04 Series DOORS - 100 AT-128 Fort McPherson Homeless Program.pdf
PDF 1 MB Posted
- Attached to
- Fire Sprinkler Testing Federal contract opportunity
- Solicitation number
- 36C24724Q0269
About this file
This document package includes life safety drawings and a fire sprinkler testing solicitation. The drawings depict an existing VA medical center building and detail fire and smoke barriers, occupancy classifications, egress components, and fire door inspections. The solicitation seeks quarterly fire sprinkler inspections and testing in accordance with NFPA 25. Offerors must have a minimum of five years experience performing sprinkler inspections and testing for medical facilities. The period of performance is one base year with four option years. The location of work is VISN 7 facilities in Alabama, Florida, Georgia, and South Carolina. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 7 is the contracting agency.
View the file
Other files for this federal contract opportunity
Show all 38
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INDEX OF DRAWINGSVICINITY MAP PROJECT TEAMBUILDING SUMMARYANNOTATION DRAWING SYMBOLS
OWNER
Department of Veterans Affairs Tuscaloosa VA Medical Center 3701 Loop Road East Tuscaloosa AL 35404-5088
PROJECT MANAGER
Romanyk Consulting 3308 Preston Road, Suite 350-164 Plano, TX 75093
Sherri Mitchell, Contracting Officer Sherri.mitchell@va.gov
334-272-4670, ext 2238
Joshua Leow, COR Joshua.leow@va.gov
Elijah Knight, PE, MSEM elijah.knight@romanykconsulting.com
855-424-3838 ext.323 405-640-1586 cell
MECHANICAL ENGINEER
PROJECT ARCHITECT
John Slattery, RA john.slattery@romanykconsulting.com
855-424-3838 ext.336 918-430-6020 cell
Brad Cain, PE brad.cain@romanykconsulting.com
855-424-3838 ext.335 864-908-8304 cell
Romanyk Consulting 3308 Preston Road, Suite 350-164 Plano, TX 75093
Romanyk Consulting 3308 Preston Road, Suite 350-164 Plano, TX 75093
LIFE SAFETY ENGINEER
Frank Van Overmeiren fvanovermeiren@fpc-consultants.com
317-486-5188 ext.13
FP&C Consultants, Inc.
1520 Main Street Indianapolis, IN 46224
ROOM NAME
ROOM NAME / NUMBER
NORTH ARROW
NORTH ARROW WITH TRUE
NORTH INDICATION
Name Elevation
FLOOR LEVEL &
NAME
SHEET KEYNOTE1
XXX-XXXX-XX-XXXXX DOOR TAG
1 SHEET KEYNOTE
XXX-XXX-XX-XXXXX
WALL
PENETRATION TAG
XXX-XXX-XX-DPXXX DAMPER TAG
The A/E team, including architects, engineers, surveyors, and professional consultants shall survey and inspect the following VISN 7 VA Medical Center for Life safety deficiencies according to 2015 NFPA 101 Life Safety Code and Joint Commission Standard LS.01.01.01, EP 2 and provide comprehensive as-built Life Safety Plans (LSP)
SCOPE OF WORK SUMMARY:
• Tuskegee
• Montgomery
Team shall provide a list of discrepancies based off their findings and provide recommended methods for corrections. Team shall also update the facilities current life/fire safety plans to reflect existing as-built conditions based off the survey. Team shall also survey the facility to locate existing fire dampers and provide accurate as-built drawings.
A/E shall assume all areas of the campus are, and must remain fully operational, and that inspections may require coordination with the Owner for after-hours access, accompanied access and protected access (for medically sensitive areas, etc.), and shall include all such work as part of the A/E Scope of Work (SOW).
Life Safety inspection shall include the following. Inspecting all fire walls (including doors, door frames, and hardware) smoke walls, locations of all fire extinguishers, smoke detectors, smoke compartments, and exit signs.
A/E shall reference NFPA 101 and other NFPA applicable codes and provide the follow for each deliverable.
• Columbia
• Atlanta
• Augusta UD
• Augusta DD
• Dublin
• Charleston
FIRE/SMOKE DOORS - DRAWING LIST
LS0101A
LEVEL
DISCIPLINE
SECTION LETTER
WITHIN LEVEL
SERIES
01 SERIES = TJC DRAWINGS
02 SERIES = WALL PENETRATION DEFICIENCY DRAWINGS
03A SERIES = LIFE SAFETY DRAWINGS
03B SERIES = EXIT AND OCCUPANCY DRAWINGS
04 SERIES = FIRE/SMOKE DOOR DRAWINGS
05 SERIES = FIRE/SMOKE DAMPER DRAWINGS
' 6
G ra p h ic S ca le
/2
1'
-0
G ra p h ic S ca le
/3 2"
'-0
' G ra p h ic S ca le
/1 6"
'-0
' G ra p h ic
S ca le
/8
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
/8
1'
-0
' G ra p h ic
S ca le
/2
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
'-0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
VISN 7 LIFE SAFETY SURVEY AND
DRAWING UPDATE, TASK ORDER
#13
GS-10F-0347P
Elijah Knight, PE
VISN 7 LIFE SAFETY SURVEY AND DRAWING UPDATE
BPA ORDER NO. VA247-14-A-0028 - TASK ORDER #13
EE
ES
S
OF
M
R C
D
T
T T
II
N
U A
A A
V
RAP
M
N
T
T
OF
E E
D
R S
I
FA
A
N T
S R
F
AEE
2017 LIFE SAFETY DOCUMENTATION
FINAL
Contract: GS-10F-0347P Task Order: VA247-17-F-2259
R R o m a n y k C o n s u lt in g \R
C C
A E
C
C o n s u lt in g \0
P ro je c ts
\V
IS
N
\L if e
S a fe ty \0
M o d e l\
A tl a n ta \B u ild in g s S u rv e y e d
\A T
-1
F o rt M c P h e rs o n
H o m e le s s P ro g ra m \A
T -1
F o rt
M c P h e rs o n H o m e le s s P ro g ra m
.r v t
/1
/2
:0
:0
A
M
COVER
E.K. HP
G-04
VISN 7 ATLANTA
07/31/2018
VISN 7
ATLANTA
Building 128 - FT McPHERSON - HOMELESS PROGRAM
100% SUBMITTAL
04 - GENERAL
G-04 COVER
G-04X1 GENERAL SHEET
G-04X2 GENERAL SHEET
04 - FIRE/SMOKE DOOR
LS0401 FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 01
LS0402 FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 02
Grand total: 5
FIRE/SMOKE DOORS
Prepared for:
100% Submission for
Fort McPherson VA Clinic Atlanta, GA
Revisions: Date:
l lllllll
OO OO O O ∅ ∅∅ ∅ ∅
' 6
G ra p h ic S ca le
/2
1'
-0
G ra p h ic S ca le
/3 2"
'-0
' G ra p h ic S ca le
/1 6"
'-0
' G ra p h ic
S ca le
/8
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
/8
1'
-0
' G ra p h ic
S ca le
/2
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
'-0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
VISN 7 LIFE SAFETY SURVEY AND
DRAWING UPDATE, TASK ORDER
#13
GS-10F-0347P
Elijah Knight, PE
R R o m a n y k C o n s u lt in g \R
C C
A E
C
C o n s u lt in g \0
P ro je c ts
\V
IS
N
\L if e
S a fe ty \0
M o d e l\
A tl a n ta \B u ild in g s S u rv e y e d
\A T
-1
F o rt M c P h e rs o n
H o m e le s s P ro g ra m \A
T -1
F o rt
M c P h e rs o n H o m e le s s P ro g ra m
.r v t
/1
/2
:0
:0
A
M
GENERAL SHEET
E.K. HP
G-04X1
VISN 7 ATLANTA
07/31/2018
VISN 7
ATLANTA
100% SUBMITTAL
Revisions: Date:
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND
STAIRWELLS OF 4 OR MORE STORIES.
WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.
DUCTS: ALL DUCT PENETRATIONS ARE PROTECTED BY FIRE DAMPERS.
PENETRATIONS: ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP
MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL
PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE
WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON
THE TOP OF THE FLOOR.
DOORS: ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).
11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT AT
LEAST ANNUALLY (NFPA 80 5.2.4.1)
2-HOUR FIRE BARRIER
THIS APPLIES TO 1-HOUR FIRE RATED OCCUPANCY SEPERATIONS, HAZARDOUS ROOM
ENCLOSURES AND STAIRWELLS 3 STORIES OR LESS.
WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.
DUCTS: STEEL DUCT PENETRATIONS NOT REQUIRED TO BE PROTECTED BY
FIRE DAMPERS.
PENETRATIONS: ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP
MATERIALS FOR PROTECTING 1-HOUR WALL ASSEMBLIES. WALL
PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE
WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON
THE TOP OF THE FLOOR.
DOORS*: ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 3/4 OR 1-HOUR DOOR (NFPA 80 4.3.1)*
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).
11.PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT
AT LEAST ANNUALLY (NFPA 80 5.2.4.1)
* 1-HOUR DOORS ARE REQUIRED IN STAIRWELLS THAT ARE 3
STORIES OR LESS.
1-HOUR FIRE BARRIER
WALL: IF THE HAZARDOUS ROOM HAS A SUSPENDED CEILING CONSTRUCTED
TO LIMIT TRANSFER OF SMOKE, THE WALL HAS NO FIRE RESISTANCE
RATING AND MAY TERMINATE AT THE CEILING. IF THE ROOM DOES NOT
HAVE A SUSPENDED CEILING, THE WALL HAS NO FIRE RESISTANCE
RATING AND SHALL EXTEND TO THE DECK ABOVE.
DUCTS: STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED
BY FIRE DAMPERS OR SMOKE DAMPERS.
PENETRATIONS: SEALED WITH NON-FIRE-RATED MATERIALS TO BE RESISTIVE. USE OF
LISTED FIRESTOP MATERIALS IS NOT REQUIRED.
