Attachment _Technical Specifications (MCPV).docx
DOCX document 22 KB Posted
- Solicitation number
- 26-R-0000194
About this file
This is a Technical Specifications document for a Tier 2 Mobile Command Post Vehicle (MCPV) Gooseneck Trailer system. The specifications define the requirements for design-build solutions that will serve as self-contained, rapidly deployable mobile command, control, communications, and computing (C4) platforms. The systems must accommodate approximately 15-20 workstations and integrate advanced communications technologies including satellite, RF, and cellular capabilities, onboard power generation, and configurable workspace infrastructure. Key design requirements emphasize modularity, scalability, interoperability, and long-term maintainability to support wide-ranging mission-critical operations across the Federal Bureau of Investigation.
The Federal Bureau of Investigation is conducting market research through an RFI/Sources Sought Notice (Solicitation Number 26-R-0000194) with a response due date of May 4, 2026. The Government is considering a performance-based acquisition approach under a potential Indefinite Delivery/Indefinite Quantity (IDIQ) contract vehicle. Industry responses should address technical capabilities and innovative design approaches, integration of communications/power/vehicle systems, production capacity and delivery timelines, lifecycle sustainment and support strategies, and recommended contract structures. This is a pre-solicitation market research effort issued for information and planning purposes only; the Government does not intend to award a contract based on this RFI and will not reimburse respondents for proposal preparation costs.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFI_Tier 2 MCPV Trailer (UPDATED).pdf | ||
| PWS_Tier 2 MCPV Trailer_22JUN26 (DRAFT).docx | DOCX document | |
| RFI_Tier 2 MCPV Trailer (UPDATED).pdf | ||
| RFI_Tier 2 MCPV Trailer.pdf | ||
| RFI_Tier 2 MCPV Trailer.pdf | ||
| RFI_Tier 2 MCPV Trailer.pdf | ||
| PWS_Tier 2 MCPV Trailer (DRAFT).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT 1:TECHNICAL SPECIFICATIONS TIER II MOBILE COMMAND POST VEHICLE (MCPV)
1.0 GENERAL
1.1 The Contractor shall provide a custom-engineered Tier II Mobile Command Post Vehicle (MCPV) system consisting of a gooseneck trailer and, when ordered, a fully integrated prime hauler vehicle.
1.2 The MCPV shall be designed, engineered, manufactured, integrated, tested, and delivered as a complete operational system.
1.3 The MCPV shall support command, control, communications, and computer (C4) operations in support of FBI missions.
1.4 The expected operational service life of the MCPV shall be a minimum of fifteen (15) years.
1.5 The Contractor shall maintain a current ISO 9001 certification throughout contract performance.
2.0 PRIME HAULER REQUIREMENTS (WHEN ORDERED)
2.1 The Contractor shall provide a Class 4 prime hauler vehicle (Ford F-450 or equivalent).
2.2 Minimum Requirements:
1. Dual rear wheel configuration;
1. Four-door crew cab;
1. Seating capacity for five personnel;
1. Minimum 500 horsepower diesel engine;
1. Minimum 1,000 ft-lb torque;
1. Automatic transmission, minimum ten (10) speeds;
1. Minimum forty (40) gallon fuel tank;
1. Silver exterior color;
1. Power seats with lumbar support;
1. LED headlights and fog lights;
1. AM/FM/Bluetooth audio system;
1. Apple CarPlay and Android Auto compatibility;
1. Minimum ten-inch navigation display;
1. 360-degree camera system;
1. Lane departure warning and parking sensors;
1. Front bucket seats and center console;
1. Power windows and locks;
1. Adjustable steering wheel with integrated controls;
1. Vehicle alarm system;
1. Spray-in protective bed liner.
2.3 Emergency Equipment
The Contractor shall provide:
1. Whelen or equivalent emergency lighting;
1. Public address system;
1. Motorola APX-8500 radio installation;
1. Trailer camera display system;
1. Trailer side and rear camera integration.
2.4 Integration
The Contractor shall ensure full interoperability between the prime hauler and MCPV trailer including:
1. Emergency lighting controls;
1. Generator integration;
1. Fuel system integration;
1. Camera systems;
1. Communications systems;
1. Trailer umbilical systems; and
1. Safety systems.
3.0 GENERATOR SYSTEM
3.1 The Contractor shall provide a diesel generator system sized to support the full electrical load of the MCPV while operating at no greater than eighty percent (80%) rated capacity.
3.2 Generator Requirements
1. Diesel fueled;
1. Weatherproof enclosure;
1. Sound attenuated;
1. Vibration isolated;
1. Serviceable installation;
1. Minimum twenty (20) gallon fuel tank;
1. Three-phase 208V shore power capability;
1. Cam-Lok E1016 connectors;
1. Fifty (50) foot shore power cable.
3.3 Fuel System
The generator shall:
1. Operate from integrated fuel tank;
1. Operate from prime hauler fuel tank;
1. Include three-way fuel selector valve;
1. Include fuel shutoff capability.
4.0 MCPV TRAILER CHASSIS
4.1 General
1. Maximum overall length: 45 feet;
1. Maximum width (stowed): 8 feet 6 inches;
1. Maximum Gross Trailer Weight: 26,000 pounds;
1. Maximum pin weight: 5,000 pounds.
4.2 Chassis Requirements
1. Gooseneck design;
1. Rear chamfer;
1. Minimum two axles;
1. Air ride suspension;
1. Backup air supply capability;
1. Electric brakes;
1. Electric/hydraulic leveling system;
1. Hydraulic landing gear capable of lifting the trailer.
4.3 Wheels and Tires
1. Matching wheels and tires;
1. Aluminum, polished, or powder-coated wheels;
1. Tires rated for trailer load;
1. Tires rated for speeds exceeding 75 mph;
1. One matching spare wheel and tire.
5.0 TRAILER INTERIOR CONFIGURATION
5.1 Occupancy
The MCPV shall support fifteen (15) to twenty (20) simultaneous users.
5.2 Layout
The interior shall include:
1. Front and rear personnel entry doors;
1. Ability to divide the interior space into a 60/40 configuration;
1. Interior separation wall with door;
1. Conference table seating four to six personnel;
1. Minimum fifteen workstations;
1. Minimum four interior video displays.
5.3 Interior Design
The Contractor shall minimize interior obstructions and maximize usable workspace.
6.0 CONSTRUCTION REQUIREMENTS
6.1 Exterior Construction
1. Minimum .090 aluminum skin;
1. Minimal seams;
1. No exposed rivets or screws where practical;
1. Silver paint with blue stripe;
1. Diamond plate or equivalent rock guard.
6.2 Doors
1. Alarmed personnel and storage doors;
1. Medeco keyed-alike locks;
1. Windows with blackout capability;
1. Integrated retractable steps;
1. Handrails.
7.0 ELECTRICAL SYSTEMS
7.1 General
All wiring shall:
1. Be protected from abrasion;
1. Be installed in conduit, raceways, or flexible duct;
1. Be labeled at both ends;
1. Be accessible for future maintenance.
7.2 Data Cabling
1. CAT-8 shielded cable;
1. T568B termination;
1. Color-coded network drops;
1. Individually numbered ports.
7.3 Workstations
Each workstation shall include:
1. Three CAT-8 network ports (Red, Green, Blue);
1. One duplex electrical outlet;
1. Two USB-C charging ports.
7.4 Electrical Outlets
The MCPV shall include:
1. External 15 amp night service receptacle;
1. One curbside 220V receptacle;
1. UPS-supported receptacles as required.
8.0 INPUT/OUTPUT PANELS
8.1 The Contractor shall provide lockable I/O panels on:
1. Curb side;
1. Street side;
1. Roof.
8.2 Each panel shall include:
1. USB charging ports;
1. HDMI ports;
1. RF ports;
1. RJ-45 network ports;
1. AC power outlets;
1. Fiber connections;
1. Interior illumination.
9.0 MAST SYSTEM
9.1 Minimum Requirements
1. Pneumatic mast;
1. Minimum thirty (30) foot height;
1. Minimum 200-pound masthead capacity.
9.2 Mast Cabling
1. CAT-8 cabling;
1. LMR-240 cabling;
1. AC power;
1. DC power.
9.3 Mast Equipment
1. Two HD PTZ cameras;
1. Cellular antenna;
1. 4.4-5.0 GHz antenna;
1. Safety strobe light.
10.0 EXTERIOR SYSTEMS
10.1 Awnings
1. Curb side awning;
1. Awnings over personnel doors;
1. LED lighting;
1. Automatic retract capability.
10.2 Exterior Video Display
1. Minimum 55-inch HD display;
1. Weatherproof compartment;
1. Wi-Fi and Bluetooth disable capability.
10.3 Exterior Lighting
The Contractor shall provide:
1. Emergency lighting visible from all directions;
1. LED marker lights;
1. Scene lighting;
1. Storage compartment lighting.
10.4 Exterior Security Cameras
1. Front, side, and rear cameras;
1. 360-degree coverage;
1. PTZ capability;
1. Infrared capability.
11.0 ROOF REQUIREMENTS
11.1 General
1. Maximum overall height: 13 feet;
1. Walk-on roof;
1. Slip-resistant surface.
11.2 Safety
1. Twelve roof tie-down points;
1. Foldable safety rails.
11.3 Antenna Provisions
1. RF antenna mounts;
1. Cellular antenna mounts;
1. Starlink mounting provisions;
1. Television antenna.
12.0 ENVIRONMENTAL SYSTEMS
12.1 HVAC
1. Ducted air conditioning;
1. Equipment rack cooling;
1. Thermostat controls.
12.2 Heating
1. Electric baseboard heating or equivalent;
1. Thermostat controls.
12.3 Safety
1. Smoke detectors;
1. Carbon monoxide detectors;
1. Fire extinguishers.
13.0 EQUIPMENT RACKS
13.1 General
1. Four-post racks;
1. Shock mounted;
1. Expansion capability;
1. Internal and external access.
13.2 Rack Components
The Contractor shall provide infrastructure supporting Government-installed equipment including:
1. UPS systems;
1. Power strips;
1. Patch panels;
1. Shelves;
1. Cable management;
1. RF patch panels;
1. Data patch panels.
14.0 INTERIOR FINISHES
14.1 General
1. Minimum interior headroom: 6 feet 8 inches;
1. Insulated floors, walls, and ceiling;
1. Sound dampening materials.
14.2 Storage
1. Overhead cabinets;
1. Secure laptop storage;
1. Equipment storage.
14.3 Interior Lighting
1. Dimmable LED lighting;
1. Under cabinet lighting.
14.4 Sound Levels
Interior sound levels shall not exceed sixty (60) dBA while operating HVAC and generator systems.
15.0 MONITOR SYSTEMS
15.1 Interior
1. Minimum four 50-inch displays;
1. HDMI 2.1 capability;
1. Matrix switching compatibility.
15.2 Exterior
One exterior monitor shall be provided.
16.0 FLEET TRACKING AND SITUATIONAL AWARENESS
16.1 The Contractor shall provide a fleet management system independent from Government networks.
16.2 The system shall provide:
1. GPS tracking;
1. Web-based monitoring portal;
1. Slide position monitoring;
1. Door status monitoring;
1. Mast position monitoring;
1. Fault reporting capability.
17.0 INSPECTION, TESTING, AND ACCEPTANCE
17.1 The Government reserves the right to conduct inspections during fabrication.
17.2 Final acceptance shall occur at the Contractor’s facility.
17.3 The Contractor shall successfully complete:
1. Functional testing;
1. Electrical testing;
1. Environmental testing;
1. Network testing;
1. Road testing (minimum 50 miles).
18.0 DELIVERABLES
The Contractor shall provide:
1. As-built drawings;
1. Structural drawings;
1. AC, DC, RF, and data wiring diagrams;
1. Programming files;
1. Software licenses and credentials;
1. Equipment manuals;
1. Training materials;
1. Warranty documentation.