04 Series DOORS - 100 AT-125 Fort McPherson OPC.pdf
PDF 1 MB Posted
- Attached to
- Fire Sprinkler Testing
- Solicitation number
- 36C24724Q0269
About this file
This document package includes drawings and specifications for a fire sprinkler testing project at a Department of Veterans Affairs medical center. The project involves inspecting and testing fire sprinkler systems throughout multiple buildings on the VA campus to ensure compliance with NFPA standards. Key requirements include testing sprinkler piping and components, fire pumps and related equipment. The scope also involves inspecting sprinkler heads and identifying any deficiencies. The drawings provide floor plans delineating the locations of sprinkler systems, standpipes and related infrastructure in various facility areas. Relevant details are noted such as sprinkler types, pipe sizes and equipment specifications. This project appears aimed at confirming the ongoing integrity and reliability of critical life safety systems at the VA medical center.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INDEX OF DRAWINGSVICINITY MAP PROJECT TEAMBUILDING SUMMARYANNOTATION DRAWING SYMBOLS
OWNER
Department of Veterans Affairs Tuscaloosa VA Medical Center 3701 Loop Road East Tuscaloosa AL 35404-5088
PROJECT MANAGER
Romanyk Consulting 3308 Preston Road, Suite 350-164 Plano, TX 75093
Sherri Mitchell, Contracting Officer Sherri.mitchell@va.gov
334-272-4670, ext 2238
Joshua Leow, COR Joshua.leow@va.gov
Elijah Knight, PE, MSEM elijah.knight@romanykconsulting.com
855-424-3838 ext.323 405-640-1586 cell
MECHANICAL ENGINEER
PROJECT ARCHITECT
John Slattery, RA john.slattery@romanykconsulting.com
855-424-3838 ext.336 918-430-6020 cell
Brad Cain, PE brad.cain@romanykconsulting.com
855-424-3838 ext.335 864-908-8304 cell
Romanyk Consulting 3308 Preston Road, Suite 350-164 Plano, TX 75093
Romanyk Consulting 3308 Preston Road, Suite 350-164 Plano, TX 75093
LIFE SAFETY ENGINEER
Frank Van Overmeiren fvanovermeiren@fpc-consultants.com
317-486-5188 ext.13
FP&C Consultants, Inc.
1520 Main Street Indianapolis, IN 46224
ROOM NAME
ROOM NAME / NUMBER
NORTH ARROW
NORTH ARROW WITH TRUE
NORTH INDICATION
Name Elevation
FLOOR LEVEL &
NAME
SHEET KEYNOTE1
XXX-XXXX-XX-XXXXX DOOR TAG
1 SHEET KEYNOTE
XXX-XXX-XX-XXXXX
WALL
PENETRATION TAG
XXX-XXX-XX-DPXXX DAMPER TAG
The A/E team, including architects, engineers, surveyors, and professional consultants shall survey and inspect the following VISN 7 VA Medical Center for Life safety deficiencies according to 2015 NFPA 101 Life Safety Code and Joint Commission Standard LS.01.01.01, EP 2 and provide comprehensive as-built Life Safety Plans (LSP)
SCOPE OF WORK SUMMARY:
• Tuskegee
• Montgomery
Team shall provide a list of discrepancies based off their findings and provide recommended methods for corrections. Team shall also update the facilities current life/fire safety plans to reflect existing as-built conditions based off the survey. Team shall also survey the facility to locate existing fire dampers and provide accurate as-built drawings.
A/E shall assume all areas of the campus are, and must remain fully operational, and that inspections may require coordination with the Owner for after-hours access, accompanied access and protected access (for medically sensitive areas, etc.), and shall include all such work as part of the A/E Scope of Work (SOW).
Life Safety inspection shall include the following. Inspecting all fire walls (including doors, door frames, and hardware) smoke walls, locations of all fire extinguishers, smoke detectors, smoke compartments, and exit signs.
A/E shall reference NFPA 101 and other NFPA applicable codes and provide the follow for each deliverable.
• Columbia
• Atlanta
• Augusta UD
• Augusta DD
• Dublin
• Charleston
LS0101A
LEVEL
DISCIPLINE
SECTION LETTER
WITHIN LEVEL
SERIES
01 SERIES = TJC DRAWINGS
02 SERIES = WALL PENETRATION DEFICIENCY DRAWINGS
03A SERIES = LIFE SAFETY DRAWINGS
03B SERIES = EXIT AND OCCUPANCY DRAWINGS
04 SERIES = FIRE/SMOKE DOOR DRAWINGS
05 SERIES = FIRE/SMOKE DAMPER DRAWINGS
FIRE/SMOKE DOORS - DRAWING LIST
' 6
G ra p h ic S ca le
/2
1'
-0
G ra p h ic S ca le
/3 2"
'-0
' G ra p h ic S ca le
/1 6"
'-0
' G ra p h ic
S ca le
/8
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
/8
1'
-0
' G ra p h ic
S ca le
/2
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
'-0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
VISN 7 LIFE SAFETY SURVEY AND
DRAWING UPDATE, TASK ORDER
#13
GS-10F-0347P
Elijah Knight, PE
VISN 7 LIFE SAFETY SURVEY AND DRAWING UPDATE
BPA ORDER NO. VA247-14-A-0028 - TASK ORDER #13
EE
ES
S
OF
M
R C
D
T
T T
II
N
U A
A A
V
RAP
M
N
T
T
OF
E E
D
R S
I
FA
A
N T
S R
F
AEE
2017 LIFE SAFETY DOCUMENTATION
FINAL
Contract: GS-10F-0347P Task Order: VA247-17-F-2259
R R o m a n y k C o n s u lt in g \R
C C
A E
C
C o n s u lt in g \0
P ro je c ts
\V
IS
N
\L if e
S a fe ty \0
M o d e l\
A tl a n ta \B u ild in g s S u rv e y e d
\A T
-1
F o rt M c P h e rs o n
O P
C \A
T -1
F o rt
M c P h e rs o n O
P C
.r v t
/1
/2
:5
:2
A M
COVER
E.K. HP
G-04
VISN 7 ATLANTA
07/31/2018
VISN 7
ATLANTA
Building 125 - FT McPHERSON OPC
100% SUBMITTAL
FIRE/SMOKE DOORS
04 - GENERAL
G-04 COVER
G-04X1 GENERAL SHEET
G-04X2 GENERAL SHEET
04 - FIRE/SMOKE DOOR
LS040B FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - BASEMENT
LS0401 FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 01
LS0402 FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 02
Grand total: 6
Prepared for:
100% Submission for
Fort McPherson VA Clinic Atlanta, GA
Revisions: Date:
l lllllll
OO OO O O ∅ ∅∅ ∅ ∅
' 6
G ra p h ic S ca le
/2
1'
-0
G ra p h ic S ca le
/3 2"
'-0
' G ra p h ic S ca le
/1 6"
'-0
' G ra p h ic
S ca le
/8
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
/8
1'
-0
' G ra p h ic
S ca le
/2
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
'-0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
VISN 7 LIFE SAFETY SURVEY AND
DRAWING UPDATE, TASK ORDER
#13
GS-10F-0347P
Elijah Knight, PE
R R o m a n y k C o n s u lt in g \R
C C
A E
C
C o n s u lt in g \0
P ro je c ts
\V
IS
N
\L if e
S a fe ty \0
M o d e l\
A tl a n ta \B u ild in g s S u rv e y e d
\A T
-1
F o rt M c P h e rs o n
O P
C \A
T -1
F o rt
M c P h e rs o n O
P C
.r v t
/1
/2
:5
:2
A M
GENERAL SHEET
E.K. HP
G-04X1
VISN 7 ATLANTA
07/31/2018
VISN 7
ATLANTA
100% SUBMITTAL
Revisions: Date:
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND
STAIRWELLS OF 4 OR MORE STORIES.
WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.
DUCTS: ALL DUCT PENETRATIONS ARE PROTECTED BY FIRE DAMPERS.
PENETRATIONS: ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP
MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL
PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE
WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON
THE TOP OF THE FLOOR.
DOORS: ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).
11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT AT
LEAST ANNUALLY (NFPA 80 5.2.4.1)
2-HOUR FIRE BARRIER
THIS APPLIES TO 1-HOUR FIRE RATED OCCUPANCY SEPERATIONS, HAZARDOUS ROOM
ENCLOSURES AND STAIRWELLS 3 STORIES OR LESS.
WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.
DUCTS: STEEL DUCT PENETRATIONS NOT REQUIRED TO BE PROTECTED BY
FIRE DAMPERS.
PENETRATIONS: ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP
MATERIALS FOR PROTECTING 1-HOUR WALL ASSEMBLIES. WALL
PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE
WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON
THE TOP OF THE FLOOR.
DOORS*: ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 3/4 OR 1-HOUR DOOR (NFPA 80 4.3.1)*
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).
11.PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT
AT LEAST ANNUALLY (NFPA 80 5.2.4.1)
* 1-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 3
STORIES OR LESS.
1-HOUR FIRE BARRIER
WALL: IF THE HAZARDOUS ROOM HAS A SUSPENDED CEILING CONSTRUCTED
TO LIMIT TRANSFER OF SMOKE, THE WALL HAS NO FIRE RESISTANCE
RATING AND MAY TERMINATE AT THE CEILING. IF THE ROOM DOES NOT
HAVE A SUSPENDED CEILING, THE WALL HAS NO FIRE RESISTANCE
RATING AND SHALL EXTEND TO THE DECK ABOVE.
DUCTS: STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED
BY FIRE DAMPERS OR SMOKE DAMPERS.
PENETRATIONS: SEALED WITH NON-FIRE-RATED MATERIALS TO BE RESISTIVE. USE OF
LISTED FIRESTOP MATERIALS IS NOT REQUIRED.
DOORS: EXISTING HAZARDOUS ROOMS:
1. NON-LABELED FRAME (NFPA 101 19.3.7.9)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 19.3.7.6)
3. MAXIMUM 1296 SQ. IN. WINDOW (NFPA 101 19.3.6.3.17)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 19.3.6.3.5)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 19.3.2.1.3)
6. MAXIMUM 1/8" GAP (NFPA 101 19.3.6.3.1)
7. MAXIMUM 1" UNDERCUT (NFPA 101 19.3.6.3.4)
8. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 19.3.2.1.2)
9. SWING IN ANY DIRECTION
10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST
ANNUALLY (NFPA 105 5.2.1.1)
SMOKE RESISTIVE HAZARDOUS ROOMS
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS
OF 4 OR MORE STORIES. THIS COMBINATION WALL IS WHERE A PORTION OF THE 2-HOUR
RATED WALL IS ALSO PART OF THE SMOKE WALL.
WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.
DUCTS: ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE
AND SMOKE DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED
WHERE ADJACENT SMOKE COMPARTMENTS ARE PROTECTED BY
QUICK RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.
PENETRATIONS: ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP
MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL
PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE
WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON
THE TOP OF THE FLOOR.
DOORS: ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)
10.SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).
11.PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT
AT LEAST ANNUALLY (NFPA 80 5.2.4.1)
2-HOUR FIRE AND SMOKE BARRIER
SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR
DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS OF
MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND THE
BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE
REQUIRED TO BE OF 1 HOUR FIRE RESISTANCE RATING. (NFPA 101, 18.3.2.7.5) SMOKE ZONE
BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED TO BE OF
A 1/2 HOUR FIRE RESISTANCE RATING (NFPA 101, 19.3.7.3)
WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.
DUCTS: ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE DAMPERS.
SMOKE DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE
COMPARTMENTS ARE PROTECTED BY QUICK RESPONSE SPRINKLERS
THROUGHOUT EACH COMPARTMENT.
PENETRATIONS: ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS
FOR PROTECTING 1-HOUR FIRE AND SMOKE WALL ASSEMBLIES.
PENETRATIONS ARE TO BE FILLED ON BOTH SIDES OF THE WALL.
DOORS: ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:
1. NON-LABELED FRAME (NFPA 101 18.3.7.6)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 18.3.7.6)
3. MAXIMUM 1296 SQ. IN. WINDOW (NFPA 80 4.4.4)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18.3.7.8)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18.3.7.8)
6. MAXIMUM 1/8" GAP (NFPA 101 18.3.7.6.)
7. MAXIMUM 1" UNDERCUT (NFPA 101 19.3.6.3.4)
8. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 18.3.7.6)
9. SWING IN DIRECTION OPPOSITE OF EACH OTHER (NFPA 101 18.3.7.6)
10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY
(NFPA 105 5.2.1.1)
SMOKE ZONE BARRIERS
IF THE SMOKE COMPARTMENT IS SPRINKLERED, THE WALL SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE. THE WALL HAS NO REQUIRED FIRE RESISTANCE RATING AND MAY TERMINATE AT A CEILING CONSTRUCTED TO LIMIT TRANSFER OF SMOKE. DOORS ARE MANUALLY CLOSED IN AN EMERGENCY NFPA 101, 18.3.6.2 & 19.3.6.2
IF THE SMOKE COMPARTMENT IS NOT SPRINKLERED, THE WALL SHALL BE CONTINUOUS FROM THE FLOOR TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK ABOVE. CORRIDOR WALL SHALL HAVE A MINIMUM 1/2 HOUR FIRE RESISTANCE RATING. DOORS ARE MANUALLY CLOSED IN AN EMERGENCY NFPA 101 19.3.6.2
DOORS: DOORS THAT ARE NOT PART OF A RATED WALL:
1. NON-LABELED FRAME (NFPA 101 18.3.6.3.1, 19.3.6.3 & 19.3.6.3.3)
2. NON-RATED DOORS PERMITTED IF SPRINKLERED (NFPA 101 18.3.6.3.1, 19.3.6.3.2(2))
3. 20-MINUTE OR SOLID WOOD CORE DOOR IF NOT SPRINKLERED (NFPA 101 19.3.6.3.1)
4. POSITIVE LATCHING EXCEPT TOILETS, SHOWER AND SINK
CLOSETS (NFPA 101 18.3.6.3.6 & 19.3.6.3.6)
5. SELF-CLOSING NOT REQUIRED (NFPA 101 19.3.6.3.11)
6. NO MAXIMUM GAP (NFPA 101 18.3.6.3.1 & 19.3.6.3.3)
7. MAXIMUM 1" UNDERCUT (NFPA 101 18.3.6.3.1 & 19.3.6.3.4)
8. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 18/19.3.6.3.12)
9. TRANSFER GRILLS NOT PERMITTED EXCEPT TOILETS, SHOWER AND SINK CLOSETS
(NFPA 101 18/19.3.6.4)
10. SWING IN ANY DIRECTION
11. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.1.1)
HEALTH CARE OCCUPANCY CORRIDORS
NOTE: ALL CODE REFERENCES ARE PER THE 2015 EDITION OF NFPA 101 LIFE SAFETY CODE AND THE OTHER APPLICABLE CODES. FEDERAL FACILITIES FOLLOW 2015 LIFE SAFETY CODE.