DOORS: EXISTING HAZARDOUS ROOMS:
1. NON-LABELED FRAME (NFPA 101 19.3.7.9)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 19.3.7.6)
3. MAXIMUM 1296 SQ. IN. WINDOW (NFPA 101 19.3.6.3.17)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 19.3.6.3.5)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 19.3.2.1.3)
6. MAXIMUM 1/8" GAP (NFPA 101 19.3.6.3.1)
7. MAXIMUM 1" UNDERCUT (NFPA 101 19.3.6.3.4)
8. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 19.3.2.1.2)
9. SWING IN ANY DIRECTION
10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST
ANNUALLY (NFPA 105 5.2.1.1)
SMOKE RESISTIVE HAZARDOUS ROOMS
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS
OF 4 OR MORE STORIES. THIS COMBINATION WALL IS WHERE A PORTION OF THE 2-HOUR
RATED WALL IS ALSO PART OF THE SMOKE WALL.
WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.
DUCTS: ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE
AND SMOKE DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED
WHERE ADJACENT SMOKE COMPARTMENTS ARE PROTECTED BY
QUICK RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.
PENETRATIONS: ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP
MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL
PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE
WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON
THE TOP OF THE FLOOR.
DOORS: ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)
10.SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).
11.PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT
AT LEAST ANNUALLY (NFPA 80 5.2.4.1)
2-HOUR FIRE AND SMOKE BARRIER
SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR
DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS OF
MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND THE
BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE
REQUIRED TO BE OF 1 HOUR FIRE RESISTANCE RATING. (NFPA 101, 18.3.2.7.5) SMOKE ZONE
BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED TO BE OF
A 1/2 HOUR FIRE RESISTANCE RATING (NFPA 101, 19.3.7.3)
WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.
DUCTS: ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE DAMPERS.
SMOKE DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE
COMPARTMENTS ARE PROTECTED BY QUICK RESPONSE SPRINKLERS
THROUGHOUT EACH COMPARTMENT.
PENETRATIONS: ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS
FOR PROTECTING 1-HOUR FIRE AND SMOKE WALL ASSEMBLIES.
PENETRATIONS ARE TO BE FILLED ON BOTH SIDES OF THE WALL.
DOORS: ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:
1. NON-LABELED FRAME (NFPA 101 18.3.7.6)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 18.3.7.6)
3. MAXIMUM 1296 SQ. IN. WINDOW (NFPA 80 4.4.4)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18.3.7.8)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18.3.7.8)
6. MAXIMUM 1/8" GAP (NFPA 101 18.3.7.6.)
7. MAXIMUM 1" UNDERCUT (NFPA 101 19.3.6.3.4)
8. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 18.3.7.6)
9. SWING IN DIRECTION OPPOSITE OF EACH OTHER (NFPA 101 18.3.7.6)
10.SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY
(NFPA 105 5.2.1.1)
SMOKE ZONE BARRIERS
IF THE SMOKE COMPARTMENT IS SPRINKLERED, THE WALL SHALL FORM A BARRIER TO LIMIT THE TRANSFER OF SMOKE. THE WALL HAS NO REQUIRED FIRE RESISTANCE RATING AND MAY TERMINATE AT A CEILING CONSTRUCTED TO LIMIT TRANSFER OF SMOKE. DOORS ARE MANUALLY CLOSED IN AN EMERGENCY NFPA 101, 18.3.6.2 & 19.3.6.2
IF THE SMOKE COMPARTMENT IS NOT SPRINKLERED, THE WALL SHALL BE CONTINUOUS FROM THE FLOOR TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK ABOVE. CORRIDOR WALL SHALL HAVE A MINIMUM 1/2 HOUR FIRE RESISTANCE RATING. DOORS ARE MANUALLY CLOSED IN AN EMERGENCY NFPA 101 19.3.6.2
DOORS: DOORS THAT ARE NOT PART OF A RATED WALL:
1. NON-LABELED FRAME (NFPA 101 18.3.6.3.1, 19.3.6.3 & 19.3.6.3.3)
2. NON-RATED DOORS PERMITTED IF SPRINKLERED (NFPA 101 18.3.6.3.1, 19.3.6.3.2(2))
3. 20-MINUTE OR SOLID WOOD CORE DOOR IF NOT SPRINKLERED (NFPA 101 19.3.6.3.1)
4. POSITIVE LATCHING EXCEPT TOILETS, SHOWER AND SINK
CLOSETS (NFPA 101 18.3.6.3.6 & 19.3.6.3.6)
5. SELF-CLOSING NOT REQUIRED (NFPA 101 19.3.6.3.11)
6. NO MAXIMUM GAP (NFPA 101 18.3.6.3.1 & 19.3.6.3.3)
7. MAXIMUM 1" UNDERCUT (NFPA 101 18.3.6.3.1 & 19.3.6.3.4)
8. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 18/19.3.6.3.12)
9. TRANSFER GRILLS NOT PERMITTED EXCEPT TOILETS, SHOWER AND SINK CLOSETS
(NFPA 101 18/19.3.6.4)
10. SWING IN ANY DIRECTION
11. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105 5.2.1.1)
HEALTH CARE OCCUPANCY CORRIDORS
NOTE: ALL CODE REFERENCES ARE PER THE 2015 EDITION OF NFPA 101 LIFE SAFETY CODE AND THE OTHER APPLICABLE CODES. FEDERAL FACILITIES FOLLOW 2015 LIFE SAFETY CODE.
FORMER DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER ZONE.
BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY THE FIRE
DEPARTMENT PER SECTION 15.7.4.3 OF NFPA 99-2015 EDITION AND PRIVATE MODE AUDIBLE
REQUIREMENTS OF SECTION 18.4:4 OF NFPA 72-2016 EDITION.
WALL: WALL EXTENDS FROM FLOOR TO SUSPENDED CEILING OR DECK ABOVE.
DUCTS: NO MINIMUM REQUIREMENTS.
PENETRATIONS: NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A
SUSPENDED CEILING. PENETRATIONS BELOW A SUSPENDED CEILING
OR DECK SEALED WITH NON-FIRE-RATED MATERIALS TO BE SMOKE
RESISTIVE.
DOORS: NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC
CLOSING IN AN EMERGENCY.
NON-RATED SMOKE PARTITION
SUITES
HEALTHCARE AREA OPEN TO CORRIDOR WITH 24/7 SUPERVISION - NO SMOKE DETECTION REQUIRED.
HEALTHCARE AREA OPEN TO CORRIDOR - SMOKE DETECTION PROVIDED.
(COLOR #3) (COLOR #4) (COLOR #230)
(COLOR #1) (COLOR #6) (COLOR #30)
(COLOR #2)
(COLOR #2)
(COLOR #3)
' 6
G ra p h ic S ca le
/2
1'
-0
G ra p h ic S ca le
/3 2"
'-0
' G ra p h ic S ca le
/1 6"
'-0
' G ra p h ic
S ca le
/8
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
/8
1'
-0
' G ra p h ic
S ca le
/2
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
'-0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
VISN 7 LIFE SAFETY SURVEY AND
DRAWING UPDATE, TASK ORDER
#13
GS-10F-0347P
Elijah Knight, PE
R R o m a n y k C o n s u lt in g \R
C C
A E
C
C o n s u lt in g \0
P ro je c ts
\V
IS
N
\L if e
S a fe ty \0
M o d e l\
A tl a n ta \B u ild in g s S u rv e y e d
\A T
-1
F o rt M c P h e rs o n
H o m e le s s P ro g ra m \A
T -1
F o rt
M c P h e rs o n H o m e le s s P ro g ra m
.r v t
/1
/2
:0
:0
A
M
GENERAL SHEET
E.K. HP
G-04X2
VISN 7 ATLANTA
07/31/2018
VISN 7
ATLANTA
100% SUBMITTAL
Revisions: Date:
APPLICABLE CODES AND STANDARDS:
1. THE BUILDING WAS DESIGNED TO THE 1960 EDITION OF NFPA 101, LIFE SAFETY CODE.
2. THE 1960 PUBLIC BUILDING AMENDMENT ACT (PL100-678) REQUIRES ALL FEDERAL AGENCIES TO FOLLOW
THE LATEST EDITIONS OF NATIONALLY RECOGNIZED FIRE AND LIFE SAFETY CODES. THE VA HAS ADOPTED THE NATIONAL FIRE CODES PUBLISHED BY THE NATIONAL FIRE PROTECTION ASSOCIATION. LIFE SAFETY REQUIREMENTS ARE SPECIFICALLY ADDRESSED IN THE 2018 EDITION OF NFPA 101, LIFE SAFETY CODE.
3. ALL NEW CONSTRUCTION OR BUILDING RENOVATIONS ARE REQUIRED TO COMPLY WITH THE LATEST EDITION OF NFPA 101 OR IT'S REFERENCED STANDARDS. EXISTING BUILDING CONDITIONS ARE REQUIRED TO COMPLY WITH THE APPLICABLE CODES OR STANDARDS AT THE TIME OF BUILDING DESIGN AND THE APPLICABLE PROVISIONS FOR EXISTING BUILDINGS IN CURRENT EDITIONS OF APPLICABLE
CODES AND STANDARDS.
4. OTHER NFPA CODES AND STANDARDS:
A. NFPA 10 - PORTABLE FIRE EXTINGUISHERS, 2018 EDITION.
B. NFPA 13 - SPRINKLER SYSTEMS, 2016 EDITION.
C. NFPA 14 - STANDPIPE SYSTEMS, 2016 EDITION.
D. NFPA 20 - FIRE PUMPS, 2016 EDITION
E. NFPA 70 - NATIONAL ELECTRIC CODE, 2017 EDITION.
F. NFPA 72 - NATIONAL FIRE ALARM CODE, 2016 EDITION.
G. NFPA 75 - ELECTRONIC COMPUTER EQUIPMENT, 2017 EDITION.
H. NFPA 80 - FIRE DOORS, 2016 EDITION.
I. NFPA 90A&B - HEATING AND AIR CONDITIONING SYSTEMS, 2018 EDITION.
J. NFPA 96 - COMMERCIAL COOKING EQUIPMENT, 2017 EDITION.
K. NFPA 99 - HEALTH CARE FACILITIES CODE, 2018 EDITION.
L. NFPA 105 - SMOKE DOORS, 2016 EDITION.
M. NFPA 110 - EMERGENCY POWER SYSTEMS, 2016 EDITION.
N. NFPA 241 - CONSTITUTION AND DEMOLITION, 2013 EDITION.
PENETRATIONS:
1. PRIOR TO THE EARLY 1990'S, THE STANDARD INDUSTRY PRACTICE FOR THE SEALING OF PENETRATIONS WAS TO
USE THE SAME CONSTRUCTION MATERIALS AS HOW THE WALL/FLOOR WAS CONSTRUCTED. CONCRETE PATCH WAS USED FOR CONCRETE FLOORS. MORTAR JOINT COMPOUND WAS USED FOR MASONRY WALLS. GYPSUM
PATCH COMPOUND WAS USED USED FOR GYPSUM WALLS.
2. PRIOR TO THE EARLY 1990'S, THE MANUFACTURES PUBLISHED INSTRUCTIONS FOR FIRE RESISTIVE WALL AND FLOOD CONSTRUCTION REQUIRED THE USE OF THE SAME CONSTRUCTION MATERIALS AS HOW THE WALL/FLOOR
WAS CONSTRUCTED TO SEAL PENETRATIONS.
3. THE FIRST LISTINGS OF FIRESTOP MATERIALS WAS IN 1991. THE FIRST CODE REQUIREMENTS TO UTILIZE LISTED
FIRESTOP MATERIALS OCCURRED IN 1992 EDITIONS OF CODES AND STANDARDS.
4. ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR PROTECTING THE REQUIRED RATING
OF THE WALL ASSEMBLY.
5. EXISTING PENETRATIONS SEALED WITH THE SAME CONSTRUCTION MATERIAL AS THE WALL/FLOOR, MAY REMAIN
AS AN EXISTING PREVIOUSLY APPROVED CONSTRUCTION METHOD.
6. EXISTING PENETRATIONS THAT REQUIRE REPAIR OR REPLACEMENT REQUIRE THE USE OF LISTED FIRESTOP
MATERIALS.
FIRE SPRINKLER SYSTEM:
1. THE COMBINATION STANDPIPE AND FIRE SPRINKLER SYSTEM WAS DESIGNED TO THE 2016 EDITION OF NFPA 13.
2. QUICK RESPONSE TYPE SPRINKLERS ARE INSTALLED THROUGHOUT MOST OF THE BUILDING. STANDARD
RESPONSE TYPE SPRINKLERS ARE INSTALLED IN THE ELEVATOR MACHINE ROOMS.
3. SPRINKLERS WERE INSTALLED IN LIGHT HAZARD AREAS INCLUDING; CORRIDORS, OFFICES, PATIENT CARE AND
PATIENT SLEEPING ROOMS AT LIGHT HAZARD 0.10 GPM/1500 SQ. FT. DENSITY.
4. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP I AREAS INCLUDING; LABORATORIES (WITHOUT
FLAMMABLE LIQUIDS), MECHANICAL EQUIPMENT ROOMS, ELECTRICAL SWITCH GEAR ROOMS, REPAIR SHOPS AND
STORAGE ROOMS UNDER 250 SQ. FT. AT A 0.15 GPM/1500 SQ. FT. DENSITY.
5. SPRINKLERS WERE INSTALLED IN ORDINARY HAZARD GROUP II AREAS INCLUDING GENERAL STORAGE ROOMS OVER 250 SQ. FT. AND LABORATORIES (WITH THE USE OF FLAMMABLE LIQUIDS) AT A 0.20 GPM/1500 SQ. FT.
DENSITY.
FIRE ALARM SYSTEM:
1. THE FIRE ALARM SYSTEM WAS DESIGNED TO THE 2013 EDITION OF NFPA 72, NATIONAL FIRE ALARM CODE.
2. PRIVATE MODE BUILDING OCCUPANT NOTIFICATION IS INSTALLED PER SECTIONS 19.3.4.3.1 AND 9.6.3.6.3 OF NFPA
101-2015 EDITION.
3. PRIVATE MODE AUDIBLE DEVICES (SPEAKERS) ARE INSTALLED IN CORRIDORS AND LARGER ROOMS OR SUITES
PER SECTION 18.4.4.1 OF NFPA 72-2016 EDITION.
4. PRIVATE MODE VISIBLE DEVICES (STROBES) ARE INSTALLED AT REDUCED QUANTITY AND SPACING PER SECTION
18.6 OF THE NFPA 72-2016 EDITION.
5. STROBE CIRCUITS ARE REQUIRED TO BE SYNCHRONIZED IN ACCORDANCE WITH SECTION 18.5.5.4.2 OF NFPA
72-2016 EDITION.
SUITES:
1. SUITES ARE UTILIZED TO ILLUSTRATE AREAS WITH THE SAME FUNCTION, USE OF HALLWAYS OR AISLES AND THE
END OF PUBLIC EXIT CORRIDORS. NO EXIT SIGNS OUTSIDE OF THE SUITE DIRECT OCCUPANTS INTO A SUITE TO
REACH AN EXIT.
2. HEALTH CARE OCCUPANCY SUITES ARE REGULATED BY FUNCTION AND SIZE.
3. HEALTH CARE OCCUPANCY PATIENT SLEEPING SUITES:
A. SINGLE EXIT SUITE - 1,000 SQ. FT. (NFPA 101 -19.2.5.7.2.2)
B. MULTI EXIT SUITE - 5,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.A)
C. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS OR COMPLETE SMOKE DETECTION - 7,500 SQ.
FT. (NFPA 101 - 19.2.5.7.2.3.B)
D. MULTI EXIT SUITE WITH DIRECT VISUAL SUPERVISION, QUICK RESPONSE SPRINKLERS AND COMPLETE
SMOKE DETECTION - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.2.3.C)
4. PATIENT CARE NON - SLEEPING SUITES:
A. SINGLE EXIT SUITE - 2,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.1.B)
B. MULTI EXIT SUITE - 10,000 SQ. FT. (NFPA 101 - 19.2.5.7.3.2)
C. MULTI EXIT SUITE WITH STANDARD RESPONSE SPRINKLERS AND COMPLETE SMOKE DETECTION OR QUICK
RESPONSE SPRINKLERS - 12,500 SQ. FT. (NFPA 101 - 19.2.5.7.3.2.A)
D. MULTI EXIT SUITE WITH QUICK RESPONSE SPRINKLERS AND COMPLETE SMOKE DETECTION (NFPA 101 -
19.2.5.7.3.2.B)
5. HEALTH CARE OCCUPANCY NON - PATIENT - CARE SUITES FOLLOW THE TRAVEL DISTANCE REQUIREMENTS
AS LISTED IN TABLE A.7.6 OF NFPA 101.
6. SUITES IN OTHER OCCUPANCIES ARE NOT REGULATED IN SIZE BUT STILL FOLLOW THE TRAVEL DISTANCE
REQUIREMENTS AS LISTED IN TABLE A.7.6 OF NFPA 101.
BUILDING # FLOOR
HEALTH CARE
OCCUPANCY
TOTAL
508C 1 49,031 0 22,513 0 71,544
AMBULATORY HEALTH
CARE OCCUPANCY
BUSINESS
OCCUPANCY
INDUSTRIAL
OCCUPANCY
508ASCA 2 0 0 56,228 0 56,228
508ASCA 1 0 0 56,573 0 56,573
125 2 0 0 22,258 0 22,258
125 1 0 0 41,126 0 41,126
128 2 0 0 8,723 0 8,723
128 1 0 0 8,723 0 8,723
SUB TOTAL 0 0 17,446 0 17,446
129 2 0 0 8,696 0 8,696
129 1 0 0 8,692 0 8,692
SUB TOTAL 0 0 17,388 0 17,388
130 1 0 0 8,721 0 8,721
131 2 0 0 0 0 9,517
SUB TOTAL 0 0 8,721 0 17,442
131 GROUND 0 0 9,516 0 9,516
SUB TOTAL 0 0 9,516 0 28,551
GRAND TOTAL 49,031 0 263,657 0 340,444
OCCUPANCY TABLE
DORMITORY
OCCUPANCY
9,517
8,721
19,035
27,756
SUB TOTAL
SUB TOTAL 0 0 112,801 0 112,8010
125 BASEMENT 0 0 11,888 0 11,8880
SUB TOTAL 0 0 75,272 0 75,2720
130 2 0 0 0 0 8,7218,721
131 1 0 0 0 0 9,5189,518
49,031 0 22,513 0 71,5440 l ll l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l ll l ll l l l l l l l
LEGEND
l lllllll
O OO
OO OO
KEY NOTES
KEY NOTES
278 SF
EGRESS STAIR
1A001
185 SF
EGRESS STAIR 2
1A002
204 SF
EGRESS STAIR
1A003
95 SF
ELEV SHAFT
RCC101C
352 SF
ENTRY
1A100 421 SF
PAT CORR
1A100B
560 SF
PAT CORR
1A100C
54 SF
PAT CORR
1A100D
387 SF
WAIT
1A101
66 SF
RECEPTION
1A102
73 SF
INTAKE
CONSULT RM
1A103
64 SF
SECURITY
1A104
120 SF
CONSULT RM
1A105
114 SF
CONSULT RM
1A106
113 SF
CONSULT RM
1A107 123 SF
CONSULT RM
1A108
132 SF
PSYCHIATRIST'S
OFF
1A109
131 SF
SUPV'S OFF
1A110
131 SF
SUPV'S OFF
1A111
132 SF
SUPV'S OFF
1A112
95 SF
STOR
1A113
136 SF
WOMEN'S STAFF TLT
1A114
127 SF
DATA CLO
1A115
124 SF
MEN'S STAFF TLT
1A116
715 SF
WRKRM
1A117
301 SF
WRKRM
1A118
82 SF
ELEV MACH
ROOM
1A119
79 SF
ADA MEN'S
ROOM
1A120
106 SF
ADA WOMEN'S
RM
1A121
72 SF
HAC
1A122
386 SF
STOR
1A141
302 SF
MECH RM
1A125
124 SF
DATA CLO
1A126
217 SF
PLUMBING/FIRE PROTECTION RM
1A127
247 SF
GROUP RM
1A128
115 SF
OFF / CONSULT
1A129
111 SF
OFF / CONSULT
1A130
142 SF
ELEC RM
1A131
DN
178 SF
CONNECTING
CORR
RCC101R
508-128-01-DRF001
508-128-01-DRF002
508-128-01-DRF003
508-128-01-DRF004
508-128-01-DRS001
508-128-01-DRS002
508-128-01-DRS003
3 10
DOOR FAILS INSPECTION TEST
DOOR PASSES INSPECTION TEST
FB1 = FIRE BARRIER 1HR
FB2 = FIRE BARRIER 2HR
FB1/2 = FIRE BARRIER 30 MIN
FSB1 = FIRE / SMOKE BARRIER 1HR
FSB2 = FIRE / SMOKE BARRIER 2HR
SP0 = SMOKE PARTITION NON-RATED
SB0 = SMOKE BARRIER NON-RATED
EHR = EXISTING HAZARDOUS ROOMS
HCO = HEALTH CARE OCCUPANCY
NON-RATED
NON-RATED INTERIOR PARTITION WALL
XXX-XXXX-XX-XXXXX DOOR TAG
' 6
G ra p h ic S ca le
/2
1'
-0
G ra p h ic S ca le
/3 2"
'-0
' G ra p h ic S ca le
/1 6"
'-0
' G ra p h ic
S ca le
/8
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
/8
1'
-0
' G ra p h ic
S ca le
/2
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
'-0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
VISN 7 LIFE SAFETY SURVEY AND
DRAWING UPDATE, TASK ORDER
#13
GS-10F-0347P
Elijah Knight, PE
R R o m a n y k C o n s u lt in g \R
C C
A E
C
C o n s u lt in g \0
P ro je c ts
\V
IS
N
\L if e
S a fe ty \0
M o d e l\
A tl a n ta \B u ild in g s S u rv e y e d
\A T
-1
F o rt M c P h e rs o n
H o m e le s s P ro g ra m \A
T -1
F o rt
M c P h e rs o n H o m e le s s P ro g ra m
.r v t
/1
/2
:0
:0
A
M
FIRE/SMOKE DOOR INSPECTION FLOOR PLAN -
LEVEL 01
E.K. HP
LS0401
VISN 7 ATLANTA
07/31/2018
VISN 7
ATLANTA
100% SUBMITTAL
NORTH ARROW
FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 01
1/8" = 1'-0"
Note Number Fire Door Note
1 VISIBLE SIGN OF DAMAGE
2 PARTS MISSING OR BROKEN
3 SURFACE HOLES IN DOOR OR FRAME
4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE
4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE
5 FAILED GLAZING AND FRAME INSPECTION
6 SELF-CLOSING DEVICE NOT OPERATIONAL
7 COORDINATOR NOT OPERATIONAL
8 LATCHING HARDWARE NOT OPERATIONAL
9 AUXILIARY HARDWARE INTERFERENCE
10 EDGE CLEARANCE NOT ACCEPTABLE
11 DOOR CLEARANCE NOT ACCEPTABLE
12 SIGNAGE DOES NOT MEET REQUIREMENTS
13 FIELD MODIFICATIONS VOID LABEL
Note Number Fire Smoke Door Note
1 VISIBLE SIGN OF DAMAGE
2 PARTS MISSING OR BROKEN
3 SURFACE HOLES IN DOOR OR FRAME
4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE
4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE
5 FAILED METAL DOOR FRAME INSPECTION
6 FAILDED GLAZING AND FRAME INSPECTION
7 SELF-CLOSING DEVICE NOT OPERATIONAL
8 COORDINATOR NOT OPERATIONAL
9 LATCHING HARDWARE NOT OPERATIONAL
10 AUXILIARY HARDWARE INTERFERENCE
11 EDGE CLEARANCE NOT ACCEPTABLE
12 DOOR CLEARANCE NOT ACCEPTABLE
l ll l l l l l l l l l l l l l
LEGEND
l lllllll
O OO
OO OO
KEY NOTES
KEY NOTES
629 SF
STAFF MEETING/GROUP RM
2A219
120 SF
WOMEN'S RM
2A218
109 SF
ADA TLT
2A217
139 SF
MEN'S RM
2A216
239 SF
PAT CORR
2A200D
318 SF
CLASSRM
2A220
424 SF
DEDICATED COMP CLASSRM
2A221
277 SF
EGRESS STAIR
RCC201R
151 SF
EGRESS STAIR 2
RCC203R 168 SF
EGRESS STAIR
RCC202R
407 SF
PAT CORR
2A200C
115 SF
ELEC RM
2A222
106 SF
ELEV SHAFT
RCC205C
79 SF
HAC
2A215
220 SF
PAT CORR
2A200A
71 SF
STOR
2A223
427 SF
STAFF CORR
2A200B
348 SF
MECH RM
2A214
187 SF
BRK RM
2A201
89 SF
DEDICATED
CUBICLE
2A202
151 SF
SUPV'S OFF
2A203
111 SF
SUPV'S OFF
2A204
137 SF
SUPV'S OFF
2A205
108 SF
SUPV'S OFF
2A206
1,342 SF
WRKRM
2A211
91 SF
STOR
2A207
136 SF
WOMEN'S STAFF TLT
2A208
126 SF
DATA CLO
2A209
125 SF
MEN'S STAFF TLT
2A210
142 SF
SUPV'S OFF
2A212
138 SF
WRKRM
2A213
DN
178 SF
CONNECTING
CORR
RCC204R
508-128-02-DRS001
508-128-02-DRS002508-128-02-DRF001
508-128-02-DRF002
508-128-02-DRF003
508-128-02-DRF004
DOOR FAILS INSPECTION TEST
DOOR PASSES INSPECTION TEST
FB1 = FIRE BARRIER 1HR
FB2 = FIRE BARRIER 2HR
FB1/2 = FIRE BARRIER 30 MIN
FSB1 = FIRE / SMOKE BARRIER 1HR
FSB2 = FIRE / SMOKE BARRIER 2HR
SP0 = SMOKE PARTITION NON-RATED
SB0 = SMOKE BARRIER NON-RATED
EHR = EXISTING HAZARDOUS ROOMS
HCO = HEALTH CARE OCCUPANCY
NON-RATED
NON-RATED INTERIOR PARTITION WALL
XXX-XXXX-XX-XXXXX DOOR TAG
' 6
G ra p h ic S ca le
/2
1'
-0
G ra p h ic S ca le
/3 2"
'-0
' G ra p h ic S ca le
/1 6"
'-0
' G ra p h ic
S ca le
/8
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
/8
1'
-0
' G ra p h ic
S ca le
/2
1' -0
G ra p h ic S ca le
/4
1'
-0
G ra p h ic S ca le
'-0
Romanyk Consulting Focusing on what matters
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
F
U.S. Department of Veterans Affairs
E
D
C
B
A
F
E
D
C
B
A
910 7 6 5 4 3 2 1
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
8910 7 6 5 4 3 2 1 of Romanyk Consulting Corp. www.romanykconsulting.com 3308 Preston Road, Suite 350-164, Plano, Texas 75093
NOT FOR
PERMITTING OR
CONSTRUCTION
A/E:Consultant:
VISN 7 LIFE SAFETY SURVEY AND
DRAWING UPDATE, TASK ORDER
#13
GS-10F-0347P
Elijah Knight, PE
R R o m a n y k C o n s u lt in g \R
C C
A E
C
C o n s u lt in g \0
P ro je c ts
\V
IS
N
\L if e
S a fe ty \0
M o d e l\
A tl a n ta \B u ild in g s S u rv e y e d
\A T
-1
F o rt M c P h e rs o n
H o m e le s s P ro g ra m \A
T -1
F o rt
M c P h e rs o n H o m e le s s P ro g ra m
.r v t
/1
/2
:0
:0
A
M
FIRE/SMOKE DOOR INSPECTION FLOOR PLAN -
LEVEL 02
E.K. HP
LS0402
VISN 7 ATLANTA
07/31/2018
VISN 7
ATLANTA
100% SUBMITTAL
NORTH ARROW
FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 02
1/8" = 1'-0"
Note Number Fire Door Note
1 VISIBLE SIGN OF DAMAGE
2 PARTS MISSING OR BROKEN
3 SURFACE HOLES IN DOOR OR FRAME
4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE
4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE
5 FAILED GLAZING AND FRAME INSPECTION
6 SELF-CLOSING DEVICE NOT OPERATIONAL
7 COORDINATOR NOT OPERATIONAL
8 LATCHING HARDWARE NOT OPERATIONAL
9 AUXILIARY HARDWARE INTERFERENCE
10 EDGE CLEARANCE NOT ACCEPTABLE
11 DOOR CLEARANCE NOT ACCEPTABLE
12 SIGNAGE DOES NOT MEET REQUIREMENTS
13 FIELD MODIFICATIONS VOID LABEL
Note Number Fire Smoke Door Note
1 VISIBLE SIGN OF DAMAGE
2 PARTS MISSING OR BROKEN
3 SURFACE HOLES IN DOOR OR FRAME
4a DOOR LABELS CLEARLY NOT VISIBLE AND LEGIBLE
4b FRAME LABELS CLEARLY NOT VISIBLE AND LEGIBLE
5 FAILED METAL DOOR FRAME INSPECTION
6 FAILDED GLAZING AND FRAME INSPECTION
7 SELF-CLOSING DEVICE NOT OPERATIONAL
8 COORDINATOR NOT OPERATIONAL
9 LATCHING HARDWARE NOT OPERATIONAL
10 AUXILIARY HARDWARE INTERFERENCE
11 EDGE CLEARANCE NOT ACCEPTABLE
12 DOOR CLEARANCE NOT ACCEPTABLE
| Sheets |
| G-04 - COVER |
| G-04X1 - GENERAL SHEET |
| G-04X2 - GENERAL SHEET |
| LS0401 - FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 01 |
| LS0402 - FIRE/SMOKE DOOR INSPECTION FLOOR PLAN - LEVEL 02 |
File details come from the government source that posted it. Updated .