL BRACE ALL EXISTING STRUCTURES
AND ALL STRUCTRURAL ELEMENTS NECESSARY DURING
DEMOLITION.
9. PATCH AND REPAIR ALL EXISTING SURFACES DAMAGED
BY DEMOLITION AND/ OR INSTALLATION OF NEW WORK
AMD/ OR UTILITIES, AS REQUIRED TO MATCH ADJACENT
SURFACES AND/ OR TO RECEIVE NEW SCHEDULED
FINISHES.
10. WHERE DEMOLITION OR RELATED WORK LEAVES
FLOOR SURFACES WITH IMPERFECTIONS OR NOT LEVEL
TO TOLERANCES SPECIFIED FOR NEW WORK,
PROVIDE SELFLEVELING UNDERLAYMENT.
11. ALL PENETRATIONS OF EXISTING FLOORS AND FIRE
RATED WALL OR SMOKE PARTITIONS SHALL BE PATCHED
& REPAIRED (EXTEND, RESTORE, AND/OR CLOSE
OPENING) AS REQUIRED TO MAINTAIN THE EXISTING FIRE
RATING.
12. VERIFY MATCH OF NEW FINISH MATERIALS TO
EXISTING IN COLOR TEXTURE, THICKNESS, CUT, ETC. TO
THE STANDARD OF PRIOR TO INSTALLATIONS.
13. CONTRACTOR IS RESPONSIBLE FOR DEMOLISHING AND
REMOVING ALL MATERIALS FROM PREMISES IN ORDER
TO ACCOMPLISH THE SCOPE OF THE NEW WORK.KEEP
PREMISES CLEAN AT ALLL TIMES ENSURING THAT THERE
ARE NO LOOSE MATERIAS OR ITEMS WHICH MAY CAUSE
INJURY.
14. HAZARDOUS MATERIALS: IT IS NOT EXPECTEDTED
THAT HAZARDOUS MATERIALS WILL BE ENCOUNTEERED
IN THE WORK. IF MATERIALS SUSPECTED OF
CONTAINING HAZARDOUS MATERIALS ARE
ENCOUNTERED, DO NOT DISTURB AND IMMEDIATELY
NOTIFY THE OWNER.
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
AD103
ATTIC DEMOLITION PLAN
RAPJMC
SCALE: 3/8" = 1'-0"F1
ATTIC DEMOLITION PLAN
SCALE: = 1'-0"3/8"
0 2 4 62
OPENING
OPENING
TYP
TYP
B4
A-511
SIM.
REMOVE EXISTING ROOF HATCH.
REMOVE AND DEMOLISH HVAC AND OPENING TO
BE FILLED AND/ OR PATCHED TO MATCH
ADJACENT EXISTING.
DEMOLISH EXISTING CHIMNEY AND FILL AND/ OR
PATCH OPENING TO MATCH ADJACENT
CONSTRUCTION.
REMOVE AND REPLACE EXISTING FAILED AND
DETERIORATED FLASHING .
REPAIR EXISTING SLATE ROOF. REPLACE ALL
BROKEN CRACKED AND MISSING SLATE AND
REPLACE ALL ASSOCIATED FAILED FLASHING
(PINHOLES, OPEN SEAMS, LOOSE AND
MISALIGNED ELEMENTS). APPROXIMATELY 300
SQFT TO BE REPLACED.
REPLACE EXISTING GUTTERS. ALL ASSOCIATED
ALL DOWNSPOUTS AND DRAINS TO BE
CLEANED, SNAKED AND CLEARED FROM ANY
OBSTRUCTION.
REMOVE VINYL SOFFIT. PAINT THE WOODEN
SOFFIT TO MATCH EXISTING IN KIND.
REPAIR AND REFURBISH DAMAGED EAVES AND
ORNAMENTAL BRACKETS TO MATCH IN KIND.
DEMOLISH EXISTING ROOF CONSTRUCTION
WITH MEMBRANE AND ALL ASSOCIATED
FLASHING AND COPINGS, TYP DOWN TO THE
EXISTING ROOF DECK AND PREPARE FOR THE
INSTALLATION OF A NEW ROOFING SYSTEM, I.E.,
TPO.
KEYNOTES:
1. ALL EXISTING ROOF EQUIPMENT TO REMAIN
UNLESS OTHERWISE NOTED; KEYNOTES FOR
FURTHER INFORMATION.
