36A79719Q0008-009.pdf

PDF 91 KB Posted

Attached to
February 2019 Consolidation
Solicitation number
36A79719Q0008
Issued by

About this file

36A79719Q0008 541-B63032 - WORKSTATION, VAMC CLEVELAND, OH redacted.pdf

View the file

Other files

File Type Posted
36A79719Q0008-0003000.docx DOCX document
36A79719Q0008-0002000.docx DOCX document
36A79719Q0008-0001002.xlsx XLSX spreadsheet
36A79719Q0008-0001000.docx DOCX document
36A79719Q0008-058.pdf PDF
36A79719Q0008-041.zip ZIP file
36A79719Q0008-021.pdf PDF
36A79719Q0008-068.xlsx XLSX spreadsheet
36A79719Q0008-042.zip ZIP file
36A79719Q0008-038.pdf PDF
36A79719Q0008-031.pdf PDF
36A79719Q0008-020.pdf PDF
36A79719Q0008-052.pdf PDF
36A79719Q0008-025.pdf PDF
36A79719Q0008-026.pdf PDF
36A79719Q0008-005.pdf PDF
36A79719Q0008-010.pdf PDF
36A79719Q0008-044.pdf PDF
36A79719Q0008-007.xlsx XLSX spreadsheet
36A79719Q0008-011.pdf PDF
36A79719Q0008-071.pdf PDF
36A79719Q0008-040.pdf PDF
36A79719Q0008-054.pdf PDF
36A79719Q0008-055.pdf PDF
36A79719Q0008-022.pdf PDF
36A79719Q0008-004.docx DOCX document
36A79719Q0008-061.pdf PDF
36A79719Q0008-057.pdf PDF
36A79719Q0008-056.pdf PDF
36A79719Q0008-063.pdf PDF
36A79719Q0008-017.pdf PDF
36A79719Q0008-039.pdf PDF
36A79719Q0008-032.pdf PDF
36A79719Q0008-048.pdf PDF
36A79719Q0008-035.pdf PDF
36A79719Q0008-049.pdf PDF
36A79719Q0008-015.pdf PDF
36A79719Q0008-014.pdf PDF
36A79719Q0008-037.pdf PDF
36A79719Q0008-070.pdf PDF
36A79719Q0008-030.pdf PDF
36A79719Q0008-036.pdf PDF
36A79719Q0008-051.pdf PDF
36A79719Q0008-053.pdf PDF
36A79719Q0008-046.pdf PDF
36A79719Q0008-034.pdf PDF
36A79719Q0008-008.pdf PDF
36A79719Q0008-019.pdf PDF
36A79719Q0008-065.pdf PDF
36A79719Q0008-003.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Unit Net

Qty Description

1 RadPRO® DELINIA® 200 Digital X-ray Acquisition Cart with Dual Canon CXDI-710C Wireless Detectors, Single CXDI-810C Wireless Detector and Auto Detection RadPRO® DELINIA® 200 Digital X-Ray Acquisition Cart with Canon CXDI-710C Wireless Detector and Auto Detection

Acquisition Cart

Canon CXDI-710C Wireless Digital Radiography System is an advanced wireless digital radiographic device for a broad range of radiographic applications, including trauma, ICU and bedside imaging. The shape of the detector, which is identical to that of a conventional film cassette complying with ISO4090, enables digital radiography in the existing analog radiography configuration. The sensor with 125µm pixel pitch and CsI (Cesium Iodide) used for the scintillator produces high-resolution (approx. 9.5 MP) digital images within the effective imaging area (350 x 426 mm).

The Canon CXDI-710C Wireless Digital Detector is lightweight, using new CFRP construction, weighing approximately 5.07 lbs (2.3kg) including battery pack and measures 14 in. x 17 in.

In X-Ray Auto Detection mode, the CXDI-710C Wireless DR System can detect X-Rays at exposure and acquire images automatically, without the use of a typical generator interface.

It features even further weight reduction over previous detectors in the Canon CXDI series and delivers greater operability than similar existing products as a result of improved water resistance (equivalent to IPX7) and the addition of new features (Standalone Mode and a READY switch). The CXDI-710C Wireless Digital Detector includes built in shock detection function which detects the shock applied to the detector unit and also the free fall of the detector unit. The data saved in the detector is transferred to the PC, can be output to .csv file and used for analysis.

