Item QTY Description
1 1 DRX Revolution
1 DRX-Revolution Mobile X-Ray System
Carestream's innovative mobile X-ray room on wheels. The DRX- Revolution offers bins for gloves, paperwork, markers, bags and a lockable storage space for the detector. The collapsible column allows increased visibility and safety when driving the system.
The tube arm can reach over 53 in (135 cm) to accommodate larger beds and crowded rooms while the system has 32 kW of power for shorter exposure times and more flexible technique selection. Dual, independent drive motors provide easy maneuverability and a maximum drive speed up to 3.5 m/h (5.6 km/h). An integrated proximity badge reader automatically logs the operator into the software and displays the patient worklist. Two touch-screen displays provide dual work zones with a 19 in.
main monitor and 8 in. tube head monitor that allow the user to:
• display the patient worklist
• review prior images (optional software)
• copy or change technique
• accept or reject imagesOther features include:
• Integrated 1D barcode reader
• 2 integrated battery chargers for detector batteries
Birmingham VA Medical Center - Digital Portable Birmingham VA Medical Center
TRADE-IN:
GE
AMX-4
EE# 34278
SERIAL NUMBER: S1740026-180)
REQUESTING SERVICE: RADIOLOGY SERVICE
SHIP TO: CHIEF, A&MM
V.A. Medical Center
700 SOUTH 19TH ST
BIRMINGHAM, AL 35233
REQUISITION: 521-B92005
• Integrated storage bins for 1 DRX-1 detector, 1 2530C detector, 1 portable grid holder or grid alignment device
• Wired exposure switch
• Direct access to RIS/
PACs
X-Ray Generator:
• Maximum Power Output
32kW
• Vp Range 40 to 150 kVp
• mAs Range 0.1 to 320 mAsX-RAY Tube:
• Focal Spot Size: 0.6 mm / 1.2 mm
• Target Angle: 14 degrees
• Anode Heat Capacity:
300 kHU (212 kJ)Tube Head Movement:
• Maximum SID to Floor:
2022 mm (79.6 in.)
• Minimum SID to Floor:
683 mm (26.9 in.)
• Tube Arm Reach: 1351 mm (53.2 in.)
• Column Rotation Range:
+/- 270 degrees
• Tube Rotation: +180 degrees CW/-135 degrees CCW
• Tube Tilt: -10 to +90 degrees
• Collimator Rotation Range: +/- 90 degreesPhysical Characteristics:
• Weight: 575 kg (1268 lbs)
• Height (column collapsed): 1295 mm (51.0 in.)
• Height (column extended): 1956 mm (77.0 in.)
• Width: 576 mm (22.7 in.)
• Length: 1219 mm (48.0 in.)
Birmingham VA Medical Center - Digital Portable
Birmingham VA Medical Center
1 DRX Plus 3543 Detector
Wireless, cassette-size, 35 x 43 cm GOS Detector for fast workflow and instant access to images. Fits into standard Bucky trays and the wireless capability make it also ideal for tabletop use.
• Wireless standard:
802.11n
• Image size: 35.0 x 42.3 cm
• Pixel Pitch: 0.139 mm
• External Dimensions: 35 x 43 Cassette (ISO 4090) 38.35 x 45.95 x
1.47 cm
1 EVP Plus Imaging Processing Software
Provides highly automated, state-of-the-art image processing. Uses multi-frequency image processing to increase latitude while preserving detail contrast in both over-penetrated and under-penetrated areas. Automatically processes and delivers diagnostic quality images to PACS based on look preference that can be uniquely specified by each site.
Includes grid line suppression that prevents aliasing artifacts and application of a collimator mask. Five independent controls are available for the user for image adjustments in an intuitive user interface.
1 Modality Worklist Software
Facilitates automatic transfer of patient and procedure data from your HIS/RIS system, eliminating manual data entry, and increasing technologist productivity.
1 Administrative Analysis and Reporting Software
Provides consolidated user-friendly reports from all Carestream CR and DR systems on the network. Example reports include repeat statistics by user and exam type, exposure data by user and exam, detector usage, system use by radiographer and much more. Users can also generate custom reports. Helpful for performance tracking and operational improvements.
1 CARESTREAM Remote Management Services
State-of-the-art technology that allows Carestream Health to proactively monitor, diagnose and fix malfunctioning equipment even before it stops working.
Provided to all warranty and contract customers, and available for current PACS, IMS, RIS, CR and DR product lines.
1 Two Handle Port Grid and Holder 103 Lpi 6:1 40-72 Fd 130 Cm
1 2D Barcode Reader for DRX
2D Barcode Reader for DRX
1 Prior Image Review
Retrieve and review images from PACS to review anatomy and positioning and copy techniques to the current exam in order to standardize exposure techniques for optimal image quality.
1 ICU Software Package
Package includes:
Tube and Line Visualization
Creates a companion image from the original exposure with optimized processing for clearer, easier visualization of PICC lines and tubes. With a single exposure, the software It increases confidence that tubes and lines are placed correctly.
Pneumothorax Visualization
Creates a companion image from the original exposure that is optimized to accentuate the appearance of free air in the chest cavity.
Auto-Correct for Image Display
Analyzes the image content and presents chest images in the proper orientation regardless of detector orientation
2 DRX Detector Battery
1 Standard side panels for DRX- Revolution
2 12 Proximity Badges
1 Fips Option for DRX- Revolution
1 STANDARD COLLIMATOR FOR
DRX-REVOLUTION
1 DRX Detector Battery
DRX Detector Battery
1 SmartGrid Software
SmartGrid feature is a software option that provides, upon request by user, a diagnostic radiograph image with a reduction in visible x-ray scatter similar to the effect of an anti-scatter grid.
1 Cord Reel (USandC)
2 1 Professional Services
1 Applications DRX REVOLUTION Key Operator Training - 2 days
To provide the Operator with the skills necessary to use the Revolution system and produce images for diagnostic interpretation. It also provides an overview of Key Operator functions to allow the Key Operator to define system requirements and procedures necessary to configure the system according to the site's workflow environment. The Key Operator training is provided using the train-the-trainer philosophy, thus Key Operators can continue training your current staff as well as new staff in the future.