224112 Chain Link Fence- SOW- REVISED.pdf
PDF 3 MB Posted
- Attached to
- CBJTC SR16 Chain Link Fence
- Solicitation number
- ITB-15335
- Issued by
- St. Johns County, Florida
About this file
This Scope of Work document issued by the Directorate of Public Works at Camp Blanding Joint Training Center, a Florida Army National Guard facility, outlines the removal and replacement of approximately 5,784 linear feet of chain-link fencing, including terminal posts, line posts, barbed wire, and two 30-foot manually operated cantilever gates located at 5629 State Road 16 West in Starke, Florida. The new fencing will be black vinyl, 6 feet high with 1 foot of barbed wire with black vinyl coating above the fence, installed in accordance with USACE FE6-TR-72 Chain-Link Security Fence specifications and CBJTC Fencing Standards. An addendum alternative (ABI 1) provides for 7-foot high fencing with identical barbed wire configuration. All fence posts must be set in concrete with horizontal cross bars at the top and tension wire at the bottom. The non-mandatory pre-bid meeting and site visit are scheduled for March 24, 2026, at 10:00 a.m. at the project location, with the deadline for bidder questions set for March 31, 2026, at 12:00 p.m. A tentative final addendum will be published on April 3, 2026, and sealed bids will be publicly opened and read aloud on April 21, 2026, at 2:00 p.m. at the Robert F. Ensslin National Guard Armory in St. Augustine, Florida. The project must achieve substantial completion within 120 calendar days after the Notice to Proceed, with liquidated damages assessed at $250.00 per calendar day for delays beyond the required completion date.
The estimated contract value is between $100,000 and $300,000, and bidders must submit a good faith deposit equal to 5 percent of the bid amount via bid bond from a surety insurer authorized in Florida, or a certified or cashier's check accompanying the bid. Upon contract award, Performance Bonds and Labor and Material Payment Bonds equal to 100 percent of the contract sum are required and must be registered with the county within 10 days of award. The procurement is funded by State Fiscal Recovery Funds made available through the American Rescue Plan Act and is subject to federal compliance requirements. All bidders must have a Unique Entity Identification (UEID) from SAM.gov or evidence of application at the time of bid opening and must comply with federal debarment and suspension regulations. Bidders must possess appropriate Florida state licenses or certifications, demonstrate comparable project experience with at least two successful chain-link fencing projects completed within the last five years, and establish a local office within 300 miles of the project site. The contract requires compliance with prevailing wage requirements, E-Verify employment verification, use of Florida products where quality and pricing are equal, criminal history background checks for all employees, and 24-hour site security. Proposals are valid for 60 calendar days from bid opening, and the selected contractor must enter into a formal written agreement within 10 calendar days of contract award.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DIRECTORATE OF PUBLIC WORKS
CAMP BLANDING JOINT TRAINING CENTER
FLORIDA ARMY NATIONAL GUARD
5629 STATE ROAD 16 WEST, BUILDING 2300
STARKE, FLORIDA 32091-9703
CBJTC-DPW 21 January 2026
MEMORANDUM FOR: Environmental Review
SUBJECT: SCOPE OF WORK 224112 CBJTC SR 16 Chain Link Fence Replacement
Remove and replace approximately 5,784 LF of chain-link fencing, terminal post, line post, barbed wire, and (2) 30’ ft. manually operated cantilever gates.
New fencing will be installed in accordance with USACE FE6-TR-72 Chain-Link Security Fence specifications and CBJTC Fencing Standards.
• The new fencing and gates will be black vinyl, 6’-0” high with 1’-0” of barb wire with black vinyl coating above fence.
• All gates to be replaced with the same configuration as existing.
• All gates will be manually operated.
• All fence post will be set in concrete
• Fencing to have horizontal cross bar at top and tension wire at the bottom.
ABI 1 - The new fencing and gates will be black vinyl, 7’-0” high with 1’-0” of barb wire with black vinyl coating above fence.
Design services were not utilized for this project.
Suzanne D. McRee Project Manager
Attachments:
•USACE FE6-TR-72 Chain-Link Security Fence specifications •CBJTC Design and Construction Standards •Project Site Map •Project Utility Map
5,784 LF Chain Link Fencing
LEGEND
(2) 30’ Cantilever Gates
224112 CBJTC SR 16 Chain Link Fence Replacement
CAMP BLANDING
FACILITIES DESIGN
AND
CONSTRUCTION
STANDARDS
DEPARTMENT OF PUBLIC WORKS
CAMP BLANDING JOINT TRAINING CENTER
FLORIDA ARMY NATIONAL GUARD
5629 STATE ROAD 16 WEST
BUILDING 2067
STARKE, FLORIDA 32091
APRIL 2021
CAMP BLANDING FACILITIES DESIGN AND CONSTRUCTION STANDARDS
DIVISION 2 - SITE WORK
SECTION 02444 - CHAIN-LINK FENCING AND GATES
1. MATERIALS / INSTALLATION
A. Construction Fencing: Construction fencing is not required on post. Site and materials security is the sole responsibility of the Contractor. If desired, the Contractor may provide eight foot tall temporary chain-link fencing with secured post and lockable gates around all construction sites and storage areas. The fencing shall be installed plumb, level and secured to avoid the top of the fencing from leaning outward into pedestrian circulation paths. All exposed sharp edges shall be folded over to avoid the potential for inflicting injury.
