18-VAMC-SYR VA Mech Schedules _ Details (M-501R).pdf

PDF 211 KB Posted

Attached to
Z1DA--NRM-CONST 528A7-18-716 RENOVATE MAIN KITCHEN
Solicitation number
36C24223B0017
Issued by

View the file

Other files

File Type Posted
36C24223B0017 0010.docx DOCX document
140-CEILING-2ND FL UNIT A FLOOR PLAN 1-C-13-AUG.pdf PDF
29AUG23_VAMC-RFI REVISIONS - FULL DRAWING SET.pdf PDF
36C24223B0017 0009.docx DOCX document
29AUG23_VAMC-RFI REVISIONS_528A7-18-716_Kitchen_Specifications.pdf PDF
116-HVAC 2ND FL UNIT A FLOOR PLAN 1-H-13-8-16-23.pdf PDF
046-FIRE PROTECTION-2ND FL UNIT A FLOOR PLAN 1-FP-13-8-16-23.pdf PDF
058-ELECTRICAL-LIGHTING and SIGNAL-2ND FL UNIT A FLOOR PLAN 1-E-28-8-16-23.pdf PDF
019-PLUMBING-2ND FL UNIT A FLOOR PLAN 1-P-13-8-16-23.pdf PDF
36C24223B0017 0008.docx DOCX document
15AUG23_VAMC-RFI REVISIONS - FULL DRAWING SET.pdf PDF
024-24 of 190 FRONT -NORTH - and REAR - SOUTH ELEVATIONS_1-24-8-16-23.pdf PDF
15AUG23_VAMC-RFI REVISIONS_528A7-18-716_Kitchen_Specifications.pdf PDF
36C24223B0017 0007.docx DOCX document
36C24223B0017 0006.docx DOCX document
36C24223B0017 0005.docx DOCX document
528A7-18-716 Renovate Main Kitchen Specifications_Revised_V4.pdf PDF
36C24223B0017 0004.docx DOCX document
36C24223B0017 0003.docx DOCX document
046-FIRE PROTECTION-2ND FL UNIT A FLOOR PLAN 1-FP-13.pdf PDF
RFI Q and A- Renovate Main Kitchen- 27 June 23.docx DOCX document
528A7-18-716 Renovate Main Kitchen Drawings_Revised_V4.pdf PDF
024-24 of 190 FRONT (NORTH) _ REAR (SOUTH) ELEVATIONS. 1-24 - Copy.pdf PDF
019-PLUMBING-2ND FL UNIT A FLOOR PLAN 1-P-13.pdf PDF
140-CEILING-2ND FL UNIT A FLOOR PLAN 1-C-13.pdf PDF
36C24223B0017 0002.docx DOCX document
528A7-18-716 Renovate Main Kitchen Drawings_Revised_V2.pdf PDF
36C24223B0017 0001.docx DOCX document
528A7-18-716 Renovate Main Kitchen Plans Revisions by Sheet Number.docx DOCX document
528A7-18-716 Renovate Main Kitchen Specifications_Revised_V2.pdf PDF
528A7-18-716_08M_MECH-ALT_528A7-21-SL01.pdf PDF
528A7-18-716 Renovate Main Kitchen Specifications_Revised_V2 02.pdf PDF
NY20220026.pdf PDF
36C24223B0017_1.docx DOCX document
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOTES:

1.

2.

3.

4.

SIX INCH [150mm] PLENUM AS SHOWN SHALL BE SUPPLIED BY MANUFACTURER OF

FAN COIL UNIT.

SEE DETAIL FOR SUPPLY & RETURN PIPING CONNECTIONS.

PROVIDE ACCESS FOR FILTER REMOVAL.

SEE FAN COIL UNIT SCHEDULE FOR PIPE SIZES.

SUPPLY & RETURN GRILLES SHALL BE SIZED TO SUIT CONNECTIONS ON FAN COIL

UNIT. DUCTWORK SHALL SUIT GRILLES AND FAN COIL UNIT FURNISHED.

6" PLENUM

FINISHED CEILING

4-WAY DEFLECTION

SUPPLY AIR GRILLE

HANGER ROD

SUPPORTS SECURE TO

STRUCTURE ABOVE

WITH SPRING

ISOLATORS (TYP)DUCT SIZE TO SUIT

SUPPLY AIR GRILLE

304 SS DRAIN PAN &

PIPE CONNECTION

FOR SOFFIT SEE

ARCH. DRAWINGS RETURN AIR GRILLEACCESS DOOR SIZED TO

ALLOW ACCESS TO

ELECTRICAL AND COIL

CONNECTIONS AND

ALLOW FOR MOTOR/FAN

ASSEMBLY REMOVAL

COIL

FAN

FILTER

TERMINATE OVERFLOW

DRAIN ABOVE

LAVATORY, SINK, OR

FLOOR DRAIN

INSULATE FULL

LENGTH OF THE

CONDENSATE DRAIN

PIPING

ACCESS DOOR

HEATING ONLY PANELS

HWS

HWR

RUNOUT & INTERCONNECTING PIPING.

PROVIDE DIELECTRIC FITTINGS AS

REQUIRED. CIRCUIT TO COMPLY WITH

SPECIFIED CAPACITY & PRESSURE DROP.

(TYP.)

NOTE:

1. MINIMUM FLOW SHALL BE NO

LESS THAN 0.5 GPM

TEST PLUG

1.

2.

3.

4.

5.

6.

RIGID STRAIGHT TERMINAL UNIT INLET LENGTH SHALL BE A

MINIMUM OF 3 TIMES THE DIAMETER OF INLET

A FLEXIBLE AIR DUCT CONNECTOR IS NOT MANDATORY FOR

INLET TO THIS BOX, BUT ALLOWED TO ACCOMMODATE MINOR

OFFSETS. MAXIMUM LENGTH 3'-0" [900mm].

A BRANCH DUCT SERVING AN INDIVIDUAL BOX MAY BE THE

SAME SIZE AS THE BOX INLET, PROVIDED THE EQUIVALENT

LENGTH OF THE BRANCH DUCT, AS SHOWN, DOES NOT EXCEED

10 FEET (3 METERS). FOR LONGER LENGTHS, INCREASE THE

DUCT SIZE AND PROVIDE A DUCT TRANSITION TO MAINTAIN THE

DUCT STATIC PRESSURE DROP AT OR BELOW 0.2"/100' [1.64Pa/m].

FLEXIBLE AIR DUCT CONNECTORS, WHEN USED FROM TERMINAL

UNIT SUPPLY AIR DUCT TO DIFFUSER, SHALL NOT EXCEED 5'-0"

[1500mm]. USE RIGID ELBOWS FOR CHANGE OF DIRECTION

GREATER THAN 45°.

COMPONENT ARRANGEMENT MAY VARY BY MANUFACTURER.

PROVIDE INSULATION W/VAPOR BARRIER FOR CONNECTING

DUCT SECTIONS.

USE OF THE FLEXIBLE AIR DUCT CONNECTORS ARE NOT

PERMITTED FOR THE DEDICATED AHU SERVING THE SURGICAL

SUITE.

SEE NOTE 3

SEE NOTE 1

SEE NOTE 2

DIFFUSER (TYP)

FLEX DUCT CONNECTOR

SOUND ATTENUATOR

REHEAT COIL

VAV

SE

E

N O

TE

RADIANT CEILING PANEL SCHEDULE (HYDRONIC )

MARK

CIRCUIT

NUMBER

BASIS OF DESIGN

NUMBER

OF

PANELS

PANEL SIZE

HEATING

REMARKS

MANUFACTURER MODEL

HEATING

CAPACITY EWT LWT

HOT

WATER

FLOW RATE

WPD

IN BTUH °F °F GPM FT

HRP-1 40 48 X 24ARMSTRONG AR-M 2616 140 120 0.26 1.696

VANE VANE

NOTE:

1.

2.

THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND.

ALL STANDARD RADIUS ELBOWS CAN BE SUBSTITUTED WITH SHORT RADIUS ELBOWS. ALL SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES SHALL BE CONSTRUCTED, SUPPORTED AND FASTENED

AS RECOMMENDED BY SMACNA.

R SHALL

EQUAL OR

BE

GREATER

THAN W.

R SHALL

EQUAL OR

BE

GREATER

THAN

1/3W.

R SHALL

EQUAL OR

BE

GREATER

THAN

1/6W.

STANDARD RADIUS OR LONG

RADIUS ELBOW

SHORT RADIUS

ELBOW WITH

ONE VANE

SHORT RADIUS

ELBOW WITH

TWO VANES

W

R

R

2/3W 1/ 3W

W W

1/2W 1/ 3W

1/6W

R

NOTE:

1.

2.

3.

4.

ALL VANE ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY SMACNA.

WHEN W1 DOES NOT EQUAL W2, VANE SHALL BE SINGLE THICKNESS VANE TYPE REGARDLESS OF W

DIMENSION.

ALL SINGLE THICKNESS VANES SHALL HAVE A 2" [50mm] RADIUS, 1 1/2" [40mm] MAXIMUM SPACE BETWEEN VANES AND A 3/4" [20mm] TRAILING EDGE.

WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" [500mm] VANES SHALL BE DOUBLE VANE TYPE.

W

W1

NOTE:

UNLESS OTHERWISE INDICATED ON PLANS, MAXIMUM ANGLES SHOWN SHALL APPLY.

MAX.

M

AX.

EQ

U

IP

M

EN

T

AIR FLOW AIR FLOW

TYPICAL DUCTWORK TRANSITION

PLAN OR SIDE VIEWTYPICAL DUCTWORK TRANSITION WITH

EQUIPMENT MOUNTED IN DUCT

PLAN OR SIDE VIEW

MAX.

M

AX.

M

AX

M

AX

30°

15°

15°

5 FT

THRU [20]

6 8 10

[32][25] [40]

[65]

[50]

[75]

-1312 14 -16 -

[125][100]

[150]

[250]

[200]

[300]

[400]

[350]

[450]

[600]

[500]

20 241814 16128 1064 532 2 1/21 1/21 1 1/4

[9100] [9600][8500][7600] [8200][7000][5800] [6700][5200][4100] [4900][3700][3000] [3400][2700][2100]

--- --[4900] -[4100][3700] [4000] -[3000][2400][1800][1500]

THRU 3/4

[2100] [2100]

[2100]

[2700]

[2400]

SIDE VIEW TRAPEZE HANGER FOR UP TO 1000

LB. [453KG] UNIFORM LOAD

ADJUSTABLE CLEVIS HANGERTYPE 1

- SEE SPECIFICATIONS

ADJUSTABLE CLEVIS HANGER TYPE 43

- SEE SPECIFICATIONS

MAXIMUM PIPE/TUBING SUPPORT SPACING

NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE.

NOM. SIZE

PIPE

TUBING

IN.

[mm]

FT.

[mm]

FT.

[mm]

[2 5m m

1" M

AX

PROVIDE INSULATION SHIELD

& INSERT FOR ALL PIPING

(8" [200mm] MIN.)

BAND

1-5/8" [43mm] 12 GAUGE CHANNEL OR 2"x2"x1/4" [50x50x6.4mm] ANGLE

1/2" [15mm] DIA.

HANGER RODS WITH

36" [900mm] MAX.

SPACING ON EACH

CHANNEL

WELD

SADDLE

INSULATION SHIELD

AT HANGER

PROVIDE HIGH COMPRESSIVE

STRENGTH INSULATION (9 PSF

MIN. DENSITY) UNDER

INSULATION SHIELD

INSULATION (VAPOR

BARRIER TYPE IS

REQUIRED FOR LOW

TEMPERATURE PIPE)

HANGER ROD

NOTES:

SEE SPECIFER FOR DETAILED

HANGER REQUIREMENTS

AIR SPLIT DUCT TAKE-OFF PLAN

VIEW

BRANCH DUCT TAKE-OFF PLAN VIEW

SUPPLY REGISTER TAKE-OFF PLAN

VIEW

AIR FLOW

AIR FLOW

AI

R

F

LO

W

SUPPLY REGISTER OR

BRANCH DUCT

TURNING VANES

MAIN

SUPPLY

DUCT

SEE FLOOR PLAN

FOR

SPLIT DIMENSION

PROVIDE VOLUME

DAMPER

PROVIDE VOLUME

DAMPER

ADJUSTABLE

METAL ROD OR

LINKAGE

TOP REGISTER

MAIN

SUPPLY

DUCT

VOLUME EXTRACTOR; ADJUSTABLE FROM

FULLY CLOSED POSITION TO CFM NOTED ON

FLOOR PLANS

AIR FLOW AIR FLOW

1/4 W OR 4"

[100mm]

MIN.

AIR FLOW

MAIN SUPPLY DUCT

AI

R

F

LO

W

W

COIL

TEST PLUG (TYP.)

REDUCER, IF REQUIRED

WATER RETURN

MANUAL AIR VENT

UNION

CONNECTIONS

(TYP.)

WATER SUPPLY

SHUT OFF VALVE

DRAIN WITH HOSE

CONNECTION

MV

MODULATION CONTROL VALVE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD A/E:

STAMPCONSULTANTS

321 4 5 6 7 8 9 10

ARCHITECT:

Watson Engineering, P.C.

1112 State Rte. 434 Owego, NY 13827 (607)223-4334

C&S Companies 499 Col Eileen Collins Blvd Syracuse, New York, 13212

(315) 455-2000

RENOVATE MAIN KITCHEN

SYRACUSE VA MEDICAL CENTER

528A7-18-716

BUILDING 1

09/08/2023 DW JD

KITCHEN CONSULTANT:

Commercial Kitchen Consulting 21 Powers Rd Binghamton, New York, 13903

(607) 242-5571

BI

M

8A 7-

-7

R en ov at e

M ai n Ki tc he n/ R en ov at e

M ai n Ki tc he n_ R

.rv t

/1 7/

:2

9:

P M

M-501R

MECHANICAL SCHEDULES AND

DETAILS

SPACE

INFORMATION

COOLING LOADS

HEAT LOAD

REQUIRED ROOM AIRFLOWS DESIGN AIRLFOWS FOR

FINAL BALANCING

SENSIBLE TOTAL TOT ACH CLG FLOW HTG FLOW SUPPLY (MAX) RETURN

ROOM ID/# BTU/HR BTU/HR BTU/HR QTY CFM CFM CFM CFM

C205D 18,567 30,882 2,896 15 1,352 1,352 1,360 1,360

C205J 9,876 14,555 2,097 15 450 418 450 450

ROOM AIR SCHEDULE

ID LOCATION

TERMINAL UNIT SCHEDULE

BASIS OF

DESIGN TYPE

INLET

SIZE

(IN)

AIRLFOW (CFM)

DESIGN UNIT MAX UNIT MIN

HW HEATING COIL

ENTERING

AIR TEMP

(F)

LEAVING

AIR TEMP

(F)

STATIC

PRESSURE

(IN. WC.)

ENTERING

WATER

TEMP (F)

LEAVING

WATER

TEMP (F)

FLOW

(GPM)

HEAD

(FT)

2-VAV-42S

1-VAV-42S

TITUS DESV

TITUS DESV

B202A

B202

REHEAT

BYPASS

24X16

ROOM

C205J

C205D

COOLING

SETPOINT

(F)

HEATING

SETPOINT

(F)

MIN

RELATIVE

HUMIDITY

MAX

RELATIVE

HUMIDITY

DESIGN CONDITIONS

ID LOCATION

FOUR PIPE FAN COIL UNIT SCHEDULE

BASIS OF

DESIGN

COOLING COIL

MIN. SENS.

(BTUH)

MIN TOTAL

(BTUH)

ENTERING

AIR (F)

HEATING COIL

GPM

MAX.

COIL

P.D.

1-FCU-42S CARRIER 42DH C205D

FAN

CFM

1,360

DB WB

87 71

MIN.

LOAD

(BTUH)

ENTERING

AIR (F) GPM

MAX.

COIL

P.D.

FAN MOTOR

NOM.

HP

VOLT/

PH/HZ

18,567 30,882 13.8 11400 1.14 1 208/1/60

0.5

1/2" = 1'-0"3 FAN COIL UNIT DETAIL

3/4" = 1'-0"1

HYDRONIC RADIANT CEILING PANELS - PIPING

CONNECTIONS

1/2" = 1'-0"2 DUCT CONNECTION - VAV

PIPE

SIZE

(IN)

PIPE

SIZE

(IN)

DIFFUSER SCHEDULE

TAG MANUFACTURER MODEL DESCRIPTION QTY

ED-1 TITUS PAR 24X24 PERFORATED STEEL EXHAUST DIFFUSER 6

ED-2 TITUS PAR 12X12 PERFORATED STEEL EXHAUST DIFFUSER 4

SD-1 TITUS OMNI 24X24 STEEL PLAQUE FACE SUPPLY DIFFUSER 33

NTS4 DUCTWORK RADIUS ELBOWS

NTS5 DUCTWORK SQUARE VANE ELBOWS

NTS6 DUCTWORK TRANSITIONS

NTS7 PIPE HANGERS

NTS8 SUPPLY DUCTWORK TAKE-OFFS

NTS9

TERMINAL UNIT WATER COILS - PIPING

CONNECTIONS

Sheets and Views
18-VAMC-SYR VA Mech Schedules & Details (M-501R)-Layout1

File details come from the government source that posted it. Updated .