2026-09-01_Carmel_Emergency_WM_to_WWTP.pdf
PDF 12 MB Posted
- Attached to
- 6" Water Main Gray Rd to Hazel Dell
- Solicitation number
- IFB-2026-015
- Issued by
- Hamilton County, Indiana
About this file
This is a technical drawing set prepared by Wessler Engineering for the City of Carmel Utilities (Board of Public Works) in Hamilton County, Indiana, detailing the design of an emergency water main extension project. The project, identified as 306726-04-001, involves the installation of approximately 2,600 linear feet of 6-inch high-density polyethylene (HDPE) water main running along 96th Street from Gray Road to the Wastewater Treatment Plant near Hazel Dell Parkway. The water main will be constructed using a combination of horizontal directional drilling (approximately 1,747 linear feet) and open cut installation (approximately 65 linear feet), with construction planned to commence following the bid submission deadline of October 7, 2026 at 10:00 a.m. The drawings include plan and profile sheets detailing utility coordination points, existing infrastructure conflicts, erosion control measures, and standard details for pipe transitions, concrete collar installations, and traffic control procedures. The project incorporates multiple mechanical joint (MJ) fittings, reducers, and bends to accommodate connection to existing 12-inch force mains and sewer infrastructure, with careful attention to maintaining 18-inch vertical and 10-foot horizontal clearance between water and sanitary sewer lines.
The design includes comprehensive erosion and sediment control requirements, temporary easement acquisition responsibilities assigned to the contractor at no additional cost to the owner, and coordination requirements with multiple utilities including Citizens Water, Carmel Utilities (Sewer Department), Citizens Gas, CenterPoint Energy, Duke Energy, AT&T, Charter Communications, and Metro Fibernet. The contractor is required to contact the Indiana Underground Plant Protection Service (IUPPS) at least 48 hours in advance of construction, coordinate with all utilities a minimum of two weeks prior to work, and provide written notice to affected customers 24 to 72 hours before any planned utility service interruptions, which shall not exceed four hours. All construction traffic must utilize major roads, with daily dust control measures including soil removal and vacuuming from streets. The project specifications require repair or replacement of all damaged public and private facilities, restoration of existing drainage systems, and compliance with all applicable permits, with the applicable permits to be made available to the contractor by the owner.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 6"_Water_Main_Gray_Rd_to_Hazel_Dell_(Addendum_#1_Revision).pdf | ||
| RIGHT_OF_ENTRY.pdf | ||
| NON_COLLUSION_AFFIDAVIT.pdf | ||
| PAYMENT_BOND.pdf | ||
| SAMPLE_OF_MOU_FOR_E-VERIFY.pdf | ||
| WORK_DIRECTIVE_CHANGE.pdf | ||
| REQUEST_FOR_PROPOSAL_CHANGE.pdf | ||
| Sealed_Bid_Sample_Agreement_-_FEMA.docx | DOCX document | |
| CONTRACT_CHANGE_ORDER.pdf | ||
| CONTRACT_CHANGE_REQUEST.pdf | ||
| Exhibit_D_E-Verify-1.PDF | ||
| FIELD_ORDER.pdf | ||
| MAINTENANCE_BOND.pdf | ||
| PERFORMANCE_BOND.pdf | ||
| SCREENSHOT_INSTRUCTIONS_-_FOR_BIDS.pdf | ||
| MANUFACTURERS_LIST.pdf | ||
| SAMPLE_BID_BOND.docx | DOCX document | |
| SUBCONTRACTORS_LIST.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWINGS PREPARED FOR:
BOARD OF PUBLIC WORKS
LAURA CAMPBELL, PRESIDING OFFICER
JIM BARLOW, MEMBER
ALAN POTASNIK, MEMBER
CARMEL UTILITIES
LANE YOUNG
96TH ST EMERGENCY WM EXTENSION TO WWTP
FOR THE
CITY OF CARMEL UTILITIES
PROJECT NO. 306726-04-001
STATE LOCATION MAP
VICINITY MAP
SCALE: NONE
SCALE: NONE
REGISTERED ENGINEER STATE OF INDIANA NO. 11800823
JOSHUA J. HOOD
SEPTEMBER 2026
HAMILTON
COUNTY
D ra w in g:
X
:\C ar m el
\3
C ar m el
E m er ge nc y
W M to W
W
TP
\D W
G \S he et s\
-G S.
dw g
L ay ou t:
1G
P lo tte d:
9/
/2
3:
:4
L as tS av ed By
: M ic he lle
E
/01
/20
CARMEL, INDIANA
I-465
KE
YS
TO
NE
P
KW
Y
CARMEL, INDIANA
PROJECT LOCATION
6219 South East Street Indianapolis, Indiana 46227
Phone: (317) 788-4551 - Fax: (317) 788-4553
INDIANAPOLIS
www.wesslerengineering.com
I-6
E 96TH ST
GA
RY
R D
G
AR
Y R
O
AD
E 96TH STREET
H
AZ
EL
D
EL
L
PK
W
Y
RI
VE
R
RO
AD
C R
YS
TA
L R
IV
ER
D R
IV
E
R
IV
ER
R
ID
G
E D
R
IV
E
WWTP
CP
CP 1
CP
CP 2
CP
CP 3
CP
CP 4
CP
CP 5
CP
CP 6
TBM
TBM 7
TBM
TBM 8
CONTROL POINTS
POINT
CP 1
CP 2
CP 3
CP 4
CP 5
CP 6
NORTHING
1704459.779
1704401.992
1704404.014
1704403.582
1704400.085
1704386.241
EASTING
212362.882
212064.366
211541.949
211050.682
210490.531
209898.942
ELEVATION
747.03
747.66
744.26
740.65
739.69
740.12
DESCRIPTION
CAPPED REBAR
CAPPED REBAR
CAPPED REBAR
CAPPED REBAR
CAPPED REBAR
CAPPED REBAR
DRAWING INDEX
SHEET
NO. DESCRIPTION
01 TITLE SHEET
LOCATION AND SCOPE OF WORK PLAN
IMAGERY FROM ESRI.
HORIZONTAL AND VERTICAL
CONTROL INFORMATION
NOTES:
1. SURVEY WORK WAS CONDUCTED IN AUGUST 2026.
2. BEARINGS, DISTANCES, AND COORDINATES ARE INDIANA STATE PLANE,
EAST ZONE, NAD83 (2011) EPOCH 2010.00 AND ARE REPORTED IN U.S.
SURVEY FEET.
3. CONTROL POINTS WERE SET USING GPS.
4. ELEVATIONS ARE NAVD88 DATUM AND ARE BASED ON A GPS
OBSERVATIONS OF CONTROL POINT 1
5. A LEVEL LOOP WAS PERFORMED FOR ALL CONTROL POINTS LISTED
HEREON.
BENCHMARK DESCRIPTION:
TBM NO 7 - NORTHWEST BONNET BOLT OF FIRE HYDRANT ON THE
NORTHEAST CORNER OF GRAY RD AND 96TH STREET
ELEV 741.58
TBM NO 8 - CUT "X" IN TOP OF CURB ON THE NORTH SIDE OF THE
ROUNDABOUT AT THE INTERSECTION OF 96TH STREET AND HAZEL DELL
PARKWAY
ELEV 748.16
100 200 400 FT
1" = 200'
LOCATION PLAN AND DRAWING INDEX
MRE
CRY
JJH
Dr aw in g:
X :\C ar m el \3
Ca rm el
E m er ge nc y
W M to W
W
TP
\D W
G \S he et s\
-G S.
dw g
L ay ou t:
1G
P lo tte d:
9/
/2
3:
:4
L as tS av ed By
: M ich el le
E
SHEET NO.NO. DATE REVISION DESCRIPTIONSINITIALS
CHECKED BY
APPROVED BY
ISSUE DATE
PROJECT NUMBER
DRAWN BY 96TH ST EMERGENCY WM EXTENSION TO WWTP
CITY OF CARMEL UTILITIES
CARMEL, INDIANA
/01
/20
SCALE VERIFICATION
BAR IS ONE INCH LONG ON
ORIGINAL DRAWING
SEPTEMBER 2026
306726-04-001
TOTAL SHEETS
WATER MAIN 'LINE A'
SEE SHEETS 04 - 09
02 LOCATION PLAN AND DRAWING INDEX
03 ABBREVIATIONS AND GENERAL NOTES
04 - 09 PLAN AND PROFILE - LINE A
10 - 11 MISCELLANEOUS DETAILS
12 EROSION CONTROL DETAILS
GENERAL NOTES:
1. NOTIFY THE ENGINEER IF ANY CONFLICTING INFORMATION BECOMES APPARENT IN THE CONTRACT
DOCUMENTS AS SOON AS POSSIBLE AND PRIOR TO THE COMMENCEMENT OF ANY WORK IN THE VICINITY OF OR RELATIVE TO THE APPARENT CONFLICT SO THAT CLARIFICATION MAY OCCUR PRIOR TO CONSTRUCTION.
2. ANY ALTERATIONS TO THESE DRAWINGS NOT AUTHORIZED BY WESSLER ENGINEERING AND NOT IN ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS AND RECORDS ON FILE AT WESSLER ENGINEERING SHALL RELIEVE WESSLER ENGINEERING OF ANY RESPONSIBILITY FOR THE ACCURACY OF THE DRAWINGS.
3. USE CAUTION DURING THE EXECUTION OF WORK TO PREVENT DAMAGE TO STATE, COUNTY, MUNICIPAL, AND PRIVATE PROPERTY. REPAIR ALL DAMAGES AS A RESULT OF OPERATIONS, INCLUDING DAMAGE TO DRAINAGE STRUCTURES, FIELD TILES, PUBLIC/PRIVATE ROADS, AND LANDSCAPING (INCLUDING FENCING). REPAIR AND
REPLACE DAMAGED ITEMS AT NO ADDITIONAL COST TO THE OWNER. PERFORM ALL REPAIR AND
REPLACEMENT WORK TO THE SATISFACTION OF THE PERMITTING AGENCY, THE OWNER AND THE ENGINEER.
4. TAKE CARE TO AVOID DAMAGE TO PAVED AREAS WHICH ARE NOT SPECIFICALLY CALLED OUT FOR REPAIR OR REPLACEMENT. REPAIR, OR REPLACE ALL SUCH PAVEMENTS WHICH ARE DAMAGED BY CONSTRUCTION
ACTIVITIES AND CONSTRUCTION TRAFFIC AT NO ADDITIONAL COST TO THE OWNER.
