USIBWC TCE Parcel 102-01-076A_Sainz_Final.pdf
PDF 4 MB Posted
- Attached to
- Trunkline and IOI Rehabilitation Phases 1-3
- Solicitation number
- 191BWC21R0002
About this file
This solicitation seeks proposals for the rehabilitation of approximately 19,730 linear feet of sewer pipeline known as the Trunkline and International Outfall Interceptor in Nogales, Arizona, with an option to rehabilitate an additional 8,634 linear feet. Work will include cured-in-place pipe lining, manhole rehabilitation, and other repairs. Proposals are due by February 18, 2022. The agency, the International Boundary and Water Commission U.S.-Mexico, will award a firm fixed-price contract for the work in three phases to be completed by 2025.
View the file
Other files
Show 40 more
Latest 50 of 71 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
When recorded, return to:
United States International Boundary and Water Commission
ESD
Crystal Cadillo/Ariana Leos 4191 N. Mesa St.
El Paso, TX 79902
Guadalupe Sainz 356 Via Bella Donna Rio Rico, Arizona 85648
PROPERTY ADDRESS: 1982 N. Smokey Lane, Nogales, Arizona 85621
PARCEL NUMBER: 102-01-076A
PIPELINE REPAIRS ACCESS AGREEMENT
This Pipeline Repairs Access Agreement ("Agreement") is entered into by and between the United States International Boundary and Water Commission ("USIBWC") and Sainz Family Registered LLP, a(n) Arizona Limited Liability Partnership ("Owner"). USIBWC and Owner are referred to herein as the "Parties."
RECITALS
A. USIBWC operates and jointly owns with the City of Nogales the Nogales
International Wastewater Treatment Plant ("Plant"), located in Rio Rico, Arizona. The Plant is designed to treat to secondary standards wastewater from the cities of Nogales, Arizona, and Nogales, Sonora. Wastewater is conveyed to the Plant through a sewer pipeline ("Pipeline"). The Pipeline is a continuous sewer pipeline located in Nogales, Arizona, that extends roughly nine miles from the United States-Mexico international boundary line to the Plant and carries approximately 15 million gallons of sewage each day to the Plant. The Pipeline requires rehabilitation due to age, lack of maintenance, and increasing demand for wastewater management. USIBWC has developed plans and specifications for the repair and rehabilitation of the Pipeline ("Repairs"), which will be provided to Owner upon request.
Attached hereto as "Exhibit 1" is(are) the applicable plan(s) of work at the property address.
B. In order to make the necessary Repairs, USIBWC requires access to 1982 N.
Smokey Lane, Nogales, Arizona ("Property"). The Owner’s deed/property information is attached setting forth the legal description of the Property and marked "Exhibit 2." The location of the Property is shown by the Map that is attached and marked "Exhibit 3." The Property’s tax parcel number is 102- 01-076A.
C. The Parties desire to state the terms upon which the USIBWC may enter upon the Property and make Repairs. Attached hereto as "Exhibit 4" is the area and location of the temporary construction easement (TCE) requested within the Property.
AGREEMENT
The Parties covenant and agree as follows:
1. Recitals and Warranty of Title. The Recitals and Exhibits are a material part of this Agreement. Owner holds equitable and legal title to and exclusive possession of the Property. Owner has the authority to enter into this Agreement and represents that there is no tenant or other person currently in possession of the Property. The USIBWC has conferred with the Owner and, insofar as a tenant is in possession of the Property, the Owner has informed the USIBWC that the Owner will coordinate and inform the tenant(s) of the access, but no additional agreement is required with the tenant(s). The Owner has provided an affidavit or letter confirming their responsibility to coordinate/inform their tenants of this agreement, attached and marked as "Enclosure 1."
2. Repair Costs. USIBWC shall bear the cost of Repairs.
3. Grant of Right of Access. Owner grants an easement to USIBWC and its representatives, contractors, and any authorized agents to enter on, use, and occupy the Property for the purpose of conducting Repairs. This Agreement is a covenant running with the land, binds Owner and Owner’s heirs, successors, tenants, and assigns, and will terminate only when UISBWC determines that the Repairs are completed or should be discontinued and records a document expressly terminating this Agreement. USIBWC may record this Agreement in the county where the Property is located.
4. Duty of Care. Owner and Owner’s agents, employees, contractors, tenants, invitees, and guests shall not hinder or interfere with the Repairs and shall not damage or tamper with any equipment or other property used in connection with the Repairs. The USIBWC and its contractors shall not obstruct or block the Owner's and Owner's agents', employees', contractors', tenants', invitees', and guests' access to the property.
5. Prior Notice of Activities and Contractor Work. The USIBWC's contractors will use reasonable efforts to give Owner at least thirty (30) calendar days prior notice of entry onto the Property for Repairs on the Pipeline. USIBWC's contractors shall provide a work plan to the Owner at the time of notice including the following information:
a. Contractor's point of contact for the Owner that is available 24 hours/7 days a week;
b. Proposed start date and duration of contractor's work within property;
c. Description of the equipment and/or materials to be temporarily placed/installed temporarily on the Property;
d. Description of the construction work to be performed within the
Property, if applicable; and,
e. Drawing showing the specific limits and size of area within Property to be used and layout of the proposed temporary equipment and/or materials to be used within the area, such as the bypass system.
The Owner shall notify the USIBWC's contractor point of contact within seven (7) calendar days of receiving notice of entry if the Owner identifies that the contractor's proposed layout of temporary equipment and/or materials to be installed within the property will result in obstruction of access to the property by the Owner or Owner's tenant.
6. Notices Required Under This Agreement.
Notices from USIBWC or its contractors to Owner shall be effective when given, if by telephone, to:
Guadalupe Sainz at (520) 980-7336, and, if in writing, to:
Sainz Family Registered LLP Guadalupe Sainz 356 Via Bella Donna Rio Rico, Arizona 85648
Notices from Owner to USIBWC shall be effective when given, if by telephone or email, to:
Crystal Cadillo
(915) 832-4159 crystal.cadillo@ibwc.gov
OR
Ariana Leos
(915) 832-4168 ariana.leos@ibwc.gov and, if in writing, to:
Attention:
USIBWC-ESD
Crystal Cadillo/Ariana Leos 4191 N. Mesa St.
El Paso, TX 79902
If Owner changes its telephone number or mailing address for purposes of notice under this Agreement, written notice of the change shall be promptly given to USIBWC. If this Agreement requires notices to be provided in writing, telephonic notice will not suffice as notice.
7. Insurance. While this Agreement is in effect, the USIBWC remains self-insured under the Federal Tort Claims Act as an instrumentality of the Federal Government and will require its contractors to comply with the insurance provisions of the construction Contract requiring liability insurance.
8. No Indemnity. Owner and USIBWC or its contractors are responsible for only their own negligence in connection with the Repairs conducted on the Property. Neither Party to this Agreement agrees to indemnify the other Party or hold harmless the other Party from liability hereunder.
9. Damage to Property. USIBWC's contractors will repair any material damage it causes to the Property. All areas utilized and/or disturbed by USIBWC's contractors within the Owner's property shall be restored by the contractor to preconstruction conditions. If Owner or its tenant intentionally or negligently damages the property of the USIBWC or its contractor, then the Owner or its tenants will repair any material damage caused. Existing remedies at law are available to seek compensation or remedy for any damage caused should either party fail to make repairs.
10. Default. Notices of default must be provided in writing. If either Party defaults under this Agreement and the default continues for more than ten (10) days after the effective date of the Party’s written notice stating the specific nature of the default, then the Party may treat the default as a breach of this Agreement.
Notwithstanding the foregoing, in the event Owner notifies USIBWC of a default, if U$IBWC determines that the default cannot be cured within the ten-day notice period, then the default shall be deemed cured if USIBWC commences efforts to cure the default within the ten-day notice period. A default is a violation of any term of this agreement. USIBWC’s or its contractor’s failure to give notice under Paragraph 5 also constitutes a default under this Agreement. Owner’s failure to provide access under this Agreement is not subject to the ten-day notice period and is an immediate breach of this Agreement.
11. Dispute Resolution. The Parties shall resolve any breach or dispute arising out of this Agreement by arbitration. Proper venue for any civil action, proceeding, or arbitration arising out of this Agreement shall be the United States District Court for Southern Arizona.
12. Exhibits to this Agreement. Exhibits to this Agreement are intended for informational purposes. If there is a conflict between the terms of this Agreement and an Exhibit to this Agreement, the terms of this Agreement shall control.
13. Miscellaneous. (A) This Agreement expresses the entire agreement of the Parties; (B) Owner agrees that Owner is not relying on any promise, agreement, or representation made by USIBWC except as stated in this Agreement;
(C) no modification of this Agreement is valid or enforceable unless the terms of the modification are in writing and signed by the Parties; (D) this Agreement binds and inures to the benefit of the Parties and their agents, heirs, successors, assigns, transferees, executors, and personal representatives; (E) USIBWC shall retain possession of the fully executed original of this Agreement and Owner shall receive exact copies; (F) this Agreement is effective when signed by the Parties; (G) this Agreement is subject to available ftinding and nothing shall bind USIBWC to expenditures in excess of funds appropriated and allotted for the purposes in this Agreement; (H) this Agreement shall be interpreted and enforced according to Federal law and, when no federal law applies, then the laws of the State of Arizona;
and, (I) this Agreement may be signed in counterparts, each of which shall be treated as an original but which, when taken together, shall constitute one and the same Instrument.
Sainz Family Registered LLP, an Arizona limited liability partnership, Grantor
77 / /By I[signature of managing partner]
DANIEL AVILA Digitally signed by DANIEL AVILA Date: 2021.03.30 14:55:10 -06'00'
Daniel Avila, Acting Commissioner
3/30/2021
COCHISE
LOCATION OF WORK
PIMA
GRAHAM
PINAL
SANTA
CRUZ
GILA
G R
E E
N L
E E
NAVAJO
APACHE
COCONINO
YAVAPAI
MARICOPA
YUMA
LA PAZ
MOHAVE
A R I Z O N A
UTAH
CALIFORNIA
MEXICO
NEW
MEXICO
NEVADA
333 EAST WETMORE ROAD,
SUITE 400, TUCSON, AZ 85705
(520) 887-1800
PROJECT NET LENGTH : 1.56 MI
U.S. INTERNATIONAL BOUNDARY AND
WATER COMMISSION
NOGALES, AZ
WASTEWATER
TREATMENT
PLANT
C o n t r
N o
I B
M
T
III-GI-0001
PROJECT VICINITY MAP
PROJECT LOCATION MAP
L A
G E
P r o j e c t s I N
F R i b w c I B
W C
E n g i n e e r i n g
S e r v i c e s T a s k
O r d e r
I B
M
T
N o g a l e s
I O
I
D r a w i n g s P h a s e
D s i i g n P l a n
S h e e t s
G
I
S
H E
E T
S I B
M
T
I I I G
I d w g
P l o t t e d
W e d n e s d a y
M a y
A
M
NOGALES
A
Z
R
U
B
Y
O L D
T U
C S
O N
R
N
M
R
I
P
O
S
G
A
V
E
C
E
R
R
A
O
N
C
H
E
Z
P
E
N
D
L
E
T
K
IP
P E
R S
T
O
L
T
A
G
O
N
I
H
Y
T
U
C
S
O
N
N
O
G
A
L
E
S
H
W
Y
A
V
P
A
S
E
B
A
B
D
U
S
T
R
I
K
F
A
K
B
L
V
I
D
U
N
I
C
I F
I C
R
R
U N
IO
C
IF
IC
.R
M
E
X
I C
O U
N
I T
T
A
T
E
S
I N
T
E
R
N
A
T
I O
N
U
N
D
A
R
Y
NOGALES
Sheet
Reference
Number:
CONTRACT NO: IBM09D0008
ORDER NO: IBM14T0007
SURVEY CONTROL
HORIZONTAL CONTROL IS BASED ON ARIZONA STATE
PLANE, CENTRAL ZONE, NORTH AMERICAN DATUM OF
1983 (NAD 83). VERTICAL CONTROL IS BASED ON NORTH
AMERICAN VERTICAL DATUM OF 1988 (NAVD 88).
NOT TO SCALE
NOT TO SCALE
NOGALES TOWNSITE
SECTION 17, RANGE 14 EAST,
TOWNSHIP 24 SOUTH GILA AND SALT
RIVER BASE AND MERIDIAN (G& SRB & M)
SANTA CRUZ COUNTY, ARIZONA
LATITUDE: 31° 19' 50.38" N
LONGITUDE: 110° 56' 30.84" W
PHASE III PROJECT
END CIPP PIPING
CL MH #51
STA 198+73.10
N = 139123.56
E = 1004918.40
PHASE III PROJECT
BEGIN CIPP PIPING
CL MH #37
STA 112+39.39
N = 131838.51
E = 1008203.91
PHASE III
ARIZONA
SANTA CRUZ
COUNTY
NOGALES
UNITED STATES INTERNATIONAL
BOUNDARY AND WATER COMMISSION
REHABILITATION IMPROVEMENTS
TRUNKLINE AND INTERNATIONAL OUTFALL INTERCEPTOR
SANTA CRUZ COUNTY, AZ
PHASE III
T
R
U
N
K
L
I N
E
I O
I
SAN
TA C
R U
Z
C
IT
Y O F
N O
G
ALES
C O
U N
TY
STA 81+46
Solicitation No. 191BWC21R0002
PARCEL 102-01-076A EXHIBIT 1
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text
AutoCAD SHX Text r a b y
D e s i g n e d b y
R e v i e w e d b y
D a t e
S u b m i t t e d b y
D e s c r i p t i o n
D a t e
A c t i o n
S o l i c i t a t i o n
N o
C o n t r a c t
N o
R e v
Sheet
Reference
Number:
F i l e
N a m e
P l o t
D a t e
P l o t
S c a l e
S y m b o l
L A
G E
P r o j e c t s I N
F R i b w c I B g i n e e r i n g
S e r v i c e s T a s k
O r d e r
I B
M
T
N o g a l e s
I O
I
D r a w i n g s P h a s i i g n P l a n
S h e e t s
G
I
S
H E
E T
S I B
M
T
I I I G
I d o t t e d
W e d n e s d a y
M a y
A
M
T r a c k i n g
N o
I B
M T
I I I G
I d w g
P R
O J E
U R
S
C
O R
P O
R A
T I O
N
E
A S
T
W
E T
M O
A
D
S U
I T
E
C
S O
N
A
Z
U S
I N
T E
R N
A T
I O
N A
L
B
O U
N D
A R
Y
W A
T E
R
C
O M
M I S
S I O
N
N O
G A
L E
S
A
Z
S L
S
S L
S
T S
S
C H
A R
L E
S
P
E D
R I
P
E
T
E D
R E
H A
B I L
I T
A T
I O
N
I M
P R
O V
E M
E N
T S
T R
U N
K L
I N
E
A
T E
R N
A T
I O
N A
L
O
U T
F A
L L
I N
T E
R C
E P
T O
R
S
A N
U
Z
C
O U
N T
Y
A
Z
P H
A S
E
I I I
III-GI-0004
R E
Q U
I R
N
H O
H
A B
I L
I T
A T
I O
N
REQUIRED MANHOLE REHABILITATION TABLE
MH NUMBER STATION RIM ELEVATION INVERT ELEVATION
PIPE DIAMETER
(INCHES)
MANHOLE
DEPTH (FEET)
PROTECTIVE
LINER
SYSTEM
HYDRAULIC
WATER PLUG
CARBON
FIBER
COMPOSITE
RAISE
MANHOLE
TO GRADE
APPLICABLE
DETAILS
(SHEET III-CU-3001/III-CU-3002)
REQUIRED MANHOLE REHABILITATION
X39 123+16.64 3762.98 3751.02 30 11.96
X
X8.70
X
X9.08
X
X8.12
X9.35
X9.97
11.37
X
8.75
X
9.64
X
10.33
X11.34
X
X13.05
X11.77
X
X10.46
X
X10.12
X7.10
X7.13
X
X
X
X
X
X
40 131+81.48
41 133+21.27
42 137+06.54
43 137+99.61
44 142+00.78
44-A1 144+42.45
44-A 147+91.14
44-B 149+91.66
44-C 151+46.69
45 154+65.58
46 156+66.70
47 160+21.73
48 172+68.63
49 175+62.00
50 189+72.02
51 198+73.10
3753.33 3744.63
3752.69 3743.61
3749.20 3741.08
3749.64 3740.29
3747.70 3737.73
3747.19 3735.82
3742.40 3733.65
3741.86 3732.22
3741.51 3731.18
3739.95 3728.61
3740.63 3727.58
3736.86 3725.09
3727.01 3716.55
3724.87 3714.75
3712.00 3704.90
3705.94 3698.81
MANHOLE
DIAMETER
(FEET)
1,2,3
X
X
X38 116+35.83 3769.21 3755.41 30 13.80
X
IOI MANHOLE
CONNECTING LATERAL
LATERAL DIAMETER
(INCHES)
ESTIMATED LENGTH ALONG LATERAL TO NEXT
UPSTREAM MANHOLE (FEET) /
STATUS OF DIRECT LATERAL
UNKNOWN
ESTIMATED AVERAGE FLOW
(GPM)
UNKNOWN
UNKNOWN
UNKNOWN
LATERAL INFORMATION TABLE
41 UNKNOWN
44A1 UNKNOWN
44A UNKNOWN
44A UNKNOWN
44A UNKNOWN
44B UNKNOWN
44C UNKNOWN
44C UNKNOWN
45 NO NAME UNKNOWN
46 MARIPOSA UNKNOWN
46 NO NAME UNKNOWN
NOTES:
1. SEE DRAWINGS III-CU-2012 THRU III-CU-2020 FOR PLAN AND PROFILES.
2. SEE DRAWINGS III-CU-3001 AND III-CU-3002 FOR MANHOLE REHABILITATION
DETAILS (PROTECTIVE LINER SYSTEM AND CARBON FIBER COMPOSITE).
3. REHABILITATION WITH PROTECTIVE LINER SYSTEM REQUIRED FOR CONCRETE
MANHOLES IN EITHER GOOD OR FAIR CONDITIONS.
4. REHABILITATION WITH CARBON FIBER COMPOSITE REQUIRED FOR BRICK
MANHOLES AND CONCRETE MANHOLES IN POOR CONDITION.
5. ALL MANHOLES SHOWN IN TABLE ABOVE SHALL BE INCLUDED IN THIS PHASE
OF WORK.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR BYPASSING OF FLOWS FROM THE
LATERALS LISTED IN THE LATERAL INFORMATION TABLE ON THIS DRAWING.
7. CONTRACTOR SHALL TRIM ALL PROTRUSIONS FROM LATERALS DIRECTLY
CONNECTED TO THE IOI AND THE TRUNKLINE BEFORE INSTALLATION OF CIPP
47 BAFFERT
NO NAME
NO NAME
NO NAME
NO NAME
NO NAME
NO NAME
NO NAME
NO NAME
SONORA
NO NAME
NO NAME
NO NAME
NO NAME
NO NAME
NO NAME
UNKNOWN
UNKNOWN
UNKNOWN
UNKNOWN
UNKNOWN
12.2 LF
DOWNSTREAM
OF MH 39
UNKNOWN
NO NAME
150' (LATERAL NOT FOUND)
1,2,3
155.5 LF
DOWNSTREAM
OF MH 39
UNKNOWN
NO NAME
8 TO BE REROUTED TO MH 39 OR 40 BY OTHERS
37A 113+55.00 3773.40 3757.10 30 16.30 4
NEW MANHOLE NO
REHABILITATION REQUIRED
PARCEL 102-01-076A EXHIBIT 1
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text x
S
S x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
x
SS
W
W
W
G
S
W
143+00
144+00
145+00
146+00
147+00
148+00
149+00
150+00
151+00
152+00
C
B
X
X
L
N
O
R
L
N
O
R
A
S
S
W
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
E x
X
X X X
X
X
X
X
XX
N SMOKEY LN
P
A
R
K
I
T
PARKING LOT
N SMOKEY LN
PARKING LOT
SOIL BORING B-9
50' PIPE LINE EASEMENT
P
L
E
P
L
E
P
L
E
P
L
E
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
P
L
E
P
L
E
P
L
E
P
L
E
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
PLE
EXISTING 401.2 LF OF 30" RCP
TO BE REHABILITATED WITH
CURED IN PLACE PIPE LINER
EXISTING 241.7 LF OF 30" RCP
TO BE REHABILITATED WITH
CURED IN PLACE PIPE LINER
EXISTING 155.0 LF OF 30" RCP
TO BE REHABILITATED WITH
CURED IN PLACE PIPE LINER
EXISTING 200.5 LF OF 30" RCP
TO BE REHABILITATED WITH
CURED IN PLACE PIPE LINER
EXISTING 348.7 LF OF 30" RCP
TO BE REHABILITATED WITH
CURED IN PLACE PIPE LINER
B
Y
P
B
Y
P
B Y
P
BYP
BYP
BYP
BYP
BYP
BYP
B Y
P
B Y
P
B
Y
P
B
Y
P
B
Y
P
B
Y
P
B
Y
P
B
Y
P
B
Y
P
B
Y
P
B
Y
P
B
Y
P
B
Y
P
BYP BYP BYP
BYP BYP BYP BYP
B Y
P
B Y
P
BYP
BYP
BYP
EAST CALLE SONORA RD
CROSSING (SEE NOTE 1)
POTENTIAL BYPASS
PIPING ALIGNMENT
(SEE NOTE 2)
S
CL MH 44
STA = 142+00.78
N=134725.01
E=1008162.39
RIM: 3747.70
30" DIA. RCP PIPE
INV. EL.3737.73
(SEE NOTE 4)
S
CL MH 44-A1
STA = 144+42.45
N=134961.90
E=1008114.54
RIM: 3747.19
30" DIA. RCP PIPE, INV. EL.3735.82
8" DIA. DI PIPE, INV. EL.3739.58
(SEE NOTE 4)
S
CL MH 44-A
SSTA = 147+91.14
N=135303.46
E=1008044.36
RIM: 3742.40
30" DIA. RCP PIPE, INV. EL.3733.65
8" DIA. PVC PIPE, SE. INV. EL.3735.63
8" DIA. DI PIPE, NE. INV. EL.3736.76
8" DIA. PIPE, N. INV. EL.3737.05
(SEE NOTE 4)
S
CL MH 44-B
STA = 149+91.66
N=135499.88
E=1008004.09
RIM: 3741.86
30" DIA. RCP PIPE, INV. EL.3732.22
8" DIA. DI PIPE, E. INV. EL.3734.88
(SEE NOTE 4)
S
CL MH-44C
STA = 151+46.69
N=135651.54
E=1007971.94
RIM: 3741.51
30" DIA. RCP PIPE, INV. EL.3731.18
6" DIA. PIPE, NE. INV. EL.3733.77
6" DIA. PIPE, E. INV. EL.3734.01
(SEE NOTE 4)
P
A
V
E
D
S
S x
S
S x
S S x
S
S x
S S x
S
S x
M
A
T
A
T
I
M A
T C
H
L I N
E
A
T
S
T A
T I O
N
141+00
142+00
143+00
144+00
145+00
146+00
147+00
148+00
149+00
150+00
151+00
152+00
M H
N
O
S T
A
R
M H
N
O A
S T
A
M H
N
O A
S T
A
R
M H
N
O B
S T
A
R
M H
N
O C
S T
A
R
30" R C
P P
IP
E
S
0.0064
30" R C
P P
IP
E
S
0.0079
30" R C
P P
IP
E
S
0.0062
30" R C
P P
IP
E
S
0.0071
30" R C
P P
IP
E
S
0.0067
30" R C
P P
IP
E
S
0.0081
30" INV. EL.3731.18
30" INV. EL.3732.22
30" INV. EL.3733.65
30" INV. EL.3735.82
30" INV. EL.3737.73
EXISTING GROUND
8" INV. EL.3739.58
8" INV. EL.3735.63
8" INV. EL.3736.76
6" INV. EL.3733.77
6" INV. EL. 3734.01
8" INV. EL.3734.88
8" INV. EL.3737.05
EXISTING GROUND ELEVATION
AT PIPE CENTERLINE
M H
N
O A
S T
A
R
C
L
N
O R
A
PLAN
STA. 141+00.00 TO STA. 152+00.00
PROFILE
STA. 141+00.00 TO STA. 152+00.00
P L
O
F I L
E S
S T
A
T
O
S
T A
III-CU-2015
0 40' 80'
SCALE: 1" = 40'
20'
0 5' 10'
SCALE: 1" = 5'
VERTICAL
HORIZONTAL
M A
T C
H
L I N
E
A
T
S
T A
T I O
N
M
A
T
A
T
I
D r a
D e s i g n e d b y
R e v i e w e d b y
D a t e
S u b m i t t e d b y
D e s c r i p t i o n
D a t e
A c t i o n
S o l i c i t a t i o n
N o
C o n t r a c t
N o
R e v
Sheet
Reference
Number:
F i l e
N a m e
P l o t
D a t e
P l o t
S c a l e
S y m b o l
L A
G E
P r o j e c t s I N
F R i b w c I B g i n e e r i n g
S e r v i c e s T a s k
O r d e r
I B
M
T
N o g a l e s
I O
I
D r a w i n g s P h a s i i g n P l a n
S h e e t s
C
F S
H E
E T
S I B
M
T
I I I C
U d o t t e d
W e d n e s d a y
M a y
P
M
T r a c k i n g
N o
I B
M T
I I I C
U d w g
P R
O J E
U R
S
C
O R
P O
R A
T I O
N
E
A S
T
W
E T
M O
A
D
S U
I T
E
C
S O
N
A
Z
U S
I N
T E
R N
A T
I O
N A
L
B
O U
N D
A R
Y
W A
T E
R
C
O M
M I S
S I O
N
N O
G A
L E
S
A
Z
S L
S
S L
S
T S
S
C H
A R
L E
S
P
E D
R I
P
E
T
E D
R E
H A
B I L
I T
A T
I O
N
I M
P R
O V
E M
E N
T S
T R
U N
K L
I N
E
A
T E
R N
A T
I O
N A
L
O
U T
F A
L L
I N
T E
R C
E P
T O
R
S
A N
U
Z
C
O U
N T
Y
A
Z
P H
A S
E
I I I
PHASE III (CONT.)
NOTES:
1. CONTRACTOR SHALL INSTALL BYPASS PIPING BENEATH
E. CALLE SONORA IN ACCORDANCE WITH CITY OF NOGALES
REQUIREMENTS.
2. CONTRACTOR SHALL CONDUCT ALL WORK WITH IN
N. SMOKEY LANE ROW IN ACCORDANCE WITH CITY OF NOGALES
REQUIREMENTS.
PHASE III (CONT.)
4. SEE DETAIL 2, SHEET IV-CU-3001 FOR MANHOLE REHABILITATION.
3. SEE SPECIFICATION SECTION 46.04.00 FOR CURED-IN-PLACE PIPE
(CIPP) REQUIREMENTS.
4. SEE DETAIL 2, SHEET III-CU-3001 FOR MANHOLE REHABILITATION.
5. SEE SHEET III-GI-0002 FOR LEGEND AND ABBREVIATIONS.
6. SEE SHEET III-GI-0003 FOR GENERAL NOTES.
PARCEL 102-01-076A EXHIBIT 1
AutoCAD SHX Text
WALL
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DETAIL NO.
STANDARD DETAIL
ENGLISH
REVISED
DETAIL NO.
01-01-2015
MANHOLE FRAME
AND COVER ADJUSTMENT
ADJUSTING RING DETAIL
SPACER TYPE
BRICK
4"X2" STEEL SPACER
GROUT
REQUIRED THICKNESS
GREATER THAN 2"
" TO 2"
LESS THAN
NOTES:
1. CONTRACTORS SHALL ADJUST ALL MANHOLE RINGS AND
COVERS, INCLUDING MANHOLES OUTSIDE OF THE
PAVEMENT.
2. COAT INTERIOR SURFACES OF GRADE RINGS WITH
REHABILITATION COATING SPECIFIED FOR THAT MANHOLE.
3. GROUT SHALL BE USED BETWEEN FRAME AND ADJUSTING
RING TO ACHIEVE WATER TIGHTNESS.
4. MAXIMUM HEIGHT OF OPENING BETWEEN THE BOTTOM OF
THE MANHOLE CONCRETE TOP AND TOP GRADE RING SHALL
BE 24". FOR MANHOLES REQUIRING ADJUSTMENTS GREATER
THAN 24" THE ADJUSTMENT SHALL INCLUDE NEW BARREL
SECTIONS, PER DETAIL ON SHEET III-CU-3003.
2-1/8"
1/4"
1-5/8"
1/4"
1-3/4"
2-1/4"
1/4"
1/4"
2-1/4"
1"
6"
12" MIN.
BOTH SIDES
OUT OF
PAVEMENT-FINISH
GRADE
(2) NO.2 HOOPS FOR 4"
RING TIED WITH NO.4
A.S. & W. GAUGE WIRE.
6" & 8" RING REQUIRE
(4) NO.2 HOOPS.
MEDIUM BROOM
FINISH WITH
RADIALLY SCORED
MARKS (4 MIN.)
NEW MANHOLE
LID AND FRAME
EXISTING OR RECENTLY
INSTALLED PAVEMENT
#4 REINFORCING STEEL HOOP EQUALLY
CENTERED HORIZONTALLY AND VERTICALLY
(IF REQUIRED BY AGENCY)
4000 PSI CONCRETE
COMPACTED SUBGRADE TO 95%
MAXIMUM DRY DENSITY
(BENEATH ROADWAY) OR
85% MAXIMUM DRY DENSITY
(OPEN GRASS SURFACES)
FLAT REINFORCED CONCRETE TOP
M
A X
S
T
E S
M
I N
M
I N
GROUT INTERIOR
SURFACE OF
ADJUSTMENT
RINGS
CONTINUOUS
V A
R I E
S
PROTECT STEPS IN-PLACE
REHABILITATE ALL INTERIOR CONCRETE SURFACES
(INCLUDING INTERIOR OF CONCRETE MANHOLE TOP)
WITH EITHER PROTECTIVE LINING SYSTEM OR
CARBON FIBER COMPOSITE SYSTEM
NOTES:
1. SEE SHEET III-GI-0004 FOR TABLE IDENTIFYING REQUIRED MANHOLE REHABILITATION SYSTEM (CARBON PROTECTIVE LINER
SYSTEM OR CARBON FIBER COMPOSITE SYSTEM).
2. MANHOLE FRAME AND ADJUSTMENT TO GRADE SHALL BE COMPLETED PRIOR TO ANY MANHOLE REHABILITATION.
3. PRIOR TO PLACEMENT OF THE CIPP, HYDROPHILIC END SEALS SHALL BE PLACED AT THE DOWNSTREAM AND UPSTREAM
ENDS OF THE EXISTING PIPE TO MAKE A TIGHT FITTING SEAL WITH THE CIPP AT EACH MANHOLE. SEE DRAWING III-CU-3002, DETAIL 5.
4. CURED-IN-PLACE PIPE SHALL BE THEN INSTALLED INTO EACH SEWER REACH.
5. TO PROVIDE ACCESS TO THE MANHOLE, TOP HALF OF THE LINER SHALL BE NEATLY CUT OFF A MAXIMUM OF 4 INCHES
AND A MINIMUM OF 2 INCHES FROM THE MANHOLE WALLS TO ALLOW THE LINER TO LOCK IN AT THE MANHOLE OPENING.
6. SEE SPECIFICATION 46.04.00 CURED-IN-PLACE PIPE (CIPP) FOR FOR OTHER CIPP INSTALLATION REQUIREMENTS.
7. FOR MANHOLES, SEE EITHER SPECIFICATION 46.05.00 PROTECTIVE LINER SYSTEM OR SPECIFICATION 46.06.00 CARBON
FIBER COMPOSITE SYSTEM, AS IDENTIFIED ON THE REQUIRED MANHOLE REHABILITATION TABLE SHOWN ON III-GI-0004.
8. SEE DETAIL 5, SHEET III-CU-3002 FOR CIPP LINER/MANHOLE REHABILITATION INTERFACE.
9. MANHOLE REHABILITATION USING EITHER A PROTECTIVE LINER SYSTEM (SPECIFICATION 46.05.00) OR A CARBON FIBER
COMPOSITE SHALL (SPECIFICATION 46.06.00) BE COMPLETED AFTER THE INSTALLATION OF THE CIPP.
10. SEE SHEET III-GI-0002 FOR LEGEND AND ABBREVIATIONS.
11. SEE SHEET III-GI-0003 FOR GENERAL NOTES.
WHEN INSTALLING CIPP LINER THROUGH
MANHOLE REMOVE TOP PORTION OF LINER
WITHIN THE MANHOLE TO RE-ESTABLISH
ACCESS. WHEN TERMINATING CIPP LINER AT
MANHOLE, INSTALL AND SEAL IN ACCORDANCE
WITH DETAIL 5, ON SHEET III-CU-3002.
D r a
D e s i g n e d b y
R e v i e w e d b y
D a t e
S u b m i t t e d b y
D e s c r i p t i o n
D a t e
A c t i o n
S o l i c i t a t i o n
N o
C o n t r a c t
N o
R e v
Sheet
Reference
Number:
F i l e
N a m e
P l o t
D a t e
P l o t
S c a l e
S y m b o l
L A
G E
P r o j e c t s I N
F R i b w c I B g i n e e r i n g
S e r v i c e s T a s k
O r d e r
I B
M
T
N o g a l e s
I O
I
D r a w i n g s P h a s i i g n P l a n
S h e e t s
C
F S
H E
E T
S I B
M
T
I I I C
U d o t t e d
W e d n e s d a y
M a y
P
M
T r a c k i n g
N o
I B
M T
I I I C
U d w g
P R
O J E
U R
S
C
O R
P O
R A
T I O
N
E
A S
T
W
E T
M O
A
D
S U
I T
E
C
S O
N
A
Z
U S
I N
T E
R N
A T
I O
N A
L
B
O U
N D
A R
Y
W A
T E
R
C
O M
M I S
S I O
N
N O
G A
L E
S
A
Z
S L
S
S L
S
T S
S
C H
A R
L E
S
P
E D
R I
P
E
T
E D
R E
H A
B I L
I T
A T
I O
N
I M
P R
O V
E M
E N
T S
T R
U N
K L
I N
E
A
T E
R N
A T
I O
N A
L
O
U T
F A
L L
I N
T E
R C
E P
T O
R
S
A N
U
Z
C
O U
N T
Y
A
Z
P H
A S
E
I I I
I B
M T
III-CU-3001
M A
N H
O L
E
R
E H
A B
I L
I T
A T
I O
N
D
E T
A I L
S
S H
E E
MANHOLE SURFACES TO RECEIVE REHABILITATION
DETAIL
NOT TO SCALE
DETAIL
NOT TO SCALE
STD. MANHOLE OUTSIDE FLOODWAY
MANHOLE 33 TO 93
STD. MANHOLE OUTSIDE FLOODWAY
MANHOLE 94 TO 99
PARCEL 102-01-076A EXHIBIT 1
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text a
D e s i g n e d b y
R e v i e w e d b y
D a t e
S u b m i t t e d b y
D e s c r i p t i o n
D a t e
A c t i o n
S o l i c i t a t i o n
N o
C o n t r a c t
N o
R e v
Sheet
Reference
Number:
F i l e
N a m e
P l o t
D a t e
P l o t
S c a l e
S y m b o l
L A
G E
P r o j e c t s I N
F R i b w c I B g i n e e r i n g
S e r v i c e s T a s k
O r d e r
I B
M
T
N o g a l e s
I O
I
D r a w i n g s P h a s i i g n P l a n
S h e e t s
C
F S
H E
E T
S I B
M
T
I I I C
U d o t t e d
W e d n e s d a y
M a y
P
M
T r a c k i n g
N o
I B
M T
I I I C
U d w g
P R
O J E
U R
S
C
O R
P O
R A
T I O
N
E
A S
T
W
E T
M O
A
D
S U
I T
E
C
S O
N
A
Z
U S
I N
T E
R N
A T
I O
N A
L
B
O U
N D
A R
Y
W A
T E
R
C
O M
M I S
S I O
N
N O
G A
L E
S
A
Z
S L
S
S L
S
T S
S
C H
A R
L E
S
P
E D
R I
P
E
T
E D
R E
H A
B I L
I T
A T
I O
N
I M
P R
O V
E M
E N
T S
T R
U N
K L
I N
E
A
T E
R N
A T
I O
N A
L
O
U T
F A
L L
I N
T E
R C
E P
T O
R
S
A N
U
Z
C
O U
N T
Y
A
Z
P H
A S
E
I I I
I B
M T
III-CU-3002
M A
N H
O L
E
R
E H
A B
I L
I T
A T
I O
N
D
E T
A I L
S
S H
E E
24" CAST IRON WATERTIGHT
MANHOLE FRAME AND COVER
424-1 ENGLISH
STANDARD DETAIL
424-1
XX
XX
M
AD
E
IN
U
SA
XXX
CLASS 35B
XX
X
AASHTO M
XX
XX
USA
CLASS 35B
AASHTO M306
XXX
XXX
NC
AG
E
IY DENTIFICATION
U T I L I T Y T Y PE
33 3/4"
INITIAL BACKFILL
FOUNDATION
SAWCUT
SEE NOTE 2.
SELECT
BACKFILL
MATERIAL
SPRINGLINE
BEDDING
HAUNCHING
4" TOPSOIL
F I N
A L
B
A C
K F
I L L
F I N
A L
B
A C
K F
I L L
E M
B A
N K
M E
N T
P I P
E
Z
O N
E
O.D. CLEARANCE
PIPE O.D. +24"
PAVED AREAS UNPAVED AREAS
TYPICAL TRENCH SECTION
NOTE:
1. SEE SPECIFICATION SECTION 31.23.20 FOR PIPE, BEDDING,
BACKFILL, AND SURFACE RESTORATION REQUIREMENTS.
NATIVE BACKFILL
DETAIL
NOT TO SCALE
DETAIL 4
NOT TO SCALE
DETAIL
NOT TO SCALE
2. JOINT LOCATION OR JOINT CONFIGURATION SHALL BE TO
ELIMINATE FULL DEPTH SAW CUT JOINTS FROM BEING
LOCATED WITHIN A WHEEL PATH.
12"
ASPHALT CONCRETE
(MATCH THICKNESS
OF EXISTING PAVEMENT)
NOTES:
1. SEE SHEET III-GI-0002 FOR LEGEND AND ABBREVIATIONS.
2. SEE SHEET III-GI-0003 FOR GENERAL NOTES.
EXISTING
RCP PIPE
MANHOLE REHABILITATION
EITHER PROTECTIVE LINER SYSTEM
OR CARBON FIBER COMPOSITE
NEW END SEAL
SLEEVE (TYP)
MANHOLE REHABILITATION
EITHER PROTECTIVE LINER SYSTEM
OR CARBON FIBER COMPOSITE
LINER/MANHOLE REHABILITATION INTERFACE
WHEN TERMINATING CIPP LINER AT MANHOLE
EXISTING
RCP PIPE
CIPP LINER (TYP)
NOTE 1
AGGREGATE
BASE COURSE
EXISTING
MANHOLE
NOTE:
1. CONTRACTOR SHALL LEAVE A MINIMUM OF 2 INCHES
OF CIPP FROM THE EDGE OF THE CHANNEL ON BOTH
SIDES TO ALLOW FOR POSSIBLE SHRINKAGE OF LINER.
2. DO NOT APPLY MANHOLE REHABILITATION SYSTEM
TO LATERAL. THOROUGHLY CLEAN INTERIOR AND
EXTERIOR SURFACES OF ALL LATERALS OF ANY
SYSTEM COMPONENT.
EXISTING LATERAL
(SEE NOTE 2)
PARCEL 102-01-076A EXHIBIT 1
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DETAIL NO.
AutoCAD SHX Text
REVISED
AutoCAD SHX Text
DETAIL NO.
AutoCAD SHX Text 01-01-2012
AutoCAD SHX Text
%%UFRAME TOP VIEW
AutoCAD SHX Text
%%UCOVER TOP VIEW
AutoCAD SHX Text
FRAME WT. (CL. 35) - 180 LBS
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text
%%UCOVER BOTTOM VIEW
AutoCAD SHX Text
HEAT DATE
AutoCAD SHX Text
MANUFACTURES NAME
AutoCAD SHX Text 1 1/16"
AutoCAD SHX Text 26 1/8"
AutoCAD SHX Text 1 3/16"
AutoCAD SHX Text 22 3/4"
AutoCAD SHX Text 2 1/2"
AutoCAD SHX Text
COVER WT. (CL. 35) - 188 LBS
AutoCAD SHX Text
MANUFACTURES NAME
AutoCAD SHX Text
ORIGIN
AutoCAD SHX Text
AASHTO M306 CLASS 35B
AutoCAD SHX Text
MODEL NUMBER
AutoCAD SHX Text
HEAT DATE
AutoCAD SHX Text
MODEL NUMBER MANUFACTURES NAME
AutoCAD SHX Text
RECYCLE SIGN
AutoCAD SHX Text
OPTIONAL LOGO OR AREA WITH RAISED CIRCLE FLUSH 1/8'
AutoCAD SHX Text
RAISED RINGS 1/8"
AutoCAD SHX Text 6"
AutoCAD SHX Text 26 3/8"
AutoCAD SHX Text 27 13/16"
AutoCAD SHX Text 1 3/16"
AutoCAD SHX Text 4 1/16"
AutoCAD SHX Text 24"
AutoCAD SHX Text R3/4"
AutoCAD SHX Text
BATTER 3/16"
AutoCAD SHX Text NOTE: : LETTERING ON MANHOLE COVER TO CONTAIN NAME OF AGENCY AND UTILITY FOR WHICH MANHOLE IS NEEDED, (I.E. "PHOENIX SANITARY SEWER"), OR AS DIRECTED. THE TOTAL WIDTH OF INDIVIDUAL LETTERS TO BE SUCH THAT LETTERS AND WORDS ARE EQUALLY SPACED AND BALANCED TO FORM A COMPLETE CIRCLE WITH SPACERS BEFORE AND AFTER THE WORD IDENTIFYING THE AGENCY INVOLVED. LETTERS TO BE 2" IN HEIGHT AND RAISED FLUSH W/ TOP OF COVER. TYPE OF LETTERS TO BE SUBMITTED FOR APPROVAL. WEIGHT OF CASTINGS SHALL BE NO MORE THAN 2% MORE OR LESS THAN THE APPROXIMATE WEIGHT SPECIFIED. CASTINGS SHALL CONFORM TO ASTM A-48, CLASS 35 AND AASHTO M306. THE BEARING SURFACES OF THE FRAMES AND COVERS SHALL BE MACHINED AND THE COVERS SHALL SEAT FIRMLY WITHOUT ROCKING. ALL DIMENSIONS SHALL HAVE A 1/16" TOLERANCE.
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text
SECTION B
AutoCAD SHX Text
SECTION C
AutoCAD SHX Text
SECTION A
AutoCAD SHX Text
SECTION D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text 3/16"
AutoCAD SHX Text
BATTER
AutoCAD SHX Text R1/4"
AutoCAD SHX Text R3/8"
AutoCAD SHX Text 7"
AutoCAD SHX Text
CONCEALED PICK DETAIL
AutoCAD SHX Text 1 3/8"
AutoCAD SHX Text 5/8"
AutoCAD SHX Text
WITH GASKET
AutoCAD SHX Text 1/8"
AutoCAD SHX Text 3/16"
AutoCAD SHX Text
BATTER
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
TAPER 1/2" TO 3/4"
AutoCAD SHX Text
MACHINED
AutoCAD SHX Text
MACHINED
AutoCAD SHX Text 2"
AutoCAD SHX Text 1/4"
AutoCAD SHX Text 9/16"
AutoCAD SHX Text
MIN. 8 GUSSETS W/ MIN. TAPER 5/8" TO 3/4"
AutoCAD SHX Text
NAME OF AGENCY OR UTILITY REQUIRED 1/8" RAISED
7/8" DIA DRILL AS NECESSARY FOR MACHINING
a
D e s i g n e d b y
R e v i e w e d b y
D a t e
S u b m i t t e d b y
D e s c r i p t i o n
D a t e
A c t i o n
S o l i c i t a t i o n
N o
C o n t r a c t
N o
R e v
Sheet
Reference
Number:
F i l e
N a m e
P l o t
D a t e
P l o t
S c a l e
S y m b o l
L A
G E
P r o j e c t s I N
F R i b w c I B g i n e e r i n g
S e r v i c e s T a s k
O r d e r
I B
M
T
N o g a l e s
I O
I
D r a w i n g s P h a s i i g n P l a n
S h e e t s
C
F S
H E
E T
S I B
M
T
I I I C
U d o t t e d
W e d n e s d a y
M a y
P
M
T r a c k i n g
N o
I B
M T
I I I C
U d w g
P R
O J E
U R
S
C
O R
P O
R A
T I O
N
E
A S
T
W
E T
M O
A
D
S U
I T
E
C
S O
N
A
Z
U S
I N
T E
R N
A T
I O
N A
L
B
O U
N D
A R
Y
W A
T E
R
C
O M
M I S
S I O
N
N O
G A
L E
S
A
Z
S L
S
S L
S
T S
S
C H
A R
L E
S
P
E D
R I
P
E
T
E D
R E
H A
B I L
I T
A T
I O
N
I M
P R
O V
E M
E N
T S
T R
U N
K L
I N
E
A
T E
R N
A T
I O
N A
L
O
U T
F A
L L
I N
T E
R C
E P
T O
R
S
A N
U
Z
C
O U
N T
Y
A
Z
P H
A S
E
I I I
I B
M T
III-CU-3003
N E
W
C
O N
C R
E T
E
S
A N
I T
A R
Y
S
E W
N
H O
L E
NOTES:
1. SEE SHEET III-GI-0002 FOR LEGEND AND ABBREVIATIONS.
2. SEE SHEET III-GI-0003 FOR GENERAL NOTES.
420-1
CONCRETE SANITARY SEWER MANHOLE
DETAIL NO.
STANDARD DETAIL
ENGLISH
01-01-2015
REVISED
420-1
DETAIL NO.
420-2
DETAIL NO.
STANDARD DETAIL
ENGLISH
REVISED
420-2
DETAIL NO.
PRECAST CONCRETE MANHOLE BASE
01-01-2015
420-3
DETAIL NO.
STANDARD DETAIL
ENGLISH
01-01-2015
REVISED
420-3
DETAIL NO.
CONCRETE MANHOLE BASE
DETAIL
NOT TO SCALE
DETAIL
NOT TO SCALE
DETAIL
NOT TO SCALE
PARCEL 102-01-076A EXHIBIT 1
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
%%UTYPE 'A' TOP
AutoCAD SHX Text
4" TYP.
AutoCAD SHX Text
(PRECAST ECCENTRIC CONICAL TOP MANHOLE)
AutoCAD SHX Text
USE BUTYL RUBBER MASTIC JOINT SEALANT ON ALL JOINTS; EXCEPT TOP ADJUSTMENT RINGS
AutoCAD SHX Text
8" IF MANHOLE IS 13' OR LESS 12" IF MANHOLE IS OVER 13'
AutoCAD SHX Text
OVERALL ADJUSTMENT RING HEIGHT SHALL BE 12" MIN TO 18" MAX (TYP)
AutoCAD SHX Text NOTES: 1. PRECAST STEEL REINFORCED MANHOLE SECTIONS PRECAST STEEL REINFORCED MANHOLE SECTIONS SHALL BE MANUFACTURED IN ACCORDANCE WITH ASTM C 478 EXCEPT AS MODIFIED HEREIN. 2. CAST-IN-PLACE MANHOLE BASE TO BE CAST-IN-PLACE MANHOLE BASE TO BE CONSTRUCTED IN ONE PLACEMENT. 3. CAST-IN-PLACE MANHOLE BASE SHELF AND CAST-IN-PLACE MANHOLE BASE SHELF AND CHANNEL TO RECEIVE SMOOTH TROWEL FINISH. 4. MANHOLE COATINGS PER AGENCY. MANHOLE COATINGS PER AGENCY. 5. SEE DETAIL 1, SHEET III-CU-3001 FOR FINAL SEE DETAIL 1, SHEET III-CU-3001 FOR FINAL ADJUSTMENT TO GRADE. 6. ANY MANHOLE OVER 20' SHALL REQUIRE ENGINEER ANY MANHOLE OVER 20' SHALL REQUIRE ENGINEER (STRUCTURAL) CALCS. 7. THE MANHOLE ACCESS POINT SHALL BE ORIENTED THE MANHOLE ACCESS POINT SHALL BE ORIENTED IN SUCH A WAY THAT THE OPENING IS DIRECTLY ABOVE THE LOWEST INVERT, OR AS OTHERWISE DIRECTED BY THE PLANS OR ENG. 8. FOR PRECAST BASE SEE DETAIL 7, THIS SHEET. FOR PRECAST BASE SEE DETAIL 7, THIS SHEET. 9. FLAT TOPS SHALL ONLY BE USED WITH APPROVAL FLAT TOPS SHALL ONLY BE USED WITH APPROVAL FROM THE ENGINEER.
AutoCAD SHX Text
PRECAST RISER SECTIONS AS REQUIRED
AutoCAD SHX Text
24" OR 30" FRAME & COVER PER DETAIL 3, SHEET III-CU-3002 (TYP)
AutoCAD SHX Text
%%U(PRECAST FLAT TOP M.H.)
AutoCAD SHX Text
8"MIN.
AutoCAD SHX Text
8" TYP.
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
3" MIN. 5" MAX.
AutoCAD SHX Text
KEYWAY PRESSED INTO BASE TO MATCH PRECAST RISER
AutoCAD SHX Text
DIAMETER PER PLAN
AutoCAD SHX Text
FLAT REINFORCED CONC. TOP
AutoCAD SHX Text
FINISH GRADE (TYP)
AutoCAD SHX Text
24" TO 26-3/4" ON 48" MANHOLE 30" ON 60" MANHOLE (TYP)
AutoCAD SHX Text
CEMENT MORTAR
AutoCAD SHX Text
3,000 PSI CONCRETE BASE
AutoCAD SHX Text
30" MIN. 36" MAX.
AutoCAD SHX Text
24" MAX ADJUSTING RINGS PER DETAIL 1, SHEET III-CU-3001 (TYP)
AutoCAD SHX Text
CONCRETE SHELF SHALL BE PER SECTION A-A DETAIL 8, THIS SHEET
AutoCAD SHX Text
24" MAX.
AutoCAD SHX Text
30"DIA MIN.
AutoCAD SHX Text NOTES: PRECAST, MANUFACTURER SHALL BE AN NATIONAL PRECAST CONCRETE ASSOCIATION (NPCA) CERTIFIED PLANT. ENTIRE PRECAST BASE SHALL BE ENTIRE PRECAST BASE SHALL BE MANUFACTURED AT THE PLANT PER ASTM C478. 3000 PSI CONCRETE SHALL BE USED FOR PRECAST MANHOLE BASES. SPRING LINE OF CAST-IN-PLACE BELL SHALL STOP AT INSIDE FACE OF MANHOLE. JOINTS FOR BARREL SECTION SHALL BE TONGUE AND GROOVE TYPE. ALL LIFTING HOLES SHALL BE SEALED WITH GROUT. ALL PRECAST MANHOLE BASES SHALL BE PLACED ON 8" MINIMUM OF ABC COMPACTED TO 100% MAXIMUM DENSITY. ALL MODIFICATIONS SHALL BE APPROVED BY THE ENGINEER. MINIMUM WALL THICKNESS SHALL BE PER ASTM C478 (MIN 5"). REINFORCEMENT SHALL BE DESIGNED BY AN ARIZONA REGISTERED PROFESSIONAL ENGINEER. CHANNEL TRANSITION SHALL BE CONSTANT FROM INLET TO OUTLET OF MANHOLE TO FACILITATE SMOOTH TRANSITIONS AND ACCOMMODATE CORRESPONDING MANDREL. THERE SHALL BE NO HARD CONNECTIONS (GROUTED) INTO THE MANHOLE BASE UNLESS APPROVED BY THE ENGINEER. ALL SEWER SERVICE CONNECTIONS SHALL HAVE THE SAME CONNECTION TYPES IN THE PRECAST MANHOLE BASE. ALL CORE HOLES INTO THIS STRUCTURAL PRECAST BASE SHALL BE COATED WITH AN APPROVED COATING MATERIAL. THE MANHOLE BOTTOM SHALL EXTEND OUTSIDE THE MANHOLE WALL A MINIMUM 6" WIDE ON 48" BASES, 7" WIDE ON 60" BASES, AND 8" WIDE ON 72" BASES. EXTENDED BOTTOM SHALL BE A MINIMUM OF 5" THICK. ALL PIPE CONNECTIONS SHALL BE IN COMPLIANCE WITH ASTM C923.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PROVIDE 1' LENGTH OF FACTORY PRODUCED CLAY PIPE
AutoCAD SHX Text
STANDARD LENGTH PIPE
AutoCAD SHX Text
PROVIDE 2' LENGTH OF FACTORY PRODUCED EXTRA STRENGTH VITRIFIED CLAY PIPE
AutoCAD SHX Text
DIAMETER PER PLAN
AutoCAD SHX Text
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
AutoCAD SHX Text
OUTLET PIPE PER APPROVED PLANS
AutoCAD SHX Text
UNDISTURBED NATIVE SOIL
AutoCAD SHX Text
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
CLAY PIPE
AutoCAD SHX Text
OTHER PIPE TYPES
AutoCAD SHX Text
8" MIN.
AutoCAD SHX Text
TRENCH FACE (TYP)
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
AutoCAD SHX Text
IF NO SIDE SEWERS, FORM ONE CONTINUOUS CHANNEL
AutoCAD SHX Text CHANNEL TRANSITION SHALL BE CONSISTENT FROM INLET TO OUTLET OF MANHOLE TO FACILITATE SMOOTH TRANSITIONS AND ACCOMMODATE CORRESPONDING MANDREL.
AutoCAD SHX Text
%%USECTION A-A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
%%UTYPICAL CHANNEL
AutoCAD SHX Text
TOP OF SHELF TO TOP OF PIPE (MIN 2% SLOPE) NOT TO EXCEED 3"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
90° MIN ANGLE
AutoCAD SHX Text
2"± RADIUS
90° MIN ANGLE
AutoCAD SHX Text
CHANNEL, FORMED WITH PRECAST AND CAST IN PLACE BASE, (TYP).
AutoCAD SHX Text
OUTLET PIPE PER APPROVED PLANS
AutoCAD SHX Text
OUTLET PIPE PER APPROVED PLANS
AutoCAD SHX Text
SEE DETAIL 7, THIS SHEET FOR NOTES
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
PROVIDE A ±12 INCHTANGENT AT ALL PIPE CONNECTIONS (TYP)
2"± RADIUS
9/24/2020 Property Inquiry parcelsearch.co.santa-cruz.az.us/RWDataMartPropertyInquiry/ParcelDetail.aspx?a=c2a02bad-3ac1-4408-89dc-f3954411cdeb 1/2
Property Records Inquiry
Revise Search Print This Page
General Information 2021
Property Address Owner Name & Address
1982 SMOKEY LANE
NOGALES, 85621
Primary Owner
SAINZ FAMILY REGISTERED L L P
ARIMEX
356 VIA BELLA DONNA
RIO RICO, AZ 85648
100.00%
Legal Description
Subdivision: Lot: Block:
Section: 5, Township: T24, Range: R14
Extended Legal: A PORTION OF LAND IN THE N2 SE4 OF SECTION 5 T24S R14E
Property Information
Parcel Number: 10201076A Account Number: R000002667
Tax District: 0150 Current Mill Levy: 0
Square Feet: 35,283.60 Total Acres: 0.81
Primary Use Description: 3710-WAREHOUSING
Sales Information
Reception # Sale Price Deed Type SaleDate Grantor Grantee
19970000735 $325,000 WARRANTY DEED 01/31/1997 JESUS BARRON-TAPIA M. BARRON JUAN D. SAINZ AND GUADALUPE
Value Information Approach: Cost
Abstract Code/Description Value Type Appraised Value Assessed Value Taxable Value
0112I Commercial / Real and Improvements Improvement $300,799 $54,144 $54,144
0112L Commercial / Real and Improvements Land $44,105 $7,939 $7,939
Totals: $344,904 $62,083 $62,083
Limited Property Value (LPV)
Abstract Code/Description Value Type LPV Actual LPV Assessed LPV Taxable Value
0112I Commercial / Real and Improvements Improvement $300,799 $54,144 $54,144
0112L Commercial / Real and Improvements Land $44,105 $7,939 $7,939
Totals: $344,904 $62,083 $62,083
Account Flags
Flag Type Flag Description Unit Count
Property Attributes & Descriptions
Attribute Attribute Description
The Parcel has the following Exemptions:
A2 Physically Unchanged Improvement
Building ID 1.00 Occupancy Description Distribution Warehouse Rooms 0
Built As Distribution Warehouse Bedrooms 0
Exterior Baths 0
HVAC Package Unit Year Built 1980
[BuildingImage]
Detail Type Detail Description Units
PARCEL 102-01-076A EXHIBIT 2
http://parcelsearch.co.santa-cruz.az.us/RWDataMartPropertyInquiry/Inquiry.aspx http://parcelsearch.co.santa-cruz.az.us/RWDataMartPropertyInquiry/Inquiry.aspx javascript:window.print()
9/24/2020 Property Inquiry parcelsearch.co.santa-cruz.az.us/RWDataMartPropertyInquiry/ParcelDetail.aspx?a=c2a02bad-3ac1-4408-89dc-f3954411cdeb 2/2
Add On Ext. Steel Stairway - NAA 12.0000
Mezzanine Office 318.0000
Add On Barbed Wire - WCB 668.0000
Add On Concrete Block Wall - WAC 1182.0000
Add On Chain Link Fence - WCL 1320.0000
Add On CANOPY,MANSARD,METAL FR W/ELEC - QZE 1308.0000
Add On Dock Levelers, Mech - DBW 1.0000
Add On Chain Link Fence - WCL 4256.0000
Add On Gate, Chain Link - WCG 210.0000
Mezzanine Storage 216.0000
Add On Paving, Concrete unreinforced - PCU 14529.0000
<< Return to Results
PARCEL 102-01-076A EXHIBIT 2
!"#$%"&'()�*'+",-$'�."/&#$'(0$/$-(1"'�2$45""6�7�89:$;$94/<�."/&#$'(."/&#$'(."/&#$'(�29#$;&3=1>1?1"'@49/(0$?&A(?%"&'()�%"'(9/(?.9(9�B>91A931A1();$4>1/$?,>$4>1$C;&3?/41-(1"'�8A9'?!1?("41/9A�.9(9B//"&'(�;$(&-(/4D$3@""A?D<9(�*?�D$3@""A?B--A$�E9/�F?$4?."C'A"9=!$A-*'(4"=&/(1"',-$'�."/&#$'(;$94/<1':G&1=$A1'$?;$94/<�%41($41929#$�;$94/<$?D1A=/94=�;$94/<$?;$94/<�0$?&A(?*#9:$?*#9:$�*'+".91A)�H1#1(I1$C1':�84"3A$#?H9?(�8$4+$/($=�."/&#$'(;<"4(/&(�J$)?B==1(1"'9A�!$A-B3"&(�;$A$/(�;(9($�B0*K,2B ���G"�;$A$/(�%"&'()�;B2@B�%0FK ���G"�H1?(�"+�%"&'(1$?
�."/&#$'(�*=$'(1+1$4 LMML7MNNOM � 84$>�."/ ��� 2$P(�."/5""6789:$ .,%JQ@7RST7ORM0$/"4=1':�.9($7@1#$ MO7SL7LMML�MOUMMUMM�8E."/&#$'(�@)-$ .QQ.�,V�@0F;@WV*2X;@XY�B;;2X89:$�%"&'( SOI1$C�*#9:$ *#9:$�'"(�9>91A93A$�.$?/41-(1"' �."/&#$'(�29#$? 5B2J�,2Q;B*2K�VBE*HZ�8B0@2Q0;!*8�0$A9($=�."/&#$'(?�7�B++$/($=5) 0$/$-(1"'[ ."/&#$'(�@)-$ 0$A9(1"'?<1-LMM\7MT\\M .QQ.�,V0QHQB;QW0Q%,2IQZB2%Q�H$:9A H"( 5A"/6;&3=1>1?1"'�� ;$/(1"'@"C'?<1-09':$M] LO; SOQ�� 894/$A�*.SML7MS7MT\B�� ;(4$$( %1()SR̂L�2�;E,JQZ�HB2Q2,GBHQ;�0$/"4=1':�V$$? V$$�29#$ B#"&'(0$/"4=1': _MXMM0$9A�84"-$4()�@49'?+$4 _MXMM%"&'()�;&4/< _MXMM8"?(9:$ _MXMM;(9($�;&4/< _MXMMB??$??"4�;&4/< _MXMM`̀̀ `̀̀ `̀̀ `̀@"(9A�V$$ _MXMM� abcdefgh�ibghfgh�jdfkhlbgkm�-A$9?$�/"'(9/(�(<$�9--4"-419($�%"&'()�0$/"4=$4n?�,++1/$X��ofp�qlhf�jdfkhlbgkm�-A$9?$�?$'=�9')�r&$?(1"'?�"4�/"##$'(?�4$:94=1':�(<1?�?1($�("�;&--"4(X��@<1?�C$3�?1($�9'=�hsfibdghtufcbvwfv@E�94$�(<$�-4"-$4()�"+�;9&An?�%4$$6�Q':1'$$41':x�*'/Xx�%"A"49="�;-41':?�%,X
HBDZQ0;�@*@HQ�,V�B0*K,2BW%J[LRRRTT�*2;@0FEQ2@�.B@QU�MNLTML�;QO�;Q%X]�@D8LO;�0SOQ;@B@QEQ2@�.B@QU�MNLTML�;QO�;Q%X]�@D8LO;�����0SOQ*2;@0FEQ2@�.B@QU�MNLTML�_SSTxMMMXMM������������������������������;QO�;Q%X]�@D8LO;�0SOQ_SSTxMMMX7;QO�;Q%X]�@D8LO;�0SOQ_SSTxMMMX7;QO�;Q%X]�@D8LO;�0SOQ
�yz{i|}~y�u{�|��{���|� ��;&3?/413$4�H":�*'������������������������������������������ PARCEL 102-01-076A EXHIBIT 2 ra w n by
D es ig ne d by
R ev ie w ed b y:
D at e:
S ub m itt ed b y:
D es cr ip tio n
D at e A ct io n
S ol ic ita tio n
N o.
C on tr ac t N o.
R ev
Sheet Reference Number:
F ile
N am e:
P lo t D at e:
P lo t S ca le
S ym bo l
L:
\A
G E
\P ro je ct s\
IN
F R
\ib w c\
IB
W C
E ng in ee rin g
S er vi ce s\ T as k
O rd er
IB
M
T
N og al es
IO
I\0
8- D ra w in gs
\P ha se
D es iig n\
P la n S he et s\
-G C
-S H
E E
T S
\II
I-
G C
-1
1-
.d lo tte d:
W ed ne sd ay
, M ay
9, :0 0:
P
M
T ra ck in g N o.
/2 6/
III
-G
C -1
1-
.d w g
P R
O
JE
C T
N O
. 4
U R
S C
O R
P O
R A
T
IO
N
E
A S
T W
E T
M O
R E
R O
A D
S
U
IT
E
T
U C
S O
N , A
Z
(5
7-
U .S
. I N
T E
R N
A T
IO
N
A L
B O
U N
D A
R Y
W
A T
E R
C O
M M
IS
S
IO
N
N O
G A
LE
S
, A Z
IB
M
D
S
LS
S
LS
T S
S
C H
A R
LE
S
P E
D R
I, P
.E
/2
6/
A S
N O
T E
D
R E
H A
B
IL
IT
A
T
IO
N
IM
P R
O V
E M
E N
T S
T R
U N
K
LI
N E
A N
D
IN
T E
R N
A T
IO
N
A L
O U
T F
A
LL
IN
T
E R
C E
P T
O R
, S A
N T
A C
R U
Z C
O U
N T
Y , A
Z P
H A
S E
II
I
MH #42
MH #43
MH #44
MH #45
MH #46
MH #47
MH #41
MH #40
PHASE III PROJECT
BEGIN CIPP PIPING
CL MH # 37
STA 112+39.39
N=131838.51 E=1008203.91
PHASE III PROJECT
BEGIN BYPASS PIPING
CL MH # 36A
STA 112+00.00
N=131800.36 E=1008194.36
MH #39
MH #44-A1 MH #44-A
MH #44-B
MH #44-C
III-GC-1001
G E
N E
R A
L A
R R
A N
G E
M E
N T
S H
E E
T
O F
N GRAND AVE
N GRAND AVE
N GRAND AVE
N
D E
T E
N T
IO
N
R D
N HOHOKAM DR
N SMOKEY LN
E C
A
LL
E S
O N
O R
A
E B
A F
F E
R T
D R
E T
E R
M
IN
A L
P R
O D
U C
E D
R
E B
A
FF
E R
T D
R
E M
A Y
R A
D R
126 124
N SMOKEY LN
M A
T C
H L
IN
E
S T
A
MATCH LINE STA 161+50
M A
T C
H L
IN
E
S T
A
UNION PACIFIC NOGALES BRANCH RR
UNION PACIFIC NOGALES BRANCH RR
RR ROW
RR ROW
RR ROW
RR ROW
RR ROW
RR ROW
RR ROW
N GRAND AVE
HORIZONTAL
SSx
SSx
MH #35
MH #34
SSx
MH #36
N HOHOKAM DR
POTENTIAL BYPASS PUMP
STATION LOCATION
MH #37A
MH #38
LEGEND
PROPOSED CURED IN PLACE PIPE
PROPOSED BYPASS PIPE LINE
PROPOSED TRUNKLINE AND IOI
PIPE LINE EASEMENT
EXISTING STORM SEWER MAIN
EXISTING RAILROAD RIGHT OF WAY
EXISTING PARCEL LINE
EXISTING STORM MANHOLE
PL
BYP
PLE
SSx
RR ROW
NOTES:
1. PARCEL DATA PROVIDED BY GEOGRAPHIC MAPPING APPLICATION
AND SANTA CRUZ COUNTY GIS. PARCEL BOUNDARIES ARE
APPROXIMATE. HORIZONTAL COORDINATES: NAD83.
2. THE AERIAL IMAGE MAY NOT REFLECT EXISTING CONDITIONS AND
IS SHOWN FOR INFORMATION PURPOSES ONLY. THE CONTRACTOR
SHALL VISIT THE SITE PRIOR TO BIDDING TO FAMILIARIZE HIMSELF
WITH THE PROJECT AREA.
3. USE ID NUMBERS SHOWN ON MAPS TO FIND CORRESPONDING
APN NUMBER IN TABLE. APN NUMBERS CAN BE ENTERED AT THE
FOLLOWING WEBSITE TO FIND PARCEL OWNERSHIP INFORMATION:
https://gis.santacruzcountyaz.gov/asr/index.html
NOTE THAT THE APN NUMBER MUST BE ENTERED INTO THE
WEBSITE WITHOUT ANY DASHES.
4. SEE SHEET III-GI-0002 FOR ABBREVIATIONS.
5. SEE SHEET III-GI-0003 FOR GENERAL NOTES.
ID NUMBER APN NUMBER
APN NUMBERS TABLE
102-01-015A
102-01-015B
102-01-210A
(SEE NOTE 3)
102-01-210B
102-01-006E
102-01-006H
102-01-006M
ID NUMBER APN NUMBER
102-06-004
102-06-006
102-06-007
102-01-008C123
102-01-014124
102-01-015A125
102-01-038130
102-01-075131
102-01-076A132
102-01-006K121
102-01-016128
102-01-076B133
102-01-081135
PARCEL 102-01-076A EXHIBIT 3
Sainz Property 1982 N. Smokey Ln ra w n by
D es ig ne d by
R ev ie w ed b y:
D at e:
S ub m itt ed b y:
D es cr ip tio n
D at e A ct io n
S ol ic ita tio n
N o.
C on tr ac t N o.
R ev
Sheet Reference Number:
F ile
N am e:
P lo t D at e:
P lo t S ca le
S ym bo l
L:
\A
G E
\P ro je ct s\
IN
F R
\ib w c\
IB
W C
E ng in ee rin g
S er vi ce s\ T as k
O rd er
IB
M
T
N og al es
IO
I\0
8- D ra w in gs
\P ha se
D es iig n\
P la n S he et s\
-G C
-S H
E E
T S
\II
I-
G C
-1
1-
.d tte d:
W ed ne sd ay
, M ay
9, :0 0:
P
M
T ra ck in g N o.
/2 6/
III
-G
C -1
1-
.d w g
P R
O
JE
C T
N O
. 4
U R
S C
O R
P O
R A
T
IO
N
E
A S
T W
E T
M O
R E
R O
A D
S
U
IT
E
T
U C
S O
N , A
Z
(5
7-
U .S
. I N
T E
R N
A T
IO
N
A L
B O
U N
D A
R Y
W
A T
E R
C O
M M
IS
S
IO
N
N O
G A
LE
S
, A Z
IB
M
D
S
LS
S
LS
T S
S
C H
A R
LE
S
P E
D R
I, P
.E
/2
6/
A S
N O
T E
D
R E
H A
B
IL
IT
A
T
IO
N
IM
P R
O V
E M
E N
T S
T R
U N
K
LI
N E
A N
D
IN
T E
R N
A T
IO
N
A L
O U
T F
A
LL
IN
T
E R
C E
P T
O R
, S A
N T
A C
R U
Z C
O U
N T
Y , A
Z P
H A
S E
II
I
MH #42
MH #43
MH #44
MH #45
MH #46
MH #47
MH #41
MH #40
PHASE III PROJECT
BEGIN CIPP PIPING
CL MH # 37
STA 112+39.39
N=131838.51 E=1008203.91
PHASE III PROJECT
BEGIN BYPASS PIPING
CL MH # 36A
STA 112+00.00
N=131800.36 E=1008194.36
MH #39
MH #44-A1 MH #44-A
MH #44-B
MH #44-C
III-GC-1001
G E
N E
R A
L A
R R
A N
G E
M E
N T
S H
E E
T
O F
N GRAND AVE
N GRAND AVE
N GRAND AVE
N
D E
T E
N T
IO
N
R D
N HOHOKAM DR
N SMOKEY LN
E C
A
LL
E S
O N
O R
A
E B
A F
F E
R T
D R
E T
E R
M
IN
A L
P R
O D
U C
E D
R
E B
A
FF
E R
T D
R
E M
A Y
R A
D R
126 124
N SMOKEY LN
M A
T C
H L
IN
E
S T
A
MATCH LINE STA 161+50
M A
T C
H L
IN
E
S T
A
UNION PACIFIC NOGALES BRANCH RR
UNION PACIFIC NOGALES BRANCH RR
RR ROW
RR ROW
RR ROW
RR ROW
RR ROW
RR ROW
RR ROW
N GRAND AVE
HORIZONTAL
SSx
SSx
MH #35
MH #34
SSx
MH #36
N HOHOKAM DR
POTENTIAL BYPASS PUMP
STATION LOCATION
MH #37A
MH #38
LEGEND
PROPOSED CURED IN PLACE PIPE
PROPOSED BYPASS PIPE LINE
PROPOSED TRUNKLINE AND IOI
PIPE LINE EASEMENT
EXISTING STORM SEWER MAIN
EXISTING RAILROAD RIGHT OF WAY
EXISTING PARCEL LINE
EXISTING STORM MANHOLE
PL
BYP
PLE
SSx
RR ROW
NOTES:
1. PARCEL DATA PROVIDED BY GEOGRAPHIC MAPPING APPLICATION
AND SANTA CRUZ COUNTY GIS. PARCEL BOUNDARIES ARE
APPROXIMATE. HORIZONTAL COORDINATES: NAD83.
2. THE AERIAL IMAGE MAY NOT REFLECT EXISTING CONDITIONS AND
IS SHOWN FOR INFORMATION PURPOSES ONLY. THE CONTRACTOR
SHALL VISIT THE SITE PRIOR TO BIDDING TO FAMILIARIZE HIMSELF
WITH THE PROJECT AREA.
3. USE ID NUMBERS SHOWN ON MAPS TO FIND CORRESPONDING
APN NUMBER IN TABLE. APN NUMBERS CAN BE ENTERED AT THE
FOLLOWING WEBSITE TO FIND PARCEL OWNERSHIP INFORMATION:
https://gis.santacruzcountyaz.gov/asr/index.html
NOTE THAT THE APN NUMBER MUST BE ENTERED INTO THE
WEBSITE WITHOUT ANY DASHES.
4. SEE SHEET III-GI-0002 FOR ABBREVIATIONS.
5. SEE SHEET III-GI-0003 FOR GENERAL NOTES.
ID NUMBER APN NUMBER
APN NUMBERS TABLE
102-01-015A
102-01-015B
102-01-210A
(SEE NOTE 3)
102-01-210B
102-01-006E
102-01-006H
102-01-006M
ID NUMBER APN NUMBER
102-06-004
102-06-006
102-06-007
102-01-008C123
102-01-014124
102-01-015A125
102-01-038130
102-01-075131
102-01-076A132
102-01-006K121
102-01-016128
102-01-076B133
102-01-081135
PARCEL 102-01-076A EXHIBIT 4
Sainz Property 1982 N. Smokey Ln
Existing City of Nogales sewer pipeline easement
Requested temporary easement location
133133133
SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx SSx
SS x
SS x
144+00 145+00 146+00 147+00 148+00 149+00 150+00 151+00 152+00 153+00 154+00
155+00
156+00 x
ExExEx
E x
ExExExExExEx
E x
E x
E x
E x
ExExExExExX
X X X
X X
X X
X X
XX
PARKING LOT
PAVED LOADING DOCK
PARKING LOTPARKING LOT
PARKING LOT
BYP BYP BYP
BYP
BYP
BYP
BYP
BYP
BYP
BYP
BYP
BYP
BYP
BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP BYP
S S x
SS x
S S x
SS
x
S S x
S S x
S S x
S S S S S
T E
M P
O R
A R
Y C
O N
S T
R U
C T
IO
N
III-GC-1003
HORIZONTAL
D ra w n by
D es ig ne d by
R ev ie w ed b y:
D at e:
S ub m itt ed b y:
D es cr ip tio n
D at e A ct io n
S ol ic ita tio n
N o.
C on tr ac t N o.
R ev
Sheet Reference Number:
F ile
N am e:
P lo t D at e:
P lo t S ca le
S ym bo l
L:
\A
G E
\P ro je ct s\
IN
F R
\ib w c\
IB
W C
E ng in ee rin g
S er vi ce s\ T as k
O rd er
IB
M
T
N og al es
IO
I\0
8- D ra w in gs
\P ha se
D es iig n\
P la n S he et s\
-G C
-S H
E E
T S
\II
I-
G C
-1
3.
dw tte d:
W ed ne sd ay , M ay
9, :0
5:
P M
T ra ck in g N o.
/2 6/
III
-G
C -1
3.
dw g
P R
O
JE
C T
N O
. 4
U R
S C
O R
P O
R A
T
IO
N
E
A S
T W
E T
M O
R E
R O
A D
S
U
IT
E
T
U C
S O
N , A
Z
(5
7-
U .S
. I N
T E
R N
A T
IO
N
A L
B O
U N
D A
R Y
W
A T
E R
C O
M M
IS
S
IO
N
N O
G A
LE
S
, A Z
IB
M
D
S
LS
S
LS
T S
S
C H
A R
LE
S
P E
D R
I, P
.E
/2
6/
A S
N O
T E
D
R E
H A
B
IL
IT
A
T
IO
N
IM
P R
O V
E M
E N
T S
T R
U N
K
LI
N E
A N
D
IN
T E
R N
A T
IO
N
A L
O U
T F
A
LL
IN
T
E R
C E
P T
O R
, S A
N T
A C
R U
Z C
O U
N T
Y , A
Z P
H A
S E
II
I
CL UNION PACIFIC NOGALES BRANCH (200' R.O.W.)
R.R. R.O.W.
PLAN
STA. 144+00.00 TO STA. 156+00.00
POTENTIAL BYPASS
PIPELINE ALIGNMENT
PIPELINE EASEMENT
POINT "A"
CL MH 44-A1
STA = 144+42.45
N=134961.90 E=1008114.54
40' WIDE EASEMENT
NOTES:
1. SEE SHEET III-GI-0002 FOR LEGEND AND ABBREVIATIONS.
2. SEE SHEET III-GI-0003 FOR GENERAL NOTES.
R.R. R.O.W.
R.R. R.O.W.
R.R. R.O.W.
CL MH 44-A
STA = 147+91.14
N=135303.46 E=1008044.36
CL MH 44-B
STA = 149+91.66
N=135499.88 E=1008004.09
CL MH 44-C
STA = 151+46.69
N=135651.54 E=1007971.94
CL MH 45
STA = 154+65.58
N=135963.56 E=1007906.08
EXISTING 201.1 LF 30" RCP
EXISTING 318.9 LF 30" RCP
EXISTING 155.0 LF 30" RCPEXISTING 200.5 LF 30" RCP
EXISTING 348.7 LF 30" RCP
E . C
A
LL
E S
O N
O R
A
E . C
A
LL
E S
O N
O R
A
P.O.B.TCE EASEMENT
N=134997.80 E=1008081.64 N 13°- 36'- 35" W
L=139.13'
N 21°- 20'- 48" W
L=97.60'
N 12°- 29'- 11" W L=105.72'
N 00°- 00'-00" WL=178.63'N 14°- 04'- 52" W
L=245.39' N 16°- 57'- 37" W
L=108.34'
N 24°- 08'- 57" W
L=199.75'
S 11°- 36'- 40" E L=306.90'
S 11°- 35'- 08" E L=200.35'
S 11°- 58'- 15" E L=155.05'
S 11°- 55'- 06" E L=312.59'
S 78° 23' 20" W L=25.0'
N 11°- 36'- 40" W L=41.79'
S 40°- 1 0'- 5
7" E
L=101.40'
III
E
A S
E M
E N
T
III - 1TCE
PARCEL 102-01-076A EXHIBIT 4
Requested temporary easement location
Existing City of Nogales sewer pipeline easement
SSSSx SSSx
000000 149+00
XXXX XX XX
+0
ExEx
BYPBYP BYP BYPBYP BYPBYP BYP
S 11°- 35'- 08" E8 E L=200.35'200.3L=200 35'
BYPP B
Sainz Property 1982 N. Smokey Ln
ENCLOSURE 1
AFFIDAVIT OF LANDOWNER
STATE OF ARIZONA
COUNTY OF SANTA CRUZ
do hereby state as foltows:
I. I. , attest that I am the owner of the property Located at:
/k ti (Subject Property).
2. I attest that I have entered an agreement (see attachment) and given my consent to the USIBWC to access the Subject Property for a repair project to a pipeline.
3. I have tenant(s) on the Subject Property.
4. I have coordinated and informed the tenant(s) of the access that I have granted to USIBWC for the repair of the pipeline.
5. The tenant(s) is/are aware of the USIBWC’s access rights and no additional agreement is required between USIBWC and the tenant(s) to allow USIBWC to access the Subject Property.
I am voluntarily and freely signing this…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .