36C24920R0008-007.pdf
PDF Posted
- Solicitation number
- 36C24920R0008
About this file
This document includes a federal contract solicitation notice and construction drawings for a hospital renovation project. The Memphis VA Medical Center is seeking a contractor experienced in healthcare construction to renovate Building 1's clinical lab for Project 614-17-112. The estimated value of the construction work is between $5-10 million. Services required include general construction, plumbing, mechanical, electrical, and exterior work in accordance with provided specifications and drawings. As this project will take place within an active hospital, infection control and other medical environment protocols must be followed. The solicitation is anticipated to be released by November 6, 2019 following a Lowest Price Technically Acceptable source selection process. This is a 100% SDVOSB set-aside awarded under 38 U.S.C. 8127(d). The awarded contractor must be verified in the CVE database and have an active SAM registration. Questions regarding this opportunity must be submitted in writing with the relevant project details included.
36C24920R0008 17.1055 - 2019.05.01.02_General Sheets.pdf
View the file
Other files
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
N O T F
O R
C
N S
TR
U C
TIO
N o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
Building Number
C U s e rs \l s p lic h a l\ D o c u m e n ts \1
.1
V
A M e m p h is
B ld g
P ri m a ry
C a re ls p lic h a l.
rv t
/1 /2
:0
:3
P M
GI000
COVER SHEET
GUIDON DESIGN, INC
1221 N PENNSYLVANIA STEET, SUITE 200
INDIANAPOLIS, IN 46202
317.800.6388
ANDREW SCHAEWE
CMTA CONSULTING ENGINEERS, INC
10411 MEETING STREET
PROSPECT, KY 40059
502.326.3085
ANDREW MYERS
RENOVATE BUILDING 1 PRIMARY
CARE
MEMPHIS VAMC
614-17-113
RYAN STEPHENS,
COR MEMPHIS, TN
05/01/2019 AWS JP
BID SET
FULLY SPRINKLERED
Contact:Contact: Contact:
CMTA CONCULTING ENGINEERS, INC.
Andrew Myers
Project Engineer
MECHANICAL,
ELECTRICAL &
PLUMBING
MEMPHIS VAMC
Sonya Ellis
COR
1030 Jefferson Avenue Memphis, TN 38104 p: 901.523.8990 x 5026 e: sonya.ellis@va.gov
OWNER
GUIDON DESIGN INC.
Andrew Schaewe
Project Manager
1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202 p: 317.800.6388 x 141 e: aschaewe@guidondesign.com
ARCHITECT
10411 Meeting Street Prospect, KY 40059 p: 502.326.3085 e: amyers@cmtaegrs.com
CAMPUS MAP
VICINITY MAP
BUILDING SITE
N
N
N
SHEET LIST
SHEET NUMBER SHEET NAME
GENERAL
GI000 COVER SHEET
GI101 LIFE SAFETY PLAN
GI102 INFECTION CONTROL/PHASING PLAN
GI103 BID ALTERNATES
HA101 HAZARDOUS MATERIAL REMOVAL PLAN
ARCHITECTURAL
AS001 ARCHITECTURAL ABBREVIATIONS AND GENERAL NOTES
AS002 ARCHITECTURAL SYMBOLS AND WALL TYPES
AD101 FIRST FLOOR DEMOLITION PLAN
AD401 ENLARGED DEMOLITION PLAN
AS101 FIRST FLOOR ARCHITECTURAL PLAN
AS102 FIRST FLOOR DIMENSION PLAN
AS111 FIRST FLOOR REFLECTED CEILING PLAN
AS401 ENLARGED PLANS
AS402 ENLARGED PLANS
AS403 ENLARGED REFLECTED CEILING PLAN & DETAILS
AS501 DETAILS
AS601 DOOR SCHEDULE
AS801 INTERIOR ELEVATIONS
AS802 INTERIOR ELEVATIONS
AS803 INTERIOR ELEVATIONS
AS804 INTERIOR ELEVATIONS
AS811 INTERIOR SECTIONS AND DETAILS
AS901 SIGNAGE PLAN
AS902 SIGNAGE TYPE
AS911 3D ISOMETRICS
AF101 FIRST FLOOR WALL FINISH PLAN
AF102 FIRST FLOOR FLOOR FINISH PLAN
AF601 FINISHES AND EQUIPMENT SCHEDULE
AQ101 EQUIPMENT FLOOR PLAN
AQ102 ENLARGED EQUIPMENT PLANS
MECHANICAL
ML100 MECHANICAL LEGEND AND GENERAL NOTES
MD100 PARTIAL GROUND FLOOR PLAN - MECHANICAL DEMOLITION
MD101 PARTIAL FIRST FLOOR PLAN - AIR DISTRIBUTION DEMOLITION
MD102 PARTIAL FIRST FLOOR PLAN - HYDRONICS DEMOLITION
MD103 PARTIAL SECOND FLOOR PLAN - MECHANICAL DEMOLITION
MD104 MECHANICAL ROOF PLAN - DEMOLITION
MD105 MECHANICAL FOURTH FLOOR ROOF PLAN - DEMOLITION
MH100 PARTIAL BASEMENT FLOOR PLAN - MECHANICAL
MH101 PARTIAL FIRST FLOOR PLAN - AIR DISTRIBUTION
MH102 PARTIAL SECOND FLOOR PLAN - MECHANICAL
MH103 MECHANICAL ROOF PLAN
MP100 PARTIAL GROUND FLOOR PLAN - HYDRONICS
MP101 PARTIAL FIRST FLOOR PLAN - HYDRONICS
MH200 MECHANICAL DETAILS
MH201 MECHANICAL DETAILS
MH202 MECHANICAL DETAILS
MH203 MECHANICAL CONTROLS SCHEMATICS
MH204 MECHANICAL CONTROLS SCHEMATICS
MS100 MECHANICAL SCHEDULES
ELECTRICAL
ES101 ELECTRICAL LEGEND
ED101 PARTIAL FIRST FLOOR PLAN - ELECTRICAL DEMOLITION
ED102 ROOF PLAN - ELECTRICAL DEMOLITION
ES201 PARTIAL FIRST FLOOR PLAN - LIGHTING
ES301 PARTIAL FIRST FLOOR PLAN - POWER
ES302 PARTIAL ROOF PLAN - POWER
ES401 PARTIAL FIRST FLOOR PLAN - SYSTEMS
ES500 PARTIAL GROUND FLOOR PLAN - ELECTRICAL INTERCONNECTIONS
ES501 PARTIAL FIRST FLOOR PLAN - ELECTRICAL INTERCONNECTIONS
ES502 PARTIAL SECOND FLOOR PLAN - ELECTRICAL INTERCONNECTIONS
ES601 POWER DISTRIBUTION RISER DIAGRAM AND DETAILS
ES701 LIGHT FIXTURE SCHEDULE AND DETAILS
ES702 PANELBOARD SCHEDULES
ES801 TELECOMMUNICATION DETAILS
ES802 ELECTRICAL DETAILS
PLUMBING
PL101 PLUMBING LEGEND, SCHEDULES & DETAILS
PD101 GROUND FLOOR - PLUMBING DEMOLITION PLAN
PD102 FIRST FLOOR - PLUMBING DEMOLITION PLAN
PP101 GROUND FLOOR - PLUMBING PLAN
PP102 FIRST FLOOR - PLUMBING PLAN
PP103 SANITARY WASTE AND VENT RISER DIAGRAM NO.1
PP104 SANITARY WASTE AND VENT RISER DIAGRAM NO.2
PP105 SANITARY WASTE AND VENT RISER DIAGRAM NO.3
FIRE PROTECTION
FX101 FIRE PROTECTION NOTES & DETAILS
FX102 FIRST FLOOR - FIRE PROTECTION PLAN
MEMPHIS VA MEDICAL CENTER
MEMPHIS, TENNESSEE
RENOVATE BUILDING 1 PRIMARY CARE
VA PROJECT #614-17-113
BID SET
PROJECT LOCATION
PROJECT LOCATION
PROJECT LOCATION
Revisions: Date:
CODE ANALYSIS LEGEND
TOTAL OCCUPANCY
FEC
EXIT
OCCUPANCY LOAD FACTOR
EXITS REQUIRED
SQUARE FOOTAGE
OCCUPANCY TYPE
EGRESS EXIT SIGNAGE
FIRE EXTINGUISHER CABINET
DIAGONAL DISTANCE
EXIT SEPARATION DISTANCE
EGRESS PATH
2 HR - FIRE SEPARATION
1 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
B
1500 SF
REFER TO VA MANUAL PG-18-3 FOR ADDITIONAL CODES, STANDARDS, GUIDELINES AND
REGULATIONS, BELOW LISTING IS NOT COMPREHENSIVE.
