17-2026-03-19 - BID SET Combined.pdf
PDF 34 MB Posted
- Attached to
- Par 3 Restroom Renovation
- Solicitation number
- ITB No. 2026-025
- Issued by
- Palm Beach County, Florida
About this file
This is a Bid Set combined drawing document prepared for the Town of Palm Beach, Florida for the Par III Restroom Renovation project located at 2345 South Ocean Boulevard, Palm Beach, Florida. The project involves comprehensive interior and exterior renovations to a restroom facility at the Par 3 Golf Course, including the creation of ADA-compliant men's and women's restrooms, a unisex restroom, and a janitor's closet with a total renovation area of approximately 302 square feet. The project scope encompasses architectural, civil, structural, mechanical, electrical, and plumbing work, with construction scheduled to commence by July 7, 2026, achieve substantial completion by the end of September 2026, and final completion by October 15, 2026. A mandatory pre-bid meeting and site visit will be held at the facility prior to bid submission. The project includes demolition of existing interior walls, fixtures, and infrastructure; new exterior access with ADA-compliant sidewalk and curb modifications; installation of new mechanical, electrical, and plumbing systems; and finishes including porcelain tile flooring, tile wall surfaces, and specialized fixtures and accessories. The estimated project budget is $232,000.00, with bids to be submitted online through the Town's Euna Procurement (Bonfire) platform.
Selected contractors must hold a valid General Contract License and be certified as both an Electrical Contractor and Plumbing Contractor in the State of Florida. The Town reserves the right to award the contract to the lowest responsive and responsible bidder or to reject any and all bids at its discretion. The contract will be awarded based on meeting specified requirements and criteria, with the Town prioritizing the bidder who best serves its interests. AIA Document A201 will govern the General Conditions of the Contract, with the Town of Palm Beach designated as the Owner and PGAL Architects designated as the Architect. Funding and appropriations are provided by the Town of Palm Beach. The design and construction documents have been prepared by multiple consultants including PGAL Architects, Chenmoore and Associates (Civil), Johnson Structural Group (Structural), and CMTA (Mechanical, Electrical, and Plumbing).
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET NUMBER
SHEET TITLE
REGISTRATION
DRAWING HISTORY
PROJECT NUMBER
F
IL
E N
A M
E
D A
T E
S T
A M
P
SAN DIEGO
SALT LAKE CITY
LOS ANGELES
LAS VEGAS
HOUSTON
HOBOKEN
DENVER
DFW
BOCA RATON
AUSTIN
ATLANTA
ALEXANDRIA
ARCHITECTURE
ENGINEERING
INTERIORS
PLANNINGProject State Registration #: 123789456
C
R e v it L o c a ls
\P A
R I
II
R a m ila n iA
R S
D
.r v t
/1
/2
:4
:1
A
M
G0.00
COVER SHEET
1008335.00
Copyright © 2025
Par III Restroom Renovation
2026/02/23
2345 South Ocean Blvd Palm Beach, FL 33480
BID SET
SHEET INDEX
Sheet № Sheet Name Current Revision
Date Current Revision Description
General
G0.00 COVER SHEET
G0.02 GENERAL PROJECT INFORMATION 2026/03/19 BID SET
G0.10 ADA STANDARDS 2026/03/19 BID SET
G1.01 CODE ANALYSIS - LIFE SAFETY PLAN 2026/03/19 BID SET
Civil
C1.00 CIVIL IMPROVEMENTS 2026/03/19 BID SET
C2.00 IMPROVEMENTS 2026/03/19 BID SET
Architecture
A0.02 FIXTURES AND ACCESSORIES TYPICAL MOUNTING HEIGHTS 2026/03/19 BID SET
A0.10 PARTITION TYPES 2026/03/19 BID SET
A0.30 DOOR SCHEDULES & ASSEMBLY TYPES 2026/03/19 BID SET
A1.01 SITE PLAN 2026/03/19 BID SET
A2.01 FLOOR PLAN 2026/03/19 BID SET
A3.01 REFLECTED CEILING PLAN 2026/03/19 BID SET
A6.00 EXTERIOR ELEVATIONS & SECTIONS 2026/03/19 BID SET
A8.00 INTERIOR ELEVATIONS 2026/03/19 BID SET
A8.50 MILLWORK DETAILS 2026/03/19 BID SET
Demolition
AD2.01 DEMO FLOOR PLAN AND CEILING PLANS 2026/03/19 BID SET
Structural
S1.0 STRUCTURAL NOTES AND DETAILS 2026/03/19 BID SET
S2.0 STRUCTURAL PLANS 2026/03/19 BID SET
S3.0 STRUCTURAL BUILDING SECTIONS 2026/03/19 BID SET
Mechanical
M0.01 GENERAL NOTES - HVAC 2026/03/19 BID SET
M0.11 SITE PLAN - HVAC 2026/03/19 BID SET
MD1.01 FLOOR PLAN - DEMO - HVAC 2026/03/19 BID SET
M1.01 FLOOR PLAN - PROPOSED - HVAC 2026/03/19 BID SET
M3.01 DETAILS & SCHEDULES - HVAC 2026/03/19 BID SET
Electrical
E0.01 GENERAL NOTES - ELECTRICAL 2026/03/19 BID SET
E0.10 SITE PLAN - ELECTRICAL 2026/03/19 BID SET
ED1.01 FLOOR PLAN - DEMO - LIGHTING 2026/03/19 BID SET
ED2.01 FLOOR PLAN - DEMO - POWER 2026/03/19 BID SET
E1.01 FLOOR PLAN - PROPOSED - LIGHTING 2026/03/19 BID SET
E2.01 FLOOR PLAN - PROPOSED - POWER 2026/03/19 BID SET
E6.01 ONE LINE DIAGRAM & PANEL SCHEDULE - ELECTRICAL 2026/03/19 BID SET
Plumbing
P0.01 GENERAL NOTES - LEGEND & SPECS - PLUMBING 2026/03/19 BID SET
PD1.01 FLOOR PLAN - DEMO - PLUMBING 2026/03/19 BID SET
P1.01 FLOOR PLAN - PROPOSED - PLUMBING 2026/03/19 BID SET
P3.01 DETAILS & SCHEDULES - PLUMBING 2026/03/19 BID SET
CLIENT
Palm Beach Par III Golf Course
2345 South Ocean Blvd Palm Beach, FL 33480
T 561-547-0598
ARCHITECT
PGAL, Inc.
791 Park of Commerce Blvd Suite 400 Boca Raton, FL 33487 T 561-988-4002
CIVIL
Chenmoore and Associates
500 Australian Avenue Suite 850 West Palm Beach, FL 33401 T 561-746-6900
STRUCTURAL
Johnson Structural Group
160 West Camino Real Suite 1000 Boca Raton, FL 33432 T 561-982-8999
MEP
CMTA
2 Harvard Circle Suite 100 West Palm Beach, FL 33409 T 561-547-0598
LOCATION MAP
№. DATE DESCRIPTION
ALIGN ALIGN
AV
J
AV
AV
AV
AV
AV
AV
AV
AV AV
AV
AV
AV
AV
AV
AV
AV
AV
AV
01 / A6.00
SIM
01 / A8.00
SIM
A8.00
01 SIM
01 SIM
SI
M
SI
M
View Number
Sheet Number
Reference
View Number
Sheet Number
Reference
EXTERIOR ELEVATION REFERENCE
INTERIOR ELEVATION REFERENCE
Sheet Number
Reference
BUILDING / WALL SECTION REFERENCE
INTERIOR SECTION REFERENCE
01 / A2.01
SIM
01 / A2.01
SIM.
View Number
Sheet Number Reference
01 / A4.01
SIM
ENLARGED PLAN / DETAIL CALLOUT REFERENCE
View Number
Sheet Number
Reference
1010 Column Grid Reference
New Existing
Column Centerline
COLUMN GRIDLINES
Name Elevation
LEVEL HEAD
10' - 6"
SPOT ELEVATION
Elevation
N 1' - 0" E 1' - 0"
SPOT COORDINATE
Coordinates
MATCHLINE VIEW REFERENCE
View Number
Sheet Number
Reference Direction
MATCHLINE
REF: 01 / A2.01B
NORTH ARROW
View Number
Sheet Number Reference
Magnetic North Indicator
Project North Indicator
0 4'-0" 8'-0" 16'-0"
GRAPHIC SCALE
CL
+6"
0"
FLOOR FINISH TRANSITION
FLOOR ELEVATION CHANGE
ALIGN SYMBOL
CENTERLINE
EXIT SIGN
A
SHEET NOTE CALLOUT
150 SF
CLASS
1:###
Area Name
##" REQ.
Stair Number
Width Factor
### OCC
Occupancy Class
Square Footage
Occupant Load
Load Ratio
Required Clear Width
Occupant Load
Egress Cumulative Load
Egress Exit Load
Required Clear Width
Provided Clear Width
Occupant Load
Common Travel Path
Egress Travel Path
Exit Number
### OCC
Width Factor
REQ
Provided Clear Width
AB-1
OFFICE
M33.3▐
W12
10'-6"
ROOM TAG
PARTITION TAG
WINDOW / LOUVER TAG
DOOR TAG
Partition Type
Batt Indicator
Room # Room Name
Window / Louver Type
Door #
CASEWORK TAG
CEILING HEIGHT TAG
REVISION TAG
FURNITURE / FURNITURE SYSTEM TAG
EQUIPMENT TAG
30WB01
34H24D
AREA TAG
Room Area (SF)
Area Name
Area Area (SF)
Revision #
Height Above Finish Floor
Area Name
Area Area (AC)
Casework Depth
Casework Height
Casework Type
Casework Width
AREA NAME
1,250 SF
AREA NAME
20.05 AC
Furniture Type
Furniture System Type1i
Equipment Type1i
101A
PT-01
RB-01
PT-01
Wall Finish Code
Finish Code
FINISH TAG
Base Finish Code
Wall Indicator Arrows (Optional)
WALL & BASE FINISH TAG
ROOM FINISH TAG
Ceiling Finish Code Wall Finish Code Base Finish Code Floor Finish Code
C
B W
F CP-01
RB-01
PT-01
ACT-01
WALL RECEPTACLE SYMBOLS
Quadplex 4-way Dedicated Circuit Receptacle
Quadplex 2-way Dedicated Circuit Receptacle
Quadplex 4-way Separate Circuit Receptacle
Quadplex 2-way Separate Circuit Receptacle
Quadplex Convenience Receptacle
Duplex Dedicated Circuit Receptacle
Duplex Separate Circuit Receptacle
Quadplex Dedicated Circuit Receptacle
Duplex Convenience Receptacle
220v Monoplex Receptacle
Data Receptacle
Voice Receptacle
Combination Data / Voice Receptacle
AV Receptacle
Junction Box
FLOOR RECEPTACLE SYMBOLS
Quadplex Convenience Receptacle Flush Mount
Quadplex Convenience Receptacle Surface Mount
Duplex Convenience Receptacle Flush Mount
Duplex Convenience Receptacle Surface Mount
220v Monoplex Convenience Receptacle Flush Mount
220v Monoplex Convenience Receptacle Surface Mount
Data Receptacle Flush Mount
Data Receptacle Surface Mount
Voice Receptacle Flush Mount
Voice Receptacle Surface Mount
Combination Data / Voice Receptacle Flush Mount
Combination Data / Voice Receptacle Surface Mount
AV Receptacle Flush Mount
AV Receptacle Surface Mount
COMBINATION FLUSH MOUNT FLOOR RECEPTACLE SYMBOLS
COMBINATION SURFACE MOUNT FLOOR RECEPTACLE SYMBOLS
NEW 1 HR. RATED CONSTRUCTION
NEW 2 HR. RATED CONSTRUCTION
NEW 3 HR. RATED CONSTRUCTION
NEW 4 HR. RATED CONSTRUCTION
NEW 30 MIN. RATED CONSTRUCTION
NEW CONSTRUCTION
EXISTING TO REMAIN CONSTRUCTION
EXISTING CONST. TO BE DEMOLISHED
T it le
B a r
30" x 42" Sheet without Note Bar
Note Bar
T it le
B a r
30" x 42" Sheet with Horizontal Note Bar
N o te
B a r
T it le
B a r
30" x 42" Sheet with Vertical Note Bar
Each view is assigned detail numbers starting in the lower right corner of the sheet.
The number of each drawing is determined by the location of the lower right corner of the drawing. This number will always have its designated positions but may vary based on whether a Note Bar is included and its orientation. The total number of cells will vary depaending of sheet size. Additionally, drawings can occupy a single grid cell or span multiple cells.
SHEET NUMBER
SHEET TITLE
CLIENT
ARCHITECT
CONSULTANT
PROJECT NAME
PROJECT LOCATION
PROJECT NUMBER
561-988-4002 www.pgal.com
Suite 400
791 Park of Commerce Boulevard
PGAL, Inc.
Boca Raton, FL 33487
Chenmoore and Associates
500 Australian Avenue
Suite 850
West Palm Beach, FL 33401
T 561-746-6900
F
IL
E N
A M
E
D A
T E
S T
A M
P
Johnson Structural Group
160 West Camino Real
Suite 1000
Boca Raton, FL 33432
T 561-982-8999
REGISTRATION
DRAWING HISTORY
CMTA
4 Harvard Circle
Suite 600
West Palm Beach, FL 33409
T 561-547-0598
C
R e v it L o c a ls
\P A
R I
II
R a m ila n iA
R S
D
.r v t
/1
/2
:4
:2
A
M
G0.02
GENERAL PROJECT
INFORMATION
Par III Restroom Renovation
2345 South Ocean Blvd Palm Beach, FL 33480
1008335.00
Town of Palm Beach Palm Beach Par III Golf Course
T 561-547-0598
Copyright © 2025
2345 South Ocean Blvd Palm Beach, FL 33480
GENERAL PROJECT SYMBOLS
LIFE SAFETY SYMBOLS & TAGS
STANDARD PROJECT TAGS
POWER & COMM SYMBOLS
ABBREVIATIONS
WALL GRAPHIC LEGEND DETAIL NUMBERING
ABBREV DESCRIPTION
A ABV above ACOUS acoustical ACT acoustical ceiling tile AD area drain ADJ adjustable AFF above finished floor ALT alternate ALUM aluminum APPROX approximate ARCH architect
B B.O. bottom of BALC balcony BD board BET between BLDG building BLKG blocking BLW below BM beam BOT bottom BRKT bracket BULKHD bulkhead BUR built up roof
C C.G. corner guard CAB cabinet CALK caulking CEM cement CER ceramic CJ control joint CLG ceiling CLOS closet CLR clear CO cased opening COL column CONC concrete CONT continous CPT carpet CT ceramic tile CTR center
D DBL double DET detail DIA diameter DIM dimension DN down DR door DS down spout DW dishwasher DWG drawing
E E east EA each EIFS exterior insulation & finish system ELEC electric(al) ELEV elevation EMER emergency ENCL enclosure EOS edge of slab EQ equal EQUIP equipment ETR existing to remain EW each way EXP. JT. expansion joint EXST existing
F F.O. face of FA fire alarm FAP fire annunciuator panel FD floor drain FE fire extinguisher FEC fire extinguisher cabinet FG finish group FH fire hydrant FHC fire hose cabinet FIN finish FLR floor FLUOR fluorescent FT foot or feet FUR furring
G GAL gallon GALV galvanized GB grab bar GC general contractor GL glass GND ground GWB gypsum board GYP gypsum
H H.W.H. hot water heater HC handicapped HDWD hardwood HDWR hardware HM hollow metal HORIZ horizontal HR hour HT height
I ID inner diameter INCAN incandescent INSUL insulation INT interior
J JAN janitor JST joist
ABBREV DESCRIPTION
JT joint
L LAM laminate LAV lavatory LB(S) pounds LDG landing LT light
M MAX maximun MECH mechanical MEMB membrane MFR manufacturer MIN minimum MISC miscellaneous MO masonry opening MTD mounted MTL metal
N N north NIC not in contract NO number NOM nominal NTS not to scale
O O.P. overflow pipe OA overall OC on center OD outside diameter OFF office OH opposite hand OPG opening OPP opposite
P PART partition PERM perimeter PG paint grade PLAM plastic laminate PLAS plaster PLYWD plywood PR pair PT paint PTD painted
R R riser RAD radius RCP reflected ceiling plan RD roof drain RE refer REF refrigerator REINF reinforced REQD required RESIL resilient RM room RO rough opening RTU root top unit (mech)
S S south SAFB sound attenunation fiber batt SC scupper SCHED schedule SEAL sealant SECT section SF square foot SHT sheet SIM similar SPEC specification SQ square SS stainless steel STD standard STL steel STOR storage STRUCT structural SUSP suspended SYM symmetrical
T T tread T&G tongue & groove TEL telephone TER terrazzo THK thick THR threshold TO top of TYP typical
U UC undercut UNFIN unfinished UNO unless noted otherwise UON unless otherwise noted UTIL utility
V VCT vinyl compostion tile VERT vertical VIF verify in field VTR vent termination pipe VWC vinyl wall covering
W W west W/ with W/O without WC watercloset WIN window WP waterproof WS wetstack WSCT wainscot WT weight
№. DATE DESCRIPTION
A 2026/03/19 BID SET
1. THE CONSTRUCTION DOCUMENTS ARE TO INCLUDE AIA DOCUMENT A201 “GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION.” TOWN OF PALM BEACH SHALL BE DESIGNATED AS THE OWNER, PGAL ARCHITECTS SHALL BE DESIGNATED AS THE ARCHITECT. THE AIA DOCUMENT SHALL ALSO INCLUDE THE AGREEMENT, PERFORMANCE AND PAYMENT BONDS, GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, THE SPECIFICATIONS, THE DRAWINGS, ADDENDUM, AND CONTRACT MODIFICATIONS, BUILDING RULES AND
REGULATIONS, AND ANY OTHER DOCUMENTS REQUIRED BY THE OWNER.
2. THE GENERAL CONTRACTOR SHALL BE BOTH LICENSED AND BONDED IN THE STATE OF FLORIDA AND SHALL
PROVIDE DOCUMENTS UPON REQUEST.
3. THE WORK SHALL BE DONE IN ACCORDANCE WITH THE RULES AND REGULATIONS OF ALL APPLICABLE SAFETY AND BUILDING CODES, AND AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING AND PAYING FOR ALL PERMITS REQUIRED FOR THE WORK AND FOR THE
SCHEDULING OF ALL REQUIRED INSPECTIONS DURING THE COURSE OF THE WORK.
4. THE GENERAL CONTRACTOR SHALL REVIEW AND VERIFY EXISTING CONDITIONS AS PROVIDED IN THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ALL DISCREPANCIES, ERRORS, INCONSISTENCIES OR AMBIGUITIES PRIOR TO PROCEEDING WITH THE WORK.
5. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR, AND PROVIDE PROTECTION OF, ANY EXISTING FINISHES, MATERIALS, AND EQUIPMENT TO REMAIN. THE GENERAL CONTRACTOR SHALL REPAIR OR REPLACE ANY DAMAGED FINISHES, MATERIALS, AND EQUIPMENT AS A RESULT OF THE WORK. ALL EXISTING FINISHES TO REMAIN SHALL BE CLEANED AT THE COMPLETION OF CONSTRUCTION. THE GENERAL CONTRACTOR SHALL PHOTOGRAPH AND DOCUMENT ALL EXISTING DAMAGES, AND PROVIDE TO THE ARCHITECT, PRIOR TO PROCEEDING WITH THE
WORK.
6. ALL MATERIALS AND SYSTEMS SHALL BE INSTALLED PER MANUFACTURER’S SPECIFICATIONS. ALL CONSTRUCTION SHALL BE OF INDUSTRY STANDARD OR BETTER. THE ARCHITECT SHALL BE FINAL JUDGE OF QUALITY.
7. ONLY NEW MATERIALS AND EQUIPMENT OF RECENT MANUFACTURE, OF STANDARD QUALITY AND FREE FROM DEFECTS, SHALL BE PERMITTED IN THE WORK, UNLESS OTHERWISE NOTED. REJECTED MATERIALS AND EQUIPMENT SHALL BE REMOVED IMMEDIATELY FROM THE WORK AND REPLACED WITH MATERIALS AND EQUIPMENT OF THE QUALITY SPECIFIED. FAILURE TO REMOVE REJECTED MATERIALS AND EQUIPMENT SHALL NOT RELIEVE THE GENERAL CONTRACTOR FROM THE RESPONSIBILITY FOR QUALITY OF MATERIAL AND EQUIPMENT
USED NOR FROM ANY OTHER OBLIGATION IMPOSED BY THE CONTRACT.
8. DO NOT SCALE DRAWINGS. STATED & WRITTEN DIMENSIONS GOVERN. THE GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND SHALL BE RESPONSIBLE FOR THEIR ACCURACY. NO EXTRA CHARGE OR COMPENSATION SHALL BE ALLOWED BECAUSE OF DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THOSE INDICATED ON THE DRAWINGS, UNLESS THEY CONTRIBUTE TO A CHANGE IN THE SCOPE OF THE WORK. ANY DIFFERENCE FOUND SHALL BE SUBMITTED TO THE ARCHITECT FOR COORDINATION PRIOR TO ORDERING, MANUFACTURING, OR PROCEEDING WITH THE WORK. HORIZONTAL DIMENSIONS INDICATED ARE TO/FROM FACE OF FINISH, UNLESS NOTED OTHERWISE. VERTICAL DIMENSIONS ARE FROM TOP OF FLOOR SLAB EXCEPT WHERE NOTED TO BE ABOVE FINISHED FLOOR (AFF). DIMENSIONS ARE NOT ADJUSTABLE WITHOUT APPROVAL OF
ARCHITECT UNLESS NOTED.
9. IN THE EVENT OF CONFLICT BETWEEN DATA SHOWN ON DRAWINGS AND DATA PROVIDED IN THE SPECIFICATION, THE SPECIFICATION SHALL GOVERN. DETAIL DRAWINGS TAKE PRECEDENT OVER DRAWINGS OF LARGER SCOPE.
THE CONTRACTOR SHALL PROVIDE WRITTEN NOTIFICATION TO THE ARCHITECT OF ANY DISCREPANCIES, PRIOR TO PROCEEDING WITH THE WORK. IN CASE OF AN INCONSISTENCY BETWEEN DRAWINGS AND SPECIFICATIONS OR WITHIN EITHER DOCUMENT, NOT CLARIFIED BY ADDENDUM, THE MORE SPECIFIC PROVISION SHALL TAKE
PRECEDENCE.
10. THE GENERAL CONTRACTOR SHALL VERIFY THAT NO CONFLICTS EXIST BETWEEN THE LOCATIONS OF EXISTING AND PROPOSED NEW MECHANICAL, ELECTRICAL, PLUMBING, DATA, AND SPRINKLER EQUIPMENT (INCLUDING BUT NOT LIMITED TO STRUCTURAL MEMBERS, PIPING, DUCT WORK, CONDUIT AND SPRINKLERS) AND THAT CLEARANCES FOR INSTALLATION AND MAINTENANCE OF EQUIPMENT ARE PROVIDED. ELEMENTS IN CONFLICT SHALL BE DOCUMENTED AND PROVIDED TO THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK.
11. THE GENERAL CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH SHOP DRAWINGS FOR REVIEW AND APPROVAL, FOR ALL, BUT NOT LIMITED TO, THE FOLLOWING: SHOP-FABRICATED MILLWORK, CARPET LAYOUT, FLOORING, LIGHT FIXTURES, DOORS, MISC. STEEL, METAL FABRICATION, GLASS/GLAZING, SPRINKLER LAYOUTS, HARDWARE. SHOP DRAWINGS SHALL BE SUBMITTED ELECTRONICALLY VIA PDF DOCUMENT. SHOP DRAWINGS SHALL NOT BE REPRODUCTIONS OF CONTRACT DOCUMENTS. MATERIAL SUBMITTALS (3 SAMPLES) SHALL BE PROVIDED FOR WOOD, FASTENERS, ACRYLIC, CARPET, TILE, BASE, PAINT, LAMINATE AND ANY OTHER MATERIALS
INDICATED IN THE SHOP DRAWINGS.
12. THE GENERAL CONTRACTOR SHALL PROVIDE THE ARCHITECT WITH MANUFACTURER’S CUT SHEETS AND SPECIFICATIONS FOR ALL EQUIPMENT INCLUDING BUT NOT LIMITED TO: LIGHT FIXTURES, PLUMBING EQUIPMENT, ELECTRICAL EQUIPMENT, FANS, SUPPLEMENTARY HEATING AND COOLING ELEMENTS AND HARDWARE AND
SECURITY EQUIPMENT.
13. THE GENERAL CONTRACTOR SHALL NOT PROCEED WITH WORK FOR WHICH HE EXPECTS ADDITIONAL COMPENSATION BEYOND THE CONTRACT AMOUNT WITHOUT WRITTEN AUTHORIZATION FROM THE ARCHITECT AND OWNER. FAILURE TO OBTAIN SUCH AUTHORIZATION SHALL INVALIDATE A CLAIM FOR EXTRA COMPENSATION.
THE CONTRACTOR SHALL NOT PROCEED WITH WORK WHICH, IF COMPLETED IN STRICT CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS, WILL RESULT IN ADDITIONAL WORK BEYOND THE SCOPE OF THE CONTRACT WITHOUT WRITTEN AUTHORIZATION FROM THE ARCHITECT AND OWNER. ANY FIELD CONDITIONS THAT SIGNIFICANTLY VARY FROM THE CONTRACT DOCUMENTS OR WILL RESULT IN ADDITIONAL WORK SHALL BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH WORK.
14. THE GENERAL CONTRACTOR SHALL INCLUDE ALL X-RAY AND CORE DRILL COSTS. THE GENERAL CONTRACTOR SHALL REVIEW AND COORDINATE THE SIZE AND LOCATION OF ALL SLAB OPENINGS WITH ALL RELATED DISCIPLINES. THE GENERAL CONTRACTOR SHALL SUBMIT PROPOSED LOCATIONS OF CORE DRILLING AND SLAB OPENINGS TO ARCHITECT AND STRUCTURAL ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO
PROCEEDING WITH THE WORK.
15. PATCH, REPAIR, AND INSTALL ALL FIREPROOFING AS REQUIRED BY CODE. FIREPROOF ALL NEW PENETRATIONS AS
REQUIRED FOR APPROVAL BY THE AUTHORITY HAVING JURISDICTION.
16. WHERE BUILDING SEISMIC JOINTS ARE LOCATED, THE GENERAL CONTRACTOR SHALL PROVIDE APPLICABLE CODE AND INDUSTRY BEST PRACTICES FOR ROUTING OF ALL PIPING, DUCTS, CONDUITS AND OTHER CONTINUOUS
RUNS.
17. THE GENERAL CONTRACTOR SHALL CONTINUOUSLY CHECK ARCHITECTURAL AND STRUCTURAL CLEARANCES FOR ACCESSIBILITY OF EQUIPMENT AND MECHANICAL AND ELECTRICAL SYSTEMS. NO ALLOWANCES OF ANY KIND WILL BE MADE FOR THE GENERAL CONTRACTOR’S NEGLIGENCE TO FORESEE MEANS OF INSTALLING EQUIPMENT
INTO POSITION.
18. THE FINISHED WORK SHALL BE FIRM, WELL-ANCHORED, IN TRUE ALIGNMENT, PLUMB, LEVEL, WITH SMOOTH, CLEAN, UNIFORM, APPEARANCE WITHOUT WAVES, DISTORTIONS, HOLES, MARKS, CRACKS, STAINS, OR DISCOLORATION. JOINTING SHALL BE CLOSE FITTING, NEAT AND WELL SCRIBED. THE FINISHED WORK SHALL HAVE NO EXPOSED UNSIGHTLY ANCHORS OR FASTENERS AND SHALL NOT PRESENT HAZARDOUS, UNSAFE CORNERS.
ALL WORK SHALL HAVE THE PROVISION FOR EXPANSION, CONTRACTION AND SHRINKAGE AS NECESSARY TO PREVENT CRACKS, BUCKLING, AND WARPING DUE TO TEMPERATURE AND HUMIDITY CONDITIONS.
19. ATTACHMENTS, CONNECTIONS OR FASTENERS OF ANY NATURE ARE TO PROPERLY AND PERMANENTLY BE SECURED IN CONFORMANCE WITH INDUSTRY BEST PRACTICES. THE DRAWINGS HIGHLIGHT SPECIAL CONDITIONS ONLY AND BY NO MEANS ILLUSTRATE EVERY CONNECTION. THE CONTRACTOR IS RESPONSIBLE FOR IMPROVING
CONNECTION ACCORDINGLY.
20. GENERAL CONTRACTOR SHALL WAIVE “COMMON PRACTICE” AND “COMMON USAGE” AS CONSTRUCTION CRITERIA WHEREVER DETAILS AND CONTRACT DOCUMENTS OF GOVERNING CODES, ORDINANCES, ETC. REQUIRE
QUANTITY OR BETTER QUALITY THAN COMMON PRACTICE OR COMMON USAGE WOULD REQUIRE.
21. THE GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND SUBMITTALS, AND SHALL ORDER AND SCHEDULE DELIVERY OF MATERIALS TO AVOID DELAYS IN CONSTRUCTION. IF AN ITEM IS FOUND TO BE UNAVAILABLE OR TO HAVE A LONG LEAD TIME, THE GENERAL CONTRACTOR SHALL NOTIFY ARCHITECT
IMMEDIATELY WITH A PROPOSED ALTERNATIVE.
22. THE GENERAL CONTRACTOR SHALL NOTIFY THE OWNER AND THE ARCHITECT IN WRITING OF ANY DEFICIENCIES IN BASE BUILDING WORK PRIOR TO THE COMMENCEMENT OF THE WORK. ANY UNREPORTED DEFICIENCIES WILL
BECOME THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CORRECT.
23. THE GENERAL CONTRACTOR SHALL EXERCISE INDUSTRY BEST PRACTICES FOR CARE AND CAUTION DURING THE CONSTRUCTION OF THE WORK, AND SHALL SCHEDULE WORK TO MINIMIZE DISTURBANCES TO OCCUPANTS, ADJACENT SPACES AND STRUCTURES, PROPERTY, PUBLIC THOROUGHFARES, ETC. THE GENERAL CONTRACTOR SHALL TAKE PRECAUTIONS AND BE RESPONSIBLE FOR THE SAFETY OF ALL BUILDING OCCUPANTS DURING CONSTRUCTION PROCEDURES. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY COSTS INCURRED.
24. ALL DEBRIS SHALL BE REMOVED FROM THE SITE ON A DAILY BASIS, OR AS DIRECTED BY THE AUTHORITY HAVING JURISDICTION. UPON COMPLETION OF THE WORK, REMOVE ALL DEBRIS FROM THE BUILDING CREATED BY THE WORK PROVIDED UNDER THIS CONTRACT AND LEAVE ALL AREAS CLEAN. TRASH IS NOT PERMITTED TO BE
BURNED ON SITE.
25. SLAB PENETRATIONS SHALL BE SEALED AS REQUIRED TO MAINTAIN FIRE RATING, IF APPLICABLE, USING
MATERIALS AND METHODS APPROVED BY THE AUTHORITY HAVING JURISDICTION.
26. ALL PENETRATIONS SHALL BE SEALED AS REQUIRED TO MAINTAIN FIRE RATING, IF APPLICABLE. USE MATERIALS
COMPATIBLE WITH THE AUTHORITY HAVING JURISDICTION’S REQUIREMENTS.
27. THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY ACCESS PANELS WHICH MAY BE REQUIRED PRIOR TO PROCEEDING WITH THE WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL
TRADES. REQUIRED ACCESS PANELS SHALL BE INCLUDED IN THE CONTRACT DOCUMENTS.
28. CONTRACTOR SHALL PROVIDE THE TEAM WITH A CONSTRUCTION SCHEDULE SHOWING THE PROPOSED PHASING.
LONG LEAD ITEMS THAT WILL AFFECT THE SUBSTANTIAL COMPLETION DATE SHALL BE BROUGHT TO THE
ARCHITECT’S ATTENTION IMMEDIATELY.
29. THE CONTRACTOR SHALL MAINTAIN SAFE PEDESTRIAN ACCESS TO THE FACILITY AND SURROUNDING GOLF COURSE AREAS AT ALL TIMES. COORDINATE TEMPORARY BARRIERS, DUST PROTECTION, AND STAGING WITH THE
OWNER.
30. ALL EXISTING UTILITIES SERVING AREAS OUTSIDE THE RENOVATION SCOPE SHALL REMAIN ACTIVE. PROVIDE
TEMPORARY CONNECTIONS AS REQUIRED TO MAINTAIN CONTINUOUS SERVICE.
31. MAINTAIN ALL LIFE SAFETY SYSTEMS ACTIVE AND OPERATIONAL THROUGHOUT CONSTRUCTION, INCLUDING EXIT
SIGNAGE, EMERGENCY LIGHTING, AND FIRE ALARM SYSTEMS.
GENERAL PROJECT NOTES
min max dimension showing English units (in inches unless otherwise specified) above the line and SI units (in millimeters unless otherwise specified) below the line dimension for small measurements direction of travel or approach boundary of clear floor space or maneuvering clearance centerline minimum maximum a permitted element or its extension a wall, floor, ceiling or other element cut in section or plan a highlighted element in elevation or plan
Convention Description location zone of element, control or feature greater than>
< less than
33-36
840-915 dimension showing a range with minimum -maximum less than or equal to greater than or equal to
LC
Graphic Convention for Figures
½ max
6.4 ¼ max 6.4 1
2¼
¼ 6.4
½
302.2 Carpet Pile Height 303.2 Vertical Change in Level 303.3 Beveled Change in Level dominant direction of travel long dimension perpendicular to dominant direction of travel
½ max
302.3 Elongated Openings in Floor or
Ground Surfaces
30 min
48 min m in m in
(a) forward
(b) parallel
36 min
X alcove forward
60 min
X alcove parallel m in
24 min m in
36 min
12 min
12 min
60 min base ar m ar m
304.3.2 T-Shaped
Turning Space
17-25
430-635 6 max m in
(a) elevation
(b) plan
11 min m in
8 min
9 min
(a) elevation
(b) plan m in
25 max
306.3 Knee Clearance
306.2 Toe Clearance
305.5 Position of Clear
Floor or Ground Space
305.7 Maneuvering
Clearance in an Alcove
4 max
X
X
12 max
12 max
-8
5-m a x m in
30X > 12
X > 12
(b)(a) m a x
5 20
X
307.4 Vertical Clearance
307.3 Post-Mounted Protruding Objects307.2 Limits of Protruding Objects m in m a x m a x m a x
>20-25 max
510-635 20 max
10 max m a x m in
10 max m a x m a x m a x m a x
> 10-24 max
255-610
(a) (b) m in
48 min
24 max m in m in m in
24 max
42 min m in
X < 48
42 min
X < 48
36 min
36 min m in
(a) 180 degree turn
(b) 180 degree turn
(Exception)
(c) folding door
(a) hinged door
(b) sliding door
32 min
32 min
32 min
404.2.3 Clear Width of Doorways
42 min
1065 5 m in
(e) hinge approach, pull side
36 min m in
(d) hinge approach, pull side
(g) hinge approach, push side, door provided with both closer and latch m in
20 22 min m in
22 min
(f) hinge approach, push side
(k) latch approach, push side, door provided with closer
24 min 12 m in
24 min m in
(j) latch approach, push side
24 min m in
(h) latch approach, pull side (i) latch approach, pull side, door provided with closer m in
70 610
24 min m in
18 min
(a) front approach, pull side m in
(b) front approach, push side m in12 min
(c) front approach, push side, door provided with both closer and latch m in
(a) front approach
(b) side approach m in
22 min m in
(c) pocket or hinge approach
24 min
61010 m in
(d) stop or latch approach
404.2.4.2 Maneuvering Clearance at
Sliding and Folding Doors m in
12 min
(c) push side, door provided with both closer and latch
X > 8 m in
(b) push side
X > 8
(a) pull side m in
18 min
X > 8
404.2.4.3 Maneuvering Clearance at
Recessed Doors and Gates
48 min
48 min
(a) (b)
48 min
(c) ramp run landinglanding
60 min
1525 1525 60 min landing ramp run ra m p r u n
60 min m in at least as wide as ramp run
(a) straight
(b) change in direction
30° max
(c) curved nosing
(d) beveled nosing
(b) angled riser
1½ max 1½ max
(a) radius of tread edge
(typical for all profiles) radius ½ max
-3
5-
(a) stairs
(b) ramps
5-
-3
(c) walking surfaces
-3
5-
5 38
1½ min
½ m in
505.6 Horizontal Projections Below
Gripping Surface
505.5 Handrail Clearance
100-160 4-6¼ perimeter
(a) (b)
2¼ max
572¼ m ax
12 min
12 min
12 min
505.10.3 Bottom Handrail
Extension at Stairs 505.10.2
Top Handrail Extension at Stairs
505.10.1 Top and Bottom Handrail
Extension at Ramps x x
5 max 15 min
380125
16-18
405-455 430-485 17-19
(a) wheelchair accessible water closets
(b) ambulatory accessible water closets
LC CL
602.5 Drinking Fountain
Spout Locatio
60 min m in
604.3.1 Size of Clearance at Water Closets
604.2 Water Closet Location
12 max
42 min
54 min
604.5.1 Side Wall Grab Bar at
Water Closets
LC
transfer side
12 min
24 min
36 min
604.5.2 Rear Wall Grab Bar at
Water Closets
LC
m in
7-9
180-230 m a x
604.7 Dispenser Outlet Location
(a) elevation adult
9 min
6 min partition
6 min
6 min
(c) plan
6 min
(b) elevation children
12 min partition
604.8.1.4 Wheelchair Accessible Toilet
Compartment Toe Clearance
(b) stall type
(a) wall hung type
17 max
13½ min 13½ min
605.2 Height and Depth of Urinals
ALLOWABLE REACH
RANGE FROM SIDE
APPROACH (ONLY IF
POSSIBLE)
M
IN
1'
3"4'
0" M
AX
3'
0"
4'
0" M
AX
T
O
CO
IN
S
LO
T
3'
2"
TO
B
UT
TO
N
4'
0"
TO
S
LO
T
4'
0"
TO
S
LO
T
4'
0"
4'
0"
TO
B
UT
TO
N
X= 3'
- 8
2'
6"
6'
2"
3'-0"
RE
AC
H
4'
0"
FO
RW
AR
D
RE
AC
H
4'
0"
FO
RW
AR
D
M
IN
1'
3" 4'
0" M
AX
ALLOWABL
E REACH
RANGE
FROM
FRONT
APPROACH
SANITARY
NAPKIN
DISPOSAL
SANITARY
NAPKIN
DISPENSER
SURFACE
MOUNTED
SOAP
DISPENSER
TOILET SEAT
COVER
DISPENSER
PAPER
TOWEL
DISPENSER
WALL
MOUNTED
DIAPER
CHANGING
STATION
HAND
DRYER
MIRROR
ABOVE
COUNTER/
LAVATORY
TOWEL
BAR
COAT HOOK
AT
RESTROOMS
NOTE: ALL MAXIMUM MOUNTING HEIGHTS TO BE
TAKEN FROM FINISH FLOOR TO HIGHEST
OPERABLE PART (COIN SLOTS, HANDLES, ETC. OF
ACCESSORY)
HO
LD
4'
0" A.
F.
F.
U.
N.
O
2'
0" A.
F.
F.
U.
N.
O
3'
6" A.
F.
F.
TYPICAL OUTLETS
MOUNTED BELOW
CREDENZA/
COUNTER U.N.O.
COUNTER/CREDENZA
@ 30"-36" U.N.O.
TYPICAL OUTLETS
MOUNTED ABOVE
CREDENZA /COUNTER
U.N.O.- MOUNT
HORIZONTALLY
COAT HOOKS WHERE
SCHED. U.N.O.
SCHEDULED
LATCHSET OR
LOCKSET U.N.O.
FIRE ALARM STROBE
WALL PHONE
THERMOSTATS, INTERCOMS,
CARD READERS OR OTHER
TYPES OF SWITCHES THAT
DO NOT FIT UNDER THE
SAME COVER PLATE AS THE
LIGHT SWITCHES
WALL LIGHT SWITCH OR
MOTION DETECTOR- IF
MORE THAN ONE
SWITCH, PLACE THEM
ALL UNDER ONE
COVERPLATE
TYPICAL OUTLET
MOUNTING HEIGHT
ALIGN WHERE
SCHEDULED DATA/
VOICE OUTLET OCCUR
4'
0" A.
F.
F.
3'
5/
6" A.
F.
F.
A.
F.
F.
1'
6"
6"
ELECTRICAL, VOICE, AND DATA WALL OUTLETS
SHALL BE GANGED TOGETHER AS TIGHT AS
POSSIBLE AS PER CODE RESTRICTIONS.
MOUNTING HEIGHTS, LOCATIONS AND ALIGNMENT
OF ALL DEVICES SHALL BE PER THIS DRAWING UNO.
6'
0" A.
F.
F.
M
IN
4'
0" M
AX
A
.F .F
HALL LANTERN
FIXUTRE, VISUAL
ELEMENTS SHALL BE 2
1/2" MIN. IN THE
SMALLEST DIMENSION
CALL BUTTONS FIXTURE,
VISUAL ELEMENTS SHALL
BE 3/4" MIN. IN THE
SMALLEST DIMENSION.
HA
ND
LE
O
R
BR
AC
KE
T
4'
0" A
.F .F
TO
P O
F
M
IN
1'
3" A.
F.
F.
M
AX
4'
0" A.
F.
F.
NOTE: FIRE EXTINGUISHER
CANNOT PROTRUDE MORE THAN
4"
0' - 8"
WALL
MOUNTE
D
SIGNAGE
PLAQUE
MEN
" A
.F .F
. M
AX
" A
.F .F
. M
IN
TACTILE CHARACTERS ON SIGNS SHALL BE
LOCATED 48" A.F.F. MIN MEASURED FROM THE
BASELINE OF THE LOWEST TACTILE CHARACTER
AND 60" A.F.F. MAX MEASURED FROM THE
BASELINE OF THE HIGHEST TACTILE CHARACTER.
ADA SIGNAGE FIRE PROTECTION TYPICAL ELEVATOR
PULL
STATION
FIRE
EXTINGUISHER
CABINET OR
BRACKET
control wall seat wall back wall
608.3.1 Grab Bars for Transfer Type Showers
LC LC
LC
48 min m in
6control wall back wall seat wall
Note: inside finished dimensions measured at the center points of opposing sides.
608.2.1 Transfer Type Shower Compartment Size and Clearance.
LC
m in
15 max m a x side wall
608.5.1 Transfer Type
Shower Compartment
Control Location
15-16
380-405
560-585 22-23
-1
5-
(a) size
2½ max
½ m a x seat wall wall seat
(b) distance from wall
610.3.2 L-Shaped Shower Seat
m in
1½ min
(a) projecting objects
(b) recessed objects
609.3 Spacing of Grab Bars
12 min
12 min
X < 4
405.9.2 Curb or Barrier Edge Protection405.9.2 Curb or Barrier Edge Protection
SHEET NUMBER
SHEET TITLE
CLIENT
ARCHITECT
CONSULTANT
PROJECT NAME
PROJECT LOCATION
PROJECT NUMBER
561-988-4002 www.pgal.com
Suite 400
791 Park of Commerce Boulevard
PGAL, Inc.
Boca Raton, FL 33487
Chenmoore and Associates
500 Australian Avenue
Suite 850
West Palm Beach, FL 33401
T 561-746-6900
F
IL
E N
A M
E
D A
T E
S T
A M
P
Johnson Structural Group
160 West Camino Real
Suite 1000
Boca Raton, FL 33432
T 561-982-8999
REGISTRATION
DRAWING HISTORY
CMTA
4 Harvard Circle
Suite 600
West Palm Beach, FL 33409
T 561-547-0598
C
R e v it L o c a ls
\P A
R I
II
R a m ila n iA
R S
D
.r v t
/1
/2
:4
:2
A
M
G0.10
ADA STANDARDS
Par III Restroom Renovation
2345 South Ocean Blvd Palm Beach, FL 33480
1008335.00
Town of Palm Beach Palm Beach Par III Golf Course
T 561-547-0598
Copyright © 2025
2345 South Ocean Blvd Palm Beach, FL 33480
NOTE: TYPICAL DETAILS OR CONDITIONS
PER FLORIDA BUILDING CODE.
CHAPTER 3: BUILDING BLOCKS
CHAPTER 4: ACCESSIBLE ROUTES
CHAPTER 6: PLUMBING ELEMENTS AND FACILITIESCHAPTER 5: GENERAL SITE AND BUILDING ELEMENTS
TYPICAL INSTALLATION HEIGHTS
302 - Floor or Ground Surfaces1
302 Floor or Ground Surfaces
304 305 306 Clearance Space 307 Limits of Protruding Objects1 308 Reach Ranges1
403.5.1 Clear Width of an Accessible Route1
403.5.2 Clear Width at Turn1
404 Doors, Doorways, and Gates1
404.2.6 Doors in Series and Gates in Series405.7 Ramp Landings1
Stair Nosings Handrail Height Handrail Clearance
505.7.2 Handrail Non-Circular Cross Section1505.10 Hardrails Extensions1
603 Toilet and Bathing Rooms1608 Showers1
Spacing of Grab Bars
405.9 Extended Floor or Ground Surface
A 2026/03/19 BID SET
39 SF
UNISEX
RESTROOM
12 SF
JANITORS
CLOSET
48 SF
MENS ADA
RESTROOM
48 SF
WOMENS ADA
RESTROOM
TRAVEL DIST ALLOWED: 200 FT
TRAVEL DIST: 23'-8"
CLEAR WIDTH
4' - 11"
SHEET NUMBER
SHEET TITLE
CLIENT
ARCHITECT
CONSULTANT
PROJECT NAME
PROJECT LOCATION
PROJECT NUMBER
561-988-4002 www.pgal.com
Suite 400
791 Park of Commerce Boulevard
PGAL, Inc.
Boca Raton, FL 33487
Chenmoore and Associates
500 Australian Avenue
Suite 850
West Palm Beach, FL 33401
T 561-746-6900
F
IL
E N
A M
E
D A
T E
S T
A M
P
Johnson Structural Group
160 West Camino Real
Suite 1000
Boca Raton, FL 33432
T 561-982-8999
REGISTRATION
DRAWING HISTORY
CMTA
4 Harvard Circle
Suite 600
West Palm Beach, FL 33409
T 561-547-0598
C
R e v it L o c a ls
\P A
R I
II
R a m ila n iA
R S
D
.r v t
/1
/2
:4
:2
A
M
G1.01
CODE ANALYSIS -
LIFE SAFETY PLAN
Par III Restroom Renovation
2345 South Ocean Blvd Palm Beach, FL 33480
1008335.00
Town of Palm Beach Palm Beach Par III Golf Course
T 561-547-0598
Copyright © 2025
2345 South Ocean Blvd Palm Beach, FL 33480
SCALE : 1/4" = 1'-0"
LIFE SAFETY PLAN
NOTE:
EXTERIOR BEARING WALLS SHALL NOT HAVE A FIRE RESISTANCE RATING LESS THAN THE REQUIRED RATINGS PER TABLE 602.
ROOF CONSTRCUTION AND ASSOCIATED SECONDARY
STRUCTURAL MEMEBERS
0 HR
FLOOR CONSTRUCTIONND ASSOCIATED SECONDARY
STRUCTURAL MEMEBERS
0 HR
NON-BEARING INTERIOR 0 HR
NON-BEARING EXTERIOR 0 HR
BEARING WALL INTERIOR (TOP FLOOR) 0 HR
BEARING WALL INTERIOR (TYP. FLOOR) 0 HR
BEARING WALL EXTERIOR 0 HR
STRUCTURAL FRAME 0 HR
BUILDING ELEMENT FIRE RATING
TYPE:VB PER TABLE 601
BUILDING TYPE OF CONSTRUCTION
NFPA 70 NATIONAL ELECTRICAL CODE 2020 EDITION
NATIONAL FIRE PROTECTION ASSOCIATION STANDARDS
FLORIDA ACCESSIBILITY CODE 2024- 8TH EDITION
FLORIDA PLUMBING CODE 2024- 8TH EDITION
FLORIDA MECHANICAL CODE 2024- 8TH EDITION
FLORIDA ENERGY CONSERVATION CODE 2024- 8TH EDITION
FLORIDA FIRE PREVENTION CODE 2024- 8TH EDITION
FLORIDA BUILDING CODE 2024- 8TH EDITION
APPLICABLE CODES
PROJECT SUMMARY DATA
THE TOWN OF PALM BEACH PAR 3 RESTROOM RENOVATION INVOLVES INTERIOR AND EXTERIOR UPGRADES TO THE RESTROOM FACILITY AT 2345 SOUTH OCEAN BOULEVARD. PREVIOUSLY, THE RESTROOMS WERE ACCESSIBLE ONLY FROM INSIDE THE BUILDING, WITH SEPARATE MEN’S AND WOMEN’S ENTRANCES. UNDER THIS RENOVATION, THAT INTERIOR ACCESS WILL BE REMOVED, AND A NEW ENTRANCE WILL BE
CREATED FROM THE WEST SIDE OF THE BUILDING, ALLOWING DIRECT OUTSIDE ACCESS.
THE NEW LAYOUT WILL FEATURE ADA-COMPLIANT RESTROOMS FOR WOMEN AND MEN, A UNISEX RESTROOM, AND A JANITOR’S CLOSET.
MODIFICATIONS TO THE MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS WILL BE MADE TO ACCOMMODATE THE NEW LAYOUT. THE TOTAL RENOVATION AREA IS APPROXIMATELY 302 SQUARE FEET, AND ALL IMPROVEMENTS WILL COMPLY WITH THE 2024 FLORIDA BUILDING
CODE AND LOCAL STANDARDS.
PROJECT DESCRIPTION & NARRATIVE
TOTAL OCCUPANT LOAD 1 HR
ASSEMBLY 232 SF 11 22
FUNCTION OF SPACE SQUARE FOOTAGE OCCUPANT LOAD... OCCUPANT LOAD
OCCUPANT LOAD CALCULATIONS - PER FBC 1004.5 & FFPC 101 TABLE 7.3.1.2
PROVIDED 3 3
EXISTING
PROVIDED
REQUIRED 11/75 = 1 11/75 = 1 1 1 1
ASSEMBLY
1 PER 75 FOR THE FIRST
1,500 AND 1 PER 120 FOR
THE REMAINDER
EXCEEDING 1,500
1 PER 40 FOR THE FIRST
1,520 AND 1 PER 60 FOR
THE REMAINDER
EXCEEDING 1,520
1 PER 200 1 PER 150 1 PER 1,000
MALE FEMALE MALE FEMALE
CLASSIFICATION OCCUPANCY
WATER CLOSETS LAVATORIES DRINKING
FOUNTAIN
SERVICE
SINK
PER FLORIDA PLUMBING CODE TABLE 403.1
PLUMBING CALCULATIONS
MAXIMUM COMMON PATH OF TRAVEL 75 FT NOT TO EXCEED 75 FT
MAXIMUM TRAVEL DISTANCE 200 FT NOT TO EXCEED 200 FT
ALLOWED PROVIDED
ALLOWABLE TRAVEL DISTANCES AND DEAD ENDS - PER FBC TABLE 1017.2, 1006.2, 1006.3.3(2), & 1020.5, AS WELL AS FFPC 101 TABLE...
A - "ASSEMBLY" 36 INCHES 5 FT ( 60 INCHES)
OCCUPANCY MIN. REQUIRED MIN. PROVIDED
CORRIDOR WIDTH - PER FBC 1005.3.2. & 1020.3
CLEAR WIDTH 32 INCHES 34 INCHES
MIN. REQUIRED MIN. PROVIDED
DOOR WIDTH - PER FBC 1005.3.2. & 1010.1
EGRESS REEQUIREMENTS
10"
8"
8"20.00'
27.00'
11.50'3.30'
29.00'
3.30'
11.50'
27.00'
20.00'
3.65'
12.00'
3.65'
12"
RIM=7.40'
N.INV=5.43'(4"PVC)
BOTTOM=5.35'
1 STORY CBS
FINISH FLOOR ELEVATION=8.47'
8"
24"
RIM=7.86'
UNABLE TO OPEN
BURIED
TOWN OF PALM BEACH
2345 S OCEAN BLVD
50-43-44-11-03-000-1321
ORB 2182, PAGE 902
N O
T A
P A
R T
O F
T H
IS
S
U R
V E
Y
8.45
8.35
8.35
8.45
W
ICV
ICV
ICV
ICV
RD N
YRD
RD N
YRD
R1 .5
0'
5.00'
6' HEDGE
TBM
ELEVATION=7.88'
SET MAG NAIL &
DISC "EGI TRAV"
COLUMN (TYP)
8' H E
D G
E
8' CHAIN LINK FENCE
ASPHALT
AREA
PLAN
TER
COVERED AREA
HANDRAIL
STEP
A/C
PAD
GRAVEL AREA
ASTROTURF DRIVING RANGE
GRAVEL AREA
TYPE "D" CURB
10' CONCRETE SIDEWALK
TYPE "D" CURB
5' HEDGE
TYPE "D" CURB
C
C
C
C C
E
E
9.
.3
.2
.2
.0
.66
.63
.70
.65
.2
.17
9.
9.
.3
.4
.0
.37
.30
9.
9.3 19.1
28.
8.
8.
8.
8.7
8.
8.
8.
9.
9.
8.
8.22
8.
9.
8.
8.1
8.71
9.82
.0
.0
9.
078.
8.3
8.
8.
8.
7.
8.
7.
7.
7.
7.
8.
8.
7.67
8.
8.
8.
8.
8.
8.76
8.278.
29 8.34
8.34
8.16
7.
8.308.
8.
8.
8.
8.
7.
7.9 18.
8.
7.
7.
7.1
9.
9.
8.
9.0
7.
7.
9.
9.
8.
8.
8.
7.
7.
8.
8.
398.
408.
8.1
7.
7.
8.
7.
7.96
7.99
8.347.85
8.14
7.
7.
8.
7.51
7.58
7.90
8.
7.
PROPOSED TYPE "D" CURB
PROPOSED TYPE "D" CURB
RELOCATED PEA ROCK
PROPOSED SIDEWALK
PROPOSED SIDEWALK
MATCH EXIST
SIDEWALK GRADE
MATCH EXIST
SIDEWALK GRADE
PROPOSED PEA ROCK
TRANSITION FROM TOP OF
CURB TO SIDEWALK GRADE
OVER A DISTANCE OF 1.5'
PROPOSED WHEEL STOP
PROPOSED RELOCATED
HOSE BIB
10"
8"
8"20.00'
27.00'
11.50'3.30'
29.00'
3.30'
11.50'
27.00'
20.00'
3.65'
12.00'
3.65'
12"
RIM=7.40'
N.INV=5.43'(4"PVC)
BOTTOM=5.35'
1 STORY CBS
FINISH FLOOR ELEVATION=8.47'
8"
24"
RIM=7.86'
UNABLE TO OPEN
BURIED
TOWN OF PALM BEACH
2345 S OCEAN BLVD
50-43-44-11-03-000-1321
ORB 2182, PAGE 902
N O
T A
P A
R T
O F
T H
IS
S
U R
V E
Y
W
ICV
ICV
ICV
ICV
RD N
YRD
RD N
YRD
6' HEDGE
TBM
ELEVATION=7.88'
SET MAG NAIL &
DISC "EGI TRAV"
COLUMN (TYP)
8' H E
D G
E
8' CHAIN LINK FENCE
ASPHALT
AREA
PLAN
TER
COVERED AREA
HANDRAIL
STEP
A/C
PAD
GRAVEL AREA
ASTROTURF DRIVING RANGE
GRAVEL AREA
TYPE "D" CURB
10' CONCRETE SIDEWALK
TYPE "D" CURB
5' HEDGE
TYPE "D" CURB
C
C
C
C C
E
E
.78
.3
.7
9.
9.
.3
.2
.2
.0
.66
.63
.70
.65
.2
.17
9.
9.
.3
.4
.0
.37
.30
9.
9.
319.1
28.
8.
8.
8.
8.7
8.
8.
8.
9.
9.
8.
8.22
8.
9.
8.
8.1
8.71
9.82
.0
.0
9.
078.
8.3
8.
8.
8.
7.
8.
7.
7.
7.
7.
8.
8.
7.67
8.0
8.
8.1
8.
8.
8.
8.76
8.278.
29 8.34
8.34
8.16
7.
8.308.
8.
8.
8.
8.
7.
7.9 18.
8.
7.9
7.
7.1
9.
9.
8.
9.0
7.
7.
9.
9.
8.
8.
8.
7.
7.
8.
8.
398.
408.
8.1
7.
7.
8.
7.
7.96 7.99
8.347.85
8.14
7.
7.
8.
7.51
7.58
7.90
8.
7.
REMOVE AND RELOCATE PEA ROCK
AS REQUIRED. CONTRACTOR TO
COORDINATE WITH OWNER FOR
FINAL PLACEMENT.
REMOVE SIDEWALK
SAW CUT CLEAN EDGE
REMOVE SIDEWALK
REMOVE TYPE
"D" CURB
REMOVE SIDEWALK
RELOCATE EXIST
HOSE BIB
REMOVE HEDGE
THIS DOCUMENT IS RELEASED
FOR INTERIM REVIEW UNDER
THE AUTHORITY OF
NOT FOR REGULATORY
APPROVAL, BIDDING, PERMIT,
OR CONSTRUCTION PURPOSES.
INTERIM REVIEW
SHEET NUMBER
SHEET TITLE
CLIENT
ARCHITECT
CONSULTANT
PROJECT NAME
PROJECT LOCATION
PROJECT NUMBER
561-988-4002 www.pgal.com
Suite 400
791 Park of Commerce Boulevard
PGAL, Inc.
Boca Raton, FL 33487
NAME HERE, ARCHITECT
TEXAS REG. NO. #####
Johnson Structural Group
160 West Camino Real Suite 1000 Boca Raton, FL 33432 T 561-982-8999
REGISTRATION
DRAWING HISTORY
CMTA
2 Harvard Circle Suite 100 West Palm Beach, FL 33409 T 561-547-0598
Par III Restroom Renovation
2345 South Ocean Blvd Palm Beach, FL 33480
1008335.00
Palm Beach Par III Golf Course
T 561-547-0598
Copyright © 2025
2345 South Ocean Blvd Palm Beach, FL 33480
№. DATE DESCRIPTION
500 Australian Avenue South Suite 850
West Palm Beach, FL 33401 561.746.6900 www.chenmoore.com
D A
TE
S
TA
M
P:
/2 9/
:2
4:
P M
FI
LE
N A
M E:
V :\P ro je ct s\
\2 5-
.0 pa r 3 re st ro om re no va tio n\
D es ig n\
C A
D \S he et s
1 INCH = FEET
GRAPHIC SCALE
5 10 20
C1.00
CIVIL IMPROVEMENTS
SURFACE FLOW ARROW
PROPOSED CONCRETE
00.00 PROPOSED PAVEMENT ELEVATION
PROPOSED LEGEND
EXISTING ELEVATION00
.0
PAVING, GRADING AND DRAINAGE NOTES:
1. ALL SIDEWALKS SHALL MEET ALL A.D.A. REQUIREMENTS (5% MAX.
LONGITUDINAL SLOPE AND 2% MAX. TRANSVERSE SLOPE).
2. CONTRACTOR TO PROVIDE DETAILED AS-BUILTS SURVEYS THAT
CLEARLY DEFINE THE AREAS OF WORK COMPLETED UNDER THIS
CONTRACT.
FINISHED
GRADE
8"
6"
ASPHALT
4" CURB PAD
COMPACTED TO 98%
AASHTO T-180 (LBR40)
2" R.
6"
NOTE
LIMEROCK
SUBGRADE
4" CURB PAD
COMPACTED TO 98%
AASHTO T-180 (LBR40)
4 "R.
6"
3,000 PSI CONCRETE
CONCRETE
PAVEMENT
JOINT SEAL
12" EXP. JOINT AND
PREFORMED JOINT FLLER
LIMEROCK
SUBGRADE
3,000 PSI CONCRETE
REFER TO FDOT INDEX NO. 520-001
FOR ADDITIONAL INFORMATION.6"
FINISHED
GRADE
8"
6"
2" R.
6"
TYPE 'D' CONCRETE CURB
N.T.S.
DATE: __________01/29/2026
LICENSE NO. 98606
Bradley L. Childers, P.E.
NOTES:
1. ALL JOINTS ARE TO BE SAW CUT
PROP. SP-9.5 VARYING DEPTH (MAX LIFT 1.5")
EXIST LIMEROCK BASE
EXIST COMPACTED SUBGRADE
EXIST. ASPHALT
PROPOSED ASPHALT OVERLAY
N.T.S.
4"
PROPOSED SIDEWALK
N.T.S.
TYPE 'D' CONCRETE CURB
COMPACTED BASE
NOTES:
1. SIDEWALKS TO BE 4'' THICK PORTLAND CEMENT CONCRETE, MIN. 3000 P.S.I.@ 28 DAYS
2. BASE TO BE A MINIMUM 4 INCHES OF CLEAN SAND OR SANDY LOAM, COMPACTED TO 98% OF MAXIMUM DRY
DENSITY PER AASHTO T-180 WITH MIN LBR 40, FULL WIDTH.
3. SIDEWALKS TO BE BROOM FINISHED WITH EVEN, DUSTLESS SURFACE.
4. SIDEWALK THICKNESS TO BE 6 INCHES MINIMUM IN ALL AREAS SUBJECT TO VEHICULAR TRAFFIC.
5. EXPANSION MATERIAL IS TO BE FROM FDOT'S APPROVED PRODUCT LIST.
2% (MIN)
PROPOSED PEA ROCK
2'' EXPANSION MATERIAL
EXISTING FACE OF BUILDING
PROPOSED GRADECONCRETE SIDEWALK
6"
12"±
6'
3" Max.
2" Min.5" Min.
6" Max.
Cast or rubbed (Typ.)
4" Min.
5" Max.
5 8"or 3 4"holes
1 4"Pitch optional
2" Min.
3" Max.
# 4 Bars, 18" long (two per guard)
2" R (Typ)
PROPOSED WHEEL STOP
N.T.S.
NOTES:
1. ULTIMATE STRENGTH OF CONCRETE FOR CURBS AND WHEEL STOPS SHALL BE 2,500 PSI. @ 28 DAYS
2. 1/8" - 1/4" CONTRACTION JOINTS IN CURBS SHALL BE 3 1/2" MIN. DEPTH (AS MEASURED) FROM TOP OF ADJACENT
PAVEMENT) AND AT 10-FOOT CENTERS. NO SECTION SHALL BE LESS THAN 4 FEET.
3. WHEN PAVEMENT IS CONCRETE, PROVIDE A 1/2" EXPANSION JOINT WITH PRE-FORMED JOINT FILLER AND JOINT SEAL BETWEEN CURB AND CONCRETE PAVEMENT (1 1/2" TAPER ON CURB FACE NOT NOT REQUIRED AT
CONCRETE PAVEMENT).
4. ENDS OF TYPE "B" AND "D" CURB SHALL TRANSITION FROM FULL HEIGHT TO ZERO IN 3 FEET.
GENERAL NOTES:
1. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS, WHETHER SHOWN
OR NOT, AND NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO
CONSTRUCTION.
2. THE HORIZONTAL AND VERTICAL LOCATIONS OF THE EXISTING UTILITIES
SHOWN ARE APPROXIMATE ONLY AND ARE BASED ON FIELD
OBSERVATION AND/OR AVAILABLE PLANS. THE EXACT LOCATION MAY
VARY. IF UPON EXCAVATION, AN EXISTING UTILITY IS FOUND TO BE IN
CONFLICT WITH THE PROPOSED CONSTRUCTION OR TO BE OF A SIZE OR
MATERIAL DIFFERENT FROM THAT SHOWN ON THE PLANS THE
CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF RECORD.
3. ANY EXISTING ITEM DISTURBED DURING CONSTRUCTION IS TO BE
RESTORED TO EQUAL OR BETTER QUALITY.
4. PAVEMENT RESTORATION IS TO MATCH EXISTING GRADE UNLESS
OTHERWISE NOTED.
5. IT SHALL BE THE CONTRACTOR'S SOLE RESPONSIBILITY TO TAKE THE
NECESSARY PRECAUTIONS TO ENSURE PROPER SAFETY AND
WORKMANSHIP WHEN WORKING IN THE VICINITY OF EXISTING UTILITY
LINES.
6. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH FPL ON
ANY WORK IN THE VICINITY OF OVERHEAD OR UNDERGROUND POWER
LINES.
7. CONTRACTOR SHALL VERIFY PROPER CLEARANCE BELOW EXISTING
OVERHEAD POWER LINES PRIOR TO WORKING WITHIN THE VICINITY OF
POWER LINES.
REMOVE MATERIAL FROM AREA
RESTORATION AREA
REMOVE ITEM
DEMOLITION NOTES:
1. DEMOLITION TO START AFTER NOTICE TO PROCEED FOR CONSTRUCTION
(NTP) HAS BEEN ISSUED BY THE TOWN OF PALM BEACH (TOPB).
2. GENERAL CONTRACTOR IS TO SECURE AND MAINTAIN TOPB PERMIT.
INSPECTIONS CONSIDERED UNDER THE PERMIT MUST BE COORDINATED
WITH PLANNING ZONING AND BUILDING DEPARTMENT.
3. DO NOT START DEMOLITION WORK UNTIL UTILITY DISCONNECTING AND
SEALING HAVE BEEN COMPLETED AND VERIFIED IN WRITING.
4. BEFORE PROCEEDING WITH DEMOLITION OPERATIONS THE CONTRACTOR
IS TO DRAIN, PURGE, OR OTHERWISE REMOVE, COLLECT, AND DISPOSE
OF CHEMICALS, GASES, EXPLOSIVES, ACIDS, FLAMMABLES, OR OTHER
DANGEROUS MATERIALS.
5. CONDUCT DEMOLITION OPERATIONS AND REMOVE DEBRIS TO ENSURE
MINIMUM INTERFERENCE WITH ROADS, STREETS, WALKS, AND OTHER
ADJACENT OCCUPIED AND USED FACILITIES.
6. DO NOT CLOSE OR OBSTRUCT STREETS, WALKS, OR OTHER ADJACENT
OCCUPIED OR IN-USE FACILITIES WITHOUT PERMISSION FROM OWNER,
THE TRIBE AND AUTHORITIES HAVING JURISDICTION. PROVIDE
ALTERNATE ROUTES AROUND CLOSED OR OBSTRUCTED TRAFFIC WAYS
AS REQUIRED BY GOVERNING REGULATIONS.
7. CONDUCT DEMOLITION OPERATIONS TO PREVENT INJURY TO PEOPLE
AND DAMAGE TO ADJACENT BUILDINGS AND FACILITIES TO REMAIN.
ENSURE SAFE PASSAGE OF PEOPLE AROUND DEMOLITION AREA.
8. ERECT TEMPORARY PROTECTION, SUCH AS WALKS, FENCES, BARRIERS,
RAILINGS, ETC. WHERE REQUIRED BY AUTHORITIES HAVING
JURISDICTION.
9. PROTECT EXISTING SITE IMPROVEMENTS, APPURTENANCES, AND
LANDSCAPING TO REMAIN.
10. ADJACENT IMPROVEMENTS SHALL BE CLEANED OF DUST, DIRT, AND
DEBRIS CAUSED BY DEMOLITION OPERATIONS. RETURN ADJACENT
AREAS TO CONDITION EXISTING BEFORE START OF DEMOLITION.
11. FOR SELECTIVE DEMOLITION, USE CUTTING METHODS LEAST LIKELY TO
DAMAGE CONSTRUCTION TO REMAIN OR ADJOINING CONSTRUCTION. TO
MINIMIZE DISTURBANCE OF ADJACENT SURFACES, USE HAND OR SMALL
POWER TOOLS DESIGNED FOR SAWING OR GRINDING, NOT HAMMERING
OR CHOPPING. TEMPORARILY COVER OPENINGS TO REMAIN
12. DEMOLISH CONCRETE IN SMALL SECTIONS. CUT CONCRETE AT
JUNCTURES WITH CONSTRUCTION TO REMAIN, USING POWER-DRIVEN
MASONRY SAW OR HAND TOOLS; DO NOT USE POWER-DRIVEN IMPACT
TOOLS.
13. INFORMATION SHOWN ON THE DRAWINGS AS TO THE LOCATION OF
EXISTING UTILITIES HAS BEEN PREPARED FROM THE MOST RELIABLE
DATA AVAILABLE TO THE ENGINEER; HOWEVER, THIS INFORMATION IS
NOT GUARANTEED. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
DETERMINE THE LOCATION, CHARACTER, AND DEPTH OF ALL EXISTING
UTILITIES. THE CONTRACTOR SHALL ASSIST THE UTILITY COMPANIES, BY
EVERY MEANS POSSIBLE, TO DETERMINE SAID LOCATIONS AND THE
LOCATIONS OF RECENT ADDITIONS TO THE SYSTEMS NOT SHOWN.
14. REMOVAL, DEMOLITION, HAULING, AND DISPOSAL SHALL COMPLY WITH
REGULATIONS BY F.D.E.P., E.P.A., AND ANY OTHER AUTHORITY HAVING
JURISDICTION.
15. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION AND
REQUIREMENTS.
16. ALL EXISTING STREET LIGHTING WILL REMAIN IN PLACE AND REMAIN IN
SERVICE DURING CONSTRUCTION OPERATIONS.
EXISTING CONDITIONS NOTES:
1. EXISTING CONDITIONS PRESENTED ARE BASED ON A TOPOGRAPHIC
SURVEY PROVIDED BY ENGENUITY GROUP INC., PROJECT 25029.01, DATED
06/12/2025. ADDITIONAL INFORMATION WAS OBTAINED FROM AS-BUILTS
AND RECORD DRAWINGS PROVIDED BY UTILITY COMPANIES, G.I.S.
INFORMATION AND FIELD VISITS.
2. ALL ELEVATIONS ARE BASED ON THE NORTH AMERICAN VERTICAL
DATUM OF 1988 (NAVD 88).
3. NATIONAL GEODETIC SURVEY (NGS) BENCHMARK USED:
DESCRIPTION = 06 78 E 07
ELEVATION = 14.99' NAVD 88
4. CONTRACTOR IS TO PROTECT ALL EXISTING TREES, SIGNS, AND ABOVE
GROUND UTILITIES NOT IMPACTED BY THIS PLAN.
YARD DRAIN
LIGHT POLE
ICV IRRIGATION CONTROL VALVE
BRICK PAVERS
C
ORNAMENTAL TREE AND SIZE
COCONUT PALM AND SIZE
CONCRETE
ORB OFFICIAL RECORD BOOK
WIRE PULL BOX- ELECTRIC
TEMPORARY BENCHMARK
MEASURED ELEVATIONx 0.0
W WATER VALVE
SANITARY VALVE
PVC/HDPE
DRN UNDERGROUND STORM
INFORMATION SIGN (SINGLE POST)
CHAIN LINK FENCE
PLASTIC PIPE
E
S
10"
10"
RD N
YRD
INVERTINV
AIR CONDITIONINGA/C
CONCRETE BLOCK STRUCTURECBS
TYPICALTYP
EXISTING AND DEMOLITION PLAN
PAVING AND GRADING PLAN
DEMOLITION LEGEND EXISTING LEGEND
DRAWING HISTORY
№. DATE DESCRIPTION
A 2026/02/23 BID SET
№. DATE DESCRIPTION
A 2026/03/10 BID SET
amilani Rectangle amilani Snapshot
10"
8"20.00'
27.00'
11.50'3.30'
29.00'
3.30'
11.50'
27.00'
20.00'
3.65'
12.00'
3.65'
12"
RIM=7.40'
N.INV=5.43'(4"PVC)
BOTTOM=5.35'
1 STORY CBS
FINISH FLOOR ELEVATION=8.47'
8"
24"
RIM=7.86'
UNABLE TO OPEN
BURIED
TOWN OF PALM BEACH
2345 S OCEAN BLVD
50-43-44-11-03-000-1321
ORB 2182, PAGE 902
NOT A PART OF THIS SURVEY
N O
T A
P A
R T
O F
T H
IS
S
U R
V E
Y
S
W
ICV
ICV
ICV
ICV
RD N
YRD
RD N
YRD
W
APPROXIMATE LOCATION OF
EXISTING 1 1
2" WATER METER
S O
C E
A N
B
LV
D
6' HEDGE
TBM
ELEVATION=7.88'
SET MAG NAIL &
DISC "EGI TRAV"
TBM
ELEVATION=8.39'
SET MAG NAIL &
DISC "EGI TRAV"
COLUMN (TYP)
8' H E
D G
E
8' CHAIN LINK FENCE
ASPHALT
AREA
PLAN
TER
COVERED AREA
HANDRAIL
STEP
A/C
PAD
GRAVEL AREA
ASTROTURF DRIVING RANGE
GRAVEL AREA
TYPE "D" CURB
10' CONCRETE SIDEWALK
TYPE "D" CURB
ASPHALT PARKING LOT
5' HEDGE
TYPE "D" CURB
APPROXIMATE LOCATION OF
EXISTING PALMS (TYP)
TRENCH RESTORATION, PLACE
ASPHALT
ABANDON 1 12"
WATER SERVICE
IN PLACE
CONTRACTOR TO LOCATE
AND CONNECT TO EXISTING
BUILDING SERVICE
C
C
C
C C
E
E
9.
.3
.2
.2
.0
.66
.63
.70
.65
.2
.17
9.
9.
.3
.4
.0
.37
.30
9.
9.
319.1
28.
8.
8.
8.
8.7
8.
8.
8.
9.
9.
8.
8.22
8.
9.
8.
8.
8.71
9.82
.0
.0
9.
078.
8.3
8.
8.
8.
7.
8.
7.
7.
7.
7.
8.
8.
7.67
8.
8.1
8.
8.
8.
8.76
8.278.
29 8.34
8.34
8.16
7.
8.308.
8.
8.
8.
8.
7.
7.9 18.
8.
7.9
7.
7.1
9.
9.
8.
9.0
7.
7.
7.
8.
8.
9.
9.
9.
9.
8.
8.
8.
7.
7.
8.
8.
398.
408.
8.1
7.
7.
8.
7.
7.96 7.99
8.347.85
8.14
7.
7.
8.
7.51
7.58
7.90
8.
7.
EXISTING WATER
SERVICE LINE
V
CONTRACTOR TO ADJUST ROUTE OF PROPOSED
2" WATER SERVICE TO AVOID VEGETATION
REMOVE EXISTING 1"
BACKFLOW PREVENTOR
AND REPLACE WITH 1-1/2"
BACKFLOW PREVENTOR
W W W W W W W W W W W
PROP 2" WATER
SERVICE LINE
REFURBISH PARKING
STALLS AFFECTED BY
TRENCH RESTORATION
THIS DOCUMENT IS RELEASED
FOR INTERIM REVIEW UNDER
THE AUTHORITY OF
NOT FOR REGULATORY
APPROVAL, BIDDING, PERMIT,
OR CONSTRUCTION PURPOSES.
INTERIM REVIEW
SHEET NUMBER
SHEET TITLE
CLIENT
ARCHITECT
CONSULTANT
PROJECT NAME
PROJECT LOCATION
PROJECT NUMBER
561-988-4002 www.pgal.com
Suite 400
791 Park of Commerce Boulevard
PGAL, Inc.
Boca Raton, FL 33487
NAME HERE, ARCHITECT
TEXAS REG. NO. #####
Johnson Structural Group
160 West Camino Real Suite 1000 Boca Raton, FL 33432 T 561-982-8999
REGISTRATION
DRAWING HISTORY
CMTA
2 Harvard Circle Suite 100 West Palm Beach, FL 33409 T 561-547-0598
Par III Restroom Renovation
2345 South Ocean Blvd Palm Beach, FL 33480
1008335.00
Palm Beach Par III Golf Course
T 561-547-0598
Copyright © 2025
2345 South Ocean Blvd Palm Beach, FL 33480
№. DATE DESCRIPTION
500 Australian Avenue South Suite 850
West Palm Beach, FL 33401 561.746.6900 www.chenmoore.com
D A
TE
S
TA
M
P:
/2 9/
:3
4:
P M
FI
LE
N A
M E:
V :\P ro je ct s\
\2 5-
.0 pa r 3 re st ro om re no va tio n\
D es ig n\
C A
D \S he et s
1 INCH = FEET
GRAPHIC SCALE
5 10 20
C2.00
UTILITY
IMPROVEMENTS
DATE: __________01/29/2026
LICENSE NO. 98606
Bradley L. Childers, P.E.
WATER NOTES:
1. CONTRACTOR SHALL PLAN ALL UTILITY CROSSINGS TO CONFIRM
HORIZONTAL AND VERTICAL SEPARATIONS PRIOR TO CONSTRUCTION.
2. WATER LINES SHALL BE LAID WITH A MINIMUM SIX (6) FOOT LATERAL
SEPARATION FROM OBSTRUCTIONS (I.E. CULVERTS, STRUCTURES, ETC.)
AND A MINIMUM TEN (10) FOOT CLEARANCE FROM TREES.
3. WATER MAIN SHALL CROSS OVER DRAINAGE & SEWER LINES UNLESS
OTHERWISE SPECIFIED ON PLAN. 10' MINIMUM HORIZONTAL CLEARANCE
IS REQUIRED BETWEEN WATER MAIN AND FORCE MAIN.
4. THE EXISTING WATER MAINS THAT ARE TO BE REMOVED SHALL REMAIN
ACTIVE UNTIL A CLEARANCE LETTER HAS BEEN ISSUED AND THE NEW
WATER MAINS ARE ACTIVATED.
5. CONTRACTOR TO PROVIDE DETAILED AS-BUILTS SURVEYS THAT
CLEARLY DEFINE THE AREAS OF WORK COMPLETED UNDER THIS
CONTRACT INCLUDING BUT NOT LIMITED TO TOP OF PIPE ELEVATION, TOP
OF ALL FITTINGS, ETC.
DRAWING HISTORY
№. DATE DESCRIPTION
A 2026/02/23 BID SET
№. DATE DESCRIPTION
A 2026/03/10 BID SET
amilani Rectangle amilani Snapshot
EQ EQ
GB1
36" GRAB BAR AND MOUNTING PLATE. STAINLESS STEEL, PER ADAAG AND UFAS.
PROVIDE APPROPRIATE BACKING, TYP. PROVIDE AT ALL ADA TOILETS TYP.
GB2
42" GRAB BAR AND MOUNTING PLATE. STAINLESS STEEL, PER ADAAG AND UFAS.
PROVIDE APPROPRIATE BACKING, TYP. PROVIDE AT ALL ADA TOILETS TYP.
ND
SANITARY NAPKIN DISPOSAL SURFACE MOUNTED, STAINLESS STEEL.
TP2
DOUBLE TOILET TISSUE
DISPENSER SURFACE
MOUNTED. BASIS OF DESIGN
BOBRICK B-2892.
CL
SR
HEAVY-DUTY SHOWER CURTAIN ROD (BROBICK B-207)
WITH CONCEALED MOUNTING. VINYL SHOWER
CURTAIN (BOBRICK 204-3) AND CURTAIN HOOKS
(BOBRICK 204-1). LOCATE AT ALL SHOWERS
MR1
24"W X 36"H MIRROR WITH SS CHANNEL
NOTE: MIRROR IS PLACED ABOVE LAV.
MR2
60"H X 24"W MIRROR WITH SS
CHANNEL
SHOWER CURTAIN
PROVIDED BY
CONTRACTOR
GRAB BAR & SHOWER CONTROL
MOUNTING HEIGHTS
CL
EWC-2
ELECTRIC WATER COOLER WITH
BOTTLE FILLER, WALL-MOUNTED. PAIR
WITH SINGLE COOLER WHERE
INDICATED ON PLUMBING PLANS.
SH1
ACCESSIBLE ROLL-IN SHOWER AND CLEAR SPACE. PROVIDE GRAB BARS AND FOLDABLE BENCH FB1 AT EACH LOCATION
BROBICK B-5181
GB3
24" GRAB BAR AND MOUNTING PLATE. STAINLESS STEEL, PER ADAAG AND UFAS. PROVIDE APPROPRIATE BACKING, TYP.
PER PLAN
3'- 0"
AB
O
VE
S
HO
W
ER
P
AN
6'- 8"
BACK WALL
SIDE
WALL
SHOWER
CONTROLS
COUNTER SINK, TYPICAL AT IN-CLASSROOM
CASEWORK. LAVATORY SHOULD BE
MOUNTED AT 2'-10" TO TOP OF
LAVATORY RIM
MAINTAIN 30" x 48" CLEAR
FLOOR AREA TYP.
2'
6"
4' - 0"
3'
0"
1' - 0" 2'
0"
3' - 0"
5' - 0"
5'
0"
5' - 0"
MAINTAIN CLEAR FLOOR
TURN AROUND AREA TYP.
1' - 6" 2' - 0"
6'
2"
MAINTAIN CLEAR CORRIDOR WIDTH
5'-0" (WITHOUT TURN-AROUND CLEAR
FLOOR AREA) OR 3'-8" (WITH TURN-
AROUND CLEAR FLOOR AREA)
M
IN
. C
LE
AR
5'
0"
TYPICAL PULL SIDE CLEARANCE TYPICAL PUSH SIDE CLEARANCE
M
IN
. C
LE
AR
5'
0"
SR
SHOWER CURTAIN ROD
6'
5/
8"
PROVIDE BACKING FOR
MIRRORS, ALL
LOCATIONS. WHERE
MIRROR IS PARTICALLY
MOUNTED OVER TILE,
PROVIDE CEDAR OR
PLASTIC SHIMS AND SEAL
GAP.
GENERAL NOTES
1. PROVIDE BLOCKING (FLAT STRAP OR BACKING STEEL PLATE) FOR WALL
MOUNTED ACCESSORIES. REFER TO PARTITION TYPES GENERAL NOTES.
2. HEIGHT DIMENSIONS TAKEN FROM FINISHED FLOOR.
3. ADA CLEARANCES AND TYPICAL DIMENSIONS REFLECT FINISH TO FINISH.
4. BLOCKING FOR THE FUTURE INSTALLATION OF GRAB BARS SHALL
EXTEND THE FULL LENGTH OF THE CODE REQUIRED GRAB BAR PLUS 3"
MINIMUM BEYOND THE CENTER OF THE POINT OF ATTACHMENT IN ALL
DIRECTIONS.
5. SEE PLUMBING DRAWINGS FOR SCHEDULE OF FIXTURES AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
6. SINGLE IN-CLASSROOM TOILET ROOMS ARE TO BE 18"A.F.F. TO TOP OF
T…