B. Movable temporary chain-link fence panels are allowed to be used during construction with approval of the CBJTC Project Manager. When using movable panels, care must be taken to avoid protrusion and tripping hazards presented by the “Feet” of the fence support panels.
C. Fencing: When used on Post, chain-link fencing shall have hot dipped galvanized schedule 40 tubular steel framing, a top rail and bottom tension wire. The terminal post shall be a minimum of 2-1/2” outside diameter. The line post shall be a minimum of 2” outside diameter. The gate post shall be a minimum of 3” outside diameter. The top rails and bracing shall be a minimum of 1-1/2” outside diameter. All gate post and line post shall be installed in concrete with the top of the concrete being level with grade and crowned for drainage. The chain-link fabric shall be galvanized/black vinyl coated 2” mesh with tension wire at bottom. Mesh will be attached to posts and rails with 9 gage steel wire. All accessories shall be provided for a complete operation and as required for reinforcement. In general, fencing shall slope to follow the ground plane.
D. High-Security Chain Link Fencing: Security-type fence must be at least 6 feet high, galvanized/black vinyl coated nine gauge, chain-link metal fabric with twelve inch high, three-strand four-point barbed wire 45 degree anti-climbers to enclose the secure areas.
Vehicle gate(s) may be swinging or rolling. The following areas should be provided with security fencing: military vehicle parking; fuel storage and dispensing systems; service and access aprons; aircraft parking; wash platforms; lubrication and inspection racks;
covered, unheated storage; cannibalization areas; and loading ramps. Fencing should be located no more than five feet from the edge of the paved areas unless safety or security demands a greater distance.
E. Gates: Where required, gates will be installed to accommodate passage of vehicles and/or personnel. Gates shall be sized to allow access by CBJTC Maintenance equipment and military vehicles. Coordinate gate sizes with CBJTC-DPW. Gates shall be constructed in the same manner as surrounding fencing unless otherwise directed by
CBJTC.
END OF SECTION 02444
CHAIN-LINK FENCING AND GATES 02444-1
1626755697.NFG
Highlight
1626755697.NFG
Highlight
D
C
TRUSS ROD ANO BAND
A
BAA8EO-WIRE APRON Or.I
EXTEHSION AAMS
10°-0" MAXIMUM
CHAIN-LINK SECURITY FENCE DETAIL
<-::l),..�, I""'\,''""°" ...
�CAARIAGE80t.l
BRACE RAIL CLAMP DETAILS_
'2!!;.
P�OC 81tQC[ PANEL WHENE\'CR STIIAICHT RUNS CXCEEO 500 rccr.
ENO OR GATE POST DETAIL_
TENSION BAND OEfAIL_
FASTENING DETAlLS.
��cw, � srru CAOUND
GROUNDING DETAIL
rtNCE POSl f8 AWC SOlJO COPPER
\\1RE
MOLOEO [XOTH[RM•C WELD
OR APPROVED ClAW'-TYPE FIT!INC or COPPER
9-0AG£Slttl.Tl[ WIR[S
(2·-0• O.C. MAX.}
9-GAGE STEt:� TlE WIRE (l!t O.C.
W.X. ANO WITH:N
-4" FROM TOP ANO
80TT0t.l or rASRIC)
UNE PQ§T ATTACHMENT§
EXTENSION ARM DETAILS_
ND SCAlE
USEAtfJSECTION
COANCR, ENO & PUU. POSTS
STEELPOSTOCHEDULE
MINIMLN OIJTStDEDIMENSIONS (NOMINAL)
FABRIC LESS 'THAN 7T FABRIC 7Z' TO 915" FABRIC OVER 98"
TUBULAR - ROUNO 2,J7S" 0,0. 2.87!)"0.0,
2.50" so.
J.50" X 3.50"
4.00" 0.0.
J.oo· so. TUBULAR - SOUAFI£ 2.ocr so.
C-S[CTION (ROLL-FOAM[O) J,50" X .l.50"
H-SCCTION
C-SECTION (ROU.-FORMEO)
TOP. BOTTOM & BRACE AALS
Tl.leUI.AR - ROONO TUBULAA -Sou..RC
N-SCCTION
C-SECTION (ROU.-FOAMEO)
9-(;AG[ STCCl TI[
�!'.(1!1"0.C. MAX.
A."10 WITHIN 4" HIOM
TOP ANO 90TTOM
Of'FAEIRICJ
1.90" o.o.
2.2s·x1.10· l.87S"Xl.625"
2.J75" 0.0.
2.2s·x1.10· 2.2s·x1.10·
1.66" o.o.
1.so· o.o.
1.e2s·x1,so• 1,62S"X1.2!'.i"
2.875"0.0.
2.2s·x10·
I. 0£T�LS SHOWN AR[ TO CLARIFY R[OUIREM[NTS ANO AR[ NOT INTENO[O TO
UMIT 0Tt£R TYPES OF' FENCE SECTIONS � M[lllOOS Of' INSTAU.AllON.
2. WIR[ TIES. RAC;, POSTS. ANO CRi.CES SWJ.L 8[ CONSTRVCTECI ON TH[ S[CUR[ SIi)[ or THE FENCE AUCNMEHT. CHAIN-UNI( FABRIC SHAlL BE PLACED ON THE
�POSIT[ SID[ OF THC SECURE ARE,\.
3. UNLESS SF'E:�ICM.I.Y SHOWN OR SPcc.-ico. ALL FE6 FENCE SHALL HAYE 1'N APRON EXTENOEO OUTWARO FROM THE ARCA BEINC PROT[Cl[O.
4. C-SECTION POSTS SHAU. BE INSTAU.£0 SO THAT TH[ \()10 INSIOE TH£ POST
IS COMPLETO..Y ALLEO WITH CONCRETE UP TO THE TOP or TH[ rouNOATION.
FENCE I EGENP·
Tl'P[ res - CI-WN-LINI( ftNC[ WITHOUT 8AR8E0-Wfi[ APRON TYPE f[6 - CHAIN-LINI< r[MC[ W/8ARBE0-WIR[ ON SINCL[ OUTRICCt:R TYPE rE7 - CHAIN-UNI< FENCE W/8AABEO WIRE ON OOU8L[ OUTRICCCR Wf'[ F[8 - CHAIN-UNI< FfNC[ W/8AR8[0-WIRC ANO 8AA8E0-TAP[ ON OOUBl[
OVTRICCER
TR - FENCE WITH TOP RAIL MIO TENSION WIR[ AT BOTTOr.l TER - FENCE WITH TOP NfO BOTTOM RNlS TW8 - TtHSION -.,1RE TOP ANO BOTI'OM TWBR r FENCE WITH TOP TENSION WIRE ANO BOTTOM RAIL FINAL NUVO(R IS FABRIC YIIOTtl IN !NCH[S.
E.�ES
FE6-TR-72 - CHAIN-UNI< SCCURITY FENCE WITH l!AABEO-WIRE ON SINCL[
OUTRIGCER. TOP RM.. A"IO 72 INCH FA8R1C WIDTH .
H5-TY,1:1-48 - Ct'.AIN-UNIC SECURITY FENCE WITH NO PPROH, TOP ,oNO BOTTOM TENSION WIR[. ANO 48 INCH r,oaRIC WIDTH, $$ -THINK VALUE ENGINEERING-$$
U.S.-lk»NeutOISl'RICT CO!l"Of'IENGINESl8
D
C
' A STANDARD oeTAILSFORCHAlf4.LINK
SECURITY FeNCES
AND FARM STYLE R:NCES
FES CHAIN-LINK
SECURITY FENCE DETAILS
1511372883.NFG
Highlight
*GATE LENGTH AND SIZE COULD CHANGE PER PROJECT
| 224112 SR16 Chain Link Fence Restoration_ Procurement Request for Construction_22 JAN 26.pdf |
| 224112 SR16 Chain Link Fence Restoration_ Procurement Request for Construction_22 JAN 26.pdf |
| 224112 _ 420 SR 16 Chain Link Fence Replacement_06 FEB 26.pdf |
| 224112 _ Scope of Work.pdf |
| 224112 _ Rec and Check CBJTC SR 16 Chain Link Fence Replacement_21 JAN 26.pdf |
| 224112 _ Rec and Check CBJTC SR 16 Chain Link Fence Replacement.pdf |
| 224112 _ Rec and Check CBJTC SR 16 Chain Link Fence Replacement.pdf |
| 224112 _ Scope of Work.pdf |
| 224112 Site Map.pdf |
| Slide 1 |
| 224112 Utility Map.pdf |
| CBJTC Cantilever Gate and Fence Spec_.pdf |
| FE6-TR Fence Standard.pdf |
| 224112_420_CBJTC SR 16 Chain Link Fence Replacement_ENV.pdf |
| REC_224112_CBJTC SR16 Chain Link Fence Replacement 1.pdf |
| REC_224112_CBJTC SR16 Chain Link Fence Replacement 2.pdf |
| REC_224112_CBJTC SR16 Chain Link Fence Replacement 3.pdf |
| REC_224112_CBJTC SR16 Chain Link Fence Replacement 4.pdf |
| REC_224112_CBJTC SR16 Chain Link Fence Replacement 5.pdf |
| REC_224112_CBJTC SR16 Chain Link Fence Replacement 6.pdf |
File details come from the government source that posted it. Updated .