220042 As Built Drawings.pdf

PDF 12 MB Posted

Attached to
WWYK250063 - INSTALL REACT VII FACILITY, B9001, POST V19
Solicitation number
FA813726R0026
Issued by

About this file

This document set consists of construction drawings and a fire alarm system design for the TAFB B9001 Micro Foundry Expansion project under Contract No. W912BV22R0015. The general contractor is responsible for all construction depicted across architectural, mechanical, electrical, and structural drawings, including site preparation, building demolition, floor systems, roof framing, HVAC installation, plumbing, fire protection, and electrical distribution.

The fire alarm system design, prepared by Johnson Controls, modifies the existing fire alarm system to add a new duct smoke detector with sampling tube on RTU-18V-1 in the Sand Mold Printer Lab, a shut-down relay, and a remote test station connected to existing Node 18 TPR1. The system utilizes Simplex addressable devices including photo smoke sensors, duct smoke detectors (Models 4098-9755 and 4098-9756), manual pull stations (4099-9006), relay IAM modules (4090-9002), notification appliances with varying candela ratings and speaker configurations, and addressable sounder bases. All wiring must comply with NFPA 72 and applicable electrical codes, with power-limited circuits installed in Class B configuration. The design accommodates 38 addressable points across multiple notification appliance circuits and IDNet signaling lines, with battery backup calculations provided for two transponder units. Installation requirements include maintaining fire resistance integrity, protecting devices from dust contamination during construction, daily as-built drawing updates, and coordination with existing fire alarm systems to prevent service disconnection without written owner approval.

View the file

Other files

File Type Posted
250063_ATT 10_Submittal Register.xlsx XLSX spreadsheet
26 05 73 POWER STUDIES.pdf PDF
26 20 00.pdf PDF
09 90 00.pdf PDF
23 09 13.pdf PDF
23 36 00.00 40.pdf PDF
08 71 00.pdf PDF
05 40 00.pdf PDF
10 14 00.10.pdf PDF
08 33 23.pdf PDF
08 11 13.pdf PDF
07 92 00.pdf PDF
01 33 16.00 10.pdf PDF
01 32 16.00 20.pdf PDF
image.png PNG image
250063 React VII_Hardware schedule 25MAR26 JL.xlsx XLSX spreadsheet
JOIST SPECIAL INSPECTIONS.xlsx XLSX spreadsheet
ELECTRICAL PANEL SCHEDULE U18L.xlsx XLSX spreadsheet
esvEH_singledual_2023_V2.pdf PDF
lk406gn05t4_spec.pdf PDF
2_-_HE05-JINV-S11EE---GNT---L_001.pdf PDF
ERV Schedule_TAFB B9001_O-212477.xlsx XLSX spreadsheet
4500-CIVIL.pdf PDF
250063_ATT 10_Submittal Register.pdf PDF
250063_ATT 9_SOW.pdf PDF
250063_ATT 11_Drawings.pdf PDF
WWYK250063-04March2026.pdf PDF
2020 TAFB Facility Standard.pdf PDF
2026 TAFB Electrical Standard - Signed.pdf PDF
SOW Att 02a_Controlled Area Training.pptx PPTX presentation
SOW Att 02c_Controlled Area Training - Certificate.pdf PDF
22 00 00.pdf PDF
28 31 76.pdf PDF
23 09 23.02.pdf PDF
07 14 00.pdf PDF
08 51 23.pdf PDF
10 44 16.pdf PDF
07 21 16.pdf PDF
00 72 00.pdf PDF
00 71 00.pdf PDF
01 78 00.pdf PDF
01 33 00.pdf PDF
000_TABLE OF CONTENTS.pdf PDF
01 78 23.pdf PDF
esvperf_singledual_2023_V2.pdf PDF
lrad331965pd_spec.pdf PDF
REACT VII SA-01.pdf PDF
TAFB B9001 VAV Schedule.pdf PDF
ARCH-COMBINED.pdf PDF
4500-MUG.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R U

N W

AY

8/

RUNWAY 13/31

TA

XI

W

AY

G

TAXIW

AY H

TAXIW

AY H

TAXIWAY B

TAXIWAY C

TAXIWAY M

TAXIWAY M

TA

XI

W

AY

K

TAXIWAY ETAXIWAY

TAXIWAY AWAYTAXIWAAXIW

TA

XIW

AY E

E

TA

XIW

AY

TAXIWAY F

TAXIWAY D

TAXIWAY E

TAXIWAY J

TA

XI

W

AY

GG

TAXIWAY A

TAXIW

AY H

TAXIWAY CC

TAXIWAY D

TAXIWAY EE

AXIWAY EE

TTATAXIWAY E

A

TAXIWAY FF

TAXIWAY E

TAXIWAY

TAXIWAY M

RUNWAY 13/31

TAXIW

AY H

TAXIW

AY H

TAXIWAY A

TAXIWAY EE

TAXIWAY E

TA

XI

W

AY

G

TAXIWAY D

TAXIWAY F

TAXIWAY C

TAXIWAY J

TA

XI

W

AY

G

TAXIWA

TAXIWAY F

TA

XI

W

AY

K

TAXIWAY D

TA

XIW

AY E

E

TAXIWAY B

R U

N W

AY

/3

416506

21222121

592959292

216216

590505

5947594759465946

1401401128

11341134

10488

135135

110707

56045604

10471

56055605

1131132

40574

285285

114646

33073307

59355

808808

625406

156156

10501

66426642

59225

40044004

70427042

10431043

32243224

473473

0387038

70437043

590590

101102

58245824

11031103

93029302

10933

21102110

59145914

70057005

61089

024024

2462462462 624246

40794079

10177

503503

838838837837

625096250925

0234023

62528

25262523

990990

10881

1091111111

40054005

37743774

57045

57305730

0251025

10861086

13213

62501X62501X

077077

10491049

10711071

10891089

8043804

1127127

10721072

811811

21377

66046604

11051105

339339339

40014

22121

11311131

43774

592592

10511

10971097

20204

10271027

16916

9649649

504504

33030

6251262512

90039003

6251662516

38103810

38073807

819819

10321032

113114

232123

6252562525

13610

241241

21432143

11241124

93039

87487

40024002

3 11

10291029

32023202

66662

3123127

12111

35921592359163591

0461046

0541054

99999

1081085

467467

625462543

37123712

08108484

295295

10626262106

98988

5353535

328328 2

069069

6606603

60266026

210210132101

409400

03805

212821288

8488488

71086

6624624

03802

1121132

279279

5390253902

50414

55300

66640

56601

930930G

948-E

4045404

44410044044

9911-E1-E

948-W8

6101961019

911-W911-W911-W911-

033001

35913591

233233

62501

65672

93493

930S930S

4360943609

42116

90190

10661

1331133

091099

58285828

59245924

70417041

10231023

994994

31253

37743774

70377037

1139113

62517625

40784078

10361036

33083308

1192119

10581058

9075907

40284028

403240322

93069

963963

817817

40684068

10255

38063806

38083808

38093809

2516251

60066666

10351035

6252662526

21402

37153715

62527

58115811

6250362503

47247

309304

32063206

6251362513

2861289

6254262542

62501OK666625062

1128911289

10341034

9999955

106910

3 14

021020

16250011

159301593015930

1590815908159081

1590415904

159041

590859081159081

1590815908

1590415904

590459041590411

159081

6250225025

41046046

11111

50250

04006

62514625162

250250

6106101

0666620

21122112

71089

44044

33315

43120

4115741157

44045045

09359999

44361

622522

41163163

1593015930

15930

10781078

182411824

50005000

84300

438848

84368436

43184

38433

33509

21342134

04002

35921359213591635916

335591

131131

55 625

98798

81108

041104

279279

O1O

62513

AYAY

21392139

11351

81888

9602296022

54555555

266661226

16211

441104

13610

SS

81581558585588

StSt.tArnold SSArnold StSldArnold St.Stt.tArnold SS

Ea st

Dr

D E tDD

SE 74th StSE 74th St

SE 59th St.SE 59th St.

Ai r D ep ot iiir De p AAi riir po t

Patrol Rd.Rd.dRd

StStSt af fD r

St af fD r.

St af ta St af f D r.

St af f D r.

Reserve Rd.

Re

R

ReReeserve Rd eeserve R e ve RdRd

Reserv ReRese Re rv Reserve Rd ve RdRdRd

Reserve Rd eRese ReRese ReRe

Rd.

RRdRd.

Rd

5th veAve5th Ave55 h55 h5 AveA

"A " A ve

A veve

. e.

A

A vv

A Av e A ve .. e.

A Avv

M un iti on s R d.

M un iti on s R d.

W ar e ar e W ar eh ou se

Rd a

W ar eh ou se W ar e ar eh ou se ar eh a ho us e hheheh ou se ou e RRRdRddddd e

RR

e Rd

. d ee ehe W ar eh ou se

Rd W a dd

"B "A ve Av e

BB

vv

B A vAv B ve ve "A

"B "B

Av e

Av e

AAv B

e. e Av e

7th St.7th St7th St7

"H

"AH"

A H"

A H

A

"HHH

Av e.

Av e.55

A H

A H

AA

HHH

H"H

"A ve

H" Av e H

Av e

MMM

cN ar ne y Av e cN ar ne y Av e yyyy cN ar ne y

Av e.

MM

cN ar ne y Av e e

A rn ee Av e Av y A ey A e

M cNN

M c

Mitchell AveMMMitMiMMM tchell Avell Ah Avetchell AveAveitttMitchell Aveitchell AveAvet

Al er tR d tt R d.

R Al er Al Al er tR d tR

Al er er tR er t Al

Rd oo k

A CCo o CCo ok A ve

Co ok

A v

CCo o

CCo ok

A ve

W es tD r

W tD

W es t D r.

W es t D r.

t D r t

"E "A"A

"E "A ve E

Av e

"E "A ve "A e E

Av e

E Av e

Extender Dr.t d DrDDDDrDDDrder

SSentry Rde d.SentSe try yy RRd.Rd.RRRd.Sentry RdS ntry RdSenntryn dSentry RdSentrySenntryn d

4th St.S34th StS34th St4th St.S34th St g r.ggTwin Dr.gggTwining DrnTwining DTwining DrTwining Drnnng gg DrngggTwining DrTwining Dr

5th Ave.5th Ave555th Ave

JoJJoJJo ne s JJoJJo ne s n sesnn

J ne ssesne Jo ne s

Jo ne s JJJJo ne s

Globemaster Dr.obemaster DremGlobemaster DrobemGlobemaster Dr.emGlobeGlobeGlobeobee

To w er RdR

To w er R

d. RRdR TTTo w er

To w er RdRRd

R

Vanaman Rd.Rd.Vanaman RdVanaman RdVanaman Rd.Vanaman Rd

In du st ria lB lv d.

In du st ria l B lv d.

So ut h St

SSS

th

St th

S t ut h

St

So uut h t.t.

SoSSo ut h St

.t

11st St.1st StSSt11 ttst1ss1st StStst SSststssss

Do ol itt le

A ve

Do ol itt le Av e.

Rd.

Rd

Picnic RdRd Picnic RdRRd.

Rd Picnic R

Ja m es D r.

J

D m

Ja m e J m

JJ

s D rDDDs DD rD mm Ja m es

D r

Ja m es D r.

es

J D m s Ds DD rD m ee m

W olfe Dr.

W olfe Dr.

