S02_RFP Attachment_38 Insterstitial.pdf

PDF 2 MB Posted

Attached to
6350--FY23: STATION (PROJ: 673-22-107) D/B: Renovate Fire Alarm System
Solicitation number
36C24823R0036
Issued by

About this file

This document contains three electrical floor plan drawings for a renovation project at the James A. Haley VA Medical Center in Tampa, Florida. The drawings depict the power and fire alarm systems for various areas and levels, and include details such as room labels, circuit numbers, notes and matchlines. This renovation is the subject of Solicitation Number 36C24823R0036 for a project to upgrade the facility's fire alarm system. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration VISN 8 for Project Number 673-22-107. Responses are due as specified in the solicitation document. The renovation drawings provide relevant context regarding the scope of work.

View the file

Other files

File Type Posted
S02_RFP Attachment_INSTRUCTIONS TO OFFERORS AND EVALUATION INFORMATION_Fire Alarm System_Final.docx DOCX document
S05_RFI Tracking Log_Phase Two_673_22_107 DB Renovate Fire Alarm System_Final.docx DOCX document
S04_Phase Two Site Visit Sign In_Fire Alarm_23Mar2023.pdf PDF
36C24823R0036 0006.docx DOCX document
S02_RFP Attachment_AHERA Survey.pdf PDF
36C24823R0036 0005.docx DOCX document
P03_JA_OVER_SAT_Fire Alarm System_Signed_HCA_Redacted.pdf PDF
36C24823R0036 0004.docx DOCX document
S05_RFI Tracking Log PN 673_22_107 DB Renovate Fire Alarm System System_8Feb2023.docx DOCX document
36C24823R0036 0003.docx DOCX document
S02_RFP Attachment_INSTRUCTIONS TO OFFERORS AND EVALUATION INFORMATION_Fire Alarm System_Updated.docx DOCX document
S02_RFP Attachment_Bldg 55 Elec_FA.pdf PDF
S02_RFP Attachment_38 4th floor.pdf PDF
36C24823R0036 0002.docx DOCX document
S05_RFI Tracking Log 673_22_107 DB Renovate Fire Alarm System_Final.docx DOCX document
S02_RFP Attachment_SPEC 00 11 21_RFP 673_22_107 Renovate Fire Alarm System_Updated.docx DOCX document
S02_RFP Attachment_Bldg 38 _ 3rd Floor FA and Nurse call.pdf PDF
S02_RFP Attachment_Bldg 38 _ 2nd floor Polytrauma Fire Alarm and Nurse Call.pdf PDF
36C24823R0036 0001.docx DOCX document
Experience Information Sheet.docx DOCX document
S02_RFP Attachment_SPEC 01 00 00_General Requirements 673-22-107.docx DOCX document
S02_RFP Attachment_SPEC 28 05 00_Common Work Results for Electronic Safety and Security.docx DOCX document
S02_RFP Attachment_SPEC 01 32 16 16_Network Analysis Schedule_Design-Build Only.docx DOCX document
S02_RFP Attachment_DB Wage Rate FL20220208 dtd 09.09.22.txt TXT text file
S02_RFP Attachment_SPEC 21 13 13_Wet-Pipe Sprinkler Systems.docx DOCX document
S02_RFP Attachment_SPEC 01 35 26_Safety Requirements 673-22-107.docx DOCX document
S02_RFP Attachment_SPEC 28 05 26_Grounding and Bonding for Electronic Safety and Security.docx DOCX document
S02_RFP Attachment_Past Performance Questionnaire.pdf PDF
S02_RFP 36C24823R0036_Final.docx DOCX document
S02_RFP Attachment_SPEC 08 71 00_Door Hardware.docx DOCX document
S02_RFP Attachment_VA HALEY FA ASBUILT.pdf PDF
S02_RFP Attachment_Tampa site map.pdf PDF
S02_RFP Attachment_SPEC 28 13 00_Physical Access Control System.docx DOCX document
S02_RFP Attachment_Contractor Trade Memo 673-22-107 Renovate Fire Alarm System.docx DOCX document
36C24823R0036_1.docx DOCX document
S02_RFP Attachment_EMR.pdf PDF
S02_RFP Attachment_SPEC 01 33 23_Shop Drawings 673-22-107.docx DOCX document
S02_RFP Attachment_SPEC 28 31 00_Fire Detection and Alarm_Combined Job Specific 673-22-107.docx DOCX document
S02_RFP Attachment_SPEC 00 11 21_RFP 673-22-107 Renovate Fire Alarm System.docx DOCX document
S02_RFP Attachment_SPEC 28 05 13_ Conductors and Cables for Electronic Safety and Security.docx DOCX document
S02_RFP Attachment_INSTRUCTIONS TO OFFERORS AND EVALUATION INFORMATION_Fire Alarm System.docx DOCX document
S02_RFP Attachment_SPEC 28 08 00_Commissioning of Electronic Safety and Security Systems.docx DOCX document
S02_RFP Attachment_Price Matrix.xlsx XLSX spreadsheet
S02_RFP Attachment_SPEC 28 05 28.33_Conduits and Backboxes for Electronic Safety and Security Systems.docx DOCX document
S02_RFP Attachment_SPEC 01 42 19_Reference Standards 673-22-107.docx DOCX document
S02_RFP Attachment_SPEC 07 84 00_Firestopping.docx DOCX document
Show all 46