5. OBTAIN ALL TEMPORARY EASEMENTS REQUIRED FOR THE CONSTRUCTION OF THE PROJECT AT NO
ADDITIONAL COST TO THE OWNER.
6. COMPLY WITH ALL APPLICABLE PERMITS AND REGULATIONS. APPLICABLE PERMITS ISSUED TO THE OWNER WILL BE MADE AVAILABLE TO THE CONTRACTOR. CONTACT ALL APPLICABLE PERMITTING AGENCIES WITHIN
THE TIME PERIOD SPECIFIED BY THAT AGENCY PRIOR TO BEGINNING CONSTRUCTION.
7. ALL PRIVATE WELL LOCATIONS SHOWN ON THE DRAWINGS ARE APPROXIMATE. FIELD VERIFY AND
DETERMINE EXACT LOCATIONS OF ALL PRIVATE WELLS IN THE PROJECT AREA.
8. ALL EXISTING AND NEW UTILITY INFORMATION, INCLUDING BUT NOT LIMITED TO LOCATION, SIZE AND INVERT ELEVATION, IS SHOWN BASED UPON AVAILABLE INFORMATION. THE ENGINEER DOES NOT GUARANTEE OR ASSUME SUCH INFORMATION TO BE TRUE, ACCURATE, ALL INCLUSIVE OR EVEN APPROXIMATE. CONTACT THE INDIANA UNDERGROUND PLANT PROTECTION SERVICE (IUPPS) AT LEAST FORTY-EIGHT (48) HOURS IN
ADVANCE OF ANY CONSTRUCTION ACTIVITY. CONTACT NON-MEMBER UTILITIES DIRECTLY.
9. DETERMINE WHICH UTILITIES MAY CONFLICT WITH WORK AND VERIFY THEIR LOCATION, SIZE AND ELEVATION PRIOR TO CONSTRUCTION AND DETERMINE IF THERE ARE ANY DISCREPANCIES OR CONFLICTS. IF ANY DISCREPANCIES OR CONFLICTS ARE DISCOVERED, NOTIFY THE ENGINEER AS SOON AS POSSIBLE.
10. EXISTING UTILITY SERVICE LINES TO INDIVIDUAL CUSTOMERS MAY NOT BE SHOWN ON THE DRAWINGS.
ASSUME THAT UNDERGROUND SERVICE LINES FOR ALL UTILITIES EXIST TO EACH PROPERTY ALONG THE
ROUTE OF THE PLANNED IMPROVEMENTS.
11. COORDINATE ALL WORK WITH THE RESPECTIVE UTILITIES. SCHEDULE WORK ACCORDINGLY, AND NOTIFY ALL
UTILITIES A MINIMUM OF TWO (2) WEEKS IN ADVANCE OF ANY CONSTRUCTION ACTIVITY.
12. COORDINATE PLANNED UTILITY SERVICE INTERRUPTIONS WITH THE RESPECTIVE UTILITIES AND THE UTILITIES' AFFECTED CUSTOMERS. SERVICE INTERRUPTIONS SHOULD NOT LAST MORE THAN FOUR (4) HOURS. GIVE WRITTEN NOTICE TO ALL AFFECTED UTILITY CUSTOMERS AND PROPERTY OWNERS AT LEAST TWENTY-FOUR (24) HOURS BUT NOT MORE THAN SEVENTY-TWO (72) HOURS PRIOR TO ANY PLANNED
INTERRUPTION OF UTILITY SERVICE.
13. USE CAUTION DURING THE EXECUTION OF WORK TO PREVENT DAMAGE TO EXISTING UTILITIES. REPAIR OR REPLACE ALL PUBLIC AND PRIVATE FACILITIES DAMAGED AS A RESULT OF CONSTRUCTION OPERATIONS.
14. BRACE AND PROTECT ALL UTILITY POLES AND EXISTING STRUCTURES ADJACENT TO NEW EXCAVATIONS.
UTILITY POLE BRACING SHALL BE AS DIRECTED BY THE GOVERNING UTILITY.
15. MAINTAIN EXISTING STORMWATER DRAINAGE FOR THE ENTIRE DURATION OF THE PROJECT.
16. DO NOT DISTURB EXISTING MANHOLES OR INLETS, UNLESS NOTED OTHERWISE.
17. COORDINATE STAGING AREA LOCATIONS WITH THE OWNER.
18. ALL CONSTRUCTION TRAFFIC SHALL USE MAJOR ROADS. NO CONSTRUCTION TRAFFIC SHALL USE LOCAL
STREETS FOR INDIRECT ACCESS.
19. TO CONTROL DUST, REMOVE SOIL FROM STREETS USED BY CONSTRUCTION TRAFFIC DAILY, VACUUM AND
WATER AS NECESSARY AND/OR AS DIRECTED BY THE OWNER.
20. NORTHING AND EASTING INFORMATION IS GIVEN AT CENTER OF STRUCTURE UNLESS OTHERWISE NOTED.
21. PLACE NO. 8 CRUSHED AGGREGATE BETWEEN PIPES AT ALL PIPE CROSSINGS TO PREVENT PIPE SETTLEMENT
UNLESS SHOWN OTHERWISE.
22. VERIFY EXISTING SEWER INVERTS AND LOCATIONS PRIOR TO CONSTRUCTION AND DETERMINE IF THERE ARE
ANY DISCREPANCIES OR CONFLICTS.
23. RESET ALL MAILBOXES AND SIGNS DISTURBED BY CONSTRUCTION ACTIVITIES.
TABLE OF ABBREVIATIONS
ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION
AFF ABOVE FINISHED FLOOR IPS IRON PIPE SIZE
ALUM ALUMINUM ISPC INDIANA STATE PLANE
COORDINATE
APP APPARENT LB POUND(S)
APPROX APPROXIMATE(LY) LF LINEAR FEET
ASPH ASPHALT LN LANE
ASSOC ASSOCIATES LS LIFT STATION
ASTM AMERICAN SOCIETY OF TESTING MATERIALS MA EX MATCH EXISTING
AVE AVENUE MJ MECHANICAL JOINT
AVG AVERAGE MATL MATERIAL
BLDG BUILDING MAX MAXIMUM
BLVD BOULEVARD MH MANHOLE
BM BENCHMARK MIN MINIMUM
CO CLEANOUT MISC MISCELLANEOUS
CI CAST IRON MNFR MANUFACTURER
CL CENTER LINE N NORTHING, NORTH
CMA COLD MIX ASPHALT NGS NATIONAL GEODETIC SURVEY
CMP CORRUGATED METAL PIPE NO. NUMBER
CMU CONCRETE MASONRY UNIT OC ON CENTER
CONC CONCRETE OD OUTSIDE DIAMETER
CONT CONTINUOUS PC POINT OF CURVE (BEGIN CURVE)
CNR CORNER POLY POLYETHYLENE
CP CONTROL POINT PI POINT OF INTERSECTION
CPP CORRUGATED PLASTIC PIPE POT POINT ON TANGENT
CR STN CRUSHED STONE PT POINT OF TANGENT (END CURVE)
CYD CUBIC YARD PSI POUNDS PER SQUARE INCH
D DEPTH PT POINT
DI DUCTILE IRON PVC POLYVINYL CHLORIDE
DI MJ DUCTILE IRON MECHANICAL JOINT R RADIUS
DBL DOUBLE ROW RIGHT-OF-WAY
DIA DIAMETER RCP REINFORCED CONCRETE PIPE
DIP DUCTILE IRON PIPE RD ROAD
DIPS DUCTILE IRON PIPE SIZE S SOUTH
DR DRIVE SR STATE ROUTE
E EASTING, EAST SST STAINLESS STEEL
EF EACH FACE SVA SERVICE VALVE ASSEMBLY
EW EACH WAY SB SOIL BORING
EA EACH SCHED SCHEDULE
EJ EAST JORDAN IRON WORKS SDR STANDARD DIMENSION RATIO
EL ELEVATION SECT SECTION
EX EXISTING SF SQUARE FEET
EXP EXPANSION SHT SHEET
FFE FINISH FLOOR ELEVATION SPECS SPECIFICATION(S)
FM FORCE MAIN SQ SQUARE
FND FOUND SRF STATE REVOLVING FUND
FT FEET ST STREET
FTG FOOTING STA STATION
GALV GALVANIZED SYD SQUARE YARD
GPS GLOBAL POSITIONING SYSTEM TBM TEMPORARY BENCHMARK
HMA HOT MIX ASPHALT TC TOP OF CASTING
HDPE HIGH DENSITY POLYETHYLENE TYP TYPICAL
HORIZ HORIZONTAL UNO UNLESS NOTED OTHERWISE
ID INSIDE DIAMETER USGS US GEOLOGICAL SURVEY
IE INVERT ELEVATION VERT VERTICAL
INC INCORPORATED VLV VALVE
INDOT INDIANA DEPARTMENT OF
TRANSPORTATION W WIDTH, WEST
INSTR INSTRUMENT WSE WATER SURFACE ELEVATION
INV INVERT YR YEAR
*NOTE: THIS TABLE IS A LISTING OF TYPICAL ABBREVIATIONS AND MAY NOT INCLUDE ALL ABBREVIATIONS FOUND WITHIN THIS PLAN SET. IF A QUESTION ARISES ON THE MEANING OF AN ABBREVIATION NOT LISTED IN THIS TABLE, PLEASE CONTACT THE
ENGINEER FOR CLARIFICATION.