2. ALL WORK SHALL BE PERFORMED IN STRICT
ACORDANCE WITH ALL NATIONAL STATE LOCAL
CODES AND ORDINANCES.
3. CONTRACTOR MUST VERIFY LOCATIONS OF ALL
EXISTING STRUCTURAL, MECHANICAL, PLUMBING
AND ELECTRICAL ELEMENTS PRIOR TO START OF
DEMOLITION.
4. THE GENERAL CONTRACTOR SHALL BE
RESPONSIBLE FOR COORDINATIONG ALL
DEMOLITION WORK.
5. ALL ITEMS SCHEDULED FOR DEMOLIITON SHALL BE
REMOVED FROM THE SITE UNLESS OTHERWISE
NOTED. CONTRACTOR SHLL BE RESPONSIBLE FOR
CLEANING OF SITE ON A DAILY BASIS.
6. ALL ABANDONED MECHANICAL/ ELECTRICAL/
PLUMBING LINES SHALL BE CAPPED OFF BEHIND
FINISHES, UNLESS NOTED OTHERWISE. REFER TO
MCHANICAL/ ELECTRICAL/ PLUMBING DRAIWNGS
FOR ADDITIONAL INFORMATION.
7. ALL OPENINGS WHERE EXISTING CONSTRUCTION
HAS BEEN REMOVED, AND WHICH ARE NOT NOTED
TO REMIN, SHALL BE FILLED AND/ OR PATCHED TO
MATCH THE ADJACENT EXISTING OR NEW FINISH,
INCLUDING ANY FIRE RATINGS REQUIRED.
ROOF DEMOLITION NOTES:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
AD104
ROOF DEMOLITION PLAN
RAPJMC
SCALE: 3/8" = 1'-0"F1
ROOF DEMOLITION PLAN
SCALE: = 1'-0"3/8"
GENERAL
STORAGE
STORAGE
CLOSET
SEE GENERAL DEMOLITION
FLOOR PLAN NOTES
DEMOLITION PLAN LEGEND
AREA OF POSSIBLE HAZARDOUS MATERIAL,
CONTRACTOR RESPONSIBLE FOR
REMEDIATION
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
AD110
BASEMENT PLAN - HAZARDOUS AREA
REPORT
RAPJMC
SCALE: = 1'-0"3/8"
0 2 4 62SCALE: 3/8" = 1'-0"
F1
BASEMENT HAZARDOUS AREA PLAN
GENERAL NOTES:
1. SEE OWNER PROVIDED "COMPREHENSIVE ASBESTOS-CONTAINING MATERIALS
INPECTION" REPORT FROM EFI GLOBAL DATED JANUARY 2010.
2. SEE OWNER PROVIDED "LBP / ASBESTOS RISK ASSESSMENT / ABATEMENT PLAN"
REPORT FROM ALLEY & ASSOCIATES DATED 27 JANUARY 2006.
3. SEE OWNER PROVIDED "LEAD BASED PAINT SURVEY RESULTS" REPORT FROM E.
ROBERTS ALLEY & ASSOCIATES, INC. DATED 27 DECEMBER 2005.
4. SEE OWNER PROVIDED "ASBESTOS OPERATIONS AND MAINTENANCE PROGRAM"
REPORT FROM EFI GLOBAL DATED 27 JANUARY 2010.
REVISIONS DATE
HAZARD MATERIAL REMOVAL NOTES:
1. CONTRACTOR IS ADVISED THAT THE LOCATIONS OF ALL HAZARDOUS MATERIALS
MAY NOT BE CLEARLY KNOWN AND THAT HE SHALL PROCEED WITH CAUTION IN
ALL PHASES OF THE WORK.
2. ADDITIONAL HAZARDOUS MATERIALS MAY BE UNCOVERED DURING THE COURSE
OF THE WORK. SHOULD THE CONTRACTOR SUSPECT, ENCOUNTER OR HAVE
KNOWLEDGE OF ANY HAZARDS NOT LISTED OR DESCRIBED IN THE CONTRACT
DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR INFORMING THE
OWNER.
3. ALL HAZARDOUS MATERIALS SHALL BE REMOVED IN COMPLIANCE WITH
APPLICABLE CODES AND LAWS. REFERENCE VA HAZARDOUS MATERIAL REPORT.
