Attachment 0005 F- Appendix B - Building 2.pdf
PDF 2 MB Posted
- Attached to
- 679-22-106 Replace HVAC Various Buildings Federal contract opportunity
- Solicitation number
- 36C24725R0031
About this file
This document is an appendix (Appendix B) containing XRF (X-Ray Fluorescence) testing data for Building 2 at the VAMC (Veterans Affairs Medical Center) in Tuscaloosa, Alabama. The appendix includes three sections: XRF testing data sheets, XRF testing location plans, and photographic documentation. The testing was conducted on July 31, 2014 by Safety Environmental Laboratories, Inc. for a lead-based paint inspection project (SELC Project #2014-1107).
The XRF testing data covers multiple floors (ground, first, second, and attic) and examines various building components including walls, doors, door frames, metal surfaces, and other architectural elements. The testing used a Niton XLP 700-303A analyzer with an action level of 1.00 mg/cm². Most tested components showed negative results for lead, though some specific components like a metal stringer (reading #19) showed elevated lead content of 4.60 mg/cm². The photographic documentation highlights two specific instances of damaged lead-based paint (LBP): one on a metal roof drain pipe and another on a crawlspace vent on the exterior of the building.
View the file
Other files for this federal contract opportunity
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX B
BUILDING 2
MENTAL HEALTH BUILDING / OFFICES
INCLUDED IN APPENDIX B:
B‐1 – XRF Testing Data Sheets
B‐2 – XRF Testing Location Plans
B‐3 – Photographic Documentation
APPENDIX B‐1
XRF Testing Data Sheets
XRF TESTING DATA
VAMC TUSCALOOSA
BUILDING 2
3701 PELHAM LOOP ROAD EAST
TUSCALOOSA, AL 35404
SELC PROJECT #: 2014‐1107
NITON XLP 700‐303A
Serial #21385
Reading Lead
Number (mg/cm2)
1 7/31/2014 10:19 1.51* 2 7/31/2014 10:54 0.90 3 7/31/2014 10:55 0.90 4 7/31/2014 10:57 1.00 5 7/31/2014 11:08 Chair Rail Wood C Intact White Interior Ground Bldg 2 16 NP Negative 0.00 6 7/31/2014 11:09 Door Metal A Intact Brown Interior Ground Bldg 2 16 NP Negative 0.00 7 7/31/2014 11:10 Door Frame Metal A Intact Brown Interior Ground Bldg 2 16 NP Negative 0.00 8 7/31/2014 11:12 Wall Gypsum Board B Intact White Interior Ground Bldg 2 1c NP Negative 0.00 9 7/31/2014 11:13 Door Metal D Intact Brown Interior Ground Bldg 2 1c NP Negative 0.01 10 7/31/2014 11:13 Door Frame Metal D Intact Brown Interior Ground Bldg 2 1c NP Negative 0.00 11 7/31/2014 11:15 Door Frame Metal D Intact Brown Interior Ground Bldg 2 7b NP Null 0.00 12 7/31/2014 11:15 Door Frame Metal A Intact Brown Interior Ground Bldg 2 7b NP Negative 0.01 13 7/31/2014 11:17 Wall Gypsum Board C Intact White Interior Ground Bldg 2 24 NP Negative 0.01 14 7/31/2014 11:18 Radiator Metal D Intact White Interior Ground Bldg 2 24 NP Positive 1.80 15 7/31/2014 11:22 Wall Gypsum Board A Intact White Interior Ground Bldg 2 cg4 NP Negative 0.01 16 7/31/2014 11:24 Fire Ext. Cab. Door Metal D Intact Red Interior Ground Bldg 2 cg5 NP Negative 0.01
17 7/31/2014 11:26 Wall Plaster A Intact White Interior Ground Bldg 2 Stairwell sc‐1 NP Negative 0.13
18 7/31/2014 11:26 Stringer Metal B Intact White Interior Ground Bldg 2 Stairwell sc‐1 NP Positive 2.90
19 7/31/2014 11:30 Stringer Metal C Intact White Interior First Bldg 2 Stairwell 123 NP Positive 4.60
20 7/31/2014 11:31 Door Metal C Intact White Interior First Bldg 2 Stairwell 123 NP Negative 0.01
21 7/31/2014 11:32 Door Frame Metal C Intact White Interior First Bldg 2 Stairwell 123 NP Negative 0.00
22 7/31/2014 11:32 Wall Plaster C Intact White Interior First Bldg 2 Stairwell 123 NP Negative 0.14
Date & Time Component Substrate Side Condition Results
Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573 Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573 Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573
