This document provides design drawings and room-by-room listings of asbestos and hazardous materials to be abated as part of a clinical laboratory renovation project at the Memphis VA Medical Center. The project involves general hospital construction including plumbing, mechanical, electrical and exterior work with an estimated value between $5-10 million. The solicitation seeks an experienced healthcare construction contractor to complete the project in accordance with specifications and drawings while considering infection control and environmental standards for work in a medical setting. Only Service-Disabled Veteran Owned Small Businesses listed in the CVE database and SAM will be considered, with the requirement being 100% set aside under the authority of 38 U.S.C 8127 (d). Questions must be submitted in writing by the anticipated solicitation release date of November 6, 2019 for the project taking place under Solicitation Number 36C24920R0008.

36C24920R0008 0008 Memphis VAMC 614-17-112 Clinical Lab Project - Asbestos HazMat Abatement Drawing Markups.pdf

View the file

Other files

File Type Posted
36C24920R0008-0009005.docx DOCX document
36C24920R0008-0008000.docx DOCX document
36C24920R0008-0008003.pdf PDF
36C24920R0008-0008001.pdf PDF
36C24920R0008-0007000.docx DOCX document
36C24920R0008-0006004.pdf PDF
36C24920R0008-0006007.pdf PDF
36C24920R0008-0006005.pdf PDF
36C24920R0008-0006011.pdf PDF
36C24920R0008-0006006.pdf PDF
36C24920R0008-0006001.pdf PDF
36C24920R0008-0006000.docx DOCX document
36C24920R0008-0006010.pdf PDF
36C24920R0008-0006012.pdf PDF
36C24920R0008-0006008.pdf PDF
36C24920R0008-0006002.pdf PDF
36C24920R0008-0006009.pdf PDF
36C24920R0008-0006003.pdf PDF
36C24920R0008-0005000.docx DOCX document
36C24920R0008-0004000.docx DOCX document
36C24920R0008-0004001.pdf PDF
36C24920R0008-0004002.pdf PDF
36C24920R0008-0003000.docx DOCX document
36C24920R0008-0003001.pdf PDF
36C24920R0008-0002006.pdf PDF
36C24920R0008-0002005.pdf PDF
36C24920R0008-0002008.pdf PDF
36C24920R0008-0002001.txt TXT text file
36C24920R0008-0002004.pdf PDF
36C24920R0008-0002003.pdf PDF
36C24920R0008-0002000.docx DOCX document
36C24920R0008-0002007.pdf PDF
36C24920R0008-0002002.pdf PDF
36C24920R0008-0001000.docx DOCX document
36C24920R0008-011.pdf PDF
36C24920R0008-007.pdf PDF
36C24920R0008-003.pdf PDF
36C24920R0008-004.pdf PDF
36C24920R0008-010.xlsx XLSX spreadsheet
36C24920R0008-009.xlsx XLSX spreadsheet
36C24920R0008-005.pdf PDF
36C24920R0008-006.pdf PDF
36C24920R0008-012.pdf PDF
36C24920R0008-001.docx DOCX document
36C24920R0008-008.pdf PDF
36C24920R0008-002.pdf PDF
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS/HAZMAT ABATEMENT PROJECT DESIGN DRAWING MARKUPS

MEMPHIS VAMC – MEMPHIS, TN

RENOVATE BUILDING 1 - CLINICAL LAB PROJECT

PROJECT 616-17-112

ASBESTOS AND HAZMAT ABATMENT DRAWING LEGEND

LEGEND

LETTER

ASBESTOS & HAZMAT

MATERIALS

LOCATIONS QUANTITY

A

Black residual mastic under yellow mastic on non-asbestos 12” floor tile

Throughout renovation area footprint except restrooms

25,722 sf

B

9” Gray floor tile CE120, CE122, CE125, CE126, CE133, CE134, CE135, CE137, CE139, CE144, CE145, CE147

2,208 sf

C

Black mastic under 9” floor tile

CE120, CE122, CE125,

CE126, CE133, CE134,

CE135, CE137, CE139,

CE144, CE145, CE147,

CE155

2,028 sf

D 12” green & gray floor tile

CW120, CW120A, CW120B 256 sf

E Black mastic under 12” green floor tile

CW120, CW120A, CW120B 256 sf

F Black lab table tops CE180 3 sf

G Carpeting over tile/mastic CE118, CE119C 336 sf

H

Fluorescent Light Tubes and CFL Bulbs

All patient rooms, hallways, offices, restrooms, and storage rooms

560 ea.

I

PCB containing ballasts for fluorescent light fixtures

All patient rooms, hallways, offices, restrooms, storage rooms

280 ea.

J

Batteries in exit and emergency light fixtures

All exit doors and hallways in renovation areas

26 ea.

K

Assumed lead-based paint All patient rooms, hallways, offices, restrooms, storage rooms

Unknown

ROOM # A B C D E F G H I J K

ALL

CORRIDORS X

X X X X

ALL FOYERS X X X X

CE118 X X X X X

CE119 X X X X

CE119A X X X X

CE119B X X X X

CE119C X X X X X

CE120 X X X X X

CE121 X X X X

CE122 X X X X X

CE123 X X X X

CE124 X X X X

CE125 X X X X X

CE126 X X X X X

CE126A X X X X

CE127 X X X X

CE127A X X X X

CE127B X X X X

CE130 X X X X

CE131 X X X X

CE132 X X X X

CE133 X X X X X

CE134 X X X X X

CE135 X X X X X

CE136 X X X X

CE137 X X X X X

CE138 X X X X

CE139 X X X X X

CE140 X X X X

CE141 X X X X

CE142 X X X X

CE143 X X X X

CE144 X X X X X

CE145 X X X X X

CE146 X X X X

CE147 X X X X X

CE148A X X X X

CE152 X X X X

CE153 X X X X

CE154 X X X X

CE155 X X X X X

CE156 X X X X

CE157 X X X X

CE158 X X X X

CE159 X X X X

CE160 X X X X

CE162 X X X X

CE163 X X X X

CE165 X X X X

CE165A X X X X

CE166 X X X X

CE167 X X X X

CE168 X X X X

CE169 X X X X

CE170 X X X X

CE171 X X X X

CE172 X X X X

CE173 X X X X

CE175 X X X X

CE176 X X X X

CE177 X X X X

ROOM # A B C D E F G H I J K

CE178 X X X X

CE179 X X X X

CE180 X X X X X

CE181 X X X

CE181A X X X

CE182 X X X X

CE183 X X X X

CE185 X X X X

CE185A X X X X

CE186 X X X X

CE187 X X X X

CE188 X X X X

CE189 A-C X X X X

CE191 X X X X

CE191A X X X X

CE192 X X X X

CE193 X X X X

CW113 X X X X

CW114 X X X X

CW115 X X X X

CW119 X X X X

CW120 X X X X X

CW120 A-C X X X X X

CW123A X X X X

CW127B X X X X

CW130 X X X X

CW132 X X X

CW133 X X X X

CW139 X X X X

CW139A X X X X

CW166B X X X X