EXISTING FEATURES LEGEND
SYMBOL DESCRIPTION DESCRIPTION
BENCH MARK
GROUND LIGHT
TEMPORARY BENCH MARK
MAILBOX
SOIL BORING LOCATION
DOUBLE/MULTIPLE MAILBOX
SECTION CORNER
SIGN - SINGLE POST
CONTROL POINT (SET/FOUND)
SIGN - DOUBLE POST
MAGNETIC NAIL (SET/FOUND)
SIGN - RAILROAD SIGNAL
BOAT SPIKE (SET/FOUND)
SIGN - RAILROAD CROSSING
PK NAIL (SET/FOUND)
TREE - CONIFEROUS
RAILROAD SPIKE (SET/FOUND)
TREE - DECIDUOUS
R/W MARKER - CONCRETE/GRANITE/STONE
STUMP
IRON PIPE/IRON PIN/REBAR (WITH DIAMETER)
ELECTRIC MANHOLE
GAS MANHOLE
WATER MANHOLE
TELEPHONE MANHOLE
TRAFFIC MANHOLE
TRAFFIC HANDHOLE
SANITARY SEWER MANHOLE
DRAINAGE/STORM SEWER MANHOLE
SANITARY SEWER CLEANOUT
CURB INLET
CATCH BASIN
GAS METER
GAS VALVE
GAS SERVICE VALVE
PETROLEUM VALVE
PETROLEUM SHUTOFF VALVE
GAS STATION MONITORING WELL
GAS STATION FILL CAP
NATURAL GAS WELL/STORAGE WELL
WATER METER
WATER VALVE
WATER SERVICE VALVE
WATER WELL
FIRE HYDRANT
CISTERN
ELECTRIC METER
UTILITY PEDESTAL (DEFINED BY UTILITY)
UTILITY MARKER (DEFINED BY UTILITY)
JOINT POWER/TELEPHONE POLE
LIGHT POLE
LIGHT ON POWER POLE
LIGHT ON JOINT POLE
POWER POLE
TELEPHONE POLE
GUY ANCHOR
GUY POLE OR STUB
FLAG POLE
POST
LAMP POST
BM
TBM
SB 01
H Y D
WSO
P SO
PV
GSO
GV
GM
CO
D
H
I
T
W
G
E
R/W
RS
PK
BS
MG
CP
*NOTE: THIS TABLE IS A LISTING OF TYPICAL EXISTING SYMBOLS AND MAY NOT INCLUDE ALL EXISTING SYMBOLS FOUND WITHIN THIS PLAN SET. ALL PROPOSED ITEMS WILL BE CALLED OUT ON THEIR PLAN SHEETS. IF A QUESTION ARISES ON THE MEANING OF ANY SYMBOL NOT LISTED IN THIS TABLE, PLEASE
CONTACT THE ENGINEER FOR CLARIFICATION. THE SYMBOLS ARE NOT TO SCALE.
DESCRIPTIONSYMBOL
AIR CONDITIONING UNIT
ROCK OUTCROP
BEEHIVE INLET
BRASS PLUGBP
CONTROLLER CABINET
DROP INLET
AIR RELEASE VALVE
DRILL HOLE IN CONCRETE/HARRISON MONUMENT
DOWNSPOUT
C CABLE TV MANHOLE
UTILITY RISER (DEFINED BY UTILITY)
MAST ARM POLE
O OTHER MANHOLE
SATELLITE
TRAFFIC SIGNAL STRAIN POLE
SPRINKLER HEADS PH
SPRINKLER CONTROL VALVE
SPH
SIGNAL LOOP DETECTOR BOX
SIGNAL LOOP DETECTOR LOOP
BUSH
AC
TEL TELEPHONE VAULT
WM
WV
WET WELLW W
PROCESS VALVEYARD HYDRANT
VALVE VAULTV V
SEPTIC TANKST
PROPERTY BOUNDARY
RIGHT-OF-WAY - TEMPORARY/PERMANENT
SECTION BOUNDARY
WETLANDS
EASEMENT - CONSTRUCTION/PERMANENT
LOT BOUNDARY
CONTOUR - INTERMEDIATE ELEVATION
CONTOUR - INDEX ELEVATION
OVERHEAD ELECTRIC
OVERHEAD CABLE TV
UNDERGROUND CABLE TV
GAS MAIN
OVERHEAD TELEPHONE
PETROLEUM MAIN
UNDERGROUND ELECTRIC
UNDERGROUND FIBER OPTIC
WATER SERVICE
WATER MAIN
UNDERGROUND TELEPHONE
FORCEMAIN
GRAVITY SEWER PIPE
TOP OF BANK/TOE OF SLOPE
CENTERLINE OF DITCH/SWALE/STREAM
FENCE - FIELD
FENCE - METAL
FENCE - WOOD
GUARDRAIL
TREE/BRUSH LINE
STREAM
DIGESTER GAS
PLANT CHEMICAL LINEAA
S
DS
GW
GFC
GMW
W
CIS
S A T
R R
R R
M M
M
FP
T
P
J
P
L
J
X
XXX
XXX
EM
SYMBOL
PLANT DRAIN LINE
ABBREVIATIONS AND GENERAL NOTES
MRE
CRY
JJH
Dr aw in g:
X :\C ar m el \3
Ca rm el
E m er ge nc y
W M to W
W
TP
\D W
G \S he et s\
-G S.
dw g
L ay ou t:
1G
P lo tte d:
9/
/2
3:
:4
L as tS av ed By
: M ich el le
E
SHEET NO.NO. DATE REVISION DESCRIPTIONSINITIALS
CHECKED BY
APPROVED BY
ISSUE DATE
PROJECT NUMBER
DRAWN BY 96TH ST EMERGENCY WM EXTENSION TO WWTP
CITY OF CARMEL UTILITIES
CARMEL, INDIANA
/01
/20
SCALE VERIFICATION
BAR IS ONE INCH LONG ON
ORIGINAL DRAWING
SEPTEMBER 2026
306726-04-001
TOTAL SHEETS
UTILITY CONTACTS
ELECTRIC/GASTELEPHONE/FIBER OPTIC CITIZENS WATERSEWER
CARMEL UTILITIES, SEWER DEPT.
LANE YOUNG - UTILITY DIRECTOR
TRICO REGIONAL SEWER UTILITY
RYAN HARTMAN - DISTRICT ENGINEER
1-317-660-6604
AT&T
JEFF RICE - PROJECT ENGINEER
1-317-225-3313
JAMIE SCHULTZ
1-989-255-7944
CENTERPOINT ENERGY
CHAD MILLER
1-463-210-7243
CITIZENS GAS
RICH MILLER
1-317-927-4684
DUKE ENERGY
MICAELA MLIKOTA
1-317-776-5341
CARMEL WATER
LANE YOUNG - UTILITY DIRECTOR
1-317-571-2442
STEVE COOK
1-317-733-2858
METRO FIBERNET
LORI KEMPER
1-812-213-1050
CHARTER COMMUNICATIONS
STEVE CREECH
1-317-734-0761
E 96TH STREET
CP CP 6
TBM
TBM 7
SB PSLB NO MARKS
SB PSLB US
WV
W V
H Y D
L
SB PSLB OVER ELECTELTEL
TEL TEL TEL
L
W
0+00
1+00 2+00 3+00 4+00
734735736
(ASPH WALKWAY)
(CONC)
(GRASS)
(GRASS)
(ASPH WALKWAY)
(ASPH)
(ASPH)
EX ROW
EX ROW
EX ROW
AMERICAN AGGREGATES CORP
9825 GRAY ROAD
(PLANTER)
D
TC 740.34
36" RCP IE (E) 724.66
15" RCP IE (E) 734.69
12" RCP IE (SW) 735.51
48" RCP IE (N) 723.69
D
TC 740.20
12" RCP IE (S) 736.20
12" RCP IE (W) 736.20
D
TC 740.17
12" RCP IE (E) 735.96
12" RCP IE (S) 735.86
12" RCP IE (W) 735.76
D
TC 740.13
12" RCP IE (E) 734.83
12" RCP IE (S) 734.98
15" RCP IE (W) 734.73
D
TC 739.91
12" RCP IE (E) 735.59
12" RCP IE (S) 735.41
12" RCP IE (W) 735.08
TC 739.73
4" HDPE IE (SE) 736.63
4" HDPE IE (NW) 737.43
12" RCP IE (NE) 734.63
TC 739.63
4" HDPE IE (E) 737.28
4" HDPE IE (W) 737.28
12" RCP IE (N) 737.28
TC 739.55
4" HDPE IE (SE) 736.45
4" HDPE IE (W) 736.35
12" RCP IE (N) 735.85
TC 739.49
4" HDPE IE (E) 737.02
4" HDPE IE (W) 737.02
12" RCP IE (N) 736.41
TC 739.29
4" HDPE IE (E) 736.24
4" HDPE IE (W) 736.19
12" RCP IE (S) 735.34
12" RCP IE (N) 735.44
D
TC 738.65
36" RCP IE (E) 723.39
12" RCP IE (E) 732.49
36" RCP IE (W) 723.54
D
TC 738.52
36" RCP IE (E) 723.69
36" RCP IE (W) 725.52
D
TC 738.10
TC 737.62
12" RCP IE (W) 735.37
EX 36" RCP EX 36" RCPEX 12" RCP
EX 12" RCP
EX 12" RCP
EX 12" RCP
EX 15" RCP
EX 36" RCP
EX
8" R
CP
EX
" R
CP
EX
2" R
CP
EX
2" R
CP
EX
2" R
CP
EX
2" R
CP
EX 4" HDPE
EX 4" HDPE
EX 4" HDPE
EX 4" HDPE
EX 4" HDPE
EX 4" HDPE
EX
2" R
CP
EX 4" HDPE
EX 4" HDPE
EX 4" HDPE
EX 4" HDPE
PROFILE - PR WM - PipeRun 1
0+50 0+00 1+00 2+00 3+00 4+00 4+50+50 +50 +50 +50
EXISTING GRADE
0+40
12" RCP
IE=±735.40
0+25
15" RCP
IE=±734.72
0+71
12" RCP
IE=±735.42
1+14
12" RCP
IE=±736.12
1+65
12" RCP
IE=±736.72
0+18
36" RCP
IE=±724.86
EX
U
GF
DE
PT
H
UN
KN
OW
N
EX
U
GF
DE
PT
H
UN
KN
OW
N
EX
U
GF
DE
PT
H
UN
KN
OW
N
EX
2" F
M
DE
PT
H
UN
KN
OW
N
PROFILE - LINE A
HORIZ SCALE: 1" = 20'
VERT SCALE: 1" = 5'
5 10 20 FT0
1" = 10'
M
AT
C H
LI
N
E
ST
A 4+
SE
E
SH
EE
T N
O . 5
SCALE: 1"=20'
PLAN - LINE A
Dr aw in g:
X :\C ar m el \3
Ca rm el
E m er ge nc y
W M to W
W
TP
\D W
G \S he et s\
-P P.
dw g
L ay ou t:
PP
P lo tte d:
9/
/2
3:
:5
L as tS av ed By
: M ich el le
E
SHEET NO.NO. DATE REVISION DESCRIPTIONSINITIALS
CHECKED BY
APPROVED BY
ISSUE DATE
PROJECT NUMBER
DRAWN BY 96TH ST EMERGENCY WM EXTENSION TO WWTP
CITY OF CARMEL UTILITIES
CARMEL, INDIANA
/01
/20
SCALE VERIFICATION
BAR IS ONE INCH LONG ON
ORIGINAL DRAWING
SEPTEMBER 2026
306726-04-001
TOTAL SHEETS
PLAN AND PROFILE - LINE A
MRE
CRY
JJH
C MAINTAIN 18" VERTICAL CLEARANCE
BETWEEN PROPOSED WATER AND
SEWER PIPING.
