36C24920R0008-007.pdf

PDF Posted

Attached to
Project 614-17-112 - Renovate Bldg. -1 Clinical Lab
Solicitation number
36C24920R0008
Issued by

About this file

This document includes a federal contract solicitation notice and construction drawings for a hospital renovation project. The Memphis VA Medical Center is seeking a contractor experienced in healthcare construction to renovate Building 1's clinical lab for Project 614-17-112. The estimated value of the construction work is between $5-10 million. Services required include general construction, plumbing, mechanical, electrical, and exterior work in accordance with provided specifications and drawings. As this project will take place within an active hospital, infection control and other medical environment protocols must be followed. The solicitation is anticipated to be released by November 6, 2019 following a Lowest Price Technically Acceptable source selection process. This is a 100% SDVOSB set-aside awarded under 38 U.S.C. 8127(d). The awarded contractor must be verified in the CVE database and have an active SAM registration. Questions regarding this opportunity must be submitted in writing with the relevant project details included.

36C24920R0008 17.1055 - 2019.05.01.02_General Sheets.pdf

View the file

Other files

File Type Posted
36C24920R0008-0009005.docx DOCX document
36C24920R0008-0008000.docx DOCX document
36C24920R0008-0008003.pdf PDF
36C24920R0008-0008001.pdf PDF
36C24920R0008-0008002.pdf PDF
36C24920R0008-0007000.docx DOCX document
36C24920R0008-0006004.pdf PDF
36C24920R0008-0006007.pdf PDF
36C24920R0008-0006005.pdf PDF
36C24920R0008-0006011.pdf PDF
36C24920R0008-0006006.pdf PDF
36C24920R0008-0006001.pdf PDF
36C24920R0008-0006000.docx DOCX document
36C24920R0008-0006010.pdf PDF
36C24920R0008-0006012.pdf PDF
36C24920R0008-0006008.pdf PDF
36C24920R0008-0006002.pdf PDF
36C24920R0008-0006009.pdf PDF
36C24920R0008-0006003.pdf PDF
36C24920R0008-0005000.docx DOCX document
36C24920R0008-0004000.docx DOCX document
36C24920R0008-0004001.pdf PDF
36C24920R0008-0004002.pdf PDF
36C24920R0008-0003000.docx DOCX document
36C24920R0008-0003001.pdf PDF
36C24920R0008-0002006.pdf PDF
36C24920R0008-0002005.pdf PDF
36C24920R0008-0002008.pdf PDF
36C24920R0008-0002001.txt TXT text file
36C24920R0008-0002004.pdf PDF
36C24920R0008-0002003.pdf PDF
36C24920R0008-0002000.docx DOCX document
36C24920R0008-0002007.pdf PDF
36C24920R0008-0002002.pdf PDF
36C24920R0008-0001000.docx DOCX document
36C24920R0008-011.pdf PDF
36C24920R0008-003.pdf PDF
36C24920R0008-004.pdf PDF
36C24920R0008-010.xlsx XLSX spreadsheet
36C24920R0008-009.xlsx XLSX spreadsheet
36C24920R0008-005.pdf PDF
36C24920R0008-006.pdf PDF
36C24920R0008-012.pdf PDF
36C24920R0008-001.docx DOCX document
36C24920R0008-008.pdf PDF
36C24920R0008-002.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

N O T F

O R

C

N S

TR

U C

TIO

N o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

Building Number

C U s e rs \l s p lic h a l\ D o c u m e n ts \1

.1

V

A M e m p h is

B ld g

P ri m a ry

C a re ls p lic h a l.

rv t

/1 /2

:0

:3

P M

GI000

COVER SHEET

GUIDON DESIGN, INC

1221 N PENNSYLVANIA STEET, SUITE 200

INDIANAPOLIS, IN 46202

317.800.6388

ANDREW SCHAEWE

CMTA CONSULTING ENGINEERS, INC

10411 MEETING STREET

PROSPECT, KY 40059

502.326.3085

ANDREW MYERS

RENOVATE BUILDING 1 PRIMARY

CARE

MEMPHIS VAMC

614-17-113

RYAN STEPHENS,

COR MEMPHIS, TN

05/01/2019 AWS JP

BID SET

FULLY SPRINKLERED

Contact:Contact: Contact:

CMTA CONCULTING ENGINEERS, INC.

Andrew Myers

Project Engineer

MECHANICAL,

ELECTRICAL &

PLUMBING

MEMPHIS VAMC

Sonya Ellis

COR

1030 Jefferson Avenue Memphis, TN 38104 p: 901.523.8990 x 5026 e: sonya.ellis@va.gov

OWNER

GUIDON DESIGN INC.

Andrew Schaewe

Project Manager

1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202 p: 317.800.6388 x 141 e: aschaewe@guidondesign.com

ARCHITECT

10411 Meeting Street Prospect, KY 40059 p: 502.326.3085 e: amyers@cmtaegrs.com

CAMPUS MAP

VICINITY MAP

BUILDING SITE

N

N

N

SHEET LIST

SHEET NUMBER SHEET NAME

GENERAL

GI000 COVER SHEET

GI101 LIFE SAFETY PLAN

GI102 INFECTION CONTROL/PHASING PLAN

GI103 BID ALTERNATES

HA101 HAZARDOUS MATERIAL REMOVAL PLAN

ARCHITECTURAL

AS001 ARCHITECTURAL ABBREVIATIONS AND GENERAL NOTES

AS002 ARCHITECTURAL SYMBOLS AND WALL TYPES

AD101 FIRST FLOOR DEMOLITION PLAN

AD401 ENLARGED DEMOLITION PLAN

AS101 FIRST FLOOR ARCHITECTURAL PLAN

AS102 FIRST FLOOR DIMENSION PLAN

AS111 FIRST FLOOR REFLECTED CEILING PLAN

AS401 ENLARGED PLANS

AS402 ENLARGED PLANS

AS403 ENLARGED REFLECTED CEILING PLAN & DETAILS

AS501 DETAILS

AS601 DOOR SCHEDULE

AS801 INTERIOR ELEVATIONS

AS802 INTERIOR ELEVATIONS

AS803 INTERIOR ELEVATIONS

AS804 INTERIOR ELEVATIONS

AS811 INTERIOR SECTIONS AND DETAILS

AS901 SIGNAGE PLAN

AS902 SIGNAGE TYPE

AS911 3D ISOMETRICS

AF101 FIRST FLOOR WALL FINISH PLAN

AF102 FIRST FLOOR FLOOR FINISH PLAN

AF601 FINISHES AND EQUIPMENT SCHEDULE

AQ101 EQUIPMENT FLOOR PLAN

AQ102 ENLARGED EQUIPMENT PLANS

MECHANICAL

ML100 MECHANICAL LEGEND AND GENERAL NOTES

MD100 PARTIAL GROUND FLOOR PLAN - MECHANICAL DEMOLITION

MD101 PARTIAL FIRST FLOOR PLAN - AIR DISTRIBUTION DEMOLITION

MD102 PARTIAL FIRST FLOOR PLAN - HYDRONICS DEMOLITION

MD103 PARTIAL SECOND FLOOR PLAN - MECHANICAL DEMOLITION

MD104 MECHANICAL ROOF PLAN - DEMOLITION

MD105 MECHANICAL FOURTH FLOOR ROOF PLAN - DEMOLITION

MH100 PARTIAL BASEMENT FLOOR PLAN - MECHANICAL

MH101 PARTIAL FIRST FLOOR PLAN - AIR DISTRIBUTION

MH102 PARTIAL SECOND FLOOR PLAN - MECHANICAL

MH103 MECHANICAL ROOF PLAN

MP100 PARTIAL GROUND FLOOR PLAN - HYDRONICS

MP101 PARTIAL FIRST FLOOR PLAN - HYDRONICS

MH200 MECHANICAL DETAILS

MH201 MECHANICAL DETAILS

MH202 MECHANICAL DETAILS

MH203 MECHANICAL CONTROLS SCHEMATICS

MH204 MECHANICAL CONTROLS SCHEMATICS

MS100 MECHANICAL SCHEDULES

ELECTRICAL

ES101 ELECTRICAL LEGEND

ED101 PARTIAL FIRST FLOOR PLAN - ELECTRICAL DEMOLITION

ED102 ROOF PLAN - ELECTRICAL DEMOLITION

ES201 PARTIAL FIRST FLOOR PLAN - LIGHTING

ES301 PARTIAL FIRST FLOOR PLAN - POWER

ES302 PARTIAL ROOF PLAN - POWER

ES401 PARTIAL FIRST FLOOR PLAN - SYSTEMS

ES500 PARTIAL GROUND FLOOR PLAN - ELECTRICAL INTERCONNECTIONS

ES501 PARTIAL FIRST FLOOR PLAN - ELECTRICAL INTERCONNECTIONS

ES502 PARTIAL SECOND FLOOR PLAN - ELECTRICAL INTERCONNECTIONS

ES601 POWER DISTRIBUTION RISER DIAGRAM AND DETAILS

ES701 LIGHT FIXTURE SCHEDULE AND DETAILS

ES702 PANELBOARD SCHEDULES

ES801 TELECOMMUNICATION DETAILS

ES802 ELECTRICAL DETAILS

PLUMBING

PL101 PLUMBING LEGEND, SCHEDULES & DETAILS

PD101 GROUND FLOOR - PLUMBING DEMOLITION PLAN

PD102 FIRST FLOOR - PLUMBING DEMOLITION PLAN

PP101 GROUND FLOOR - PLUMBING PLAN

PP102 FIRST FLOOR - PLUMBING PLAN

PP103 SANITARY WASTE AND VENT RISER DIAGRAM NO.1

PP104 SANITARY WASTE AND VENT RISER DIAGRAM NO.2

PP105 SANITARY WASTE AND VENT RISER DIAGRAM NO.3

FIRE PROTECTION

FX101 FIRE PROTECTION NOTES & DETAILS

FX102 FIRST FLOOR - FIRE PROTECTION PLAN

MEMPHIS VA MEDICAL CENTER

MEMPHIS, TENNESSEE

RENOVATE BUILDING 1 PRIMARY CARE

VA PROJECT #614-17-113

BID SET

PROJECT LOCATION

PROJECT LOCATION

PROJECT LOCATION

Revisions: Date:

CODE ANALYSIS LEGEND

TOTAL OCCUPANCY

FEC

EXIT

OCCUPANCY LOAD FACTOR

EXITS REQUIRED

SQUARE FOOTAGE

OCCUPANCY TYPE

EGRESS EXIT SIGNAGE

FIRE EXTINGUISHER CABINET

DIAGONAL DISTANCE

EXIT SEPARATION DISTANCE

EGRESS PATH

2 HR - FIRE SEPARATION

1 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

B

1500 SF

REFER TO VA MANUAL PG-18-3 FOR ADDITIONAL CODES, STANDARDS, GUIDELINES AND

REGULATIONS, BELOW LISTING IS NOT COMPREHENSIVE.

ICC, INTERNATIONAL BUILDING CODES, 2018 EDITION (IBC)

ASCE-07-10

ACI 318-11

ACI 530-11

AISC 341-10

AISC 360-10

PCI MNL 120-10, DESIGN HANDBOOK

NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2013 EDITION

NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2016 EDITION

NFPA 14, STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEM, 2016

EDITION

NFPA 20, STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE

PROTECTION, 2016 EDITION

NFPA 24, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND

THEIR APPURTENANCE, 2016 EDITION.

NFPA 54 NATOINAL FUEL GAS CODE, 2015 EDITION

NFPA 70, NATIONAL ELECTRIC CODE, 2014 EDITION

NFPA 72, NATIONAL FIRE ALARM CODE, 2016 EDITION

NFPA 75, STANDARD FOR THE PROTECTION OF ELECTRICAL COMPUTER/DATA

PROCESSING EQUIPMENT, 2017 EDITION

NFPA 77, RECOMMENDED PRACTICE ON STATIC ELECTRICITY, 2014 EDITION

NFPA 80, STANDARD FOR FIRE DOORS AND FIRE WINDOWS, 2016 EDITION

NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING

SYSTEMS, 2015 EDITION.

NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS, 2015 EDITION

NFPA 99, STANDARD FOR HEALTHCARE FACILITIES, 2015 EDITION

NFPA,99B, STANDARD FOR HYPOBARIC FACILITIES, 2015 EDITION

NFPA 101, LIFE SAFETY CODE, 2015 EDITION

NFPA 110, STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS

NFPA 220, STANDARD TYPES OF BUILDING CONSTRUCTION, 2015 EDITION.

NFPA 780, STANDARD FOR INSTALLATION OF LIGHTING PROTECTION SYSTEMS, 2017

EDITION

NFPA 54 TYPE 2 CLOTHES DRYER UL 705 DEDPY, 2015 EDITION

MOST RECENT EDITION OF NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA

5000 AND NFPA 900

ASHRAE 90.1-2016 HVAC SYSTEMS

ANSI A117.1-2009 STANDARD ON ACCESSIBLE & USABLE BUILDINGS AND FACILITIES

2010 ADA STANDARDS FOR ACCESSIBLE DESIGN

OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS

ENERGY POLICY ACT OF 2005 (EPACT)

EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY, AND

TRANSPORTATION MANAGEMENT.

VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD

STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL

INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).

VA BARRIER FREE DESIGN GUIDE PG-18-13, ABAAS

ARCHITECTURAL, AUGUST 1, 2014

ASBESTOS ABATEMENT, JULY 2011

CMP SCHEDULE AND RISK MANAGEMENT, VOL. 1 & 2, DECEMBER 2012

ELECTRICAL, DECEMBER 2015

ENERGY SUSTAINABILITY, MAY 2014

EQUIPMENT, JANUARY 2006

ESTIMATING, MARCH 8, 2011

NFPA INTERIM GUIDANCE FOR PROJECTS, PG-18-17, SEPTEMBER 30, 2010

FIRE PROTECTION, SEVENTH EDITION REVISED DECEMBER 2015

HVAC FOR NEW, REPLACEMENT, ADD. AND REN. OF EXIST. CA FACILITIES, MARCH 2011

INTERIOR DESIGN, MAY 2008

PHYSICAL SECURITY DESIGN MANUAL, JANUARY 2015

PLUMBING, NOVEMBER 2014

STRUCTURAL, FEBRUARY 1, 2014

WAY FINDING AND SIGNAGE, INTERIOR, DECEMBER 2012

SEISMIC DESIGN REQUIREMENTS, H-18-8, AUGUST 2013

ENVIRONMENTAL PLANNING GUIDANCE PG-18-17 NEPA INTERIM GUIDELINES FOR

PROJECTS SEPTEMBER 30, 2010

ELEVATOR DESIGN MANUAL, AUGUST 2016

EPA GUIDELINES CHECKLIST

VA DESIGN MANUALS PG-18-10:

GOVERNING CODES:

CODE CRITERIA

GENERAL: THIS SUMMARY OF CODE REQUIREMENTS IS BASED PRIMARILY ON NFPA 101 (LSC). DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE IDENTIFIED. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).

LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES.

NOTES:

CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.

CODE REVIEW

THE 2018 EDITION OF THE LIFE SAFETY CODE, NFPA 101, HAS BEEN USED TO REVIEW THIS PROJECT FOR COMPLIANCE WITH THE FIRE AND LIFE SAFETY REQUIREMENTS. FOR FEATURES NOT ADDRESSED BY NFPA 101 AND THE REFERENCED NATIONAL FIRE CODES, THE 2018 EDITION OF THE INTERNATIONAL

BUILDING CODE HAS BEEN USED.