OFFICE
UP
DN
TYP
OFFICE
STORAGE
TOILET
107106
COPY RM
OFFICE
OFFICE
OFFICE
HSK
OFFICE
OFFICE
OFFICE
RECEPTION
OFFICE
OFFICE
STORAGE
EQUIP RM
101A
CORRIDOR
LOBBY
CORRIDOR CORRIDORSEE GENERAL DEMOLITION
FLOOR PLAN NOTES
DEMOLITION PLAN LEGEND
AREA OF POSSIBLE HAZARDOUS MATERIAL,
CONTRACTOR RESPONSIBLE FOR
REMEDIATION
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
AD111
FIRST FLOOR PLAN - HAZARDOUS
AREA REPORT
RAPJMC
SCALE: 3/8" = 1'-0"F1
FIRST FLOOR HAZARDOUS AREA PLAN
SCALE: = 1'-0"3/8"
0 2 4 62
GENERAL NOTES:
1. SEE OWNER PROVIDED "COMPREHENSIVE ASBESTOS-CONTAINING MATERIALS
INPECTION" REPORT FROM EFI GLOBAL DATED JANUARY 2010.
2. SEE OWNER PROVIDED "LBP / ASBESTOS RISK ASSESSMENT / ABATEMENT PLAN"
REPORT FROM ALLEY & ASSOCIATES DATED 27 JANUARY 2006.
3. SEE OWNER PROVIDED "LEAD BASED PAINT SURVEY RESULTS" REPORT FROM E.
ROBERTS ALLEY & ASSOCIATES, INC. DATED 27 DECEMBER 2005.
4. SEE OWNER PROVIDED "ASBESTOS OPERATIONS AND MAINTENANCE PROGRAM"
REPORT FROM EFI GLOBAL DATED 27 JANUARY 2010.
REVISIONS DATE
HAZARD MATERIAL REMOVAL NOTES:
1. CONTRACTOR IS ADVISED THAT THE LOCATIONS OF ALL HAZARDOUS MATERIALS
MAY NOT BE CLEARLY KNOWN AND THAT HE SHALL PROCEED WITH CAUTION IN
ALL PHASES OF THE WORK.
2. ADDITIONAL HAZARDOUS MATERIALS MAY BE UNCOVERED DURING THE COURSE
OF THE WORK. SHOULD THE CONTRACTOR SUSPECT, ENCOUNTER OR HAVE
KNOWLEDGE OF ANY HAZARDS NOT LISTED OR DESCRIBED IN THE CONTRACT
DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR INFORMING THE
OWNER.
OFFICE
CLOSET
204A
CONFERENCE RM
KITCHEN
203A
OFFICE
CLOSET
CORRIDOR
LOBBY
CORRIDOR
STORAGE
TOILET
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MECH RM
HSK
SEE GENERAL DEMOLITION
FLOOR PLAN NOTES
DEMOLITION PLAN LEGEND
AREA OF POSSIBLE HAZARDOUS MATERIAL,
CONTRACTOR RESPONSIBLE FOR
REMEDIATION
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
AD112
SECOND FLOOR PLAN - HAZARDOUS
AREA REPORT
RAPJMC
SCALE: 3/8" = 1'-0"F1
SECOND FLOOR HAZARDOUS AREA PLAN
SCALE: = 1'-0"3/8"
0 2 4 62
GENERAL NOTES:
1. SEE OWNER PROVIDED "COMPREHENSIVE ASBESTOS-CONTAINING MATERIALS
INPECTION" REPORT FROM EFI GLOBAL DATED JANUARY 2010.
2. SEE OWNER PROVIDED "LBP / ASBESTOS RISK ASSESSMENT / ABATEMENT PLAN"
REPORT FROM ALLEY & ASSOCIATES DATED 27 JANUARY 2006.
3. SEE OWNER PROVIDED "LEAD BASED PAINT SURVEY RESULTS" REPORT FROM E.
ROBERTS ALLEY & ASSOCIATES, INC. DATED 27 DECEMBER 2005.
4. SEE OWNER PROVIDED "ASBESTOS OPERATIONS AND MAINTENANCE PROGRAM"
REPORT FROM EFI GLOBAL DATED 27 JANUARY 2010.
