USIBWC TCE Parcel 140-01-005_Delta_Final.pdf

PDF 5 MB Posted

Attached to
Trunkline and IOI Rehabilitation Phases 1-3
Solicitation number
191BWC21R0002
Issued by

About this file

This solicitation is seeking proposals for the rehabilitation of approximately 19,730 linear feet of sewer pipeline known as the Trunkline and International Outfall Interceptor in Nogales, Arizona, with an option to rehabilitate an additional 8,634 linear feet. The solicitation is being issued by the United States Section of the International Boundary and Water Commission for the purpose of rehabilitating sections of the existing pipeline through cured-in-place pipe lining and other repairs. Proposals are due by the date specified in the solicitation. The rehabilitation work will be conducted in multiple phases and includes repairs to associated manholes.

View the file

Other files

File Type Posted
191BWC21R0002 Amendment A00012.pdf PDF
191BWC21R0002 Amendment A00011.pdf PDF
191BWC21R0002 TIOI Rehab PH1-3 Specs 20210421.pdf PDF
191BWC21R0002 Revised Per A00011.pdf PDF
191BWC21R0002 TIOI Rehab PH1-3 Specs 20210414.pdf PDF
191BWC21R0002 Amendment A00010.pdf PDF
191BWC21R0002 Revised Per A00010.pdf PDF
191BWC21R0002 Revised Per A00009.pdf PDF
191BWC21R0002 Amendment A00009.pdf PDF
191BWC21R0002 TIOI Rehab PH1-3 Specs 20210412.pdf PDF
191BWC21R0002 Revised Per A00008.pdf PDF
191BWC21R0002 Amendment A00008.pdf PDF
191BWC21R0002 Revised Per A00007.pdf PDF
Last Question and Answer Received Against 191BWC21R0002.pdf PDF
191BWC21R0002 Amendment A00007.pdf PDF
191BWC21R0002 TIOI Rehab PH1-3 Specs 20210406.pdf PDF
USIBWC TCE Parcel 113-38-007A_Delta_Final.pdf PDF
USIBWC TCE Parcel 102-01-076A_Sainz_Final.pdf PDF
191BWC21R0002 Amendment A00006_draft.pdf PDF
191BWC21R0002 TIOI Rehab PH1-3 Specs 20210331.pdf PDF
Additional Questions and Answers Received Against 191BWC21R0002.pdf PDF
USIBWC TCE Parcel 140-01-001A_Harvey_Final.pdf PDF
USIBWC TCE Parcel 102-01-038_Delta_Final.pdf PDF
191BWC21R0002 Amendment A00006.pdf PDF
191BWC21R0002 Revised Per A00006.pdf PDF
Rio Rico Forcemain Drawings and Photos.pdf PDF
UPRR IOI MCL Folder03060-53.pdf PDF
TIOI Pre-Proposal Sign-in.pdf PDF
UPRR Requirements and Guidelines.pdf PDF
191BWC21R0002 Amendment A00005.pdf PDF
191BWC21R0002 Sol Revised Per A00005.pdf PDF
191BWC21R0002 TIOI Rehab PH1-3 Specs 20210317.pdf PDF
Questions and Answers Received Against 191BWC21R0002.pdf PDF
TIOI Revised Drawings_A00005.pdf PDF
TIOI PH1-3 Pre-Proposal Key Points to Contractors.pdf PDF
NIWTP Flow Reports_Jan-Dec2020.pdf PDF
Manhole 89 As-Builts_201710_Rev.pdf PDF
191BWC21R0002 Revised Per A00004.pdf PDF
191BWC21R0002 Revised Per A00004.pdf PDF
191BWC21R0002 Revised Per A00004.pdf PDF
191BWC21R0002 TIOI Rehab PH1-3 Specs 20210205.pdf PDF
191BWC21R0002 IOI MH Repair HS 20210205.pdf PDF
191BWC21R0002 Amendment A00004.pdf PDF
191BWC21R0002 IOI MH Repair FS 20210205.pdf PDF
191BWC21R0002 AMENDMENT A00001.pdf PDF
191BWC21R0002 AMENDMENT A00003.pdf PDF
191BWC21R0002 REVISED.pdf PDF
191BWC21R0002 AMENDMENT A00002.pdf PDF
191BWC21R0002 Client Authorization Letter_Rev.docx DOCX document
AZ20200036 08.21.2020.pdf PDF
Show 40 more

Latest 50 of 71 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

When recorded, return to:

United States International Boundary and Water Commission

ESD

Crystal Cadillo/Ariana Leos 4191 N. Mesa St.

El Paso, TX 79902

Dino Pinouspoulous P.O. Box 1172 Nogales, AZ, 85628

PROPERTY ADDRESS: 9 Ojo Ct., Rio Rico, AZ, 85648

PARCEL NUMBER: 140-01-005

PIPELINE REPAIRS ACCESS AGREEMENT

This Pipeline Repairs Access Agreement ("Agreement") is entered into by and between the United States International Boundary and Water Commission ("USIBWC") and Delta Properties LLP, a(n) Arizona Limited Liability Partnership ("Owner"). USIBWC and Owner are referred to herein as the "Parties."

RECITALS

A. USIBWC operates and jointly owns with the City of Nogales the Nogales

International Wastewater Treatment Plant ("Plant"), located in Rio Rico, Arizona. The Plant is designed to treat to secondary standards wastewater from the cities of Nogales, Arizona, and Nogales, Sonora. Wastewater is conveyed to the Plant through a sewer pipeline ("Pipeline"). The Pipeline is a continuous sewer pipeline located in Nogales, Arizona, that extends roughly nine miles from the United States-Mexico international boundary line to the Plant and carries approximately 15 million gallons of sewage each day to the Plant. The Pipeline requires rehabilitation due to age, lack of maintenance, and increasing demand for wastewater management. USIBWC has developed plans and specifications for the repair and rehabilitation of the Pipeline ("Repairs"), which will be provided to Owner upon request.

Attached hereto as "Exhibit 1" is(are) the applicable plan(s) of work at the property address.

B. In order to make the necessary Repairs, USIBWC requires access to 9 Ojo

Ct., Rio Rico, Arizona, 85648 ("Property"). The Owner’s deed/property information is attached setting forth the legal description of the Property and marked "Exhibit 2." The location of the Property is shown by the Map that is attached and marked "Exhibit 3." The Property’s tax parcel number is 140- 01-005.

C. The Parties desire to state the terms upon which the USIBWC may enter upon the Property and make Repairs. Attached hereto as "Exhibit 4" is the area and location of the temporary construction easement (TCE) requested within the Property.

AGREEMENT

The Parties covenant and agree as follows:

1. Recitals and Warranty of Title. The Recitals and Exhibits are a material part of this Agreement. Owner holds equitable and legal title to and exclusive possession of the Property. Owner has the authority to enter into this Agreement and represents that there is no tenant or other person currently in possession of the Property. The USIBWC has conferred with the Owner and, insofar as a tenant is in possession of the Property, the Owner has informed the USIBWC that the Owner will coordinate and inform the tenant(s) of the access, but no additional agreement is required with the tenant(s). The Owner has provided an affidavit or letter (attached and marked as "Enclosure 1") confirming their responsibility to coordinate/inform their tenants of this agreement, if applicable.

2. Repair Costs. USIBWC shall bear the cost of Repairs.

3. Grant of Right of Access. Owner grants an easement to USIBWC and its representatives, contractors, and any authorized agents to enter on, use, and occupy the Property for the purpose of conducting Repairs. This Agreement is a covenant running with the land, binds Owner and Owner’s heirs, successors, tenants, and assigns, and will terminate only when UISBWC determines that the Repairs are completed or should be discontinued and records a document expressly terminating this Agreement. USIBWC may record this Agreement in the county where the Property is located.

4. Duty of Care. Owner and Owner’s agents, employees, contractors, tenants, invitees, and guests shall not hinder or interfere with the Repairs and shall not damage or tamper with any equipment or other property used in connection with the Repairs. The USIBWC and its contractors shall not obstruct or block the Owner's and Owner's agents', employees', contractors', tenants', invitees', and guests' access to the property.

5. Prior Notice of Activities and Contractor Work. The USIBWC's contractors will use reasonable efforts to give Owner at least thirty (30) calendar days prior notice of entry onto the Property for Repairs on the Pipeline. USIBWC's contractors shall provide a work plan to the Owner at the time of notice including the following information:

a. Contractor's point of contact for the Owner that is available 24 hours/7 days a week;

b. Proposed start date and duration of contractor's work within property;

c. Description of the equipment and/or materials to be temporarily placed/installed temporarily on the Property;

d. Description of the construction work to be performed within the

Property, if applicable; and,

e. Drawing showing the specific limits and size of area within Property to be used and layout of the proposed temporary equipment and/or materials to be used within the area, such as the bypass system.

The Owner shall notify the USIBWC's contractor point of contact within seven (7) calendar days of receiving notice of entry if the Owner identifies that the contractor's proposed layout of temporary equipment and/or materials to be installed within the property will result in obstruction of access to the property by the Owner or Owner's tenant.

6. Notices Required Under This Agreement.

Notices from USIBWC or its contractors to Owner shall be effective when given, if by telephone or email, to:

Dino Pinouspoulous at (520) 281-1988 dinonogales@yahoo.com and, if in writing, to:

Delta Properties LLP Dino Pinouspoulous P.O. Box 1172 Nogales, AZ, 85628

Notices from Owner to USIBWC shall be effective when given, if by telephone or email, to:

Crystal Cadillo

(915) 832-4159 crystal.cadillo@ibwc.gov

OR

Ariana Leos

(915) 832-4168 ariana.leos@ibwc.gov and, if in writing, to:

Attention:

USIBWC-ESD

Crystal Cadillo/Ariana Leos 4191 N. Mesa St.