ICC, INTERNATIONAL BUILDING CODES, 2018 EDITION (IBC)
ASCE-07-10
ACI 318-11
ACI 530-11
AISC 341-10
AISC 360-10
PCI MNL 120-10, DESIGN HANDBOOK
NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2013 EDITION
NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2016 EDITION
NFPA 14, STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEM, 2016
EDITION
NFPA 20, STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE
PROTECTION, 2016 EDITION
NFPA 24, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND
THEIR APPURTENANCE, 2016 EDITION.
NFPA 54 NATOINAL FUEL GAS CODE, 2015 EDITION
NFPA 70, NATIONAL ELECTRIC CODE, 2014 EDITION
NFPA 72, NATIONAL FIRE ALARM CODE, 2016 EDITION
NFPA 75, STANDARD FOR THE PROTECTION OF ELECTRICAL COMPUTER/DATA
PROCESSING EQUIPMENT, 2017 EDITION
NFPA 77, RECOMMENDED PRACTICE ON STATIC ELECTRICITY, 2014 EDITION
NFPA 80, STANDARD FOR FIRE DOORS AND FIRE WINDOWS, 2016 EDITION
NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING
SYSTEMS, 2015 EDITION.
NFPA 92, STANDARD FOR SMOKE CONTROL SYSTEMS, 2015 EDITION
NFPA 99, STANDARD FOR HEALTHCARE FACILITIES, 2015 EDITION
NFPA,99B, STANDARD FOR HYPOBARIC FACILITIES, 2015 EDITION
NFPA 101, LIFE SAFETY CODE, 2015 EDITION
NFPA 110, STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS
NFPA 220, STANDARD TYPES OF BUILDING CONSTRUCTION, 2015 EDITION.
NFPA 780, STANDARD FOR INSTALLATION OF LIGHTING PROTECTION SYSTEMS, 2017
EDITION
NFPA 54 TYPE 2 CLOTHES DRYER UL 705 DEDPY, 2015 EDITION
MOST RECENT EDITION OF NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA
5000 AND NFPA 900
ASHRAE 90.1-2016 HVAC SYSTEMS
ANSI A117.1-2009 STANDARD ON ACCESSIBLE & USABLE BUILDINGS AND FACILITIES
2010 ADA STANDARDS FOR ACCESSIBLE DESIGN
OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS
ENERGY POLICY ACT OF 2005 (EPACT)
EXECUTIVE ORDER 13423: STRENGTHENING FEDERAL ENVIRONMENTAL, ENERGY, AND
TRANSPORTATION MANAGEMENT.
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD
STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL
INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
VA BARRIER FREE DESIGN GUIDE PG-18-13, ABAAS
ARCHITECTURAL, AUGUST 1, 2014
ASBESTOS ABATEMENT, JULY 2011
CMP SCHEDULE AND RISK MANAGEMENT, VOL. 1 & 2, DECEMBER 2012
ELECTRICAL, DECEMBER 2015
ENERGY SUSTAINABILITY, MAY 2014
EQUIPMENT, JANUARY 2006
ESTIMATING, MARCH 8, 2011
NFPA INTERIM GUIDANCE FOR PROJECTS, PG-18-17, SEPTEMBER 30, 2010
FIRE PROTECTION, SEVENTH EDITION REVISED DECEMBER 2015
HVAC FOR NEW, REPLACEMENT, ADD. AND REN. OF EXIST. CA FACILITIES, MARCH 2011
INTERIOR DESIGN, MAY 2008
PHYSICAL SECURITY DESIGN MANUAL, JANUARY 2015
PLUMBING, NOVEMBER 2014
STRUCTURAL, FEBRUARY 1, 2014
WAY FINDING AND SIGNAGE, INTERIOR, DECEMBER 2012
SEISMIC DESIGN REQUIREMENTS, H-18-8, AUGUST 2013
ENVIRONMENTAL PLANNING GUIDANCE PG-18-17 NEPA INTERIM GUIDELINES FOR
PROJECTS SEPTEMBER 30, 2010
ELEVATOR DESIGN MANUAL, AUGUST 2016
EPA GUIDELINES CHECKLIST
VA DESIGN MANUALS PG-18-10:
GOVERNING CODES:
CODE CRITERIA
GENERAL: THIS SUMMARY OF CODE REQUIREMENTS IS BASED PRIMARILY ON NFPA 101 (LSC). DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE IDENTIFIED. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES.
NOTES:
CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
CODE REVIEW
THE 2018 EDITION OF THE LIFE SAFETY CODE, NFPA 101, HAS BEEN USED TO REVIEW THIS PROJECT FOR COMPLIANCE WITH THE FIRE AND LIFE SAFETY REQUIREMENTS. FOR FEATURES NOT ADDRESSED BY NFPA 101 AND THE REFERENCED NATIONAL FIRE CODES, THE 2018 EDITION OF THE INTERNATIONAL
BUILDING CODE HAS BEEN USED.
PROJECT SCOPE
THE PROJECT SCOPE INCLUDES THE RENOVATION OF BUILDING 1, FIRST FLOOR PRIMARY CARE CLINIC. THE NEW INTERIOR BUILD OUT IS FOR A PRIMARY CARE CLINIC WITH WALL CONSTRUCTION, FINISHES, MECHANICAL, LIGHTING AND PLUMBING SYSTEMS. RENOVATION WORK INCLUDES INTERIOR RENOVATION AND REMOVAL OF EXISTING CLINICAL LAB, INTERIOR WALLS, PATCHING AND MATCHING FINISHES AND REMODEL OF EXISTING AREAS TO CREATE TOILET ROOMS AND CORRIDORS. THE OVERALL FACILITY IS EXISTING AND THE SMOKE ZONES SHALL REMAIN WITH MINIMAL MODIFICATION TO EXISTING SMOKE BARRIER LOCATION TO ACCOMMODATE NEW BOUNDARIES CREATED TO ACCOMMODATE THE NEW LAB SPACE. THE OVERALL BUILDING IS A HOSPITAL, CHAPTER 19 OF THE NFPA 101 LSC, THE AREA BEING RENOVATED IS A BUSINESS OCCUPANCY AND SHALL COMPLY WITH BOTH CHAPTER 19 AND 18 TO MAINTAIN THE INTEGRITY OF THE OVERALL BUILDING AND THE INTERIOR ELEMENTS SHALL COMPLY WITH CHAPTER 38 TO ACCOMMODATE THE OCCUPANCY TYPE OF THAT AREA.
