Line # Description Qty
CX50 Radiology Package 11 Interface:
• 15.0 inch high resolution display with wide viewing angle
• Quick Keys and Active Mode
• Laptop style Alphanumeric QWERTY keyboard
• 8 TGCs and 2 LGCs
• Ergonomic carrying handle
• Includes AC adapter, power cord and system battery pack
• 500 GB hard drive
• Internal DVD RW drive Architecture:
All-digital compact broadband beamformer, Microfine 2D focusing with Dynamic Focal Tuning that includes Advanced XRES signal processing, 170 dB full time input dynamic range 504,576 digitally processed channels, Windows Embedded Standard 7 Operating System, Continuously variable steering in 2D, color and Doppler modes 2D Opt signal processing with 4X multi-line parallel processing and frequency compounding. Windows Embedded Standard 7 Operating System.
Intelligent Controls:
The CX50 has been designed to make portable exams easy and efficient. With a single button, iSCAN technology automatically samples data for a new level of 2D and Doppler optimization iSCAN one-touch Intelligent Optimization, iSCAN one-touch Intelligent Color Optimization, iSCAN Doppler one-touch optimization.
Smart Exam: provides easy to use, customizable guides that help the clinician complete studies on every patient. An on screen menu, guides the clinician through the required views for a specific exam type, automatically enters annotation and build the patient report.
Needle Visualization: When used in conjunction with the L12-3 or L12-5 50 linear transducers, Needle Visualization utilizes advanced electronic beam-steering technology to enhance viewing of the needle to assist the user in guiding the needle to the target anatomy.
Transducers:
The CX50 General Imaging system supports the compact family of transducers including S5-1, S12-4, S8-3, X7-2t, S7-3t, L12-5 50, L12-3, L15-7io, L10-4lap, C5-1, C10-3v, C8-5,C9-3io, D2cwc and D5cwc (Clinical Option/Clinical Package dependent).
All transducers provide breakthrough frequency bandwidths and array configurations. These transducers also have ergonomically designed lightweight flexible cables and compact connectors.
Modes:
• 2D
• M-mode
• Anatomical M-mode
• Color M-mode
• Pulsed Wave Doppler
SHIP TO:
RMR VAMC B90022
V.A. Medical Center
RECEIVING DOCK
1700 N. WHEELING ST
AURORA, CO 80045
REQUESTING SERVICE: IMAGING(114)
P.O.# 554-B90022
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
Sticky Note Unmarked set by AMMHINWARDM
Line # Part # Description Qty
• Color Power Angio (CPA)
• Continuous Wave Doppler
• Invert and Color Invert
• Color compare mode
• Dual mode
• Duplex for simultaneous 2D and Doppler
• 2D Optimization Signal Processing
• Live Compare
• Tissue Harmonic Imaging (THI)
• Reconstructed zoom with pan (read zoom)
• Write zoom
• Pulse Inversion Harmonic imaging
• Adaptive Doppler
• Adaptive Color Doppler
• Color Tissue Doppler imaging
• Pulsed Wave Tissue Doppler imaging
• Active Native Data - manipulation of image data DICOM Networking
• Ethernet @100Mb/second Includes DICOM wired and wireless g and n .
• Provides DICOM 3.0 network print and store and storage commitment
• Performed Procedure Step
• Modality Worklist
• DICOM Structured Reporting Cineloop review On-board workstation-class data management with thumbnail previews and storage of images, loops, and reports. Retrospective and prospective clip capture to internal drive or removable media Integrated DVD/CD burning capability for storage of images or export in DICOM, JPEG and .avi for PC compatibility. Philips DICOM viewer option to imbed in media transfer for easy viewing of study on most PCs.
Maintenance and Serviceability
• Remote Access for Expedient Clinical and Technical Support
• Flexible Service Agreements
• Clinical Application and Educational Support
• Scheduled Preventative Maintenance and System Optimization Security-related features
• Firewall policy blocks all unnecessary ports
• Operating System hardening
• OS settings utilizing the DISA STIGS
• Disable unnecessary services
• Disable auto-run for removable media System Access Control
• No restrictions – users may perform exams and access all previously completed exams or MWL data
• Only patient data is locked – users may perform exams without requiring a login, but must successfully log in prior to accessing previously completed exams or Modality Worklist data.
• Complete system is lockable – users and administrators must successfully log in prior to any system access
Local User Management
• Support for multiple unique user accounts
• Support for multiple unique administrator accounts Remote User Management
• Supports active directory authentication utilizing LDAP (system may not be joined to the domain)
• Support for individual accounts or AD groups for users and administrators
• May utilize LDAP or secure LDAP
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
Auto logoff
• Automatically logs off a user after the specified period of inactivity, user selectable
Hard drive encryption
• System supports various hard drive encryption policies including:128 bit, 128 bit with diffuser, 256 bit, 256 bit with diffuser
Audit log export
• Available protocols are UDP or TLS Media export security
• Provides the ability to disable export of patient data to removable media
Safeguard This is a standard computer administration tool used to prevent unauthorized programs (malware) from running on the ultrasound system.
Cart w/ Multi-port Adapter Highly mobile cart that features hardware module to support transducer switching among up to three imaging transducers at the touch of a button. Includes: 4 swivel wheels with 2 locking casters, rear handle, micro-positioning grips, quick-connect tray, storage shelf, footrest, internal isolation transformer, B&W printer brackets, integrated transducer connector holder, gel holders and cable management. Includes USB hub for additional connectivity.
AC Adapter A stand-alone combination switching power supply with medical isolation and intelligent battery charger used to power the CX50 from world-wide AC power mains while charging the system’s Lithium Polymer battery. Power adapter allows system to run on AC power.
Battery Pack A multi-cell Lithium polymer smart battery pack that is internal to the CX50. Complies with UL1642, Standard for Safety for Lithium Batteries. 6.4 Amp-Hours minimum (16.8V to 10.8V) 5.17” X 5.360” X 1.14”, 840 g.
Radiology Clinical Package w/ Peds
This clinical option package includes the Abdominal, Vascular, OB/GYN, Musculoskeletal, Small Parts, and Pediatric Radiology clinical options.
Abdominal Clinical Option This clinical option includes abdominal Tissue Specific Imaging software, SonoCT and Freehand 3D for abdominal applications. This clinical option also includes analysis and reporting packages for abdominal applications. Allows operation for abdominal applications of the C5-1, S5-1 and L12- 3 transducers.
Vascular Clinical Option This clinical option includes Tissue Specific Imaging software and SonoCT for Cerebrovascular, Peripheral vascular, abdominal vascular and Transcranial applications. This clinical option also includes in-depth analysis and reporting packages for vascular applications. Freehand 3D is also provided within this clinical option. Allows operation for vascular applications of the C5-1, S5-1, L12-3 and D5cwc transducers.
OB/GYN Clinical Option This clinical option includes OB/GYN Tissue Specific Imaging software, SonoCT and Freehand 3D for OB/GYN applications. This clinical option also includes in depth analysis and reporting
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
Sticky Note Unmarked set by AMMHINWARDM
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
Sticky Note Unmarked set by AMMHINWARDM
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
packages for OB/GYN applications. Allows operation for OB/GYN applications of the C5-1 and C10-3v transducers.
Musculoskeletal Clinical Option This clinical option includes MSK Tissue Specific Imaging software, SonoCT and Freehand 3D for MSK applications. This clinical option also includes analysis and reporting packages for MSK applications. Allows operation for MSK applications of the L12-3.
Small Parts Clinical Option This clinical option includes small parts Tissue Specific Imaging software, SonoCT and Freehand 3D for a wide range of small parts applications (eg. Breast, thyroid, testicle) . This clinical option also includes analysis and reporting packages for small parts applications. Allows operation for small parts applications of the L12-3 and C5-1.
Pediatric Radiology Clinical Option Tissue Specific Imaging software for appropriate curved array and sector array transducers in pediatric ultrasound applications. Display optimization software with Tissue Specific presets for 2D imaging and Doppler applications. Analysis software package includes a general imaging protocol and report. Allows operation of S12-4, S8-3, and C8-5 transducers.
Clinical Education
Implementation Onsite Training - One day of basic system training is provided at your site after installation. Ultrasound system or upgrade onsite training provided by a PAS (Product Applications Specialist) for specific system applications or upgrades; not per modality.
Education is provided Monday - Friday during normal business hours.
Note: Philips Healthcare personnel are not responsible for actual patient contact or operation of equipment during education sessions except to demonstrate proper equipment operation. The training sessions should be attended by the appropriate healthcare professional as identified by the department director. Repeat training for staff non-attendance will not be accepted. Site must be patient-ready to meet training expectations. All onsite training day expires within 90 days from system or upgrade installation date. Exceptions are for 3D Stress onsite training (which expires 9 months from system or upgrade installation date) and Fusion & Needle Navigation onsite training (which expires 180 days from system or upgrade installation date).
USA Power Cord 12
C5-1/ L12-3 Transducer Bundle 13 This GI Transducer Bundle includes the C5-1 and L12-3 for use on the CX50 ultrasound system.
The available imaging presets are determined by the clinical options purchased with the system.
L15-7io Transducer 14 Features compact connector designed for reliability and improved ergonomics. Manufactured in accordance with the European Union’s Restriction of Hazardous Substances (RoHS) directive.
High frequency compact linear array transducer with 15 to 7 MHz extended operating frequency range for cardiac and vascular surgery, superficial vascular, and MSK applications. (Compact connector)
English Manual 15 Operation Manual
OPTIONS
Line # Description Qty
CX50 Integrated US Client - Allura Xper FD Connect
CX50 IUS Client SW streamlines workflow by offering synchronization of Patient ID information already entered into the Allura Xper system, as well as storage of ultrasound images within the Interventional Study folder.
Enables tableside control of ultrasound exams via the Allura Xper Tableside Module (TSM)
Seamless connection with Allura video system supports comfortable viewing of images on interventional exam room monitors
Operational Requirements:
CX50 Release 2 (or later) software release level.
Philips Allura Xper Release 7 (or later) in Interventional Suite.
Allura Xper Integrated Ultrasound option purchased separately. (IUS functionality requires both “client” and “host” software - CX50 IUS option is “client” software).
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
Sticky Note Unmarked set by AMMHINWARDM
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
Sticky Note Unmarked set by AMMHINWARDM
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
File details come from the government source that posted it.