PROJECT SCOPE

THE PROJECT SCOPE INCLUDES THE RENOVATION OF BUILDING 1, FIRST FLOOR PRIMARY CARE CLINIC. THE NEW INTERIOR BUILD OUT IS FOR A PRIMARY CARE CLINIC WITH WALL CONSTRUCTION, FINISHES, MECHANICAL, LIGHTING AND PLUMBING SYSTEMS. RENOVATION WORK INCLUDES INTERIOR RENOVATION AND REMOVAL OF EXISTING CLINICAL LAB, INTERIOR WALLS, PATCHING AND MATCHING FINISHES AND REMODEL OF EXISTING AREAS TO CREATE TOILET ROOMS AND CORRIDORS. THE OVERALL FACILITY IS EXISTING AND THE SMOKE ZONES SHALL REMAIN WITH MINIMAL MODIFICATION TO EXISTING SMOKE BARRIER LOCATION TO ACCOMMODATE NEW BOUNDARIES CREATED TO ACCOMMODATE THE NEW LAB SPACE. THE OVERALL BUILDING IS A HOSPITAL, CHAPTER 19 OF THE NFPA 101 LSC, THE AREA BEING RENOVATED IS A BUSINESS OCCUPANCY AND SHALL COMPLY WITH BOTH CHAPTER 19 AND 18 TO MAINTAIN THE INTEGRITY OF THE OVERALL BUILDING AND THE INTERIOR ELEMENTS SHALL COMPLY WITH CHAPTER 38 TO ACCOMMODATE THE OCCUPANCY TYPE OF THAT AREA.

CODE ANALYSIS

THE CONSTRUCTION TYPE IS DETERMINED BASED UPON THE ALLOWABLE AREA AND HEIGHT REQUIREMENTS OF CHAPTER 5 OF THE 2018 IBC. CONSTRUCTION TYPE AND MATERIALS SHALL BE PER CHAPTER 6 OF THE IBC FOR TYPE I-B, ASSUMED, CONSTRUCTION AS FOLLOWS: IS EXISTING AND NOT TO BE CHANGED.

1. OCCUPANCY TYPE: B-BUSINESS, IBC CHAPTER 3/LSC CHAPTER 38

2. CONSTRUCTION TYPE: I-B (IBC CHAPTER 5)

3. FIRE RESISTIVE RATINGS TYPE CONSTRUCTION, CHAPTER 6 IBC/NFPA 101:

STRUCTURAL FRAME: NONCOMBUSTIBLE, 2-HOUR FIRE RESISTIVE

BEARING WALLS

EXTERIOR: NONCOMBUSTIBLE, 2 -HOUR FIRE RESISTIVE

INTERIOR: NONCOMBUSTIBLE, 2-HOUR FIRE RESISTIVE

NON-BEARING WALLS AND PARTITIONS

EXTERIOR: NONCOMBUSTIBLE, VARIES PER TABLE 602-HOUR FIRE RESISTIVE

INTERIOR: NONCOMBUSTIBLE, 0-HOUR FIRE-RESISTIVE

FLOOR: NONCOMBUSTIBLE, 2-HOUR FIRE RESISTIVE

ROOF: NONCOMBUSTIBLE, 1-HOUR FIRE RESISTIVE

SHAFT ENCLOSURES 2-HOUR FIRE RESISTIVE >4 STORIES (IBC 713.4, LSC 12.3.6)

4. STRUCTURAL DESIGN SHALL COMPLY WITH CHAPTER 16 OF THE IBC.

5. ALLOWABLE HEIGHT: IS EXISTING AND NOT TO BE CHANGED. (IBC, TABLE 504.3)

6. ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLAN: IS EXISTING AND NOT TO BE CHANGED. (IBC, TABLE 504.4)

7. ALLOWABLE AREA: IS EXISTING AND NOT TO BE CHANGED. (IBC, TABLE 506.2)

8. BUILDING SEPARATION: IS EXISTING AND NOT TO BE CHANGED. (IBC, TABLE 602)

9. MEANS OF EGRESS

• CLEAR WIDTH OF CORRIDORS SHALL BE CLEAR 44 INCHES.

• CLEAR WIDTH OF DOORS SHALL BE CLEAR 32 INCHES

• NOT LESS THAN 2 EXITS SHALL BE PROVIDED PER FLOOR.

• ADDITION OCCUPANCY LOAD: <500 THEREFORE 2 EXITS REQUIRED (LSC 7.4.1)

• MAXIMUM TRAVEL DISTANCE, FULLY SPRINKLED: 300 FEET (LSC 38.2.6.3)

• COMMON PATH OF TRAVEL SHALL NOT EXCEED 100 FEET (LSC 38.2.5.3.1)

• DEAD END CORRIDORS SHALL NOT EXCEED 50 FEET. (LSC 38.2.5.2.1)

• MEANS OF EGRESS SHALL BE ILLUMINATED. (LSC 38.2.8)

• EMERGENCY LIGHTING SHALL BE PROVIDED, BUILDING OVER 3 STORIES. (LSC 38.2.9.1)

• EXIT SIGNAGE SHALL BE PROVIDED. (LSC 38.2.10)

10. PROTECTION FROM ANY AREA HAVING A DEGREE OF HAZARD GREATER THAN THAT NORMAL TO THE GENERAL OCCUPANCY OF THE BUILDING OR STRUCTURE SHALL BE PROVIDED BY PROTECTING THE AREA WITH AUTOMATIC EXTINGUISHING SYSTEMS IN ACCORDANCE WITH SECTION 9.7(3). WHERE HAZARD IS SEVER PER LSC CHAPTER 38, SOILED HOLDING, PROTECTION IS PROVIDED WITH AN AUTOMATIC EXTINGUISHING SYSTEMS THE SPACE SHALL ALSO BE ENCLOSED WITH

SMOKE PARTITIONS IN ACCORDANCE WITH SECTION 8.4.

• 1-HOUR FIRE RESISTANCE RATING AND AUTOMATIC SPRINKLER SYSTEM IS REQUIRED FOR THE FOLLOWING: SOILED HOLDING AND HIGH HAZARD

CONTENT AREAS PER LSC 38.2.2.

11. INTERIOR FINISH

• WALLS AND CEILINGS: INTERIOR FINISH FLAME SPREAD SHALL BE LIMITED PER CHAPTER 8 OF THE NFPA 101 TO CLASS A, B AND C MATERIALS. INTERIOR

WALL AND CEILING FINISH SHALL BE CLASS A OR CLASS B IN EXITS, CORRIDORS AND LOBBIES; AND CLASS A, CLASS B, OR CLASS C IN ALL OTHER AREAS.

(LSC 38.3.3)

• CLASS A: FLAME SPREAD 0-25; SMOKE DEVELOPED 0-450.

• CLASS B: FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450.

• CLASS C: FLAME SPREAD 76-200; SMOKE DEVELOPED 0-450

• FLOORS: INTERIOR FLOOR FINISH SHALL BE CLASS I OR CLASS II IN CORRIDORS AND EXITS.

• FABRIC DRAPERIES, CURTAINS (EXCLUDING SHOWER CURTAINS, BUT INCLUDING CUBICLE CURTAINS), AND OTHER LOOSELY HANGING FABRICS AND

FILMS SERVING AS FURNISHINGS OR DECORATIONS IN HEALTH CARE OCCUPANCIES MUST MEET THE FLAME RESISTANCE REQUIREMENTS OF NFPA 701, STANDARD METHODS OF FIRE TESTS FOR FLAME-RESISTANT TEXTILES AND FILMS.