REVISIONS DATE
HAZARD MATERIAL REMOVAL NOTES:
1. CONTRACTOR IS ADVISED THAT THE LOCATIONS OF ALL HAZARDOUS MATERIALS
MAY NOT BE CLEARLY KNOWN AND THAT HE SHALL PROCEED WITH CAUTION IN
ALL PHASES OF THE WORK.
2. ADDITIONAL HAZARDOUS MATERIALS MAY BE UNCOVERED DURING THE COURSE
OF THE WORK. SHOULD THE CONTRACTOR SUSPECT, ENCOUNTER OR HAVE
KNOWLEDGE OF ANY HAZARDS NOT LISTED OR DESCRIBED IN THE CONTRACT
DOCUMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR INFORMING THE
OWNER.
GENERAL
STORAGE
STORAGE
CLOSET
NO ARCHITECTURE RCP
DEMOLITION IN THIS
AREA. REFER TO MECH
AND ELECTRICAL DEMO
PLANS
PLAN LEGEND
AREA OF NO ARCHITECTURAL WORK
1. DEMOLITION WORK SHALL BE EXCUTED IN CONFORMANCE WITH ALL CODES
AND ORDINANCES.
2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ELEVATIONS SHOWN
FOR OR TO EXISTING CONSTRUCTION PRIOR TO FABRICATION OR NEW
CONSTRUCTION. NOTIFY ARCHITECT OF ANY DISCREPANCY IMMEDIATELY.
3. CONTRACTOR SHALL ACCOMPLISH ALL DEMOLITION AND REMOVAL WORK AS
REQUIRED TO ACCOMMODATE NEW CONSTRUCTION OR AS SHOWN ON THE
DRAWINGS.
4. COORDINATE DEMOLITION WITH NEW CONSTRUCTION. ALL DEMOLITION AND
REPAIR NECESSARY TO COMPLETE NEW AND REMODEL CONSTRUCTION SHALL
BE PROVIDED. CONTRACTOR SHALL REMOVE EXISTING CONSTRUCTION
WHETHER OR NOT SPECIFICALLY INDICATED ON THE DRAWINGS TO FILITATE
THE COMPLETION OF ALL REQUIRED WORK. CONTRACTOR SHALL VISIT THE
SITE AND VERIFY ALL QUANTITIES AND ITEMS REQUIRED TO BE REMOVED.
5. WHERE EXISTING CEILINGS ARE REMOVED, ALL DISTURBED SURFACES TO
REMAIN EXPOSED ARE TO BE PATCHED TO MATCH ADJOINING SURFACES.
DISTURBED SURFACES TO BE COVERED WITH NEW FINISHES SHALL BE
PATCHED AND PREPARED AS NECESSARY TO RECEIVE NEW FINISHES.
6. WHERE EXISTING MATERIALS OR SYSTEMS ARE TO BE REUSED IN NEW
CONSTRUCTION OR ARE TO REMAIN IN PLACE, PROTECT SUCH MATERIALS AND
SYSTEMS SO THAT THEY MAY BE CONTINUED IN OR RETURNED TO NORMAL
SERVICE. RESTORE ANY EXISTING WORK DAMAGED BY THE OPERATIONS OF
THE CONTRACTOR TO THE LEVEL OF SERVICEABILITY WHICH EXISTED BEFORE
THE DAMAGE OCCURRED.
7. CONTRACTOR SHALL REPLACE AND/OR PROVIDE NEW FIRESTOPPING AT ALL
PENETRATIONS THROUGH EXISTING RATED WALL AND FLOOR/CEILING
CONSTRUCTION TO MAINTAIN INTEGRITY OF THE RATING. FIELD VERIFY EXTENT
OF FIRESTOPPING REQUIRED.
8. CEILING HEIGHT NOTATIONS ON PLAN SPECIFY THE DISTANCE BETWEEN THE
TOP OF THE FINISH FLOOR MATERIAL TO THE BOTTOM OF THE FINISHED
CEILING MATERIAL
9. ALL STRUCTURAL SYSTEMS SHALL BE MAINTAINED. THE CONTRACTOR SHALL
BRACE ALL EXISTING STRUCTURES AND ALL STRUCTRURAL ELEMENTS
NECESSARY DURING DEMOLITION.