Color Location Floor Building Room Inspector
ACTION LEVEL = 1.00 mg/cm2
BUILDING 2
3701 PELHAM LOOP ROAD EAST
TUSCALOOSA, AL 35404
SELC PROJECT #: 2014‐1107
NITON XLP 700‐303A
Serial #21385
Reading Lead
Number (mg/cm2) Date & Time Component Substrate Side Condition ResultsColor Location Floor Building Room Inspector
23 7/31/2014 11:33 Ceiling Plaster C Cracked White Interior First Bldg 2 Stairwell 123 NP Null 0.08
24 7/31/2014 11:33 Ceiling Plaster C Cracked White Interior First Bldg 2 Stairwell 123 NP Negative 0.06
25 7/31/2014 11:36 Wall Plaster B Intact White Interior First Bldg 2 109 NP Negative 0.40 26 7/31/2014 11:37 Door Frame Metal D Intact Brown Interior First Bldg 2 109 NP Negative 0.01 27 7/31/2014 11:39 Door Frame Metal B Intact Brown Interior First Bldg 2 Corridor 125 NP Negative 0.00 28 7/31/2014 11:39 Door Metal B Intact Brown Interior First Bldg 2 Corridor 125 NP Negative 0.01 29 7/31/2014 11:40 Wall Plaster A Intact White Interior First Bldg 2 104 NP Negative 0.07 30 7/31/2014 11:42 Column Plaster B Intact Beige Interior First Bldg 2 101 NP Negative 0.10 31 7/31/2014 11:43 Door Frame Metal C Intact Brown Interior First Bldg 2 101 NP Negative 0.00 32 7/31/2014 11:46 Wall Plaster C Intact White Interior First Bldg 2 115 NP Positive 1.70 33 7/31/2014 11:48 Fire Ext. Cab. Door Metal D Intact Red Interior First Bldg 2 Corridor 179 NP Negative 0.04 34 7/31/2014 11:49 Wall Gypsum Board B Intact Beige Interior First Bldg 2 113c NP Negative 0.00 35 7/31/2014 11:50 Wall Gypsum Board D Intact Beige Interior First Bldg 2 113c NP Negative 0.00 36 7/31/2014 11:52 Door Frame Metal D Intact Brown Interior First Bldg 2 113g NP Negative 0.00 37 7/31/2014 11:54 Wall Gypsum Board D Intact Beige Interior First Bldg 2 113g NP Negative 0.00
38 7/31/2014 11:57 Wall Plaster B Intact White Interior First Bldg 2 Stairwell 113c NP Negative 0.12
39 7/31/2014 11:58 Stringer Metal B Intact Gray Interior First Bldg 2 Stairwell 113c NP Positive 3.50
40 7/31/2014 11:59 Door Metal A Intact White Interior First Bldg 2 Stairwell 113c NP Negative 0.06
41 7/31/2014 12:00 Door Frame Metal A Intact White Interior First Bldg 2 Stairwell 113c NP Negative 0.08
42 7/31/2014 12:07 Wall Plaster C Cracked Beige Interior Second Bldg 2 205 NP Negative 0.01 43 7/31/2014 12:07 Door Frame Metal A Cracked Brown Interior Second Bldg 2 205 NP Negative 0.00 44 7/31/2014 12:08 Door Frame Metal C Intact Brown Interior Second Bldg 2 204 NP Negative 0.02
BUILDING 2
3701 PELHAM LOOP ROAD EAST
TUSCALOOSA, AL 35404
SELC PROJECT #: 2014‐1107
NITON XLP 700‐303A
Serial #21385
Reading Lead
Number (mg/cm2) Date & Time Component Substrate Side Condition ResultsColor Location Floor Building Room Inspector
45 7/31/2014 12:08 Wall Plaster A Intact White Interior Second Bldg 2 204 NP Negative 0.14 46 7/31/2014 12:11 Wall Plaster D Intact Beige Interior Second Bldg 2 Corridor 219 NP Negative 0.00 47 7/31/2014 12:13 Wall Gypsum Board C Intact White Interior Second Bldg 2 212b NP Negative 0.00 48 7/31/2014 12:14 Door Frame Metal A Intact Gray Interior Second Bldg 2 212b NP Negative 0.01 49 7/31/2014 12:14 Door Metal A Intact Gray Interior Second Bldg 2 212b NP Negative 0.01 50 7/31/2014 12:15 Door Metal D Intact Brown Interior Second Bldg 2 212d NP Negative 0.00 51 7/31/2014 12:17 Wall Plaster A Intact White Interior Second Bldg 2 213b NP Negative 0.00 52 7/31/2014 12:22 Window Sill Wood A Intact White Interior Attic Bldg 2 NP Positive 14.70 53 7/31/2014 12:23 Sprinkler Pipe Metal B Intact Red Interior Attic Bldg 2 NP Negative 0.04 54 7/31/2014 12:34 Sprinkler Pipe Metal A Intact Red Interior Attic Bldg 2 NP Negative 0.00 55 7/31/2014 12:35 Duct Metal Central Intact Orange Interior Attic Bldg 2 NP Positive 8.90 56 7/31/2014 12:36 Duct Metal Central Intact Orange Interior Attic Bldg 2 NP Positive 10.10 