Ai r D ep ot

De po t pp

Ai rD ep ot

De ppppp

Ai r D ep ot

Ai r D ep ot

"D " A ve

D A ve

"D "A ve

Ave.

Raw lings Ave.

ter Rd.Rd Perimeter Rd PeriPPerimeter Rd e

Rapcon Rd.

con Rdd.d

Rapcon Rd.

Rapcon Rd.

Rdd

Reserve RdRd eserve RdRd

Reser Rese Reserve RdRd

"L "A ve Av e

LL

A vAvv

e. eve

. e. ve L

AA

L

AAv ee

Av e

L veee

L

AA

L" Av e "L

"A

Hercules /Mercury Rd.rcury Rd.Hercules /Mercury RdddH lHHH l /M RdHercules /Mercury Rdrcury Rdules /Mercury RddddHerceHee

"F "A veve F

A ve ve

F

e. e

F Avv e "F

"A veve

F A

1st St.1st S1st St.1st St.St1st St1st St

Br ow n D

B ow n w n w n

BB

owoow n o nn

D n

Br o

B o

BBr ow n Dr w n w n

Br ow n Dr

B n

Dr Br ow B o n

Dr n r ow n o nn Dr n r

Br o

B o

BBBr ow n Dr w

Br n r.

P nd

R PPo nd Rd

. d PoPo nd R

d. d.

Po

Rd Po nd R

PoPo nd

Rdd Po

Rd

O ld

A ir

De po t De

O ld

Ai rDD ep ot ep ot e t

AireyyreyyeyyreAirr yyAirey Dr.rereAAirey Dr.A rey DDDeyyAiAi rDrDDDyyAAAA DrDy Dy DyyeyreyAirA rAAAirey DrDy reeyyre DAir y DDy Airey Dr.A rey D .DrDy Dy DeyreyAiA rAA otors Dr otors Dr

General Motors Dr

MoMotototors Dr otors Dr

General Motors Dr

Mototttoto yBradley Dr.rad r.B dl DB dl DBradley Dr.rad r.Bradley Drrrrrrr.rr.

Entrance Road "C"E R ddE t d "C""C"dEntrance Road "C""C"Entrance Roade Road C ntrance RoaoaoEntrance Road "A"oaRoad "A"RoRance RRoaEntrEntrance Roadoaorance Road "A"Rorance RRoa AAAAAAAAAA

"C "A ve

CC

A vAv

C Av e.

CC"

Av e.

C

AA

ve "C

""A "C

"C

" AA

"C

" A ve ot Rd.lot Rlotarden Plot PPlotGarGarGaGGarden Pen ot Rot RPlot PlotGaGGa Hilltop Rd opp Rd.

Hilltop Rd.

HHilltop HHilltop Rd Hilltop Rd.

op Hilltop H p Rd

Do rm ito ry

R d.

m y

Rd y Rd

. d Do rm ito ry Rdd

Dormitory Rd o ry Rdy Rdyyyyy rmitor itoit15 o DoDDorDororrrDDDoDDoDDormitory Rd rm d.

Dormitory Rd D ro o Dormitory Rd

"M

" AA

"M

" AAA

vevevevevv "M

" AAAAAAA

ChennenChhhee nnnanaheehCC nnnnChennaultenCChChennault Dr.r.lt DanCh aua tlt DDultlltltaahhChCCC r.rrrDDDDDDDDulaheehCC nnaan DrrDt Dt D

Chennanaen uCh anaaheehCC nnnnChennault ultaunneCh DuulauheehCC enne naan DDt Dt D

M itchell Ave.

MM

itchell Ave.

M

VandVVVandenburg St.Stg St.t.S451345134VandenburVVVandVandenburg StStVandennburg St.tS451513VandenburgVandVandenburg St.StVVVV rgrg

Eng Engine

Test Dr.

Engine Test Dr.

Te Engine

Test Dr

AAveAADDDDDDoDDoolittle AveD ADoolittle Aveettolio ilittltllDoo Aveoooo leetitttiDoolittle AveDoolittle Atttt AveAololiDDDoDo e e ADoolittle AveettolioDoo Aveooo leetittti

W hi te D r.

W e r.

h e

W h

Dr

WW

hh W h W h ee

W hi te Dr

W ee h W e

DD

hhi te

Dr t

DDD

itth

W hh

DDrD W hi te

Dr

W e r.

h e W h Dr

W hi te D

WW

ete h DrD hi tt h

WWWW

h W h eee

DDrD

3rd Ave3 d A3rd Ave.3rd Ave3rd Ave

"D "D i

"DD

"D i

""D"DD

"D i

DD" "D

D riv e "D

"D riv e

D

Ba ll

Pa rk

R d.

BaBa ll

Pa rk

Rd aBa ll Pa rk Rd

B ll

P k

Rd al l P ar k Rd

BaBa ll Pa rk RdRd

JooJJJoint STARS DrAJ i t STARSi t STARS DDoo RS Dr.RS Dr.RSRAAAAint STAint STAAA SS Droint STARSint STARS

Ai r D ep ot

B lv d p

Ai r D epp Ai rD ep ot Bl vd AAi rD ep

A

TurbiTTurbine DrTTTT DTurbine DrDTurbine Dr.ur urbine DrDTurbine Dr..ne DrTuTT e DrTurbine Drr.Dr.neTuTuTurbinu bi

Central Plant Dr.Pl Dr.Central Plant Dral Plant DrCentral Plant Dr.Dr.Central Plant DrPla

6th St.6th St.6th St6 St6th S6 tSt6th 6th AAA

Falco n Dr.

FF

DDDDr

FFFFalco n Dr

FFF lclclco nnn DrDr

FFFFFFFFFF llllclclclllll nnnnnn DD

FalFaallclclclcFFF nnnn DDrDr lcolco n Dn Drr llcco n Dr.

onn DDrD aa ccll

DDDDn Dn D cocoonnn Dr.Dr

Falco n Dr.

F lco non DDrD alcFalFallclclclc DDDn Dn D cocoonononon Dr.Dr.

FFalco n Dr

Faalclclco nonon DrDrDr

FalFaallclclcFFFF onnon DrDrDr colco nn Dn Drr

BlaBllBlaccc BBlBllBlBlBl ckc bcccclaclacall c bbbbbbb Blackb ird Dr rdirrd ckkbb

BlBla d

Blackb ird

D birdirdird kbkbkb laBlala kbkbkkb iirrd aa kkkkkkk rdrdrdrrrdrd

Blalaa kb irdbird kbackckalalalala irdirdirdrd Drd kbkbkbkb BlBl

Dr.DrDr

Blackb irdrdrr ckbbb BlaBlaBlacc d Dr

BlBlBlBlBlBl rrr ckbckkbb d Dr rdrr cccclac

BlaBlaclBl c birrb rrbbbbbb Blackb ird D irdrd ckbkbkblaBla kb irbird kbackcklalalaBlala rdirdrdirdrd Drd kbkbkb BlBl d looppo o d ooo ll popop loooppo oooo dd and loop l oo d

W eyland looo

W e

W ey a l nd

WW

ndnd eyl eylaa d W e W eeyl eyl

W ey

W eeylala

W e

WWW

d loopo o dd loooppo oooo ddd W eyland looo W e W y l nd

WW

Propulsion Dr.Propulsion DrPropulsion Dr.Propulsion Dr.

ThThThThThThThunderbolt D r.

ThThThunderbolt D r.

Munitions Rd. Ext.Munitions Rd. Ext.

odding Rdg Rdg Rg RCodding RdCC RddCoddiC d.

Codding RdC RdCodding Rdng dC

Starlifter DStarlifter DStarlifter Dr.Dr9002Starlifter DDStarlifter Dfter D

Chidlaw Ct.C Cd tawhidd ww CCttt.tt.tw Cwhiddlad a CCCtChidlaw CtCh d wdldh d Cw Ctwhidh dCC lawd whidlaw Ct.Cd Ctaw t.tw Cwhidddlad a CCCtChidlaw CtCh d ww Ctwhidh dCC lawd wC

Co rs ai r D r.

CCo rs ai r D r

CC

i

D CCo rs ai r D r.

C

Ra pt

Raa pa t apapaaaRaRaaaaaaaaa papp t app to

RaRaRa pt or C

Ra or

C to

Ra pt o Ra pt oor

Ct

CCt

CCCt .t.Ct .tt.t.Ct

CttCtr CC

Ra pt or C

Ra papapp to rr r C apapapap t app t r Cr C oor RaRaRa pt oo

Ra pt oo

NNNNi gh t H aw k ghh

HHa gg tH aHHa hhht ht waaaaaHH ggggigg ht

H aw k C ghhh HHaaa ww k w k

CCC

g k gggh tH aw k hhh

HHHa ww kkk HHHaaa ww hhhht hhhhhh

HHHHHH

gh

H ht h

HHaHaaaa www k w k ww k w h Ct

Ct Cttt CCCt CCCttt ig ht

H aw k hhh

HHHa ww ht Ha w k ghh HHaaa w k w HHa k C k

CCC

k k ww ghh H k ht h

HHaHa

CC

HaHHa hhht h awwa g w k w kkk wwaww h aaaaa CCCCCt Ct CC

HH

gggiggggg

Ph an to m

D hha nt om hha nt om

D h r.r.

Ph an to m D r h nnini nkl nnn nnn nkli n i Franklin F n ni a nnn klin kkkklin k nnnn Franklin n nin annnnann nnn nkli n i F nklin nk

F n

F nklin k n nnnn n

Fra

Po w er ho us e

Dr

Dr us e

DD

ouu e

DD

e DDDr Dr

Sk ym as te r kky m as te r kky m as te r k

Dr

Dr

Sk ym as te r D k

SpSSSSSSpSSpaatz CSpaatz Ct.CCt.CtCtCa ztSpSSSpSpaatz CCCCpaatzt aw r a ee w ree aLaaLa w re nc e e

Laa nc e La w ree aww ree aw e

LaaLa w rer aw en ce

M u

M uu

MMMM

u

M u

MMMMMMM

nunuunuuun d unn de ll ddnd e nnddd el lllllll nd el l ununnununnuunnnnn dnd el l ell ll nd el lllll

Dr.DDrrrrs DDDs DNaNaNNNNNNaaNabors DN bNaaborsNNNaborsa s Ds DDDDDss DborboooboooobbNaNNaNNNaaNabbabNaaNaabors D er Dr.

r ntruderr truder der Intrud ntruder Dr Dr.

M cNicklee

M ickle ckklk

Nicckle k

M cN

MMMMMMMMMM

ee

Nickle N ck Nic N ckle k

M cNic

MMM

Ni

MMM

c c

MMM

cNc

MMMM

cN

MMMMMMMM

ill er Dr leel M ill eer

DDDDDDDDDrr ill er

D r.

MMMMMMMM

lle r D r erl D le Dr leee rr D llelell r DD rr er D r M ill eather Dr.

eaeeather eathe aeaeaee Tail Fe

D eather D eaeath eat ee r D r.r.en Dnenen Dnen DDDDDdedld nnnooldddeedeeenenennnnHoHoHHooHHHHHoldeedeeHoldHHooHoldeeedeeldHHoolo dddeeeeeeHHHHolHollde

Ai re y re y Ai re y re y

AA

erere

Ai rere

AiAAiAi rirAi r

Ai ririrAiAAAAAA eyey

A eyyeyey

Ci r.

yeyy Ci rCirrCiCiCC r.rr ey

Ci r.

yey C

.r.

eyeyeyyeyy

Ciriry C mith Ct.

h CtCtCt mit Smi SmSSSSmSmSmSmSmSmSSSmSmSS t.t.

n

Ct.

n tCt Raven v nn vennnnnnn R veve Rave Rave av R vennn n Ct.

