Attachment 0005 D - Appendix S - Building 46.pdf

PDF 1 MB Posted

Attached to
679-22-106 Replace HVAC Various Buildings Federal contract opportunity
Solicitation number
36C24725R0031
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 7

About this file

This document is an Appendix S for Building 46 at the VAMC Tuscaloosa, containing XRF (X-Ray Fluorescence) Testing Data and Photographic Documentation for lead-based paint (LBP) inspection. The testing was conducted on July 2-3, 2014 by Safety Environmental Laboratories, Inc. for SELC Project #2014-1107, using a Niton XLP 700-303A analyzer.

The XRF testing data includes 87 readings across various interior and exterior components of Building 46, such as walls, ceilings, doors, window sills, and structural elements. The action level was set at 1.00 mg/cm², with most readings being negative for lead content. However, several exterior components showed positive lead-based paint results, including handrails (7.30 and 2.40 mg/cm²), a decorative wooden grill (6.60 mg/cm²), metal door and frame (7.40 and 12.00 mg/cm²), and a downspout base (1.10 mg/cm²). The photographic documentation visually captures the damaged and peeling lead-based paint on various building surfaces, supporting the XRF testing findings.

View the file

Other files for this federal contract opportunity

Other files attached to 679-22-106 Replace HVAC Various Buildings, newest first.
File Type Posted
Amendment 0006 36C24725R0031.pdf PDF
Attachment 0005 G -Addendum 1 Drawings.pdf PDF
Amendment 0005 36C24725R0031.pdf PDF
Attachment 0005 C - Appendix P - Building 46.pdf PDF
Attachment 0005 E- Addendum 1 Change Narrative.pdf PDF
Attachment 0005 A- Pre-Bid RFIs_Responses.pdf PDF
Attachment 0005 B - Appendix B - Building 2.pdf PDF
Attachment 0005 F- Appendix B - Building 2.pdf PDF
Attachment 0005 H-Wage DBA AL20250098.txt TXT text file
Amendment 36C24725R0031 0004.pdf PDF
Amendment 36C24725R0031 0003.pdf PDF
Amendment 36C24725R0031 0002.pdf PDF
679-22-106 -Replace HVAC Various Buildings Site Visit.pdf PDF
Amendment 36C24725R0031 0001.pdf PDF
Attachment 6 - INVOICING.docx DOCX document
Attachment 5 -DBA Number AL20240136.pdf PDF
679-22-106 Specifications.pdf PDF
Solicitation 36C24725R0031.pdf PDF
Attachment 3 - Past Performance Questionnaire -PPQ.docx DOCX document
Attachment 2 - VAAR 852.219-75 VA Notice of Limitations on Subcontracting Jan 2023 Deviation.pdf PDF
Attachment 1 - Experience Modification Rate Form.pdf PDF
Attachment 4 - Itemized Cost Breakdown.xlsx XLSX spreadsheet
679-22-106_Drawings.pdf PDF
Show all 23

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX S

BUILDING 46

CHAPEL

INCLUDED IN APPENDIX S:

S‐1 – XRF Testing Data Sheets

S‐2 – XRF Testing Location Plans

S‐3 – Photographic Documentation

APPENDIX S‐1

XRF Testing Data Sheets

XRF TESTING DATA

VAMC TUSCALOOSA

BUILDING 46

3701 PELHAM LOOP ROAD EAST

TUSCALOOSA, AL 35404

SELC PROJECT #: 2014‐1107

NITON XLP 700‐303A

Serial #21385

Reading Lead

Number (mg/cm2)

1 7/2/2014 10:46 1.49* 2 7/2/2014 10:50 0.90 3 7/2/2014 10:51 1.10 4 7/2/2014 10:51 1.20 23 7/2/2014 14:19 Ceiling Concrete A Intact White Interior 1 Bldg 46 NP Negative 0.00 24 7/2/2014 14:22 Wall CMU D Intact Beige Interior 1 Bldg 46 NP Negative 0.04 25 7/2/2014 14:25 Arch Plaster D Intact Brown Interior 1 Bldg 46 NP Negative 0.03 26 7/2/2014 14:25 Arch Plaster B Intact Brown Interior 1 Bldg 46 NP Negative 0.02 27 7/2/2014 14:26 Window Sill Wood D Intact White Interior 1 Bldg 46 NP Negative 0.01 28 7/2/2014 14:28 Wall Panel Wood C Intact Gray Interior 1 Bldg 46 NP Negative 0.01 29 7/2/2014 14:28 Ceiling Wood C Intact Beige Interior 1 Bldg 46 NP Negative 0.01 30 7/2/2014 14:29 Ceiling Wood C Intact Beige Interior 1 Bldg 46 NP Negative 0.01 31 7/2/2014 14:30 Duct Cover Wood A Intact White Interior 1 Bldg 46 NP Negative 0.01 32 7/2/2014 14:30 Duct Cover Wood C Intact White Interior 1 Bldg 46 NP Negative 0.00 33 7/2/2014 14:31 Door Wood D Intact Brown Interior 1 Bldg 46 NP Negative 0.04 34 7/2/2014 14:32 Door Frame Metal D Intact Brown Interior 1 Bldg 46 NP Negative 0.04 35 7/2/2014 14:35 Door Frame Metal A Intact Cream Interior Corridor 5 Bldg 46 NP Negative 0.00 36 7/2/2014 14:36 Wall CMU B Intact Cream Interior Corridor 5 Bldg 46 NP Negative 0.50 37 7/2/2014 14:38 Door Metal B Intact Gray Interior Rm 6 Bldg 46 NP Negative 0.03 38 7/2/2014 14:38 Door Frame Metal B Intact Gray Interior Rm 6 Bldg 46 NP Negative 0.02 39 7/2/2014 14:41 Window Sill Wood D Intact White Interior Rm 8 Bldg 46 NP Negative 0.03 40 7/2/2014 14:42 Closet Door Wood C Intact Gray Interior Rm 8 Bldg 46 NP Negative 0.03 41 7/2/2014 14:42 Closet Door Frame Metal C Intact Gray Interior Rm 8 Bldg 46 NP Negative 0.03 42 7/2/2014 14:44 Closet Door Frame Metal D Intact Gray Interior Rm 11 Bldg 46 NP Negative 0.01 43 7/2/2014 14:44 Closet Door Wood D Intact Gray Interior Rm 11 Bldg 46 NP Negative 0.08 44 7/2/2014 14:45 Wall CMU A Intact White Interior Rm 11 Bldg 46 NP Negative ‐0.21 45 7/2/2014 14:45 Wall CMU A Intact White Interior Rm 11 Bldg 46 NP Negative ‐0.26 46 7/2/2014 14:47 Wall CMU C Intact White Interior Rm 10 Bldg 46 NP Negative 0.17

ResultsColor Location Room Building Inspector

Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573 Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573 Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573

Date & Time Component Substrate Side Condition

ACTION LEVEL = 1.00 mg/cm2

BUILDING 46

3701 PELHAM LOOP ROAD EAST

TUSCALOOSA, AL 35404

SELC PROJECT #: 2014‐1107

NITON XLP 700‐303A

Serial #21385

Reading Lead

Number (mg/cm2) ResultsColor Location Room Building InspectorDate & Time Component Substrate Side Condition

47 7/2/2014 14:48 Floor Concrete Intact Gray Interior Rm 10 Bldg 46 NP Negative 0.03 48 7/2/2014 14:49 Radiator Cover Metal C Intact White Interior Rm 10 Bldg 46 NP Negative 0.01 49 7/2/2014 14:50 Window Sill Wood C Intact White Interior Rm 9 Bldg 46 NP Negative 0.07 50 7/2/2014 14:51 Closet Door Wood A Intact White Interior Rm 9 Bldg 46 NP Negative 0.03 51 7/2/2014 14:52 Closet Door Frame Metal A Intact White Interior Rm 9 Bldg 46 NP Negative 0.06 52 7/2/2014 14:54 Floor Concrete A Intact Gray Interior Rm 5a Bldg 46 NP Negative 0.00 53 7/2/2014 14:55 Floor Concrete A Intact Gray Interior Rm 12 Bldg 46 NP Negative 0.00 54 7/2/2014 14:59 Wall Gypsum Board B Intact White Interior Rm 3 Bldg 46 NP Negative 0.00 55 7/2/2014 14:59 Wall Gypsum Board B Intact White Interior Rm 3 Bldg 46 NP Negative 0.01 56 7/2/2014 15:07 Floor Concrete B Poor Gray Interior Rm 4 Bldg 46 NP Negative 0.05 57 7/2/2014 15:08 Handrail Metal D Intact Yellow Interior Rm 4 Bldg 46 NP Positive 7.30 58 7/2/2014 15:09 Handrail Metal D Intact Yellow Interior Rm 4 Bldg 46 NP Positive 2.40 59 7/2/2014 15:37 Equipment Stand Concrete A Intact Yellow Interior Rm 4 Bldg 46 NP Negative 0.09 60 7/2/2014 15:37 Equipment Stand Concrete A Intact Yellow Interior Rm 4 Bldg 46 NP Negative 0.11 61 7/2/2014 15:39 Structural Steel Metal A Intact Black Interior Rm 4 Bldg 46 NP Negative 0.00 62 7/2/2014 15:39 Structural Steel Metal A Intact Black Interior Rm 4 Bldg 46 NP Negative 0.00 63 7/2/2014 15:39 Structural Steel Metal A Intact Black Interior Rm 4 Bldg 46 NP Negative 0.00 64 7/2/2014 15:41 Door Metal B Intact Gray Interior Rm 4 Bldg 46 NP Negative 0.06 65 7/2/2014 15:41 Door Frame Metal B Intact Gray Interior Rm 4 Bldg 46 NP Negative 0.01 66 7/2/2014 15:58 0.90 67 7/2/2014 16:00 1.00 68 7/2/2014 16:01 0.90 69 7/3/2014 8:22 1.39* 70 7/3/2014 8:49 0.80 71 7/3/2014 8:49 1.10 72 7/3/2014 8:50 0.90 73 7/3/2014 9:00 Ceiling Concrete A Intact White Exterior Bldg. 46 NP Null 0.03 74 7/3/2014 9:00 Ceiling Concrete A Intact White Exterior Bldg. 46 NP Negative 0.02

Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573 Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573 Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573

Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573

Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573 Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573

BUILDING 46

3701 PELHAM LOOP ROAD EAST

TUSCALOOSA, AL 35404

SELC PROJECT #: 2014‐1107

NITON XLP 700‐303A

Serial #21385

Reading Lead

Number (mg/cm2) ResultsColor Location Room Building InspectorDate & Time Component Substrate Side Condition

75 7/3/2014 9:04 Sign Metal A Intact Black Exterior Bldg. 46 NP Positive 1.40 76 7/3/2014 9:11 Decorative Grill Wood A Peeling White Exterior Bldg. 46 NP Positive 6.60

77 7/3/2014 9:21 Downspout Factory Coated Aluminum

B Intact White Exterior Bldg. 46 NP Negative 0.00

78 7/3/2014 9:22 Downspout Base Metal B Poor Black Exterior Bldg. 46 NP Positive 1.10 79 7/3/2014 9:30 Door Metal B Poor White Exterior Bldg. 46 NP Positive 7.40 80 7/3/2014 9:30 Door Frame Metal B Poor White Exterior Bldg. 46 NP Positive 12.00 81 7/3/2014 9:37 Soffit Wood A Peeling White Exterior Bldg. 46 NP Positive 16.60 82 7/3/2014 9:37 Fascia Wood A Peeling White Exterior Bldg. 46 NP Negative 0.02 83 7/3/2014 9:39 Fascia Wood A Peeling White Exterior Bldg. 46 NP Positive 7.50 84 7/3/2014 9:47 Window Lintel Metal A Peeling White Exterior Bldg. 46 NP Negative 0.00 85 7/3/2014 9:48 Window Lintel Metal A Peeling White Exterior Bldg. 46 NP Null 1.10 86 7/3/2014 9:49 Window Lintel Metal C Peeling Silver Exterior Bldg. 46 NP Positive 2.40 87 7/3/2014 9:55 Door Frame Metal D Poor White Exterior Bldg. 46 NP Positive 5.40 134 7/3/2014 13:31 1.10 135 7/3/2014 13:33 1.00 136 7/3/2014 13:35 1.00

* = Reading numbers 1 and 69 are internal diagnostic readings that do not represent lead content on any items.

Null = Incomplete test due to instrument movement or early trigger release.

Readings 5 ‐22 from 7/2/14 and 88 ‐ 133 from 7/3/14 apply to Buildings 13, 14, 25, 27, and 28. Please see corresponding building tables for this data.

Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573

Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573 Calibrate Acceptable Range, 0.8 ‐ 1.2, SRM 2573

APPENDIX S‐2

XRF Testing Location Plans

APPENDIX S‐3

Photographic Documentation

Building 46

SELC Project # 2014-1107 Page 1

Photograph 1 Damaged LPB on wooden decorative grill.

Photograph 3 Damage LBP on metal down spout base – typical.

Photograph 4 Damaged LBP on metal door and frame to

Room 4.

Photograph 2 Damaged / peeling LPB on wooden decorative grill.

Building 46

SELC Project # 2014-1107 Page 2

Photograph 6 Damaged / peeling LPB on wooden soffit and fascia – typical.

Photograph 5 Damaged / peeling LPB on wooden soffit and fascia – typical.

Photograph 7 Damaged / peeling LPB on exterior metal door frame – typical.

NO PHOTOGRAPH

APPENDIX S COVER SHEET B46