04 Series DOORS - 100 AT-125 Fort McPherson OPC.pdf

PDF 1 MB Posted

Attached to
Fire Sprinkler Testing
Solicitation number
36C24724Q0269
Issued by

About this file

This document package includes drawings and specifications for a fire sprinkler testing project at a Department of Veterans Affairs medical center. The project involves inspecting and testing fire sprinkler systems throughout multiple buildings on the VA campus to ensure compliance with NFPA standards. Key requirements include testing sprinkler piping and components, fire pumps and related equipment. The scope also involves inspecting sprinkler heads and identifying any deficiencies. The drawings provide floor plans delineating the locations of sprinkler systems, standpipes and related infrastructure in various facility areas. Relevant details are noted such as sprinkler types, pipe sizes and equipment specifications. This project appears aimed at confirming the ongoing integrity and reliability of critical life safety systems at the VA medical center.

View the file

Other files

File Type Posted
FIRE ALARM 130.pdf PDF
2022-06-20_Fort-McPherson-VAMC-Bldg-128_Annual Report.pdf PDF
BLDG 131 ASBUILTS.pdf PDF
2022-06-06_Fort-McPherson-VAMC-Bldg-131_Annual Report.pdf PDF
FIRE SUPPRESSION.pdf PDF
2022-06-20_Fort-McPherson-VAMC-Bldg-129_Annual Report.pdf PDF
BLDG 125 ASBUILT.pdf PDF
2023-02-09_Fort-McPherson-VAMC-Bldg-125_SprinklerScan.pdf PDF
2023-05-18_Fort-McPherson-VAMC-Bldg-128_SprinklerScan.pdf PDF
Ft. McPherson Bldg 128 Fire Alarm Drawings - RECORD Dwg.pdf PDF
Bldg 128 As-Builts.pdf PDF
2023-02-09_Fort-McPherson-VAMC-Bldg-130_SprinklerScan.pdf PDF
2023-05-18_Fort-McPherson-VAMC-Bldg-130_SprinklerScan.pdf PDF
FIRE ALARM 129.pdf PDF
2022-08-15_Fort-McPherson-VAMC-Bldg-131_SprinklerScan.pdf PDF
2023-05-18_Fort-McPherson-VAMC-Bldg-125_SprinklerScan.pdf PDF
BLDG 129 ASBUILT.pdf PDF
2023-02-10_Fort-McPherson-VAMC-Bldg-128_SprinklerScan (1).pdf PDF
36C24724Q0269 0001.pdf PDF
03 Series LIFE SAFETY - 100 AT-130 Fort McPherson Residental Treatment.pdf PDF
03 Series LIFE SAFETY - 100 AT-131 Fort McPherson Domiciliary Care.pdf PDF
03 Series LIFE SAFETY - 100 AT-125 Fort McPherson OPC.pdf PDF
FIRE ALARM 125.pdf PDF
2022-06-06_Fort-McPherson-VAMC-Bldg-125_Annual Report.pdf PDF
04 Series DOORS - 100 AT-130 Fort McPherson Residental Treatment.pdf PDF
2023-02-09_Fort-McPherson-VAMC-Bldg-131_SprinklerScan.pdf PDF
2022-08-15_Fort-McPherson-VAMC-Bldg-130_SprinklerScan.pdf PDF
2022-08-15_Fort-McPherson-VAMC-Bldg-128_SprinklerScan.pdf PDF
05 series dampers - 100 at-125 fort mcpherson opc.pdf PDF
FIRE SUPPRESSION 131.pdf PDF
2022-06-06_Fort-McPherson-VAMC-Bldg-130_Annual Report.pdf PDF
03 Series LIFE SAFETY - 100 AT-128 Fort McPherson Homeless Program.pdf PDF
04 Series DOORS - 100 AT-128 Fort McPherson Homeless Program.pdf PDF
BLDG. 125 FIRE SUPPRESSION.pdf PDF
04 Series DOORS - 100 AT-131 Fort McPherson Domiciliary Care.pdf PDF
2023-05-18_Fort-McPherson-VAMC-Bldg-131_SprinklerScan.pdf PDF
2023-05-18_Fort-McPherson-VAMC-Bldg-129_SprinklerScan.pdf PDF
36C24724Q0269.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INDEX OF DRAWINGSVICINITY MAP PROJECT TEAMBUILDING SUMMARYANNOTATION DRAWING SYMBOLS

OWNER

Department of Veterans Affairs Tuscaloosa VA Medical Center 3701 Loop Road East Tuscaloosa AL 35404-5088

PROJECT MANAGER

Romanyk Consulting 3308 Preston Road, Suite 350-164 Plano, TX 75093

Sherri Mitchell, Contracting Officer Sherri.mitchell@va.gov

334-272-4670, ext 2238

Joshua Leow, COR Joshua.leow@va.gov

Elijah Knight, PE, MSEM elijah.knight@romanykconsulting.com

855-424-3838 ext.323 405-640-1586 cell

MECHANICAL ENGINEER

PROJECT ARCHITECT

John Slattery, RA john.slattery@romanykconsulting.com

855-424-3838 ext.336 918-430-6020 cell

Brad Cain, PE brad.cain@romanykconsulting.com

855-424-3838 ext.335 864-908-8304 cell

Romanyk Consulting 3308 Preston Road, Suite 350-164 Plano, TX 75093

Romanyk Consulting 3308 Preston Road, Suite 350-164 Plano, TX 75093

LIFE SAFETY ENGINEER

Frank Van Overmeiren fvanovermeiren@fpc-consultants.com

317-486-5188 ext.13

FP&C Consultants, Inc.

1520 Main Street Indianapolis, IN 46224

ROOM NAME

ROOM NAME / NUMBER

NORTH ARROW

NORTH ARROW WITH TRUE

NORTH INDICATION

Name Elevation

FLOOR LEVEL &

NAME

SHEET KEYNOTE1

XXX-XXXX-XX-XXXXX DOOR TAG

1 SHEET KEYNOTE

XXX-XXX-XX-XXXXX

WALL

PENETRATION TAG

XXX-XXX-XX-DPXXX DAMPER TAG

The A/E team, including architects, engineers, surveyors, and professional consultants shall survey and inspect the following VISN 7 VA Medical Center for Life safety deficiencies according to 2015 NFPA 101 Life Safety Code and Joint Commission Standard LS.01.01.01, EP 2 and provide comprehensive as-built Life Safety Plans (LSP)

SCOPE OF WORK SUMMARY:

• Tuskegee

• Montgomery

Team shall provide a list of discrepancies based off their findings and provide recommended methods for corrections. Team shall also update the facilities current life/fire safety plans to reflect existing as-built conditions based off the survey. Team shall also survey the facility to locate existing fire dampers and provide accurate as-built drawings.

A/E shall assume all areas of the campus are, and must remain fully operational, and that inspections may require coordination with the Owner for after-hours access, accompanied access and protected access (for medically sensitive areas, etc.), and shall include all such work as part of the A/E Scope of Work (SOW).

Life Safety inspection shall include the following. Inspecting all fire walls (including doors, door frames, and hardware) smoke walls, locations of all fire extinguishers, smoke detectors, smoke compartments, and exit signs.

A/E shall reference NFPA 101 and other NFPA applicable codes and provide the follow for each deliverable.