DEL. TO: RADIOLOGY P 10:

WADE PARK WHSE B63032

V.A. Medical Center

CHIEF, ACQ & MAT'L MGT

10701 EAST BOULEVARD

CLEVELAND, OH 44106

P.0.# 541-B63032

Includes:

2 - Battery Packs

Control Station for Canon Control Software NE:

Intel 4th Gen i7 3.8 Ghz cpu Industrial/Long Life Motherboard 8 GB Memory 240 GB SSD Hard drive

802.11 A,B,G,N Dual Band WiFi Radio

Custom Computer Chassis for Delina200 Windows 7 64 Bit Professional (License only) RadPRO Rapid Recover System Keyboard Mouse

22" Touchscreen LCD Monitor

Canon Control Software NE:

System Startup & Quality Assurance

- Standard Mode: No log-in required

- Secure Mode: Operator log-in/password required (user authentication); auto time-out with log-in to last screen viewed

- Warm-up time: None

- Battery/Wi-Fi Monitor: Software to allow wi-fi strength monitor and battery monitor for CXDI-70C Wireless configurations.

- Calibration Routine: Included; required once per year; configurable on-screen reminder message

- Display QA: SMPTE pattern included

Image Acquisition

- Programming: Unlimited anatomically programmed acquisition settings; user customizable to include annotation, orientation, patient demographics display location, and pre-selected basic and enhancement processing

- Reject/Retake: Reject, Retake, Un-Reject; Reject reason labeling with free or pre-set annotation; Reject log (.csv monthly file accessible to system administrator for rolling 12 months)

- Grid Suppression: Software-based grid suppression

- Protocol Pre-Pack: Allows for multiple APR views to be associated into one APR for easy grouping of views within a study.

- Auto-Stitch (v1.2): Multiple images can be stitched together within the software.

Image Processing

- Basic Processing: Histogram analysis by automatic fixed region ROI or user adjustable ROI; grayscale conversion; adjustable brightness and contrast; 6 pre-set contrast enhancement curves; collimation edge detection and (black) masking with adjustable standoff; trim positioning and adjustment

- MTF Improvement: Preset and user-selectable/adjustable anatomical region-based filters, intensity levels

- Standard Processing: Preset and user-selectable/adjustable DEP (dynamic range adjustment), edge enhancement, noise reduction

- Preset and adjustable multi-frequency dynamic range adjustment; global edge enhancement

- Preset and user-selectable/adjustable dynamic range adjustment; noise reduction, local edge enhancement

- Security advancements allow for only select users to access full image processing protocols.

Data Output and Network Connection

- DICOM Print Format: Multi-format, user selectable pre-exposure and post-exposure formatting; selectable printing method (fixed ratio, life size, reduction, fit to film);

queue viewable with priority and cancel capabilities; up to 2 DICOM printers may be specified at any one time, up to 4 DICOM printers may be configured

- Study transmission: Selectable modes - after each image, after study end, post-study retrieval with resend individual or all image capabilities; queue viewable with priority and cancel capabilities; up to 2 storage devices may be specified at any one time, up to 4 storage devices may be configured

- CD Archive: Available as network selectable storage device with DICOMDIR (hardware not included)

- Network: Ethernet 10/100/1000 Base T, RJ45 standard

- Data Output: DX; DICOM 3.0 compliant, Print Management Service Class (SCU), Storage Service Class (SCU) and others

- IHE Profiles: Basic Security Profile option - User Authentication, Audit Log, Time Synchronization, Node Authentication

DICOM Modality Worklist for Canon CXDI Digital Radiography systems is a communications module for acquiring patient information and exam requirements from the HIS / RIS. The following features are available in this module:

Study Information Acquisition

- Study is configurable to include a wide variety of patient information such as name, sex, birth date, age, patient ID, accession number(s), referring physician, etc.

- Find Mode is available and conforms to Modality Worklist SOP Class (MWL).

- Patient information can be entered manually if the patient does not appear on the

AMMHINWARDM

Sticky Note None set by AMMHINWARDM

AMMHINWARDM

Sticky Note MigrationNone set by AMMHINWARDM

AMMHINWARDM

Sticky Note Unmarked set by AMMHINWARDM worklist.

- When used with a portable imaging unit, the worklist can be downloaded and stored in the control computer eliminating the need for network access at the patient's bedside. A barcode reader (not included) can be used to find and select the patient from the worklist.

Study Status Notification

- Supports Modality Performed Procedure Step SOP Class (PPS) with in progress, completed, or discontinued messages.

- PPS is available for both suite and portable imaging

- Multi-accession imaging

Imaging Modes

- Manual imaging mode allows the user to individually select each view to be acquired

- Program imaging mode uses the study information sent by the HIS / RIS to pre-configure the exam(s) to be performed

- Images can be acquired in any order

- Additional views can added at any point in the exam

- The study can be ended without completing all views

- 100 views can be acquired for a single patient

- Exams and views can be customized to meet the needs of the facility

* Requires Program Imaging Mode Set Up and Implementation Fee

Optional DICOM tags can be defined, displayed, printed, and transmitted to PACS.

Pregnancy Status can be received from HIS / RIS and an alert displayed to inform the user of the pregnancy status.

Storage Commit function is available.

ID Card Log In Feature Includes: ID Card Reader, 20 ID Cards

Canon Ready Indicator

Canon Battery Charging Unit

Barcode Scanner

Please note that due to HAZMAT shipping requirements Delinia units will ship FedEx LTL Truck Priority or LTL Economy.

Table Grid for CXDI-701C/710C Series and 501 Series Detector Aluminum Interspaced Grid, 132 lpi, 10:1, 34"-44" Focus17 1/4 x 18 7/8"

Wallstand Grid for CXDI-701C/710C Series and 501 Series Detector Aluminum Interspaced Grid, 132 lpi, 10:1, 40"-72" Focus17 1/4 x 18 7/8"

Includes Standard Installation

Includes standard installation, M-F 8am-5pm.

Warranty - One (1) Year Parts and Labor on Acquisition Cart and Canon Products.

- Two (2) years Protection Plus is included with CXDI-710C Wireless, CXDI-810C Wireless and CXDI-410C Wireless Digital Detectors

- Excludes all damage from misuse, abuse, tampering or acts of God

SubTotal

1 Canon CXDI-710C Wireless Digital Detector

Canon CXDI-710C Wireless Digital Radiography System is an advanced wireless digital radiographic device for a broad range of radiographic applications, including trauma, ICU and bedside imaging. The shape of the detector, which is identical to that of a conventional film cassette complying with ISO4090, enables digital radiography in the existing analog radiography configuration. The sensor with 125µm pixel pitch and CsI (Cesium Iodide) used for the scintillator produces high-resolution (approx. 9.5 MP) digital images within the effective imaging area (350 x 426 mm).

The Canon CXDI-710C Wireless Digital Detector is lightweight, using new CFRP construction, weighing approximately 5.07 lbs (2.3kg) including battery pack and measures 14 in. x 17 in.

In X-Ray Auto Detection mode, the CXDI-710C Wireless DR System can detect X-Rays at exposure and acquire images automatically, without the use of a typical generator interface.

It features even further weight reduction over previous detectors in the Canon CXDI series and delivers greater operability than similar existing products as a result of improved water resistance (equivalent to IPX7) and the addition of new features (Standalone Mode and a READY switch). The CXDI-710C Wireless Digital Detector includes built in shock detection function which detects the shock applied to the detector unit and also the free fall of the detector unit. The data saved in the detector

AMMHINWARDM

Sticky Note None set by AMMHINWARDM

AMMHINWARDM

Sticky Note MigrationNone set by AMMHINWARDM

AMMHINWARDM

is transferred to the PC, can be output to .csv file and used for analysis.

Includes:

2 - Battery Packs

1 Canon CXDI-810C Wireless Digital Detector

Canon CXDI-810C Wireless Digital Radiography System is designed for use in a variety of diagnostic imaging areas and radiology rooms. This system is an ideal size for fitting into most wall stands, buckys, mobiles and incubators without modification.

The Canon CXDI-810C Wireless Digital Detector is lightweight, using new CFRP construction, weighing approximately 3.97 lbs (1.8kg) including battery pack and measures 11 in. x 14 in. The sensor with 125µm pixel pitch and CsI (Cesium Iodide) used for the scintillator produces high-resolution (approx. 6.1 MP) digital images within the effective imaging area (351 x 275 mm).

In X-Ray Auto Detection mode, the CXDI-810C Wireless DR System can detect X-Rays at exposure and acquire images automatically, without the use of a typical generator interface.

It features even further weight reduction over previous detectors in the Canon CXDI series and delivers greater operability than similar existing products as a result of improved water resistance (equivalent to IPX7) and the addition of new features (Standalone Mode and a READY switch). The CXDI-810C Wireless Digital Detector includes built in shock detection function which detects the shock applied to the detector unit and also the free fall of the detector unit. The data saved in the detector is transferred to the PC, can be output to .csv file and used for analysis.

Includes:

2 - Battery Packs

1 70C/701C Series Wireless Snap-on 14 x 17, 8:1, 132lpi, 40-72" Focus Lightweight Protect-A-Grid with Handle

1 70C/701C Series Wireless Mobile DR Panel Holder

Featuring a handle and a positive lock, this item offers additional drop protection and allows the radiographer to easily carry the Canon CXDI-701C Wireless Detector from room to room.

Product Advantages Lightweight plastic Ergonomic handle Double positive lock Drop protection Cable management Smooth non-porous surface Curved corners Specifications: - H 18.5", W 18.5", D 1"

1 Applications Training - Three (3) Days/Twenty-four (24) Hours Technologist Training

$220,747.00

AMMHINWARDM

Sticky Note None set by AMMHINWARDM

AMMHINWARDM

Sticky Note MigrationNone set by AMMHINWARDM

AMMHINWARDM

File details come from the government source that posted it.