El Paso, TX 79902

If Owner changes its telephone number or mailing address for purposes of notice under this Agreement, written notice of the change shall be promptly given to USIBWC. If this Agreement requires notices to be provided in writing, telephonic notice will not suffice as notice.

7. Insurance. While this Agreement is in effect, the USIBWC remains self-insured under the Federal Tort Claims Act as an instrumentality of the Federal Government and will require its contractors to comply with the insurance provisions of the construction Contract requiring liability insurance.

8. No Indemnity. Owner and USIBWC or its contractors are responsible for only their own negligence in connection with the Repairs conducted on the Property. Neither Party to this Agreement agrees to indemnify the other Party or hold harmless the other Party from liability hereunder.

9. Damage to Property. USIBWC's contractors will repair any material damage it causes to the Property. All areas utilized and/or disturbed by USIBWC's contractors within the Owner's property shall be restored by the contractor to preconstruction conditions. If Owner or its tenant intentionally or negligently damages the property of the USIBWC or its contractor, then the Owner or its tenants will repair any material damage caused. Existing remedies at law are available to seek compensation or remedy for any damage caused should either party fail to make repairs.

10. Default. Notices of default must be provided in writing. If either Party defaults under this Agreement and the default continues for more than ten (10) days after the effective date of the Party’s written notice stating the specific nature of the default, then the Party may treat the default as a breach of this Agreement.

Notwithstanding the foregoing, in the event Owner notifies USIBWC of a default, if USIBWC determines that the default cannot be cured within the ten-day notice period, then the default shall be deemed cured if USIBWC commences efforts to cure the default within the ten-day notice period. A default is a violation of any term of this agreement. USIBWC’s or its contractor's failure to give notice under Paragraph 5 also constitutes a default under this Agreement. Owner’s failure to provide access under this Agreement is not subject to the ten-day notice period and is an immediate breach of this Agreement.

11. Dispute Resolution. The Parties shall resolve any breach or dispute arising out of this Agreement by arbitration. Proper venue for any civil action, proceeding, or arbitration arising out of this Agreement shall be the United States District Court for Southern Arizona.

12. Exhibits to this Agreement. Exhibits to this Agreement are intended for informational purposes. If there is a conflict between the terms of this Agreement and an Exhibit to this Agreement, the terms of this Agreement shall control.

13. Miscellaneous. (A) This Agreement expresses the entire agreement of the Parties; (B) Owner agrees that Owner is not relying on any promise, agreement, or representation made by USIBWC except as stated in this Agreement;

(C) no modification of this Agreement is valid or enforceable unless the terms of the modification are in writing and signed by the Parties; (D) this Agreement binds and inures to the benefit of the Parties and their agents, heirs, successors, assigns, transferees, executors, and personal representatives; (E) USIBWC shall retain possession of the fully executed original of this Agreement and Owner shall receive exact copies; (F) this Agreement is effective when signed by the Parties; (G) this Agreement is subject to available funding and nothing shall bind USIBWC to expenditures in excess of funds appropriated and allotted for the purposes in this Agreement; (H) this Agreement shall be interpreted and enforced according to Federal law and, when no federal law applies, then the laws of the State of Arizona;

and, (I) this Agreement may be signed in counterparts, each of which shall be treated as an original but which, when taken together, shall constitute one and the same Instrument.

DANIEL AVILA Digitally signed by DANIEL AVILA Date: 2021.03.30 14:51:32 -06'00'

Daniel Avila, Acting Commissioner

3/30/2021

COCHISE

LOCATION OF WORK

PIMA

GRAHAM

PINAL

SANTA

CRUZ

GILA

G R

E E

N L

E E

NAVAJO

APACHE

COCONINO

YAVAPAI

MARICOPA

YUMA

LA PAZ

MOHAVE

A R I Z O N A

UTAH

CALIFORNIA

MEXICO

NEW

MEXICO

NEVADA

UNITED STATES INTERNATIONAL

BOUNDARY AND WATER COMMISSION

REHABILITATION IMPROVEMENTS

TRUNKLINE AND INTERNATIONAL OUTFALL INTERCEPTOR

SANTA CRUZ COUNTY, AZ

PHASE I

333 EAST WETMORE ROAD,

SUITE 400, TUCSON, AZ 85705

(520) 887-1800

PROJECT NET LENGTH : 1.62 MI

U.S. INTERNATIONAL BOUNDARY AND

WATER COMMISSION

NOGALES, AZ

WASTEWATER

TREATMENT

PLANT

C o n t r

N o

I B

M

T

I-GI-0001

PROJECT VICINITY MAP

PROJECT LOCATION MAP

L A

G E

P r o j e c t s I N

F R i b w c I B

W C

E n g i n e e r i n g

S e r v i c e s T a s k

O r d e r

I B

M

T

N o g a l e s

I O

I

D r a w i n g s P h a s e

D s i g n P l a n

S h e e t s

G

I

S

H E

E T

S I B

M

T

I G

I d w g

P l o t t e d

W e d n e s d a y

A p r i l

A

M

ARIZONA

NOGALES

SANTA CRUZ

COUNTY

A

Z

R

U

B

Y

O L D

T U

C S

O N

R

N

M

R

I

P

O

S

G

A

V

E

W

M

A R

I P

O S

A

R

D

C

E

R

R

A

O

N

C

H

E

Z

P

E

N

D

L

E

T

K

IP

P E

R S

T

O

L

T

A

G

O

N

I

H

Y

T

U

C

S

O

N

N

O

G

A

L

E

S

H

W

Y

A

V

P

A

S

E

B

A

B

D

U

S

T

R

I

K

F

A

K

B

L

V

I

D

U

N

I

C

I F

I C

R

R

U N

IO

C

IF

IC

.R

M

E

X

I C

O U

N

I T

T

A

T

E

S

I N

T

E

R

N

A

T

I O

N

U

N

D

A

R

Y

Sheet

Reference

Number:

CONTRACT NO: IBM09D0008

ORDER NO: IBM14T0007

SURVEY CONTROL

HORIZONTAL CONTROL IS BASED ON ARIZONA STATE

PLANE, CENTRAL ZONE, NORTH AMERICAN DATUM OF

1983 (NAD 83). VERTICAL CONTROL IS BASED ON NORTH

AMERICAN VERTICAL DATUM OF 1988 (NAVD 88).

NOT TO SCALE

NOT TO SCALE

NOGALES TOWNSITE

SECTION 17, RANGE 14 EAST,

TOWNSHIP 24 SOUTH GILA AND SALT

RIVER BASE AND MERIDIAN (G& SRB & M)

SANTA CRUZ COUNTY, ARIZONA

LATITUDE: 31° 19' 50.38" N

LONGITUDE: 110° 56' 30.84" W

PHASE I PROJECT

END CIPP PIPING

CL MH #99

STA 464+36.39

N = 162940.08

E = 997040.68

PHASE I PROJECT

BEGIN CIPP PIPING

CL MH #85

STA 378+81.89

N = 154964.51

E = 999076.89

T

R

U

N

K

L

I N

E

I O

I

PHASE 1

STA 81+46

NOGALES

SAN

TA C

R U

Z

C

IT

Y O

F

N O

G

ALES

C O

U N

TY

Solicitation No. 191BWC21R0002

PARCEL 140-01-005 EXHIBIT 1

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text

AutoCAD SHX Text r a b y

D e s i g n e d b y

R e v i e w e d b y

D a t e

S u b m i t t e d b y

D e s c r i p t i o n

D a t e

A c t i o n

S o l i c i t a t i o n

N o

C o n t r a c t

N o

R e v

Sheet

Reference

Number:

F i l e

N a m e

P l o t

D a t e

P l o t

S c a l e

S y m b o l

L A

G E

P r o j e c t s I N

F R i b w c I B g i n e e r i n g

S e r v i c e s T a s k

O r d e r

I B

M

T

N o g a l e s

I O

I

D r a w i n g s P h a s i g n P l a n

S h e e t s

G

I

S

H E

E T

S I B

M

T

I G

I d o t t e d

T u e s d a y

A p r i l

A

M

T r a c k i n g

N o

I B

M T

I G

I d w g

R E

H A

B I L

I T

A T

I O

N

I M

P R

O V

E M

E N

T S

T R

U N

K L

I N

E

A

T E

R N

A T

I O

N A

L

O

U T

F A

L L

I N

T E

R C

E P

T O

R

S

A N

U

Z

C

O U

N T

Y

A

Z

P H

A S

E

I

P R

O J E

U R

S

C

O R

P O

R A

T I O

N

E

A S

T

W

E T

M O

A

D

S U

I T

E

C

S O

N

A

Z

U S

I N

T E

R N

A T

I O

N A

L

B

O U

N D

A R

Y

W A

T E

R

C

O M

M I S

S I O

N

N O

G A

L E

S

A

Z

S L

S

S L

S

T S

S

C H

A R

L E

S

P

E D

R I

P

E

N O

T

T

O

S

C A

L E

I-GI-0004

R E

Q U

I R

N

H O

H

A B

I L

I T

A T

I O

N

NOTES:

1. SEE DRAWINGS I-CU-2035 THRU I-CU-2044 FOR PLAN AND PROFILES.

2. SEE DRAWINGS I-CU-3001 AND I-CU-3002 FOR MANHOLE REHABILITATION

DETAILS (PROTECTIVE LINER SYSTEM AND CARBON FIBER COMPOSITE).