10. WHERE DEMOLITION WORK OR RELOCATION OF EXISTING ITEMS LEAVES
UNFINISHED SURFACES AND/OR SUBSTRATES, CUT AND PATCH AS REQUIRED
TO RESTORE SUBSTRATE AND/OR FINISH MATERIAL EVEN AND FLUSH WITH
ADJOINING SURFACES. TEXTURE AND REFINISH TO MATCH EXISTING.
11. CONTRACTOR IS RESPONSIBLE FOR DEMOLISHING AND REMOVING ALL
MATERIALS FROM PREMISES IN ORDER TO ACCOMPLISH THE SCOPE OF THE
NEW WORK.KEEP PREMISES CLEAN AT ALLL TIMES.
DEMOLITION NOTES:
REFLECTED CEILING PLAN DEMO LEGEND
ACT-1. 2'-0" X 2'-0" / 2'-0" X 4'-0" CEILING PANEL
GWBC-1. GYPSUM-CEILING
EXIT SIGNAGE
PENDANT LIGHT
SCONCE LIGHT
6" DOWN LIGHT
2'X2' AIR SUPPLY
2'X2' AIR RETURN
2'X4' LIGHT
2'X2' LIGHT
6" SQUARE DOWN LIGHT
4'-0" STRIP LIGHT
LINEAR DIFFUSER
LINEAR PENDANT LIGHTING
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
AD130
BASEMENT DEMOLITION REFLECTED
CEILING PLAN
RAPJMC
SCALE: 3/8" = 1'-0"
E1
BASEMENT DEMOLITION RCP
SCALE: = 1'-0"3/8"
0 2 4 62
CONTRACTOR NOT TO DEMO FIBER
OPTIC AND FIRE SAFETY CONDUIT
SCALE: N.T.S.
F1
EXISTING FIBER OPTIC AND FIRE SAFETY CONDUIT
SCALE: N.T.S.
F3
EXISTING FIRE OPTIC CONDUIT EXTERIOR
SCALE: N.T.S.
F6
EXISTING PIPE STEAM PIPE
EXISTING FIBER OPTIC CONDUIT
EXISTING STEAM LINE CAPPED AT
WALL. SEE SHEET AD110 FOR
ASBESTOS NOTES
OFFICE STORAGE
TOILET
110107
COPY RM
OFFICE
OFFICE
OFFICE
HSK
OFFICE
OFFICE
OFFICE
RECEPTION
OFFICE
OFFICE
STORAGE
EQUIP RM
101A
CORRIDOR
LOBBY
CORRIDOR
CORRIDOR
1. DEMOLITION WORK SHALL BE EXCUTED IN CONFORMANCE WITH ALL CODES
AND ORDINANCES.
2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ELEVATIONS SHOWN
FOR OR TO EXISTING CONSTRUCTION PRIOR TO FABRICATION OR NEW
CONSTRUCTION. NOTIFY ARCHITECT OF ANY DISCREPANCY IMMEDIATELY.
3. CONTRACTOR SHALL ACCOMPLISH ALL DEMOLITION AND REMOVAL WORK AS
REQUIRED TO ACCOMMODATE NEW CONSTRUCTION OR AS SHOWN ON THE
DRAWINGS.
4. COORDINATE DEMOLITION WITH NEW CONSTRUCTION. ALL DEMOLITION AND
REPAIR NECESSARY TO COMPLETE NEW AND REMODEL CONSTRUCTION SHALL
BE PROVIDED. CONTRACTOR SHALL REMOVE EXISTING CONSTRUCTION
WHETHER OR NOT SPECIFICALLY INDICATED ON THE DRAWINGS TO FILITATE
THE COMPLETION OF ALL REQUIRED WORK. CONTRACTOR SHALL VISIT THE
SITE AND VERIFY ALL QUANTITIES AND ITEMS REQUIRED TO BE REMOVED.
5. WHERE EXISTING CEILINGS ARE REMOVED, ALL DISTURBED SURFACES TO
REMAIN EXPOSED ARE TO BE PATCHED TO MATCH ADJOINING SURFACES.
DISTURBED SURFACES TO BE COVERED WITH NEW FINISHES SHALL BE
PATCHED AND PREPARED AS NECESSARY TO RECEIVE NEW FINISHES.