• UPHOLSTERED FURNITURE AND MATTRESSES. UPHOLSTERED FURNITURE AND MATTRESSES MUST ALSO MEET SPECIFIED REQUIREMENTS, BASED ON

NFPA 260, NFPA 261, NFPA 266, 16 CRF 1632, ASTME E1537, AND ASTME E1590

12. EXTINGUISHMENTS REQUIREMENTS, PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPA 10. (38.3.5)

13. DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS.

• FIRE ALARM SYSTEM SHALL BE PROVIDED LSC, NFPA 70 (NEC) AND NFPA 72. (LSC 9.6.1)

• FIRE ALARM MAY BE BY MANUAL MEANS (LSC 38.4.2)(LSC 9.6.2)

• OCCUPANT NOTIFICATION SHALL BE THROUGH AUTOMATIC MEANS. (LSC 38.3.4.3)

• SMOKE DETECTION SHALL BE PROVIDED PER NFPA 72.

• EMERGENCY RESPONDER NOTIFICATION SHALL BE NOTIFIED BY ALARM AND DETECTION SYSTEM. (LSC 38.3.4.4)

14. FIRE SUPPRESSION:

SPRINKLER SYSTEM: BUILDING IS REQUIRED TO BE SPRINKLED THROUGHOUT IN ACCORDANCE WITH NFPA 13.

THE SPRINKLER SYSTEM SHALL BE HYDRAULICALLY DESIGNED IN ACCORDANCE WITH 2013 EDITION OF NFPA 13 AND THE SIXTH EDITION OF THE DEPARTMENT OF

VETERANS AFFAIRS FIRE PROTECTION DESIGN MANUAL: MINIMUM DESIGN REQUIREMENTS:

STORAGE MECHANICAL AND ELECTRICAL ROOMS SHALL BE PROTECTED AS:

ORDINARY HAZARD OCCUPANCY, GROUP 1: 0.15 GPM/FT2 OVER 1,500 FT2.

HOSE STREAM ALLOWANCE: 250 GPM

ALL OTHER AREAS SHALL BE PROTECTED AS:

LIGHT HAZARD OCCUPANCY: 0.10 GPM/FT2 OVER 1,500 FT2.

HOSE STREAM ALLOWANCE: 100 GPM

ALL SPRINKLERS WITHIN THE SMOKE ZONE SHALL BE QUICK RESPONSE SPRINKLERS.

15. CONSTRUCTION BARRIERS CONSTRUCTED ALONG MEANS OF EGRESS ALONG HEALTHCARE OCCUPANCIES (LSC CHAPTER 18 AND 19) SHALL BE CONSTRUCTED

AND MAINTAINED PER NFPA 241.

CODE ANALYSIS - NFPA 101

KEY PLAN

N

G

A

B

C

D

E

F

H

1 2 3 4 5 6 7 8 9 10 11

7074 SF

15472

A

PACT TOILET

CW183

STORAGE

CW160G

TELE-HEALTH

CW160B

TELE-RETINAL

CW160A

TEAM WORK AREA

CW160

TELE-HEALTH

CW160D

HYBRID EXAM

CW160E

SOILED

CW161

CLEAN

CW162

HYBRID EXAM

CW186

HYBRID EXAM

CW150S

HYBRID EXAM

CW150R

HYBRID EXAM

CW150Q

WOMEN EXAM

CW150P

WOMEN EXAM

CW150N

WOMEN'S TOILET

CW150OHYBRID EXAM

CW150M

HYBRID EXAM

CW150L

HYBRID EXAM

CW150K

HYBRID EXAM

CW150J

PROCEDURE

CW150H

PROCEDURE TOILET

CW150I

HYBRID EXAM

CW150G

HYBRID EXAM

CW150F

HYBRID EXAM

CW150E

HYBRID EXAM

CW150D

HYBRID EXAM

CW140Q

HYBRID EXAM

CW150C

HYBRID EXAM

CW150B

HYBRID EXAM

CW150A

NURSE MANAGER

CW152

HAC

CW171

PATIENT CORRIDOR

CWC9

PATIENT CORRIDOR

CWC4

WOMEN EXAM

CW140J

WOMEN TOILET

CW140I

WOMEN EXAM

CW140H

HYBRID EXAM

CW140G PACT TOILET

CW140U

HYBRID EXAM

CW140F

HYBRID EXAM

CW140E

HYBRID EXAM

CW140D

HYBRID EXAM

CW140C

HYBRID EXAM

CW140B

HYBRID EXAM

CW140A

HT / WT

CWC6-A

HYBRID EXAM

CW140T

HYBRID EXAM

CW140S

HYBRID EXAM

CW140R

HT / WT

CWC4-A

PACT TOILET

CW151

HYBRID EXAM

CW140P

HYBRID EXAM

CW140O

HYBRID EXAM

CW140N

HYBRID EXAM

CW140M

HYBRID EXAM

CW140L

HYBRID EXAM

CW140K

FAMILY TOILET

CW174

PATIENT CORRIDOR

CWC6

TEAM WORK AREA

CW140

TEAM WORK AREA

CW150

STAFF LOCKER

CW157

STAFF FEMALE

TOILET

CW158

STAFF MALE TOILET

CW159

PACT WORKROOM

CW142

PACT WORKROOM

CW143

CLEAN

CW144

STAFF FEMALE

TOILET

CW145

STAFF MALE TOILET

CW146

EQUIPMENT

CW147

SHAFT

SOILED

CW149

PACT WORKROOM

CW148

SHAFT

STAFF LOUNGE /

CONFERENCE /

TRAINING ROOM

CW155

STAIR NO. 3

STAFF CORRIDOR

CWC5

FAMILY TOILET

CW175

HT / WT

CWC9-A

FEMALE PUBLIC

TOILET

CW170B

MALE PUBLIC

TOILET

CW170A

STAIR NO. 1

MEDICATION

CW150T

MEDICATION

95-A

WHEELCHAIR

CWC1E

CHECK-IN KIOSK

CWC1FVOLUNTEER

CWC1D

RECEPTION

CW180

WAITING AREA

CW170

CORRIDOR

CWC1

19007 SF

100191

B

FEC

FEC

FEC

FEC

FECFEC

FEC

FEC

FEC

FEC

FEC

FEC

FEC

FEC

FEC

BUILDING

EXIT

SUITE EXIT

SUITE EXIT

SUITE

EXIT

SUITE

EXIT

SUITE

EXIT

SUITE EXIT

SUITE EXIT

TRAVEL DISTANCE: 211' - 8"

EXIT

E X

IT S

E

P A

R A

TIO

N

: 119' - 3"

DIAGONAL DISTANCE: 188' - 9"

ELECTRICAL

CW160F

HAC

CW187

MEDICATION

CW160-A

OFFICE MANAGER

CW153

CHIEF MEDICAL

OFFICER

CW154

SHARED MEDICAL

APPT

CW185

SHARED MEDICAL

APPT

CW184

STORAGE

CW184A

STORAGE

CW185A

PACT TOILET

CW186

DATA

CW169

ENTRANCE

VESTIBULE

CWC1A

TOILET VESTIBULE

CWC15A

CORRIDOR

CWC14

CORRIDOR

CWC13

ELECTRICAL

CW160C

TRAVEL DISTANCE: 174' - 3"

N

STAFF LOUNGE /

CONFERENCE /

TRAINING ROOM

CW155

WAITING AREA

CW170

Project Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

N O T F

N

STR

U C

TIO

N o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

Building Number

C U s e rs \l s p lic h a l\ D o c u m e n ts \1

.1

V

A M e m p h is

B ld g

P ri m a ry

C a re ls p lic h a l.

rv t

/1 /2

:1

:2

P M

GI101

LIFE SAFETY PLAN

GUIDON DESIGN, INC

1221 N PENNSYLVANIA STEET, SUITE 200

INDIANAPOLIS, IN 46202

317.800.6388

ANDREW SCHAEWE

CMTA CONSULTING ENGINEERS, INC

10411 MEETING STREET

PROSPECT, KY 40059

502.326.3085

ANDREW MYERS

RENOVATE BUILDING 1 PRIMARY

CARE

MEMPHIS VAMC

614-17-113

RYAN STEPHENS,

COR MEMPHIS, TN

05/01/2019 AWS JP

BID SET

FULLY SPRINKLERED

LIFE SAFETY OCCUPANCY COUNT

AREA SF OCC OCC FACTOR # OF OCC

FIRST FLOOR

WAITING AREA 7074 SF A 15 472

PRIMARY CARE 19007 SF B 100 191

PRIMARY CARE TOTAL: 26081 SF 663

SCALE: 3/32" = 1'-0"GI101

1 FIRST FLOOR - LIFE SAFETY PLAN

OCCUPANCY LOAD: 663 X .2 = 133 INCHES TOTAL

EXISTING DOOR WIDTH: 160 INCHES TOTAL

INFECTION CONTROL PROJECT INFORMATION

CONSTRUCTION ACTIVITY - FIRE RISK: TYPE C

PATIENT RISK GROUP: MEDIUM

CLASS OF PRECAUTION MATRIX: III

REFER TO LIST OF REQUIRED INFECTION CONTROL PRECAUTIONS OUTLINED

BY CLASS IN SPECIFICATION 010110 AND ADDITIONAL INFORMATION.

REFER TO DRAWINGS, SPECIFICATIONS AND DOOR HARDWARE SCHEDULE

FOR ADDITIONAL INFORMATION.

PROJECT SHALL BE COMPLETED IN TWO PHASES WITH PHASE ONE BEING

COMPLETED PRIOR TO PHASE TWO.

COORDINATE FULL SCOPE OF WORK WITH ENGINEERING DRAWINGS AND

FIELD VERIFICATION. CONTRACTOR IS RESPONSIBLE FOR SCOPE OF ABOVE

CEILING WORK REQUIRED ABOVE AND BELOW THE FLOOR PLATE OF THE

PROJECT BOUNDARY.

COORDINATE LOCATION OF TEMPORARY INFECTION CONTROL (IC) BARRIER

WALL CONSTRUCTION AND INFECTION CONTROL (IC) MEASURES WITH COR

AND PATIENT SAFETY/ INFECTION CONTROL REPRESENTATIVE. TEMPORARY

IC BARRIER WALL CONSTRUCTION LOCATIONS IN DRAWINGS ARE

APPROXIMATE. CONTRACTOR SHALL PROVIDE DRAWING TO COR AND

PATIENT SAFETY/ INFECTION CONTROL REPRESENTATIVE ONCE ICRA

PROTOCOLS AND PLAN IS APPROVED.

SCHEDULE AND TIME OF CONSTRUCTION WORK TO BE APPROVED BY COR

AND NURSING STAFF BEFORE CONSTRUCTION MAY BEGIN. PROVIDE PHASING

INFORMATION FOR ABOVE CEILING WORK IN THE CONTRACTOR PROVIDED

CMP SCHEDULE FOR WORK ALSO REQUIRED ABOVE AND BELOW THE FLOOR

PLATE OF THE PROJECT BOUNDARY.

ABOVE CEILING WORK SHALL TAKE PLACE BETWEEN THE HOURS OF 5:00 PM

AND 5:00 AM. IN AREAS THAT REQUIRE ABOVE CEILING WORK WHERE

CEILINGS ARE TO REMAIN, CEILING TILES SHALL BE REMOVED AND STORED IN

A SAFE MANOR UNTIL CEILING TILES CAN BE REINSTALLED. DAMAGED AND

BROKEN CEILING TILES SHALL BE REPLACED BY CONTRACTOR.

EXIT/ACCESS FOR ADJACENT OPERATIONAL AREAS SHALL BE MAINTAINED

DURING NORMAL BUSINESS HOURS. SEE SPECIFICATION FOR HOURS OF

OPERATION.

WORK REQUIRING VIBRATION OR LOAD NOISE SHALL TAKE PLACE BETWEEN

THE HOURS OF 5:00 PM AND 5:00 AM. EVERY EFFORT SHALL BE MADE TO

KEEP NOISE AND VIBRATION TO A MINIMUM.

PROVIDE THE FOLLOWING INFECTION CONTROL MEASURES, A 24"X36" STICKY

WALK OFF MAT AND HAND SANITIZER AT EACH TEMPORARY DOOR LOCATION.

MAT SHALL BE REPLACED OR CLEANED AS NECESSARY

PROVIDE THE VA AND OSHA REQUIRED TEMPORARY SIGNAGE AT EACH

TEMPORARY DOOR LOCATION.

CONTRACTOR SHALL SUPPLY SPILL KIT. SPILL KIT TO INCLUDE SHOP VAC,

MULTI-PURPOSE SPILL CONTROL SORBENTS TO ABSORB NON AGGRESSIVE

LIQUIDS UP TO 30 GALLONS.

ALL NEW MATERIAL MOVED THROUGH THE FACILITY SHALL BE COVERED WITH

4 MIL. POLY SHEET.

ALL DEMOLITION MATERIAL SHALL BE REMOVED FROM THE PROJECT

BOUNDARY THROUGH THE FACILITY TO DUMPSTER ALONG VA APPROVED

ROUTE IN ENCLOSED DUMPSTER CART DESIGNED FOR SUCH PURPOSED

WITH A LID.

ALL MATERIAL, DEBRIS AND HAZARDOUS MATERIALS SHALL BE PROPERLY

STORED IN DESIGNATED AREAS AND APPROVED CONTAINERS. FLAMMABLE

MATERIALS SHALL NOT BE STORED IN THE FACILITY.

PROVIDE CONTAINMENT CART FOR ABOVE CEILING ACCESS OUTSIDE

PROJECT BOUNDARY.

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

K.

L.

M.

N.

O.

P.

INFECTION CONTROL GENERAL NOTES

PHASING GENERAL NOTES

A

B

C

PROJECT AREAS TO BE OCCUPIED BY STAFF AND VETERANS THROUGHOUT

CONSTRUCTION.

PROJECT SHALL BE COMPLETED REGULAR BUSINESS HOURS, 6:00 AM TO 6:00

PM. COORDINATE WITH COR. ALL WORK TO BE COMPLETED AND OPEN FOR

PUBLIC USE AT THE END OF EACH NIGHT'S WORK.

REFER TO SPECIFICATION 01 00 00 FOR INFORMATION ON WORK DURATION

FOR EACH PHASE AND AREA OF WORK.

INFECTION CONTROL PLAN NOTES #

PROVIDE TEMPORARY 1 HR FIRE RATED SMOKE BARRIER WALL

CONSTRUCTION PER NFPA 241. REFER TO DETAIL 1/GI102.

PROVIDE TEMPORARY INFECTION CONTROL CONSTRUCTION DOOR. REFER

TO ELEVATION 3/GI102.

PROVIDE TEMPORARY INFECTION CONTROL BARRIER WALL CONSTRUCTION.

REFER TO DETAIL 2/GI102.

IC/PHASING LEGEND

TEMPORARY WALLS. SEE PLAN AND

PLAN NOTES

TEMPORARY CONSTRUCTION ACCESS

DOORS

REFERENCE AREA FOR ABOVE

CEILING WORK ON FLOOR BELOW.

REFER TO ENGINEERING DRAWINGS

FOR FULL SCOPE OF WORK

BEYOND PROJECT BOUNDARY

PROJECT BOUNDARY

PHASE 2 OF 2

PHASE 1 OF 2

TEMPORARY IC BARRIER WALL

CONSTRUCTION (DUST WALL)

5/8" TYPE X GYP BD

3 5/8" STEEL STUDS @ 16"

O.C.

BEAD OF CONT. SEALANT

6-MIL FIRE RETARDENT POLY

INTERIOR SIDE

CEILING, RE: RCP SHEETS

2" DEEP LEG 3 5/8" STEEL SLIP TRACK

3 5/8" STEEL STUD TRACK

4" M

IN

CONTINUOUSLY ADHERE 6-MIL. FIRE

RETARDANT POLY TO DECK WITH TAPE

CONTINUOUSLY ADHERE FIRE RETARDENT

POLY TO FLOOR WITH TAPE

EXISTING DECK

CONSTRUCTION

SIDE

OCCUPIED

SIDE

PUBLIC

SIDE

1 HOUR FIRE RATED DOOR ASSEMBLY, FRAME

WITH SEALS AND HARDWARE

TRIATEK MONITOR OR EQUIVALENT

HAND SANITIZER

SEAL ALL EDGES WITH TAPE

SEAL ALL EDGES WITH TAPE

REFER TO TEMPORARY BARRIER TYPE

FOR REQUIRED CONDITION TO

STRUCTURE ABOVE

VA / OSHA TEMPORARY SIGNAGE

CONTINUOUS FIRESAFE SEALANT

TOP AND BOTTOM, & BOTH SIDES

3 1/2" SOUND ATTENUATION

BATT.

5/8" TYPE X GYPSUM BOARD, BOTH

SIDES

3 5/8" METAL STUD @ 16" O.C.

WITH RUNNER CHANNELS ALONG

TOP AND BOTTOM

CONSTRUCTION

SIDE

PUBLIC

SIDE

6 MIL. FIRE RETARDANT VISQUEEN

MEMBRANE. CONTINUOUSLY

ADHERE TO THE STRUCTURAL DECK

ABOVE AND TO THE FLOOR BELOW

WITH TAPE.

UNDERSIDE OF STRUCTURAL DECK

UL LISTING:

U465

COORDINATE WITH EXISTING

CEILING

KEY PLAN

N

G

A

B

C

D

E

F

H

1 2 3 4 5 6 7 8 9 10 11

C

LE

A R

6'

CLEAR

6' - 0"

CLEAR

6' - 0"

C

LE

A R

6'

C

LE

A R

6'

PHASE 1

PHASE 1 PHASE 2

PACT TOILET

CW183

STORAGE

CW160G

TELE-HEALTH

CW160B

TELE-RETINAL

CW160A

TEAM WORK AREA

CW160

TELE-HEALTH

CW160D

HYBRID EXAM

CW160E

SOILED

CW161

CLEAN

CW162

HYBRID EXAM

CW186

HYBRID EXAM

CW150S

HYBRID EXAM

CW150RHYBRID EXAM

CW150Q

WOMEN EXAM

CW150P

WOMEN EXAM

CW150N

WOMEN'S TOILET

CW150O

HYBRID EXAM

CW150M

HYBRID EXAM

CW150L

HYBRID EXAM

CW150K

HYBRID EXAM

CW150J

PROCEDURE

CW150H

PROCEDURE TOILET

CW150I

HYBRID EXAM

CW150G

HYBRID EXAM

CW150F

HYBRID EXAM

CW150E

HYBRID EXAM

CW150D

HYBRID EXAM

CW140Q

HYBRID EXAM

CW150C

HYBRID EXAM

CW150B

HYBRID EXAM

CW150A

NURSE MANAGER

CW152

HAC

CW171

PATIENT CORRIDOR

CWC9

PATIENT CORRIDOR

CWC4

WOMEN EXAM

CW140J

WOMEN TOILET

CW140I

WOMEN EXAM

CW140H

HYBRID EXAM

CW140G PACT TOILET

CW140U

HYBRID EXAM

CW140F

HYBRID EXAM

CW140E

HYBRID EXAM

CW140D

HYBRID EXAM

CW140C

HYBRID EXAM

CW140B

HYBRID EXAM

CW140A

HT / WT

CWC6-A

HYBRID EXAM

CW140T

HYBRID EXAM

CW140S

HYBRID EXAM

CW140R

HT / WT

CWC4-A

PACT TOILET

CW151

HYBRID EXAM

CW140P

HYBRID EXAM

CW140O

HYBRID EXAM

CW140N

HYBRID EXAM

CW140M

HYBRID EXAM

CW140L

HYBRID EXAM

CW140K

FAMILY TOILET

CW174

PATIENT CORRIDOR

CWC6

TEAM WORK AREA

CW140

TEAM WORK AREA

CW150

STAFF LOCKER

CW157

STAFF FEMALE

TOILET

CW158

STAFF MALE TOILET

CW159

PACT WORKROOM

CW142

PACT WORKROOM

CW143

CLEAN

CW144

STAFF FEMALE

TOILET

CW145

STAFF MALE TOILET

CW146

EQUIPMENT

CW147

SHAFT

SOILED

CW149

PACT WORKROOM

CW148

SHAFT

STAFF LOUNGE /

CONFERENCE /

TRAINING ROOM

CW155

STAIR NO. 3

STAFF CORRIDOR

CWC5

FAMILY TOILET

CW175

HT / WT

CWC9-A

FEMALE PUBLIC

TOILET

CW170B

MALE PUBLIC

TOILET

CW170A

STAIR NO. 1

MEDICATION

CW150T

MEDICATION

95-A

WHEELCHAIR

CWC1E

C H

E C

K -I

N K

IO

S

K

C W

C F

VOLUNTEER

CWC1D

RECEPTION

CW180

WAITING AREA

CW170

CORRIDOR

CWC1

MEDICATION

CW160-A

HAC

CW187

OFFICE MANAGER

CW153

CHIEF MEDICAL

OFFICER

CW154

SHARED MEDICAL

APPT

CW185

SHARED MEDICAL

APPT

CW184

STORAGE

CW184A

STORAGE

CW185A

PACT TOILET

CW186

DATA

CW169

ENTRANCE

VESTIBULE

CWC1A

TOILET VESTIBULE

CWC15A

CORRIDOR

CWC14

CORRIDOR

CWC13

C

LE

A R

6'

CLE

AR6'

- 0

N

ELECTRICAL

CW160F

ELECTRICAL

CW160C

WAITING AREA

CW170

Project Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

N O T F

N

STR

U C

TIO

N o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

Building Number

C U s e rs \l s p lic h a l\ D o c u m e n ts \1

.1

V

A M e m p h is

B ld g

P ri m a ry

C a re ls p lic h a l.

rv t

/1 /2

:1

:2

P M

GI102

INFECTION CONTROL/PHASING

PLANGUIDON DESIGN, INC

1221 N PENNSYLVANIA STEET, SUITE 200

INDIANAPOLIS, IN 46202

317.800.6388

ANDREW SCHAEWE

CMTA CONSULTING ENGINEERS, INC

10411 MEETING STREET

PROSPECT, KY 40059

502.326.3085

ANDREW MYERS

RENOVATE BUILDING 1 PRIMARY

CARE

MEMPHIS VAMC

614-17-113

RYAN STEPHENS,

COR MEMPHIS, TN

05/01/2019 AWS JP

BID SET

FULLY SPRINKLERED

SCALE: 1 1/2" = 1'-0"GI102

2 TEMPORARY INFECTION CONTROL BARRIER WALL CONSTRUCTION

SCALE: 1/4" = 1'-0"GI102

3 TEMPORARY WALL CONSTRUCTION ELEVATION

SCALE: 1 1/2" = 1'-0"GI102

1 TEMPORARY 1 HR FIRE RATED SMOKE BARRIER WALL CONSTRUCTION NFPA 241

SCALE: 3/32" = 1'-0"GI102

4 FIRST FLOOR - INFECTION CONTROL / PHASING PLAN

STATEMENT OF BID ITEMS

ALTERNATE A - DEDUCT TERRAZO FLOORING

REMOVE ALL TERRAZO FLOORING AS INDICATED AND REPLACED BY LVT TO

BE SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR. AREA INCLUDE

BUT ARE NOT LIMITED TO ENTRANCE CORRIDOR. REFER TO AF102 FOR THE

EXTENT OF FLOOR COVERAGE & DESIGN.

ALTERNATE B - DEDUCT SYSTEMS FURNITURE

REMOVE ALL SYSTEMS FURNITURE INDICATED TO BE SUPPLIED AND

INSTALLED BY THE GENERAL CONTRACTOR. AREA INCLUDE BUT ARE NOT

LIMITED TO PATIENT EXAM ROOMS, TEAM WORK AREAS, PACT WORKROOMS,

SHARED MEDICAL APPT ROOMS AND TELE HEALTH ROOMS.

ALTERNATE C - DEDUCT MAIN ENTRANCE VESTIBULE

REMOVE ALL WORK AT THE MAIN ENTRANCE VESTIBULE INDICATED TO BE

SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR WITH THE

EXCEPTION OF ALL WORK ASSOCIATED WITH PLAN NOTE 8 ON AD101 & PLAN

NOTE 6 ON AS101.

ALTERNATE D - DEDUCT SLIDING DOOR (STAFF SIDE)

REMOVE APPROXIMATELY 42 SLIDING DOORS, FROM THE TEAM WORK AREA

SIDE OF ALL MEDICAL EXAM AND TELE HEALTH ROOMS AND REPLACE WITH

STANDARD SWINGING 36" DOORS.

ALTERNATE E - DEDUCT SLIDING DOOR (PATIENT SIDE)

REMOVE APPROXIMATELY 39 SLIDING DOORS, FROM THE PAITENT CORRIDOR

SIDE OF ALL MEDICAL EXAM, PRODECURE AND TELE HEALTH ROOMS AND

REPLACE WITH STANDARD SWINGING 42" DOORS.

A

B

C

D

E

BID ITEM #1: BASE BID.

BID ITEM #2: ALL WORK AS DESCRIBED FOR BID ITEM #1 ABOVE MINUS THAT

PORTION OF WORK SHOWN AS ALTERNATE A.

KEY PLAN

N

G

A

B

C

D

E

F

H

1 2 3 4 5 6 7 8 9 10 11

PACT TOILET

CW183

STORAGE

CW160G

TELE-HEALTH

CW160B

TELE-RETINAL

CW160A

TEAM WORK AREA

CW160

TELE-HEALTH

CW160D

HYBRID EXAM

CW160E

SOILED

CW161

CLEAN

CW162

HYBRID EXAM

CW186

HYBRID EXAM

CW150S

HYBRID EXAM

CW150R

HYBRID EXAM

CW150Q

WOMEN EXAM

CW150P

WOMEN EXAM

CW150N

WOMEN'S TOILET

CW150O

HYBRID EXAM

CW150M

HYBRID EXAM

CW150L

HYBRID EXAM

CW150K

HYBRID EXAM

CW150J

PROCEDURE

CW150H

PROCEDURE TOILET

CW150I

HYBRID EXAM

CW150G

HYBRID EXAM

CW150F

HYBRID EXAM

CW150E

HYBRID EXAM

CW150D

HYBRID EXAM

CW140Q

HYBRID EXAM

CW150C

HYBRID EXAM

CW150B

HYBRID EXAM

CW150A

HAC

CW171

PATIENT CORRIDOR

CWC9

PATIENT CORRIDOR

CWC4

WOMEN EXAM

CW140J

WOMEN TOILET

CW140I

WOMEN EXAM

CW140H

HYBRID EXAM

CW140G

PACT TOILET

CW140U HYBRID EXAM

CW140F

HYBRID EXAM

CW140E

HYBRID EXAM

CW140D

HYBRID EXAM

CW140C

HYBRID EXAM

CW140B

HYBRID EXAM

CW140A

HT / WT

CWC6-A

HYBRID EXAM

CW140T

HYBRID EXAM

CW140S

HYBRID EXAM

CW140R

HT / WT

CWC4-A

PACT TOILET

CW151

HYBRID EXAM

CW140P

HYBRID EXAM

CW140O

HYBRID EXAM

CW140N

HYBRID EXAM

CW140M

HYBRID EXAM

CW140L

HYBRID EXAM

CW140K

FAMILY TOILET

CW174

PATIENT CORRIDOR

CWC6

TEAM WORK AREA

CW140

TEAM WORK AREA

CW150

STAFF LOCKER

CW157

STAFF FEMALE

TOILET

CW158

STAFF MALE TOILET

CW159

PACT WORKROOM

CW142

PACT WORKROOM

CW143

CLEAN

CW144

STAFF FEMALE

TOILET

CW145

STAFF MALE TOILET

CW146

EQUIPMENT

CW147

SHAFT

SOILED

CW149

PACT WORKROOM

CW148

SHAFT

STAFF LOUNGE /

CONFERENCE /

TRAINING ROOM

CW155

STAIR NO. 3

STAFF CORRIDOR

CWC5

FAMILY TOILET

CW175

HT / WT

CWC9-A

HAC

CW187

FEMALE PUBLIC

TOILET

CW170B

MALE PUBLIC

TOILET

CW170A

STAIR NO. 1

MEDICATION

CW150T

MEDICATION

95-A

WHEELCHAIR

CWC1E

CHECK-IN KIOSK

CWC1F

VOLUNTEER

CWC1D

RECEPTION

CW180

WAITING AREA

CW170

CORRIDOR

CWC1

MEDICATION

CW160-A

OFFICE MANAGER

CW153

NURSE MANAGER

CW152

CHIEF MEDICAL

OFFICER

CW154

SHARED MEDICAL

APPT

CW185

SHARED MEDICAL

APPT

CW184

STORAGE

CW184A

STORAGE

CW185A

PACT TOILET

CW186

DATA

CW169

ENTRANCE

VESTIBULE

CWC1A

TOILET VESTIBULE

CWC15A

BBBB

B

B

B

B

A

C

BB

B

B

B

ELECTRICAL

CW160C

ELECTRICAL

CW160F

N

WAITING AREA

CW170

B

B

B

B

B

B

B

CW140BA

CW140BB

HYBRID EXAM

CW140B

PATIENT CORRIDOR

CWC6

TEAM WORK AREA

CW140

E

D

B

B

Project Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

N O T F

N

STR

U C

TIO

N o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

Building Number

C U s e rs \l s p lic h a l\ D o c u m e n ts \1

.1

V

A M e m p h is

B ld g

P ri m a ry

C a re ls p lic h a l.

rv t

/1 /2

:1

:4

P M

GI103

BID ALTERNATES

GUIDON DESIGN, INC

1221 N PENNSYLVANIA STEET, SUITE 200

INDIANAPOLIS, IN 46202

317.800.6388

ANDREW SCHAEWE

CMTA CONSULTING ENGINEERS, INC

10411 MEETING STREET

PROSPECT, KY 40059

502.326.3085

ANDREW MYERS

RENOVATE BUILDING 1 PRIMARY

CARE

MEMPHIS VAMC

614-17-113

RYAN STEPHENS,

COR MEMPHIS, TN

05/01/2019 AWS JP

BID SET

FULLY SPRINKLERED

SCALE: 1/8" = 1'-0"GI103

1 FIRST FLOOR - BID ALTERNATE PLAN

SCALE: 3/8" = 1'-0"GI103

2 ENLARGED PLAN @ TYPICAL HYBRID EXAM - BID ALTERNATE

CW132

CW133

CW134CW135

CW128

CW127ACW127

CW124

CW126C

CW126E

CW114

CW173

CW166A

CW170

CW166

CW120B

CW119

P-7P-6

CW110

NO 2

CW123

CW111A

CW105

CW120

CW120A

CW166B

CW113

CW165

CW171

CW172

CW126A

126D

CW127B

CW126

CW125 CW123B CW123A

CW139

CW138CW137CW136

CW104A

CW102BCW101B

NO 1

NO 3

CW175CW176CW177

CW178

CW179

CW180

CW140

CW140B

CW140A

CW140

CW141CW142

CW143

CW144

CW145CW146CW147

CW148

CW150

CW149

CW152C

CW152BCW152A

CW152E

CW152

CW151

CW149B

CW149A

CW149E

CW149C

CW183

CW191

CW191A

CW187

CW186CW185 CW185A

CW185B

CW190

CW189

CW184

CW182

CW181

CW174

CW196

CW196A

CW195

CW160A

CW160C

CW160D

CW160B

CW154

CW160

CW163

CW164

CW197

CW194B

CW194

CW192

CW194B CW194C

CW193

CW140D

CW140C

CW194A

FECELEVATOR

ELEVATOR

ELEVATOR

ELEVATOR

IMMUNOLOGY

LOBBY

TOILET

PTSD OFFICE

PTSD OFFICE

PTSD RESIDENTIAL

OFFICE

AGENT

CASHIER

ELIGIBILITY /

TRAVEL OFFICE

ELIGIBILITY /

TRAVEL OFFICE

PATIENT

ADVOCATE OFFICE

OFFICE

TELE OPERATOR

TESTINGTESTING

E C

OFFICE

MENS

TOILET

EXAM

ELEVATORELEVATOR

T CE C

ELEVATORELEVATOR

STAIR

YELLOW

WAITING

LOW VISION EXAM

EXAM

EYE CLINIC WAITING

EXAM

STORAGE

HAC

WOMENS TOILET

ELIGIBILITY OFFICE

TELECOM STORAGE HEAD CLERK

HEALTH

BENEFIT

SECTION OFFICE

ELIGIBILITY /

TRAVEL OFFICE

PATIENT

ADVOCATE OFFICE

PATIENT

ADVOCATE

OFFICE

SOCIAL

WORKER ADMIN

OFFICE

PTSD OFFICEPTSD OFFICE

EXAMPTSD OFFICEPTSD OFFICE

CORRIDOR

OFFICE

OPTOMETRY OFFICE

TOILET

ULTRASOUND-3

READINGREADING RM

CORRIDOR

STORAGE

CLINICAL

PHARMACY

EDUCATIONAL

CO-ORDINATOR

OPTOMETRY OFFICE

TC

TC

ELECTRICAL

STAIR

ELEVATORELEVATOR

STORAGE

CASE LAB

HEMATOLOGY

CASE LAB

CHEMISTRY SUPV

WOMENS TOILET

CARE LABANCILLARY TESTING OFFICE

FILES

STORAGE RM

NIGHT SUPVSUPV

TELECOM

SHAFT

SPECIAL

CARE LAB

CARE/PED

TECH OFFICE

HAC

SHAFT

SUPPLYOFFICEOFFICEMICROSCOPIC TEACHINGRESIDENTS

FROZEN

SECTION

CLOSET

BREAK RM

EXAM

ELEVATOR

WAITING

ACCESSION AREA

TOILET TOILET

BLOOD DWG

STORAGE

STORAGERECEPTION OFFICE

COPY

PGM

ASST

ADMINISTRATIVE CLERKS-4

SECYCHIEF

OFFICE-1PATHOLOGY OFFICE-2OFFICE-3OFFICE-4OFFICE-5

OFFICE

ELECTRICAL

FILE

B-V CODE

EXPANSION

CO-ORDINATOR

BREAK RM

MENS TOILET

BLOOD BANK

TB

REFMYC

OFFICE

MICROBIOLOGY

STAIR

AUTOCLAVE

FLOW

CYTOMETER

OFFICE

PCR RM

CONFERENCE

RECEPTION

MICROSCOPE RM

CASE LAB

HAZARDOUS MATERIAL REMOVAL LEGEND

PROJECT BOUNDARY

BEYOND PROJECT BOUNDARY

HAZARDOUS MATERIAL REMOVAL GENERAL NOTES

HAZMAT REMOVAL NOTES APPLY TO ENTIRE ROOMS. CONTRACTOR SHALL

IDENTIFY ALL MATERIALS DESCRIBED BY NOTE IN EACH ROOM AND REMOVE

ACCORDING TO SAFETY STANDARDS. REFERENCE SPECIFICATION 02 41 00

DEMOLITION & 02 82 11 TRADITIONAL ASBESTOS ABATEMENT AND

ATTACHMENTS FOR ADDITIONAL INFORMATION.

ALL HAZARDOUS MATERIALS SHALL BE REMOVED IN COMPLIANCE WITH

APPLICABLE CODES AND LAWS.

THE CONTRACTOR IS RESPONSIBLE TO VERIFY THE HAZARD(S) AND LEVEL OF

PROTECTION REQUIRED FOR ALL EMPLOYEES OR SUBCONTRACTORS TO

COMPLETE THE CONSTRUCTION WORK.

PROVIDE ABATEMENT OF VCT AND FLOORING MASTIC WITHIN HATCHED AREA.

BASED ON THE DATE OF THE EXISTING CONSTRUCTION IT IS ASSUMED LEAD

PAINT IS WITHIN THE PROJECT AREA. CONDUCT DEMOLITION OF THE

EXISTING SPACE WITH THE ASSUMPTION OF LEAD PAINT ON EXPOSED

PLASTER WALLS AND PAINTED SURFACES. REFER TO SPECIFICATION

SECTION 02 83 33.13 LEAD-BASED PAINT REMOVAL, DISPOSAL AND FOR

ADDITIONAL INFORMATION.

BASED ON THE DATE OF THE EXISTING CONSTRUCTION AND UNDERSTANDING

OF THE FACILITY, IT IS POSSIBLE THAT THERE IS LEAD PAINT WITHIN THE

PROJECT AREA. ON AREAS OF EXISTING CONSTRUCTION THAT CONTAIN

LEAD PAINT, DO NOT PROVIDE LEAD ABATEMENT. PROVIDE LEAD PAINT

SURFACE STABILIZATION ON EXISTING TO REMAIN WORK IS DONE.

CONTRACTOR TO USE MEASURES FOR PROTECTION AND TO MINIMIZE PAINT

DEBRIS.

CONTRACTOR TO SUBMIT LEAD SURFACES STABILIZATION PLAN AND

PROCEDURES PRIOR TO COMMENCING WORK. SUBMITTAL SHALL BE IN

ACCORDANCE WITH SPECIFICATIONS.

A

B

C

D

E

F

G

HAZARDOUS MATERIAL REMOVAL PLAN NOTES #

1 THE CONTRACTOR SHALL REMOVE ALL ASBESTOS CONTAINING BLACK MASTIC

AND 12" NON-ASBESTOS FLOOR TILE WITHIN THE PROJECT BOUNDARY,

UNLESS OTHERWISE NOTED.

KEY PLAN

N

* * NOTE * *

PER ASBESTOS SAMPLING REPORT BY

CASTLE HILLL ASSOCIATES, DATED

NOVEMBER 11, 2017.

BLACK RESIDUAL MASTIC ASBESTOS

CONTAINING MATERIAL FOUND UNDER

YELLOW MASTIC FOR NON-ASBESTOS 12"

FLOOR TILE THROUGHOUT RENOVATION

AREA FOOTPRINT EXCEPT IN RESTROOMS.

G

A

B

C

D

E

F

H

1 2 3 4 5 6 7 8 9 10 11

N

ENTRANCE

VESTIBULE

CWC1A

Project Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

N O T F

N S

TR

U C

TIO

N o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

Building Number

C U s e rs \l s p lic h a l\ D o c u m e n ts \1

.1

V

A M e m p h is

B ld g

P ri m a ry

C a re ls p lic h a l.

rv t

/1 /2

:1

:4

P M

HA101

HAZARDOUS MATERIAL REMOVAL

PLANGUIDON DESIGN, INC

1221 N PENNSYLVANIA STEET, SUITE 200

INDIANAPOLIS, IN 46202

317.800.6388

ANDREW SCHAEWE

CMTA CONSULTING ENGINEERS, INC

10411 MEETING STREET

PROSPECT, KY 40059

502.326.3085

ANDREW MYERS

RENOVATE BUILDING 1 PRIMARY

CARE

MEMPHIS VAMC

614-17-113

RYAN STEPHENS,

COR MEMPHIS, TN

05/01/2019 AWS JP

BID SET

FULLY SPRINKLERED

SCALE: 1/8" = 1'-0"HA101

1 FIRST FLOOR - HAZARDOUS MATERIAL PLAN

Sheets
GI000 - COVER SHEET

File details come from the government source that posted it. Updated .