3. REHABILITATION WITH PROTECTIVE LINER SYSTEM REQUIRED FOR CONCRETE

MANHOLES IN EITHER GOOD OR FAIR CONDITIONS.

4. REHABILITATION WITH CARBON FIBER COMPOSITE REQUIRED FOR BRICK

MANHOLES AND CONCRETE MANHOLES IN POOR CONDITION.

5. ALL MANHOLES SHOWN IN TABLE ABOVE SHALL BE INCLUDED IN THIS PHASE OF

WORK.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR BYPASSING OF FLOW FROM THE

LATERALS LISTED IN THE LATERAL INFORMATION TABLE ON THIS DRAWING.

REQUIRED MANHOLE REHABILITATION TABLE

MH NUMBER STATION RIM ELEVATION INVERT ELEVATION

PIPE DIAMETER

(INCHES)

MANHOLE

DEPTH (FEET)

PROTECTIVE

LINER

SYSTEM

HYDRAULIC

WATER PLUG

(EST. CF)

CARBON

FIBER

COMPOSITE

RAISE

MANHOLE

TO GRADE

APPLICABLE

DETAILS

(SHEET I-CU-3001/I-CU-3002)

REQUIRED MANHOLE REHABILITATION

97A

97B

378+81.89

389+54.26

390+61.25

393+41.07

394+96.93

407+62.82

409+94.63

414+96.11

417+27.55

429+05.16

440+68.08

450+73.53

452+90.39

453+60.01

453+71.84

461+30.18

464+36.39

3540.36

3529.33

3521.56

3523.04

3513.16

3517.54

3516.93

3514.01

3516.28

3496.79

3505.44

3488.95

3483.47

3482.70

3482.96

3485.72

3481.52

3523.19

3512.20

3511.14

3509.51

3507.63

3499.08

3497.35

3494.43

3492.56

3483.50

3478.94

3474.74

3473.72

3473.77

3473.75

3472.45

3472.82

17.17

17.13

10.42

13.53

5.53

18.46

19.58

19.58

23.72

13.29

26.50

14.21

9.75

8.93

9.21

13.27

8.70

X

X

NO REHABILITATION REQUIRED

X

X

X

X

X

X

X

X

X (10.8)

X (6.6)

X

X

X

X

X

X

X

X

1,2,3

1,2,3

5'L X 5'W X 5'H

MANHOLE

DIAMETER

(FEET)

U.N.O.

IOI MANHOLE

CONNECTING LATERAL

N. PENA BLANCA

US FOREST SERVICE

RIO RICO FORCEMAIN

LATERAL DIAMETER

(INCHES)

ESTIMATED LENGTH ALONG LATERAL TO NEXT

UPSTREAM MANHOLE

(FEET)

ESTIMATED AVERAGE FLOW

(GPM)

UNKNOWN

UNKNOWN

UNKNOWN

LATERAL INFORMATION TABLE

X

PARCEL 140-01-005 EXHIBIT 1

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

C

I

P

C

I

P

C

427+00 428+00 429+00 430+00 431+00 432+00 433+00 434+00 435+00 436+00 437+00 438+00

S

CL MH 94

STA = 429+05.16

N=159698.75

E=997635.32

RIM: 3496.79

30"DIA. RCP PIPE

INV. EL.3484.00

36" DIA. RCP PIPE

INV. EL.3483.50

(SEE NOTE 4)

X

X

X

X

X

X

X

35003500

P O

T R

E R

O

C R

E E

K

G R

A V

E L

R

O A

D

G R

A V

E L R

O A

D

EXISTING 1177.6 LF OF 30" RCP

TO BE REHABILITATED WIITH

CURED IN PLACE PIPE LINER

EXISTING 1162.9 LF OF 36" RCP

TO BE REHABILITATED WIITH

CURED IN PLACE PIPE LINER

RAISE TOP OF MH 94 TO GRADE

40' PIPELINE EASEMENT

PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE

PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE PLE

SS

x

SS

x

SS

x

SS

x

SS

x

SS

x

SS

x

SS

x

SS

x

SS

x

SS

x

SS

x

SS

x

SS

x

SS

x

SS

X

X

X

X

X X X X

UPRR FENCE

POTENTIAL BYPASS

PIPELINE ALIGNMENNT

427+00

428+00

429+00

430+00

431+00

432+00

433+00

434+00

435+00

436+00

437+00

438+00

M H

N

O

S T

A

R

30" R C

P P

IP

E

S = 0.0073

36" RCP PIPE S = 0.0044

30" INV. EL.3484.00

36" INV. EL.3483.50

EXISTING GROUND

EXISTING GROUND ELEVATION

AT PIPE CENTERLINE

P O

T R

E R

O

C

R E

E K

RAISE TOP OF MANHOLE TO GRADE

WITH NEW BARREL SECTION

(SEE NOTE 2)

PLAN

STA. 427+00.00 TO STA. 438+00.00

PROFILE

STA. 427+00.00 TO STA. 438+00.00

P L

O

F I L

E S

S T

A

T

O

S

T A

I-CU-2041

0 40' 80'

SCALE: 1" = 40'

20'

0 5' 10'

SCALE: 1" = 5'

VERTICAL

HORIZONTAL

M A

T C

H

L

I N

E

A

T

S

T A

T I O

N

M A

T C

H

L

I N

E

A

T

S

T A

T I O

N

D r a

D e s i g n e d b y

R e v i e w e d b y

D a t e

S u b m i t t e d b y

D e s c r i p t i o n

D a t e

A c t i o n

S o l i c i t a t i o n

N o

C o n t r a c t

N o

R e v

Sheet

Reference

Number:

F i l e

N a m e

P l o t

D a t e

P l o t

S c a l e

S y m b o l

L A

G E

P r o j e c t s I N

F R i b w c I B g i n e e r i n g

S e r v i c e s T a s k

O r d e r

I B

M

T

N o g a l e s

I O

I

D r a w i n g s P h a s i g n P l a n

S h e e t s

C

F S

H E

E T

S I B

M

T

I C

U d o t t e d

W e d n e s d a y

A p r i l

A

M

T r a c k i n g

N o

I B

M T

I C

U d w g

R E

H A

B I L

I T

A T

I O

N

I M

P R

O V

E M

E N

T S

T R

U N

K L

I N

E

A

T E

R N

A T

I O

N A

L

O

U T

F A

L L

I N

T E

R C

E P

T O

R

S

A N

U

Z

C

O U

N T

Y

A

Z

P H

A S

E

I

P R

O J E

U R

S

C

O R

P O

R A

T I O

N

E

A S

T

W

E T

M O

A

D

S U

I T

E

C

S O

N

A

Z

U S

I N

T E

R N

A T

I O

N A

L

B

O U

N D

A R

Y

W A

T E

R

C

O M

M I S

S I O

N

N O

G A

L E

S

A

Z

S L

S

S L

S

T S

S

C H

A R

L E

S

P

E D

R I

P

E

N O

T

T

O

S

C A

L E

CL UNION PACIFIC NOGALES BRANCH (200' R.O.W.)

R.R. R.O.W.

R.R. R.O.W.

R.R. R.O.W.

R.R. R.O.W.

PHASE I (CONT.)

PHASE I (CONT.)

NOTES:

1. SEE SPECIFICATION SECTION 46.04.00 FOR CURED-IN-PLACE PIPE (CIPP) REQUIREMENTS.

2. SEE DETAIL 1, SHEET I-CU-3001 FOR MANHOLE FRAME AND COVER ADJUSTMENT.

3. THE CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH USACE NATION WIDE PERMIT

#12 AND ADEQ 401 WATER QUALITY CERTIFICATION PROVISIONS WHEN CONDUCTING ANY

WORK WITHIN POTRERO CREEK.

4. SEE DETAIL 2, SHEET I-CU-3001 FOR MANHOLE REHABILITATION.

5. FOR TCE, SEE SHEET I-GC-1005.

6. SEE SHEET I-GI-0002 FOR LEGEND AND ABBREVIATIONS.

7. SEE SHEET I-GI-0003 FOR GENERAL NOTES.

PARCEL 140-01-005 EXHIBIT 1

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DETAIL NO.

STANDARD DETAIL

ENGLISH

REVISED

DETAIL NO.

01-01-2015

MANHOLE FRAME

AND COVER ADJUSTMENT

ADJUSTING RING DETAIL

SPACER TYPE

BRICK

4"X2" STEEL SPACER

GROUT

REQUIRED THICKNESS

GREATER THAN 2"

" TO 2"

LESS THAN

NOTES:

1. CONTRACTORS SHALL ADJUST ALL MANHOLE RINGS AND

COVERS, INCLUDING MANHOLES OUTSIDE OF THE

PAVEMENT.

2. COAT INTERIOR SURFACES OF GRADE RINGS WITH

REHABILITATION COATING SPECIFIED FOR THAT MANHOLE.

3. GROUT SHALL BE USED BETWEEN FRAME AND ADJUSTING

RING TO ACHIEVE WATER TIGHTNESS.

4. MAXIMUM HEIGHT OF OPENING BETWEEN THE BOTTOM OF

THE MANHOLE CONCRETE TOP AND TOP GRADE RING SHALL

BE 24". FOR MANHOLES REQUIRING ADJUSTMENTS GREATER

THAN 24" THE ADJUSTMENT SHALL INCLUDE NEW BARREL

SECTIONS, PER DETAIL ON SHEET I-CU-3003.

2-1/8"

1/4"

1-5/8"

1/4"

1-3/4"

2-1/4"

1/4"

1/4"

2-1/4"

1"

6"

12" MIN.

BOTH SIDES

OUT OF

PAVEMENT-FINISH

GRADE

(2) NO.2 HOOPS FOR 4"

RING TIED WITH NO.4

A.S. & W. GAUGE WIRE.

6" & 8" RING REQUIRE

(4) NO.2 HOOPS.

MEDIUM BROOM

FINISH WITH

RADIALLY SCORED

MARKS (4 MIN.)

NEW MANHOLE

LID AND FRAME

EXISTING OR RECENTLY

INSTALLED PAVEMENT

#4 REINFORCING STEEL HOOP EQUALLY

CENTERED HORIZONTALLY AND VERTICALLY

(IF REQUIRED BY AGENCY)

4000 PSI CONCRETE

COMPACTED SUBGRADE TO 95%

MAXIMUM DRY DENSITY

(BENEATH ROADWAY) OR

85% MAXIMUM DRY DENSITY

(OPEN GRASS SURFACES)

FLAT REINFORCED CONCRETE TOP

M

A X

S

T

E S

M

I N

M

I N

GROUT INTERIOR

SURFACE OF

ADJUSTMENT

RINGS

CONTINUOUS

V A

R I E

S

REHABILITATE ALL INTERIOR CONCRETE SURFACES

(INCLUDING INTERIOR OF CONCRETE MANHOLE TOP)

WITH EITHER PROTECTIVE LINING SYSTEM OR

CARBON FIBER COMPOSITE SYSTEM

PROTECT STEPS IN-PLACE

NOTES:

1. SEE SHEET I-GI-0004 FOR TABLE IDENTIFYING REQUIRED MANHOLE REHABILITATION SYSTEM

(CARBON PROTECTIVE LINER SYSTEM OR CARBON FIBER COMPOSITE SYSTEM).

2. MANHOLE FRAME AND ADJUSTMENT TO GRADE SHALL BE COMPLETED PRIOR TO ANY

MANHOLE REHABILITATION.

3. PRIOR TO PLACEMENT OF THE CIPP, HYDROPHILIC END SEALS SHALL BE PLACED AT THE

DOWNSTREAM AND UPSTREAM ENDS OF THE EXISTING PIPE TO MAKE A TIGHT FITTING SEAL

WITH THE CIPP AT EACH MANHOLE. SEE DETAILS ON SHEET I-CU-3002.

4. CURED-IN-PLACE PIPE SHALL BE THEN INSTALLED INTO EACH SEWER REACH.

5. TO PROVIDE ACCESS TO THE MANHOLE, TOP HALF OF THE LINER SHALL BE NEATLY CUT

OFF A MAXIMUM OF 4 INCHES AND A MINIMUM OF 2 INCHES FROM THE MANHOLE WALLS TO

ALLOW THE LINER TO LOCK IN AT THE MANHOLE OPENING.

6. SEE SPECIFICATION 46.04.00 CURED-IN-PLACE PIPE (CIPP) FOR FOR OTHER CIPP

INSTALLATION REQUIREMENTS.

7. FOR MANHOLES, SEE EITHER SPECIFICATION 46.05.00 PROTECTIVE LINER SYSTEM OR

SPECIFICATION 46.06.00 CARBON FIBER COMPOSITE SYSTEM, AS IDENTIFIED ON THE

REQUIRED MANHOLE REHABILITATION TABLE SHOWN ON SHEET I-GI-0004.

8. SEE DETAIL 5, SHEET I-CU-3002 FOR CIPP LINER/MANHOLE REHABILITATION INTERFACE.

9. MANHOLE REHABILITATION USING EITHER A PROTECTIVE LINER SYSTEM

(SPECIFICATION 46.05.00) OR A CARBON FIBER COMPOSITE (SPECIFICATION 46.06.00)

SHALL BE COMPLETED AFTER THE INSTALLATION OF THE CIPP.

10. SEE SHEET I-GI-0002 FOR LEGEND AND ABBREVIATIONS.

11. SEE SHEET I-GI-0003 FOR GENERAL NOTES.

WHEN INSTALLING CIPP LINER THROUGH

MANHOLE REMOVE TOP PORTION OF LINER

WITHIN THE MANHOLE TO RE-ESTABLISH

ACCESS. WHEN TERMINATING CIPP LINER AT

MANHOLE, INSTALL AND SEAL IN ACCORDANCE

WITH DETAIL 5, ON SHEET I-CU-3002.

D r a

D e s i g n e d b y

R e v i e w e d b y

D a t e

S u b m i t t e d b y

D e s c r i p t i o n

D a t e

A c t i o n

S o l i c i t a t i o n

N o

C o n t r a c t

N o

R e v

Sheet

Reference

Number:

F i l e

N a m e

P l o t

D a t e

P l o t

S c a l e

S y m b o l

L A

G E

P r o j e c t s I N

F R i b w c I B g i n e e r i n g

S e r v i c e s T a s k

O r d e r

I B

M

T

N o g a l e s

I O

I

D r a w i n g s P h a s i g n P l a n

S h e e t s

C

F S

H E

E T

S I B

M

T

I C

U d o t t e d

W e d n e s d a y

A p r i l

A

M

T r a c k i n g

N o

I B

M T

I C

U d w g

R E

H A

B I L

I T

A T

I O

N

I M

P R

O V

E M

E N

T S

T R

U N

K L

I N

E

A

T E

R N

A T

I O

N A

L

O

U T

F A

L L

I N

T E

R C

E P

T O

R

S

A N

U

Z

C

O U

N T

Y

A

Z

P H

A S

E

I

P R

O J E

U R

S

C

O R

P O

R A

T I O

N

E

A S

T

W

E T

M O

A

D

S U

I T

E

C

S O

N

A

Z

U S

I N

T E

R N

A T

I O

N A

L

B

O U

N D

A R

Y

W A

T E

R

C

O M

M I S

S I O

N

N O

G A

L E

S

A

Z

S L

S

S L

S

T S

S

C H

A R

L E

S

P

E D

R I

P

E

N O

T

T

O

S

C A

L E

I B

M T

I-CU-3001

M A

N H

O L

E

R

E H

A B

I L

I T

A T

I O

N

D

E T

A I L

S

S H

E E

MANHOLE SURFACES TO RECEIVE REHABILITATION

DETAIL

NOT TO SCALE

DETAIL

NOT TO SCALE

PARCEL 140-01-005 EXHIBIT 1

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text a

D e s i g n e d b y

R e v i e w e d b y

D a t e

S u b m i t t e d b y

D e s c r i p t i o n

D a t e

A c t i o n

S o l i c i t a t i o n

N o

C o n t r a c t

N o

R e v

Sheet

Reference

Number:

F i l e

N a m e

P l o t

D a t e

P l o t

S c a l e

S y m b o l

L A

G E

P r o j e c t s I N

F R i b w c I B g i n e e r i n g

S e r v i c e s T a s k

O r d e r

I B

M

T

N o g a l e s

I O

I

D r a w i n g s P h a s i g n P l a n

S h e e t s

C

F S

H E

E T

S I B

M

T

I C

U d o t t e d

W e d n e s d a y

A p r i l

A

M

T r a c k i n g

N o

I B

M T

I C

U d w g

R E

H A

B I L

I T

A T

I O

N

I M

P R

O V

E M

E N

T S

T R

U N

K L

I N

E

A

T E

R N

A T

I O

N A

L

O

U T

F A

L L

I N

T E

R C

E P

T O

R

S

A N

U

Z

C

O U

N T

Y

A

Z

P H

A S

E

I

P R

O J E

U R

S

C

O R

P O

R A

T I O

N

E

A S

T

W

E T

M O

A

D

S U

I T

E

C

S O

N

A

Z

U S

I N

T E

R N

A T

I O

N A

L

B

O U

N D

A R

Y

W A

T E

R

C

O M

M I S

S I O

N

N O

G A

L E

S

A

Z

S L

S

S L

S

T S

S

C H

A R

L E

S

P

E D

R I

P

E

N O

T

T

O

S

C A

L E

I B

M T

I-CU-3002

M A

N H

O L

E

R

E H

A B

I L

I T

A T

I O

N

D

E T

A I L

S

S H

E E

24" CAST IRON WATERTIGHT

MANHOLE FRAME AND COVER

424-1 ENGLISH

STANDARD DETAIL

424-1

XX

XX

M

AD

E

IN

U

SA

XXX

CLASS 35B

XX

X

AASHTO M

XX

XX

USA

CLASS 35B

AASHTO M306

XXX

XXX

NC

AG

E

IY DENTIF ICATION

U T I L I T Y T Y PE

33 3/4"

INITIAL BACKFILL

FOUNDATION

SAWCUT

SEE NOTE 2.

SPRINGLINE

BEDDING

HAUNCHING

4" TOPSOIL

F I N

A L

B

A C

K F

I L L

F I N

A L

B

A C

K F

I L L

E M

B A

N K

M E

N T

P I P

E

Z

O N

E

O.D. CLEARANCE

PIPE O.D. +24"

PAVED AREAS UNPAVED AREAS

TYPICAL TRENCH SECTION

NOTE:

1. SEE SPECIFICATION SECTION 31.23.20 FOR PIPE, BEDDING,

BACKFILL, AND SURFACE RESTORATION REQUIREMENTS.

NATIVE BACKFILL

DETAIL

NOT TO SCALE

DETAIL 4

NOT TO SCALE

DETAIL

NOT TO SCALE

2. JOINT LOCATION OR JOINT CONFIGURATION SHALL BE TO

ELIMINATE FULL DEPTH SAW CUT JOINTS FROM BEING

LOCATED WITHIN A WHEEL PATH.

12"

ASPHALT CONCRETE

(MATCH THICKNESS

OF EXISTING PAVEMENT)

NOTES:

1. SEE SHEET I-GI-0002 FOR LEGEND AND ABBREVIATIONS.

2. SEE SHEET I-GI-0003 FOR GENERAL NOTES.

EXISTING

RCP PIPE

MANHOLE REHABILITATION

EITHER PROTECTIVE LINER SYSTEM

OR CARBON FIBER COMPOSITE

NEW END SEAL

SLEEVE (TYP)

MANHOLE REHABILITATION

EITHER PROTECTIVE LINER SYSTEM

OR CARBON FIBER COMPOSITE

LINER/MANHOLE REHABILITATION INTERFACE

WHEN TERMINATING CIPP LINER AT MANHOLE

EXISTING

RCP PIPE

CIPP LINER (TYP)

NOTE 1

EXISTING

MANHOLE

NOTE:

1. CONTRACTOR SHALL LEAVE APPROXIMATELY

2 INCHES OF CIPP FROM THE EDGE OF THE

CHANNEL ON BOTH SIDES TO ALLOW FOR

POSSIBLE SHRINKAGE OF LINER.

2. DO NOT APPLY MANHOLE REHABILITATION SYSTEM

TO LATERAL. THOROUGHLY CLEAN INTERIOR AND

EXTERIOR SURFACES OF ALL LATERALS OF ANY

SYSTEM COMPONENT.

SELECT

BACKFILL

MATERIAL

AGGREGATE

BASE COURSE

EXISTING LATERAL

(SEE NOTE 2)

PARCEL 140-01-005 EXHIBIT 1

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DETAIL NO.

AutoCAD SHX Text

REVISED

AutoCAD SHX Text

DETAIL NO.

AutoCAD SHX Text 01-01-2012

AutoCAD SHX Text

%%UFRAME TOP VIEW

AutoCAD SHX Text

%%UCOVER TOP VIEW

AutoCAD SHX Text

FRAME WT. (CL. 35) - 180 LBS

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text

%%UCOVER BOTTOM VIEW

AutoCAD SHX Text

HEAT DATE

AutoCAD SHX Text

MANUFACTURES NAME

AutoCAD SHX Text 1 1/16"

AutoCAD SHX Text 26 1/8"

AutoCAD SHX Text 1 3/16"

AutoCAD SHX Text 22 3/4"

AutoCAD SHX Text 2 1/2"

AutoCAD SHX Text

COVER WT. (CL. 35) - 188 LBS

AutoCAD SHX Text

MANUFACTURES NAME

AutoCAD SHX Text

ORIGIN

AutoCAD SHX Text

AASHTO M306 CLASS 35B

AutoCAD SHX Text

MODEL NUMBER

AutoCAD SHX Text

HEAT DATE

AutoCAD SHX Text

MODEL NUMBER MANUFACTURES NAME

AutoCAD SHX Text

RECYCLE SIGN

AutoCAD SHX Text

OPTIONAL LOGO OR AREA WITH RAISED CIRCLE FLUSH 1/8'

AutoCAD SHX Text

RAISED RINGS 1/8"

AutoCAD SHX Text 6"

AutoCAD SHX Text 26 3/8"

AutoCAD SHX Text 27 13/16"

AutoCAD SHX Text 1 3/16"

AutoCAD SHX Text 4 1/16"

AutoCAD SHX Text 24"

AutoCAD SHX Text R3/4"

AutoCAD SHX Text

BATTER 3/16"

AutoCAD SHX Text NOTE: : LETTERING ON MANHOLE COVER TO CONTAIN NAME OF AGENCY AND UTILITY FOR WHICH MANHOLE IS NEEDED, (I.E. "PHOENIX SANITARY SEWER"), OR AS DIRECTED. THE TOTAL WIDTH OF INDIVIDUAL LETTERS TO BE SUCH THAT LETTERS AND WORDS ARE EQUALLY SPACED AND BALANCED TO FORM A COMPLETE CIRCLE WITH SPACERS BEFORE AND AFTER THE WORD IDENTIFYING THE AGENCY INVOLVED. LETTERS TO BE 2" IN HEIGHT AND RAISED FLUSH W/ TOP OF COVER. TYPE OF LETTERS TO BE SUBMITTED FOR APPROVAL. WEIGHT OF CASTINGS SHALL BE NO MORE THAN 2% MORE OR LESS THAN THE APPROXIMATE WEIGHT SPECIFIED. CASTINGS SHALL CONFORM TO ASTM A-48, CLASS 35 AND AASHTO M306. THE BEARING SURFACES OF THE FRAMES AND COVERS SHALL BE MACHINED AND THE COVERS SHALL SEAT FIRMLY WITHOUT ROCKING. ALL DIMENSIONS SHALL HAVE A 1/16" TOLERANCE.

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text

SECTION B

AutoCAD SHX Text

SECTION C

AutoCAD SHX Text

SECTION A

AutoCAD SHX Text

SECTION D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text 3/16"

AutoCAD SHX Text

BATTER

AutoCAD SHX Text R1/4"

AutoCAD SHX Text R3/8"

AutoCAD SHX Text 7"

AutoCAD SHX Text

CONCEALED PICK DETAIL

AutoCAD SHX Text 1 3/8"

AutoCAD SHX Text 5/8"

AutoCAD SHX Text

WITH GASKET

AutoCAD SHX Text 1/8"

AutoCAD SHX Text 3/16"

AutoCAD SHX Text

BATTER

AutoCAD SHX Text 3/4"

AutoCAD SHX Text

TAPER 1/2" TO 3/4"

AutoCAD SHX Text

MACHINED

AutoCAD SHX Text

MACHINED

AutoCAD SHX Text 2"

AutoCAD SHX Text 1/4"

AutoCAD SHX Text 9/16"

AutoCAD SHX Text

MIN. 8 GUSSETS W/ MIN. TAPER 5/8" TO 3/4"

AutoCAD SHX Text

NAME OF AGENCY OR UTILITY REQUIRED 1/8" RAISED

7/8" DIA DRILL AS NECESSARY FOR MACHINING

a

D e s i g n e d b y

R e v i e w e d b y

D a t e

S u b m i t t e d b y

D e s c r i p t i o n

D a t e

A c t i o n

S o l i c i t a t i o n

N o

C o n t r a c t

N o

R e v

Sheet

Reference

Number:

F i l e

N a m e

P l o t

D a t e

P l o t

S c a l e

S y m b o l

L A

G E

P r o j e c t s I N

F R i b w c I B g i n e e r i n g

S e r v i c e s T a s k

O r d e r

I B

M

T

N o g a l e s

I O

I

D r a w i n g s P h a s i g n P l a n

S h e e t s

C

F S

H E

E T

S I B

M

T

I C

U d o t t e d

W e d n e s d a y

A p r i l

A

M

T r a c k i n g

N o

I B

M T

I C

U d w g

R E

H A

B I L

I T

A T

I O

N

I M

P R

O V

E M

E N

T S

T R

U N

K L

I N

E

A

T E

R N

A T

I O

N A

L

O

U T

F A

L L

I N

T E

R C

E P

T O

R

S

A N

U

Z

C

O U

N T

Y

A

Z

P H

A S

E

I

P R

O J E

U R

S

C

O R

P O

R A

T I O

N

E

A S

T

W

E T

M O

A

D

S U

I T

E

C

S O

N

A

Z

U S

I N

T E

R N

A T

I O

N A

L

B

O U

N D

A R

Y

W A

T E

R

C

O M

M I S

S I O

N

N O

G A

L E

S

A

Z

S L

S

S L

S

T S

S

C H

A R

L E

S

P

E D

R I

P

E

N O

T

T

O

S

C A

L E

I B

M T

I-CU-3003

N E

W

C

O N

C R

E T

E

S

A N

I T

A R

Y

S

E W

N

H O

L E

420-1

CONCRETE SANITARY SEWER MANHOLE

DETAIL NO.

STANDARD DETAIL

ENGLISH

01-01-2015

REVISED

420-1

DETAIL NO.

420-2

DETAIL NO.

STANDARD DETAIL

ENGLISH

REVISED

420-2

DETAIL NO.

PRECAST CONCRETE MANHOLE BASE

01-01-2015

420-3

DETAIL NO.

STANDARD DETAIL

ENGLISH

01-01-2015

REVISED

420-3

DETAIL NO.

CONCRETE MANHOLE BASE

DETAIL

NOT TO SCALE

DETAIL 7

NOT TO SCALE

DETAIL

NOT TO SCALE

NOTES:

1. SEE SHEET I-GI-0002 FOR LEGEND AND ABBREVIATIONS.

2. SEE SHEET I-GI-0003 FOR GENERAL NOTES.

PARCEL 140-01-005 EXHIBIT 1

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

%%UTYPE 'A' TOP

AutoCAD SHX Text

4" TYP.

AutoCAD SHX Text

(PRECAST ECCENTRIC CONICAL TOP MANHOLE)

AutoCAD SHX Text

USE BUTYL RUBBER MASTIC JOINT SEALANT ON ALL JOINTS; EXCEPT TOP ADJUSTMENT RINGS

AutoCAD SHX Text

8" IF MANHOLE IS 13' OR LESS 12" IF MANHOLE IS OVER 13'

AutoCAD SHX Text

OVERALL ADJUSTMENT RING HEIGHT SHALL BE 12" MIN TO 18" MAX (TYP)

AutoCAD SHX Text NOTES: 1. PRECAST STEEL REINFORCED MANHOLE SECTIONS PRECAST STEEL REINFORCED MANHOLE SECTIONS SHALL BE MANUFACTURED IN ACCORDANCE WITH ASTM C 478 EXCEPT AS MODIFIED HEREIN. 2. CAST-IN-PLACE MANHOLE BASE TO BE CAST-IN-PLACE MANHOLE BASE TO BE CONSTRUCTED IN ONE PLACEMENT. 3. CAST-IN-PLACE MANHOLE BASE SHELF AND CAST-IN-PLACE MANHOLE BASE SHELF AND CHANNEL TO RECEIVE SMOOTH TROWEL FINISH. 4. MANHOLE COATINGS PER AGENCY. MANHOLE COATINGS PER AGENCY. 5. SEE DETAIL 1 ON SHEET I-CU-3001 FOR FINAL SEE DETAIL 1 ON SHEET I-CU-3001 FOR FINAL ADJUSTMENT TO GRADE. 6. ANY MANHOLE OVER 20' SHALL REQUIRE ENGINEER ANY MANHOLE OVER 20' SHALL REQUIRE ENGINEER (STRUCTURAL) CALCS. 7. THE MANHOLE ACCESS POINT SHALL BE ORIENTED THE MANHOLE ACCESS POINT SHALL BE ORIENTED IN SUCH A WAY THAT THE OPENING IS DIRECTLY ABOVE THE LOWEST INVERT, OR AS OTHERWISE DIRECTED BY THE PLANS OR ENG. 8. FOR PRECAST BASE SEE DETAIL 7 ON THIS SHEET. FOR PRECAST BASE SEE DETAIL 7 ON THIS SHEET. 9. FLAT TOPS SHALL ONLY BE USED WITH APPROVAL FLAT TOPS SHALL ONLY BE USED WITH APPROVAL FROM THE ENGINEER.

AutoCAD SHX Text

PRECAST RISER SECTIONS AS REQUIRED

AutoCAD SHX Text

24" FRAME & COVER PER STD DETAIL 3 ON SHEET I-CU-3002

AutoCAD SHX Text

%%U(PRECAST FLAT TOP M.H.)

AutoCAD SHX Text

8"MIN.

AutoCAD SHX Text

8" TYP.

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

3" MIN. 5" MAX.

AutoCAD SHX Text

KEYWAY PRESSED INTO BASE TO MATCH PRECAST RISER

AutoCAD SHX Text

DIAMETER PER PLAN

AutoCAD SHX Text

FLAT REINFORCED CONC. TOP

AutoCAD SHX Text

FINISH GRADE (TYP)

AutoCAD SHX Text

24" TO 26-3/4" ON 48" MANHOLE 30" ON 60" MANHOLE (TYP)

AutoCAD SHX Text

CEMENT MORTAR

AutoCAD SHX Text

3000 PSI CONCRETE BASE

AutoCAD SHX Text

30" MIN. 36" MAX.

AutoCAD SHX Text

24" MAX ADJUSTING RINGS PER DETAIL 1, ON SHEET I-CU-3001 (TYP)

AutoCAD SHX Text

CONCRETE SHELF SHALL BE PER SECTION A-A DETAIL 8, ON THIS SHEET

AutoCAD SHX Text

24" MAX.

AutoCAD SHX Text

30"DIA MIN.

AutoCAD SHX Text NOTES: PRECAST, MANUFACTURER SHALL BE AN NATIONAL PRECAST CONCRETE ASSOCIATION (NPCA) CERTIFIED PLANT. ENTIRE ENTIRE PRECAST BASE SHALL BE MANUFACTURED AT THE PLANT PER ASTM C478. 4000 PSI CONCRETE SHALL BE USED FOR PRECAST MANHOLE BASES. SPRING LINE OF CAST-IN-PLACE BELL SHALL STOP AT INSIDE FACE OF MANHOLE. JOINTS FOR BARREL SECTION SHALL BE TONGUE AND GROOVE TYPE. ALL LIFTING HOLES SHALL BE SEALED WITH GROUT. ALL PRECAST MANHOLE BASES SHALL BE PLACED ON 8" MINIMUM OF ABC COMPACTED TO 100% MAXIMUM DENSITY. ALL MODIFICATIONS SHALL BE APPROVED BY THE ENGINEER. MINIMUM WALL THICKNESS SHALL BE PER ASTM C478 (MIN 5"). REINFORCEMENT SHALL BE DESIGNED BY AN ARIZONA REGISTERED PROFESSIONAL ENGINEER.

AutoCAD SHX Text CHANNEL TRANSITION SHALL BE CONSTANT FROM INLET TO OUTLET OF MANHOLE TO FACILITATE SMOOTH TRANSITIONS AND ACCOMMODATE CORRESPONDING MANDREL. THERE SHALL BE NO HARD CONNECTIONS (GROUTED) INTO THE MANHOLE BASE UNLESS APPROVED BY THE ENGINEER. ALL SEWER SERVICE CONNECTIONS SHALL HAVE THE SAME CONNECTION TYPES IN THE PRECAST MANHOLE BASE. ALL CORE HOLES INTO THIS STRUCTURAL PRECAST BASE SHALL BE COATED WITH AN APPROVED COATING MATERIAL. THE MANHOLE BOTTOM SHALL EXTEND OUTSIDE THE MANHOLE WALL A MINIMUM 6" WIDE ON 48" BASES, 7" WIDE ON 60" BASES, AND 8" WIDE ON 72" BASES. EXTENDED BOTTOM SHALL BE A MINIMUM OF 5" THICK. ALL PIPE CONNECTIONS SHALL BE IN COMPLIANCE WITH ASTM C923.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PROVIDE 1' LENGTH OF FACTORY PRODUCED CLAY PIPE

AutoCAD SHX Text

STANDARD LENGTH PIPE

AutoCAD SHX Text

PROVIDE 2' LENGTH OF FACTORY PRODUCED EXTRA STRENGTH VITRIFIED CLAY PIPE

AutoCAD SHX Text

DIAMETER PER PLAN

AutoCAD SHX Text

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

AutoCAD SHX Text

OUTLET PIPE PER APPROVED PLANS

AutoCAD SHX Text

UNDISTURBED NATIVE SOIL

AutoCAD SHX Text

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

CLAY PIPE

AutoCAD SHX Text

OTHER PIPE TYPES

AutoCAD SHX Text

8" MIN.

AutoCAD SHX Text

TRENCH FACE (TYP)

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

AutoCAD SHX Text

IF NO SIDE SEWERS, FORM ONE CONTINUOUS CHANNEL

AutoCAD SHX Text CHANNEL TRANSITION SHALL BE CONSISTENT FROM INLET TO OUTLET OF MANHOLE TO FACILITATE SMOOTH TRANSITIONS AND ACCOMMODATE CORRESPONDING MANDREL.

AutoCAD SHX Text

%%USECTION A-A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text

%%UTYPICAL CHANNEL

AutoCAD SHX Text

TOP OF SHELF TO TOP OF PIPE (MIN 2% SLOPE) NOT TO EXCEED 3"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

90° MIN ANGLE

AutoCAD SHX Text

2"± RADIUS

90° MIN ANGLE

AutoCAD SHX Text

CHANNEL, FORMED WITH PRECAST AND CAST IN PLACE BASE, (TYP).

AutoCAD SHX Text

OUTLET PIPE PER APPROVED PLANS

AutoCAD SHX Text

OUTLET PIPE PER APPROVED PLANS

AutoCAD SHX Text

SEE DETAIL 7, ON THIS SHEET FOR NOTES

FLOW

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

FLOW

AutoCAD SHX Text

PROVIDE A ±12 INCHTANGENT AT ALL PIPE CONNECTIONS (TYP)

2"± RADIUS

10/1/2020 Property Inquiry parcelsearch.co.santa-cruz.az.us/RWDataMartPropertyInquiry/ParcelDetail.aspx?a=6018e511-3414-4365-9534-6f565a55ed13 1/2

Property Records Inquiry

Revise Search Print This Page

General Information 2021

Property Address Owner Name & Address

9 OJO CT

RIO RICO, 85648

Primary Owner

DELTA PROPERTIES L L P

ARIZONA LIMITED LIABILITY PARTNERSHIP

P O BOX 1806

NOGALES, AZ 85628

100.00%

Legal Description

Subdivision: RIO RICO SOUTH INDUSTRIAL PARK Lot: 5 LESS WLY PORT Block:

Section: 12, Township: 23S, Range: 13E

Extended Legal: SUB RIO RICO SOUTH INDUSTRIAL PARK LOT 5 EXCEPT THE WESTERLY PORTION

Property Information

Parcel Number: 14001005 Account Number: R000040116

Tax District: 3502 Current Mill Levy: 0

Square Feet: 109,335.60 Total Acres: 2.51

Primary Use Description: 3020-MANUF,DUR/NONDUR GDS

Sales Information

Reception # Sale Price Deed Type SaleDate Grantor Grantee

19880888787 $300,000 OTHER 12/20/1988 DILA INVESTMENT CORP. MANTA PROPERTIES, PARTNERSHIP

Value Information Approach: Assr Ovrd

Abstract Code/Description Value Type Appraised Value Assessed Value Taxable Value

0112I Commercial / Real and Improvements Improvement $165,184 $29,733 $29,733

0112L Commercial / Real and Improvements Land $218,671 $39,361 $39,361

Totals: $383,855 $69,094 $69,094

Limited Property Value (LPV)

Abstract Code/Description Value Type LPV Actual LPV Assessed LPV Taxable Value

0112I Commercial / Real and Improvements Improvement $165,184 $29,733 $29,733

0112L Commercial / Real and Improvements Land $218,671 $39,361 $39,361

Totals: $383,855 $69,094 $69,094

Account Flags

Flag Type Flag Description Unit Count

Property Attributes & Descriptions

Attribute Attribute Description

The Parcel has the following Exemptions:

A2 Physically Unchanged Improvement

Building ID 1.00

Occupancy Description Storage Warehouse Rooms 0

Built As Storage Warehouse Bedrooms 0

Exterior Baths 0

HVAC Space Heater Year Built 1972

PARCEL 140-01-005 EXHIBIT 2

http://parcelsearch.co.santa-cruz.az.us/RWDataMartPropertyInquiry/Inquiry.aspx http://parcelsearch.co.santa-cruz.az.us/RWDataMartPropertyInquiry/Inquiry.aspx javascript:window.print() http://parcelsearch.co.santa-cruz.az.us/RWDataMartPropertyInquiry/PhotoViewer.aspx?ViewType=full&i=42db7991-39ea-4595-8ffa-ab682662c536 http://parcelsearch.co.santa-cruz.az.us/RWDataMartPropertyInquiry/PhotoViewer.aspx?ViewType=full&i=c0a90a71-4c9d-4668-99fc-d6bced1da405

10/1/2020 Property Inquiry parcelsearch.co.santa-cruz.az.us/RWDataMartPropertyInquiry/ParcelDetail.aspx?a=6018e511-3414-4365-9534-6f565a55ed13 2/2

[BuildingImage]

Detail Type Detail Description Units

Add On PAVING, ASPHALT - PAS 17276.0000

Add On Docks Height Floors - DOF 15120.0000

Add On Landscape, Desert/Grass - LAM 1034.0000

Add On Loading Well, Single - DLX 1.0000

Add On PAVING, CONCRETE - PCO 1106.0000

Building ID 2.00 Occupancy Description Shed - Equipment Rooms 0

Built As Shed - Equipment Bedrooms 0

Exterior Baths 0

HVAC None Year Built 1972

[BuildingImage]

Building ID 3.00

Occupancy Description Storage Warehouse Rooms 0

Built As Storage Warehouse Bedrooms 0

Exterior Baths 0

HVAC Space Heater Year Built 1978

[BuildingImage]

Detail Type Detail Description Units

Add On Docks Height Floors - DOF 5040.0000

Add On Loading Dock without Roof - DLW 256.0000

<< Return to Results

PARCEL 140-01-005 EXHIBIT 2

http://parcelsearch.co.santa-cruz.az.us/RWDataMartPropertyInquiry/PhotoViewer.aspx?ViewType=full&i=38d883d3-719e-4ca6-9beb-d964e07f848c http://parcelsearch.co.santa-cruz.az.us/RWDataMartPropertyInquiry/PhotoViewer.aspx?ViewType=full&i=136a7de9-3ea5-4d15-9ffc-208f7fb4d353 ra w n by

D es ig ne d by

R ev ie w ed b y:

D at e:

S ub m itt ed b y:

D es cr ip tio n

D at e A ct io n

S ol ic ita tio n

N o.

C on tr ac t N o.

R ev

Sheet Reference Number:

F ile

N am e:

P lo t D at e:

P lo t S ca le

S ym bo l

L:

\A

G E

\P ro je ct s\

IN

F R

\ib w c\

IB

W C

E ng in ee rin g

S er vi ce s\ T as k

O rd er

IB

M

T

N og al es

IO

I\0

8- D ra w in gs

\P ha se

D es ig n\

P la n S he et s\

-G C

S H

E E

T S

\I- G

C -1

1-

.d lo tte d:

W ed ne sd ay , A pr il

, 2

:2

6:

A M

T ra ck in g N o.

/2 6/

I- G

C -1

1-

.d w g

R E

H A

B

IL

IT

A

T

IO

N

IM

P R

O V

E M

E N

T S

T R

U N

K

LI

N E

A N

D

IN

T E

R N

A T

IO

N

A L

O U

T F

A

LL

IN

T

E R

C E

P T

O R

, S A

N T

A C

R U

Z C

O U

N T

Y , A

Z P

H A

S E

I

P R

O

JE

C T

N O

. 4

U R

S C

O R

P O

R A

T

IO

N

E

A S

T W

E T

M O

R E

R O

A D

S

U

IT

E

T

U C

S O

N , A

Z

(5

7-

U .S

. I N

T E

R N

A T

IO

N

A L

B O

U N

D A

R Y

W

A T

E R

C O

M M

IS

S

IO

N

N O

G A

LE

S

, A Z

IB

M

D

S

LS

S

LS

T S

S

C H

A R

LE

S

P E

D R

I, P

.E

/3

0/

N O

T T

O S

C A

LE

I-GC-1002

G E

N E

R A

L A

R R

A N

G E

M E

N T

P

LA

N S

H E

E T

O

F

MH #96

MH #97

MH #97-A

MH #97-B

MH #98

255253

M A

T C

H L

IN

E

S T

A

UNION PACIFIC NOGALES BRANCH RR

WASTEWATER

TREATMENT

PLANT

RR ROW

RR ROW

MH #95

253251249

M A

T C

H L

IN

E

S T

A

UNION PACIFIC NOGALES BRANCH RR

RR ROW

M A

T C

H L

IN

E

S T

A

RR ROW

RR ROW

RR ROW

PHASE I PROJECT

END BYPASS PIPING

WWTP

POTRERO CREEK

POTRERO CREEK

POTRERO CREEK

POTRERO CREEK

MH #94

PHASE I PROJECT

END CIPP PIPING

CL MH # 99

STA 464+36.39

N=162940.08 E=997040.68

HORIZONTAL

HORIZONTAL

247245

ID NUMBER APN NUMBER

APN NUMBERS TABLE

ID NUMBER APN NUMBER

149 105-07-006

243 112-43-001C

245 140-01-001A

247 140-01-005

249 140-01-006A

251 140-01-008

253 140-01-010

255 140-01-012A

257 140-01-012B

259 140-01-013

263 140-01-038B

LEGEND

PROPOSED CURED IN PLACE PIPE

PROPOSED BYPASS PIPE LINE

PROPOSED TRUNKLINE AND IOI

PIPE LINE EASEMENT

EXISTING STORM SEWER MAIN

EXISTING RAILROAD RIGHT OF WAY

EXISTING PARCEL LINE

EXISTING STORM MANHOLE

PL

BYP

PLE

SSx

RR ROW

(SEE NOTE 3)

NOTES:

1. PARCEL DATA PROVIDED BY GEOGRAPHIC MAPPING APPLICATION

AND SANTA CRUZ COUNTY GIS. PARCEL BOUNDARIES ARE

APPROXIMATE. HORIZONTAL COORDINATES: NAD83.

2. THE AERIAL IMAGE MAY NOT REFLECT EXISTING CONDITIONS AND

IS SHOWN FOR INFORMATION PURPOSES ONLY. THE CONTRACTOR

SHALL VISIT THE SITE PRIOR TO BIDDING TO FAMILIARIZE HIMSELF

WITH THE PROJECT AREA.

3. USE ID NUMBERS SHOWN ON MAPS TO FIND CORRESPONDING

APN NUMBER IN TABLE. APN NUMBERS CAN BE ENTERED AT THE

FOLLOWING WEBSITE TO FIND PARCEL OWNERSHIP INFORMATION:

https://gis.santacruzcountyaz.gov/asr/index.html

NOTE THAT THE APN NUMBER MUST BE ENTERED INTO THE

WEBSITE WITHOUT ANY DASHES.

4. SEE SHEET I-GI-0002 FOR ABBREVIATIONS.

5. SEE SHEET I-GI-0003 FOR GENERAL NOTES.

PARCEL 140-01-005 EXHIBIT 3

Delta Properties 9 Ojo Ct.

ra w n by

D es ig ne d by

R ev ie w ed b y:

D at e:

S ub m itt ed b y:

D es cr ip tio n

D at e A ct io n

S ol ic ita tio n

N o.

C on tr ac t N o.

R ev

Sheet Reference Number:

F ile

N am e:

P lo t D at e:

P lo t S ca le

S ym bo l

L:

\A

G E

\P ro je ct s\

IN

F R

\ib w c\

IB

W C

E ng in ee rin g

S er vi ce s\ T as k

O rd er

IB

M

T

N og al es

IO

I\0

8- D ra w in gs

\P ha se

D es ig n\

P la n S he et s\

-G C

S H

E E

T S

\I- G

C -1

1-

.d tte d:

W ed ne sd ay , A pr il

, 2

:2

6:

A M

T ra ck in g N o.

/2 6/

I- G

C -1

1-

.d w g

R E

H A

B

IL

IT

A

T

IO

N

IM

P R

O V

E M

E N

T S

T R

U N

K

LI

N E

A N

D

IN

T E

R N

A T

IO

N

A L

O U

T F

A

LL

IN

T

E R

C E

P T

O R

, S A

N T

A C

R U

Z C

O U

N T

Y , A

Z P

H A

S E

I

P R

O

JE

C T

N O

. 4

U R

S C

O R

P O

R A

T

IO

N

E

A S

T W

E T

M O

R E

R O

A D

S

U

IT

E

T

U C

S O

N , A

Z

(5

7-

U .S

. I N

T E

R N

A T

IO

N

A L

B O

U N

D A

R Y

W

A T

E R

C O

M M

IS

S

IO

N

N O

G A

LE

S

, A Z

IB

M

D

S

LS

S

LS

T S

S

C H

A R

LE

S

P E

D R

I, P

.E

/3

0/

N O

T T

O S

C A

LE

I-GC-1002

G E

N E

R A

L A

R R

A N

G E

M E

N T

P

LA

N S

H E

E T

O

F

MH #96

MH #97

MH #97-A

MH #97-B

MH #98

255253

M A

T C

H L

IN

E

S T

A

UNION PACIFIC NOGALES BRANCH RR

WASTEWATER

TREATMENT

PLANT

RR ROW

RR ROW

MH #95

253251249

M A

T C

H L

IN

E

S T

A

UNION PACIFIC NOGALES BRANCH RR

RR ROW

M A

T C

H L

IN

E

S T

A

RR ROW

RR ROW

RR ROW

PHASE I PROJECT

END BYPASS PIPING

WWTP

POTRERO CREEK

POTRERO CREEK

POTRERO CREEK

POTRERO CREEK

MH #94

PHASE I PROJECT

END CIPP PIPING

CL MH # 99

STA 464+36.39

N=162940.08 E=997040.68

HORIZONTAL

HORIZONTAL

247245

ID NUMBER APN NUMBER

APN NUMBERS TABLE

ID NUMBER APN NUMBER

149 105-07-006

243 112-43-001C

245 140-01-001A

247 140-01-005

249 140-01-006A

251 140-01-008

253 140-01-010

255 140-01-012A

257 140-01-012B

259 140-01-013

263 140-01-038B

LEGEND

PROPOSED CURED IN PLACE PIPE

PROPOSED BYPASS PIPE LINE

PROPOSED TRUNKLINE AND IOI

PIPE LINE EASEMENT

EXISTING STORM SEWER MAIN

EXISTING RAILROAD RIGHT OF WAY

EXISTING PARCEL LINE

EXISTING STORM MANHOLE

PL

BYP

PLE

SSx

RR ROW

(SEE NOTE 3)

NOTES:

1. PARCEL DATA PROVIDED BY GEOGRAPHIC MAPPING APPLICATION

AND SANTA CRUZ COUNTY GIS. PARCEL BOUNDARIES ARE

APPROXIMATE. HORIZONTAL COORDINATES: NAD83.

2. THE AERIAL IMAGE MAY NOT REFLECT EXISTING CONDITIONS AND

IS SHOWN FOR INFORMATION PURPOSES ONLY. THE CONTRACTOR

SHALL VISIT THE SITE PRIOR TO BIDDING TO FAMILIARIZE HIMSELF

WITH THE PROJECT AREA.

3. USE ID NUMBERS SHOWN ON MAPS TO FIND CORRESPONDING

APN NUMBER IN TABLE. APN NUMBERS CAN BE ENTERED AT THE

FOLLOWING WEBSITE TO FIND PARCEL OWNERSHIP INFORMATION:

https://gis.santacruzcountyaz.gov/asr/index.html

NOTE THAT THE APN NUMBER MUST BE ENTERED INTO THE

WEBSITE WITHOUT ANY DASHES.

4. SEE SHEET I-GI-0002 FOR ABBREVIATIONS.

5. SEE SHEET I-GI-0003 FOR GENERAL NOTES.

PARCEL 140-01-005 EXHIBIT 4

Requested temporary easement location

Existing City of Nogales sewer pipeline easement

Delta Properties 9 Ojo Ct.

422+00 423+00 424+00 425+00 426+00 427+00 428+00 429+00 430+00 431+00 432+00 433+00

XXX

X

SSx SSx

SSx SSx

SSx SSx

SSx SSx

SSx SSx

SSx SSx

SSx SSx

SSx SSx

SS

BYP BYP BYP BYP BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP

BYP BYP

BYP

BYP

B Y

P

B Y

P

B Y

P

BYP

BYP

BYP

BYP

PLAN

STA. 421+50.00 TO STA. 433+00.00

M A

T C

H L

IN

E

A T

S T

A T

IO

N

D ra w n by

D es ig ne d by

R ev ie w ed b y:

D at e:

S ub m itt ed b y:

D es cr ip tio n

D at e A ct io n

S ol ic ita tio n

N o.

C on tr ac t N o.

R ev

Sheet Reference Number:

F ile

N am e:

P lo t D at e:

P lo t S ca le

S ym bo l

L:

\A

G E

\P ro je ct s\

IN

F R

\ib w c\

IB

W C

E ng in ee rin g

S er vi ce s\ T as k

O rd er

IB

M

T

N og al es

IO

I\0

8- D ra w in gs

\P ha se

D es ig n\

P la n S he et s\

-G C

S H

E E

T S

\I- G

C -1

4-

.d tte d:

W ed ne sd ay , A pr il

, 2

:2

8:

A M

T ra ck in g N o.

/2 6/

I- G

C -1

4-

.d w g

R E

H A

B

IL

IT

A

T

IO

N

IM

P R

O V

E M

E N

T S

T R

U N

K

LI

N E

A N

D

IN

T E

R N

A T

IO

N

A L

O U

T F

A

LL

IN

T

E R

C E

P T

O R

, S A

N T

A C

R U

Z C

O U

N T

Y , A

Z P

H A

S E

I

P R

O

JE

C T

N O

. 4

U R

S C

O R

P O

R A

T

IO

N

E

A S

T W

E T

M O

R E

R O

A D

S

U

IT

E

T

U C

S O

N , A

Z

(5

7-

U .S

. I N

T E

R N

A T

IO

N

A L

B O

U N

D A

R Y

W

A T

E R

C O

M M

IS

S

IO

N

N O

G A

LE

S

, A Z

IB

M

D

S

LS

S

LS

T S

S

C H

A R

LE

S

P E

D R

I, P

.E

/3

0/

N O

T T

O S

C A

LE

CL UNION PACIFIC NOGALES BRANCH (200' R.O.W.)

R.R. R.O.W.

POTENTIAL BYPASS

PIPELINE ALIGNMENT

PIPELINE EASEMENT

N 15°- 57'- 16" W L = 411.18'

S 15°- 57'- 16" E

L = 416.66'

I-GC-1005

EXISTING 1177.6 LF 30" RCP

CL MH 94

STA = 429+05.16

N=159698.75 E=997635.32

R.R. R.O.W.

R.R. R.O.W.

R.R. R.O.W.

EXISTING 1162.9 LF 30" RCP

POTRERO CREEK

N 31°- 33'- 25" W

L = 402.89'

N 26°- 03'- 20" W

L = 351.40'

N 01°- 24'- 32" WL = 123.67'

N 33°- 28'- 38" W

L = 170.69'

S 31°- 33'- 25" E

L = 408.37'

S

1°

W

L

.7 0'

S 18°- 53'- 35" E

L = 562.95'

N 68°- 35'- 30" W L = 20.22'

40'

40'

40'

20' 20'

20' 20' 40'

TCE T-2

HORIZONTAL

PIPELINE EASEMENT

40' WIDE EASEMENT

T E

M P

O R

A R

Y C

O N

S T

R U

C T

IO

N

E A

S E

M E

H

E E

T

O F

NOTES:

1. SEE SHEET I-GI-0002 FOR LEGEND AND ABBREVIATIONS.

2. SEE SHEET I-GI-0003 FOR GENERAL NOTES.

T -2

PARCEL 140-01-005 EXHIBIT 4

Existing City of Nogales sewer pipeline easement

Delta Properties 9 Ojo Ct.

427+00 428+00428 0028 00 429+00429+00 430+00+0 431+004331+ 432+0043 433+00

SSx SSSSSSSSSx

SSSSSSSSSSx SSSSSSSSxxx

SSSSSSSSSSSxxx SSSSSSSxx

SSSSSSSSSSSSx SSSSSSx

SSSSSSSSSSx

SSSSS

BYPYP

B

R.R. R.O.W..O.W. R.

S 18°- 53'- 35" EE35" 53'- S 18 E55

L = 562.95'L =L = 5 55 20' 20'

20' 20' 4040'

40'

SS

BY

Requested temporary easement location

BYP

B Y

P

B Y

P

B Y

P

BYP

BYPYPYP

3.67'

L = 170.69'

N 68°- 35'- 30" W5 - 30N 68°- 35'- 30" W L = 20.22'L = 20 22

USIBWC TCE Parcel 140-01-005
Exhibit 1_Parcel ID 140-01-005 Delta Properties
Exhibit 2_Parcel ID 140-01-005 Delta Properties_Rev
Exhibit 3_Parcel 140-01-005_ID 247_Rev
Exhibit 4_Parcel 140-01-005_ID 247
Enclosure 1 Arizona Affidavit

File details come from the government source that posted it. Updated .