2023-05-15_COT_City_Hall_Elevator_Replacement_-_Construction_Drawings.pdf
PDF 6 MB Posted
- Attached to
- City Hall - Elevator Modernization
- Solicitation number
- 240093
- Issued by
- Pima County, Tucson City, Arizona
About this file
This document is a set of architectural and engineering construction documents for the City of Tucson City Hall Elevator Improvements project located at 255 W Alameda St, Tucson, AZ 85701. The project involves the removal and replacement of two south-side elevators serving the City Hall building, which currently serve the basement level and all 10 floors. The improvements include new lighting, switching, heat sensors, and smoke detectors in the elevator shaft, as well as replacement of existing light fixtures in the penthouse machine room. The construction documents are dated May 12, 2023, with BWS Architects as the design firm and Monrad Engineering providing electrical and fire alarm consulting.
The project is designed to meet multiple building codes, including the 2018 International Building Code, 2017 National Electric Code, and 2010 ADA Standards for Accessible Design. The building is classified as a Type III-B Business Occupancy with full sprinkler protection. The elevator improvement documents include detailed floor plans for the basement, first floor, penthouse, and machine room levels, as well as electrical demolition and new electrical plans. The project scope references a request for proposal from Lerch Bates dated October 28, 2022, and involves comprehensive modifications to the existing elevator infrastructure while maintaining the building's current operational capabilities.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OWNER CONSULTANTS
261 North Court Avenue
Tucson, Arizona 85701
520.795.2705 www.bwsarchs.com bws ARCHITECTS
CITY OF TUCSON
CITY OF TUCSON
CITY HALL ELEVATOR
IMPROVEMENTS
2220.000
May 12, 2023
CONSTRUCTION DOCUMENTS
C O
N S T R
U C
T
IO
N D
O C
U M
E N
T S
M ay
2, C
IT
Y H
A
LL
E
LE
V A
T O
R I
M P
R O
V E M
E N
T S
B W
S P ro je ct N o.
.0
255 W Alameda St, Tucson, AZ 85701
C
IT
Y O
F
TU
C S
O N
Monrad Engineering
1926 E Fort Lowell Rd
Tucson, AZ 85719
Phone: 520-884-0045
ELECTRICAL/FIRE ALARM
BWS PROJECT NUMBER
MECHANICAL
PENTHOUSE
Carlos Carrazco; Project Manager
A&E Division / Facilities Maintenance
Environmental and General Services Dept.
P.O. Box 27210
Phone: 520-955-1098
PENTHOUSE
MACHINE
ROOM
ELEV.
SHAFT
ELEV.
PIT
BASEMENT
MACHINE
ROOM
JROSS
Snapshot
JROSS
Text Box 1 7
MATCH LINE
IDENTIFYING REVISION
CODE DESIGNATION
CLOUD ENCLOSES
REVISION
ELEVATION INDICATOR
REVISION CLOUD
KEYNOTE TAG
WALL TYPE
MATCH LINE
SHEET WHERE DRAWN
DOOR NUMBER
DOOR MARK
ROOM NUMBER
ELEVATION REFERENCE NO.
SHEET WHERE DRAWN
DETAIL NUMBER
DRAWING NUMBER
SHEET WHERE DRAWN
SHEET WHERE DRAWN
SECTION NUMBER
ROOM NAME AND NUMBER
WINDOW MARK
DOOR MARK
EXTERIOR ELEVATION
INTERIOR ELEVATION
DETAIL MARK
ENLARGED AREA OR
WALL SECTION
SECTION LETTER
BUILDING SECTION
COLUMN GRID
16'- 0" A.F.F.
FF ELEV
A101
SIM
A101
SIM
View Name
SCALE: 1/8" = 1'-0"
/1 A101
/1 A101
1t
ROOM NAME
A6.1
A5.1
A1
1 1
A101
SIM
RIGHT OF WAYROW
EW EACH WAY
JT
JST
JOINT
JOIST
LLH LONG LEG HORIZONTAL
LIGHTWEIGHT
LOW POINT
LONG LEG VERTICAL
LT
LVR
LTWT
LP
LLV
LIGHT
LOUVER
LABORATORY
LINEAL FEET
KNOCK OUT
KICK PLATE
LENGTH, LONG
KNOCKED DOWN
LEFT HAND
LAB
LF
LAV
LAM
L
LH
LL
LAVATORY
LAMINATE
LIVE LOAD
KIT
KO
KD
KP
KITCHEN
GALV GALVANIZED
HP HIGH POINT
HEATING/VENTILATING/
INSULATED COMPOSITE
INSIDE DIAMETER
INCLUDING
INVERT ELEVATION
INSULATION
AIR CONDITIONING
HOT WATER
METAL WALL PANEL
JANITORS CLOSET
ID
IE
IN
INCL
INT
INSUL
JC
INCH(ES)
INTERIOR
HR
HVAC
HW
ICMWP
HOUR
HOSE BIBB
HOLLOW CORE
HARDBOARD
HARDWOOD
HARDWARE
HEAVY DUTY
GENERAL CONTRACT(OR)
GLASS, GLAZING
GYPSUM WALLBOARD
HORIZONTAL
HOLLOW METAL
HIGH IMPACT WOOD FIBER PANEL
H(T) HEIGHT
HDWD
HDWR
HB
HC
HDBD
HD
HORZ
HM
GC
GD
GL
GYP
GWB
HIW
GYPSUM
GRADE
FF FINISH FLOOR
FIBER REINFORCED PLASTIC
FIREPROOF
FOOT,FEET
FIRE RETARDANT
FURRED(ING)
FLUORESCENT
GAGE,(GUAGE)
FT
FTG
FUR
FUT
GA
FOOTING
FUTURE
FO
FP
FLUOR
FIN
FLA
FLEX
FRP
FR
FACE OF
FLASHING
FLEXIBLE
FINSH(ED)
EXTERIOR FINISH SYSTEM
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FABRICATE
EXPANSION
FAHRENHEIT
FIRE ALARM
ELECTRIC WATER COOLER
EXCAVAT(E)(ION)
FIRE EXTINGUISHER(CABINET)
EXT. INSULATION FINISH SYSTEM
FD
FE
FDN
F
FA
FAB
FEC
EXIST
EXH
EXP
EXT
EWC
EXC
EFS
EIFS
EXHAUST
EXISTING
EXTERIOR
VINYL WALL COVERINGVWC
WAINSCOTWSCT
WELDED WIRE FABRIC
YD
WT
WWF
YARD
WEIGHT
WIDTH, WIDE, WEST
WATERPROOFING
WATER REPELLENT
WALL HUNG, WATER HEATER
WOODWD
WH
WM
WP
WI
WDW
WR
WS
WIRE MESH
WINDOW
WROUGHT IRON
WEATHERSTRIP
W/ W/O
W
W/W
WC
WITHOUT
WITH
WALL TO WALL
WATER CLOSET
SYMMETRY(ICAL)SYM
TOP OF WALLTOW
TOILET PAPER DISPENSER
VINYL COMPOSITION TILE
UNLESS NOTED OTHERWISE
VENEER PLASTER
UNDERWRITERS LABORATORY
UNFINISHEDUNF
UNO
VB
VCT
VNR
VPL
VERT
VAPOR BARRIER
VENEER
VERTICAL
TPD
TV
TYP
U
UL
UG
TYPICAL
TELEVISION
URINAL
UNDERGROUND
THICKNESS, TEE
TONGUE AND GROOVE
TOP OF MASONRY
TOP OF CONCRETE
TOP OF PARAPET
TEMPERATURE, TEMPORARYTEMP
TERR
THK
TO
TOIL
TOM
TOC
TOS
TOP
TERRAZZO
THICK(NESS)
TOP OF
TOILET
TOP OF STEEL
T
T&G
TB
TD
TEL
TACKBOARD
TRENCH DRAIN
TELEPHONE
SHEET METALSM
SPECIFICATIONS
SEAMLESS VINYL
STAINLESS STEEL
SOUND TRANSMISSION COEFFICIENTSTC
STRUC
SV
SW
STD
STOR
SUSP
SWR
SWITCH
STANDARD
STORAGE
SUSPENDED
STRUCTURAL
SEWER
SQ
SS
SPECS
SP
SPKR
SPL
ST
SST
SQUARE
SPECIAL
SPEAKER
SERVICE SINK
SOUNDPROOF
STEEL, STREET
RAINWATER LEADER
SURFACE MOUNTED
SCHEDULESCHED
SF
SHWR
SHEET
SD
SDG
SECT
SIM
SHOWER
SHEET
SECTION
SIDING
SQUARE FEET
STORM DRAIN
SIMILAR
RWL
S (S)
REQ'D
SC
REQUIRED
SEALED, SOUTH
SOLID CORE
BRG BEARING
CPT CARPET
DS DOWNSPOUT
ELEVATION, ELEVATOR
DRYWALL CHANNELS (HAT)
EPOXY PAINT
EMERGENCY
EQUIPMENT
EXPOSED STRUCTURE
EACH FACE
EXPANSION JOINT
ELECTRIC(AL)ELEC
EQUIP
EP
EQ
EMER
ES
ELEV
EST
EQUAL
ESTIMATE
DWG
DWC
DTL
EA
EF
E
EJ
DRAWING
DETAIL
EACH
EAST
DEMOLISH, DEMOLITION
DRINKING FOUNTAIN
DISPENSER
DIMENSION
DAMPPROOFING
COUNTERSINK
COLD WATER
CUBIC FOOT (FEET)
CERAMIC TILE
DIA
DF
DIAMETER
DN
DIAG
DIM
DISP
DO
DP
DR
DIAGONAL
DOWN
DITTO
DOOR
CT
CU FT
CW
CU
CSK
D
DEMO
CUBIC
DEPTH
CG CORNER GUARD
CORRIDOR,CORRUGATED
CONTINUOUS OR CONTINUE
CORRUGATED METAL PIPE
CONCRETE MASONRY UNIT
COMMENTS
CONSTRUCTION
CONNECTION
CONCRETE
CLEAN OUT
COMBINATION
CAST IRON
CONTROL JOINT
CLEAR(ANCE)
CAST IN PLACE
CO
CORR
CONST
CONT
CONN
COMB
CONC
COL COLUMN
CMTS
CMU
CI
CJ
CLG
CLR
CIP
CMP
CEILING
CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CONTRACTOR FURNISHED,
CHALK BOARD,CATCH BASIN
OWNWER INSTALLED
COMPOSITE METAL
CENTER TO CENTER
WALL PANEL
BASEMENT
BUILT UP ROOFING
C/C
CFOI
CAB
CEM
CFCI
CB
CABINET
CEMENT
CMWP
C
BRK
BSMT
BUR
CHANNEL
BRICK
AC ACOUSTICAL CEILING
BLOCK(ING)
BENCH MARK
BOTTOM OF
ALUMINUM
AGGREGATE
ALTERNATE
BELOW FINISH FLOOR
ANCHOR, ANCHORAGE
ABOVE FINISH FLOOR
BLDG
BLK(G)
BM
BO
BOT
BFF
BD
BUILDING
BOTTOM
BOARD
AGG
ALT
ALUM
ANOD
ANCH
ADJ
AFF
ANODIZED
ADJACENT
AGGREGATE BASE COURSE
AIR CONDITIONING
ANCHOR BOLT
A/C
ABC
AB
AT
NOM NOMINAL
PO POWER OPERATED
RECESSED(R)
REFLECTED CEILING PLAN
RADIUS, RISER ROUND
REVISION(S), REVISED
RIGID FIBERGLASS
REINFORCED CONCRETE PIPE,
ROUGH OPENING
RELOCATIONRELO
RES
REV
RF
RH
RM
RFG
REPL
RO
RESILIENT
RIGHT HAND
ROOFING
ROOM
REPLACE
RA
RB
RCP
R
RD
RE(F)
RETURN AIR
ROOF DRAIN
REFERENCE
RESILIENT BASE
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PAPER TOWEL DISPENSER
PAPER TOWEL RECEPTOR
POLYVINYL CHLORIDE
PLYWOOD
PAVEMENT
PWD
PVMT
QT
QTR
QTY
QUARTER
QUANTITY
QUARRY TILE
PR
PSF
PSI
PT
PTD
PTR
PVC
PAIR
POINT
PAINT(ED)P
POUNDS PER CUBIC FOOT
PARTICLE BOARD
PRECAST CONCRETE
POUNDS PER LINEAL FOOT
PERPENDICULAR
PREFABRICATED
PLASTIC LAMINATE
PLASTER, PLATE, PROPERTY LINE
PERP
PNL
PJ
PL
PLBG
PF
PLF
PLAM
PANEL
PANEL JOINT
PLUMBING
PART BD
PREFAB
PERIM
PAR
PC
PCC
PART
PCF
PERIMETER
PARALLEL
PARTITION
PIECE
PERFORATE(D)
OUTSIDE DIAMETER
OVERFLOW ROOF DRAIN
NOISE REDUCTION COEFFICIENTS
OVERHEAD, OPPOSITE HAND
OWNER FURNISHED CONTRACTOR INSTALLED
OWNER FURNISHED OWNER INSTALLED
OFCI
ORD
OFF
OH
OPG
OPP
OFOI
OPENING
OPPOSITE
OFFICE
OA
OC
OD
NRC
NTS
NO
OVERALL
NUMBER
ON CENTER(S)
NOT TO SCALE
MECHANICALMECH
MANUFACTURER
MASONRY OPENING
NOT IN CONTRACT, (OFOI)
NOT APPLICABLE
METAL WALL PANEL (SYSTEM)
MODULARMOD
N
NA
NIC
MWP
MTD
MOV
NORTH
MOUNTED
MOVABLE
MFR
MH
MIN
MO
MISC
MET
MEZZ
MINIMUM
MANHOLE
MEZZANINE
METAL
MISCELLANOUS
MAS
MAX
MED
MATL
MASONRY
MAXIMUM
MATERIAL
MEDIUM
ARCHITECTURALLY EXPOSED STRUCTURAL
STEEL
AESS
GENERAL NOTES:
A. TO THE BEST OF OUR KNOWLEDGE AND INFORMATION AND IN ACCORDANCE WITH
ACCEPTED PROFESSIONAL STANDARDS, WE HAVE COMPLIED WITH APPLICABLE
PORTIONS OF THE AMERICAN WITH DISABILITIES ACT PERTAINING TO BUILDING
ACCESSIBILITY FOR THE PHYSICALLY HANDICAPPED.
B. ALL DIMENSIONS GIVEN TO FACE OF MASONRY/CONCRETE, AND GYPSUM BOARD
AND METAL STUD CONSTRUCTION. EXCEPTIONS AS INDICATED ON DRAWINGS.
C. DRAWINGS SHALL NOT BE SCALED. ALL WORK SHALL BE LAID OUT BY DIMENSIONS
NOTED ON THE DRAWINGS.
D. CONTRACTOR IS RESPONSIBLE FOR CONSTRUCTION OF ALL EQUIPMENT PADS
REQUIRED BY EQUIPMENT MANUFACTURER. ACTUAL SIZE AND LOCATION TO BE
COORDINATED WHT APPROVED EQUIPMENT MANUFACTURER.
E. HVAC AND ELECTRICAL EQUIPMENT SHOWN ON ARCHITECTURAL DRAWINGS IS FOR
GENERAL REFERENCE ONLY. COORDINATE EQUIPMENT AND LOCATIONS WITH
MECHANICAL AND ELECTRICAL DRAWINGS.
F. FIRE RATINGS SHALL BE MAINTAINED AT FIRE RATED PARTITIONS BY PROVIDING FIRE
SAFING MATERIAL AT GAPS AND VOIDS CREATED BY PENETRATIONS, STRUCTURAL
MEMBERS, AND INTERSECTIONS WITH ADJACENT SURFACES AS REQUIRED. REFER TO
FIRE PROTECTION LISTINGS FOR SPECIFIC ASSEMBLIES.
G. ALL DETAILS APPLY WHETHER OR NOT SPECIFICALLY REFERENCED.
H. ITEM LOCATED IN CEILING TILES ARE TO BE CENTERED AT THE MIDPOINT OF EACH
TILE, TYPICAL. WHERE TWO ITEMS OCCUR, LOCATE AT THIRD POINTS, THREE ITEMS
TO BE LOCATED AT QUARTER POINTS.
APPLICABLE CODES:
APPLICABLE CODES & CODE INFORMATION CAN BE FOUND ON THE REMAINING "G" SHEETS
AS LISTED IN THE SHEET INDEX.
1. FIRE SPRINKLERS MODIFICATIONS
2. FIRE ALARM MODIFICATIONS
1.
2.
3.
4.
5.
TUCSON
CITY HALL
i-1
CONGRESS ST.
ST. MARY'S ROAD
6TH STREET
W. ALAMEDA ST.
N . G
R A
N A
D A
A
VE 255 W. ALAMEDA ST.
Applicable Codes:
2018 International Building Code (IBC)
2018 International Mechanical Code (IMC)
2018 International Fuel Gas Code (IFGC)
2018 International Plumbing Code (IPC)
2018 International Energy Conservation Code (IECC)
2017 National Electric Code (NEC)
2010 ADA Standards for Accessible Design (ADA)
1998 ICC/ANSI A117.1 (ANSI)
NFPA (In Total)
Arizona Revised Statutes, Title 34,Chapter 4
- 34-401 Energy Conservation Standards
- 34-452 Solar Design Standards Energy Life Cycle Costing
City of Tucson Zoning: Not applicable - Interior Work Only
Project Description: This project consists of the removal and replacement of the (2) South-side Elevators serving the City Hall building. These elevator cabs serve the basement level and all 10 floors of the building. Implementation of this replacement requires new lighting, switching, heat sensors and smoke detectors in the elevator shaft, as well as replacement of existing light fixtures in the penthoues machine room above.
Occupancy Classification (Section 302): (B) Business Occupancy
Fire Protection (Chapter 9): Full Sprinklered
Type of Construction (Tables 504.3, 504.4): Type III-B
BUILDING CODE REVIEW
Exit and Occupant Loads (Table 1004.5): Refer to Code Plans
Classroom 20 SF / Occupant
Business Offices 150 SF / Occupant
Assembly w/o Fixed Seats
Chairs Only 7 SF / Occupant
Table and Chairs 15 SF / Occupant
Library - Reading Room 50 SF / Occupant
Accessory St./Mech./Eq. Rm. 300 SF / Occupant
Width of Exits (Table 1005): Fully Sprinklered
Doors and Hallways Occupant Load x .15” / Occupant
Stairways Occupant Load x .20” / Occupant
1019.3 Exit access stairways.
Occupancies other than Groups I-2 and I-3. In other than Group I-2 and I-3 occupancies, floor openings containing xit access stairways or ramps that do not comply with one of the conditions listed in this section shall be enclosed with a shaft enclosure constructed in accordance with Section 713.
1. Exit access stairways and ramps that serve or atmospherically communicate between only two stories. Such interconnected stories shall not be open to other stories.
Distance to Exits (Table 1017.2): with Fire Sprinklers
Group E 250 FT
Group B 300 FT
Number of Exits (Table 1006.3.2):
All rooms and spaces within each story shall be provided with and have access to the minimum number of approved independent exits required by section
1006 based on the occupant load.
Minimum 2 Exits or Exit Access Doorways required > 49 occupants in any A & B space
Minimum 2 Exits or Exit Access Doorways required when Common Path of Egress >75 feet
3 Exits required when occupant load exceeds 500
4 Exits required when occupant load exceeds 1,000
INDEX TO DRAWINGSABBREVIATIONS SYMBOLS PROJECT DATA
NO. SHEET NAME
GENERAL
CVR COVER
GENERAL
G1.1 INDEX, ABBREVIATIONS, SYMBOLS & PROJECT DATA
ARCHITECTURAL
A2.1 FLOOR PLANS - BASEMENT & FIRST FLOOR
A2.2 FLOOR PLANS - PENTHOUSE & MACHINE ROOM LEVEL
A5.1 BUILDING SECTIONS
ELECTRICAL
E2.1 ELECTRICAL FLOOR PLAN - BASEMENT & FIRST FLOOR
E2.2 ELECTRICAL FLOOR PLANS - PENTHOUSE & MACHINE ROOM LEVEL
VICINITY MAPAPPLICABLE CODES
DEFERRED SUBMITTALS
SPECIAL INSPECTIONS
R
EG
IST
ERED ARCHITECT
A
R I Z O N A , U . S
A
D a t e S ig n ed . . .
CE
RT
IFICATE NO.23533
ROBIN A.
SHAMBACH
EXPIRES 06/30/2025
-4004 S. Park Avenue, Bldg. 2
Tucson, AZ 85714
Tel: (520) 837-6375
Email:AE-Archivist@tucsonaz.gov
Environmental and General Services
Department
Sheet Title:
A&E Job No.:
A&E Plan No.:
Sheet:
Of______ ______
Date:
Revision:
Seal:
Architect:
bws ARCHITECTS
Project:
Architecture and
Engineering
City of Tucson
261 North Court Avenue
Tucson, Arizona 85701
520.795.2705 www.bwsarchs.com
5/15/23
C-23-005
P22015
G1.1
INDEX, ABBREVIATIONS, SYMBOLS &
PROJECT DATA
C
IT
Y O
F T
U C
S O
N C
IT
Y H
A
LL
E
LE
V A
TO
R
I M
P R
O V
E M
E N
TS
W A la m ed a
S t, Tu cs on , A
Z
May 12, 2023
*DRAWINGS ARE MEANT TO ACCOMPANY RFP FROM LERCH BATES DATED OCTOBER 28, 2022
JROSS
2 7
DOWN
J J
T
R A M P
D O W N
DOWN
DOWN
D O W N
G G
H H
K K
L L
M
M
F F
D D
E E
J J
N
N
TRANSFORMER VAULT
MEN'S
RR
WOMEN'S
RR
SWITCHBOARD
A5.1
A5.1
ELEVATOR
SHAFT
MECH
SHAFT
BASEMENT
LOBBY
A5.1
A5.1
F.
V
7'
11 11
12 12
13 13
F.V.
18' - 9"
MACHINE
ROOM
CORRIDOR
CORRIDOR
CHASE
(ENCLOSED)
CORRIDOR
EXIST. ELEV. SHAFT DOORS TO
REMAIN, TYP AT ALL LEVELS
F.V.
2' - 5"
F.V.
4' - 1"
F.V.
5' - 5"
F.V.
4' - 1"
F.V
3' - 3"
FIELD VERIFY ALL DIMENSIONS
EXIST.
MAIN SWITCHBOARDS
G
H
K
L
M
F
E
J
N
A5.1
A5.1
ELEVATOR
SHAFT
MECH
SHAFT
ELEVATOR
LOBBY (1ST)
A5.1
A5.1
EXIST.
FACP
BUILDING
LOBBY &
SECURITY
SECURITY CHECK
ELEVATOR CABINS
- EXIST. CABS (2) TO BE DISASSEMBLED IN-PLACE
& REMOVED FROM ELEV. SHAFT.
- REF. RFQ BY LERCH BATES FOR DETAILS & SCOPE
OF DEMO/NEW WORK RELATED TO ELEV.
- ASSUME NEW LVT FLOORING IN ELEV. CABS.
(FINAL COLOR SELECTION BY OWNER DURING
SUBMITTAL REVIEW)
EXIST. ELEV. SHAFT DOORS
TO REMAIN, TYP AT ALL
LEVELS
EXISTING BEAM TO REMAIN, F.V. LOCATION
NORTH PUBLIC ENTRY DOORS &
SECURITY CHECK - ALL PERSONS
AFFILIATED WITH THE PROJECT WILL
NEED TO CHECK IN DAILY.
A. DIMENSIONS ARE TO COLUMN CENTERLINE OR FACE OF WALL, U.N.O.
B. ALL WALLS ARE TO UNDERSIDE OF DECK, U.N.O.
C. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING
ELEMENTS AND DIMENSIONS ON THE PLANS PRIOR TO PREPARATION OF
SUBMITTAL DOCUMENTS.
ELEV. SHAFT
NORTH
PLAZA
TO W. ALAMEDA ST.
TO W. PENNINGTON ST.
ELEV. SHAFT
MACHINE
ROOM
R
EG
IST
ERED ARCHITECT
A
R I Z O N A , U . S
A
D a t e S ig n ed . . .
CE
RT
IFICATE NO.23533
ROBIN A.
SHAMBACH
EXPIRES 06/30/2025
-4004 S. Park Avenue, Bldg. 2
Tucson, AZ 85714
Tel: (520) 837-6375
Email:AE-Archivist@tucsonaz.gov
Environmental and General Services
Department
Sheet Title:
A&E Job No.:
A&E Plan No.:
Sheet:
Of______ ______
Date:
Revision:
Seal:
Architect:
bws ARCHITECTS
Project:
Architecture and
Engineering
City of Tucson
261 North Court Avenue
Tucson, Arizona 85701
520.795.2705 www.bwsarchs.com
5/15/23
C-23-005
P22015
A2.1
FLOOR PLANS - BASEMENT & FIRST
FLOOR
C
IT
Y O
F T
U C
S O
N C
IT
Y H
A
LL
E
LE
V A
TO
R
I M
P R
O V
E M
E N
TS
W A la m ed a
S t, Tu cs on , A
Z
May 12, 2023
1/8" = 1'-0"1
FLOOR PLAN - BASEMENT FLOOR 0' 4' 8' 16'
1/8" = 1'-0"2
FLOOR PLAN - FIRST FLOOR
FLOOR PLAN GENERAL NOTES
KEY PLAN | FIRST FLOOR
0' 4' 8' 16'
KEY PLAN | BASEMENT
JROSS
3 7
UPUP
A. DIMENSIONS ARE TO COLUMN CENTERLINE OR FACE OF WALL, U.N.O.
B. ALL WALLS ARE TO UNDERSIDE OF DECK, U.N.O.
C. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING
ELEMENTS AND DIMENSIONS ON THE PLANS PRIOR TO PREPARATION OF
SUBMITTAL DOCUMENTS.
G
H
K
L
M
P
F
E
J
N
A5.1
A5.1
A5.1
A5.1
ELEVATOR
SHAFT
COOLING
TOWER
P101
PENTHOUSE
LOBBY
P100
PENTHOUSE
MECHANICAL
ROOM
P102
NON-CONDITIONED
EXTERIOR SPACE
EXISTING PARAPET WALL
EXISTING PARAPET WALL
ROOFTOP AREA
ROOFTOP AREA
EXIST. ACCESS HATCH &
OVERHEAD HOIST CRANE
EXIST. SHIPS LADDER TO
MACHINE ROOM LEVEL ABOVE
EXISTING ROOFTOP ELECTRICAL
PANELS & EQUIPMENT
EQUIPMENT & DUCTING FROM THIS SPACE SERVES MACHINE
ROOM AT LEVEL ABOVE
MECHANICAL ENGINEER APPROVED EXISTING
COOLING/VENTILATION IS ACCEPTABLE TO REMAIN
ROOF OF ELEV. CABS BELOW
(NO EXIT AT THIS LEVEL)
CITY MAINTENANCE WORKSPACE
G
H
K
L
M
F
E
J
N
A5.1
A5.1
A5.1
A5.1
STEEL-FRAMED
SCAFFOLD STAIR
LANDING
309 SF
MACHINE
ROOM
P11
COOLING
TOWER
P101
PENTHOUSE
MECHANICAL
ROOM
P102
ACCESSIBLE FROM
PENTHOUSE LEVEL
REMOVE & REPLACE EXIST. MACHINE GEAR,
REF LERCH BATES' RFQ FOR REQUIREMENTS
STAIR WELL OPEN
TO BELOW
OPEN
TO
BELOW
DASHED LINE DENOTES NORTH FACE OF
ELEVATOR SHAFT BELOW
REFER TO ELECTRICAL FOR EXISTING
AND NEW EQUIPMENT IN THIS SPACE
EXIST. FLOOR OPENINGS BELOW GEAR
FIELD VERIFY OPENING SIZES & LOCATIONS
ELEV. SHAFT
ROOF ROOF
ELEV.
MACHINE
ROOM
ROOF
BELOW
ROOF
BELOW
FLOOR PLAN GENERAL NOTES
R
EG
IST
ERED ARCHITECT
A
R I Z O N A , U . S
A
D a t e S ig n ed . . .
CE
RT
IFICATE NO.23533
ROBIN A.
SHAMBACH
EXPIRES 06/30/2025
-4004 S. Park Avenue, Bldg. 2
Tucson, AZ 85714
Tel: (520) 837-6375
Email:AE-Archivist@tucsonaz.gov
Environmental and General Services
Department
Sheet Title:
A&E Job No.:
A&E Plan No.:
Sheet:
Of______ ______
Date:
Revision:
Seal:
Architect:
bws ARCHITECTS
Project:
Architecture and
Engineering
City of Tucson
261 North Court Avenue
Tucson, Arizona 85701
520.795.2705 www.bwsarchs.com
5/15/23
C-23-005
P22015
A2.2
FLOOR PLANS - PENTHOUSE & MACHINE
ROOM LEVEL
C
IT
Y O
F T
U C
S O
N C
IT
Y H
A
LL
E
LE
V A
TO
R
I M
P R
O V
E M
E N
TS
W A la m ed a
S t, Tu cs on , A
Z
May 12, 2023
0' 4' 8' 16'
1/8" = 1'-0"1
FLOOR PLAN - PENTHOUSE FLOOR
1/8" = 1'-0"2
FLOOR PLAN - MACHINE ROOM LEVEL
KEY PLAN | PENTHOUSE
0' 4' 8' 16'
KEY PLAN | MACHINE ROOM LEVEL
JROSS
4 7
FIRST FLOOR
0' - 0"
SECOND FLOOR
14' - 0"
THIRD FLOOR
26' - 3"
BASEMENT
-12' - 0"
FOURTH FLOOR
38' - 6"
TENTH FLOOR
112' - 0"
ELEVATOR PIT
-18' - 8"
PENTHOUSE LEVEL
124' - 2"
T.O.PENTHOUSE
140' - 6"
FL
O O
R S
2' -3
EA
C H
ELEVATOR
SHAFT
OVERHEAD HOIST BEAM
HOISTWAY CENTER BEAM,
TYP AT ALL FLOORS
MACHINE ROOM LEVEL
131' - 8"
COOLING
TOWER
P101
ELEVATOR
SHAFT
MACHINE
ROOM
P11
PENTHOUSE
LOBBY
P100
REMOVE & REPLACE EXIST. MACHINE GEAR,
REF LERCH BATES' RFQ FOR REQUIREMENTS
EXIST. FLOOR OPENINGS BELOW GEAR
FIELD VERIFY OPENING SIZES & LOCATIONS
FIRST FLOOR
0' - 0"
SECOND FLOOR
14' - 0"
THIRD FLOOR
26' - 3"
BASEMENT
-12' - 0"
FOURTH FLOOR
38' - 6"
TENTH FLOOR
112' - 0"
GHKLM F EJN
ELEVATOR PIT
-18' - 8"
PENTHOUSE LEVEL
124' - 2"
T.O.PENTHOUSE
140' - 6"
A5.1
ELEVATOR
SHAFT
BASEMENT
LOBBY
HOISTWAY OVERHEAD BEAM
EXIST. VENT LOUVERS TO REMAIN
PENTHOUSE
MECHANICAL
ROOM
P102
PENTHOUSE
LOBBY
P100
ELEVATOR
SHAFT
MACHINE ROOM LEVEL
131' - 8"
MACHINE
ROOM
P11
ELEVATOR PIT
ELEVATOR
LOBBY (1ST)
ELEVATOR
LOBBY
(2ND)
ELEVATOR
LOBBY
(3RD)
FL
O O
R S
2' -3
EA
C H
ELEVATOR MACHINE
HOIST BEAM, TYP AT ALL FLOOR LEVELS
EXIST. ELEV. SHAFT DOORS TO REMAIN, TYP
R
EG
IST
ERED ARCHITECT
A
R I Z O N A , U . S
A
D a t e S ig n ed . . .
CE
RT
IFICATE NO.23533
ROBIN A.
SHAMBACH
EXPIRES 06/30/2025
-4004 S. Park Avenue, Bldg. 2
Tucson, AZ 85714
Tel: (520) 837-6375
Email:AE-Archivist@tucsonaz.gov
Environmental and General Services
Department
Sheet Title:
A&E Job No.:
A&E Plan No.:
Sheet:
Of______ ______
Date:
Revision:
Seal:
Architect:
bws ARCHITECTS
Project:
Architecture and
Engineering
City of Tucson
261 North Court Avenue
Tucson, Arizona 85701
520.795.2705 www.bwsarchs.com
5/15/23
C-23-005
P22015
A5.1
BUILDING SECTIONS
C
IT
Y O
F T
U C
S O
N C
IT
Y H
A
LL
E
LE
V A
TO
R
I M
P R
O V
E M
E N
TS
W A la m ed a
S t, Tu cs on , A
Z
May 12, 2023
1/8" = 1'-0"1
BUILDING SECTION - ELEVATOR SHAFT & PENTHOUSE (LOOKING NORTH)
1/8" = 1'-0"2
BUILDING SECTION - ELEVATOR SHAFT & PENTHOUSE (LOOKING WEST)
JROSS
5 7
MEN'S
RR
WOMEN'S
RR
ELE9ATOR
SHA)T
MECH
SHA)T
%ASEMENT
LO%%<
CORRIDOR
CHASE
(ENCLOSED)
MEN'S
RR
WOMEN'S
RR
ELE9ATOR
SHA)T
MECH
SHA)T
%ASEMENT
LO%%<
CORRIDOR
CHASE
(ENCLOSED)
ELEV. SHAFT
MACHINE
ROOM
-4004 S. Park Avenue, Bldg. 2 Tucson, AZ 85714 Tel: (520) 837-6375 Email:AE-Archivist@tucsonaz.gov
Environmental and General Services Department
Sheet Title:
A&E Job No.:
A&E Plan No.:
Sheet:
Of______ ______
Date:
Revision:
Seal:
Architect:
bws $5&+,7(&76
Project:
Architecture and
Engineering
City of Tucson
261 North Court Avenue Tucson, Arizona 85701 520.795.2705 www.bwsarchs.com
CI
TY
O F
TU
CS
ON
CI
TY
H
AL
L
EL
EV
AT
OR
IM
PR
OV
EM
EN
TS
W A la m ed a
St , T uc so n, A
Z
May 12, 2023
ENGINEERING
CONSULTING ELECTRICAL ENGINEERS
INC
1926 East Ft. Lowell Road, Suite 200 Tucson, Arizona 85719-2391
(520) 884-0045
LOCKOUT - TAGOUT - TESTOUT
C-23-005
P22015
E2.1
ELECTRICAL FLOOR PLAN -
BASEMENT & 1ST FLOOR
SCALE: 1/4''=1'-0'' SCALE: 1/4"=1'-0''
KEY PLAN | BASEMENT
c a d se rv e r2 C A D D D a ta p ro je c ts
C O T C it y H a ll E le v\ E .1 .d w g
:5 :4
A M
JROSS
6 7
UP
STEEL-FRAMED
SCAFFOLD STAIR
LANDING
ACCESSIBLE FROM
PENTHOUSE LEVEL
EXIST. ELEVATOR MACHINES
EXIST. FLOOR OPENINGS BELOW EACH
FIELD VERIFY OPENING SIZES & LOCATIONS
STAIR WELL OPEN
TO BELOW
OPEN
TO
BELOW
DASHED LINE DENOTES NORTH FACE OF
UP
ELEVATOR
SHAFT
PENTHOUSE
LOBBY
NO ELEVATOR ACCESS AT PENTHOUSE LEVEL
OVERHEAD HOIST AREA ONLY
NON-CONDITIONED
EXTERIOR SPACE
EXISTING PARAPET WALL EXIST. ACCESS HATCH &
OVERHEAD HOIST CRANE
UP
STEEL-FRAMED
SCAFFOLD STAIR
LANDING
ACCESSIBLE FROM
PENTHOUSE LEVEL
EXIST. ELEVATOR MACHINES
EXIST. FLOOR OPENINGS BELOW EACH
FIELD VERIFY OPENING SIZES & LOCATIONS
STAIR WELL OPEN
TO BELOW
OPEN
TO
BELOW
DASHED LINE DENOTES NORTH FACE OF
UP
ELEVATOR
SHAFT
PENTHOUSE
LOBBY
NO ELEVATOR ACCESS AT PENTHOUSE LEVEL
OVERHEAD HOIST AREA ONLY
NON-CONDITIONED
EXTERIOR SPACE
EXISTING PARAPET WALL EXIST. ACCESS HATCH &
OVERHEAD HOIST CRANE
ELEV. SHAFT
ROOF ROOF
ELEV.
MACHINE
ROOM
ROOF
BELOW
ROOF
BELOW
-4004 S. Park Avenue, Bldg. 2 Tucson, AZ 85714 Tel: (520) 837-6375 Email:AE-Archivist@tucsonaz.gov
Environmental and General Services Department
Sheet Title:
A&E Job No.:
A&E Plan No.:
Sheet:
Of______ ______
Date:
Revision:
Seal:
Architect:
bws $5&+,7(&76
Project:
Architecture and
Engineering
City of Tucson
261 North Court Avenue Tucson, Arizona 85701 520.795.2705 www.bwsarchs.com
CI
TY
O F
TU
CS
ON
CI
TY
H
AL
L
EL
EV
AT
OR
IM
PR
OV
EM
EN
TS
W A la m ed a
St , T uc so n, A
Z
May 12, 2023
ENGINEERING
CONSULTING ELECTRICAL ENGINEERS
INC
1926 East Ft. Lowell Road, Suite 200 Tucson, Arizona 85719-2391
(520) 884-0045
LOCKOUT - TAGOUT - TESTOUT
C-23-005
P22015
E2.2
ELECTRICAL FLOOR PLANS -
PENTHOUSE & MACHINE ROOM LEVEL
SCALE: 1/4''=1'-0'' SCALE: 1/4''=1'-0''
SCALE: 1/4''=1'-0'' SCALE: 1/4''=1'-0''
KEY PLAN | PENTHOUSEKEY PLAN | MACHINE ROOM LEVEL
c a d se rv e r2 C A D D D a ta p ro je c ts
C O T C it y H a ll E le v\ E .2 .d w g
:5 :2
A M
JROSS
7 7
| Sheets |
| CVR - COVER |
| G1.1 - INDEX, ABBREVIATIONS, SYMBOLS & PROJECT DATA |
| A2.1 - FLOOR PLANS - BASEMENT & FIRST FLOOR |
| A2.2 - FLOOR PLANS - PENTHOUSE & MACHINE ROOM LEVEL |
| A5.1 - BUILDING SECTIONS |
| E2.1 - ELECTRICAL FLOOR PLANS - BASEMENT & 1ST FLOOR |
| E2.2 - ELECTRICAL FLOOR PLANS - PENTHOUSE & MACHINE ROOM LEVEL |
File details come from the government source that posted it. Updated .