FORMER DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER ZONE.
BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY THE FIRE
DEPARTMENT PER SECTION 15.7.4.3 OF NFPA 99-2015 EDITION AND PRIVATE MODE AUDIBLE
REQUIREMENTS OF SECTION 18.4:4 OF NFPA 72-2016 EDITION.
WALL: WALL EXTENDS FROM FLOOR TO SUSPENDED CEILING OR DECK ABOVE.
DUCTS: NO MINIMUM REQUIREMENTS.
PENETRATIONS: NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A
SUSPENDED CEILING. PENETRATIONS BELOW A SUSPENDED CEILING
OR DECK SEALED WITH NON-FIRE-RATED MATERIALS TO BE SMOKE
RESISTIVE.
DOORS: NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC
CLOSING IN AN EMERGENCY.
NON-RATED SMOKE PARTITION
SUITES
HEALTHCARE AREA OPEN TO CORRIDOR WITH 24/7 SUPERVISION - NO SMOKE DETECTION REQUIRED.
HEALTHCARE AREA OPEN TO CORRIDOR - SMOKE DETECTION PROVIDED.
(COLOR #3) (COLOR #4) (COLOR #230)
(COLOR #1) (COLOR #6) (COLOR #30)
(COLOR #2)
(COLOR #2)
(COLOR #3)
' 6
G ra p h ic S ca le
/2
1'
-0
G ra p h ic S ca le
/3 2"
'-0
' G ra p h ic S ca le
/1 6"
'-0
' G ra p h ic
S ca le
/8
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
/8
1'
-0
' G ra p h ic
S ca le
/2
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
'-0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
VISN 7 LIFE SAFETY SURVEY AND
DRAWING UPDATE, TASK ORDER
#13
GS-10F-0347P
Elijah Knight, PE
R R o m a n y k C o n s u lt in g \R
C C
A E
C
C o n s u lt in g \0
P ro je c ts
\V
IS
N
\L if e
S a fe ty \0
M o d e l\
A tl a n ta \B u ild in g s S u rv e y e d
\A T
-1
F o rt M c P h e rs o n
O P
C \A
T -1
F o rt
M c P h e rs o n O
P C
.r v t
/1
/2
:5
:2
A M
GENERAL SHEET
E.K. HP
G-04X2
VISN 7 ATLANTA
07/31/2018
VISN 7
ATLANTA
100% SUBMITTAL
Revisions: Date:
APPLICABLE CODES AND STANDARDS:
1. THE BUILDING WAS DESIGNED TO THE 1960 EDITION OF NFPA 101, LIFE SAFETY CODE.
2. THE 1960 PUBLIC BUILDING AMENDMENT ACT (PL100-678) REQUIRES ALL FEDERAL AGENCIES TO FOLLOW
THE LATEST EDITIONS OF NATIONALLY RECOGNIZED FIRE AND LIFE SAFETY CODES. THE VA HAS ADOPTED THE NATIONAL FIRE CODES PUBLISHED BY THE NATIONAL FIRE PROTECTION ASSOCIATION. LIFE SAFETY REQUIREMENTS ARE SPECIFICALLY ADDRESSED IN THE 2018 EDITION OF NFPA 101, LIFE SAFETY CODE.
3. ALL NEW CONSTRUCTION OR BUILDING RENOVATIONS ARE REQUIRED TO COMPLY WITH THE LATEST EDITION OF NFPA 101 OR IT'S REFERENCED STANDARDS. EXISTING BUILDING CONDITIONS ARE REQUIRED TO COMPLY WITH THE APPLICABLE CODES OR STANDARDS AT THE TIME OF BUILDING DESIGN AND THE APPLICABLE PROVISIONS FOR EXISTING BUILDINGS IN CURRENT EDITIONS OF APPLICABLE
CODES AND STANDARDS.
4. OTHER NFPA CODES AND STANDARDS:
A. NFPA 10 - PORTABLE FIRE EXTINGUISHERS, 2018 EDITION.
B. NFPA 13 - SPRINKLER SYSTEMS, 2016 EDITION.
C. NFPA 14 - STANDPIPE SYSTEMS, 2016 EDITION.
D. NFPA 20 - FIRE PUMPS, 2016 EDITION
E. NFPA 70 - NATIONAL ELECTRIC CODE, 2017 EDITION.
F. NFPA 72 - NATIONAL FIRE ALARM CODE, 2016 EDITION.
G. NFPA 75 - ELECTRONIC COMPUTER EQUIPMENT, 2017 EDITION.
H. NFPA 80 - FIRE DOORS, 2016 EDITION.
I. NFPA 90A&B - HEATING AND AIR CONDITIONING SYSTEMS, 2018 EDITION.
J. NFPA 96 - COMMERCIAL COOKING EQUIPMENT, 2017 EDITION.
K. NFPA 99 - HEALTH CARE FACILITIES CODE, 2018 EDITION.
L. NFPA 105 - SMOKE DOORS, 2016 EDITION.
M. NFPA 110 - EMERGENCY POWER SYSTEMS, 2016 EDITION.
N. NFPA 241 - CONSTITUTION AND DEMOLITION, 2013 EDITION.
PENETRATIONS:
1. PRIOR TO THE EARLY 1990'S, THE STANDARD INDUSTRY PRACTICE FOR THE SEALING OF PENETRATIONS WAS TO
USE THE SAME CONSTRUCTION MATERIALS AS HOW THE WALL/FLOOR WAS CONSTRUCTED. CONCRETE PATCH WAS USED FOR CONCRETE FLOORS. MORTAR JOINT COMPOUND WAS USED FOR MASONRY WALLS. GYPSUM
PATCH COMPOUND WAS USED USED FOR GYPSUM WALLS.
2. PRIOR TO THE EARLY 1990'S, THE MANUFACTURES PUBLISHED INSTRUCTIONS FOR FIRE RESISTIVE WALL AND FLOOD CONSTRUCTION REQUIRED THE USE OF THE SAME CONSTRUCTION MATERIALS AS HOW THE WALL/FLOOR
WAS CONSTRUCTED TO SEAL PENETRATIONS.
3. THE FIRST LISTINGS OF FIRESTOP MATERIALS WAS IN 1991. THE FIRST CODE REQUIREMENTS TO UTILIZE LISTED
FIRESTOP MATERIALS OCCURRED IN 1992 EDITIONS OF CODES AND STANDARDS.
4. ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR PROTECTING THE REQUIRED RATING
OF THE WALL ASSEMBLY.
5. EXISTING PENETRATIONS SEALED WITH THE SAME CONSTRUCTION MATERIAL AS THE WALL/FLOOR, MAY REMAIN
AS AN EXISTING PREVIOUSLY APPROVED CONSTRUCTION METHOD.
6. EXISTING PENETRATIONS THAT REQUIRE REPAIR OR REPLACEMENT REQUIRE THE USE OF LISTED FIRESTOP
MATERIALS.
FIRE SPRINKLER SYSTEM:
1. THE COMBINATION STANDPIPE AND FIRE SPRINKLER SYSTEM WAS DESIGNED TO THE 2016 EDITION OF NFPA 13.
2. QUICK RESPONSE TYPE SPRINKLERS ARE INSTALLED THROUGHOUT MOST OF THE BUILDING. STANDARD
RESPONSE TYPE SPRINKLERS ARE INSTALLED IN THE ELEVATOR MACHINE ROOMS.
3. SPRINKLERS WERE INSTALLED IN LIGHT HAZARD AREAS INCLUDING; CORRIDORS, OFFICES, PATIENT CARE AND
PATIENT SLEEPING ROOMS AT LIGHT HAZARD 0.10 GPM/1500 SQ. FT. DENSITY.
4. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP I AREAS INCLUDING; LABORATORIES (WITHOUT
FLAMMABLE LIQUIDS), MECHANICAL EQUIPMENT ROOMS, ELECTRICAL SWITCH GEAR ROOMS, REPAIR SHOPS AND
STORAGE ROOMS UNDER 250 SQ. FT. AT A 0.15 GPM/1500 SQ. FT. DENSITY.
5. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP II AREAS INCLUDING GENERAL STORAGE ROOMS OVER 250 SQ. FT. AND LABORATORIES (WITH THE USE OF FLAMMABLE LIQUIDS) AT A 0.20 GPM/1500 SQ. FT.
DENSITY.
FIRE ALARM SYSTEM:
1. THE FIRE ALARM SYSTEM WAS DESIGNED TO THE 2013 EDITION OF NFPA 72, NATIONAL FIRE ALARM CODE.
2. PRIVATE MODE BUILDING OCCUPANT NOTIFICATION IS INSTALLED PER SECTIONS 19.3.4.3.1 AND 9.6.3.6.3 OF NFPA
101-2015 EDITION.
3. PRIVATE MODE AUDIBLE DEVICES (SPEAKERS) ARE INSTALLED IN CORRIDORS AND LARGER ROOMS OR SUITES
PER SECTION 18.4.4.1 OF NFPA 72-2016 EDITION.
4. PRIVATE MODE VISIBLE DEVICES (STROBES) ARE INSTALLED AT REDUCED QUANTITY AND SPACING PER SECTION
18.6 OF THE NFPA 72-2016 EDITION.
5. STROBE CIRCUITS ARE REQUIRED TO BE SYNCHRONIZED IN ACCORDANCE WITH SECTION 18.5.5.4.2 OF NFPA
72-2016 EDITION.
SUITES:
1. SUITES ARE UTILIZED TO ILLUSTRATE AREAS WITH THE SAME FUNCTION, USE OF HALLWAYS OR AISLES AND THE
END OF PUBLIC EXIT CORRIDORS. NO EXIT SIGNS OUTSIDE OF THE SUITE DIRECT OCCUPANTS INTO A SUITE TO
REACH AN EXIT.
2. HEALTH CARE OCCUPANCY SUITES ARE REGULATED BY FUNCTION AND SIZE.
3. HEALTH CARE OCCUPANCY PATIENT SLEEPING SUITES:
A. SINGLE EXIT SUITE - 1,000 SQ. FT. (NFPA 101 -19.2.5.7.2.2)
B. MULTI EXIT SUITE - 5,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.A)
C. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS OR COMPLETE SMOKE DETECTION - 7,500 SQ.
FT. (NFPA 101 - 19.2.5.7.2.3.B)
D. MULTI EXIT SUITE WITH DIRECT VISUAL SUPERVISION, QUICK RESPONSE SPRINKLERS AND COMPLETE
SMOKE DETECTION - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.C)
4. PATIENT CARE NON - SLEEPING SUITES:
A. SINGLE EXIT SUITE - 2,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.1.B)
B. MULTI EXIT SUITE - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.3.2)
C. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS AND COMPLETE SMOKE DETECTION OR QUICK
RESPONSE SPRINKLERS - 12,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.2.A)
D. MULTI EXIT SUITE WITH QUICK RESPONSE SPRINKLERS AND COMPLETE SMOKE DETECTION (NFPA 101 -
19.2.5.7.3.2.B)
5. HEALTH CARE OCCUPANCY NON - PATIENT - CARE SUITES FOLLOW THE TRAVEL DISTANCE REQUIREMENTS
AS LISTED IN TABLE A.7.6 OF NFPA 101.
6. SUITES IN OTHER OCCUPANCIES ARE NOT REGULATED IN SIZE BUT STILL FOLLOW THE TRAVEL DISTANCE
REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.
BUILDING # FLOOR
HEALTH CARE
OCCUPANCY
TOTAL
508C 1 49,031 0 22,513 0 71,544
AMBULATORY HEALTH
CARE OCCUPANCY
BUSINESS
OCCUPANCY
INDUSTRIAL
OCCUPANCY
508ASCA 2 0 0 56,228 0 56,228
508ASCA 1 0 0 56,573 0 56,573
125 2 0 0 22,258 0 22,258
125 1 0 0 41,126 0 41,126
128 2 0 0 8,723 0 8,723
128 1 0 0 8,723 0 8,723
SUB TOTAL 0 0 17,446 0 17,446
129 2 0 0 8,696 0 8,696
129 1 0 0 8,692 0 8,692
SUB TOTAL 0 0 17,388 0 17,388
130 1 0 0 8,721 0 8,721
131 2 0 0 0 0 9,517
SUB TOTAL 0 0 8,721 0 17,442
131 GROUND 0 0 9,516 0 9,516
SUB TOTAL 0 0 9,516 0 28,551
GRAND TOTAL 49,031 0 263,657 0 340,444
OCCUPANCY TABLE
DORMITORY
OCCUPANCY
9,517
8,721
19,035
27,756
SUB TOTAL
SUB TOTAL 0 0 112,801 0 112,8010
125 BASEMENT 0 0 11,888 0 11,8880
SUB TOTAL 0 0 75,272 0 75,2720
130 2 0 0 0 0 8,7218,721
131 1 0 0 0 0 9,5189,518
49,031 0 22,513 0 71,5440
LEGEND
l lllllll
O OO
OO OO
KEY NOTES
KEY NOTES
l llll l l l l l l l l ll llll l l l l l l l l l l l l l lllllllllllllll l l l l l l l l l l l l l l l l l l ll l l l l l l l ll llll l l l l l l l l l l llll l l l l l ll lll
DOOR FAILS INSPECTION TEST
DOOR PASSES INSPECTION TEST
FB1 = FIRE BARRIER 1HR
FB2 = FIRE BARRIER 2HR
FB1/2 = FIRE BARRIER 30 MIN
FSB1 = FIRE / SMOKE BARRIER 1HR
FSB2 = FIRE / SMOKE BARRIER 2HR
SP0 = SMOKE PARTITION NON-RATED
SB0 = SMOKE BARRIER NON-RATED
EHR = EXISTING HAZARDOUS ROOMS
HCO = HEALTH CARE OCCUPANCY
NON-RATED
NON-RATED INTERIOR PARTITION WALL
XXX-XXXX-XX-XXXXX DOOR TAG
105 SF
STOR
BA002
101 SF
OFFICE
BA003
856 SF
MECH RM.