CtCt.

n

CC

nnnn C n .t.

Mitchell Ave hel

Mitchell Ave hel heheell Ave hel

MiMi e

Mitchell Ave chelelel

MM

Air D e otpp Air D ep ot ep o

151571571157ep ot ep Ai

Ai r D ep ot

De po ttttt Ai r D ep ot Ai r

VanamaamVanaa ammaVanaman Rd.maV RdRdnVanaman RdamVanaman Rdma Rd

1st St.11st St1 t StStS1st St.11st St.11st1 t tt

1st St.1st St.

AvAvh5th A uurbiur

L" A

"L "A ve

RdRd dd

DoDoo

0541054

"C " A ve

AA

AveA

DD 6th SS6th SS

MM

cNNcN arar

Entrr

21282128 r r r ot ep ot e

AAAA

DDTurbine Dr.Turbine Dr.ur

St af fD r.

St af f D r.

Road C l rr

333055

TuTu

EnEn erve eerveerve eerve n Rd n

RR

SttSt

43184 bine

NN

RRR

StSt

77877rt Al err t

Al er

Al Al e mmSmSmmm

DrDDrDDDrDDDDDDDrDDD de l dede l d

RdR c RRc RR

A st111

So uu

So utu

MM

c

M c

M ryryorororyo

AA

M illill

Dr

FrFr nndnn orsorsorsboboo ooooololooolooereere d.dd.

ff D ff D ff Dr ff Dr

A

CCCC

dld

1104110411 iv e riv e i trance Rntr t SttSStttt Stt St

S e eeeee t.t.

Av e

AvA"A ve aw

TTT

33033 dddd.d

Rap Ra tD r tD e e

.d.

mVanaamma ve ve ve

Avv e

E

R

CCC

W es t D r.

Do rm ito ry

Rd ry

Rd Do rm ito ry Rd

Do rm

De

885 SSSS

Starlifter DDStarlifter DDStarlifter DD

S DDSSS DDS

In

ReReRReReReRe

Garden Prden PPGa h St ou th

AA ..ARS DrAAiiint STAA

DrDrDDDDDDDStarlifter Dfter D

FeFeeFeFeFeFeFeFe

DDDD

3rd Ave.3rd Ave

B" Av e B"

Av e

935999995 9359999999

1st1st

504144 e Dre Drersorsoorsoaababbabbaa

RRR

1st St.St1st St.St1

581555

D it

Do rm ito ry

Rddd r

4 7

RdRd

RdRd p Rd p Rd.

00000000

HiHi pp

Rd.

p

Rd.

p

Rd.

ules /Mercury Rdddcules /Mercury Rddd po tB lv d pp ot

Air

Dr mit iAAiAi rD ep Ai hThThThThThThThThTh

CCCCCCCCCC hhhhh kkkkk

DDrrrr

Ai rD eppppp ppppp

SE 59th StSE 59th St

XIWAY

SE 74th St SS

DD

ThTh

CC PP

ooint STAAAARS DrARS Drint STAA

Propulsion Dr

Extender DrrDPPo Extendd r Dr.Drr rr DD Inn

JooooJJo

DD

.. DD nnI ow er ho us e D o

DD

o

AAAi r p AAAi rD ep iri t

AAAii AA

Avee Raw lings Ave w li gg

RaR A aw l itchell Ave

Mi e

RRRR

359213592166616 3592135921

Dooo r oDo rmooDoo itto ryry m ito ry rmrmrmm ito ry ititii rmm i rmm i rry rmitrrmrroooororrrrrr

15930

AveAAveA5th55th Ah veAve55tth Ave.5 5th AveAA

Ea st

DrD

Ea st

DD

E

Dr

120000

W es t D r

W ess t D r

W es t D r

W es t D r.

W es t D r.

ntrance tranceEn Road CentSe ry Rd.te y RdR

St.St.11ssst Sst S1s1s11

"A "A ve

DD" ""

St af fD r

W ar eh ou se Rd ou s

Rd ar e d e R ehe

RRR

7th St.7

A ld SSSttttSStttll S yy dd dddd ddddR dde Roade dd

62625050

11622501

62 125011

22626255222

22222

TTTTTTT

TAXIWAY B

TAT

TT

EEEEE

Y Y an an

Patrol Rd.Rd.Rd

Ai rD ep ot

De p

Ai rD ep ot

Ai r D ep ot

De po ttt r D ep ot

Ai r

Ai rD ep AAi rD ep

A po tB lv d Ai r D ep ott r D epp r De p o pppp Ai rD ep ot AiAi ep otppo t

Dep o ep o

111511115 nene l R

MICRO FOUNDRY EXPANSION

BUILDING 9001

CONTRACT NO. W912BV22R0015

GENERAL NOTES:

1. BRAND NAMES: REFERENCE TO SPECIFIC BRAND NAMES OR COMPANIES IS FOR THE PURPOSE OF ESTABLISHING

MINIMUM QUALITY STANDARDS, IDENTIFICATION AND GUIDANCE AND IS NOT INTENDED TO LIMIT SELECTION OF OTHER MANUFACTURERS THAT ARE EQUAL OR EXCEED THE SPECIFIED ITEMS IN TERMS OF PHYSICAL PROPERTIES, INCLUDING, COLOR RANGE, FINISH, DURABILITY, APPEARANCE, PERFORMANCE CHARACTERISTICS, AND OTHER FACTORS. OTHER PRODUCTS, MATERIALS, COLORS AND SYSTEMS, MAY BE SUBMITTED FOR

EVALUATION AND APPROVAL/DISAPPROVAL BY THE CONTRACTING OFFICER.

2. THIS SET OF CONSTRUCTION DOCUMENTS SHALL BE CONSIDERED AS A WHOLE IN THAT THE GENERAL CONTRACTOR AND ALL THE SUB-CONTRACTORS ARE RESPONSIBLE FOR THE INFORMATION PRESENTED ON ALL

SHEETS ON THE SET OF DRAWINGS AND ALL SECTIONS OF THE SPECIFICATIONS.

3. THE CONTRACTOR IS RESPONSIBLE FOR ERECTING ALL CONSTRUCTION FENCING AND BARRICADES AS REQUIRED TO PROTECT CONSTRUCTION MATERIAL AND TO PREVENT ANY UNAUTHORIZED PERSONNEL FROM

ENTERING THE CONSTRUCTION SITE.

4. ANY DAMAGE TO THE EXISTING GROUNDS OR FACILITIES CAUSED BY CONSTRUCTION TRAFFIC OR ANY CONSTRUCTION OPERATION SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR TO MATCH OR EXCEED

EXISTING CONDITIONS AT NO ADDITIONAL COST TO THE GOVERNMENT.

5. ALL WORK NOTED & LOCATED IN THESE DOCS SHALL BE UNDERSTOOD BY THE CONTRACTOR TO REQUIRE ALL

NEW LABOR & MATERIALS UNLESS SPECIFICALLY NOTED TO BE "EXISTING" OR "BY OTHERS".

G001

TI

TL

E

SH

EE

T, A

RE

A

MA

P

DR

AW

IN

G

IN

DE

X

GE

NE

RA

L N

OT

ES

L.

H

AM

PT

O N

R . C

AR

TE

R

R . C

AR

TE

R

Globemaster DrGlobemaster Dr.bGlobe

Po w er ho us e

Dr D us e D ou e

D e

DDDr Dr PPo w er ho us e

DD

o

DD

o

Patrol RRPatrol R

DDDDDrr emaster Dr.bGlobeG

Po w us e ou e

Po w er ho e Po w er ho us e o

DDDDDD

Globemaster Dre

Patrol RRRoPatr

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y :

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y :

AN

SI

D

IS

SU

E D

AT

E:

TA

SK

O R

D

ER

N O

C O

N

TR

AC

T

N O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

TU

LS

A D

IS

TR

IC

T

E . 8

1S T

ST

R

EE

T

TU

LS

A O

K, 3 7

W

2B V2

2C

SHEET ID

R . C

AR

TE

R

M

AR

C

H

TI

N

K

ER

A

FB

, O K

LA

H

O M

A M

IC

R

O F

O U

N D

R Y

EX

PA

N

SI

O N

B U

IL

D

IN

G

C

O N

TR

A

C T

N O

W

2B

V2 2C

SHEET OF 8

A

M001

ME

CH

AN

IC

AL

LE

GE

ND

O F

SY

MB

OL

S

AB

BR

EV

IA

TI

ON

S, S

CH

ED

UL

ES

L.

H

AM

PT

O N

R . C

AR

TE

R

R . C

AR

TE

R

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y :

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y :

AN

SI

D

IS

SU

E D

AT

E:

TA

SK

O R

D

ER

N O

C O

N

TR

AC

T

N O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

TU

LS

A D

IS

TR

IC

T

E . 8

1S T

ST

R

EE

T

TU

LS

A O

K, 3 7

W

2B V2

2C

SHEET ID

R . C

AR

TE

R

M

AR

C

H

TI

N

K

ER

A

FB

, O K

LA

H

O M

A M

IC

R

O F

O U

N D

R Y

EX

PA

N

SI

O N

B U

IL

D

IN

G

C

O N

TR

A

C T

N O

W

2B

V2 2C

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y :

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y :

AN

SI

D

IS

SU

E D

AT

E:

TA

SK

O R

D

ER

N O

C O

N

TR

AC

T

N O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

TU

LS

A D

IS

TR

IC

T

E . 8

1S T

ST

R

EE

T

TU

LS

A O

K, 3 7

W

2B V2

2C

SHEET ID

R . C

AR

TE

R

M

AR

C

H

TI

N

K

ER

A

FB

, O K

LA

H

O M

A M

IC

R

O F

O U

N D

R Y

EX

PA

N

SI

O N

B U

IL

D

IN

G

C

O N

TR

A

C T

N O

W

2B

V2 2C

SHEET OF 8

A

M100

MI

CR

O

FO

UN

DR

Y

FL

OO

R

PL

AN

S

L.

H

AM

PT

O N

R . C

AR

TE

R

R . C

AR

TE

R

M110

MI

CR

O

FO

UN

DR

Y

RO

OF

P

LA

NS

L.

H

AM

PT

O N

R . C

AR

TE

R

R . C

AR

TE

R

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y :

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y :

AN

SI

D

IS

SU

E D

AT

E:

TA

SK

O R

D

ER

N O

C O

N

TR

AC

T

N O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

TU

LS

A D

IS

TR

IC

T

E . 8

1S T

ST

R

EE

T

TU

LS

A O

K, 3 7

W

2B V2

2C

SHEET ID

R . C

AR

TE

R

M

AR

C

H

TI

N

K

ER

A

FB

, O K

LA

H

O M

A M

IC

R

O F

O U

N D

R Y

EX

PA

N

SI

O N

B U

IL

D

IN

G

C

O N

TR

A

C T

N O

W

2B

V2 2C

M200

CR

O

FO

UN

DR

Y

SE

CT

IO

N

L.