• Columbia

• Atlanta

• Augusta UD

• Augusta DD

• Dublin

• Charleston

LS0101A

LEVEL

DISCIPLINE

SECTION LETTER

WITHIN LEVEL

SERIES

01 SERIES = TJC DRAWINGS

02 SERIES = WALL PENETRATION DEFICIENCY DRAWINGS

03A SERIES = LIFE SAFETY DRAWINGS

03B SERIES = EXIT AND OCCUPANCY DRAWINGS

04 SERIES = FIRE/SMOKE DOOR DRAWINGS

05 SERIES = FIRE/SMOKE DAMPER DRAWINGS

FIRE/SMOKE DOORS - DRAWING LIST

' 6

G ra p h ic S ca le

/2

1'

-0

G ra p h ic S ca le

/3 2"

'-0

' G ra p h ic S ca le

/1 6"

'-0

' G ra p h ic

S ca le

/8

1' -0

G ra p h ic S ca le

/4

1'

-0

G ra p h ic S ca le

/8

1'

-0

' G ra p h ic

S ca le

/2

1' -0

G ra p h ic S ca le

/4

1'

-0

G ra p h ic S ca le

'-0

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

NOT FOR

PERMITTING OR

CONSTRUCTION

A/E:Consultant:

VISN 7 LIFE SAFETY SURVEY AND

DRAWING UPDATE, TASK ORDER

#13

GS-10F-0347P

Elijah Knight, PE

VISN 7 LIFE SAFETY SURVEY AND DRAWING UPDATE

BPA ORDER NO. VA247-14-A-0028 - TASK ORDER #13

EE

ES

S

OF

M

R C

D

T

T T

II

N

U A

A A

V

RAP

M

N

T

T

OF

E E

D

R S

I

FA

A

N T

S R

F

AEE

2017 LIFE SAFETY DOCUMENTATION

FINAL

Contract: GS-10F-0347P Task Order: VA247-17-F-2259

R R o m a n y k C o n s u lt in g \R

C C

A E

C

C o n s u lt in g \0

P ro je c ts

\V

IS

N

\L if e

S a fe ty \0

M o d e l\

A tl a n ta \B u ild in g s S u rv e y e d

\A T

-1

F o rt M c P h e rs o n

O P

C \A

T -1

F o rt

M c P h e rs o n O

P C

.r v t

/1

/2

:5

:2

A M

COVER

E.K. HP

G-04

VISN 7 ATLANTA

07/31/2018

VISN 7

ATLANTA

Building 125 - FT McPHERSON OPC

100% SUBMITTAL

FIRE/SMOKE DOORS

04 - GENERAL

G-04 COVER

G-04X1 GENERAL SHEET

G-04X2 GENERAL SHEET

04 - FIRE/SMOKE DOOR

LS040B FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - BASEMENT

LS0401 FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 01

LS0402 FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 02

Grand total: 6

Prepared for:

100% Submission for

Fort McPherson VA Clinic Atlanta, GA

Revisions: Date:

l lllllll

OO OO O O ∅ ∅∅ ∅ ∅

' 6

G ra p h ic S ca le

/2

1'

-0

G ra p h ic S ca le

/3 2"

'-0

' G ra p h ic S ca le

/1 6"

'-0

' G ra p h ic

S ca le

/8

1' -0

G ra p h ic S ca le

/4

1'

-0

G ra p h ic S ca le

/8

1'

-0

' G ra p h ic

S ca le

/2

1' -0

G ra p h ic S ca le

/4

1'

-0

G ra p h ic S ca le

'-0

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

NOT FOR

PERMITTING OR

CONSTRUCTION

A/E:Consultant:

VISN 7 LIFE SAFETY SURVEY AND

DRAWING UPDATE, TASK ORDER

#13

GS-10F-0347P

Elijah Knight, PE

R R o m a n y k C o n s u lt in g \R

C C

A E

C

C o n s u lt in g \0

P ro je c ts

\V

IS

N

\L if e

S a fe ty \0

M o d e l\

A tl a n ta \B u ild in g s S u rv e y e d

\A T

-1

F o rt M c P h e rs o n

O P

C \A

T -1

F o rt

M c P h e rs o n O

P C

.r v t

/1

/2

:5

:2

A M

GENERAL SHEET

E.K. HP

G-04X1

VISN 7 ATLANTA

07/31/2018

VISN 7

ATLANTA

100% SUBMITTAL

Revisions: Date:

THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND

STAIRWELLS OF 4 OR MORE STORIES.

WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.

DUCTS: ALL DUCT PENETRATIONS ARE PROTECTED BY FIRE DAMPERS.

PENETRATIONS: ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP

MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL

PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE

WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON

THE TOP OF THE FLOOR.

DOORS: ALL DOORS REQUIRE THE FOLLOWING:

1. LABELED FRAMES (NFPA 80 4.2.1)

2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)

3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)

10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).

11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT AT

LEAST ANNUALLY (NFPA 80 5.2.4.1)

2-HOUR FIRE BARRIER

THIS APPLIES TO 1-HOUR FIRE RATED OCCUPANCY SEPERATIONS, HAZARDOUS ROOM

ENCLOSURES AND STAIRWELLS 3 STORIES OR LESS.

WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.

DUCTS: STEEL DUCT PENETRATIONS NOT REQUIRED TO BE PROTECTED BY

FIRE DAMPERS.

PENETRATIONS: ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP

MATERIALS FOR PROTECTING 1-HOUR WALL ASSEMBLIES. WALL

PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE

WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON

THE TOP OF THE FLOOR.

DOORS*: ALL DOORS REQUIRE THE FOLLOWING:

1. LABELED FRAMES (NFPA 80 4.2.1)

2. LABELED 3/4 OR 1-HOUR DOOR (NFPA 80 4.3.1)*

3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)

10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).

11.PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT

AT LEAST ANNUALLY (NFPA 80 5.2.4.1)

* 1-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 3

STORIES OR LESS.

1-HOUR FIRE BARRIER

WALL: IF THE HAZARDOUS ROOM HAS A SUSPENDED CEILING CONSTRUCTED

TO LIMIT TRANSFER OF SMOKE, THE WALL HAS NO FIRE RESISTANCE

RATING AND MAY TERMINATE AT THE CEILING. IF THE ROOM DOES NOT

HAVE A SUSPENDED CEILING, THE WALL HAS NO FIRE RESISTANCE

RATING AND SHALL EXTEND TO THE DECK ABOVE.

DUCTS: STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED

BY FIRE DAMPERS OR SMOKE DAMPERS.

PENETRATIONS: SEALED WITH NON-FIRE-RATED MATERIALS TO BE RESISTIVE. USE OF

LISTED FIRESTOP MATERIALS IS NOT REQUIRED.

DOORS: EXISTING HAZARDOUS ROOMS:

1. NON-LABELED FRAME (NFPA 101 19.3.7.9)

2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 19.3.7.6)

3. MAXIMUM 1296 SQ. IN. WINDOW (NFPA 101 19.3.6.3.17)

4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 19.3.6.3.5)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 19.3.2.1.3)

6. MAXIMUM 1/8" GAP (NFPA 101 19.3.6.3.1)

7. MAXIMUM 1" UNDERCUT (NFPA 101 19.3.6.3.4)

8. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 19.3.2.1.2)

9. SWING IN ANY DIRECTION

10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST

ANNUALLY (NFPA 105 5.2.1.1)

SMOKE RESISTIVE HAZARDOUS ROOMS

THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS

OF 4 OR MORE STORIES. THIS COMBINATION WALL IS WHERE A PORTION OF THE 2-HOUR

RATED WALL IS ALSO PART OF THE SMOKE WALL.

WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.

DUCTS: ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE

AND SMOKE DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED

WHERE ADJACENT SMOKE COMPARTMENTS ARE PROTECTED BY

QUICK RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.

PENETRATIONS: ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP

MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL

PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE

WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON

THE TOP OF THE FLOOR.

DOORS: ALL DOORS REQUIRE THE FOLLOWING:

1. LABELED FRAMES (NFPA 80 4.2.1)

2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)

3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)

4. POSITIVE LATCHING (NFPA 80 6.4.1.4)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)

6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)

7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)

8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)

9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)

10.SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).