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ELEV. P5

P5-38

ELEV. P6

P6-38

STAIR 1

AS01-38

FAN ROOM

A101-38

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S

S S

S

S S

S S

S S

S S

S S

S S

S S

S S

S S

MATCHLINE

G A

MATCHLINE A

J

0.2

0.18

0.12

0.1

0.07

6.2

1.7

1.5

0.23

1.6

0.8

0.11

0.09

0.24

M A

TC

H

LI

N

E

AH G F.6 F.4 F D.9 D.5 D.1 D C.4 C B.7 B.4 B.1 A.9 A EC.2 .5AA.3BF.7 B.6 0.8AG1

14499 N. Dale Mabry Hwy Suite 179 Tampa, FL., USA 33618-2042 Tel: 1-813-374-2121

FL. C.O.A. #: 27620

ENGINEERING GROUP

H A L L

Electrical Engineering Design

Signature Date

KEY PLAN

H

KH AE

ELECTRICAL - FLOOR PLAN - LEVEL

ONE AREA "A" - POWER AND FIRE

ALARM

EP-101A

1 01/21/2010 Amendment

Z

P ro je ct s\

B V

A P o ly tr au m a

E xp an si o n \D ra w in g s\

E le ct ri ca l\ P o st

-C D

\9 E P-

A .d w g

Ja n /2

/2

:4 p m

STAIR 2

BS02-38

MECHANICAL

ROOM

HM01-38

STAIR 2

HS02-38

ELEV. 7

P7-38

HM02-38A HM02-38B

CORRIDOR

HM02-38

MATCHLINEB

H

MATCHLINE

C B

0.2

0.18

0.12

0.1

0.07

6.2

1.7

1.5

0.29

0.28

0.27

0.26

0.23

1.6

0.8

0.11

0.09

0.24

M A

TC

H

LI

N

E

AHP N M L J GH.9J.6S.6 Q.7 S.1 Q M.5 M.1 J.8M.9P.5Q.1Q.5S.3 ST J.9 H G1

14499 N. Dale Mabry Hwy Suite 179 Tampa, FL., USA 33618-2042 Tel: 1-813-374-2121

FL. C.O.A. #: 27620

ENGINEERING GROUP

H A L L

Electrical Engineering Design

ELECTRICAL - FLOOR PLAN - LEVEL

ONE AREAS "B" AND "H" - POWER

AND FIRE ALARM

EP-101BH

P ro je ct s\

B V

A P o ly tr au m a

E xp an si o n \D ra w in g s\

E le ct ri ca l\ P o st

-C D

\9 E P-

B H

.d

/2

/2

FAN ROOM

C101-38

EXIT CORR

C102-38

FAN R

G101

INTERSTITIAL

MECH. ROOM

C01-38

SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS

RF.9

RE

RD.5

RD

RB.1

R3

R2

R1

MATCHLINE

C B

15.2

12.4

12.8

11.4

B10

9.8

12.3

13.6

12.5

TC

H

LI

N

E

GC

P N M L J G F.6H.9J.6Q.7 S.1 Q M.5 M.1 F.7J.8M.9P.5Q.1Q.5S.3 S J.9 H G1

14499 N. Dale Mabry Hwy Suite 179 Tampa, FL., USA 33618-2042 Tel: 1-813-374-2121

FL. C.O.A. #: 27620

ENGINEERING GROUP

H A L L

Electrical Engineering Design

ONE AREA "C" - POWER AND FIRE

ALARM

EP-101C

P ro je ct s\

B V

A P o ly tr au m a

E xp an si o n \D ra w in g s\

E le ct ri ca l\ P o st

-C D

\9 E P-

C .d

/2

/2

STAIR 4

GS04-38

ELEV. P2

P2-38

ELEV. P3

P3-38

STAIR 4

GS04-38

VESTIBULE

G103-38

RR

FAN ROOM

G101-38

CORRIDOR

G102-38

S S

S

SS

SSSS

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S S

S

S

S S

S S

S S

S

S S

S

S S S S S S S S

MATCHLINE

G A

15.2

12.4

12.8

B10

9.8

12.3

13.6

12.5

M A

TC

H

LI

N

E

GC

F.6 F.4 F D.9 D.5 D.1 D C.4 C B.7 B.4 B.1 A.9 A EC.2 .5AA.3BF.7 B.6 0.8A

14499 N. Dale Mabry Hwy Suite 179 Tampa, FL., USA 33618-2042 Tel: 1-813-374-2121

FL. C.O.A. #: 27620

ENGINEERING GROUP

H A L L

Electrical Engineering Design

ONE AREA "G" - POWER AND FIRE

ALARM

EP-101G

P ro je ct s\

B V

A P o ly tr au m a

E xp an si o n \D ra w in g s\

E le ct ri ca l\ P o st

-C D

\9 E P-

G

.d

/2

/2

:3

File details come from the government source that posted it. Updated .