H

AM

PT

O N

R . C

AR

TE

R

R . C

AR

TE

R

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y :

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y :

AN

SI

D

IS

SU

E D

AT

E:

TA

SK

O R

D

ER

N O

C O

N

TR

AC

T

N O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

TU

LS

A D

IS

TR

IC

T

E . 8

1S T

ST

R

EE

T

TU

LS

A O

K, 3 7

W

2B V2

2C

SHEET ID

R . C

AR

TE

R

M

AR

C

H

TI

N

K

ER

A

FB

, O K

LA

H

O M

A M

IC

R

O F

O U

N D

R Y

EX

PA

N

SI

O N

B U

IL

D

IN

G

C

O N

TR

A

C T

N O

W

2B

V2 2C

E110

CR

OF

OU

ND

RY

EL

EC

TR

IC

AL

R

OO

F

PL

AN

S

M . R

IC

H

AR

D

S

M . S

AC

KE

TT

W . W

R I G

H T

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y :

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y :

AN

SI

D

IS

SU

E D

AT

E:

TA

SK

O R

D

ER

N O

C O

N

TR

AC

T

N O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

TU

LS

A D

IS

TR

IC

T

E . 8

1S T

ST

R

EE

T

TU

LS

A O

K, 3 7

W

2B V2

2C

SHEET ID

R . C

AR

TE

R

M

AR

C

H

TI

N

K

ER

A

FB

, O K

LA

H

O M

A M

IC

R

O F

O U

N D

R Y

EX

PA

N

SI

O N

B U

IL

D

IN

G

C

O N

TR

A

C T

N O

W

2B

V2 2C

E301

CR

OF

OU

ND

RY

FI

RE

A

LA

RM

P

LA

N

M D

R

W H

W

W H

W

FI

RS

T

FL

OO

R

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y :

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y :

AN

SI

D

IS

SU

E D

AT

E:

TA

SK

O R

D

ER

N O

C O

N

TR

AC

T

N O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

TU

LS

A D

IS

TR

IC

T

E . 8

1S T

ST

R

EE

T

TU

LS

A O

K, 3 7

W

2B V2

2C

SHEET ID

R . C

AR

TE

R

M

AR

C

H

TI

N

K

ER

A

FB

, O K

LA

H

O M

A M

IC

R

O F

O U

N D

R Y

EX

PA

N

SI

O N

B U

IL

D

IN

G

C

O N

TR

A

C T

N O

W

2B

V2 2C

SCALE: 1/8"=1'-0"

ROOF FRAMING PLAN1

S100

SCALE: NONE

AND MECHANICAL UNIT SUPPORT

TYP. ROOF OPENING FRAME

S100 SCALE: NONE

STEEL JOISTS W/ POINT LOADS

BRACING DETAIL FOR

S100 SCALE: 1 1/2"=1'-0"

AT RTU FRAMES

FIELD - BOLT OPTION

S100

US Army Corps of Engineers ®

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y :

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

TA

SK

O R

D

ER

N O

C O

N

TR

AC

T

N O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D E S

C R

IP

TI

O N

TU

LS

A D

IS

TR

IC

T

E . 8

1S T

ST

R

EE

T

TU

LS

A O

K, W

2B V2

2C

SHEET ID

R . C

AR

TE

R

M

AR

C

H

TI

N

K

ER

A

FB

, O K

LA

H

O M

A M

IC

R

O F

O U

N D

R Y

EX

PA

N

SI

O N

B U

IL

D

IN

G

C

O N

TR

A

C T

N O

W

2B

V2 2C

SHEET 8 OF 8

525 Central Park Drive, Suite 202 Oklahoma City, OK 73105

405.528.4596 | kfcengr.com

Kirkpatrick Forest Curtis PC Structural Engineering engineeringg gg gg gg gg gg gg gg g

OK CA #3888, EXP. 06/30/23

KFCKFC

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

S100

MI

CR

O

FO

UN

DR

Y

PL

AN

S

AN

D

SE

CT

IO

NS

B.

C

AM

PB

EL

L

R . F

O R

ES

T

R . F

O R

ES

T

SHEET:

DRAWN BY:

CHECKED BY:

JOB #:

PROJECT #:

DE

SC

RI

PT

IO

N

CA

D

DA

TE

MA

RK

SYSTEM:

CH

K

ISSUE DATE:

" x

A rch

E 1 S ize

IS

SU

E

LO

G:

Re vis ion s s ho wn w ith s ym bo l

SYSTEM SEQUENCE OF OPERATIONS

PROJECT DIRECTORY

APPLICABLE CODES & STANDARDS

ABBREVIATIONS LEGEND

GENERAL NOTES

LEGENDSDRAWING INDEX

DEVICE TAG LEGEND

SCOPE OF WORK

FIRE ALARM SYSTEM

W912BV22R0015

TAFB B9001 MICRO FOUNDRY EXPANSION

FA: = FACP (NON-NETWORK)

#: = NODE NUMBER

T#: = TRANSPONDER NUMBER

#:T# = NODE:TRANSPONDER NUMBER

N#: = NAC EXTENDER NUMBER

DEVICE NUMBER

BRANCH / ISOLATED LOOP DESIGNATOR:

CIRCUIT DESIGNATOR

PANEL DESIGNATOR

1:T2:A2-1(E1:1)

A# = IDNAC1 CIRCUIT NUMBER

D# = DOOR HOLDER CIRCUIT NUMBER

F# = FIRE PHONE CIRCUIT

H# = AUDIBLE (HORN) CIRCUIT NUMBER

M# = IDNET LOOP NUMBER

P# = POWER CIRCUIT NUMBER

S# = SPEAKER CIRCUIT NUMBER

V# = VISUAL CIRCUIT NUMBER

Z# = ZONE NUMBER

(L#) = IDNET ISOLATED LOOP NUMBER

(#) = IDNAC BRANCH NUMBER

(E#:#) = EPR2 NUMBER:BRANCH NUMBER

1. IDNAC = ADDRESSABLE NOTIFICATION CIRCUIT

2. EPR = ENHANCED POWER REPEATER

1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS IS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON

THE RECORD DRAWINGS.

2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR DEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO AS NOT TO IMPAIR THE

CONSTRUCTION SCHEDULE.

3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZED CHANGE.

ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS.

4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION.

5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A BRANCH CIRCUIT

BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL

UNIT.

6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO JOHNSON CONTROLS NO

LATER THAN 7 DAYS AFTER FINAL TEST.

7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER.

8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL REPRESENTATIVE.

9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECT FROM

DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER.

10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIES ANY TIME

THAT WORK IS NOT ACTIVELY BEING PERFORMED.

11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND NON-POWER

LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND APPLICABLE ELECTRICAL CODES. REFER TO 'APPLICABLE CODES & STANDARDS' FOR SPECIFIC CODE REFERENCES.

12. ALL WIRING SHALL BE INSTALLED ACCORDING TO APPLICABLE ELECTRICAL CODES.

13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIRE ALARM WIRES IN

ACCORDANCE WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE.

14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP.

15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL

RUNS IN SHAFTS SHALL BE TYPE FPLR.

16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET LOCATIONS.

17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOORS SHALL BE INSTALLED IN ACCORDANCE APPLICABLE

ELECTRICAL CODES, WHERE APPLICABLE.

18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS.

19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE.

20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT.

21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING.

22. MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS.

23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY; HOWEVER, ANY EXISTING CONDUIT

WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. JOHNSON CONTROLS MAKES NO STATEMENTS WRITTEN OR

VERBAL AS TO THE CONDITION OF EXISTING CONDUITS.

Site

TINKER AIR FORCE BASE B9001

OKLAHOMA CITY, OK

Johnson Controls District - 442

2835 SOUTH UTAH AVENUE

OKLAHOMA CITY, OK 73108

PHONE: 405-246-1000

FAX: 405-682-6169

SERVICE: 405-246-1000

MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW DUCT DETECTOR, SHUT DOWN RELAY AND REMOTE TEST STATION FOR RTU-18V-1 AND

CONNECT TO EXISTING NODE 18 TPR1 IN SAND MOLD PRINTER LAB AS SHOWN ON DRAWINGS.

ALL NEW WIRING TO BE CLASS B.

THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK

CONNECTIONS, OR TESTING.

OCCUPANCY TYPE(S):

B BUSINESS GROUP BUILDING IS FULLY SPRINKLERED

JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECK

WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS.

S

AOM

FIRE ALARM SYMBOL LEGEND

QTY SYMBOL DESCRIPTION BRAND MODEL BACKBOX WIRE

TYPE

INITIATING DEVICES

1 ADDRESSABLE DUCT SMOKE DETECTOR SIMPLEX 4098-9755 MOUNTS TO DUCTWORK

M

SAMPLING TUBE, 97" SIMPLEX 4098-9858

MODULES AND RELAYS

1 RELAY IAM SIMPLEX 4090-9002 4" SQ. 2-1/8" D W/ DBL. GANG COVER

M R

TRIM PLATE FOR SURFACE MOUNTING SIMPLEX 4090-9802

MISCELLANEOUS DEVICES

1 REMOTE TEST STATION SIMPLEX 2098-9806 SINGLE GANG 2"D K

JUNCTION BOX BY OTHERS BY OTHERSJB

4" SQ. 2-1/8"D

ACCEPTABLE

CABLE TYPES

FIRE ALARM WIRE LEGEND

FP

LR

FP

LP

TH

HN

TF

FN

OU

TD

OO

R

C.

I.CIRCUIT DESCRIPTION CONSTRUCTION GAUGE CIRCUIT PROPERTIES

K REMOTE TEST SWITCH/LED (2) 2 COND. SOLID 14 AWG X X

M IDNET UTP SOLID 16 AWG 0.60μF MAX TOTAL LINE

CAPACITANCE X X

P POWER 2 COND. SOLID 14 AWG X X X X

R RELAY 2 COND. SOLID 14 AWG X X X X

CONDUIT SIZE MAX CONDUCTOR AREA CONDUIT SIZE MAX CONDUCTOR AREA

1/2" 0.122 SQ. INCH* 1-1/4" 0.598 SQ INCH*

3/4" 0.213 SQ INCH* 1-1/2" 0.814 SQ INCH*

1" 0.346 SQ INCH* 2" 1.342 SQ INCH*

* 40% CONDUIT FILL PER N.E.C.

UTP = UNSHIELDED TWISTED PAIR

ITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING AND INSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS. RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE

UPON REQUEST.