BA004
106 SF
SUPER. OFF
BA005
111 SF
COMM.
BA006
195 SF
ELEC RM.
BA007
150 SF
BREAK RM
BA008
688 SF
COMMON SHOP
BA009
103 SF
UPS
BA010
97 SF
PARTS
BA011
202 SF
OFFICE
BA012
97 SF
FORMS & FILES
BA014
102 SF
STORAGE
BA015
101 SF
CHIEF LOGISTICS
BA016
100 SF
UNISEX TLT
BA01799 SF
MTF FORM STOR
BA018
50 SF
FEMALE TLT
BA019
99 SF
BA020
50 SF
MALE TLT
BA021
255 SF
NOT KNOWN
BA023
278 SF
LOADING DOCK
/ RECEIVING /
PROCESSING
BA024
58 SF
HOLDING
WASTE
BA025
238 SF
EMS STORAGE
BA026
236 SF
OIT STORAGE
BA027
111 SF
OFFICE
BA028
107 SF
OFFICE
BA029
149 SF
NOT KNOWN
BA030
472 SF
ENGINEERING
BA031
791 SF
CALL CENTER -
OFF SPACE
BA032
97 SF
NOT KNOWN
BA034
475 SF
COMPUTER RM
BA036
73 SF
ELEV. MACH.
RM.
BA001
106 SF
NOT KNOWN
BA03
173 SF
SOILED LINEN
BA022
73 SF
CYLINDER
HOLDING
BA037
495 SF
MEDICAL GAS EQUIP
BA038
707 SF
CORR
BA041
222 SF
CORR
BA040 61 SF
ELEV.
EB-NO. 3
138 SF
STAIR
SB-NO. 4
235 SF
CORR
BA042
390 SF
CORR
BA043
235 SF
CORR
RCCB01R
537 SF
CALL CENTER
RCCB02R
135 SF
STAIR
SB-NO. 2
FLAMMABLE
HAZARDOUS
STG.
AREAWAY
508-125-0B-DRF001
508-125-0B-DRF002
508-125-0B-DRF003
508-125-0B-DRF004
508-125-0B-DRS001
508-125-0B-DRS002
508-125-0B-DRS004
508-125-0B-DRS003
508-125-0B-DRS005
' 6
G ra p h ic S ca le
/2
1'
-0
G ra p h ic S ca le
/3 2"
'-0
' G ra p h ic S ca le
/1 6"
'-0
' G ra p h ic
S ca le
/8
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
/8
1'
-0
' G ra p h ic
S ca le
/2
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
'-0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
VISN 7 LIFE SAFETY SURVEY AND
DRAWING UPDATE, TASK ORDER
#13
GS-10F-0347P
Elijah Knight, PE
R R o m a n y k C o n s u lt in g \R
C C
A E
C
C o n s u lt in g \0
P ro je c ts
\V
IS
N
\L if e
S a fe ty \0
M o d e l\
A tl a n ta \B u ild in g s S u rv e y e d
\A T
-1
F o rt M c P h e rs o n
O P
C \A
T -1
F o rt
M c P h e rs o n O
P C
.r v t
/1
/2
:5
:2
A M
FIRE/SMOKE DOOR INSPECTION FLOOR PLAN -
BASEMENT
E.K. HP
LS040B
VISN 7 ATLANTA
07/31/2018
VISN 7
ATLANTA
100% SUBMITTAL
Note Number Fire Door Note
1 VISIBLE SIGN OF DAMAGE
2 PARTS MISSING OR BROKEN
3 SURFACE HOLES IN DOOR OR FRAME
4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE
4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE
5 FAILED GLAZING AND FRAME INSPECTION
6 SELF-CLOSING DEVICE NOT OPERATIONAL
7 COORDINATOR NOT OPERATIONAL
8 LATCHING HARDWARE NOT OPERATIONAL
9 AUXILIARY HARDWARE INTERFERENCE
10 EDGE CLEARANCE NOT ACCEPTABLE
11 DOOR CLEARANCE NOT ACCEPTABLE
12 SIGNAGE DOES NOT MEET REQUIREMENTS
13 FIELD MODIFICATIONS VOID LABEL
Note Number Fire Smoke Door Note
1 VISIBLE SIGN OF DAMAGE
2 PARTS MISSING OR BROKEN
3 SURFACE HOLES IN DOOR OR FRAME
4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE
4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE
5 FAILED METAL DOOR FRAME INSPECTION
6 FAILDED GLAZING AND FRAME INSPECTION
7 SELF-CLOSING DEVICE NOT OPERATIONAL
8 COORDINATOR NOT OPERATIONAL
9 LATCHING HARDWARE NOT OPERATIONAL
10 AUXILIARY HARDWARE INTERFERENCE
11 EDGE CLEARANCE NOT ACCEPTABLE
12 DOOR CLEARANCE NOT ACCEPTABLE
NORTH ARROW
FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - BASEMENT
3/32" = 1'-0" l lllllll
O OO
OO OO
KEY NOTES
KEY NOTES
l llll l l l l l ll lll l l l l l l l l l ll l l l l l l l l l l ll lll l ll l l l l l l l l l llll l lllll l l l l l ll lllll l l l l
DOOR FAILS INSPECTION TEST
DOOR PASSES INSPECTION TEST
FB1 = FIRE BARRIER 1HR
FB2 = FIRE BARRIER 2HR
FB1/2 = FIRE BARRIER 30 MIN
FSB1 = FIRE / SMOKE BARRIER 1HR
FSB2 = FIRE / SMOKE BARRIER 2HR
SP0 = SMOKE PARTITION NON-RATED
SB0 = SMOKE BARRIER NON-RATED
EHR = EXISTING HAZARDOUS ROOMS
HCO = HEALTH CARE OCCUPANCY
NON-RATED
NON-RATED INTERIOR PARTITION WALL
XXX-XXXX-XX-XXXXX DOOR TAG
480 SF
WAIT
1A400
193 SF
RECEPTION
1A401
99 SF
PUB MALE TLT
1A402
101 SF
PULIC FEMALE
TLT
1A403
69 SF
J.C.
1A404
100 SF
EXAM RM 1
1A405
100 SF
EXAM RM 3
1A406
101 SF
PHYS. OFF. 1
1A407
101 SF
PHYS. OFF. 2
1A408
100 SF
EXAM RM 2
1A409
100 SF
EXAM RM 4
1A410
157 SF
TREAT. RM.
1A411
86 SF
SOILED UTIL
1A412
99 SF
NRS OFF
1A413
100 SF
EXAM RM 5
1A414
100 SF
EXAM RM 7
1A415
101 SF
PHYS. OFF. 3
1A416
99 SF
PHYS. OFF. 4
1A417
100 SF
EXAM RM 6
1A418
99 SF
EXAM RM 8
1A419
208 SF
WAIT (SPECIALTY CLINIC)
1A420
147 SF
STAIR
S1-NO. 1
79 SF
SCRN. RM. 4
1A421
79 SF
SCRN. RM. 3
1A422
80 SF
SCRN. RM. 2
1A423
77 SF
SCRN. RM. 1
1A424
229 SF
OFFICE
1A425
100 SF
EXAM RM 12
1A426
47 SF
ISO. TLT
1A427
100 SF
EXAM RM 10
1A428
100 SF
CHIEF OFF
1A429
100 SF
DR. OFF 5
1A430
100 SF
EXAM RM 11
1A431
100 SF
EXAM RM 9
1A432
100 SF
EXAM RM 6
1A433
99 SF
DR. OFF 3
1A434
95 SF
EXAM RM 5
1A435
100 SF
EXAM RM 8
1A436
100 SF
EXAM RM 4
1A437
100 SF
DR. OFF 4
1A438
101 SF
DR. OFF 2
1A439
100 SF
EXAM RM 7
1A440
100 SF
EXAM RM 3
1A441
101 SF
NRS OFF 2
1A442 74 SF
SOILED UTIL
1A443
100 SF
EXAM RM 2
1A444
149 SF
OMNI CELL
1A445
101 SF
SPINAL
1A446
102 SF
SPINAL
1A447
100 SF
EXAM RM 1
1A448
134 SF
BREAK RM
1A449
311 SF
GROUP
1A450
AREAWAY
126 SF
STAFF MALE
TLT/LKR
1A451
127 SF
STAFF FEMALE
TLT/LKR
1A452
60 SF
COMM.
1A453
73 SF
ELEC.
1A454
109 SF
LOUNGE
1A455
91 SF
NCOIC
1A456
167 SF
SECTY./CLER. OFF
1A457
2,275 SF
CORR
RCC101R
261 SF
CORR
RCC102R
89 SF
WAIT
1A100
155 SF
ADMIN. OFF
1A101
182 SF
RECEPTION
1A103
44 SF
SPEC. TLT.
1A104
110 SF
AUDIO RM.
1A105
90 SF
VISION HGT. &
WGT.
1A106
109 SF
NRS OFF 3
1A107
116 SF
NCOIC
1A108
106 SF
OFFICE
1A109
288 SF
CONFERENCE
1A110
460 SF
NOT KNOWN
1A111
92 SF
IMMUN. RM.
1A112
96 SF
IMMUN. HOLD
1A113
99 SF
NRS OFF 2
1A114
84 SF
SCRN. RM. 3
1A115
100 SF
EXAM RM 9
1A116 118 SF
EXAM RM 11
1A117
101 SF
CHIEF OFF
1A118 66 SF
EXAM
1A119
101 SF
EXAM RM 10
1A120
100 SF
EXAM RM 12
1A121
80 SF
SCRN. RM. 2
1A122
83 SF
SCRN. RM. 1
1A123
85 SF
SUB-WAIT
1A124
100 SF
EXAM RM 5
1A125
100 SF
EXAM RM 7
1A126
101 SF
DR. OFF 3
1A127
99 SF
DR. OFF 4
1A128
100 SF
EXAM RM 6
1A129
97 SF
EXAM RM 8
1A130
83 SF
NOT KNOWN
1A131
120 SF
NRS OFF 1
1A132
101 SF
EXAM RM 1
1A133
100 SF
EXAM RM 3
1A134
101 SF
DR. OFF 1
1A135 101 SF
DR. OFF 2
1A136
101 SF
EXAM RM 2
1A137
100 SF
EXAM RM 4
1A138
91 SF
STAFF FEMALE
LKR
1A139
91 SF
STAFF FEMALE
TLT
1A140
100 SF
STAFF MALE TLT
1A141
118 SF
LOUNGE
1A142
86 SF
EXAM
1A143 173 SF
OFFICE
1A144
54 SF
STAFF
1A145
73 SF
OMNI CELL
1A146
420 SF
GROUP RM
1A147
103 SF
CRASH CART
1A148
66 SF
EXAM
1A149
67 SF
TLT
1A150
86 SF
PUB FEMALE
TLT
1A151
86 SF
PUB MALE
TOILET
1A152
70 SF
ELEC.
1A153
68 SF
COMM.
1A154
50 SF
J.C.
1A155
1,376 SF
CORR
RCC103R
523 SF
CORR
RCC104R
135 SF
STAIR
S1-NO. 2
67 SF
ELEV. MACH.
RM.
1A201
259 SF
NOT KNOWN
1A202
214 SF
COFFEE SHOP
1A203
789 SF
NOT KNOWN
1A204
103 SF
NOT KNOWN
1A205
103 SF
FEMALE TLT
1A206
186 SF
NOT KNOWN
1A207
121 SF
CHAMPUS
1A208
121 SF
PAT. ADVOC.
1A209
438 SF
WAIT
1A210
42 SF
NOT KNOWN
1A211
477 SF
WAITING
1A212
86 SF
TRASH
1A213
68 SF
SOILED UTILITY
1A214
53 SF
STAFF TLT
1A215
91 SF
OFFICE
1A216
94 SF
EXAM
1A217
102 SF
OFFICE
1A218
110 SF
EXAM
1A219
108 SF
OFFICE
1A220
85 SF
OFFICE
1A221
89 SF
OFFICE
1A222
95 SF
EXAM
1A223
96 SF
EXAM
1A224
111 SF
EXAM
1A225
112 SF
NOT KNOWN
1A226
323 SF
RECEPTION
1A227
331 SF
CLASS RM
1A228
200 SF
WAIT
1A229
326 SF
RADIOGRAPH / FLURO
1A230
110 SF
STAIR
S1-NO. 4
57 SF
ELEV.
E1-NO. 3
919 SF
CORR
RCC105R
49 SF
PUB TLT
1A235
260 SF
MAMMO. RM.
1A236
297 SF
RADIOGRAPH
1A237
40 SF
SPINAL
1A238
38 SF
SPINAL
1A239
12 SF
LINEN
1A240
23 SF
J.C.
1A241
90 SF
LOCK.
1A242
80 SF
TLT
1A243
95 SF
OFFICE
1A244
87 SF
STOR
1A245
120 SF
OFFICE
1A246
128 SF
OFFICE
1A247
99 SF
OFFICE
1A248
429 SF
CONFERENCE
RCC106R
106 SF
RECEPTION
RCC107R
52 SF
PAT TLT
RCC108R
575 SF
CORR
RCC109R
210 SF
CORR
RCC110R
40 SF
DRESS. 4
RCC111R
39 SF
DRESS. 3
RCC112R
48 SF
WAIT
RCC113R
776 SF
MFG/PRE PACK / DISPENSING /
BULK STOR.
1A300
193 SF
NOT KNOWN
1A301
43 SF
POISON
1A302
41 SF
NOT KNOWN
1A303
76 SF
DISPATCH
1A304
83 SF
CNTR. DRUG
1A305
100 SF
LOCK.
1A306
52 SF
NOT KNOWN
1A307
45 SF
NOT KNOWN
1A308
101 SF
CHIEF
1A309
45 SF
J.C.
1A310
151 SF
OFFICE
1A311
100 SF
THERAPIST
1A313
100 SF
EXAM
1A315
142 SF
OFFICE
1A317
67 SF
MALE TLT /
SHWR
1A320
19 SF
LINEN
1A319
67 SF
FEMALE
TLT/SHWR
1A318
98 SF
NOT KNOWN
1A323
105 SF
NOT KNOWN
1A324
79 SF
OFFICE
1A325
60 SF
J.C.
1A326
119 SF
WRK. STA.
1A327
625 SF
MECH RM.
1A329
283 SF
CORR
RCC114R
51 SF
ELEC.
RCC115R
766 SF
CORR
RCC116R
138 SF
CORR
RCC117R
58 SF
ELEV.
(PASSENGER)
E1-NO. 1
58 SF
ELEV.
(PASSENGER)
(ADD. NO. 4)
E1-NO. 2
72 SF
STAIR
S1-NO. 3
27 SF
VENDING AREA
RCC118R
493 SF
MAIN LOBBY
1A200
918 SF
CORR
RCC119R
27 SF
TEL. AREA
RCC120R
1,158 SF
CORR
RCC121R
144 SF
VEST
RCC122R
462 SF
CORR
RCC123R
468 SF
CORR
RCC124R199 SF
CORR
RCC125R
77 SF
1A321
80 SF
1A314
89 SF
1A322
82 SF
1A316
26 SF
3A117
508-125-01-DRF001
508-125-01-DRF002
508-125-01-DRF003
508-125-01-DRS001
508-125-01-DRS002
508-125-01-DRS003
508-125-01-DRS004
508-125-01-DRS005
' 6
G ra p h ic S ca le
/2
1'
-0
G ra p h ic S ca le
/3 2"
'-0
' G ra p h ic S ca le
/1 6"
'-0
' G ra p h ic
S ca le
/8
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
/8
1'
-0
' G ra p h ic
S ca le
/2
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
'-0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
VISN 7 LIFE SAFETY SURVEY AND
DRAWING UPDATE, TASK ORDER
#13
GS-10F-0347P
Elijah Knight, PE
R R o m a n y k C o n s u lt in g \R
C C
A E
C
C o n s u lt in g \0
P ro je c ts
\V
IS
N
\L if e
S a fe ty \0
M o d e l\
A tl a n ta \B u ild in g s S u rv e y e d
\A T
-1
F o rt M c P h e rs o n
O P
C \A
T -1
F o rt
M c P h e rs o n O
P C
.r v t
/1
/2
:5
:2
A M
FIRE/SMOKE DOOR INSPECTION FLOOR PLAN -
LEVEL 01
E.K. HP
LS0401
VISN 7 ATLANTA
07/31/2018
VISN 7
ATLANTA
100% SUBMITTAL
Note Number Fire Door Note
1 VISIBLE SIGN OF DAMAGE
2 PARTS MISSING OR BROKEN
3 SURFACE HOLES IN DOOR OR FRAME
4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE
4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE
5 FAILED GLAZING AND FRAME INSPECTION
6 SELF-CLOSING DEVICE NOT OPERATIONAL
7 COORDINATOR NOT OPERATIONAL
8 LATCHING HARDWARE NOT OPERATIONAL
9 AUXILIARY HARDWARE INTERFERENCE
10 EDGE CLEARANCE NOT ACCEPTABLE
11 DOOR CLEARANCE NOT ACCEPTABLE
12 SIGNAGE DOES NOT MEET REQUIREMENTS
13 FIELD MODIFICATIONS VOID LABEL
Note Number Fire Smoke Door Note
1 VISIBLE SIGN OF DAMAGE
2 PARTS MISSING OR BROKEN
3 SURFACE HOLES IN DOOR OR FRAME
4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE
4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE
5 FAILED METAL DOOR FRAME INSPECTION
6 FAILDED GLAZING AND FRAME INSPECTION
7 SELF-CLOSING DEVICE NOT OPERATIONAL
8 COORDINATOR NOT OPERATIONAL
9 LATCHING HARDWARE NOT OPERATIONAL
10 AUXILIARY HARDWARE INTERFERENCE
11 EDGE CLEARANCE NOT ACCEPTABLE
12 DOOR CLEARANCE NOT ACCEPTABLE
NORTH ARROW
FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 01
3/32" = 1'-0" l lllllll
O OO
OO OO
KEY NOTES
KEY NOTES
ll llll l l l l l l l l l l l l l lllllllllll l l l l l l l l ll llll l l l l l ll ll l l l l l l l l l l l l l l l l l l l l l l l l l l l l l ll ll l ll ll l llll l l l l l ll llll l l l l
DOOR FAILS INSPECTION TEST
DOOR PASSES INSPECTION TEST
FB1 = FIRE BARRIER 1HR
FB2 = FIRE BARRIER 2HR
FB1/2 = FIRE BARRIER 30 MIN
FSB1 = FIRE / SMOKE BARRIER 1HR
FSB2 = FIRE / SMOKE BARRIER 2HR
SP0 = SMOKE PARTITION NON-RATED
SB0 = SMOKE BARRIER NON-RATED
EHR = EXISTING HAZARDOUS ROOMS
HCO = HEALTH CARE OCCUPANCY
NON-RATED
NON-RATED INTERIOR PARTITION WALL
XXX-XXXX-XX-XXXXX DOOR TAG
97 SF
FIT & DISP.
2A300
288 SF
NOT KNOWN
2A301
129 SF
EYE EXAM
2A302
82 SF
MED
2A303
65 SF
ELEC.
2A304
68 SF
COMM.
2A305
290 SF
GROUP RM
2A306
129 SF
SCREEN
2A307
216 SF
WATER LAB
2A308
98 SF
EXAM RM 1
2A309
104 SF
DOCTOR'S OFF
2A310
349 SF
GROUP RM
2A311
100 SF
EXAM RM 2
2A312
152 SF
PVT MED SPEC
OFF
2A313
100 SF
CHIEF OFF
2A314
100 SF
COMM. NRS
2A315
103 SF
OCCUP. NRS 1
2A316
63 SF
MALE TLT
2A317
102 SF
OCCUP. NRS 2
2A318
63 SF
FEMALE TLT
2A319
102 SF
OCCUP. NRS 3
2A320
99 SF
NCOIC
2A322
120 SF
SEC
2A323
244 SF
CONF
2A324
140 SF
CHIEF NRS
2A325
99 SF
CHIEF WARD
MASTER
2A326
135 SF
DCCS OFF
2A327
135 SF
DEPT. CDR
2A328
93 SF
FEMALE TLT
2A329
180 SF
SEC
2A330
118 SF
MALE TLT
2A331
182 SF
SEC
2A332
163 SF
COMMAND OFF
2A333
27 SF
STG
2A334
112 SF
NCO
2A335
136 SF
MULTI-OFF
2A336
300 SF
COMP RM
2A337
158 SF
MULTI-OFF
2A338
153 SF
STAIR
S2-NO. 1
482 SF
INTERVIEW/FILES
2A339
69 SF
NOT KNOWN
RCC201R
574 SF
CORR
RCC202R
688 SF
CORR
RCC203R
OPEN
TO
BELOW
1,089 SF
MECH RM.
2A000
ROOF BELOW
78 SF
ELEV. (FREIGHT)
E2-NO. 3
712 SF
MECH RM.
2A201
300 SF
CORR
RCC204R
58 SF
ELEV.
(PASSENGER)
E2-NO. 1
58 SF
ELEV.
(PASSENGER)
(ADD. NO. 4)
E2-NO. 2
1,033 SF
CORR
RCC205R
145 SF
STAIR
S2-NO. 3
1,036 SF
MECH RM.
2A200
233 SF
OFFICE
2A100
120 SF
NCOIC
2A101
117 SF
SEC
2A102
203 SF
RECEPTION
2A103
50 SF
FILES
2A104
164 SF
CHIEF, DENTAL
2A105
129 SF
CLERIC
2A106
120 SF
DTR/OTH 14
2A107
120 SF
DTR/OTH 13
2A108
121 SF
DTR/OTH 12
2A109
92 SF
STG
2A110
122 SF
DTR/OTH 11
2A111
355 SF
WAIT
2A112
162 SF
CONSULTATION 3
2A113
122 SF
DTR/OTH 10
2A114
152 SF
X-RAY
2A115
88 SF
STG
2A116
68 SF
DEVEL.
2A117
122 SF
DTR/OTH 9
2A118
92 SF
CLEAN SUPPLY
2A119
121 SF
DTR/OTH 8
2A120
121 SF
DTR 6
2A121
122 SF
DTR/OTH 7
2A122
121 SF
DTR 5
2A123
38 SF
J.C. & SUPP
2A124
158 SF
CONSULTATION 2
2A125135 SF
STAIR
S2-NO. 2
113 SF
DENTAL LOUNGE
2A126
31 SF
DRUG STOR.
2A127
31 SF
CYL. STOR.
2A128
144 SF
STAFF MALE
TLT/LKR
2A129
155 SF
CENTRAL STER.
2A130161 SF
STAFF FEMALE
TLT/LKR
2A131
273 SF
LMT PROS/DENT.
2A132
121 SF
DTR/OTH 4
2A133
120 SF
DTR/OTH 3
2A134
181 SF
CONSULTATION 1
2A135
161 SF
DECONTAM.
2A136
97 SF
STOR
2A138
129 SF
CENTRAL ISSUE
2A139
91 SF
CLEAN SUPPLY
2A140
116 SF
DTR/OTH 2
2A141
117 SF
DTR/OTH 1
2A142
82 SF
MALE PAT
TOILET
2A143
87 SF
FEMALE PAT
TOILET
2A144
82 SF
ELEC.
2A145
77 SF
COMM.
2A146
1,234 SF
CORR
RCC206R
262 SF
WAITING
RCC207R
508-125-02-DRF001
508-125-02-DRF002
508-125-02-DRS001
508-125-02-DRS002 508-125-02-DRS003
508-125-02-DRS004
508-125-02-DRS005 508-125-02-DRS006
4b
11 7
' 6
G ra p h ic S ca le
/2
1'
-0
G ra p h ic S ca le
/3 2"
'-0
' G ra p h ic S ca le
/1 6"
'-0
' G ra p h ic
S ca le
/8
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
/8
1'
-0
' G ra p h ic
S ca le
/2
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
'-0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
VISN 7 LIFE SAFETY SURVEY AND
DRAWING UPDATE, TASK ORDER
#13
GS-10F-0347P
Elijah Knight, PE
R R o m a n y k C o n s u lt in g \R
C C
A E
C
C o n s u lt in g \0
P ro je c ts
\V
IS
N
\L if e
S a fe ty \0
M o d e l\
A tl a n ta \B u ild in g s S u rv e y e d
\A T
-1
F o rt M c P h e rs o n
O P
C \A
T -1
F o rt
M c P h e rs o n O
P C
.r v t
/1
/2
:5
:2
A M
FIRE/SMOKE DOOR INSPECTION FLOOR PLAN -
LEVEL 02
E.K. HP
LS0402
VISN 7 ATLANTA
07/31/2018
VISN 7
ATLANTA
100% SUBMITTAL
Note Number Fire Door Note
1 VISIBLE SIGN OF DAMAGE
2 PARTS MISSING OR BROKEN
3 SURFACE HOLES IN DOOR OR FRAME
4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE
4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE
5 FAILED GLAZING AND FRAME INSPECTION
6 SELF-CLOSING DEVICE NOT OPERATIONAL
7 COORDINATOR NOT OPERATIONAL
8 LATCHING HARDWARE NOT OPERATIONAL
9 AUXILIARY HARDWARE INTERFERENCE
10 EDGE CLEARANCE NOT ACCEPTABLE
11 DOOR CLEARANCE NOT ACCEPTABLE
12 SIGNAGE DOES NOT MEET REQUIREMENTS
13 FIELD MODIFICATIONS VOID LABEL
Note Number Fire Smoke Door Note
1 VISIBLE SIGN OF DAMAGE
2 PARTS MISSING OR BROKEN
3 SURFACE HOLES IN DOOR OR FRAME
4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE
4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE
5 FAILED METAL DOOR FRAME INSPECTION
6 FAILDED GLAZING AND FRAME INSPECTION
7 SELF-CLOSING DEVICE NOT OPERATIONAL
8 COORDINATOR NOT OPERATIONAL
9 LATCHING HARDWARE NOT OPERATIONAL
10 AUXILIARY HARDWARE INTERFERENCE
11 EDGE CLEARANCE NOT ACCEPTABLE
12 DOOR CLEARANCE NOT ACCEPTABLE
NORTH ARROW
FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 02
3/32" = 1'-0"
| Sheets |
| G-04 - COVER |
| G-04X1 - GENERAL SHEET |
| G-04X2 - GENERAL SHEET |
| LS040B - FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - BASEMENT |
| LS0401 - FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 01 |
| LS0402 - FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 02 |
File details come from the government source that posted it. Updated .