D1 HMA "MULTI-USE PATH REPAIR" AND
FULL DEPTH CLASS 1 BACKFILL. SEE
DETAIL ON SHEET 11
D2 HMA "PARKWAY ARTERIAL" STREET
REPAIR AND FULL DEPTH CLASS 1
BACKFILL. SEE DETAIL ON SHEET 11
F CONCRETE SIDEWALK/RAMP REPAIR
AND FULL DEPTH CLASS 1 BACKFILL.
SEE DETAIL ON SHEET 10
X POTENTIAL UTILITY CONFLICT FIELD
VERIFY PRIOR TO CONSTRUCTION.
IP INLET PROTECTION
SF SILT FENCE OR FILTER TUBE
KEYED NOTES
GENERAL NOTES:
1. INSTALL EROSION AND SEDIMENT CONTROL
MEASURES AS NECESSARY TO PROVIDE
ADEQUATE CONTROL FOR THE
CONSTRUCTION AREA.
2. CONTRACTOR TO REPAIR AND REINSTATE
ANY DAMAGED FIELD TILE WITHIN 24 HOURS
OF OCCURRENCE.
IP
IP
IP
SF
12"x6" MJ REDUCER AND TRANSITION FITTINGS, REMOVE PLUG AND CONNECT TO EXISTING
WATER MAIN
C C
C C
X
385 LF 6" HDPE DR11 WATER
MAIN BY HORIZONTAL
DIRECTIONAL DRILL
EX 12" FM
OPENCUT HDD
6" 22.5° MJ BEND
AND TRANSITION
FITTINGS
F
D1
65 LF 6" HDPE DR11
WATER MAIN BY OPEN CUT
4.5' MIN
6" 45° MJ BEND AND
TRANSITION FITTINGS
6" 45° MJ BEND AND
TRANSITION FITTINGS
C 385 LF 6" HDPE DR11
WATER MAIN BY HDD
65 LF 6" HDPE DR11 WATER
MAIN BY OPEN CUT
HDDOPEN
CUT
CP CP 5
W
TEL
TEL
TEL
R/W
TEL
J R/W
J
5+00 6+00 7+00 8+00 9+00
(ASPH WALKWAY)
(GRASS)
(ASPH)
EX ROW
EX ROW
EX ROW
AMERICAN AGGREGATES CORP
9825 GRAY ROAD
(PLANTER)
D
TC 738.96
36" RCP IE (W) 721.11
D
TC 738.72
12" RCP IE (E) 733.09
36" RCP IE (E) 722.47
36" RCP IE (W) 722.27
TC 738.68
15" RCP IE (E) 733.292339
TC 738.18
12" RCP IE (W) 735.84
EX 36" RCPEX 12" RCPEX 36" RCP
PROFILE - PR WM - PipeRun 1
4+50 5+00 6+00 7+00 8+00 9+00 9+50+50 +50 +50 +50
EXISTING GRADE
EX
U
GF
DE
PT
H
UN
KN
OW
N
PROFILE - LINE A
HORIZ SCALE: 1" = 20'
VERT SCALE: 1" = 5'
5 10 20 FT0
1" = 10'
M
AT
C H
LI
N
E
ST
A 9+
SE
E
SH
EE
T N
O . 6
SCALE: 1"=20'
PLAN - LINE A
Dr aw in g:
X :\C ar m el \3
Ca rm el
E m er ge nc y
W M to W
W
TP
\D W
G \S he et s\
-P P.
dw g
L ay ou t:
PP
P lo tte d:
9/
/2
3:
:1
L as tS av ed By
: M ich el le
E
SHEET NO.NO. DATE REVISION DESCRIPTIONSINITIALS
CHECKED BY
APPROVED BY
ISSUE DATE
PROJECT NUMBER
DRAWN BY 96TH ST EMERGENCY WM EXTENSION TO WWTP
CITY OF CARMEL UTILITIES
CARMEL, INDIANA
/01
/20
SCALE VERIFICATION
BAR IS ONE INCH LONG ON
ORIGINAL DRAWING
SEPTEMBER 2026
306726-04-001
TOTAL SHEETS
PLAN AND PROFILE - LINE A
MRE
CRY
JJH
M
AT
C H
LI
N
E
ST
A 4+
SE
E
SH
EE
T N
O . 4
C MAINTAIN 18" VERTICAL CLEARANCE
BETWEEN PROPOSED WATER AND
SEWER PIPING.
D1 HMA "MULTI-USE PATH REPAIR" AND
FULL DEPTH CLASS 1 BACKFILL. SEE
DETAIL ON SHEET 11
D2 HMA "PARKWAY ARTERIAL" STREET
REPAIR AND FULL DEPTH CLASS 1
BACKFILL. SEE DETAIL ON SHEET 11
F CONCRETE SIDEWALK/RAMP REPAIR
AND FULL DEPTH CLASS 1 BACKFILL.
SEE DETAIL ON SHEET 10
X POTENTIAL UTILITY CONFLICT FIELD
VERIFY PRIOR TO CONSTRUCTION.
IP INLET PROTECTION
SF SILT FENCE OR FILTER TUBE
KEYED NOTES
GENERAL NOTES:
1. INSTALL EROSION AND SEDIMENT CONTROL
MEASURES AS NECESSARY TO PROVIDE
ADEQUATE CONTROL FOR THE
CONSTRUCTION AREA.
2. CONTRACTOR TO REPAIR AND REINSTATE
ANY DAMAGED FIELD TILE WITHIN 24 HOURS
OF OCCURRENCE.
X
500 LF 6" HDPE DR11 WATER
MAIN BY HORIZONTAL
DIRECTIONAL DRILL
EX 12" FM
D1
4.5' MIN
500 LF 6" HDPE DR11
WATER MAIN BY HDD
CP CP 4TEL TEL
R/W
R/W
J TEL
CTV
MG
GM
TEL
TEL
J
ELE
J
10+00 11+00 12+00 13+00 14+00
(ASPH)
(ASPH WALKWAY)
(GRASS)
(ASPH WALKWAY)
EX ROW
EX ROW
AMERICAN AGGREGATES CORP
9825 GRAY ROAD 2306
TC 739.35
15" RCP IE (W) 732.00
15" RCP IE (E) 731.90
42" HDPE IE (S) 730.35
EX 15" RCP
EX
2" H
DP
E
PROFILE - PR WM - PipeRun 1
9+50 10+00 11+00 12+00 13+00 14+00 14+50+50 +50 +50 +50
EXISTING GRADE
EX
U
GT
DE
PT
H
UN
KN
OW
N
12+20
42" HDPE
IE=±730.35
PROFILE - LINE A
HORIZ SCALE: 1" = 20'
VERT SCALE: 1" = 5'
5 10 20 FT0
1" = 10'
M
AT
C H
LI
N
E
ST
A
+5
- S
EE
S H
EE
T
N O
. 7
SCALE: 1"=20'
PLAN - LINE A
Dr aw in g:
X :\C ar m el \3
Ca rm el
E m er ge nc y
W M to W
W
TP
\D W
G \S he et s\
-P P.
dw g
L ay ou t:
PP
P lo tte d:
9/
/2
3:
:2
L as tS av ed By
: M ich el le
E
SHEET NO.NO. DATE REVISION DESCRIPTIONSINITIALS
CHECKED BY
APPROVED BY
ISSUE DATE
PROJECT NUMBER
DRAWN BY 96TH ST EMERGENCY WM EXTENSION TO WWTP
CITY OF CARMEL UTILITIES
CARMEL, INDIANA
/01
/20
SCALE VERIFICATION
BAR IS ONE INCH LONG ON
ORIGINAL DRAWING
SEPTEMBER 2026
306726-04-001
TOTAL SHEETS
PLAN AND PROFILE - LINE A
MRE
CRY
JJH
M
AT
C H
LI
N
E
ST
A 9+
SE
E
SH
EE
T N
O . 5
C MAINTAIN 18" VERTICAL CLEARANCE
BETWEEN PROPOSED WATER AND
SEWER PIPING.
D1 HMA "MULTI-USE PATH REPAIR" AND
FULL DEPTH CLASS 1 BACKFILL. SEE
DETAIL ON SHEET 11
D2 HMA "PARKWAY ARTERIAL" STREET
REPAIR AND FULL DEPTH CLASS 1
BACKFILL. SEE DETAIL ON SHEET 11
F CONCRETE SIDEWALK/RAMP REPAIR
AND FULL DEPTH CLASS 1 BACKFILL.
SEE DETAIL ON SHEET 10
X POTENTIAL UTILITY CONFLICT FIELD
VERIFY PRIOR TO CONSTRUCTION.
IP INLET PROTECTION
SF SILT FENCE OR FILTER TUBE
KEYED NOTES
GENERAL NOTES:
1. INSTALL EROSION AND SEDIMENT CONTROL
MEASURES AS NECESSARY TO PROVIDE
ADEQUATE CONTROL FOR THE
CONSTRUCTION AREA.
2. CONTRACTOR TO REPAIR AND REINSTATE
ANY DAMAGED FIELD TILE WITHIN 24 HOURS
OF OCCURRENCE.
C
X
500 LF 6" HDPE DR11 WATER
MAIN BY HORIZONTAL
DIRECTIONAL DRILL
EX 12" FM
D1
4.5' MIN
500 LF 6" HDPE DR11
CP CP 3
R/W
R/W
R/W
J
A
J
JJ
I I
GM
TEL
J
ELE
15+00 16+00 17+00 18+00
19+00
742 743 744 745
(GRASS)
(GRASS)
(ASPH WALKWAY)(ASPH WALKWAY)
(ASPH)
(ASPH)
(CONC)
EX ROW
(ASPH)
(CONC) (CONC)
AMERICAN AGGREGATES CORP
9825 GRAY ROAD
A
A
PROFILE - PR WM - PipeRun 1
14+50 15+00 16+00 17+00 18+00 19+00 19+50+50 +50 +50 +50
EXISTING GRADE
EX
G
AS
DE
PT
H
UN
KN
OW
N
EX
U
GC
DE
PT
H
UN
KN
OW
N
EX
U
GF
DE
PT
H
UN
KN
OW
N
EX
U
GF
DE
PT
H
UN
KN
OW
N
EX
U
GF
DE
PT
H
UN
KN
OW
N
17+72
6" HDPE
IE=±740.30
PROFILE - LINE A
HORIZ SCALE: 1" = 20'
VERT SCALE: 1" = 5'
5 10 20 FT0
1" = 10'
M
AT
C H
LI
N
E
ST
A
+5
- S
EE
S H
EE
T
N O
. 8
SCALE: 1"=20'
PLAN - LINE A
Dr aw in g:
X :\C ar m el \3
Ca rm el
E m er ge nc y
W M to W
W
TP
\D W
G \S he et s\
-P P.
dw g
L ay ou t:
PP
P lo tte d:
9/
/2
3:
:3
L as tS av ed By
: M ich el le
E
SHEET NO.NO. DATE REVISION DESCRIPTIONSINITIALS
CHECKED BY
APPROVED BY
ISSUE DATE
PROJECT NUMBER
DRAWN BY 96TH ST EMERGENCY WM EXTENSION TO WWTP
CITY OF CARMEL UTILITIES
CARMEL, INDIANA
/01
/20
SCALE VERIFICATION
BAR IS ONE INCH LONG ON
ORIGINAL DRAWING
SEPTEMBER 2026
306726-04-001
TOTAL SHEETS
PLAN AND PROFILE - LINE A
MRE
CRY
JJH
M
AT
C H
LI
N
E
ST
A
+5
- S
EE
S H
EE
T
N O
. 6
C MAINTAIN 18" VERTICAL CLEARANCE
BETWEEN PROPOSED WATER AND
SEWER PIPING.
D1 HMA "MULTI-USE PATH REPAIR" AND
FULL DEPTH CLASS 1 BACKFILL. SEE
DETAIL ON SHEET 11
D2 HMA "PARKWAY ARTERIAL" STREET
REPAIR AND FULL DEPTH CLASS 1
BACKFILL. SEE DETAIL ON SHEET 11
F CONCRETE SIDEWALK/RAMP REPAIR
AND FULL DEPTH CLASS 1 BACKFILL.
SEE DETAIL ON SHEET 10
X POTENTIAL UTILITY CONFLICT FIELD
VERIFY PRIOR TO CONSTRUCTION.
IP INLET PROTECTION
SF SILT FENCE OR FILTER TUBE
KEYED NOTES
GENERAL NOTES:
1. INSTALL EROSION AND SEDIMENT CONTROL
MEASURES AS NECESSARY TO PROVIDE
ADEQUATE CONTROL FOR THE
CONSTRUCTION AREA.
2. CONTRACTOR TO REPAIR AND REINSTATE
ANY DAMAGED FIELD TILE WITHIN 24 HOURS
OF OCCURRENCE.
X X X X
C
500 LF 6" HDPE DR11 WATER
MAIN BY HORIZONTAL
DIRECTIONAL DRILL
EX 12" FM
EX 12" FM
EXISTING ARV
EXISTING ARV
D1 D1
4.5' MIN
500 LF 6" HDPE DR11
WATER MAIN BY HDD
D1 D1 D1
CP CP 2
GV
J G
J
20+00 21+00 22+00
(ASPH)
(ASPH WALKWAY)
(GRASS)
(ASPH WALKWAY)
EX ROW EX ROW
AMERICAN AGGREGATES CORP
9825 GRAY ROAD
D
TC 747.08
12" RCP IE (S) 741.45
12" RCP IE (W) 741.45
12" RCP IE (E) 741.55
D
TC 746.47
12" RCP IE (W) 741.12
12" RCP IE (E) 741.07
TC 746.37
6" HDPE IE (W) 743.62
6" HDPE IE (E) 743.62
12" RCP IE (N) 742.22
EX 12" RCP
EX
2" R
CP
PROFILE - PR WM - PipeRun 1
19+50 20+00 21+00 22+00 22+50+50 +50
EXISTING GRADE
PROFILE - LINE A
HORIZ SCALE: 1" = 20'
VERT SCALE: 1" = 5'
5 10 20 FT0
1" = 10'
M
AT
C H
LI
N
E
ST
A
+5
- S
EE
S H
EE
T
N O
. 9
SCALE: 1"=20'
PLAN - LINE A
Dr aw in g:
X :\C ar m el \3
Ca rm el
E m er ge nc y
W M to W
W
TP
\D W
G \S he et s\
-P P.
dw g
L ay ou t:
PP
P lo tte d:
9/
/2
3:
:4
L as tS av ed By
: M ich el le
E
SHEET NO.NO. DATE REVISION DESCRIPTIONSINITIALS
CHECKED BY
APPROVED BY
ISSUE DATE
PROJECT NUMBER
DRAWN BY 96TH ST EMERGENCY WM EXTENSION TO WWTP
CITY OF CARMEL UTILITIES
CARMEL, INDIANA
/01
/20
SCALE VERIFICATION
BAR IS ONE INCH LONG ON
ORIGINAL DRAWING
SEPTEMBER 2026
306726-04-001
TOTAL SHEETS
PLAN AND PROFILE - LINE A
MRE
CRY
JJH
M
AT
C H
LI
N
E
ST
A
+5
- S
EE
S H
EE
T
N O
. 7
C MAINTAIN 18" VERTICAL CLEARANCE
BETWEEN PROPOSED WATER AND
SEWER PIPING.
D1 HMA "MULTI-USE PATH REPAIR" AND
FULL DEPTH CLASS 1 BACKFILL. SEE
DETAIL ON SHEET 11
D2 HMA "PARKWAY ARTERIAL" STREET
REPAIR AND FULL DEPTH CLASS 1
BACKFILL. SEE DETAIL ON SHEET 11
F CONCRETE SIDEWALK/RAMP REPAIR
AND FULL DEPTH CLASS 1 BACKFILL.
SEE DETAIL ON SHEET 10
X POTENTIAL UTILITY CONFLICT FIELD
VERIFY PRIOR TO CONSTRUCTION.
IP INLET PROTECTION
SF SILT FENCE OR FILTER TUBE
KEYED NOTES
GENERAL NOTES:
1. INSTALL EROSION AND SEDIMENT CONTROL
MEASURES AS NECESSARY TO PROVIDE
ADEQUATE CONTROL FOR THE
CONSTRUCTION AREA.
2. CONTRACTOR TO REPAIR AND REINSTATE
ANY DAMAGED FIELD TILE WITHIN 24 HOURS
OF OCCURRENCE.
300 LF 6" HDPE DR11 WATER
MAIN BY HORIZONTAL
DIRECTIONAL DRILL
EX 12" FM
4.5' MIN
300 LF 6" HDPE DR11
H
AZ
EL
D
EL
L
PA
R
KW
AY
E 96TH STREET
CP CP 1
CP CP 2
TBM
TBM 8
MG
L
TEL L
J
J
WV
W V
H
Y D WV
W
TEL
GV
G
L
F
TELTEL
J
ELE TEL
J
26+12
23+00
24+00
25+00
26+00
749750
751752
(GRASS)
(ASPH)
(ASPH WALKWAY)
(ASPH WALKWAY)
(CONC)
(LANDSCAPE)
(ASPH WALKWAY)
(CONC)
(ASPH)
(ASPH)
(GRASS)
EX ROW
EX ROW
EX ROW
EX ROW
E 96TH STREET
AMERICAN AGGREGATES CORP
9825 GRAY ROAD
CITY OF CARMEL
9609 HAZEL DELL PKWY
D
TC 746.97
15" RCP IE (W) 739.97
15" RCP IE (NE) 739.97
D
TC 746.78
15" RCP IE (SW) 739.78
12" RCP IE (SE) 739.93
15" RCP IE (NE) 739.78
D
TC 746.47
12" RCP IE (W) 741.12
12" RCP IE (E) 741.07
D
TC 746.45
15" RCP IE (SW) 739.50
12" RCP IE (SE) 739.45
15" RCP IE (NE) 739.50
D
TC 746.33
15" RCP IE (W) 740.28
12" RCP IE (S) 740.23
15" RCP IE (E) 740.23
TC 746.15
6" HDPE IE (NE) 742.90
6" HDPE IE (SW) 742.90
12" RCP IE (NW) 739.85
D
TC 746.03
15" RCP IE (W) 740.68
15" RCP IE (S) 740.63
15" RCP IE (E) 740.63
TC 745.78
6" HDPE IE (NE) 742.38
6" HDPE IE (SW) 742.38
12" RCP IE (NW) 740.18
TC 745.56
6" HDPE IE (W) 742.23
6" HDPE IE (E) 742.23
12" RCP IE (N) 740.11
D
TC 745.43
36" RCP IE (W) 737.48
12" RCP IE (N) 738.94
24" RCP IE (E) 737.46
TC 745.30
6" HDPE IE (W) 741.95
6" HDPE IE (E) 741.95
15" RCP IE (N) 740.40
TC 744.88
24" RCP IE (NW) 737.80
6" HDPE IE (N) 741.03
6" HDPE IE (S) 741.03
36" RCP IE (E) 737.93
D
TC 73909.00
12" RCP IE (E) 739.00
12" RCP IE (SW) 739.05
6" HDPE IE (NE) 740.15
12" RCP IE (NW) 739.00
D
TC 743.86
12" RCP IE (SE) 738.00
24" RCP IE (E) 737.38
24" RCP IE (N) 737.38
D
TC 743.71
D
TC 743.42
12" RCP IE (E) 739.22
12" RCP IE (S) 739.09
12" RCP IE (W) 738.98
TC 743.28
6" HDPE IE (NW) 740.07
6" HDPE IE (E) 740.07
12" RCP IE (NE) 739.23
D
TC 743.10
TC 742.74
6" HDPE IE (W) 739.94
6" HDPE IE (E) 739.94
12" RCP IE (N) 739.11
EX 12" RCP
EX 12" RCP
EX 15" RCP
EX 15" RCP
EX 15
" R
CP
EX 15
" R
CP
EX 15
" R
CP
EX 12" RCP
EX 12" RCP
EX
" R
CP
EX
5" R
CP
EX 6"
HDPE
EX
6"
HDPE
D
(ASPH)
PROFILE - PR WM - PipeRun 1
22+50 23+00 24+00 25+00 26+00 27+00+50 +50 +50 +50
EXISTING GRADE
26+05
6" HDPE
IE=±741.03
26+00
24" RCP
IE=±737.85
EX
2" F
M
DE
PT
H
UN
KN
OW
N
EX
U
GE
DE
PT
H
UN
KN
OW
N
EX
U
GF
DE
PT
H
UN
KN
OW
N
EX
U
GE
DE
PT
H
UN
KN
OW
N
EX
U
GE
DE
PT
H
UN
KN
OW
N
EX
U
GF
DE
PT
H
UN
KN
OW
N
EX
U
GE
DE
PT
H
UN
KN
OW
N
EX
2" F
M
DE
PT
H
UN
KN
OW
N
EX
6" T
RI
CO
F M
DE
PT
H
UN
KN
OW
N
PROFILE - LINE A
HORIZ SCALE: 1" = 20'
VERT SCALE: 1" = 5'
5 10 20 FT0
1" = 10'
SCALE: 1"=20'
PLAN - LINE A
Dr aw in g:
X :\C ar m el \3
Ca rm el
E m er ge nc y
W M to W
W
TP
\D W
G \S he et s\
-P P.
dw g
L ay ou t:
PP
P lo tte d:
9/
/2
3:
:5
L as tS av ed By
: M ich el le
E
SHEET NO.NO. DATE REVISION DESCRIPTIONSINITIALS
CHECKED BY
APPROVED BY
ISSUE DATE
PROJECT NUMBER
DRAWN BY 96TH ST EMERGENCY WM EXTENSION TO WWTP
CITY OF CARMEL UTILITIES
CARMEL, INDIANA
/01
/20
SCALE VERIFICATION
BAR IS ONE INCH LONG ON
ORIGINAL DRAWING
SEPTEMBER 2026
306726-04-001
TOTAL SHEETS
PLAN AND PROFILE - LINE A
MRE
CRY
JJH
M
AT
C H
LI
N
E
ST
A 0+
SE
E
SH
EE
T N
O . 8
C MAINTAIN 18" VERTICAL CLEARANCE
BETWEEN PROPOSED WATER AND
SEWER PIPING.
D1 HMA "MULTI-USE PATH REPAIR" AND
FULL DEPTH CLASS 1 BACKFILL. SEE
DETAIL ON SHEET 11
D2 HMA "PARKWAY ARTERIAL" STREET
REPAIR AND FULL DEPTH CLASS 1
BACKFILL. SEE DETAIL ON SHEET 11
F CONCRETE SIDEWALK/RAMP REPAIR
AND FULL DEPTH CLASS 1 BACKFILL.
SEE DETAIL ON SHEET 10
X POTENTIAL UTILITY CONFLICT FIELD
VERIFY PRIOR TO CONSTRUCTION.
IP INLET PROTECTION
SF SILT FENCE OR FILTER TUBE
KEYED NOTES
GENERAL NOTES:
1. INSTALL EROSION AND SEDIMENT CONTROL
MEASURES AS NECESSARY TO PROVIDE
ADEQUATE CONTROL FOR THE
CONSTRUCTION AREA.
2. CONTRACTOR TO REPAIR AND REINSTATE
ANY DAMAGED FIELD TILE WITHIN 24 HOURS
OF OCCURRENCE.
IP
X
EX
2" F
M
EX
6" T
RI
CO
F M
12"x6" MJ REDUCER AND TRANSITION FITTINGS.
REMOVE PLUG AND CONNECT TO EXISTING
WATER MAIN
362 LF 6" HDPE DR11
WATER MAIN BY
HORIZONTAL
DIRECTIONAL DRILL
EX 12" FM
D2
X X
D2 D2
X
D2
X
D2
X
D2
F
362 LF 6" HDPE DR11
WATER MAIN BY HDD
C
C
4.5' MIN
6" 45° MJ VERTICAL BEND
(TYP OF 2)
MISCELLANEOUS DETAILS
MRE
CRY
JJH
Dr aw in g:
X :\C ar m el \3
Ca rm el
E m er ge nc y
W M to W
W
TP
\D W
G \S he et s\
-M D.
dw g
L ay ou t:
M
D1
P lo tte d:
9/
/2
3:
:5
L as tS av ed By
: M ich el le
E
SHEET NO.NO. DATE REVISION DESCRIPTIONSINITIALS
CHECKED BY
APPROVED BY
ISSUE DATE
PROJECT NUMBER
DRAWN BY 96TH ST EMERGENCY WM EXTENSION TO WWTP
CITY OF CARMEL UTILITIES
CARMEL, INDIANA
/01
/20
SCALE VERIFICATION
BAR IS ONE INCH LONG ON
ORIGINAL DRAWING
SEPTEMBER 2026
306726-04-001
TOTAL SHEETS
18" MINIMUM
NOTES:
1. WATER MAIN AND SEWER MINIMUM SEPARATION: 18"
VERTICAL SEPARATION 10'-0" HORIZONTAL SEPARATION.
2. WHERE WATER MAIN AND SEWER SEPARATION IS LESS
THAN 18" VERTICAL OR 10' HORIZONTAL, THE SEWER
MUST BE DUCTILE IRON OR SDR-21 PVC.
SANITARY OR STORM
SEWER MAIN
CENTER OF SEWER
MAIN LAYING LENGTH
WATER MAIN
CENTER OF SEWER
MAIN LAYING LENGTH
SANITARY OR STORM
SEWER MAIN
WATER MAIN
SCALE: NONE
MINIMUM CROSSOVER AND
SEPARATION REQUIREMENTS FOR
SEWER AND WATER MAINS
HDPE
WATER MAIN
MJ TEE BEND
OR VALVE
HDPE
WATER MAIN
HARVEY STYLE
MJ ADAPTER
SCALE:
HDPE FITTING TRANSITION
NONE
24" MINIMUM
WIDTH MINIMUM
SEE BELOW
BRACING AREA OF
CONCRETE COLLAR WIDTH MINIMUM
5 SF
PIPE SIZE
6" 3'-0"
3'-6"9 SF8"
14"
PLAN VIEW
4'-9"21 SF16"
5'-0"24 SF20"
2.25 SF4" 1'-6"
4'-3"18 SF12"
_'-_"__ SF10"
18"
_'-_"__ SF
_'-_"__ SF
DI OR PVC
WATER MAIN
PUSH-ON JOINT OR
FITTING RESTRAINT
MJ
RESTRAINED
JOINT GLAND
MJ
SLEEVE
HARVEY STYLE MJ
ADAPTER
SQUARE CONCRETE COLLAR
(FORMED AND CAST IN PLACE)
TRENCH WALL
(UNDISTURBED EARTH)
HDPE WATER
MAIN
HARVEY
STYLE MJ
ADAPTER
HDPE WATER-STOP
OR GRIP RING
SCALE:
HDPE PIPE TRANSITION
NONE
TYPE A CONSTRUCTION WARNING LIGHT
WORKSITE ADDED PENALTY (G20-7) ONLY FOR INDOT ROADS
"ROAD WORK - XXX FT" (W20-1)
"ONE LANE ROAD AHEAD" (W20-4)
"END ROAD WORK" (G20-2)
ROAD CLOSURE SIGN ASSEMBLY, INCLUDES R11-2, BARRICADE
TYPE IIIB, AND TYPE B CONSTRUCTION WARNING LIGHT
"ROAD WORK AHEAD" (W20-1) OR "UTILITY WORK AHEAD" (W21-7)
FLAGGER
5 FLAGGER SIGN (W20-7)
BARRICADE TYPE IIIB
TRAFFIC CONTROL DRUM
TRAFFIC FLOW DIRECTION
WORK AREA(S)
SIGN, FACING LEFT
SIGN, FACING RIGHT
SCALE:
TRAFFIC CONTROL LEGEND
NONE
SPEED
(MPH)
DISTANCE (FEET)
A B C D E
20 OR LESS 120 100 100 100 100
25 160 100 100 100
30 200 100 100 100
35 280 350 350 350
40 320 350 350 350
45 360 500 500 500
50 440 500 500 500
55 520 500 500 500
60 600 1,600 2,6401,000
65 680 1,600 2,6401,000
70 760 1,600 2,6401,000
NOTES:
1. DISTANCES SHOWN ARE APPROXIMATE. ADJUST SIGN FOR
CURVES, HILLS, INTERSECTIONS, DRIVEWAYS, ETC TO IMPROVE
SIGN VISIBILITY.
2. THE SPACING OF CHANNELIZING DEVICES SHOULD BE A DISTANCE
IN FEET EQUAL TO THE SPEED LIMIT IN MPH WHEN USED FOR
TAPER CHANNELIZATION, AND A DISTANCE IN FEET EQUAL TO 2.0
TIMES THE SPEED LIMIT IN MPH USED FOR TANGENT
CHANNELIZATION.
SCALE: NONE
ADVANCE WARNING SIGN AND
FLAGGER OPERATION SPACING
WORK AREA
ABCDE B
C D E
2 4 5
5 4 2
SCALE:
TEMPORARY FLAGGER OPERATION
NONE
MISCELLANEOUS DETAILS
MRE
CRY
JJH
Dr aw in g:
X :\C ar m el \3
Ca rm el
E m er ge nc y
W M to W
W
TP
\D W
G \S he et s\
-M D.
dw g
L ay ou t:
M
D2
P lo tte d:
9/
/2
3:
:5
L as tS av ed By
: M ich el le
E
SHEET NO.NO. DATE REVISION DESCRIPTIONSINITIALS
CHECKED BY
APPROVED BY
ISSUE DATE
PROJECT NUMBER
DRAWN BY 96TH ST EMERGENCY WM EXTENSION TO WWTP
CITY OF CARMEL UTILITIES
CARMEL, INDIANA
/01
/20
SCALE VERIFICATION
BAR IS ONE INCH LONG ON
ORIGINAL DRAWING
SEPTEMBER 2026
306726-04-001
TOTAL SHEETS
EROSION CONTROL DETAILS
MRE
CRY
JJH
Dr aw in g:
X :\C ar m el \3
Ca rm el
E m er ge nc y
W M to W
W
TP
\D W
G \S he et s\
-M D.
dw g
L ay ou t:
CD
P lo tte d:
9/
/2
3:
:0
L as tS av ed By
: M ich el le
E
SHEET NO.NO. DATE REVISION DESCRIPTIONSINITIALS
CHECKED BY
APPROVED BY
ISSUE DATE
PROJECT NUMBER
DRAWN BY 96TH ST EMERGENCY WM EXTENSION TO WWTP
CITY OF CARMEL UTILITIES
CARMEL, INDIANA
/01
/20
SCALE VERIFICATION
BAR IS ONE INCH LONG ON
ORIGINAL DRAWING
SEPTEMBER 2026
306726-04-001
TOTAL SHEETS
EROSION CONTROL SCHEDULE
CONSTRUCTION ACTIVITY SCHEDULE CONSIDERATION
REVIEW THE EROSION CONTROL SCHEDULE ON THE
DRAWINGS AND REVISE AS NEEDED TO PHASE
CONSTRUCTION ACTIVITIES TO MINIMIZE THE FOOTPRINT OF
DISTURBED UNSTABLE AREAS. SUBMIT A REVISED EROSION
CONTROL SCHEDULE AS NEEDED FOR TEMPORARY AND
PERMANENT EROSION CONTROL WORK AS APPLICABLE.
CONSTRUCTION ACCESS - ENTRANCE TO SITE,
CONSTRUCTION ROUTES, AREAS DESIGNATED FOR
EQUIPMENT PARKING OR MATERIAL STAGING AND
WASTE HANDLING.
THIS IS THE FIRST LAND-DISTURBING ACTIVITY. AS
SOON AS CONSTRUCTION BEGINS, STABILIZE ANY
BARE AREAS WITH AGGREGATE AND TEMPORARY
VEGETATION.
SEDIMENT TRAPS AND BARRIERS - BASIN TRAPS, SILT
FENCE AND PERIMETER PROTECTION.
AFTER CONSTRUCTION IS ACCESSED, BASINS SHALL
BE INSTALLED, WITH THE ADDITION OF MORE TRAPS
AND BARRIERS AS NEEDED DURING GRADING. SET UP
PROTECTION FOR NATURAL FEATURES, TREES AND
BUFFERS.
RUNOFF CONTROL - DIVERSIONS, PERIMETER
PROTECTION, CHECK DAMS, OUTLET PROTECTION.
RUNOFF CONTROL PRACTICES SHALL BE INSTALLED
AFTER THE INSTALLATION OF SEDIMENT TRAPS AND
BEFORE LAND GRADING. ADDITIONAL RUNOFF
CONTROL MEASURES MAY BE INSTALLED DURING
GRADING.
RUNOFF CONVEYANCE SYSTEM - STABILIZE STREAM
BANKS, STORM DRAINS, CHANNELS, INLET AND
OUTLET PROTECTION, SLOPE DRAINS.
AS NECESSARY, STABILIZE STREAM BANKS AND SIDE
SLOPES OF RUNOFF SYSTEMS AS SOON AS POSSIBLE.
USE EROSION CONTROL BLANKETS OR SLOPE DRAINS
TO PREVENT EROSION. INSTALL INLET PROTECTION
TO PREVENT SEDIMENTS FROM ENTERING STORM
DRAINAGE SYSTEMS. PROTECT STORM OUTLETS TO
PREVENT EROSION.
LAND CLEARING AND GRADING - SITE PREPARATION
(CUTTING, FILLING, AND GRADING, SEDIMENT TRAPS,
BARRIERS, DIVERSIONS, DRAINS, SURFACE
ROUGHENING).
IMPLEMENT CLEARING AND GRADING AFTER
INSTALLATION OF SEDIMENT TRAPS AND RUNOFF
CONTROL MEASURES, AND INSTALL ADDITIONAL
CONTROL MEASURES AS GRADING CONTINUES. CLEAR
BORROW AND DISPOSAL AREAS AS NEEDED.
SURFACE STABILIZATION - TEMPORARY AND
PERMANENT SEEDING, MULCHING, SODDING, RIPRAP,
EROSION CONTROL BLANKET.
APPLY TEMPORARY OR PERMANENT STABILIZING
MEASURES IMMEDIATELY TO ANY DISTURBED AREAS
WHERE WORK HAS BEEN EITHER COMPLETED OR
DELAYED.
CONSTRUCTION - STRUCTURES, UTILITIES, PAVING,
CONCRETE WASHOUT, AND CONSTRUCTION
ENTRANCES.
DURING CONSTRUCTION, INSTALL ANY EROSION AND
SEDIMENTATION CONTROL MEASURES THAT ARE
NEEDED.
LANDSCAPING AND FINAL STABILIZATION -
TOPSOILING, TREES AND SHRUBS, PERMANENT
SEEDING, MULCHING, SODDING, RIPRAP.
THIS IS THE LAST CONSTRUCTION PHASE. STABILIZE ALL
DISTURBED AREAS, INCLUDING BORROW AND SPOIL
AREAS, AND REMOVE ALL TEMPORARY CONTROL
MEASURES. FINAL STABILIZATION IS WHEN A UNIFORM
DENSITY OF 70% VEGETATION COVER IS MET. PROVIDE
NOTIFICATION TO THE OWNER WHEN THE ENTIRE SITE
HAS BEEN STABILIZED AND ALL CONSTRUCTION
MATERIALS, WASTES, AND EQUIPMENT HAVE BEEN
REMOVED.
COMPLETE BEFORE CONSTRUCTION BEGINS.
SCALE:
EROSION CONTROL SCHEDULE
NONE
LADEN FLOW
SLO
PE
SLO
PE
APPLICATIONS:
1. TOP OF SLOPES.
2. AT PROJECT PERIMETER.
INSTALLATION:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
2. USE THE APPROPRIATE SIZE, LENGTH AND DISTANCE BETWEEN TUBES AS
SPECIFIED BY THE MANUFACTURER.
3. ENTRENCH PER MANUFACTURER'S INSTRUCTIONS.
MAINTENANCE:
1. REMOVE ALL ACCUMULATED SEDIMENT WHEN IT REACHES 1/4 THE HEIGHT OF
THE TUBE.
2. REPAIR ERODED AND DAMAGED AREAS.
3. IF PONDING BECOMES EXCESSIVE DUE TO REDUCED FILTERING CAPACITY,
REMOVE THE TUBE AND EITHER RECONSTRUCT OR REPLACE WITH NEW
PRODUCT.
4. INSPECT WITHIN 24 HOURS OF A RAIN EVENT AND AT LEAST ONCE EVERY 7
CALENDAR DAYS.
SEDIMENT
SLOPE
SLOPE SLOPE DETAIL
VIEW OF
OVERLAPPED TUBES
DOWNSLOPE
STAKE DETAILS
FIBER
FILTRATION TUBE
SLOPE
SURFACE
FIBER
FILTRATION
TUBE
STAKE DEPTH
PER MANUFACTURER'S
INSTRUCTIONS
WOOD STAKE
WOOD STAKE TO
ONLY PENETRATE NETTING
TOP EROSION CONTROL
BLANKET
WOOD
STAKE EROSION
CONTROL BLANKET
FIBER
FILTRATION
TUBES
SCALE:
FIBER FILTRATION TUBES - SLOPE
NONE
PRODUCT:
1. DANDY CURB SACK, OR APPROVED EQUAL.
INSTALLATION:
1. REMOVE THE GRATE FROM THE CATCH BASIN AND STAND ON END.
2. CRADLE THE GRATE BETWEEN THE UPPER AND LOWER STRAPS.
3. INSERT THE GRATE INTO THE INLET WITH THE LIFTING DEVICES. LOWER BACK
EDGE WITH TUBE INTO PLACE. TUBE SHOULD PARTIALLY BLOCK THE CURB
HOOD OPENING.
MAINTENANCE:
1. REMOVE ALL ACCUMULATED SEDIMENT AND DEBRIS FROM SURFACE AND
VICINITY OF UNIT AFTER EACH STORM EVENT.
2. REMOVE THE SEDIMENT THAT HAS ACCUMULATED WITHIN THE FABRIC AS
NEEDED.
3. INSPECT WITHIN 24 HOURS OF A RAIN EVENT AND AT LEAST ONCE EVERY 7
CALENDAR DAYS.
DESIGN CONFORMS TO ALL
SHAPES OF CONCRETE CURBS
STANDARD FABRIC
ORANGE WOVEN
MONOFILAMENT
OVERFLOW GAP
CURB AND GUTTER
INLET
SCALE:
CURB AND GUTTER INLET PROTECTION
NONE
FL
O
W
PLAN
ELEVATION
FL
O
W
FL
O
W
SEE
NOTE 7
SEE NOTE 5
18" MINIMUM
POST AND FABRIC
EMBEDMENT
POST TIEBACK
8" MINIMUM
4"
FLOW FLOW
NOTES:
1. SYNTHETIC FILTER FABRIC SHALL BE A PERVIOUS SHEET OF WOVEN OR NON-WOVEN
GEOTEXTILE FABRIC AND SHALL BE CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS
CONFORMING TO THE FOLLOWING REQUIREMENTS:
a. TEXTILE STRENGTH AT 20% (MAXIMUM) ELONGATION, PER ASTM D4632.
b. WOVEN EXTRA STRENGTH - 50 LB/LINEAR INCH (MINIMUM), NON-WOVEN EXTRA
STRENGTH - 70 LB/INCH (MINIMUM).
c. WOVEN STANDARD STRENGTH - 30 LB/LINEAR INCH (MINIMUM), NON-WOVEN STANDARD
STRENGTH - 50 LB/INCH (MINIMUM).
d. APPARENT OPENING SIZE (AOS) (U.S. SIEVE) - NO. 30 PARTICLE SIZE OF 0.6 mm
(MAXIMUM), ASTM D4751.
e. PERMITTIVITY - 0.05 S-1 (MAXIMUM), ASTM D4491.
2. POSTS FOR SILT FENCES SHALL BE EITHER 2"X2" SQUARE WOOD OR EQUIVALENT METAL
POSTS WITH A MINIMUM LENGTH OF 5'. METAL POSTS SHALL HAVE PROJECTIONS FOR
FASTENING WIRE TO THEM.
3. ANCHOR STAKES FOR SILT FENCES SHALL BE 1"x2" WOOD (PREFERRED) OR EQUIVALENT
METAL WITH A MINIMUM LENGTH OF 18".
4. WIRE FENCE REINFORCEMENT FOR SILT FENCES USING STANDARD STRENGTH FILTER
CLOTH SHALL BE A MINIMUM OF 42" IN HEIGHT, A MINIMUM OF 14 GAUGE, AND SHALL HAVE
A MAXIMUM MESH SPACING OF 6".
5. THE HEIGHT OF THE BARRIER SHALL BE A MINIMUM OF 18" AND A MAXIMUM OF 30".
6. THE FABRIC SHALL BE PURCHASED IN A CONTINUOUS ROLL CUT TO THE LENGTH OF THE
BARRIER TO AVOID THE USE OF JOINTS. WHEN JOINTS ARE NECESSARY, FILTER FABRIC
SHALL BE SPLICED TOGETHER ONLY AT A SUPPORT POST, WITH A MINIMUM 6" OVERLAP,
AND SECURELY SEALED.
7. POSTS SHALL BE SPACED A MAXIMUM OF 6' APART AT THE BARRIER LOCATION AND DRIVEN
SECURELY INTO THE GROUND (MINIMUM OF 18"). WHEN STANDARD STRENGTH FABRIC IS
USED WITH THE WIRE SUPPORT FENCE, POST SPACING SHALL NOT EXCEED 8'.
8. THE SPACING OF TIEBACKS SHALL EQUAL THE SPACING OF THE POSTS. ADDITIONAL POST
DEPTH OR TIEBACKS MAY BE REQUIRED IN UNSTABLE SOILS.
9. A TRENCH SHALL BE EXCAVATED APPROXIMATELY 4" WIDE AND A MINIMUM OF 8" DEEP
ALONG THE LINE OF POSTS AND UPSLOPE FROM THE BARRIER.
10. WHEN STANDARD STRENGTH FILTER FABRIC IS USED WITH A WIRE MESH SUPPORT FENCE
IT SHALL BE FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS USING HEAVY
DUTY 1" WIRE STAPLES, TIE WIRES OR HOG RINGS. THE WIRE SHALL EXTEND INTO THE
TRENCH A MINIMUM OF 2" AND SHALL NOT EXTEND MORE THAN 36" ABOVE THE ORIGINAL
GROUND SURFACE.
11. THE STANDARD STRENGTH FILTER FABRIC, WITHOUT A WIRE MESH SUPPORT FENCE,
SHALL BE STAPLED OR WIRED TO THE FENCE, AND A MINIMUM 8" OF THE FABRIC SHALL BE
EXTENDED INTO THE TRENCH. THE FABRIC SHALL NOT EXTEND MORE THAN 36" ABOVE
THE ORIGINAL GROUND SURFACE. DO NOT STAPLE FILTER FABRIC TO EXISTING TREES.
12. WHEN EXTRA STRENGTH FILTER FABRIC OR BURLAP AND POST SPACING IS LESS THAN
THE MAXIMUM SPECIFIED SPACING OF 6', THE WIRE MESH SUPPORT FENCE MAY BE
ELIMINATED.
13. BACKFILL THE TRENCH AND COMPACT THE SOIL OVER THE FILTER FABRIC.
14. REMOVE SILT FENCES WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT
BEFORE THE UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED.
15. SILT FENCE SHALL NOT BE USED AS A DIVERSION AND SHALL NOT BE INSTALLED ACROSS
A STREAM, CHANNEL, DITCH, SWALE, ETC.
MAINTENANCE:
1. INSPECT AFTER EACH RAINFALL AND DAILY DURING PROLONGED RAINFALL. INSPECT AT
LEAST ONCE EVERY 7 CALENDAR DAYS.
2. REPLACE OR REPAIR FABRIC IMMEDIATELY IF IT DECOMPOSES OR IS INEFFECTIVE.
3. SEDIMENT DEPOSITS SHOULD BE REMOVED AFTER EACH STORM EVENT. THEY MUST BE
REMOVED WHEN DEPOSITS REACH APPROXIMATELY HALF THE HEIGHT OF THE BARRIER.
4. SPREAD ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE IS NO
LONGER REQUIRED AND DRESS TO CONFORM WITH THE FINISHED GRADING.
18" MINIMUM
MINIMUM 8" TRENCH
(UPSLOPE), BACKFILL
OVER SILT FENCE
GRADE AS
PER PLANS
METAL OR
WOOD POSTS
FILTER
FABRIC
TIEBACK
STAPLE OR FASTEN
FABRIC TO POSTS
ANCHOR STAKE
18" MINIMUM LENGTH
TIEBACK BETWEEN
FENCE POST AND
ANCHOR
FABRIC
EMBEDMENT TRENCH
WITH COMPACTED
SOIL BACKFILL
GEOTEXTILE FABRIC,
EXTEND FULL DEPTH
INTO TRENCH AND
ACROSS BOTTOM
SCALE:
SILT FENCE
NONE
SEASONAL SOIL PROTECTION CHART
DECNOVOCTSEPAUGJULJUNMAYAPRMARFEBJAN
A
B
C D E
F
G
B
STABILIZATION
PRACTICE
PERMANENT
SEEDING
DORMANT
SEEDING
TEMPORARY
SEEDING
SODDING
MULCHING
E
NOTES:
1. IRRIGATION NEEDED DURING MAY THROUGH SEPTEMBER.
2. IRRIGATION NEEDED FOR 2 TO 3 WEEKS AFTER APPLYING SOD.
3. ANCHORED MULCH IS REQUIRED FOR PERMANENT, DORMANT AND TEMPORARY SEEDING.
4. OPTIMUM SEEDING DATES PROVIDED. DATES MAY BE EXTENDED OR SHORTENED BASED ON PROJECT
LOCATION.
5. SEED MIXTURES PROVIDED FOR LAWNS AND HIGH MAINTENANCE AREAS.
6. IF CONSTRUCTION ACTIVITIES ARE LOCATED WITHIN A FLOODWAY, SEE MIXTURES CONSISTING OF TALL
FESCUE SHALL NOT BE UTILIZED.
MAINTENANCE:
1. INSPECT WITHIN 24 HOURS OF EACH RAIN EVENT AND AT LEAST ONCE EVERY 7 CALENDAR DAYS.
2. CHECK FOR EROSION AND MOVEMENT OF MULCH AND REPAIR IMMEDIATELY.
3. MONITOR FOR EROSION DAMAGE AND ADEQUATE COVER (70% DENSITY).
4. RESEED OR APPLY MULCH WHERE NECESSARY.
5. SELECT SOIL AMENDMENT MATERIALS AND RATES AS DETERMINED BY SOIL TESTS AND SITE
CONDITIONS.
A. = KENTUCKY BLUEGRASS 140 LB/ACRE; OR 170 LB/ACRE TALL FESCUE PLUS 30 LB/ACRE BLUEGRASS; OR
APPROVED EQUAL GRASS SEED MIXTURE
B. = KENTUCKY BLUEGRASS 210 LB/ACRE; OR 90 LB/ACRE PERENNIAL RYEGRASS PLUS 135 LB/ACRE BLUEGRASS OR 250 LB/ACRE TALL FESCUE (TURF TYP) PLUS 45 LB/ACRE BLUEGRASS; OR APPROVED
EQUAL GRASS SEED MIXTURE
C. = SPRING OATS 100 LB/ACRE (1" PLANTING DEPTH)
D. = WHEAT OR RYE 150 LB/ACRE (1" - 1.5" PLANTING DEPTH)
E. = ANNUAL RYEGRASS 40 LB/ACRE (1/4" PLANTING DEPTH)
F. = SOD
G. = ANCHORED STRAW/HAY (2 TONS/ACRE) OR WOOD FIBER/CELLULOSE (1 TON/ACRE) IS REQUIRED WITH
PERMANENT SEEDING AND TEMPORARY SEEDING. ALSO REQUIRED WITH DORMANT SEEDING UNLESS
SOIL IS IN FREEZE/THAW CYCLE.
PROFILE
PLAN
NOTES:
1. INSTALL SILT FENCE PRIOR TO ANY EXCAVATION.
2. FILTER WATER FROM BORE PIT DEWATERING, AND DO NOT DIRECTLY DISCHARGE TO ANY DITCH, STREAM, WETLAND OR STORM WATER CONVEYANCE. REFER TO PUMPING BAG DETAIL.
3. PLACE SOIL STOCKPILES WITHIN THE SILT FENCE BOUNDARY.
4. SOIL FROM STOCKPILES SHALL BE USED FOR BACKFILL OR DISPOSED OF PROPERLY.
5. RESEED AND MULCH ALL DISTURBED SOIL SURFACES.
6. ENVIRONMENTAL PROTECTION TO BE PROVIDED AS NECESSARY TO CONTAIN ANY DRILLING
FLUID SPILLS.
MAINTENANCE:
1. INSPECT SILT FENCE BARRIERS AFTER EACH RAINFALL, AND REPAIR OR REPLACE IMMEDIATELY.
2. REMOVE SEDIMENT DEPOSITS FROM THE SILT FENCE AFTER STORM EVENTS.
SOIL
STOCKPILE
SOIL
STOCKPILE
DRILL ENTRY PIT
DRILLING
RIG
SILT FENCE SILT FENCE
WORKING
AREA
DRILL EXIT PIT
ROAD/RAILWAY/WATERCOURSE
OR OTHER SURFACE OBSTRUCTION
SILT FENCE
SILT FENCE
SILT FENCE
SILT FENCE
DRILL EXIT PIT
HORIZONTAL
DIRECTIONAL
DRILLING RIG
DRILL ENTRY PIT
SCALE:
HORIZONTAL DIRECTIONAL DRILL
NONE
| 01 TITLE SHEET |
| 02 LOCATION PLAN AND DRAWING INDEX |
| 03 ABBREVIATIONS AND GENERAL NOTES |
| 04 PLAN AND PROFILE - LINE A |
| 05 PLAN AND PROFILE - LINE A |
| 06 PLAN AND PROFILE - LINE A |
| 07 PLAN AND PROFILE - LINE A |
| 08 PLAN AND PROFILE - LINE A |
| 09 PLAN AND PROFILE - LINE A |
| 10 MISCELLANEOUS DETAILS |
| 11 MISCELLANEOUS DETAILS |
| 12 EROSION CONTROL DETAILS |