Line # Description Qty
Affiniti 70 G System 11 Affiniti 70 GI System
Affiniti features an uncompromised level of clinical performance to meet the challenges of today’s busy ultrasound practices
• New tablet like interface revolutionizes how you interact with the system resulting in a reduction in exam reach and exam steps.
• Large 21.5-inch high definition LCD display mounted on fully articulating extension arm for easy viewing in virtually any environment
• Infinite articulation of control panel and monitor allows for perfect alignment whether sitting or standing (180 degrees of freedom from center) to scan ergonomically
• Almost silent when running (37-41dB) – equivalent to the sound of a library
• 4 transducer ports
• Integrated footrest
• Integrated storage shelves and drawer
• 4 wheel swivel and swivel/brake lock control
• Up to 4,718,592 total digital channels
• Exclusive adaptive signal to noise ratio that achieves system dynamic range of up to 280 dB for improved 2D
• Powerful distributed multi-core processing architecture capable of achieving 225 x 109 40-bit Multiply-Accumulates/second. Includes 512 GB hard drive
• Windows Embedded Standard 7 Operating System
• Philips Next Generation SonoCT Real-Time Compounding, with Widescreen capability and up to 9 beam-steered lines of sight that acquires more information and reduces angle-generated artifacts
• Philips next generation XRES Adaptive Image Processing for noise and artifact reduction to improve tissue and border definition
• Fully independent, multiple mode Triplex operation
• Vascular High-Q Automatic Doppler provides real-time tracking of Doppler signal, automatically selecting the highest peak velocity and with the touch of a button, adding measurements to your report.
Transducers Advanced Compact connector technology offers pinless design for exceptional reliability and performance
• Ergonomic designs with lightweight flexible cables
• New low-loss technology for better penetration with fewer artifacts
• Breakthrough frequency bandwidths and array configurations
• Supports array configurations up to 20 MHz – sector, linear, curved, tightly curved, TEE and mechanical volume transducers
REQUESTING SERVICE: ORTHOPEDICS(112)
DEL. TO: NX/ORTHO CLINIC
SHIP TO:
CHIEF, A&MM (90) B93012
V.A. Medical Center
113 HOLLAND AVE
ALBANY, NY 12208-3410
P.O.# 528-B93012
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
Sticky Note Unmarked set by AMMHINWARDM
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
Sticky Note Unmarked set by AMMHINWARDM
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
Sticky Note Unmarked set by AMMHINWARDM
Automation Designed with our most innovative tools to maximize efficiency
• Autoscan (real time iSCAN) automatically optimizes gain and TCG continuously to assure you are achieving an optimal image in 2D, 3D and 4D.
• Vascular High-Q Automatic Doppler provides real-time tracking of Doppler signal, automatically selecting the highest peak velocity and with the touch of a button, adding measurements to your report
• Intelligent Tissue Specific Imaging
• Application-specific and user definable Quicktext Automatic Annotation
• QuickSAVE User Defined Programs (up to 45 per transducer)
Data
• On-board workstation-class data management with thumbnail previews and storage of images, loops
• and reports
• Retrospective and prospective clip capture to internal drive or removable media
• Ability to send X,Y & Z volume MPR's to most PACS
• Ability to export
• QLAB native data
Other Core Features
• Abdomen clinical option
• Battery back-up
• Color Power Angio
• Tissue Harmonics and Pulse Inversion Harmonic Imaging
• 2D, M-Mode, Anatomic M-mode, Color Flow Doppler, Pulsed Wave Doppler (PW), High
PRF PW Continuous Wave Doppler, Chroma Imaging, Tissue Doppler Imaging, Pulse Inversion, Cineloop Image, M-mode and Doppler Review
• High Definition Write Zoom and Read Zoom with pan features
• Chroma Imaging
• Measurement tools including: distance, depth, area, and circumference
• Volume Flow Measurements
NetLink Dicom Provides network print and store, commit, modality worklist, and structured reporting for adult and pediatric echo, vascular, and OB/GYN. Integrated Wireless DICOM with WEP2 security capability.
Also enables DICOM Query and Retrieve (optional capability).
Easy-clip Cable Mgmt Solution Unique cable management system that keeps cables tangle and damage-free, while also decreasing cable strain for greater operator comfort while scanning. Two easy-clips included;
enough for four transducers.
Safeguard This is a standard computer administration tool used to prevent unauthorized programs (malware) from running on the ultrasound system.
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
Security Plus Security Plus provides a Defense-in-depth strategy implementing security features designed to help healthcare facilities provide additional patient data privacy, and protection from unauthorized access via the ultrasound systems on hospital networks. New data security enhancements will make EPIQ and Affiniti compatible with data security on medical devices. Requires Evolution 2.0 or later. This feature does not include or require SafeGuard (malware protection).
Freehand 3D Allows acquisition of 3D freehand uncalibrated data with any linear or curved array probe except motorized transducers
Clinical Education
***2 days of Implementation Onsite Training (expires 90 days after install, provided Mon-Fri during normal business hours) and an E-Learning subscription; Basic System Training course for two people (expires 180 days after install).
***Note: Philips Healthcare personnel are not responsible for actual patient contact or operation of equipment during education sessions except to demonstrate proper equipment operation. The training sessions should be attended by the appropriate healthcare professional as identified by the department director. Repeat training for staff non-attendance will not be accepted. Site must be patient-ready to meet training expectations.
BST ONLINE COURSE (qty 2) –The Basic System Training e-learning curriculum is focused on your Philips Ultrasound System. The aim of this comprehensive series is to provide the Sonographer/Echocardiographer with a comprehensive bundle of self paced courses to familiarize you with your ultrasound system.
Promo Affiniti Online Bundle This promotion provides a subscription for one person to access one of the four following online eLearning options: (1) Cardiac Echo online courses, (2) Women's Healthcare online courses, (3) General Imaging online courses, OR (4) Vascular online courses.
The goal of the curricula is to provide the Sonographer/Echocardiographer with a comprehensive bundle of self-paced courses covering relevant topics. This online tuition expires 180 days after the system install.
Government Security 12 Required by all DoD customers. This option disables VNC capabilities (which if enabled would provide remote desktop support) for increased security of data.
Musculoskeletal Clinical Option
The Musculoskeletal Clinical Option was developed to support the expanding application area of musculoskeletal ultrasound. The musculoskeletal Tissue Specific Imaging settings support high resolution broadband transducers including L18-5, L12-5 50mm, L12-4, L12-3 L15-7io and eL18- 4 (Affiniti 70) ; L18-5, L12-5 50mm, L12-4, and L15-7io (Affiniti 50); and L12-5 50 nd L12-4 (Affiniti 30). These TSI settings enable clinicians to select General or Superficial imaging setting.
L15-7io Transducer 14 Compact high resolution linear array transducer with 15 to 7 MHz extended operating frequency range for intraoperative vascular imaging. Also supports high-resolution superficial venous and arterial studies, pediatric radiology, and small parts applications.
eL18-4 Transducer with EM Trackers
Ultra-broadband 18-4 MHz PureWave Linear multi-row array transducer with fine elevation focusing. This transducer incorporates integrated EM (electro-magnetic) tracking coils for AI Breast and Fusion/Navigation compatibility. This transducers supports a broad range of high resolution applications including breast, small parts, vascular and musculoskeletal imaging. Also supports pediatric and specialty OB imaging. The eL18-4 transducer features exceptional imaging performance and supports advanced clinical tools such as strain elastography, MicroFlow Imaging and precision biopsy capabilities.
English Manual 16 Operation Manual
Promo Affiniti Online Bundle 17 This promotion provides a subscription for one person to access one of the four following online eLearning options: (1) Cardiac Echo online courses, (2) Women's Healthcare online courses, (3) General Imaging online courses, OR (4) Vascular online courses. The goal of the curricula is to provide the Sonographer/Echocardiographer with a comprehensive bundle of self-paced courses covering relevant topics. This online tuition expires 180 days after the system install.
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
Sticky Note Unmarked set by AMMHINWARDM
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
Sticky Note Unmarked set by AMMHINWARDM
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
Sticky Note Unmarked set by AMMHINWARDM
AMMHINWARDM
Sticky Note None set by AMMHINWARDM
AMMHINWARDM
Sticky Note MigrationNone set by AMMHINWARDM
AMMHINWARDM
File details come from the government source that posted it.