57 7/31/2014 12:36 Pipe Metal Central Poor Beige Interior Attic Bldg 2 NP Positive 10.10 58 7/31/2014 12:38 Floor Concrete Central Intact Gray Interior Attic Bldg 2 Elevator NP Negative 0.50 59 7/31/2014 12:39 Floor Concrete Central Intact Red Interior Attic Bldg 2 Elevator NP Negative 0.30 60 7/31/2014 12:39 Ladder Metal B Intact Gray Interior Attic Bldg 2 Elevator NP Positive 7.70 61 7/31/2014 12:39 Door Metal B Intact Gray Interior Attic Bldg 2 Elevator NP Positive 2.10 62 7/31/2014 12:40 Door Frame Metal B Intact Gray Interior Attic Bldg 2 Elevator NP Positive 2.00 63 7/31/2014 12:40 Duct Metal C Intact Gray Interior Attic Bldg 2 Elevator NP Positive 9.70 64 7/31/2014 12:42 Cage Metal Central Intact Green Interior Attic Bldg 2 Elevator NP Negative 0.26 65 7/31/2014 12:45 Motor Metal A Intact Blue Interior Attic Bldg 2 Elevator NP Negative 0.00
66 7/31/2014 13:30 Wall Brick A Intact White Interior Ground Bldg 2 Mechanical 8a NP Negative 0.00
67 7/31/2014 13:30 Door Metal A Intact White Interior Ground Bldg 2 Mechanical 8a NP Negative 0.00
68 7/31/2014 13:31 Door Frame Metal A Intact White Interior Ground Bldg 2 Mechanical 8a NP Negative 0.01
BUILDING 2
3701 PELHAM LOOP ROAD EAST
TUSCALOOSA, AL 35404
SELC PROJECT #: 2014‐1107
NITON XLP 700‐303A
Serial #21385
Reading Lead
Number (mg/cm2) Date & Time Component Substrate Side Condition ResultsColor Location Floor Building Room Inspector
69 7/31/2014 13:32 Wall Metal C Intact White Interior Ground Bldg 2 Mechanical 8a NP Negative 0.02
70 7/31/2014 13:33 Door Metal C Intact White Interior Ground Bldg 2 Mechanical 8a NP Negative 0.00
71 7/31/2014 13:33 Door Frame Metal C Intact White Interior Ground Bldg 2 Mechanical 8a NP Negative 0.00
72 7/31/2014 13:34 Ceiling Concrete C Peeling White Interior Ground Bldg 2 Mechanical 8a NP Negative 0.01
73 7/31/2014 13:35 Motor Metal C Intact Red Interior Ground Bldg 2 Mechanical 8a NP Negative 0.02
74 7/31/2014 13:35 Motor Metal C Intact Red Interior Ground Bldg 2 Mechanical 8a NP Negative 0.00
75 7/31/2014 13:36 Stairs Metal B Intact Black Interior Ground Bldg 2 Mechanical 8a NP Positive 8.40
76 7/31/2014 13:36 Handrail Metal B Intact Black Interior Ground Bldg 2 Mechanical 8a NP Positive 1.60
77 7/31/2014 13:38 Window Frame Metal C Intact White Exterior Ground Bldg 2 Mechanical 8a NP Negative 0.00
78 7/31/2014 13:39 Window Lintel Metal C Intact White Exterior Ground Bldg 2 NP Positive 1.20 79 7/31/2014 13:40 Window Lintel Metal B Intact White Exterior Ground Bldg 2 NP Negative 0.70 80 7/31/2014 13:41 Crawlspace Vent Metal B Poor White Exterior Ground Bldg 2 NP Positive 20.70 142 7/31/2014 15:18 1.00 143 7/31/2014 15:21 1.00 144 7/31/2014 15:22 1.00 145 7/31/2014 15:23 0.90
* = Reading number 1 is an internal diagnostic reading that does not represent lead content on any items.
Null = Incomplete test due to instrument movement or early trigger release.
Reading numbers 81 ‐ 141 apply to Building 12, also tested on same date. Please see corresponding building table for this data.
Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573 Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573 Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573 Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573
APPENDIX B‐2
XRF Testing Location Plans
APPENDIX B‐3
Photographic Documentation
Building 2 Photographic Documentation
SELC Project # 2014-1107 Page 1
Photograph 1 Damaged LBP on metal roof drain pipe.
Photograph 2 Damaged/deteriorated LBP on crawlspace vent on exterior.
NO PHOTOGRAPH NO PHOTOGRAPH
| Appendix B Cover Sheet B2 |
| Appendix B Divider Pages |
| BUILDING 2 DRAWINGS.pdf |
| 2014-1107 - B2 - SHEET 1 OF 4 |
| 2014-1107 - B2 - SHEET 2 OF 4 |
| 2014-1107 - B2 - SHEET 3 OF 4 |
| 2014-1107 - B2 - SHEET 4 OF 4 |
File details come from the government source that posted it. Updated .