CODE ANALYSIS
THE CONSTRUCTION TYPE IS DETERMINED BASED UPON THE ALLOWABLE AREA AND HEIGHT REQUIREMENTS OF CHAPTER 5 OF THE 2018 IBC. CONSTRUCTION TYPE AND MATERIALS SHALL BE PER CHAPTER 6 OF THE IBC FOR TYPE I-B, ASSUMED, CONSTRUCTION AS FOLLOWS: IS EXISTING AND NOT TO BE CHANGED.
1. OCCUPANCY TYPE: B-BUSINESS, IBC CHAPTER 3/LSC CHAPTER 38
2. CONSTRUCTION TYPE: I-B (IBC CHAPTER 5)
3. FIRE RESISTIVE RATINGS TYPE CONSTRUCTION, CHAPTER 6 IBC/NFPA 101:
STRUCTURAL FRAME: NONCOMBUSTIBLE, 2-HOUR FIRE RESISTIVE
BEARING WALLS
EXTERIOR: NONCOMBUSTIBLE, 2 -HOUR FIRE RESISTIVE
INTERIOR: NONCOMBUSTIBLE, 2-HOUR FIRE RESISTIVE
NON-BEARING WALLS AND PARTITIONS
EXTERIOR: NONCOMBUSTIBLE, VARIES PER TABLE 602-HOUR FIRE RESISTIVE
INTERIOR: NONCOMBUSTIBLE, 0-HOUR FIRE-RESISTIVE
FLOOR: NONCOMBUSTIBLE, 2-HOUR FIRE RESISTIVE
ROOF: NONCOMBUSTIBLE, 1-HOUR FIRE RESISTIVE
SHAFT ENCLOSURES 2-HOUR FIRE RESISTIVE >4 STORIES (IBC 713.4, LSC 12.3.6)
4. STRUCTURAL DESIGN SHALL COMPLY WITH CHAPTER 16 OF THE IBC.
5. ALLOWABLE HEIGHT: IS EXISTING AND NOT TO BE CHANGED. (IBC, TABLE 504.3)
6. ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLAN: IS EXISTING AND NOT TO BE CHANGED. (IBC, TABLE 504.4)
7. ALLOWABLE AREA: IS EXISTING AND NOT TO BE CHANGED. (IBC, TABLE 506.2)
8. BUILDING SEPARATION: IS EXISTING AND NOT TO BE CHANGED. (IBC, TABLE 602)
9. MEANS OF EGRESS
• CLEAR WIDTH OF CORRIDORS SHALL BE CLEAR 44 INCHES.
• CLEAR WIDTH OF DOORS SHALL BE CLEAR 32 INCHES
• NOT LESS THAN 2 EXITS SHALL BE PROVIDED PER FLOOR.
• ADDITION OCCUPANCY LOAD: <500 THEREFORE 2 EXITS REQUIRED (LSC 7.4.1)
• MAXIMUM TRAVEL DISTANCE, FULLY SPRINKLED: 300 FEET (LSC 38.2.6.3)
• COMMON PATH OF TRAVEL SHALL NOT EXCEED 100 FEET (LSC 38.2.5.3.1)
• DEAD END CORRIDORS SHALL NOT EXCEED 50 FEET. (LSC 38.2.5.2.1)
• MEANS OF EGRESS SHALL BE ILLUMINATED. (LSC 38.2.8)
• EMERGENCY LIGHTING SHALL BE PROVIDED, BUILDING OVER 3 STORIES. (LSC 38.2.9.1)
• EXIT SIGNAGE SHALL BE PROVIDED. (LSC 38.2.10)
10. PROTECTION FROM ANY AREA HAVING A DEGREE OF HAZARD GREATER THAN THAT NORMAL TO THE GENERAL OCCUPANCY OF THE BUILDING OR STRUCTURE SHALL BE PROVIDED BY PROTECTING THE AREA WITH AUTOMATIC EXTINGUISHING SYSTEMS IN ACCORDANCE WITH SECTION 9.7(3). WHERE HAZARD IS SEVER PER LSC CHAPTER 38, SOILED HOLDING, PROTECTION IS PROVIDED WITH AN AUTOMATIC EXTINGUISHING SYSTEMS THE SPACE SHALL ALSO BE ENCLOSED WITH
SMOKE PARTITIONS IN ACCORDANCE WITH SECTION 8.4.
• 1-HOUR FIRE RESISTANCE RATING AND AUTOMATIC SPRINKLER SYSTEM IS REQUIRED FOR THE FOLLOWING: SOILED HOLDING AND HIGH HAZARD
CONTENT AREAS PER LSC 38.2.2.
11. INTERIOR FINISH
• WALLS AND CEILINGS: INTERIOR FINISH FLAME SPREAD SHALL BE LIMITED PER CHAPTER 8 OF THE NFPA 101 TO CLASS A, B AND C MATERIALS. INTERIOR
WALL AND CEILING FINISH SHALL BE CLASS A OR CLASS B IN EXITS, CORRIDORS AND LOBBIES; AND CLASS A, CLASS B, OR CLASS C IN ALL OTHER AREAS.
(LSC 38.3.3)
• CLASS A: FLAME SPREAD 0-25; SMOKE DEVELOPED 0-450.
• CLASS B: FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450.
• CLASS C: FLAME SPREAD 76-200; SMOKE DEVELOPED 0-450
• FLOORS: INTERIOR FLOOR FINISH SHALL BE CLASS I OR CLASS II IN CORRIDORS AND EXITS.
• FABRIC DRAPERIES, CURTAINS (EXCLUDING SHOWER CURTAINS, BUT INCLUDING CUBICLE CURTAINS), AND OTHER LOOSELY HANGING FABRICS AND
FILMS SERVING AS FURNISHINGS OR DECORATIONS IN HEALTH CARE OCCUPANCIES MUST MEET THE FLAME RESISTANCE REQUIREMENTS OF NFPA 701, STANDARD METHODS OF FIRE TESTS FOR FLAME-RESISTANT TEXTILES AND FILMS.
• UPHOLSTERED FURNITURE AND MATTRESSES. UPHOLSTERED FURNITURE AND MATTRESSES MUST ALSO MEET SPECIFIED REQUIREMENTS, BASED ON
NFPA 260, NFPA 261, NFPA 266, 16 CRF 1632, ASTME E1537, AND ASTME E1590
12. EXTINGUISHMENTS REQUIREMENTS, PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED PER NFPA 10. (38.3.5)
13. DETECTION, ALARM, AND COMMUNICATIONS SYSTEMS.
• FIRE ALARM SYSTEM SHALL BE PROVIDED LSC, NFPA 70 (NEC) AND NFPA 72. (LSC 9.6.1)
• FIRE ALARM MAY BE BY MANUAL MEANS (LSC 38.4.2)(LSC 9.6.2)
• OCCUPANT NOTIFICATION SHALL BE THROUGH AUTOMATIC MEANS. (LSC 38.3.4.3)
• SMOKE DETECTION SHALL BE PROVIDED PER NFPA 72.
• EMERGENCY RESPONDER NOTIFICATION SHALL BE NOTIFIED BY ALARM AND DETECTION SYSTEM. (LSC 38.3.4.4)
14. FIRE SUPPRESSION:
SPRINKLER SYSTEM: BUILDING IS REQUIRED TO BE SPRINKLED THROUGHOUT IN ACCORDANCE WITH NFPA 13.
THE SPRINKLER SYSTEM SHALL BE HYDRAULICALLY DESIGNED IN ACCORDANCE WITH 2013 EDITION OF NFPA 13 AND THE SIXTH EDITION OF THE DEPARTMENT OF
VETERANS AFFAIRS FIRE PROTECTION DESIGN MANUAL: MINIMUM DESIGN REQUIREMENTS:
STORAGE MECHANICAL AND ELECTRICAL ROOMS SHALL BE PROTECTED AS:
ORDINARY HAZARD OCCUPANCY, GROUP 1: 0.15 GPM/FT2 OVER 1,500 FT2.
HOSE STREAM ALLOWANCE: 250 GPM
ALL OTHER AREAS SHALL BE PROTECTED AS:
LIGHT HAZARD OCCUPANCY: 0.10 GPM/FT2 OVER 1,500 FT2.
HOSE STREAM ALLOWANCE: 100 GPM
ALL SPRINKLERS WITHIN THE SMOKE ZONE SHALL BE QUICK RESPONSE SPRINKLERS.
15. CONSTRUCTION BARRIERS CONSTRUCTED ALONG MEANS OF EGRESS ALONG HEALTHCARE OCCUPANCIES (LSC CHAPTER 18 AND 19) SHALL BE CONSTRUCTED
AND MAINTAINED PER NFPA 241.
CODE ANALYSIS - NFPA 101
KEY PLAN
N
G
A
B
C
D
E
F
H
1 2 3 4 5 6 7 8 9 10 11
7074 SF
15472
A
PACT TOILET
CW183
STORAGE
CW160G
TELE-HEALTH
CW160B
TELE-RETINAL
CW160A
TEAM WORK AREA
CW160
TELE-HEALTH
CW160D
HYBRID EXAM
CW160E
SOILED
CW161
CLEAN
CW162
HYBRID EXAM
CW186
HYBRID EXAM
CW150S
HYBRID EXAM
CW150R
HYBRID EXAM
CW150Q
WOMEN EXAM
CW150P
WOMEN EXAM
CW150N
WOMEN'S TOILET
CW150OHYBRID EXAM
CW150M
HYBRID EXAM
CW150L
HYBRID EXAM
CW150K
HYBRID EXAM
CW150J
PROCEDURE
CW150H
PROCEDURE TOILET
CW150I
HYBRID EXAM
CW150G
HYBRID EXAM
CW150F
HYBRID EXAM
CW150E
HYBRID EXAM
CW150D
HYBRID EXAM
CW140Q
HYBRID EXAM
CW150C
HYBRID EXAM
CW150B
HYBRID EXAM
CW150A
NURSE MANAGER
CW152
HAC
CW171
PATIENT CORRIDOR
CWC9
PATIENT CORRIDOR
CWC4
WOMEN EXAM
CW140J
WOMEN TOILET
CW140I
WOMEN EXAM
CW140H
HYBRID EXAM
CW140G PACT TOILET
CW140U
HYBRID EXAM
CW140F
HYBRID EXAM
CW140E
HYBRID EXAM
CW140D
HYBRID EXAM
CW140C
HYBRID EXAM
CW140B
HYBRID EXAM
CW140A
HT / WT
CWC6-A
HYBRID EXAM
CW140T
HYBRID EXAM
CW140S
HYBRID EXAM
CW140R
HT / WT
CWC4-A
PACT TOILET
CW151
HYBRID EXAM
CW140P
HYBRID EXAM
CW140O
HYBRID EXAM
CW140N
HYBRID EXAM
CW140M
HYBRID EXAM
CW140L
HYBRID EXAM
CW140K
FAMILY TOILET
CW174
PATIENT CORRIDOR
CWC6
TEAM WORK AREA
CW140
TEAM WORK AREA
CW150
STAFF LOCKER
CW157
STAFF FEMALE
TOILET
CW158
STAFF MALE TOILET
CW159
PACT WORKROOM
CW142
PACT WORKROOM
CW143
CLEAN
CW144
STAFF FEMALE
TOILET
CW145
STAFF MALE TOILET
CW146
EQUIPMENT
CW147
SHAFT
SOILED
CW149
PACT WORKROOM
CW148
SHAFT
STAFF LOUNGE /
CONFERENCE /
TRAINING ROOM
CW155
STAIR NO. 3
STAFF CORRIDOR
CWC5
FAMILY TOILET
CW175
HT / WT
CWC9-A
FEMALE PUBLIC
TOILET
CW170B
MALE PUBLIC
TOILET
CW170A
STAIR NO. 1
MEDICATION
CW150T
MEDICATION
95-A
WHEELCHAIR
CWC1E
CHECK-IN KIOSK
CWC1FVOLUNTEER
CWC1D
RECEPTION
CW180
WAITING AREA
CW170
CORRIDOR
CWC1
19007 SF
100191
B
FEC
FEC
FEC
FEC
FECFEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
BUILDING
EXIT
SUITE EXIT
SUITE EXIT
SUITE
EXIT
SUITE
EXIT
SUITE
EXIT
SUITE EXIT
SUITE EXIT
TRAVEL DISTANCE: 211' - 8"
EXIT
E X
IT S
E
P A
R A
TIO
N
: 119' - 3"
DIAGONAL DISTANCE: 188' - 9"
ELECTRICAL
CW160F
HAC
CW187
MEDICATION
CW160-A
OFFICE MANAGER
CW153
CHIEF MEDICAL
OFFICER
CW154
SHARED MEDICAL
APPT
CW185
SHARED MEDICAL
APPT
CW184
STORAGE
CW184A
STORAGE
CW185A
PACT TOILET
CW186
DATA
CW169
ENTRANCE
VESTIBULE
CWC1A
TOILET VESTIBULE
CWC15A
CORRIDOR
CWC14
CORRIDOR
CWC13
ELECTRICAL
CW160C
TRAVEL DISTANCE: 174' - 3"
N
STAFF LOUNGE /
CONFERENCE /
TRAINING ROOM
CW155
WAITING AREA
CW170
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
N O T F
N
STR
U C
TIO
N o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
Building Number
C U s e rs \l s p lic h a l\ D o c u m e n ts \1
.1
V
A M e m p h is
B ld g
P ri m a ry
C a re ls p lic h a l.
rv t
/1 /2
:1
:2
P M
GI101
LIFE SAFETY PLAN
GUIDON DESIGN, INC
1221 N PENNSYLVANIA STEET, SUITE 200
INDIANAPOLIS, IN 46202
317.800.6388
ANDREW SCHAEWE
CMTA CONSULTING ENGINEERS, INC
10411 MEETING STREET
PROSPECT, KY 40059
502.326.3085
ANDREW MYERS
RENOVATE BUILDING 1 PRIMARY
CARE
MEMPHIS VAMC
614-17-113
RYAN STEPHENS,
COR MEMPHIS, TN
05/01/2019 AWS JP
BID SET
FULLY SPRINKLERED
LIFE SAFETY OCCUPANCY COUNT
AREA SF OCC OCC FACTOR # OF OCC
FIRST FLOOR
WAITING AREA 7074 SF A 15 472
PRIMARY CARE 19007 SF B 100 191
PRIMARY CARE TOTAL: 26081 SF 663
SCALE: 3/32" = 1'-0"GI101
1 FIRST FLOOR - LIFE SAFETY PLAN
OCCUPANCY LOAD: 663 X .2 = 133 INCHES TOTAL
EXISTING DOOR WIDTH: 160 INCHES TOTAL
INFECTION CONTROL PROJECT INFORMATION
CONSTRUCTION ACTIVITY - FIRE RISK: TYPE C
PATIENT RISK GROUP: MEDIUM
CLASS OF PRECAUTION MATRIX: III
REFER TO LIST OF REQUIRED INFECTION CONTROL PRECAUTIONS OUTLINED
BY CLASS IN SPECIFICATION 010110 AND ADDITIONAL INFORMATION.
REFER TO DRAWINGS, SPECIFICATIONS AND DOOR HARDWARE SCHEDULE
FOR ADDITIONAL INFORMATION.
PROJECT SHALL BE COMPLETED IN TWO PHASES WITH PHASE ONE BEING
COMPLETED PRIOR TO PHASE TWO.
COORDINATE FULL SCOPE OF WORK WITH ENGINEERING DRAWINGS AND
FIELD VERIFICATION. CONTRACTOR IS RESPONSIBLE FOR SCOPE OF ABOVE
CEILING WORK REQUIRED ABOVE AND BELOW THE FLOOR PLATE OF THE
PROJECT BOUNDARY.
COORDINATE LOCATION OF TEMPORARY INFECTION CONTROL (IC) BARRIER
WALL CONSTRUCTION AND INFECTION CONTROL (IC) MEASURES WITH COR
AND PATIENT SAFETY/ INFECTION CONTROL REPRESENTATIVE. TEMPORARY
IC BARRIER WALL CONSTRUCTION LOCATIONS IN DRAWINGS ARE
APPROXIMATE. CONTRACTOR SHALL PROVIDE DRAWING TO COR AND
PATIENT SAFETY/ INFECTION CONTROL REPRESENTATIVE ONCE ICRA
PROTOCOLS AND PLAN IS APPROVED.
SCHEDULE AND TIME OF CONSTRUCTION WORK TO BE APPROVED BY COR
AND NURSING STAFF BEFORE CONSTRUCTION MAY BEGIN. PROVIDE PHASING
INFORMATION FOR ABOVE CEILING WORK IN THE CONTRACTOR PROVIDED
CMP SCHEDULE FOR WORK ALSO REQUIRED ABOVE AND BELOW THE FLOOR
PLATE OF THE PROJECT BOUNDARY.
ABOVE CEILING WORK SHALL TAKE PLACE BETWEEN THE HOURS OF 5:00 PM
AND 5:00 AM. IN AREAS THAT REQUIRE ABOVE CEILING WORK WHERE
CEILINGS ARE TO REMAIN, CEILING TILES SHALL BE REMOVED AND STORED IN
A SAFE MANOR UNTIL CEILING TILES CAN BE REINSTALLED. DAMAGED AND
BROKEN CEILING TILES SHALL BE REPLACED BY CONTRACTOR.
EXIT/ACCESS FOR ADJACENT OPERATIONAL AREAS SHALL BE MAINTAINED
DURING NORMAL BUSINESS HOURS. SEE SPECIFICATION FOR HOURS OF
OPERATION.
WORK REQUIRING VIBRATION OR LOAD NOISE SHALL TAKE PLACE BETWEEN
THE HOURS OF 5:00 PM AND 5:00 AM. EVERY EFFORT SHALL BE MADE TO
KEEP NOISE AND VIBRATION TO A MINIMUM.
PROVIDE THE FOLLOWING INFECTION CONTROL MEASURES, A 24"X36" STICKY
WALK OFF MAT AND HAND SANITIZER AT EACH TEMPORARY DOOR LOCATION.
MAT SHALL BE REPLACED OR CLEANED AS NECESSARY
PROVIDE THE VA AND OSHA REQUIRED TEMPORARY SIGNAGE AT EACH
TEMPORARY DOOR LOCATION.
CONTRACTOR SHALL SUPPLY SPILL KIT. SPILL KIT TO INCLUDE SHOP VAC,
MULTI-PURPOSE SPILL CONTROL SORBENTS TO ABSORB NON AGGRESSIVE
LIQUIDS UP TO 30 GALLONS.
ALL NEW MATERIAL MOVED THROUGH THE FACILITY SHALL BE COVERED WITH
4 MIL. POLY SHEET.
ALL DEMOLITION MATERIAL SHALL BE REMOVED FROM THE PROJECT
BOUNDARY THROUGH THE FACILITY TO DUMPSTER ALONG VA APPROVED
ROUTE IN ENCLOSED DUMPSTER CART DESIGNED FOR SUCH PURPOSED
WITH A LID.
ALL MATERIAL, DEBRIS AND HAZARDOUS MATERIALS SHALL BE PROPERLY
STORED IN DESIGNATED AREAS AND APPROVED CONTAINERS. FLAMMABLE
MATERIALS SHALL NOT BE STORED IN THE FACILITY.
PROVIDE CONTAINMENT CART FOR ABOVE CEILING ACCESS OUTSIDE
PROJECT BOUNDARY.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
INFECTION CONTROL GENERAL NOTES
PHASING GENERAL NOTES
A
B
C
PROJECT AREAS TO BE OCCUPIED BY STAFF AND VETERANS THROUGHOUT
CONSTRUCTION.
PROJECT SHALL BE COMPLETED REGULAR BUSINESS HOURS, 6:00 AM TO 6:00
PM. COORDINATE WITH COR. ALL WORK TO BE COMPLETED AND OPEN FOR
PUBLIC USE AT THE END OF EACH NIGHT'S WORK.
REFER TO SPECIFICATION 01 00 00 FOR INFORMATION ON WORK DURATION
FOR EACH PHASE AND AREA OF WORK.
INFECTION CONTROL PLAN NOTES #
PROVIDE TEMPORARY 1 HR FIRE RATED SMOKE BARRIER WALL
CONSTRUCTION PER NFPA 241. REFER TO DETAIL 1/GI102.
PROVIDE TEMPORARY INFECTION CONTROL CONSTRUCTION DOOR. REFER
TO ELEVATION 3/GI102.
PROVIDE TEMPORARY INFECTION CONTROL BARRIER WALL CONSTRUCTION.
REFER TO DETAIL 2/GI102.
IC/PHASING LEGEND
TEMPORARY WALLS. SEE PLAN AND
PLAN NOTES
TEMPORARY CONSTRUCTION ACCESS
DOORS
REFERENCE AREA FOR ABOVE
CEILING WORK ON FLOOR BELOW.
REFER TO ENGINEERING DRAWINGS
FOR FULL SCOPE OF WORK
BEYOND PROJECT BOUNDARY
PROJECT BOUNDARY
PHASE 2 OF 2
PHASE 1 OF 2
TEMPORARY IC BARRIER WALL
CONSTRUCTION (DUST WALL)
5/8" TYPE X GYP BD
3 5/8" STEEL STUDS @ 16"
O.C.
BEAD OF CONT. SEALANT
6-MIL FIRE RETARDENT POLY
INTERIOR SIDE
CEILING, RE: RCP SHEETS
2" DEEP LEG 3 5/8" STEEL SLIP TRACK
3 5/8" STEEL STUD TRACK
4" M
IN
CONTINUOUSLY ADHERE 6-MIL. FIRE
RETARDANT POLY TO DECK WITH TAPE
CONTINUOUSLY ADHERE FIRE RETARDENT
POLY TO FLOOR WITH TAPE
EXISTING DECK
CONSTRUCTION
SIDE
OCCUPIED
SIDE
PUBLIC
SIDE
1 HOUR FIRE RATED DOOR ASSEMBLY, FRAME
WITH SEALS AND HARDWARE
TRIATEK MONITOR OR EQUIVALENT
HAND SANITIZER
SEAL ALL EDGES WITH TAPE
SEAL ALL EDGES WITH TAPE
REFER TO TEMPORARY BARRIER TYPE
FOR REQUIRED CONDITION TO
STRUCTURE ABOVE
VA / OSHA TEMPORARY SIGNAGE
CONTINUOUS FIRESAFE SEALANT
TOP AND BOTTOM, & BOTH SIDES
3 1/2" SOUND ATTENUATION
BATT.
5/8" TYPE X GYPSUM BOARD, BOTH
SIDES
3 5/8" METAL STUD @ 16" O.C.
WITH RUNNER CHANNELS ALONG
TOP AND BOTTOM
CONSTRUCTION
SIDE
PUBLIC
SIDE
6 MIL. FIRE RETARDANT VISQUEEN
MEMBRANE. CONTINUOUSLY
ADHERE TO THE STRUCTURAL DECK
ABOVE AND TO THE FLOOR BELOW
WITH TAPE.
UNDERSIDE OF STRUCTURAL DECK
UL LISTING:
U465
COORDINATE WITH EXISTING
CEILING
KEY PLAN
N
G
A
B
C
D
E
F
H
1 2 3 4 5 6 7 8 9 10 11
C
LE
A R
6'
CLEAR
6' - 0"
CLEAR
6' - 0"
C
LE
A R
6'
C
LE
A R
6'
PHASE 1
PHASE 1 PHASE 2
PACT TOILET
CW183
STORAGE
CW160G
TELE-HEALTH
CW160B
TELE-RETINAL
CW160A
TEAM WORK AREA
CW160
TELE-HEALTH
CW160D
HYBRID EXAM
CW160E
SOILED
CW161
CLEAN
CW162
HYBRID EXAM
CW186
HYBRID EXAM
CW150S
HYBRID EXAM
CW150RHYBRID EXAM
CW150Q
WOMEN EXAM
CW150P
WOMEN EXAM
CW150N
WOMEN'S TOILET
CW150O
HYBRID EXAM
CW150M
HYBRID EXAM
CW150L
HYBRID EXAM
CW150K
HYBRID EXAM
CW150J
PROCEDURE
CW150H
PROCEDURE TOILET
CW150I
HYBRID EXAM
CW150G
HYBRID EXAM
CW150F
HYBRID EXAM
CW150E
HYBRID EXAM
CW150D
HYBRID EXAM
CW140Q
HYBRID EXAM
CW150C
HYBRID EXAM
CW150B
HYBRID EXAM
CW150A
NURSE MANAGER
CW152
HAC
CW171
PATIENT CORRIDOR
CWC9
PATIENT CORRIDOR
CWC4
WOMEN EXAM
CW140J
WOMEN TOILET
CW140I
WOMEN EXAM
CW140H
HYBRID EXAM
CW140G PACT TOILET
CW140U
HYBRID EXAM
CW140F
HYBRID EXAM
CW140E
HYBRID EXAM
CW140D
HYBRID EXAM
CW140C
HYBRID EXAM
CW140B
HYBRID EXAM
CW140A
HT / WT
CWC6-A
HYBRID EXAM
CW140T
HYBRID EXAM
CW140S
HYBRID EXAM
CW140R
HT / WT
CWC4-A
PACT TOILET
CW151
HYBRID EXAM
CW140P
HYBRID EXAM
CW140O
HYBRID EXAM
CW140N
HYBRID EXAM
CW140M
HYBRID EXAM
CW140L
HYBRID EXAM
CW140K
FAMILY TOILET
CW174
PATIENT CORRIDOR
CWC6
TEAM WORK AREA
CW140
TEAM WORK AREA
CW150
STAFF LOCKER
CW157
STAFF FEMALE
TOILET
CW158
STAFF MALE TOILET
CW159
PACT WORKROOM
CW142
PACT WORKROOM
CW143
CLEAN
CW144
STAFF FEMALE
TOILET
CW145
STAFF MALE TOILET
CW146
EQUIPMENT
CW147
SHAFT
SOILED
CW149
PACT WORKROOM
CW148
SHAFT
STAFF LOUNGE /
CONFERENCE /
TRAINING ROOM
CW155
STAIR NO. 3
STAFF CORRIDOR
CWC5
FAMILY TOILET
CW175
HT / WT
CWC9-A
FEMALE PUBLIC
TOILET
CW170B
MALE PUBLIC
TOILET
CW170A
STAIR NO. 1
MEDICATION
CW150T
MEDICATION
95-A
WHEELCHAIR
CWC1E
C H
E C
K -I
N K
IO
S
K
C W
C F
VOLUNTEER
CWC1D
RECEPTION
CW180
WAITING AREA
CW170
CORRIDOR
CWC1
MEDICATION
CW160-A
HAC
CW187
OFFICE MANAGER
CW153
CHIEF MEDICAL
OFFICER
CW154
SHARED MEDICAL
APPT
CW185
SHARED MEDICAL
APPT
CW184
STORAGE
CW184A
STORAGE
CW185A
PACT TOILET
CW186
DATA
CW169
ENTRANCE
VESTIBULE
CWC1A
TOILET VESTIBULE
CWC15A
CORRIDOR
CWC14
CORRIDOR
CWC13
C
LE
A R
6'
CLE
AR6'
- 0
N
ELECTRICAL
CW160F
ELECTRICAL
CW160C
WAITING AREA
CW170
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
N O T F
N
STR
U C
TIO
N o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
Building Number
C U s e rs \l s p lic h a l\ D o c u m e n ts \1
.1
V
A M e m p h is
B ld g
P ri m a ry
C a re ls p lic h a l.
rv t
/1 /2
:1
:2
P M
GI102
INFECTION CONTROL/PHASING
PLANGUIDON DESIGN, INC
1221 N PENNSYLVANIA STEET, SUITE 200
INDIANAPOLIS, IN 46202
317.800.6388
ANDREW SCHAEWE
CMTA CONSULTING ENGINEERS, INC
10411 MEETING STREET
PROSPECT, KY 40059
502.326.3085
ANDREW MYERS
RENOVATE BUILDING 1 PRIMARY
CARE
MEMPHIS VAMC
614-17-113
RYAN STEPHENS,
COR MEMPHIS, TN
05/01/2019 AWS JP
BID SET
FULLY SPRINKLERED
SCALE: 1 1/2" = 1'-0"GI102
2 TEMPORARY INFECTION CONTROL BARRIER WALL CONSTRUCTION
SCALE: 1/4" = 1'-0"GI102
3 TEMPORARY WALL CONSTRUCTION ELEVATION
SCALE: 1 1/2" = 1'-0"GI102
1 TEMPORARY 1 HR FIRE RATED SMOKE BARRIER WALL CONSTRUCTION NFPA 241
SCALE: 3/32" = 1'-0"GI102
4 FIRST FLOOR - INFECTION CONTROL / PHASING PLAN
STATEMENT OF BID ITEMS
ALTERNATE A - DEDUCT TERRAZO FLOORING
REMOVE ALL TERRAZO FLOORING AS INDICATED AND REPLACED BY LVT TO
BE SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR. AREA INCLUDE
BUT ARE NOT LIMITED TO ENTRANCE CORRIDOR. REFER TO AF102 FOR THE
EXTENT OF FLOOR COVERAGE & DESIGN.
ALTERNATE B - DEDUCT SYSTEMS FURNITURE
REMOVE ALL SYSTEMS FURNITURE INDICATED TO BE SUPPLIED AND
INSTALLED BY THE GENERAL CONTRACTOR. AREA INCLUDE BUT ARE NOT
LIMITED TO PATIENT EXAM ROOMS, TEAM WORK AREAS, PACT WORKROOMS,
SHARED MEDICAL APPT ROOMS AND TELE HEALTH ROOMS.
ALTERNATE C - DEDUCT MAIN ENTRANCE VESTIBULE
REMOVE ALL WORK AT THE MAIN ENTRANCE VESTIBULE INDICATED TO BE
SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR WITH THE
EXCEPTION OF ALL WORK ASSOCIATED WITH PLAN NOTE 8 ON AD101 & PLAN
NOTE 6 ON AS101.