AC = ABOVE CEILING

AFF = ABOVE FINISHED FLOOR

AHJ = AUTHORITY HAVING JURISDICTION

ALM = ALARM

ANN = ANNUNCIATOR

BMS = BUILDING MANAGEMENT SYSTEM

C = CEILING MOUNTED

CD = CANDELA RATING

DET = DETECTOR

DGP = DATA GATHERING PANEL

E = EXISTING TO REMAIN

EOL = END OF LINE

EPO = EMERGENCY POWER OFF

ER = ELEVATOR RECALL

FAA = FIRE ALARM ANNUNCIATOR

FACP = FIRE ALARM CONTROL PANEL

FATC = FIRE ALARM TERMINAL CABINET

FBO = FURNISHED BY OTHERS

FCC = FIRE COMMAND CENTER

FSD = FIRE SMOKE DAMPER

FTR = FIRE ALARM TRANSPONDER

H = HIGH HUMIDITY

HT = HEIGHT

HVAC = HEATING VENTILATION & AIR CONDITIONING

IMS = INFORMATION MANAGEMENT SYSTEM

MAX = MAXIMUM

MIN = MINIMUM

N/A = NOT APPLICABLE

NAC = NOTIFICATION APPLIANCE CIRCUIT

NDU = NETWORK DISPLAY UNIT

NEC = NATIONAL ELECTRIC CODE

NFPA = NATIONAL FIRE PROTECTION ASSOCIATION

NIC = NOT IN CONTRACT

NPU = NETWORK PROCESSING UNIT

NTS = NOT TO SCALE

PAP = PRE-ACTION PANEL

RC = EXISTING TO REMOVE AND COVER

RD = EXISTING DEVICE TO BE RELOCATED

RL = RELOCATED DEVICE

RR = REMOVE EXISTING & REPLACE WITH NEW

SCC = STATUS COMMAND CENTER

SLC = SIGNALING LINE CIRCUIT

SMK = SMOKE

SUPV = SUPERVISORY

TAC = TRUEALERT ADDRESSABLE CONTROLLER

TOS = TOP OF SHAFT

TRBL = TROUBLE

TS = TAMPER SWITCH

TYP = TYPICAL

UON = UNLESS OTHERWISE NOTED

VCC = VOICE COMMAND CENTER

VT = VALVE TAMPER

W = WATTAGE

W/ = WITH

W/O = WITHOUT

WF = WATERFLOW

WG = WIRE GUARD

WP = WEATHERPROOF

XP = EXPLOSION PROOF

JOHNSON CONTROLS CONTACTS

LA

ST

P

RI

NT

ED

LA

ST

S

AV

ED

B Y:

FI

LE

P

AT

H:

C:

\U se rs\ jsu llia n\O ne Dr ive

Jo hn so n C on tro ls\

TA

FB

\B

M icr o F ou nd ry

4\F ire

\F A-

1.d wg 2/1

4/2

4 4 :11

:30 P

M

JC

OT

TE

K

442:650243444

BDB

KLC

6/19/23

FIRE ALARM SYSTEM

TI

NK

ER

A

IR

F

OR

CE

B

AS

E B9

OK

LA

HO

MA

C

IT

Y, O

K

S

OU

TH

U

TA

H

AV

EN

UE

OK

LA

HO

MA

C

IT

Y, O

K

PH

ON

E:

5-

6-

SE

RV

IC

E:

5-

6-

FA

X:

-6

-6

DI

ST

RI

CT

FA-001

COVER SHEET

JOHNSON CONTROLS © 2023

TA

FB

B

M

IC

RO

F

OU

ND

RY

E

XP

AN

SI

ON

W

2B

V2 2R

© Johnson Controls 2023. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited.

IMPORTANT NOTICE TO USER: This information may not be sold or transferred to any third party, used on other projects or additions to the project for which it was prepared, or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use or reuse of altered files by the user or any third party and such use will be a user's sole risk. User shall, to the fullest extent permitted by law, defend, indemnify, and hold Johnson Controls harmless from any and all claims for loss, damage or injury arising directly or indirectly from any such unauthorized use.

National Electric Code (NFPA 70), 2017 Edition

National Fire Alarm and Signaling Code (NFPA 72), 2019 Edition

Standard for Installation of Air Conditioning and Ventilating Systems (NFPA 90A), 2018 Edition

UFC 3-600-01: Fire Protection Engineering for Facilities, With Change 6, 6 May 2021

UFC 4-021-01: Design and O&M: Mass Notification Systems, 1 January 2010

Engineering Construction Bulletin (ECB) 2018-17: New Requirements for Visual Notification for Mass Notification Systems. 14 May 2020

Sales Representative

BILLY DEWAYNE BENSON

BILLY.BENSON@JCI.COM

PHONE: 405-618-7572

Project Manager

CHANTEL HICKS

CHANTEL.HICKS@JCI.COM

PHONE: 405-568-1456

Drawings Prepared By

KEVIN COTTER

KEVIN.COTTER@JCI.COM

PHONE: 314-292-0128

Drawings Reviewed By

BILLY DEWAYNE BENSON

BILLY.BENSON@JCI.COM

PHONE: 405-618-7572

NICET IV: #83227

Sheet List Table Sheet Number Sheet Title

General Information (FA-000 Series)

FA-001 COVER SHEET

Floorplans (FA-100 Series)

FA-101 DEVICE PLACEMENT PLAN

Riser Diagrams (FA-200 Series)

FA-201 RISER DIAGRAM

Calculations (FA-600 Series)

FA-601 CALCULATIONS, SCHEDULES AND WIRING TYPICALS

YYYYY

2221201918

XXXXX

2221201918

WWWWW

2221201918

VVVVV

2221201918

UUUUU

2221201918

SAND MOLD

PRINTER LAB

18:

T1:V

12-

18:

T1:V

13-

18:

T1:V

12-

18:

T1:V

13-

18:

T1:V

12-

18:

T1:V

13-

18:

T1:V

12-

18:

T1:V

13-

JB

JB

JB

JB

JB

JB

JB

JB

JBJB

110CD

NAC19-3-2

NA

TEXT

TEXT F

18:T1:M1-4

F 18:T1:M1-5

C .5W

SC

18:T1:A3-6(1) 18:T1:S6-6

.5W

SC

18:T1:A3-4(1) 18:T1:S6-4

.5W

C

18:T1:A3-5(1)

18:T1:S6-5

.5W

A,M,S,2V

A,M,S,2V

F

18:

T1:M

1-1

F

18:

T1:M

1-1

LO

C

TEXT TEXT

S

18:T1:M1-12

A,B,M,P,2V

AOM

18:T1:M1-13

18:T1:A3-11(1)

18:T1:A3-10(1)

S LS

18:S3-1 3.8W

R

B,P,T

2M,4V

A,M,S,2V

A,M,S,2V

A,M,S,2V2M,4V

A,B,M,P,S,T,2V

M

M,K

S18:T1:M1-36

SUPPLY AOM

18:T1:M1-37

M

B,S,T,X

A,M,S,2V

A,K,M,S,2V

2M,K

2A

4V 2M,4V

2M,2S,4V A,M,S,2V

SHADED AREA EXISTING & NIC

V

W

U

1918 20 21 22

SHEET:

DRAWN BY:

CHECKED BY:

JOB #:

PROJECT #:

DE

SC

RI

PT

IO

N

CA

D

DA

TE

MA

RK

SYSTEM:

CH

K

ISSUE DATE:

" x

A rch

E 1 S ize

IS

SU

E

LO

G:

Re vis ion s s ho wn w ith s ym bo l

SCALE: IN FEET1/8" = 1'-0"

4' 8' 16'

N

SCALE:1/8" = 1'-0"

DEVICE PLACEMENT PLAN

LA

ST

P

RI

NT

ED

LA

ST

S

AV

ED

B Y:

FI

LE

P

AT

H:

C:

\U se rs\ jsu llia n\O ne Dr ive

Jo hn so n C on tro ls\

TA

FB

\B

M icr o F ou nd ry

4\F ire

\F A-

1.d wg 2/1

4/2

4 4 :12

:54 P

M

JS

UL

LIA

N

442:650243444

BDB

KLC

6/19/23

FIRE ALARM SYSTEM

TI

NK

ER

A

IR

F

OR

CE

B

AS

E B9

OK

LA

HO

MA

C

IT

Y, O

K

S

OU

TH

U

TA

H

AV

EN

UE

OK

LA

HO

MA

C

IT

Y, O

K

PH

6-

SE

RV

IC

E:

5-

6-

-6

-6

DI

ST

RI

CT

FA-101

DEVICE PLACEMENT PLAN

JOHNSON CONTROLS © 2023

TA

FB

B

M

IC

RO

F

OU

ND

RY

E

XP

AN

SI

ON

W

2B

V2 2R

© Johnson Controls 2023. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited.

GENERAL NOTES:

1. THE DEVICE ADDRESSES INDICATED ON THESE DRAWINGS ARE AN

ALPHANUMERIC DESCRIPTION OF WHICH CIRCUIT THE DEVICE IS LOCATED ON.

DEVICES MAY BE ASSIGNED A DIFFERENT NUMBER WITHIN THE PANEL PROGRAM.

CONSULT WITH A JOHNSON CONTROLS TECHNICIAN BEFORE APPLYING A

PHYSICAL LABEL TO ANY DEVICES.

KEYNOTES:

INSTALL DUCT DETECTOR RELAY WITHIN 3'-0" OF CONTROLLING EQUIPMENT.

VERIFY LOCATION IN FIELD AND INCLUDE ON RECORD DRAWINGS.

INSTALL REMOTE TEST STATION IN ACCESSIBLE AREA AND CONFIRM LOCATION

WITH OWNER. VERIFY LOCATION OF REMOTE TEST STATION IN FIELD AND

INCLUDE ON RECORD DRAWINGS.

CONNECT MICRO FOUNDRY DUCT DETECTOR AND RELAY TO NODE 18

TRANSPONDER 1 THROUGH Y21 SAND MOLD PRINTER LAB. IDNET/24VDC TO

EITHER RUN TO MICRO FOUNDRY AND BACK OR CONNECT TO LAST END OF LINE

IDNET/24VDC DEVICE AT Y21 SAND MOLD PRINTER LAB. USE OF SPLICES,

T-TAPS, WIRE NUTS, CRIMPED CONNECTORS IS PROHIBITED. JCI FIRE ALARM

TECHNICIAN TO VERIFY LOCATION OF CONNECTION IN FIELD.

SCALE:N.T.S.

KEYPLAN

AREA OF WORK

APPROXIMATE LOCATION

OF NODE 18 FACU

APPROXIMITE LOCATION OF

NODE 18 TRANSPONDER 1

S

S

S

S

K

P

M

M

M

V

V

V

V

A

V

V

A

K

B9001 B9001

IDNet - 18:T1:M1 F

18:

T1:M

1-2

F

18:

T1:M

1-3

F

18:

T1:M

1-4

B,Sd

B,Sd

LOC

F

18:

T1:M

1-5

S

18:

T1:M

1-1

BATTERY

CABINET

SS

P

120 VOLT AC

4100ES

LOCATED NEAR GRID

LINES EE 20

NODE #18

FACU-MNS

B,Sd

B,Sd

EXISTING

EXISTING

T,XT,X

4100ES

LOCATED NEAR GRID

LINES BB 23

NODE #18

TRANSPONDER #1

SS

P

120 VOLT AC

F

18:

T1:M

1-1

F

18:

T1:M

1-1

S

18:

T1:M

1-1

AOM

18:

T1:M

1-1

TO

A

HU

_1

R

AIM

18:

T1:M

1-1

WF

Z

6.8K

AIM

18:

T1:M

1-1

VS

Z

6.8K

F

18:

T1:M

1-1

LOC

T,XT,X

18:

T1:V

20-

18:

T1:V

19-

18:

T1:V

20-

18:

T1:V

19-

18:

T1:V

20-

18:

T1:V

19-

NAC - 18:T1:V19

NAC - 18:T1:V20

10K

NAC - 18:T1:V20

10K

NAC - 18:T1:V19

18:

T1:V

20-

18:

T1:V

19-

18:

T1:V

20-

18:

T1:V

19-

18:

T1:V

20-

18:

T1:V

19-

TEXTTEXTTEXTTEXTTEXTTEXT

IDNet - 18:T1:M1(LOOP2)

AIM

18:

T1:M

1-2

AIM

18:

T1:M

1-2

AOM

18:

T1:M

1-2

TO

F

IR

E

DA

MP

ER

CO

NT

RO

L

R

F

18:

T1:M

1-2

AOM

18:

T1:M

1-2

AC

CE

SS

CO

NT

RO

L

IN

TE

RF

AC

E

R

F

18:

T1:M

1-2

F

18:

T1:M

1-2

AIM

18:

T1:M

1-2

WF

Z

6.8K

AIM

18:

T1:M

1-2

VS

Z

6.8K

F

18:

T1:M

1-3

AOM

18:

T1:M

1-3

TO

F

IR

E

DA

MP

ER

CO

NT

RO

L

R

NAC - 18:T1:A4(1)

C

18:

T1:A

4-1 (1)

18:

T1:S

8-1

1W S C

18:

T1:A

4-2 (1)

18:

T1:S

8-2

1W C

18:

T1:A

4-3 (1)

18:

T1:S

8-3

1W C

18:

T1:A

4-4 (1)

18:

T1:S

8-4

1W C

18:

T1:A

4-5 (1)

18:

T1:S

8-5

1W C

18:

T1:A

4-6 (1)

18:

T1:S

8-6

1W S C

18:

T1:A

4-7 (1)

18:

T1:S

8-7

1W S C

18:

T1:A

4-8 (1)

18:

T1:S

8-8

2W C

18:

T1:A

4-9 (1)

18:

T1:S

8-9

2W S C

18:

T1:A

4-1 0(1

18:

T1:S

8-1

2W S C

18:

T1:A

4-1 1(1

18:

T1:S

8-1

2W S C

18:

T1:A

4-1 2(1

18:

T1:S

8-1

2W S C

18:

T1:A

4-1 3(1

18:

T1:S 8-1

2W S C

18:

T1:A

4-1 4(1

18:

T1:S 8-1

2W

S C

18:

T1:A

4-1 5(1

18:

T1:S

8-1

2W C

18:

T1:A

4-1 6(1

18:

T1:S

8-1

2W S C

18:

T1:A

4-1 7(1

18:

T1:S 8-1

2W C

18:

T1:A

4-1 8(1

18:

T1:S

8-1

2W

NAC - 18:T1:V14

M

18:

T1:V

14-

190EX

NAC - 18:T1:V21

M

18:

T1:V

21-

190EX

Speak - 18:T1:S7

S EX

18:

T1:S

7-1

7.5W

Speak - 18:T1:S8

10K

NAC - 18:T1:S7

10K

NAC - 18:T1:V21

10K

NAC - 18:T1:V14

LOCA T,XT,X

Z

F EX

Z

F EX

6.8K 6.8K

NAC - 18:T1:A9(1)

Speak - 18:T1:S5

TEXTTEXTTEXT TEXT

TEXTTEXTTEXT

18:

T1:V

12-

18:

T1:V

13-

18:

T1:V

12-

18:

T1:V

13-

18:

T1:V

12-

18:

T1:V

13-

S C

18:

T1:A

3-1 (1)

18:

T1:S

6-1 .5W

C

18:

T1:A

3-2 (1)

18:

T1:S

6-2

.5W S C

18:

T1:A

3-3 (1)

18:

T1:S

6-3

.5W S C

18:

T1:A

3-4 (1)

18:

T1:S

6-4

.5W C

18:

T1:A

3-5 (1)

18:

T1:S

6-5

.5W S C

18:

T1:A

3-6 (1)

18:

T1:S

6-6

.5W C

18:

T1:A

3-7 (1)

18:

T1:S

6-7

.5W

NAC - 18:T1:V12

NAC - 18:T1:V13

10K

NAC - 18:T1:V12

10K

NAC - 18:T1:V13

18:

T1:V

12-

18:

T1:V

13-

18:

T1:V

12-

18:

T1:V

13-

18:

T1:V

12-

18:

T1:V

13-

18:

T1:V

12-

18:

T1:V

13-

X22 PROJECT

Y21 PROJECT

X22 PROJECT

18:

T1:A

3-1 0(1

18:

T1:A

3-1 0(1

18:

T1:A

3-1 0(1

Speak - 18:S3

Y21 PROJECT

Y21 PROJECT

S LS

18:

S3-1

3.8W

S LS

18:

S3-2

3.8W 10K

Speaker - 18:S3

X22 PROJECT

Y21 PROJECT

S

18:

T1:M

1-2

AOM

18:

T1:M

1-3

AH

U

SH

UT

DO

W N

R

B,P

B,P

B,P

S EX

18:

T1:S

7-2

7.5W

IDNet - 18:T1:M1(LOOP3) F

18:

T1:M

1-4

F

18:

T1:M

1-4

F

18:

T1:M

1-4

F

18:

T1:M

1-4

F

18:

T1:M

1-4

AIM

18:

T1:M

1-4

VS

Z

6.8K

AIM

18:

T1:M

1-4

WF

Z

6.8K

S

18:

T1:M

1-4

NAC - 18:T1:A16(1)15

18:

T1:A

16- 1(1

C

18:

T1:A

16- 2(1

18:

T1:S

9-1

.5W C

18:

T1:A

16- 3(1

18:

T1:S

9-2

.5W C

18:

T1:A

16- 4(1

18:

T1:S

9-3

.5W C

18:

T1:A

16- 5(1

18:

T1:S

9-4

.5W C

18:

T1:A

16- 6(1

18:

T1:S

9-5

.5W C

18:

T1:A

16- 7(1

18:

T1:S

9-6

.5W

18:

T1:A

16- 8(1

C

18:

T1:A

16- 9(1

18:

T1:S

9-7

.5W C

18:

T1:A

16- 10(

1)

18:

T1:S

9-8

.5W C

18:

T1:A

16- 11(

1)

18:

T1:S

9-9

.5W S C

18:

T1:A

16- 12(

1)

18:

T1:S

9-1

.5W S C

18:

T1:A

16- 13(

1)

18:

T1:S

9-1

.5W

C

18:

T1:A

16- 14(

1)

18:

T1:S

9-1

.5W C

18:

T1:A

16- 15(

1)

18:

T1:S

9-1

.5W S C

18:

T1:A

16- 16(

1) 18:

T1:S 9-1

.5W C

18:

T1:A

16- 17(

1)

18:

T1:S

9-1

.5W

18:

T1:A

16- 18(

1)

C

18:

T1:A

16- 19(

1)

18:

T1:S

9-1

.5W

18:

T1:A

16- 20(

1)

NAC - 18:T1:A17(1)

C

18:

T1:A

17- 1(1

18:

T1:S

9-1

.5W C

18:

T1:A

17- 2(1

18:

T1:S

9-1

.5W C

18:

T1:A

17- 3(1

18:

T1:S

9-1

.5W C

18:

T1:A

17- 4(1

18:

T1:S

9-2

.5W C

18:

T1:A

17- 5(1

18:

T1:S

9-2

.5W C

18:

T1:A

17- 6(1

18:

T1:S

9-2

.5W C

18:

T1:A

17- 7(1

18:

T1:S

9-2

.5W C

18:

T1:A

17- 8(1

18:

T1:S

9-2

.5W C

18:

T1:A

17- 9(1

18:

T1:S

9-2

.5W15

18:

T1:A

17- 10(

1) 18:

T1:S 9-2

.5W C

18:

T1:A

17- 11(

1)

18:

T1:S

9-2

.5W C

18:

T1:A

17- 12(

1)

18:

T1:S

9-2

.5W

18:

T1:A

17- 13(

1)

18:

T1:V

20-

18:

T1:V

19-

18:

T1:V

20-

18:

T1:V

19-

18:

T1:V

20-

18:

T1:V

19-

18:

T1:V

20-

18:

T1:V

19-

18:

T1:V

20-

18:

T1:V

19-

TEXTTEXTTEXTTEXTTEXT

LOC

B,P,T,X

REACT LAB III PROJECT

REACT LAB II PROJECT

REACT LAB III PROJECT

REACT LAB III PROJECT

REACT LAB II PROJECT

REACT LAB II PROJECT

AOM

18:

T1:M

1-4

R R

R

TO

F

AN

A

S

A

S

K

AOM

18:

T1:M

1-4

R R

R

AC

CE

SS

CO

NT

RO

L

IN

TE

RF

AC

E

S

18:

T1:M

1-3

AOM

18:

T1:M

1-3

R

RTU-18V-1

MICRO FOUNDRY

24VDC

P

P

F

18:

T1:M

1-3

F

18:

T1:M

1-3

C

18:

T1:A

17- 14(

1)

18:

T1:S

9-2

.5W C

18:

T1:A

17- 15(

1)

18:

T1:S

9-3

.5W

SHEET:

DRAWN BY:

CHECKED BY:

JOB #:

PROJECT #:

DE

SC

RI

PT

IO

N

CA

D

DA

TE

MA

RK

SYSTEM:

CH

K

ISSUE DATE:

" x

A rch

E 1 S ize

IS

SU

E

LO

G:

Re vis ion s s ho wn w ith s ym bo l

LA

ST

P

RI

NT

ED

LA

ST

S

AV

ED

B Y:

FI

LE

P

AT

H:

C:

\U se rs\ jsu llia n\O ne Dr ive

Jo hn so n C on tro ls\

TA

FB

\B

M icr o F ou nd ry

4\F ire

\F A-

1.d wg 2/1

4/2

4 4 :11

:33 P

M

JS

UL

LIA

N

442:650243444

BDB

KLC

6/19/23

FIRE ALARM SYSTEM

TI

NK

ER

A

IR

F

OR

CE

B

AS

E B9

OK

LA

HO

MA

C

IT

Y, O

K

S

OU

TH

U

TA

H

AV

EN

UE

OK

LA

HO

MA

C

IT

Y, O

K

PH

6-

SE

RV

IC

E:

5-

6-

-6

-6

DI

ST

RI

CT

FA-201

RISER DIAGRAM

JOHNSON CONTROLS © 2024

TA

FB

B

M

IC

RO

F

OU

ND

RY

E

XP

AN

SI

ON

W

2B

V2 2R

© Johnson Controls 2024. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited.

RISER NOTES:

1. RISER IS A DIAGRAMMATICAL REPRESENTATION OF THE

SYSTEM ARCHITECTURE IN BUILDING CROSS SECTION. IT IS

NOT INTENDED TO REPRESENT ACTUAL WIRE RUNS, PANEL

CONFIGURATIONS OR PENETRATIONS. REFER TO FLOOR

PLANS AND PANEL DETAILS FOR CIRCUIT ROUTING AND

CONFIGURATION INFORMATION.

2. ALL WIRING SHALL COMPLY WITH APPLICABLE ELECTRICAL

CODES. REFER TO 'APPLICABLE CODES & STANDARDS' ON

SHEET FA-001 FOR SPECIFIC CODE REFERENCES.

AREA OF WORK

SCALE:N.T.S.

NODE 18 TRANSPONDER 1 RISER DIAGRAM

SHEET:

DRAWN BY:

CHECKED BY:

JOB #:

PROJECT #:

DE

SC

RI

PT

IO

N

CA

D

DA

TE

MA

RK

SYSTEM:

CH

K

ISSUE DATE:

" x

A rch

E 1 S ize

IS

SU

E

LO

G:

Re vis ion s s ho wn w ith s ym bo l

LA

ST

P

RI

NT

ED

LA

ST

S

AV

ED

B Y:

FI

LE

P

AT

H:

C:

\U se rs\ jsu llia n\O ne Dr ive

Jo hn so n C on tro ls\

TA

FB

\B

M icr o F ou nd ry

4\F ire

\F A-

1.d wg 2/1

4/2

4 4 :11

:35 P

M

JS

UL

LIA

N

442:650243444

BDB

KLC

6/19/23

FIRE ALARM SYSTEM

TI

NK

ER

A

IR

F

OR

CE

B

AS

E B9

OK

LA

HO

MA

C

IT

Y, O

K

S

OU

TH

U

TA

H

AV

EN

UE

OK

LA

HO

MA

C

IT

Y, O

K

PH

6-

SE

RV

IC

E:

5-

6-

-6

-6

DI

ST

RI

CT

FA-601

CALCULATIONS,

SCHEDULES AND WIRING

TYPICALS

JOHNSON CONTROLS © 2024

TA

FB

B

M

IC

RO

F

OU

ND

RY

E

XP

AN

SI

ON

W

2B

V2 2R

© Johnson Controls 2024. All rights reserved. Reuse, copying, modification or alteration of the drawings and other information contained herein is strictly prohibited.

PRE-INSTALLATION ROUTINES

INSTALLATION GUIDELINES

FIGURE 1. DUCT HOUSING PLACEMENT - LOCATION OF DAMPERS**

DUCT DETECTOR/SENSOR INSTALLATION

OR

DUCT DETECTORS/SENSORS SHOULD BE INSTALLED IN A LOCATION OF RELATIVELY

NON-TURBULENT AIR FLOW AND WITHIN THE INTENDED OPERATING VELOCITY RANGE OF

300-4000 FEET-PER-MINUTE (91 TO 1220 M/MIN.)

MEASUREMENTS OF AIR FLOW AND EXAMINATION OF ENGINEERING SPECIFICATIONS THAT

DEFINE EXPECTED DUCT AIR VELOCITIES UNDER ALL CONDITIONS IS RECOMMENDED. THIS

IS DONE TO DETERMINE IF A LOCATION IS SUITABLE FOR DUCT DETECTOR/SENSOR

OPERATION. AN ALNOR INSTRUMENT CO. (CHICAGO) MODEL 6000P VELOMETER OR

EQUIVALENT (NOT SUPPLIED) MAY BE USED TO CHECK THE DUCT AIR VELOCITY.

1. LOCATE DUCT HOUSINGS SO THAT DAMPERS DO NOT RESTRICT AIR FLOW AT THE

DETECTOR/SENSOR LOCATION. SEE FIGURE 1.

2. LOCATE AIR DUCT DETECTORS/SENSORS ON THE RETURN OR SUPPLY DUCT OF THE

EQUIPMENT'S AIR HANDLING SYSTEM. HOWEVER, DETECTORS/SENSORS SHOULD NOT BE

INSTALLED IN THE RETURN AIR DAMPER BRANCH. SEE FIGURE 1.

3. LOCATE AIR DUCT DETECTORS/SENSORS ON BRANCH LINES IF CLOSE IDENTIFICATION OF

THE ALARM SOURCE IS REQUIRED.

4. LOCATE AIR DUCT DETECTORS/SENSORS ON THE DOWNSTREAM SIDE OF FILTERS TO SENSE

FIRE IN FILTERS. HOWEVER, SHOULD THE FILTERS BLOCK, SUFFICIENT AIR FLOW MAY NOT BE

AVAILABLE FOR PROPER AIR DUCT DETECTOR/SENSOR OPERATION. SEE FIGURE 1.

5. WHENEVER POSSIBLE, LOCATE AIR DUCT DETECTORS/SENSORS WHERE THEY CAN BE

CONVENIENTLY OBSERVED AND READILY SERVICED.

6. LOCATE THE AIR DUCT DETECTORS/SENSORS IN RETURN AIR DUCTS AHEAD OF MIXING

AREAS.

7. DO NOT LOCATE AIR DUCT DETECTORS/SENSORS NEXT TO OUTSIDE AIR INLETS UNLESS YOU

WANT TO MONITOR SMOKE ENTRY TO THE HANDLING SYSTEM FROM AN ADJACENT AREA.

8. LOCATE AIR DUCT DETECTORS/SENSORS UPSTREAM OF AIR HUMIDIFIERS AND COOLING

COILS.

9. DO NOT INSTALL THE DUCT DETECTOR HOUSING OR DUCT TUBES IN LOCATIONS THAT

EXCEED THE LISTED TEMPERATURE RATINGS FOR THE DEVICE.

10. DO NOT MOUNT THE DUCT HOUSING ON BOTTOM OF DUCT.

1. TAPE THE TEMPLATE (SUPPLIED) ON THE DUCT SURFACE. DO NOT POSITION THE

TEMPLATE WITH EDGES ANGLED WITH RESPECT TO AIR FLOW DIRECTION. SEE FIGURE 2.

2. DRILL TWO 1 1/4 INCH (31.75 MM) HOLES (MARKED "A") AS LOCATED BY THE TEMPLATE.

REMOVE TEMPLATE AFTER HOLES HAVE BEEN DRILLED.

3. IF THE DUCT IS MORE THAN 3 FEET (0.9 M) WIDE, THEN PUNCH A 1-INCH (25.4 MM) HOLE IN

THE DUCT WALL DIRECTLY OPPOSITE THE UPSTREAM 1-1/4 INCH (31.75 MM) HOLE. SEE

FIGURE 3. THIS HOLE IS USED TO SUPPORT THE INLET TUBE.

4. INLET TUBES SHOULD BE SELECTED AND CUT TO LENGTH AS SPECIFIED IN TABLE 1.

AFTER TRIMMING THE INLET TUBE OPPOSITE THE SLOT, TAP RUBBER PLUG (SUPPLIED)

INTO THE TRIMMED END. SEE FIGURE 3.

INLET TUBE SELECTION

OVERALL DUCT WIDTH TUBE

REQUIRED TUBE TYPE SUGGESTED TOTAL LENGTH

12" (30cm) 4098-9854 13" (33.02cm) 1/2" (1.27cm) LONGER THAN

DUCT WIDTH

13" (33.02cm) TO 23" (58cm) 4098-9855 24" (60.96cm) 1/2" (1.27cm) LONGER THAN

DUCT WIDTH

24" (60cm) TO 46" (116cm) 4098-9856 49" (125.46cm) 2" (5.8cm) LONGER THAN

DUCT WIDTH

46" (116cm) TO 71" (180cm) 4098-9857 73" (185cm) 2" (5.8cm) LONGER THAN

DUCT WIDTH

71" (180cm) TO 95" (240cm) 4098-9858 97" (245cm) 2" (5.8CM) LONGER THAN

DUCT WIDTH

SUPPLY

AIR

EXHAUST

* REFER TO INSTALLATION INSTRUCTION DOCUMENT 574-776 FOR MORE

DETAILED INFORMATION.

** WHEN PROVIDING CONTROL FOR A SMOKE DAMPER INSTALLED WITHIN AN AIR

TRANSFER OPENING IN A WALL, THE DUCT DETECTOR SHALL BE INSTALLED

WITHIN 5 FEET HORIZONTALLY OF THE DAMPER.

NEVER MOUNT AT AN ANGLE

WITH RESPECT TO AIR FLOW

AIR FLOW

DIRECTION

ORAIR FLOW

DIRECTIONOR AIR FLOW

DIRECTION

VERTICAL DUCTS

OR AIR FLOW

DIRECTION

FIGURE 2. TEMPLATE POSITIONING

EXHAUST DAMPER

FRESH AIR INTAKE

DO NOT LOCATE

DETECTOR/SENSOR HERE FILTER BANK DETECTOR/SENSOR

RETURN AIR DAMPER

DO NOT LOCATE

DETECTOR/SENSOR HERE

RETURN AIR

DETECTOR/SENSOR

INLET TUBE

RETAINER

BRACKET

TAB

SEE NOTE 1

NOTES:

1. THE TAB ON THE INLET TUBE

RETAINER BRACKET INDICATES THE

INLET HOLE SIDE IF THE PIPE.

2. THE INLET TUBE MUST BE INSTALLED

THROUGH THE HOLE IN THE HOUSING

CORNER NEXT TO THE SMOKE

PORT/AIR FLOW TEST HOLES.

EXHAUST TUBE

RUBBER PLUGINLET TUBE

INLET TUBE HOLES FACE

UPSTREAM OF AIRFLOW

SEE NOTE 2

TABLE 1. INLET TUBE SELECTION

OR

AIR FLOW

DIRECTION

INSERT RUBBER PLUG

THIS END OF INLET TUBE

TUBE SUPPORT HOLE

ONLY FOR DUCTS MORE

THAN 3 FEET WIDE

INLET TUBE

HOLES FACE

UPSTREAM

OF AIR FLOW

EXHAUST TUBE

DO NOT INSERT

RUBBER PLUG INLET TUBE HOLES FACE

UPSTREAM OF AIR FLOW

EXHAUST TUBE

DO NOT INSERT RUBBER PLUG

CUT EXHAUST

TUBE TO 1/2 OF

DUCT WIDTH WHEN

WIDTH IS LESS

THAN 24"

TOP VIEW

NOTE:

AIRFLOW CAN BE IN EITHER DIRECTION. MAKE SURE THE INLET

TUBE HOLES FACE UPSTREAM OF AIR FLOW

FOR DUCT WIDTHS 36"-95" FOR DUCT WIDTHS 12"-36"

FIGURE 3. INLET TUBE ORIENTATION

FIGURE 4. INLET TUBE INSTALLATION

DUCT SMOKE DETECTOR INSTALLATION GUIDE

HORIZONTAL DUCTS

UNDER 13" HIGH

HORIZONTAL DUCTS

OVER 13" HIGH

0=OFF1=ON

192 208

144 160 176

204 220

156 172

150 166 182 198 214

1286432

7 86

42 3 5

ADDRESS SHOWN ABOVE IS 120

ON

1OFF

96 112 128

48 64 80

108 124 140

60 76 92

54 70 86 102 118 134

0 16 32

12 28 44

6 22 38

DIP SWITCHES 5 THRU 8

DO NOT USE ADDRESS 0 FOR AN IDNET ADDRESS

NOTE:

THE 4098-9771, -9794, -9795, -9798 SOUNDER BASES HAVE A 9-POSITION DIP SWITCH. THE FIRST EIGHT DIP SWITCHES SET THE SOUNDER BASE ADDRESS. DIP SWITCH POSITION 9 IS SET TO OFF OR ON DEPENDING UPON THE SOUNDER BASE POWER SOURCE. WHEN THE SOUNDER BASE IS CONNECTED TO A 24 VDC POWER SOURCE, DIP SWITCH POSITION 9 IS SET TO “OFF” AND THE 24 VDC POWER IS SUPERVISED BY THE SOUNDER BASE. WHEN THE SOUNDER BASE IS POWERED BY THE PANEL’S NOTIFICATION APPLIANCE CIRCUIT (NAC), DIP SWITCH POSITION 9 IS SET TO “ON” AND THE POWER IS SUPERVISED BY THE NAC AND NOT THE SOUNDER BASE. THE 4098-9770 AND -9797 BASES HAVE THE SAME LAYOUT, BUT DOESN’T OFFER

SOUNDER FUNCTIONALITY. THEY USE AN 8-WAY DIP SWITCH ONLY.

SEE

NOTE

DIP

SWITCHES

1 THRU 4

DIP SWITCH SETTINGS - INITIATING

SIMPLEX IDNet

CONNECT TO REMOTE ALARM

LED OUTPUT OF

APPROPRIATE INITIATING

DEVICES

CONNECT TO REMOTE TEST

SWITCH INPUT ON

APPROPRIATE INITIATING

DEVICES

FLUSH MOUNTING

STANDARD SINGLE GANG

ELECTRICAL BOX 2" X 3", 2"

MINIMUM DEPTH. SUPPLIED BY

ELECTRICAL CONTRACTOR.

1. MAINTAIN CORRECT POLARITY ON TERMINAL

CONNECTIONS.

2. ALWAYS CUT CONDUCTORS AND SECURE UNDER

TERMINALS. NEVER LOOP WIRES UNDER

TERMINALS.

3. ONE INDICATOR MAY BE INSTALLED PER

DETECTOR.

WIRING NOTES

TEST

RED

BLK

TERMINATION VIEW

REMOTE ALARM INDICATOR / KEY SWITCH

SIMPLEX 2098-9806

SCALE:N.T.S.

NODE 18 TPR1 BATTERY CALCULATION - FIRE

SCALE:N.T.S.

NODE 18 TPR1 BATTERY CALCULATION - MNS

SCALE:N.T.S.

NODE 18 TPR1 IDNET SCHEDULE

IDNET CHANNEL 18:T1:M1 ADDRESSES IN USE: 38 (15.2%) | SPARE ADDRESSES: 212 (84.8%) SWITCH SETTINGS Address Device Type Point Type Location Description 1 2 3 4 5 6 7 8

18:T1:M1-1 PHOTO SMOKE ABOBE TPR1 18:M1-1 X ON

18:T1:M1-2 ADRPUL PULL X22 BREAK ROOM 18:M1-2 X ON

18:T1:M1-3 ADRPUL PULL X22 BREAK ROOM 18:M1-3 X X ON

18:T1:M1-4 ADRPUL PULL X22 BREAK ROOM 18:M1-4 X ON

18:T1:M1-5 ADRPUL PULL X22 BREAK ROOM 18:M1-5 X X ON

18:T1:M1-6 X X ON

18:T1:M1-7 X X X ON

18:T1:M1-8 X ON

18:T1:M1-9 X X ON

18:T1:M1-10 ADRPUL PULL Y21 SAND MOLD PRINTER LAB 18:M1-10 X X ON

18:T1:M1-11 ADRPUL PULL Y21 SAND MOLD PRINTER LAB 18:M1-11 X X X ON

18:T1:M1-12 PHOTO LSDUCT Y21 SAND MOLD PRINTER LAB ROOF 18:M1-12 X X ON

18:T1:M1-13 RIAM RELAY Y21 SAND MOLD PRINTER LAB ROOF 18:M1-13 X X X ON

18:T1:M1-14 IAM WATER Y21 SAND MOLD PRINTER LAB 18:M1-14 X X X ON

18:T1:M1-15 IAM SO Y21 SAND MOLD PRINTER LAB 18:M1-15 X X X X ON

18:T1:M1-16 ADRPUL PULL Y21 SAND MOLD PRINTER LAB 18:M1-16 X ON

18:T1:M1-17 X X ON

18:T1:M1-18 X X ON

18:T1:M1-19 X X X ON

18:T1:M1-20 IAM PULL REACT LAB II TITANIUM LAB 18:M1-20 X X ON

18:T1:M1-21 IAM PULL REACT LAB II ALUMINUM LAB 18:M1-21 X X X ON

18:T1:M1-22 RIAM RELAY REACT LAB II ADMIN 18:M1-22 X X X ON

18:T1:M1-23 ADRPUL PULL REACT LAB II ADMIN 18:M1-23 X X X X ON

18:T1:M1-24 X X ON

18:T1:M1-25 ADRPUL PULL REACT LAB II ADMIN 18:M1-25 X X X ON

18:T1:M1-26 ADRPUL PULL REACT LAB II STEEL LAB 18:M1-26 X X X ON

18:T1:M1-27 IAM WATER REACT LAB II 18:M1-27 X X X X ON

18:T1:M1-28 IAM SO REACT LAB II 18:M1-28 X X X ON

18:T1:M1-29 PHOTO LSDUCT REACT LAB II STEEL LAB 18:M1-29 X X X X ON

18:T1:M1-30 ADRPUL PULL REACT LAB II STEEL LAB 18:M1-30 X X X X ON

18:T1:M1-31 RIAM RELAY REACT LAB II ADMIN 18:M1-31 X X X X X ON

18:T1:M1-32 RIAM RELAY REACT LAB II STEEL LAB 18:M1-32 X ON

18:T1:M1-33 X X ON

18:T1:M1-34 X X ON

18:T1:M1-35 X X X ON

18:T1:M1-36 PHOTO LSDUCT RTU-18V-1 SUPPLY 18:M1-36 X X ON

18:T1:M1-37 RIAM AHUO RTU-18V-1 18:M1-37 X X X ON

18:T1:M1-38 X X X ON

18:T1:M1-39 X X X X ON

18:T1:M1-40 ADRPUL PULL VESTIBULE 101 18:M1-40 X X ON

18:T1:M1-41 ADRPUL PULL HALLWAY 2 117 18:M1-41 X X X ON

18:T1:M1-42 ADRPUL PULL BREAKROOM 1 111 18:M1-42 X X X ON

18:T1:M1-43 ADRPUL PULL HALLWAY 1 109 18:M1-43 X X X X ON

18:T1:M1-44 ADRPUL PULL METROLOGY & MATERIAL TESTING LAB 114 18:M1-44 X X X ON

18:T1:M1-45 IAM SO VERIFY IN FIELD 18:M1-45 X X X X ON

18:T1:M1-46 IAM WATER VERIFY IN FIELD 18:M1-46 X X X X ON

18:T1:M1-47 RPHOTO LSDUCT VERIFY IN FIELD 18:M1-47 X X X X X ON

18:T1:M1-48 RIAM RELAY DUCT DETCTOR REALY 18:M1-48 X X ON

18:T1:M1-49 RIAM RELAY ACCESS CONTROL INTERFACE 18:M1-49 X X X ON

18:T1:M1-50 ADRPUL PULL ELECTRICAL RM 105 18:M1-50 X X X ON

18:T1:M1-51 ADRPUL PULL VIBRATION TESTING 116 18:M1-51 X X X X ON

18:T1:M1-52 X X X ON

18:T1:M1-53 X X X X ON

18:T1:M1-54 X X X X ON

18:T1:M1-55 X X X X X ON

18:T1:M1-56 X X X ON

18:T1:M1-57 X X X X ON

18:T1:M1-58 X X X X ON

18:T1:M1-59 X X X X X ON

18:T1:M1-60 X X X X ON

18:T1:M1-61 X X X X X ON

18:T1:M1-62 X X X X X ON

18:T1:M1-63 X X X X X X ON

18:T1:M1-64 X ON

18:T1:M1-65 X X ON

18:T1:M1-66 X X ON

18:T1:M1-67 X X X ON

18:T1:M1-68 X X ON

18:T1:M1-69 X X X ON

18:T1:M1-70 X X X ON

THRU ON

18:T1:M1-250 X X X X X X ON

NOTE: THE LABELS SHOWN ABOVE WILL BE USED FOR PROGRAMMING PURPOSES.

THE LABELS ARE BASED UPON INFORMATION SHOWN ON THE ARCHITECTURAL DRAWINGS.

ANY CHANGES TO THESE LABELS MUST BE NOTED ON THE SUBMITTAL REVIEW, PRIOR TO PROGRAMMING.

POINTS SHOWN IN ITALIC TEXT REFER TO EXISTING DEVICES.

NODE 18 TPR1 - POST BB-23E 4100es XPDR Standby Total Alarm Total

Module Qty Description Current Standby Current Alarm

Panel Equipment

4100-9600 1 BASIC TRANSPONDER * 0.0870 0.0870 0.0870 0.0870

4100-0622 1 DIGITAL AUDIO RISER MODULE 0.0700 0.0700 0.0700 0.0700

4100-5311 1 ENHANCED POWER SUPPLY, 3 CHANNELS, IDNet, 120V 0.2250 0.2250 0.4900 0.4900

4100-5101 2 EXPANSION PWR SUPPLY (XPS) - 120VAC 60HZ 0.0500 0.1000 0.0500 0.1000

4100-1329 1 DIGITAL 100W AMP,6NAC,120VAC,70V 0.0850 0.0850 3.8000 3.8000

4100-5401 1 ES Power Supply Only 0.0680 0.0680 0.0770 0.0770 4100-5451 1 IDNAC Card 0.1240 0.1240 0.2300 0.2300

4003-9803 3 REMOTE MICROPHONE ON 2 GANG PL 0.0000 0.0000 0.0250 0.0750

4100-1291 1 REMOTE UNIT INTERFACE 0.0850 0.0850 0.0850 0.0850

Panel Totals 0.8440 5.0140

IDNet Addressable Devices (SLC)

4090-9001 8 IDNET SUPERVISED IAM *

Constant current draw of .8mA standby and 1mA alarm per address used.

Devices requiring additional current are accounted for in the section labeled "Miscellaneous Peripheral Devices Requiring Additional System Power".

4090-9002 7 IDNET RELAY IAM *

4098-9714 1 TRUEALARM PHOTO SMOKE SENSOR

4098-9755 3 TRUEALARM DUCT SMOKE SENSOR W/O RELAY OUTPUT *

4098-9756 1 TRUEALARM DUCT SMOKE SENSOR W/ RELAY OUTPUT *

4098-9792 1 TRUEALARM SENSOR BASE *

4099-9006 16 ADDRESSABLE DOUBLE ACTION MANUAL STATION, PUSH *

Miscellaneous Peripheral Devices That Require (Additional) System Power

4098-9843 1 ENCAPSULATED RELAY PAM-SD 0.0000 0.0000 0.0150 0.0150

4098-9756 1 TRUEALARM DUCT SMOKE SENSOR W/ RELAY OUTPUT 0.0030 0.0030 0.0150 0.0150 2098-9806 3 REMOTE TEST STATION W/ LED AND KEY SWITCH 0.0000 0.0000 0.0000 0.0000

YM0163 2 LOCAL OPERATING CONSOLE 0.0780 0.1560 0.0960 0.1920

YM0199 2 LOCAL OPERATING CONSOLE W/ ANNUNICATOR 0.1430 0.2860 0.2360 0.4720

Notification Appliances Setting

D1xB2XH2 2 EXPLOSION PROOF STROBE CEILING MOUNT 0.0000 0.0000 1.2300 2.4600

LEMD-M 18 EMERGENCY MESSAGE DISPLAY 0.0000 0.0000 0.0700 1.2600

IDNac Notification Appliances Setting

49HF-APPLC 17 HI-FI SPEAKER ONLY APPLIANCE CEIL MOUNT 0.0008 0.0136 0.0090 0.1530 49HFV-APPLC 2 TA ADDRESSABLE HF/V APPLIANCE ONLY, CEIL MT 110 0.0008 0.0016 0.1930 0.3860 49HFV-APPLC 15 TA ADDRESSABLE HF/V APPLIANCE ONLY, CEIL MT 15 0.0008 0.0120 0.0590 0.8850 49HFV-APPLC 15 TA ADDRESSABLE HF/V APPLIANCE ONLY, CEIL MT 30 0.0008 0.0120 0.0820 1.2300 49HFV-APPLC 4 TA ADDRESSABLE HF/V APPLIANCE ONLY, CEIL MT 75 0.0008 0.0032 0.1450 0.5800 49HFV-APPLW 3 TA ADDRESSABLE HIGH-FI S/V APPLIANCE ONLY, WALL MT 15 0.0008 0.0024…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .