This is a Scope of Work document for Salt Lake City Corporation's Request for Bid SLCI26088, which solicits bids for the purchase of one Runway Closure Marker. The equipment specifications detail a Hali-Brite RCM-D L-893 (L) LED Lighted X Runway Closure Marker in 2026 model year or city-approved equivalent. The unit must be a current production model with new, unused components and first-class manufacturing workmanship. Key specifications include a 3-cylinder diesel engine that is emissions compliant, a liquid cooling system, a Marathon Electric 6kw 120/240VAC 60Hz generator, and a light assembly featuring 14-foot hinged arms with twenty LED lamps mounted in front and four monitor lamps in the rear. The fuel system must contain at least 50 gallons with a fuel level sensor, and the chassis must be DDOT compliant with standard 2-inch hitch and appropriate lighting. The equipment must be FAA certified, thoroughly tested and tuned prior to delivery, and include freight to Salt Lake City Airport.
The bid must include an all-weather cover and rear tow hitch option as required optional equipment. All replaceable components must be easily accessible for maintenance, with engine oil and coolant drains positioned to drain directly into receptacles. The successful bidder must supply Operation and Maintenance manuals in English, including spare parts documentation. The unit includes a 2-year factory warranty covering all equipment, parts, and components. Bidders must complete a compliance checklist responding with "yes" or "no" to each minimum requirement; any "no" responses require a separate sheet detailing the noncompliance and describing alternatives to be supplied. Willful falsification of compliance responses subjects bidders to suspension and debarment from future bidding.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 6-SLCI26088 RFB.docx | DOCX document | |
| 3-SLCI26088 Attachment 1 City PO terms conditions.pdf | ||
| 1-Confidential+and+Proprietary+Info+Declaration+Form.pdf | ||
| 5-SLCI26088 Attachment 3 Cost Sheet.xlsx | XLSX spreadsheet | |
| 4-SLCI26088 Attachment 4 PO SUPPLEMENTAL TC.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Runway Closure Marker
EXHIBIT “A”
TECHNICAL SPECIFICATIONS
LED Runway Closure X-Marker
Must be filled out completely for bid to be valid.
NOTICE TO BIDDERS: Any bidder who willfully falsifies responses indicating compliance or noncompliance with the minimum requirements listed below will be subject to suspension and/or debarment from bidding.
Each item below must have a yes or no response in the appropriate column. For all “no” responses, attach a separate sheet with full explanation of the “no” response including description of alternative to be supplied.
MINIMUM REQUIREMENT
YES
NO
These technical specifications are intended to provide a minimum acceptable description to purchase of one (1), Hali-Brite RCM-D L-893 (L) LED Lighted X Runway Closure Marker
1. GENERAL
A. The offered unit shall be of the most recent design and current production model design and construction. Successful bidder guarantees all equipment, parts and components offered in its bid to be new and unused.
B. Workmanship shall be consistent with first-class manufacturing processes. Manufacturing shall be performed in a manner that ensures interchangeability of all parts and sub-assemblies.
C. All parts not specifically mentioned which are necessary for the unit to be complete and ready for operation or which are normally furnished as standard equipment shall be supplied by the successful bidder. All parts shall conform in strength, quality and workmanship to the accepted standards of the industry.
D. All systems shall be thoroughly tested and tuned prior to delivery.
E. Unit will be FAA (Federal Aviation Administration) certified.
F. Price must include freight to Salt Lake City Airport.
2. MANUFACTURER
A. Runway Closure Marker shall be a Hali-Brite RCM-D L-893 (L), or city approved equivalent. 2026 model year.
3. ENGINE
A. Engine shall be a 3-cylinder Diesel engine or city approved equivalent. Must be emissions complaint.
B. The engine will be protected from high coolant temperature and low oil pressure.
4. COOLING SYSTEM
A. Unit will have a liquid cooled diesel engine.
5. GENERATOR
A. Generator shall be a Marathon Electric 6kw 120/240VAC 60Hz
6. LIGHT ASSEMBLY
A. The arm length will be 14 feet when operating.
B. The arms will be hinged to the generator housing, swinging upright for use and swinging horizontal to be stowed.
C. Twenty LED lamps will be mounted in front and 4 monitor lamps will be mounted in the rear.
7. FUEL SYSTEM
A. The fuel system will be at least 50 gallons.
B. There will be a sensor to monitor fuel level
8. CHASSIS
A. The trailer will be DDOT compliant with lights and standard 2-inch hitch
9. OPERATION/MAINTENANCE
A. Design shall allow for all replaceable components to be easily removed and replaced. All drains (engine oil and coolant) shall be located such that they can drain directly into a receptacle under the cart. All replaceable filters will be located in such that they are easily accessed during maintenance.
10. REQUIRED OPTIONAL EQUIPMENT
A. RCM All-weather cover B. RCM rear tow hitch option
11. MANUALS
A. The following manuals will be supplied with the unit: Operation, Maintenance (to include spare parts).
B. All will be in English
12. WARRANTY
A. Unit will have a 2-year factory warranty.