11.PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT

AT LEAST ANNUALLY (NFPA 80 5.2.4.1)

2-HOUR FIRE AND SMOKE BARRIER

SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR

DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS OF

MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND THE

BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE

REQUIRED TO BE OF 1 HOUR FIRE RESISTANCE RATING. (NFPA 101, 18.3.2.7.5) SMOKE ZONE

BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED TO BE OF

A 1/2 HOUR FIRE RESISTANCE RATING (NFPA 101, 19.3.7.3)

WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.

DUCTS: ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE DAMPERS.

SMOKE DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE

COMPARTMENTS ARE PROTECTED BY QUICK RESPONSE SPRINKLERS

THROUGHOUT EACH COMPARTMENT.

PENETRATIONS: ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS

FOR PROTECTING 1-HOUR FIRE AND SMOKE WALL ASSEMBLIES.

PENETRATIONS ARE TO BE FILLED ON BOTH SIDES OF THE WALL.

DOORS: ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:

1. NON-LABELED FRAME (NFPA 101 18.3.7.6)

2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 18.3.7.6)

3. MAXIMUM 1296 SQ. IN. WINDOW (NFPA 80 4.4.4)

4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18.3.7.8)

5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18.3.7.8)

6. MAXIMUM 1/8" GAP (NFPA 101 18.3.7.6.)

7. MAXIMUM 1" UNDERCUT (NFPA 101 19.3.6.3.4)

8. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 18.3.7.6)

9. SWING IN DIRECTION OPPOSITE OF EACH OTHER (NFPA 101 18.3.7.6)

10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY

(NFPA 105 5.2.1.1)

SMOKE ZONE BARRIERS

IF THE SMOKE COMPARTMENT IS SPRINKLERED, THE WALL SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE. THE WALL HAS NO REQUIRED FIRE RESISTANCE RATING AND MAY TERMINATE AT A CEILING CONSTRUCTED TO LIMIT TRANSFER OF SMOKE. DOORS ARE MANUALLY CLOSED IN AN EMERGENCY NFPA 101, 18.3.6.2 & 19.3.6.2

IF THE SMOKE COMPARTMENT IS NOT SPRINKLERED, THE WALL SHALL BE CONTINUOUS FROM THE FLOOR TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK ABOVE. CORRIDOR WALL SHALL HAVE A MINIMUM 1/2 HOUR FIRE RESISTANCE RATING. DOORS ARE MANUALLY CLOSED IN AN EMERGENCY NFPA 101 19.3.6.2

DOORS: DOORS THAT ARE NOT PART OF A RATED WALL:

1. NON-LABELED FRAME (NFPA 101 18.3.6.3.1, 19.3.6.3 & 19.3.6.3.3)

2. NON-RATED DOORS PERMITTED IF SPRINKLERED (NFPA 101 18.3.6.3.1, 19.3.6.3.2(2))

3. 20-MINUTE OR SOLID WOOD CORE DOOR IF NOT SPRINKLERED (NFPA 101 19.3.6.3.1)

4. POSITIVE LATCHING EXCEPT TOILETS, SHOWER AND SINK

CLOSETS (NFPA 101 18.3.6.3.6 & 19.3.6.3.6)

5. SELF-CLOSING NOT REQUIRED (NFPA 101 19.3.6.3.11)

6. NO MAXIMUM GAP (NFPA 101 18.3.6.3.1 & 19.3.6.3.3)

7. MAXIMUM 1" UNDERCUT (NFPA 101 18.3.6.3.1 & 19.3.6.3.4)

8. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 18/19.3.6.3.12)

9. TRANSFER GRILLS NOT PERMITTED EXCEPT TOILETS, SHOWER AND SINK CLOSETS

(NFPA 101 18/19.3.6.4)

10. SWING IN ANY DIRECTION

11. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.1.1)

HEALTH CARE OCCUPANCY CORRIDORS

NOTE: ALL CODE REFERENCES ARE PER THE 2015 EDITION OF NFPA 101 LIFE SAFETY CODE AND THE OTHER APPLICABLE CODES. FEDERAL FACILITIES FOLLOW 2015 LIFE SAFETY CODE.

FORMER DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER ZONE.

BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY THE FIRE

DEPARTMENT PER SECTION 15.7.4.3 OF NFPA 99-2015 EDITION AND PRIVATE MODE AUDIBLE

REQUIREMENTS OF SECTION 18.4:4 OF NFPA 72-2016 EDITION.

WALL: WALL EXTENDS FROM FLOOR TO SUSPENDED CEILING OR DECK ABOVE.

DUCTS: NO MINIMUM REQUIREMENTS.

PENETRATIONS: NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A

SUSPENDED CEILING. PENETRATIONS BELOW A SUSPENDED CEILING

OR DECK SEALED WITH NON-FIRE-RATED MATERIALS TO BE SMOKE

RESISTIVE.

DOORS: NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC

CLOSING IN AN EMERGENCY.

NON-RATED SMOKE PARTITION

SUITES

HEALTHCARE AREA OPEN TO CORRIDOR WITH 24/7 SUPERVISION - NO SMOKE DETECTION REQUIRED.

HEALTHCARE AREA OPEN TO CORRIDOR - SMOKE DETECTION PROVIDED.

(COLOR #3) (COLOR #4) (COLOR #230)

(COLOR #1) (COLOR #6) (COLOR #30)

(COLOR #2)

(COLOR #2)

(COLOR #3)

' 6

G ra p h ic S ca le

/2

1'

-0

G ra p h ic S ca le

/3 2"

'-0

' G ra p h ic S ca le

/1 6"

'-0

' G ra p h ic

S ca le

/8

1' -0

G ra p h ic S ca le

/4

1'

-0

G ra p h ic S ca le

/8

1'

-0

' G ra p h ic

S ca le

/2

1' -0

G ra p h ic S ca le

/4

1'

-0

G ra p h ic S ca le

'-0

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

NOT FOR

PERMITTING OR

CONSTRUCTION

A/E:Consultant:

VISN 7 LIFE SAFETY SURVEY AND

DRAWING UPDATE, TASK ORDER

#13

GS-10F-0347P

Elijah Knight, PE

R R o m a n y k C o n s u lt in g \R

C C

A E

C

C o n s u lt in g \0

P ro je c ts

\V

IS

N

\L if e

S a fe ty \0

M o d e l\

A tl a n ta \B u ild in g s S u rv e y e d

\A T

-1

F o rt M c P h e rs o n

O P

C \A

T -1

F o rt

M c P h e rs o n O

P C

.r v t

/1

/2

:5

:2

A M

GENERAL SHEET

E.K. HP

G-04X2

VISN 7 ATLANTA

07/31/2018

VISN 7

ATLANTA

100% SUBMITTAL

Revisions: Date:

APPLICABLE CODES AND STANDARDS:

1. THE BUILDING WAS DESIGNED TO THE 1960 EDITION OF NFPA 101, LIFE SAFETY CODE.

2. THE 1960 PUBLIC BUILDING AMENDMENT ACT (PL100-678) REQUIRES ALL FEDERAL AGENCIES TO FOLLOW

THE LATEST EDITIONS OF NATIONALLY RECOGNIZED FIRE AND LIFE SAFETY CODES. THE VA HAS ADOPTED THE NATIONAL FIRE CODES PUBLISHED BY THE NATIONAL FIRE PROTECTION ASSOCIATION. LIFE SAFETY REQUIREMENTS ARE SPECIFICALLY ADDRESSED IN THE 2018 EDITION OF NFPA 101, LIFE SAFETY CODE.

3. ALL NEW CONSTRUCTION OR BUILDING RENOVATIONS ARE REQUIRED TO COMPLY WITH THE LATEST EDITION OF NFPA 101 OR IT'S REFERENCED STANDARDS. EXISTING BUILDING CONDITIONS ARE REQUIRED TO COMPLY WITH THE APPLICABLE CODES OR STANDARDS AT THE TIME OF BUILDING DESIGN AND THE APPLICABLE PROVISIONS FOR EXISTING BUILDINGS IN CURRENT EDITIONS OF APPLICABLE

CODES AND STANDARDS.

4. OTHER NFPA CODES AND STANDARDS:

A. NFPA 10 - PORTABLE FIRE EXTINGUISHERS, 2018 EDITION.

B. NFPA 13 - SPRINKLER SYSTEMS, 2016 EDITION.

C. NFPA 14 - STANDPIPE SYSTEMS, 2016 EDITION.

D. NFPA 20 - FIRE PUMPS, 2016 EDITION

E. NFPA 70 - NATIONAL ELECTRIC CODE, 2017 EDITION.

F. NFPA 72 - NATIONAL FIRE ALARM CODE, 2016 EDITION.

G. NFPA 75 - ELECTRONIC COMPUTER EQUIPMENT, 2017 EDITION.

H. NFPA 80 - FIRE DOORS, 2016 EDITION.

I. NFPA 90A&B - HEATING AND AIR CONDITIONING SYSTEMS, 2018 EDITION.

J. NFPA 96 - COMMERCIAL COOKING EQUIPMENT, 2017 EDITION.

K. NFPA 99 - HEALTH CARE FACILITIES CODE, 2018 EDITION.

L. NFPA 105 - SMOKE DOORS, 2016 EDITION.

M. NFPA 110 - EMERGENCY POWER SYSTEMS, 2016 EDITION.

N. NFPA 241 - CONSTITUTION AND DEMOLITION, 2013 EDITION.

PENETRATIONS:

1. PRIOR TO THE EARLY 1990'S, THE STANDARD INDUSTRY PRACTICE FOR THE SEALING OF PENETRATIONS WAS TO

USE THE SAME CONSTRUCTION MATERIALS AS HOW THE WALL/FLOOR WAS CONSTRUCTED. CONCRETE PATCH WAS USED FOR CONCRETE FLOORS. MORTAR JOINT COMPOUND WAS USED FOR MASONRY WALLS. GYPSUM

PATCH COMPOUND WAS USED USED FOR GYPSUM WALLS.

2. PRIOR TO THE EARLY 1990'S, THE MANUFACTURES PUBLISHED INSTRUCTIONS FOR FIRE RESISTIVE WALL AND FLOOD CONSTRUCTION REQUIRED THE USE OF THE SAME CONSTRUCTION MATERIALS AS HOW THE WALL/FLOOR

WAS CONSTRUCTED TO SEAL PENETRATIONS.

3. THE FIRST LISTINGS OF FIRESTOP MATERIALS WAS IN 1991. THE FIRST CODE REQUIREMENTS TO UTILIZE LISTED

FIRESTOP MATERIALS OCCURRED IN 1992 EDITIONS OF CODES AND STANDARDS.

4. ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR PROTECTING THE REQUIRED RATING

OF THE WALL ASSEMBLY.

5. EXISTING PENETRATIONS SEALED WITH THE SAME CONSTRUCTION MATERIAL AS THE WALL/FLOOR, MAY REMAIN

AS AN EXISTING PREVIOUSLY APPROVED CONSTRUCTION METHOD.

6. EXISTING PENETRATIONS THAT REQUIRE REPAIR OR REPLACEMENT REQUIRE THE USE OF LISTED FIRESTOP

MATERIALS.

FIRE SPRINKLER SYSTEM:

1. THE COMBINATION STANDPIPE AND FIRE SPRINKLER SYSTEM WAS DESIGNED TO THE 2016 EDITION OF NFPA 13.

2. QUICK RESPONSE TYPE SPRINKLERS ARE INSTALLED THROUGHOUT MOST OF THE BUILDING. STANDARD

RESPONSE TYPE SPRINKLERS ARE INSTALLED IN THE ELEVATOR MACHINE ROOMS.

3. SPRINKLERS WERE INSTALLED IN LIGHT HAZARD AREAS INCLUDING; CORRIDORS, OFFICES, PATIENT CARE AND

PATIENT SLEEPING ROOMS AT LIGHT HAZARD 0.10 GPM/1500 SQ. FT. DENSITY.

4. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP I AREAS INCLUDING; LABORATORIES (WITHOUT

FLAMMABLE LIQUIDS), MECHANICAL EQUIPMENT ROOMS, ELECTRICAL SWITCH GEAR ROOMS, REPAIR SHOPS AND

STORAGE ROOMS UNDER 250 SQ. FT. AT A 0.15 GPM/1500 SQ. FT. DENSITY.

5. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP II AREAS INCLUDING GENERAL STORAGE ROOMS OVER 250 SQ. FT. AND LABORATORIES (WITH THE USE OF FLAMMABLE LIQUIDS) AT A 0.20 GPM/1500 SQ. FT.

DENSITY.

FIRE ALARM SYSTEM:

1. THE FIRE ALARM SYSTEM WAS DESIGNED TO THE 2013 EDITION OF NFPA 72, NATIONAL FIRE ALARM CODE.

2. PRIVATE MODE BUILDING OCCUPANT NOTIFICATION IS INSTALLED PER SECTIONS 19.3.4.3.1 AND 9.6.3.6.3 OF NFPA

101-2015 EDITION.

3. PRIVATE MODE AUDIBLE DEVICES (SPEAKERS) ARE INSTALLED IN CORRIDORS AND LARGER ROOMS OR SUITES

PER SECTION 18.4.4.1 OF NFPA 72-2016 EDITION.

4. PRIVATE MODE VISIBLE DEVICES (STROBES) ARE INSTALLED AT REDUCED QUANTITY AND SPACING PER SECTION

18.6 OF THE NFPA 72-2016 EDITION.

5. STROBE CIRCUITS ARE REQUIRED TO BE SYNCHRONIZED IN ACCORDANCE WITH SECTION 18.5.5.4.2 OF NFPA

72-2016 EDITION.

SUITES:

1. SUITES ARE UTILIZED TO ILLUSTRATE AREAS WITH THE SAME FUNCTION, USE OF HALLWAYS OR AISLES AND THE

END OF PUBLIC EXIT CORRIDORS. NO EXIT SIGNS OUTSIDE OF THE SUITE DIRECT OCCUPANTS INTO A SUITE TO

REACH AN EXIT.

2. HEALTH CARE OCCUPANCY SUITES ARE REGULATED BY FUNCTION AND SIZE.

3. HEALTH CARE OCCUPANCY PATIENT SLEEPING SUITES:

A. SINGLE EXIT SUITE - 1,000 SQ. FT. (NFPA 101 -19.2.5.7.2.2)

B. MULTI EXIT SUITE - 5,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.A)

C. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS OR COMPLETE SMOKE DETECTION - 7,500 SQ.

FT. (NFPA 101 - 19.2.5.7.2.3.B)

D. MULTI EXIT SUITE WITH DIRECT VISUAL SUPERVISION, QUICK RESPONSE SPRINKLERS AND COMPLETE

SMOKE DETECTION - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.C)

4. PATIENT CARE NON - SLEEPING SUITES:

A. SINGLE EXIT SUITE - 2,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.1.B)

B. MULTI EXIT SUITE - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.3.2)

C. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS AND COMPLETE SMOKE DETECTION OR QUICK

RESPONSE SPRINKLERS - 12,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.2.A)

D. MULTI EXIT SUITE WITH QUICK RESPONSE SPRINKLERS AND COMPLETE SMOKE DETECTION (NFPA 101 -

19.2.5.7.3.2.B)

5. HEALTH CARE OCCUPANCY NON - PATIENT - CARE SUITES FOLLOW THE TRAVEL DISTANCE REQUIREMENTS

AS LISTED IN TABLE A.7.6 OF NFPA 101.

6. SUITES IN OTHER OCCUPANCIES ARE NOT REGULATED IN SIZE BUT STILL FOLLOW THE TRAVEL DISTANCE

REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.

BUILDING # FLOOR

HEALTH CARE

OCCUPANCY

TOTAL

508C 1 49,031 0 22,513 0 71,544

AMBULATORY HEALTH

CARE OCCUPANCY

BUSINESS

OCCUPANCY

INDUSTRIAL

OCCUPANCY

508ASCA 2 0 0 56,228 0 56,228

508ASCA 1 0 0 56,573 0 56,573

125 2 0 0 22,258 0 22,258

125 1 0 0 41,126 0 41,126

128 2 0 0 8,723 0 8,723

128 1 0 0 8,723 0 8,723

SUB TOTAL 0 0 17,446 0 17,446

129 2 0 0 8,696 0 8,696

129 1 0 0 8,692 0 8,692

SUB TOTAL 0 0 17,388 0 17,388

130 1 0 0 8,721 0 8,721

131 2 0 0 0 0 9,517

SUB TOTAL 0 0 8,721 0 17,442

131 GROUND 0 0 9,516 0 9,516

SUB TOTAL 0 0 9,516 0 28,551

GRAND TOTAL 49,031 0 263,657 0 340,444

OCCUPANCY TABLE

DORMITORY

OCCUPANCY

9,517

8,721

19,035

27,756

SUB TOTAL

SUB TOTAL 0 0 112,801 0 112,8010

125 BASEMENT 0 0 11,888 0 11,8880

SUB TOTAL 0 0 75,272 0 75,2720

130 2 0 0 0 0 8,7218,721

131 1 0 0 0 0 9,5189,518

49,031 0 22,513 0 71,5440

LEGEND

l lllllll

O OO

OO OO

KEY NOTES

KEY NOTES

l llll l l l l l l l l ll llll l l l l l l l l l l l l l lllllllllllllll l l l l l l l l l l l l l l l l l l ll l l l l l l l ll llll l l l l l l l l l l llll l l l l l ll lll

DOOR FAILS INSPECTION TEST

DOOR PASSES INSPECTION TEST

FB1 = FIRE BARRIER 1HR

FB2 = FIRE BARRIER 2HR

FB1/2 = FIRE BARRIER 30 MIN

FSB1 = FIRE / SMOKE BARRIER 1HR

FSB2 = FIRE / SMOKE BARRIER 2HR

SP0 = SMOKE PARTITION NON-RATED

SB0 = SMOKE BARRIER NON-RATED

EHR = EXISTING HAZARDOUS ROOMS

HCO = HEALTH CARE OCCUPANCY

NON-RATED

NON-RATED INTERIOR PARTITION WALL

XXX-XXXX-XX-XXXXX DOOR TAG

105 SF

STOR

BA002

101 SF

OFFICE

BA003

856 SF

MECH RM.

BA004

106 SF

SUPER. OFF

BA005

111 SF

COMM.

BA006

195 SF

ELEC RM.

BA007

150 SF

BREAK RM

BA008

688 SF

COMMON SHOP

BA009

103 SF

UPS

BA010

97 SF

PARTS

BA011

202 SF

OFFICE

BA012

97 SF

FORMS & FILES

BA014

102 SF

STORAGE

BA015

101 SF

CHIEF LOGISTICS

BA016

100 SF

UNISEX TLT

BA01799 SF

MTF FORM STOR

BA018

50 SF

FEMALE TLT

BA019

99 SF

MAIL

BA020

50 SF

MALE TLT

BA021

255 SF

NOT KNOWN

BA023

278 SF

LOADING DOCK

/ RECEIVING /

PROCESSING

BA024

58 SF

HOLDING

WASTE

BA025

238 SF

EMS STORAGE

BA026

236 SF

OIT STORAGE

BA027

111 SF

OFFICE

BA028

107 SF

OFFICE

BA029

149 SF

NOT KNOWN

BA030

472 SF

ENGINEERING

BA031

791 SF

CALL CENTER -

OFF SPACE

BA032

97 SF

NOT KNOWN

BA034

475 SF

COMPUTER RM

BA036

73 SF

ELEV. MACH.

RM.

BA001

106 SF

NOT KNOWN

BA03

173 SF

SOILED LINEN

BA022

73 SF

CYLINDER

HOLDING

BA037

495 SF

MEDICAL GAS EQUIP

BA038

707 SF

CORR

BA041

222 SF

CORR

BA040 61 SF

ELEV.

EB-NO. 3

138 SF

STAIR

SB-NO. 4

235 SF

CORR

BA042

390 SF

CORR

BA043

235 SF

CORR

RCCB01R

537 SF

CALL CENTER

RCCB02R

135 SF

STAIR

SB-NO. 2

FLAMMABLE

HAZARDOUS

STG.

AREAWAY

508-125-0B-DRF001

508-125-0B-DRF002

508-125-0B-DRF003

508-125-0B-DRF004

508-125-0B-DRS001

508-125-0B-DRS002

508-125-0B-DRS004

508-125-0B-DRS003

508-125-0B-DRS005

' 6

G ra p h ic S ca le

/2

1'

-0

G ra p h ic S ca le

/3 2"

'-0

' G ra p h ic S ca le

/1 6"

'-0

' G ra p h ic

S ca le

/8

1' -0

G ra p h ic S ca le

/4

1'

-0

G ra p h ic S ca le

/8

1'

-0

' G ra p h ic

S ca le

/2

1' -0

G ra p h ic S ca le

/4

1'

-0

G ra p h ic S ca le

'-0

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

NOT FOR

PERMITTING OR

CONSTRUCTION

A/E:Consultant:

VISN 7 LIFE SAFETY SURVEY AND

DRAWING UPDATE, TASK ORDER

#13

GS-10F-0347P

Elijah Knight, PE

R R o m a n y k C o n s u lt in g \R

C C

A E

C

C o n s u lt in g \0

P ro je c ts

\V

IS

N

\L if e

S a fe ty \0

M o d e l\

A tl a n ta \B u ild in g s S u rv e y e d

\A T

-1

F o rt M c P h e rs o n

O P

C \A

T -1

F o rt

M c P h e rs o n O

P C

.r v t

/1

/2

:5

:2

A M

FIRE/SMOKE DOOR INSPECTION FLOOR PLAN -

BASEMENT

E.K. HP

LS040B

VISN 7 ATLANTA

07/31/2018

VISN 7

ATLANTA

100% SUBMITTAL

Note Number Fire Door Note

1 VISIBLE SIGN OF DAMAGE

2 PARTS MISSING OR BROKEN

3 SURFACE HOLES IN DOOR OR FRAME

4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE

4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE

5 FAILED GLAZING AND FRAME INSPECTION

6 SELF-CLOSING DEVICE NOT OPERATIONAL

7 COORDINATOR NOT OPERATIONAL

8 LATCHING HARDWARE NOT OPERATIONAL

9 AUXILIARY HARDWARE INTERFERENCE

10 EDGE CLEARANCE NOT ACCEPTABLE

11 DOOR CLEARANCE NOT ACCEPTABLE

12 SIGNAGE DOES NOT MEET REQUIREMENTS

13 FIELD MODIFICATIONS VOID LABEL

Note Number Fire Smoke Door Note

1 VISIBLE SIGN OF DAMAGE

2 PARTS MISSING OR BROKEN

3 SURFACE HOLES IN DOOR OR FRAME

4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE

4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE

5 FAILED METAL DOOR FRAME INSPECTION

6 FAILDED GLAZING AND FRAME INSPECTION

7 SELF-CLOSING DEVICE NOT OPERATIONAL

8 COORDINATOR NOT OPERATIONAL

9 LATCHING HARDWARE NOT OPERATIONAL

10 AUXILIARY HARDWARE INTERFERENCE

11 EDGE CLEARANCE NOT ACCEPTABLE

12 DOOR CLEARANCE NOT ACCEPTABLE

NORTH ARROW

FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - BASEMENT

3/32" = 1'-0" l lllllll

O OO

OO OO

KEY NOTES

KEY NOTES

l llll l l l l l ll lll l l l l l l l l l ll l l l l l l l l l l ll lll l ll l l l l l l l l l llll l lllll l l l l l ll lllll l l l l

DOOR FAILS INSPECTION TEST

DOOR PASSES INSPECTION TEST

FB1 = FIRE BARRIER 1HR

FB2 = FIRE BARRIER 2HR

FB1/2 = FIRE BARRIER 30 MIN

FSB1 = FIRE / SMOKE BARRIER 1HR

FSB2 = FIRE / SMOKE BARRIER 2HR

SP0 = SMOKE PARTITION NON-RATED

SB0 = SMOKE BARRIER NON-RATED

EHR = EXISTING HAZARDOUS ROOMS

HCO = HEALTH CARE OCCUPANCY

NON-RATED

NON-RATED INTERIOR PARTITION WALL

XXX-XXXX-XX-XXXXX DOOR TAG

480 SF

WAIT

1A400

193 SF

RECEPTION

1A401

99 SF

PUB MALE TLT

1A402

101 SF

PULIC FEMALE

TLT

1A403

69 SF

J.C.

1A404

100 SF

EXAM RM 1

1A405

100 SF

EXAM RM 3

1A406

101 SF

PHYS. OFF. 1

1A407

101 SF

PHYS. OFF. 2

1A408

100 SF

EXAM RM 2

1A409

100 SF

EXAM RM 4

1A410

157 SF

TREAT. RM.

1A411

86 SF

SOILED UTIL

1A412

99 SF

NRS OFF

1A413

100 SF

EXAM RM 5

1A414

100 SF

EXAM RM 7

1A415

101 SF

PHYS. OFF. 3

1A416

99 SF

PHYS. OFF. 4

1A417

100 SF

EXAM RM 6

1A418

99 SF

EXAM RM 8

1A419

208 SF

WAIT (SPECIALTY CLINIC)

1A420

147 SF

STAIR

S1-NO. 1

79 SF

SCRN. RM. 4

1A421

79 SF

SCRN. RM. 3

1A422

80 SF

SCRN. RM. 2

1A423

77 SF

SCRN. RM. 1

1A424

229 SF

OFFICE

1A425

100 SF

EXAM RM 12

1A426

47 SF

ISO. TLT

1A427

100 SF

EXAM RM 10

1A428

100 SF

CHIEF OFF

1A429

100 SF

DR. OFF 5

1A430

100 SF

EXAM RM 11

1A431

100 SF

EXAM RM 9

1A432

100 SF

EXAM RM 6

1A433

99 SF

DR. OFF 3

1A434

95 SF

EXAM RM 5

1A435

100 SF

EXAM RM 8

1A436

100 SF

EXAM RM 4

1A437

100 SF

DR. OFF 4

1A438

101 SF

DR. OFF 2

1A439

100 SF

EXAM RM 7

1A440

100 SF

EXAM RM 3

1A441

101 SF

NRS OFF 2

1A442 74 SF

SOILED UTIL

1A443

100 SF

EXAM RM 2

1A444

149 SF

OMNI CELL

1A445

101 SF

SPINAL

1A446

102 SF

SPINAL

1A447

100 SF

EXAM RM 1

1A448

134 SF

BREAK RM

1A449

311 SF

GROUP

1A450

AREAWAY

126 SF

STAFF MALE

TLT/LKR

1A451

127 SF

STAFF FEMALE

TLT/LKR

1A452

60 SF

COMM.

1A453

73 SF

ELEC.

1A454

109 SF

LOUNGE

1A455

91 SF

NCOIC

1A456

167 SF

SECTY./CLER. OFF

1A457

2,275 SF

CORR

RCC101R

261 SF

CORR

RCC102R

89 SF

WAIT

1A100

155 SF

ADMIN. OFF

1A101

182 SF

RECEPTION

1A103

44 SF

SPEC. TLT.

1A104

110 SF

AUDIO RM.

1A105

90 SF

VISION HGT. &

WGT.

1A106

109 SF

NRS OFF 3

1A107

116 SF

NCOIC

1A108

106 SF

OFFICE

1A109

288 SF

CONFERENCE

1A110

460 SF

NOT KNOWN

1A111

92 SF

IMMUN. RM.

1A112

96 SF

IMMUN. HOLD

1A113

99 SF

NRS OFF 2

1A114

84 SF

SCRN. RM. 3

1A115

100 SF

EXAM RM 9

1A116 118 SF

EXAM RM 11

1A117

101 SF

CHIEF OFF

1A118 66 SF

EXAM

1A119

101 SF

EXAM RM 10

1A120

100 SF

EXAM RM 12

1A121

80 SF

SCRN. RM. 2

1A122

83 SF

SCRN. RM. 1

1A123

85 SF

SUB-WAIT

1A124

100 SF

EXAM RM 5

1A125

100 SF

EXAM RM 7

1A126

101 SF

DR. OFF 3

1A127

99 SF

DR. OFF 4

1A128

100 SF

EXAM RM 6

1A129

97 SF

EXAM RM 8

1A130

83 SF

NOT KNOWN

1A131

120 SF

NRS OFF 1

1A132

101 SF

EXAM RM 1

1A133

100 SF

EXAM RM 3

1A134

101 SF

DR. OFF 1

1A135 101 SF

DR. OFF 2

1A136

101 SF

EXAM RM 2

1A137

100 SF

EXAM RM 4

1A138

91 SF

STAFF FEMALE

LKR

1A139

91 SF

STAFF FEMALE

TLT

1A140

100 SF

STAFF MALE TLT

1A141

118 SF

LOUNGE

1A142

86 SF

EXAM

1A143 173 SF

OFFICE

1A144

54 SF

STAFF

1A145

73 SF

OMNI CELL

1A146

420 SF

GROUP RM

1A147

103 SF

CRASH CART

1A148

66 SF

EXAM

1A149

67 SF

TLT

1A150

86 SF

PUB FEMALE

TLT

1A151

86 SF

PUB MALE

TOILET

1A152

70 SF

ELEC.

1A153

68 SF

COMM.

1A154

50 SF

J.C.

1A155

1,376 SF

CORR

RCC103R

523 SF

CORR

RCC104R

135 SF

STAIR

S1-NO. 2

67 SF

ELEV. MACH.

RM.

1A201

259 SF

NOT KNOWN

1A202

214 SF

COFFEE SHOP

1A203

789 SF

NOT KNOWN

1A204

103 SF

NOT KNOWN

1A205

103 SF

FEMALE TLT

1A206

186 SF

NOT KNOWN

1A207

121 SF

CHAMPUS

1A208

121 SF

PAT. ADVOC.

1A209

438 SF

WAIT

1A210

42 SF

NOT KNOWN

1A211

477 SF

WAITING

1A212

86 SF

TRASH

1A213

68 SF

SOILED UTILITY

1A214

53 SF

STAFF TLT

1A215

91 SF

OFFICE

1A216

94 SF

EXAM

1A217

102 SF

OFFICE

1A218

110 SF

EXAM

1A219

108 SF

OFFICE

1A220

85 SF

OFFICE

1A221

89 SF

OFFICE

1A222

95 SF

EXAM

1A223

96 SF

EXAM

1A224

111 SF

EXAM

1A225

112 SF

NOT KNOWN

1A226

323 SF

RECEPTION

1A227

331 SF

CLASS RM

1A228

200 SF

WAIT

1A229

326 SF

RADIOGRAPH / FLURO

1A230

110 SF

STAIR

S1-NO. 4

57 SF

ELEV.

E1-NO. 3

919 SF

CORR

RCC105R

49 SF

PUB TLT

1A235

260 SF

MAMMO. RM.

1A236

297 SF

RADIOGRAPH

1A237

40 SF

SPINAL

1A238

38 SF

SPINAL

1A239

12 SF

LINEN

1A240

23 SF

J.C.

1A241

90 SF

LOCK.

1A242

80 SF

TLT

1A243

95 SF

OFFICE

1A244

87 SF

STOR

1A245

120 SF

OFFICE

1A246

128 SF

OFFICE

1A247

99 SF

OFFICE

1A248

429 SF

CONFERENCE

RCC106R

106 SF

RECEPTION

RCC107R

52 SF

PAT TLT

RCC108R

575 SF

CORR

RCC109R

210 SF

CORR

RCC110R

40 SF

DRESS. 4

RCC111R

39 SF

DRESS. 3

RCC112R

48 SF

WAIT

RCC113R

776 SF

MFG/PRE PACK / DISPENSING /

BULK STOR.

1A300

193 SF

NOT KNOWN

1A301

43 SF

POISON

1A302

41 SF

NOT KNOWN

1A303

76 SF

DISPATCH

1A304

83 SF

CNTR. DRUG

1A305

100 SF

LOCK.

1A306

52 SF

NOT KNOWN

1A307

45 SF

NOT KNOWN

1A308

101 SF

CHIEF

1A309

45 SF

J.C.

1A310

151 SF

OFFICE

1A311

100 SF

THERAPIST

1A313

100 SF

EXAM

1A315

142 SF

OFFICE

1A317

67 SF

MALE TLT /

SHWR

1A320

19 SF

LINEN

1A319

67 SF

FEMALE

TLT/SHWR

1A318

98 SF

NOT KNOWN

1A323

105 SF

NOT KNOWN

1A324

79 SF

OFFICE

1A325

60 SF

J.C.

1A326

119 SF

WRK. STA.

1A327

625 SF

MECH RM.

1A329

283 SF

CORR

RCC114R

51 SF

ELEC.

RCC115R

766 SF

CORR

RCC116R

138 SF

CORR

RCC117R

58 SF

ELEV.

(PASSENGER)

E1-NO. 1

58 SF

ELEV.

(PASSENGER)

(ADD. NO. 4)

E1-NO. 2

72 SF

STAIR

S1-NO. 3

27 SF

VENDING AREA

RCC118R

493 SF

MAIN LOBBY

1A200

918 SF

CORR

RCC119R

27 SF

TEL. AREA

RCC120R

1,158 SF

CORR

RCC121R

144 SF

VEST

RCC122R

462 SF

CORR

RCC123R

468 SF

CORR

RCC124R199 SF

CORR

RCC125R

77 SF

1A321

80 SF

1A314

89 SF

1A322

82 SF

1A316

26 SF

3A117

508-125-01-DRF001

508-125-01-DRF002

508-125-01-DRF003

508-125-01-DRS001

508-125-01-DRS002

508-125-01-DRS003

508-125-01-DRS004

508-125-01-DRS005

' 6

G ra p h ic S ca le

/2

1'

-0

G ra p h ic S ca le

/3 2"

'-0

' G ra p h ic S ca le

/1 6"

'-0

' G ra p h ic

S ca le

/8

1' -0

G ra p h ic S ca le

/4

1'

-0

G ra p h ic S ca le

/8

1'

-0

' G ra p h ic

S ca le

/2

1' -0

G ra p h ic S ca le

/4

1'

-0

G ra p h ic S ca le

'-0

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

NOT FOR

PERMITTING OR

CONSTRUCTION

A/E:Consultant:

VISN 7 LIFE SAFETY SURVEY AND

DRAWING UPDATE, TASK ORDER

#13

GS-10F-0347P

Elijah Knight, PE

R R o m a n y k C o n s u lt in g \R

C C

A E

C

C o n s u lt in g \0

P ro je c ts

\V

IS

N

\L if e

S a fe ty \0

M o d e l\

A tl a n ta \B u ild in g s S u rv e y e d

\A T

-1

F o rt M c P h e rs o n

O P

C \A

T -1

F o rt

M c P h e rs o n O

P C

.r v t

/1

/2

:5

:2

A M

FIRE/SMOKE DOOR INSPECTION FLOOR PLAN -

LEVEL 01

E.K. HP

LS0401

VISN 7 ATLANTA

07/31/2018

VISN 7

ATLANTA

100% SUBMITTAL

Note Number Fire Door Note

1 VISIBLE SIGN OF DAMAGE

2 PARTS MISSING OR BROKEN

3 SURFACE HOLES IN DOOR OR FRAME

4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE

4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE

5 FAILED GLAZING AND FRAME INSPECTION

6 SELF-CLOSING DEVICE NOT OPERATIONAL

7 COORDINATOR NOT OPERATIONAL

8 LATCHING HARDWARE NOT OPERATIONAL

9 AUXILIARY HARDWARE INTERFERENCE

10 EDGE CLEARANCE NOT ACCEPTABLE

11 DOOR CLEARANCE NOT ACCEPTABLE

12 SIGNAGE DOES NOT MEET REQUIREMENTS

13 FIELD MODIFICATIONS VOID LABEL

Note Number Fire Smoke Door Note

1 VISIBLE SIGN OF DAMAGE

2 PARTS MISSING OR BROKEN

3 SURFACE HOLES IN DOOR OR FRAME

4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE

4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE

5 FAILED METAL DOOR FRAME INSPECTION

6 FAILDED GLAZING AND FRAME INSPECTION

7 SELF-CLOSING DEVICE NOT OPERATIONAL

8 COORDINATOR NOT OPERATIONAL

9 LATCHING HARDWARE NOT OPERATIONAL

10 AUXILIARY HARDWARE INTERFERENCE

11 EDGE CLEARANCE NOT ACCEPTABLE

12 DOOR CLEARANCE NOT ACCEPTABLE

NORTH ARROW

FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 01

3/32" = 1'-0" l lllllll

O OO

OO OO

KEY NOTES

KEY NOTES

ll llll l l l l l l l l l l l l l lllllllllll l l l l l l l l ll llll l l l l l ll ll l l l l l l l l l l l l l l l l l l l l l l l l l l l l l ll ll l ll ll l llll l l l l l ll llll l l l l

DOOR FAILS INSPECTION TEST

DOOR PASSES INSPECTION TEST

FB1 = FIRE BARRIER 1HR

FB2 = FIRE BARRIER 2HR

FB1/2 = FIRE BARRIER 30 MIN

FSB1 = FIRE / SMOKE BARRIER 1HR

FSB2 = FIRE / SMOKE BARRIER 2HR

SP0 = SMOKE PARTITION NON-RATED

SB0 = SMOKE BARRIER NON-RATED

EHR = EXISTING HAZARDOUS ROOMS

HCO = HEALTH CARE OCCUPANCY

NON-RATED

NON-RATED INTERIOR PARTITION WALL

XXX-XXXX-XX-XXXXX DOOR TAG

97 SF

FIT & DISP.

2A300

288 SF

NOT KNOWN

2A301

129 SF

EYE EXAM

2A302

82 SF

MED

2A303

65 SF

ELEC.

2A304

68 SF

COMM.

2A305

290 SF

GROUP RM

2A306

129 SF

SCREEN

2A307

216 SF

WATER LAB

2A308

98 SF

EXAM RM 1

2A309

104 SF

DOCTOR'S OFF

2A310

349 SF

GROUP RM

2A311

100 SF

EXAM RM 2

2A312

152 SF

PVT MED SPEC

OFF

2A313

100 SF

CHIEF OFF

2A314

100 SF

COMM. NRS

2A315

103 SF

OCCUP. NRS 1

2A316

63 SF

MALE TLT

2A317

102 SF

OCCUP. NRS 2

2A318

63 SF

FEMALE TLT

2A319

102 SF

OCCUP. NRS 3

2A320

99 SF

NCOIC

2A322

120 SF

SEC

2A323

244 SF

CONF

2A324

140 SF

CHIEF NRS

2A325

99 SF

CHIEF WARD

MASTER

2A326

135 SF

DCCS OFF

2A327

135 SF

DEPT. CDR

2A328

93 SF

FEMALE TLT

2A329

180 SF

SEC

2A330

118 SF

MALE TLT

2A331

182 SF

SEC

2A332

163 SF

COMMAND OFF

2A333

27 SF

STG

2A334

112 SF

NCO

2A335

136 SF

MULTI-OFF

2A336

300 SF

COMP RM

2A337

158 SF

MULTI-OFF

2A338

153 SF

STAIR

S2-NO. 1

482 SF

INTERVIEW/FILES

2A339

69 SF

NOT KNOWN

RCC201R

574 SF

CORR

RCC202R

688 SF

CORR

RCC203R

OPEN

TO

BELOW

1,089 SF

MECH RM.

2A000

ROOF BELOW

78 SF

ELEV. (FREIGHT)

E2-NO. 3

712 SF

MECH RM.

2A201

300 SF

CORR

RCC204R

58 SF

ELEV.

(PASSENGER)

E2-NO. 1

58 SF

ELEV.

(PASSENGER)

(ADD. NO. 4)

E2-NO. 2

1,033 SF

CORR

RCC205R

145 SF

STAIR

S2-NO. 3

1,036 SF

MECH RM.

2A200

233 SF

OFFICE

2A100

120 SF

NCOIC

2A101

117 SF

SEC

2A102

203 SF

RECEPTION

2A103

50 SF

FILES

2A104

164 SF

CHIEF, DENTAL

2A105

129 SF

CLERIC

2A106

120 SF

DTR/OTH 14

2A107

120 SF

DTR/OTH 13

2A108

121 SF

DTR/OTH 12

2A109

92 SF

STG

2A110

122 SF

DTR/OTH 11

2A111

355 SF

WAIT

2A112

162 SF

CONSULTATION 3

2A113

122 SF

DTR/OTH 10

2A114

152 SF

X-RAY

2A115

88 SF

STG

2A116

68 SF

DEVEL.

2A117

122 SF

DTR/OTH 9

2A118

92 SF

CLEAN SUPPLY

2A119

121 SF

DTR/OTH 8

2A120

121 SF

DTR 6

2A121

122 SF

DTR/OTH 7

2A122

121 SF

DTR 5

2A123

38 SF

J.C. & SUPP

2A124

158 SF

CONSULTATION 2

2A125135 SF

STAIR

S2-NO. 2

113 SF

DENTAL LOUNGE

2A126

31 SF

DRUG STOR.

2A127

31 SF

CYL. STOR.

2A128

144 SF

STAFF MALE

TLT/LKR

2A129

155 SF

CENTRAL STER.

2A130161 SF

STAFF FEMALE

TLT/LKR

2A131

273 SF

LMT PROS/DENT.

2A132

121 SF

DTR/OTH 4

2A133

120 SF

DTR/OTH 3

2A134

181 SF

CONSULTATION 1

2A135

161 SF

DECONTAM.

2A136

97 SF

STOR

2A138

129 SF

CENTRAL ISSUE

2A139

91 SF

CLEAN SUPPLY

2A140

116 SF

DTR/OTH 2

2A141

117 SF

DTR/OTH 1

2A142

82 SF

MALE PAT

TOILET

2A143

87 SF

FEMALE PAT

TOILET

2A144

82 SF

ELEC.

2A145

77 SF

COMM.

2A146

1,234 SF

CORR

RCC206R

262 SF

WAITING

RCC207R

508-125-02-DRF001

508-125-02-DRF002

508-125-02-DRS001

508-125-02-DRS002 508-125-02-DRS003

508-125-02-DRS004

508-125-02-DRS005 508-125-02-DRS006

4b

11 7

' 6

G ra p h ic S ca le

/2

1'

-0

G ra p h ic S ca le

/3 2"

'-0

' G ra p h ic S ca le

/1 6"

'-0

' G ra p h ic

S ca le

/8

1' -0

G ra p h ic S ca le

/4

1'

-0

G ra p h ic S ca le

/8

1'

-0

' G ra p h ic

S ca le

/2

1' -0

G ra p h ic S ca le

/4

1'

-0

G ra p h ic S ca le

'-0

Romanyk Consulting Focusing on what matters

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

F

U.S. Department of Veterans Affairs

E

D

C

B

A

F

E

D

C

B

A

910 7 6 5 4 3 2 1

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093

NOT FOR

PERMITTING OR

CONSTRUCTION

A/E:Consultant:

VISN 7 LIFE SAFETY SURVEY AND

DRAWING UPDATE, TASK ORDER

#13

GS-10F-0347P

Elijah Knight, PE

R R o m a n y k C o n s u lt in g \R

C C

A E

C

C o n s u lt in g \0

P ro je c ts

\V

IS

N

\L if e

S a fe ty \0

M o d e l\

A tl a n ta \B u ild in g s S u rv e y e d

\A T

-1

F o rt M c P h e rs o n

O P

C \A

T -1

F o rt

M c P h e rs o n O

P C

.r v t

/1

/2

:5

:2

A M

FIRE/SMOKE DOOR INSPECTION FLOOR PLAN -

LEVEL 02

E.K. HP

LS0402

VISN 7 ATLANTA

07/31/2018

VISN 7

ATLANTA

100% SUBMITTAL

Note Number Fire Door Note

1 VISIBLE SIGN OF DAMAGE

2 PARTS MISSING OR BROKEN

3 SURFACE HOLES IN DOOR OR FRAME

4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE

4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE

5 FAILED GLAZING AND FRAME INSPECTION

6 SELF-CLOSING DEVICE NOT OPERATIONAL

7 COORDINATOR NOT OPERATIONAL

8 LATCHING HARDWARE NOT OPERATIONAL

9 AUXILIARY HARDWARE INTERFERENCE

10 EDGE CLEARANCE NOT ACCEPTABLE

11 DOOR CLEARANCE NOT ACCEPTABLE

12 SIGNAGE DOES NOT MEET REQUIREMENTS

13 FIELD MODIFICATIONS VOID LABEL

Note Number Fire Smoke Door Note

1 VISIBLE SIGN OF DAMAGE

2 PARTS MISSING OR BROKEN

3 SURFACE HOLES IN DOOR OR FRAME

4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE

4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE

5 FAILED METAL DOOR FRAME INSPECTION

6 FAILDED GLAZING AND FRAME INSPECTION

7 SELF-CLOSING DEVICE NOT OPERATIONAL

8 COORDINATOR NOT OPERATIONAL

9 LATCHING HARDWARE NOT OPERATIONAL

10 AUXILIARY HARDWARE INTERFERENCE

11 EDGE CLEARANCE NOT ACCEPTABLE

12 DOOR CLEARANCE NOT ACCEPTABLE

NORTH ARROW

FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 02

3/32" = 1'-0"

Sheets
G-04 - COVER
G-04X1 - GENERAL SHEET
G-04X2 - GENERAL SHEET
LS040B - FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - BASEMENT
LS0401 - FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 01
LS0402 - FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 02

File details come from the government source that posted it. Updated .