ALTERNATE D - DEDUCT SLIDING DOOR (STAFF SIDE)
REMOVE APPROXIMATELY 42 SLIDING DOORS, FROM THE TEAM WORK AREA
SIDE OF ALL MEDICAL EXAM AND TELE HEALTH ROOMS AND REPLACE WITH
STANDARD SWINGING 36" DOORS.
ALTERNATE E - DEDUCT SLIDING DOOR (PATIENT SIDE)
REMOVE APPROXIMATELY 39 SLIDING DOORS, FROM THE PAITENT CORRIDOR
SIDE OF ALL MEDICAL EXAM, PRODECURE AND TELE HEALTH ROOMS AND
REPLACE WITH STANDARD SWINGING 42" DOORS.
A
B
C
D
E
BID ITEM #1: BASE BID.
BID ITEM #2: ALL WORK AS DESCRIBED FOR BID ITEM #1 ABOVE MINUS THAT
PORTION OF WORK SHOWN AS ALTERNATE A.
KEY PLAN
N
G
A
B
C
D
E
F
H
1 2 3 4 5 6 7 8 9 10 11
PACT TOILET
CW183
STORAGE
CW160G
TELE-HEALTH
CW160B
TELE-RETINAL
CW160A
TEAM WORK AREA
CW160
TELE-HEALTH
CW160D
HYBRID EXAM
CW160E
SOILED
CW161
CLEAN
CW162
HYBRID EXAM
CW186
HYBRID EXAM
CW150S
HYBRID EXAM
CW150R
HYBRID EXAM
CW150Q
WOMEN EXAM
CW150P
WOMEN EXAM
CW150N
WOMEN'S TOILET
CW150O
HYBRID EXAM
CW150M
HYBRID EXAM
CW150L
HYBRID EXAM
CW150K
HYBRID EXAM
CW150J
PROCEDURE
CW150H
PROCEDURE TOILET
CW150I
HYBRID EXAM
CW150G
HYBRID EXAM
CW150F
HYBRID EXAM
CW150E
HYBRID EXAM
CW150D
HYBRID EXAM
CW140Q
HYBRID EXAM
CW150C
HYBRID EXAM
CW150B
HYBRID EXAM
CW150A
HAC
CW171
PATIENT CORRIDOR
CWC9
PATIENT CORRIDOR
CWC4
WOMEN EXAM
CW140J
WOMEN TOILET
CW140I
WOMEN EXAM
CW140H
HYBRID EXAM
CW140G
PACT TOILET
CW140U HYBRID EXAM
CW140F
HYBRID EXAM
CW140E
HYBRID EXAM
CW140D
HYBRID EXAM
CW140C
HYBRID EXAM
CW140B
HYBRID EXAM
CW140A
HT / WT
CWC6-A
HYBRID EXAM
CW140T
HYBRID EXAM
CW140S
HYBRID EXAM
CW140R
HT / WT
CWC4-A
PACT TOILET
CW151
HYBRID EXAM
CW140P
HYBRID EXAM
CW140O
HYBRID EXAM
CW140N
HYBRID EXAM
CW140M
HYBRID EXAM
CW140L
HYBRID EXAM
CW140K
FAMILY TOILET
CW174
PATIENT CORRIDOR
CWC6
TEAM WORK AREA
CW140
TEAM WORK AREA
CW150
STAFF LOCKER
CW157
STAFF FEMALE
TOILET
CW158
STAFF MALE TOILET
CW159
PACT WORKROOM
CW142
PACT WORKROOM
CW143
CLEAN
CW144
STAFF FEMALE
TOILET
CW145
STAFF MALE TOILET
CW146
EQUIPMENT
CW147
SHAFT
SOILED
CW149
PACT WORKROOM
CW148
SHAFT
STAFF LOUNGE /
CONFERENCE /
TRAINING ROOM
CW155
STAIR NO. 3
STAFF CORRIDOR
CWC5
FAMILY TOILET
CW175
HT / WT
CWC9-A
HAC
CW187
FEMALE PUBLIC
TOILET
CW170B
MALE PUBLIC
TOILET
CW170A
STAIR NO. 1
MEDICATION
CW150T
MEDICATION
95-A
WHEELCHAIR
CWC1E
CHECK-IN KIOSK
CWC1F
VOLUNTEER
CWC1D
RECEPTION
CW180
WAITING AREA
CW170
CORRIDOR
CWC1
MEDICATION
CW160-A
OFFICE MANAGER
CW153
NURSE MANAGER
CW152
CHIEF MEDICAL
OFFICER
CW154
SHARED MEDICAL
APPT
CW185
SHARED MEDICAL
APPT
CW184
STORAGE
CW184A
STORAGE
CW185A
PACT TOILET
CW186
DATA
CW169
ENTRANCE
VESTIBULE
CWC1A
TOILET VESTIBULE
CWC15A
BBBB
B
B
B
B
A
C
BB
B
B
B
ELECTRICAL
CW160C
ELECTRICAL
CW160F
N
WAITING AREA
CW170
B
B
B
B
B
B
B
CW140BA
CW140BB
HYBRID EXAM
CW140B
PATIENT CORRIDOR
CWC6
TEAM WORK AREA
CW140
E
D
B
B
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
N O T F
N
STR
U C
TIO
N o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
Building Number
C U s e rs \l s p lic h a l\ D o c u m e n ts \1
.1
V
A M e m p h is
B ld g
P ri m a ry
C a re ls p lic h a l.
rv t
/1 /2
:1
:4
P M
GI103
BID ALTERNATES
GUIDON DESIGN, INC
1221 N PENNSYLVANIA STEET, SUITE 200
INDIANAPOLIS, IN 46202
317.800.6388
ANDREW SCHAEWE
CMTA CONSULTING ENGINEERS, INC
10411 MEETING STREET
PROSPECT, KY 40059
502.326.3085
ANDREW MYERS
RENOVATE BUILDING 1 PRIMARY
CARE
MEMPHIS VAMC
614-17-113
RYAN STEPHENS,
COR MEMPHIS, TN
05/01/2019 AWS JP
BID SET
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"GI103
1 FIRST FLOOR - BID ALTERNATE PLAN
SCALE: 3/8" = 1'-0"GI103
2 ENLARGED PLAN @ TYPICAL HYBRID EXAM - BID ALTERNATE
CW132
CW133
CW134CW135
CW128
CW127ACW127
CW124
CW126C
CW126E
CW114
CW173
CW166A
CW170
CW166
CW120B
CW119
P-7P-6
CW110
NO 2
CW123
CW111A
CW105
CW120
CW120A
CW166B
CW113
CW165
CW171
CW172
CW126A
126D
CW127B
CW126
CW125 CW123B CW123A
CW139
CW138CW137CW136
CW104A
CW102BCW101B
NO 1
NO 3
CW175CW176CW177
CW178
CW179
CW180
CW140
CW140B
CW140A
CW140
CW141CW142
CW143
CW144
CW145CW146CW147
CW148
CW150
CW149
CW152C
CW152BCW152A
CW152E
CW152
CW151
CW149B
CW149A
CW149E
CW149C
CW183
CW191
CW191A
CW187
CW186CW185 CW185A
CW185B
CW190
CW189
CW184
CW182
CW181
CW174
CW196
CW196A
CW195
CW160A
CW160C
CW160D
CW160B
CW154
CW160
CW163
CW164
CW197
CW194B
CW194
CW192
CW194B CW194C
CW193
CW140D
CW140C
CW194A
FECELEVATOR
ELEVATOR
ELEVATOR
ELEVATOR
IMMUNOLOGY
LOBBY
TOILET
PTSD OFFICE
PTSD OFFICE
PTSD RESIDENTIAL
OFFICE
AGENT
CASHIER
ELIGIBILITY /
TRAVEL OFFICE
ELIGIBILITY /
TRAVEL OFFICE
PATIENT
ADVOCATE OFFICE
OFFICE
TELE OPERATOR
TESTINGTESTING
E C
OFFICE
MENS
TOILET
EXAM
ELEVATORELEVATOR
T CE C
ELEVATORELEVATOR
STAIR
YELLOW
WAITING
LOW VISION EXAM
EXAM
EYE CLINIC WAITING
EXAM
STORAGE
HAC
WOMENS TOILET
ELIGIBILITY OFFICE
TELECOM STORAGE HEAD CLERK
HEALTH
BENEFIT
SECTION OFFICE
ELIGIBILITY /
TRAVEL OFFICE
PATIENT
ADVOCATE OFFICE
PATIENT
ADVOCATE
OFFICE
SOCIAL
WORKER ADMIN
OFFICE
PTSD OFFICEPTSD OFFICE
EXAMPTSD OFFICEPTSD OFFICE
CORRIDOR
OFFICE
OPTOMETRY OFFICE
TOILET
ULTRASOUND-3
READINGREADING RM
CORRIDOR
STORAGE
CLINICAL
PHARMACY
EDUCATIONAL
CO-ORDINATOR
OPTOMETRY OFFICE
TC
TC
ELECTRICAL
STAIR
ELEVATORELEVATOR
STORAGE
CASE LAB
HEMATOLOGY
CASE LAB
CHEMISTRY SUPV
WOMENS TOILET
CARE LABANCILLARY TESTING OFFICE
FILES
STORAGE RM
NIGHT SUPVSUPV
TELECOM
SHAFT
SPECIAL
CARE LAB
CARE/PED
TECH OFFICE
HAC
SHAFT
SUPPLYOFFICEOFFICEMICROSCOPIC TEACHINGRESIDENTS
FROZEN
SECTION
CLOSET
BREAK RM
EXAM
ELEVATOR
WAITING
ACCESSION AREA
TOILET TOILET
BLOOD DWG
STORAGE
STORAGERECEPTION OFFICE
COPY
PGM
ASST
ADMINISTRATIVE CLERKS-4
SECYCHIEF
OFFICE-1PATHOLOGY OFFICE-2OFFICE-3OFFICE-4OFFICE-5
OFFICE
ELECTRICAL
FILE
B-V CODE
EXPANSION
CO-ORDINATOR
BREAK RM
MENS TOILET
BLOOD BANK
TB
REFMYC
OFFICE
MICROBIOLOGY
STAIR
AUTOCLAVE
FLOW
CYTOMETER
OFFICE
PCR RM
CONFERENCE
RECEPTION
MICROSCOPE RM
CASE LAB
HAZARDOUS MATERIAL REMOVAL LEGEND
PROJECT BOUNDARY
BEYOND PROJECT BOUNDARY
HAZARDOUS MATERIAL REMOVAL GENERAL NOTES
HAZMAT REMOVAL NOTES APPLY TO ENTIRE ROOMS. CONTRACTOR SHALL
IDENTIFY ALL MATERIALS DESCRIBED BY NOTE IN EACH ROOM AND REMOVE
ACCORDING TO SAFETY STANDARDS. REFERENCE SPECIFICATION 02 41 00
DEMOLITION & 02 82 11 TRADITIONAL ASBESTOS ABATEMENT AND
ATTACHMENTS FOR ADDITIONAL INFORMATION.
ALL HAZARDOUS MATERIALS SHALL BE REMOVED IN COMPLIANCE WITH
APPLICABLE CODES AND LAWS.
THE CONTRACTOR IS RESPONSIBLE TO VERIFY THE HAZARD(S) AND LEVEL OF
PROTECTION REQUIRED FOR ALL EMPLOYEES OR SUBCONTRACTORS TO
COMPLETE THE CONSTRUCTION WORK.
PROVIDE ABATEMENT OF VCT AND FLOORING MASTIC WITHIN HATCHED AREA.
BASED ON THE DATE OF THE EXISTING CONSTRUCTION IT IS ASSUMED LEAD
PAINT IS WITHIN THE PROJECT AREA. CONDUCT DEMOLITION OF THE
EXISTING SPACE WITH THE ASSUMPTION OF LEAD PAINT ON EXPOSED
PLASTER WALLS AND PAINTED SURFACES. REFER TO SPECIFICATION
SECTION 02 83 33.13 LEAD-BASED PAINT REMOVAL, DISPOSAL AND FOR
ADDITIONAL INFORMATION.
BASED ON THE DATE OF THE EXISTING CONSTRUCTION AND UNDERSTANDING
OF THE FACILITY, IT IS POSSIBLE THAT THERE IS LEAD PAINT WITHIN THE
PROJECT AREA. ON AREAS OF EXISTING CONSTRUCTION THAT CONTAIN
LEAD PAINT, DO NOT PROVIDE LEAD ABATEMENT. PROVIDE LEAD PAINT
SURFACE STABILIZATION ON EXISTING TO REMAIN WORK IS DONE.
CONTRACTOR TO USE MEASURES FOR PROTECTION AND TO MINIMIZE PAINT
DEBRIS.
CONTRACTOR TO SUBMIT LEAD SURFACES STABILIZATION PLAN AND
PROCEDURES PRIOR TO COMMENCING WORK. SUBMITTAL SHALL BE IN
ACCORDANCE WITH SPECIFICATIONS.
A
B
C
D
E
F
G
HAZARDOUS MATERIAL REMOVAL PLAN NOTES #
1 THE CONTRACTOR SHALL REMOVE ALL ASBESTOS CONTAINING BLACK MASTIC
AND 12" NON-ASBESTOS FLOOR TILE WITHIN THE PROJECT BOUNDARY,
UNLESS OTHERWISE NOTED.
KEY PLAN
N
* * NOTE * *
PER ASBESTOS SAMPLING REPORT BY
CASTLE HILLL ASSOCIATES, DATED
NOVEMBER 11, 2017.
BLACK RESIDUAL MASTIC ASBESTOS
CONTAINING MATERIAL FOUND UNDER
YELLOW MASTIC FOR NON-ASBESTOS 12"
FLOOR TILE THROUGHOUT RENOVATION
AREA FOOTPRINT EXCEPT IN RESTROOMS.
G
A
B
C
D
E
F
H
1 2 3 4 5 6 7 8 9 10 11
N
ENTRANCE
VESTIBULE
CWC1A
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
N O T F
N S
TR
U C
TIO
N o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
B
A
C
D
E
F
Building Number
C U s e rs \l s p lic h a l\ D o c u m e n ts \1
.1
V
A M e m p h is
B ld g
P ri m a ry
C a re ls p lic h a l.
rv t
/1 /2
:1
:4
P M
HA101
HAZARDOUS MATERIAL REMOVAL
PLANGUIDON DESIGN, INC
1221 N PENNSYLVANIA STEET, SUITE 200
INDIANAPOLIS, IN 46202
317.800.6388
ANDREW SCHAEWE
CMTA CONSULTING ENGINEERS, INC
10411 MEETING STREET
PROSPECT, KY 40059
502.326.3085
ANDREW MYERS
RENOVATE BUILDING 1 PRIMARY
CARE
MEMPHIS VAMC
614-17-113
RYAN STEPHENS,
COR MEMPHIS, TN
05/01/2019 AWS JP
BID SET
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"HA101
1 FIRST FLOOR - HAZARDOUS MATERIAL PLAN
| Sheets |
| GI000 - COVER SHEET |
File details come from the government source that posted it. Updated .