6. WHERE EXISTING MATERIALS OR SYSTEMS ARE TO BE REUSED IN NEW
CONSTRUCTION OR ARE TO REMAIN IN PLACE, PROTECT SUCH MATERIALS AND
SYSTEMS SO THAT THEY MAY BE CONTINUED IN OR RETURNED TO NORMAL
SERVICE. RESTORE ANY EXISTING WORK DAMAGED BY THE OPERATIONS OF
THE CONTRACTOR TO THE LEVEL OF SERVICEABILITY WHICH EXISTED BEFORE
THE DAMAGE OCCURRED.
7. CONTRACTOR SHALL REPLACE AND/OR PROVIDE NEW FIRESTOPPING AT ALL
PENETRATIONS THROUGH EXISTING RATED WALL AND FLOOR/CEILING
CONSTRUCTION TO MAINTAIN INTEGRITY OF THE RATING. FIELD VERIFY EXTENT
OF FIRESTOPPING REQUIRED.
8. CEILING HEIGHT NOTATIONS ON PLAN SPECIFY THE DISTANCE BETWEEN THE
TOP OF THE FINISH FLOOR MATERIAL TO THE BOTTOM OF THE FINISHED
CEILING MATERIAL
9. ALL STRUCTURAL SYSTEMS SHALL BE MAINTAINED. THE CONTRACTOR SHALL
BRACE ALL EXISTING STRUCTURES AND ALL STRUCTRURAL ELEMENTS
NECESSARY DURING DEMOLITION.
10. WHERE DEMOLITION WORK OR RELOCATION OF EXISTING ITEMS LEAVES
UNFINISHED SURFACES AND/OR SUBSTRATES, CUT AND PATCH AS REQUIRED
TO RESTORE SUBSTRATE AND/OR FINISH MATERIAL EVEN AND FLUSH WITH
ADJOINING SURFACES. TEXTURE AND REFINISH TO MATCH EXISTING.
11. CONTRACTOR IS RESPONSIBLE FOR DEMOLISHING AND REMOVING ALL
MATERIALS FROM PREMISES IN ORDER TO ACCOMPLISH THE SCOPE OF THE
NEW WORK.KEEP PREMISES CLEAN AT ALLL TIMES.
DEMOLITION NOTES:
REFLECTED CEILING PLAN DEMO LEGEND
ACT-1. 2'-0" X 2'-0" / 2'-0" X 4'-0" CEILING PANEL
GWBC-1. GYPSUM-CEILING
EXIT SIGNAGE
PENDANT LIGHT
SCONCE LIGHT
6" DOWN LIGHT
2'X2' AIR SUPPLY
2'X2' AIR RETURN
2'X4' LIGHT
2'X2' LIGHT
6" SQUARE DOWN LIGHT
4'-0" STRIP LIGHT
LINEAR DIFFUSER
LINEAR PENDANT LIGHTING
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Designed
Drawing Title
Approved: Chief Engineering
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740
Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
VAMC MOUNTAIN HOME, TN
CORRECT ADMIN BLDG 20
ENVIRONMENT AND
CONDITION DEFICIENCIES
MARCH 15, 2021
BID DOCUMENTS 621-15-101
AD131
FIRST FLOOR DEMOLITION REFLECTED
CEILING PLAN
RAPJMC
SCALE: 3/8" = 1'-0"E1
FIRST FLOOR DEMOLITION RCP
SCALE: = 1'-0"3/8"
0 2 4 62
NOTE: CONTRACTOR TO VERIFY QUANTITY
OF EXISTING CEILING LIGHTS AND HVAC
DIFFUSERS ON SITE FOR PURPOSE OF
PROPER DEMOLITION BIDDING.
SCALE: N.T.S.
F1
TYPICAL EXISTING LIGHTING AND DIFFUSERS 1ST FLOOR
CLOSET
204A
CONFERENCE RM
KITCHEN
203A
OFFICE
CLOSET
CORRIDOR
LOBBY
CORRIDOR
STORAGE
TOILET
207 OFFICE
OFFICE
208 OFFICE
OFFICE
OFFICE
OFFICE
MECH RM
HSK
1. DEMOLITION WORK SHALL BE EXCUTED IN CONFORMANCE WITH ALL CODES
AND ORDINANCES.
2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ELEVATIONS SHOWN
FOR OR TO EXISTING…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .