Appendix A1 - TEMPORARY SHELTER RELOCATION.pdf
PDF 566 KB Posted
- Attached to
- Y1JZ--NCOTA 3B Completion Project
- Solicitation number
- 36C10F25B0002
About this file
This document is a technical engineering drawing for a temporary shelter relocation project at the National Cemetery of the Alleghenies in Washington County, Pennsylvania. The drawing, prepared by Gordon Engineering, details specific construction specifications for shelter anchoring and bollard installation, including a site plan with a 1" = 30' scale. The technical details include a 4" diameter steel pipe filled with concrete for shelter anchoring, a 7"x7" column base plate with anchor bolt holes, and a reinforced concrete footing following the original structural drawings. The plan is marked as Revision 1, dated 8-27-20, with a project number of 925PC2006, and affects the original plan CS107 from 5-25-18. The drawing provides precise installation instructions for the contractor, including a requirement to mark proposed post and overhang locations in the field for approval prior to foundation construction.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Gordon
148 S. Queen Street, Suite 201
Martinsburg, WV 25401
Phone: 304-725-8456 www.gordon.us.com
PROGRAMMING AND PLANNING
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE
SURVEY AND MAPPING
SECURITY CONSULTING
SI015 - TEMP. SHELTER RELOCATION
NATIONAL CEMETERY OF THE ALLEGHENIES
PHASE III DEVELOPMENT
PACKAGE "A"
WASHINGTON COUNTY, PA OF
SHEET:
DATE: 8-27-20 REV1
1 1
SCALE: 1" = 30'
PROJECT NUMBER: 925PC2006
ORIGINAL PLAN AFFECTED: CS107
ORIGINAL PLAN SEAL DATE: 5-25-18
SCALE: NTS
SHELTER ANCHORING
1'
2'
3'
3'
FINISHED
GRADE
4" DIA. STEEL PIPE
FILLED WITH
CONCRETE OR
APPROVED EQUAL.
CONTRACTOR TO
PROVIDE
SUBMITTAL/SHOP
DRAWING.
CONCRETE FOOTING
SCALE: NTS
BOLLARD
AutoCAD SHX Text
MAINTENANCE GARAGE
AutoCAD SHX Text
ADMINISTRATION/ MAINTENANCE OFFICE
AutoCAD SHX Text
15" CPP
AutoCAD SHX Text
15" CPP
AutoCAD SHX Text
8" PVC
AutoCAD SHX Text
15" CPP
AutoCAD SHX Text E
AutoCAD SHX Text
15" CPP
AutoCAD SHX Text
15" CPP
AutoCAD SHX Text
15" CPP
AutoCAD SHX Text
CONCRETE WALKWAY
AutoCAD SHX Text
BOLLARD (TYP.)
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
4" SANITARY INFLUENT LINE
AutoCAD SHX Text
4" DIP WATER MAIN
AutoCAD SHX Text
CO
AutoCAD SHX Text RELOCATED TEMPORARY SHELTER. CONTRACTOR TO MARK PROPOSED POST AND OVERHANG LOCATIONS IN FIELD FOR RE APPROVAL PRIOR TO FOUNDATION CONSTRUCTION.
AutoCAD SHX Text
BOLLARD (TYP.)
AutoCAD SHX Text
TEMPORARY COMMITTAL SERVICE SHELTER ANCHORING
AutoCAD SHX Text
HEX NUT, WASHER & ANCHOR BOLT
AutoCAD SHX Text
7"X7" COLUMN
AutoCAD SHX Text
BASE PLATE
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
FINISH GRADE SLAB
AutoCAD SHX Text
REINFORCED CONC. FOOTING AS REQUIRED PER ORIGINAL STRUCTURAL DRAWINGS
AutoCAD SHX Text 8"
AutoCAD SHX Text
MIN.
AutoCAD SHX Text 2"
AutoCAD SHX Text
7"X7" COLUMN
AutoCAD SHX Text
BASE PLATE
AutoCAD SHX Text
A-BOLT HOLE
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
2'-0" SQ. OR ROUND
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 30'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text
BOLLARD SEE DETAIL 2
| Sheets and Views |
| 11x17 |
File details come from the government source that posted it. Updated .